3
EMC Filter FC-L01DV1 Series EMC Filter RoHS FEATURES Compact size Design to suppress the AC power surge to achieve primary protection Ensure the power supply module to meet the requirement of CISPR22/ EN55022 Class B Cost-effective Low Temperature rise This EMC filter applies to analog circuit which is noise-sensitive. Put FC-L01DV1 on to the input of AC/DC module can ensure the module meet Surge level of IEC/EN61000-4-5 ±1KV (2Ω internal resistance)/±2KV (12Ω internal resistance)and EMI requirement of CISPR22 /EN 55022 Class B. EM C filter used with the MORNSUN AC/DC module, AC/DC modules max. Input voltage must not more than EMC filters max. Voltage, AC/DC modules max. Input current must less than EM C filter s max current. Selection Guide Model Input Voltage Range (VAC) Current (A)(max) FC-L01DV1 85~305 0.3 General Specifications Item Test Conditions Min. Typ. Max. Unit Operating Temperature -40 -- 85 Storage Temperature -40 -- 105 °C Casing Temperature Rise 220VAC @0.3A -- -- 30 Leakage current (line to ground) 2000VACtested for 1 m inute -- 2 -- mA General Specifications Casing Material Black flame-retardant heat-proof epoxy resin (UL94-V0) Package Dimensions 33.70X22.20X18.00 m m Weight 20g (Typ) Devise Standard Put FC-L01DV1 on to the input of AC/DC module can ensure the module meet Surge level of IEC/EN61000-4-5 ±1KV (2Ω internal resistance)/±2KV (12Ω internal resistance)and EMI requirement of CISPR22 /EN 55022 Class B. Design Reference 1. Inside schematic 1 LM 1 4 LM 2 IN(L) OUT(L) 2 CY1 MOV1 CX 1 CY2 IN(N) 2 3 OUT(N) 2014.09.10-A/2 Page 1 of 3 MORNSUN Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation

EMC Filter FC-L01DV1 Series

Embed Size (px)

DESCRIPTION

This EMC filter applies to analog circuit which is noise-sensitive. Put FC-L01DV1 on to the input of AC/DC module can ensure the module meet Surge level of IEC/EN61000-4-5 ±1KV (2Ω internal resistance)/±2KV (12Ω internal resistance)and EMI requirement of CISPR22 /EN 55022 Class B. EMC filter used with the MORNSUN AC/DC module, AC/DC module’s max. Input voltage must not more than EMC filter’s max. Voltage, AC/DC module’s max. Input current must less than EMC filter’s max current.

Citation preview

Page 1: EMC Filter  FC-L01DV1 Series

EMC Filter FC-L01DV1 Series

EMC Filter

RoHS

FEATURES Compact size

Design to suppress the AC power surge

to achieve primary protection

Ensure the power supply module to meet the

requirement of CISPR22/ EN55022 Class B

Cost-effective

Low Temperature rise

This EMC filter applies to analog circuit which is noise-sensitive. Put FC-L01DV1 on to the input of AC/DC module can ensure the

module meet Surge level of IEC/EN61000-4-5 ±1KV (2Ω internal resistance)/±2KV (12Ω internal resistance)and EMI requirement of

CISPR22 /EN 55022 Class B. EM C filter used with the MORNSUN AC/DC module, AC/DC module’s max. Input voltage must not more than EMC filter’s max.

Voltage, AC/DC module’s max. Input current must less than EM C filter ’s max current.

Selection Guide

Model Input Voltage Range (VAC) Current (A)(max)

FC-L01DV1 85~305 0.3

General Specifications Item Test Conditions Min. Typ. Max. Unit

Operating Temperature -40 -- 85

Storage Temperature -40 -- 105 °C

Casing Temperature Rise 220VAC @0.3A -- -- 30

Leakage current (line to ground) 2000VAC,tested for 1 minute -- 2 -- mA

General Specifications Casing Material Black flame-retardant heat-proof epoxy resin (UL94-V0)

Package Dimensions 33.70X22.20X18.00 mm

Weight 20g (Typ)

Devise Standard

Put FC-L01DV1 on to the input of AC/DC module can ensure the module meet Surge level of IEC/EN61000-4-5 ±1KV (2Ω internal

resistance)/±2KV (12Ω internal resistance)and EMI requirement of CISPR22 /EN 55022 Class B.

