Upload
joneyang
View
217
Download
1
Embed Size (px)
DESCRIPTION
This EMC filter applies to analog circuit which is noise-sensitive. Put FC-L01DV1 on to the input of AC/DC module can ensure the module meet Surge level of IEC/EN61000-4-5 ±1KV (2Ω internal resistance)/±2KV (12Ω internal resistance)and EMI requirement of CISPR22 /EN 55022 Class B. EMC filter used with the MORNSUN AC/DC module, AC/DC module’s max. Input voltage must not more than EMC filter’s max. Voltage, AC/DC module’s max. Input current must less than EMC filter’s max current.
Citation preview
EMC Filter FC-L01DV1 Series
EMC Filter
RoHS
FEATURES Compact size
Design to suppress the AC power surge
to achieve primary protection
Ensure the power supply module to meet the
requirement of CISPR22/ EN55022 Class B
Cost-effective
Low Temperature rise
This EMC filter applies to analog circuit which is noise-sensitive. Put FC-L01DV1 on to the input of AC/DC module can ensure the
module meet Surge level of IEC/EN61000-4-5 ±1KV (2Ω internal resistance)/±2KV (12Ω internal resistance)and EMI requirement of
CISPR22 /EN 55022 Class B. EM C filter used with the MORNSUN AC/DC module, AC/DC module’s max. Input voltage must not more than EMC filter’s max.
Voltage, AC/DC module’s max. Input current must less than EM C filter ’s max current.
Selection Guide
Model Input Voltage Range (VAC) Current (A)(max)
FC-L01DV1 85~305 0.3
General Specifications Item Test Conditions Min. Typ. Max. Unit
Operating Temperature -40 -- 85
Storage Temperature -40 -- 105 °C
Casing Temperature Rise 220VAC @0.3A -- -- 30
Leakage current (line to ground) 2000VAC,tested for 1 minute -- 2 -- mA
General Specifications Casing Material Black flame-retardant heat-proof epoxy resin (UL94-V0)
Package Dimensions 33.70X22.20X18.00 mm
Weight 20g (Typ)
Devise Standard
Put FC-L01DV1 on to the input of AC/DC module can ensure the module meet Surge level of IEC/EN61000-4-5 ±1KV (2Ω internal
resistance)/±2KV (12Ω internal resistance)and EMI requirement of CISPR22 /EN 55022 Class B.
Design Reference
1. Inside schematic
1 LM 1
4 LM 2
IN(L) OUT(L)
2 CY1
MOV1
CX
1
CY2
IN(N) 2 3
OUT(N)
2014.09.10-A/2 Page 1 of 3 MORNSUN
Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation
EMC Filter FC-L01DV1 Series
2. Typical application
L
FUS E L
L
FUS E
L
IN(L) O UT( L)
+
+
IN(L) OUT(L) LS0 3-0 5BXXK
LS 01
C1
LS0 3-0 5BXXKC
+ 5 Vo O UTPU T
10
Vo
FC-L01DV1 LS 03 -R2
FC -L01D V1 OUTPUT
C1
+ LS0 3-0 5BXXSC
N
7 LS 05
N
LS0 3-05BBY7S
IN(N)
IN(N)
LS 03
-
-
O UT(N)
N
OUT(N)
N
CY0
CY
FUSE: Due to the difference of the power module input current, the fuse of the recommended values, please refer to the Technical
Manual for the power module. C1, CY0, CY, LDM: parameter selection please refer to power supply technical manual.
3. Supporting the product model
Model EMI(Without EMI(With FC- Surge (Without Surge (With FC- EFT (Without EFT (With FC-
External Circuit ) L01DV1) Externa l Circuit) L01DV1) Externa l Circuit) L01DV1)
LS01
CISPR22/EN55022 IEC/EN61000-4-5 IEC/EN61000 -4 -4
-- -- ±1KV/±2K V -- ±4KV Series CLASS B perf. Criteria B perf. Criteria B
LS03
--
CISPR22/EN55022
--
IEC/EN61000-4-5
--
IEC/EN61000 -4 -4
±1KV/±2K V ±4KV Series CLASS B
perf. Criteria B perf. Criteria B
LS03-R2
CISPR22/EN55022 IEC/EN61000-4-5 IEC/EN61000 -4 -4
-- -- ±1KV/±2K V -- ±4KV Series CLASS B perf. Criteria B perf. Criteria B
LS05
CISPR22/EN55022 IEC/EN61000-4-5 IEC/EN61000-4 -4
-- -- ±1KV/±2K V -- ±4KV Series CLASS B perf. Criteria B perf. Criteria B
CISPR22/EN55022
IEC/EN61000-4-5 IEC/EN61000 -4 -4
LS03-05BXXK -- -- ±1KV/±2K V -- ±4KV CLASS B perf. Criteria B perf. Criteria B
4. For more information Please find the application notes on www.mornsun-power.com
2014.09.10-A/2 Page 2 of 3 MORNSUN
Guangzhou Science & Technology Co.,
Ltd. reserves the copyright and right of final interpretation
EMC Filter FC-L01DV1 Series
FC-L01DV1 Dimensions and Recommended Layout
Note: 1. Packing Information please refer to 'Product Packing Information'. Packing bag number: 58220014;
2. Unless otherwise specified, data in this datasheet should be tested under the conditions of Ta=25°C, humidity<75%;
3. All index testing methods in this datasheet are based on our Company’s corporate standards;
4. The performance indexes of the product models listed in this manual are as above, but some indexes of non -standard model
products will exceed the above-mentioned requirements, and please directly contact our technicians for specific information; 5. We can provide product customization service;
6. Specifications of this product are subject to changes without prior notice.
MORNSUN Guangzhou Science & Technology Co., Ltd. Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Luogang District, Guangzhou, P. R.
China Tel: 86-20-38601850-8801 Fax: 86-20-38601272 E-mail: [email protected]
2014.09.10-A/2 Page 3 of 3 MORNSUN
Guangzhou Science & Technology Co., Ltd. reserves the copyright and r ight of final interpretation