Design Reference

1. Inside schematic

1 LM 1

4 LM 2

IN(L) OUT(L)

2 CY1

MOV1

CX

1

CY2

IN(N) 2 3

OUT(N)

2014.09.10-A/2 Page 1 of 3 MORNSUN

Guangzhou Science & Technology Co., Ltd. reserves the copyright and right of final interpretation

Page 2: EMC Filter  FC-L01DV1 Series

EMC Filter FC-L01DV1 Series

2. Typical application

L

FUS E L

L

FUS E

L

IN(L) O UT( L)

+

+

IN(L) OUT(L) LS0 3-0 5BXXK

LS 01

C1

LS0 3-0 5BXXKC

+ 5 Vo O UTPU T

10

Vo

FC-L01DV1 LS 03 -R2

FC -L01D V1 OUTPUT

C1

+ LS0 3-0 5BXXSC

N

7 LS 05

N

LS0 3-05BBY7S

IN(N)

IN(N)

LS 03

-

-

O UT(N)

N

OUT(N)

N

CY0

CY

FUSE: Due to the difference of the power module input current, the fuse of the recommended values, please refer to the Technical

Manual for the power module. C1, CY0, CY, LDM: parameter selection please refer to power supply technical manual.

3. Supporting the product model

Model EMI(Without EMI(With FC- Surge (Without Surge (With FC- EFT (Without EFT (With FC-

External Circuit ) L01DV1) Externa l Circuit) L01DV1) Externa l Circuit) L01DV1)

LS01

CISPR22/EN55022 IEC/EN61000-4-5 IEC/EN61000 -4 -4

-- -- ±1KV/±2K V -- ±4KV Series CLASS B perf. Criteria B perf. Criteria B

LS03

--

CISPR22/EN55022

--

IEC/EN61000-4-5

--

IEC/EN61000 -4 -4

±1KV/±2K V ±4KV Series CLASS B

perf. Criteria B perf. Criteria B

LS03-R2

CISPR22/EN55022 IEC/EN61000-4-5 IEC/EN61000 -4 -4

-- -- ±1KV/±2K V -- ±4KV Series CLASS B perf. Criteria B perf. Criteria B

LS05

CISPR22/EN55022 IEC/EN61000-4-5 IEC/EN61000-4 -4

-- -- ±1KV/±2K V -- ±4KV Series CLASS B perf. Criteria B perf. Criteria B

CISPR22/EN55022

IEC/EN61000-4-5 IEC/EN61000 -4 -4

LS03-05BXXK -- -- ±1KV/±2K V -- ±4KV CLASS B perf. Criteria B perf. Criteria B

4. For more information Please find the application notes on www.mornsun-power.com

2014.09.10-A/2 Page 2 of 3 MORNSUN

Guangzhou Science & Technology Co.,

Ltd. reserves the copyright and right of final interpretation

Page 3: EMC Filter  FC-L01DV1 Series

EMC Filter FC-L01DV1 Series

FC-L01DV1 Dimensions and Recommended Layout

Note: 1. Packing Information please refer to 'Product Packing Information'. Packing bag number: 58220014;

2. Unless otherwise specified, data in this datasheet should be tested under the conditions of Ta=25°C, humidity<75%;

3. All index testing methods in this datasheet are based on our Company’s corporate standards;

4. The performance indexes of the product models listed in this manual are as above, but some indexes of non -standard model

products will exceed the above-mentioned requirements, and please directly contact our technicians for specific information; 5. We can provide product customization service;

6. Specifications of this product are subject to changes without prior notice.

MORNSUN Guangzhou Science & Technology Co., Ltd. Address: No. 5, Kehui St. 1, Kehui Development Center, Science Ave., Guangzhou Science City, Luogang District, Guangzhou, P. R.

China Tel: 86-20-38601850-8801 Fax: 86-20-38601272 E-mail: [email protected]

2014.09.10-A/2 Page 3 of 3 MORNSUN

Guangzhou Science & Technology Co., Ltd. reserves the copyright and r ight of final interpretation