Finallya flowmeter that rises aboveall the rest and keeps youout of the sewer!
The Revolutionary NewFlowmeter TechnologyThe Revolutionary NewFlowmeter Technology
Now Offering A Full Range of
Flow Monitoring Solutions Flowmeter Sales Flowmeter Rentals Data Delivery Services
Now Offering A Full Range of
Flow Monitoring Solutions Flowmeter Sales Flowmeter Rentals Data Delivery Services
Finallya flowmeter that rises aboveall the rest and keeps youout of the sewer!
7/21/2019 flo-dar.pdf
2/4
Accurate FlowMeasurement for:Billing Purposes
EPA Permitting Requirements
Inflow/Infiltration Studies
Combined Sewer OverflowMonitoring
Process Control
Sampler Pacing
Modeling/Sewer SystemEvaluations
Wastewater Treatment PlantBalancing
Industrial Applications
Process Waste
Plant Influent
Plant EffluentRaw Sewage
Municipal Applications
Storm Water
Collection Systems
Raw Sewage
Combined Sewer Overflows
Waste Water Treatment PlantBalancing
Plant Influent
Plant Effluent
Permanent Sensor Wall Mount (Temporary
Mount Also Available)Bale with
Locking Slides
Ultrasonic
Level
Sensor
Radar Based
Velocity Sens
TThe Flo-Dar Flowmeter provides a revolutionary approach to openchannel flow monitoring. Flo-Dar combines advanced Digital Doppler
Radar velocity sensing technology with ultrasonic pulse echo level
sensing to remotely measure open channel flow.
Here's How It Works
Flo-Dar transmits a radar beam that interacts with the fluid and reflects
back signals at a different frequency than that which was transmitted. These
reflected signals are compared with the transmitted frequency. The resulting
frequency shift provides an accurate measure of the velocity and the
direction of the flow. Level is detected by ultrasonic pulse echo. Flow is
then calculated based on the Continuity Equation Q = V x A, Where Q = Flow,
V = Average Velocity and A = Area.
Accurate Flow Measurement
Flo-Dar provides the user with highly accurate flow measurements under a
wide range of flows and site conditions.
By measuring the velocity of the fluid from above, Flo-Dar eliminates
accuracy problems inherent with submerged sensors including sensor
disturbances, high solids content and distribution of reflectors.
Manage Your FlowmetersFrom Anywhere!
Ask us about Wired,Wireless and World WideWeb Solutions
Manage Your FlowmetersFrom Anywhere!
Ask us about Wired,Wireless and World WideWeb Solutions
7/21/2019 flo-dar.pdf
3/4
Perfect Solutionfor Difficult FlowConditions:
Flows with High Solids Co
High Temperature FlowsCaustic Flows
Large Man-Made Channel
High Velocities 20 ft/s
Shallow Flows
Benefits
Personnel have no
contact with flow duringinstallation
Maintenance causedby sensor fouling iseliminated
Field Replaceable/Interchangeable Sensors aMonitors
Portable Flo-Dar System utilizing Temporary Sensor Mount
Temporary sensor mount can be used for both permanent and portable applications.
Manage Your FlowmetFrom Anywhere!
Ask us about Wired,Wireless and World WWeb Solutions
Manage Your FlowmetFrom Anywhere!
Ask us about Wired,Wireless and World WWeb Solutions
when your data is already here?Imagine a reliable sewer flow monitoring networkthat doesnt require manhole visits.Imagine accurate data that is immediately andeffortlessly transmitted directly to your PC, PDA orsecure website.
Marsh-McBirney is already making this a reality forprofessionals just like you. Contact us today andwell show you how.
What are youdoinginhere...
7/21/2019 flo-dar.pdf
4/4
SENSOR
EnclosureMaterial: PolystyreneDimensions:
6.9 W x 16.65 L x 11.7 D(17.5 cm x 42.3 cm x 29.7 cm)
Weight: 10.5 lbs (4.8kg)Temperature
Operating Range: 14 F to 122 F(-10C to 50 C)
Storage Range: -40 F to 140 F (-40 C to 60 C)Sensor CableMaterial: Polyurethane jacketedStandard Length: 30 (9.14m), maximum 1000 (304.8 m).Disconnectable at both sensor and monitor
VELOCITY MEASUREMENTMethod: RadarRange: 0.75 to 20 ft/s (0.23 m/s to 6.10 m/s)Accuracy: 0.5%; 0.1 ft/s (0.03 m/s)
Specifications Flo-Dar Open Channel Flowmeter
ELECTRONICS
Portable DC Powered - Flo-Logger
Data Storage64K (16K cycles of
velocity/level data)Local Terminal
RS232C at 19.2K baud
Power RequirementsTwo 6-volt lantern batteries
HousingSealed watertight Polystyrene -meets IP68 ratingLength: 13.85 (35.179 cm)Diameter: 7 (17.78 cm)Weight: 7.5 lbs. (3.4 kg) (including batteries)
TemperatureOperating Range: 14 F to 125 F (-10 C to 51 C)Storage Range: -4 F to 125 F (-20 C to 51 C)
Sensor/Logger Disconnect
Both the sensor and the logger have waterproof(IP68) connectors for easy separation from theinterconnecting cable.
Set-up/Data Retrieval (All electronics)Flo-Ware for Windows software is the user on-siteset-up, data management, and report generationsoftware. It is compatible with desktop/portablecomputers utilizing Windows 95/98/2000/Me/NT/XP.Flo-Ware for Windows software can retrieve datafrom both Flo-Tote and Flo-Dar Flowmeters. Flo-Ware FX for PocketPC has all of the samefunctionality as Flo-Ware for Windows with theexception of report generation.
LEVEL MEASUREMENTMethod: UltrasonicStandard Operating Range: 0.25 to 60 in. (0.635 to 152.4 cm)Optional Operating Range: 0 (0 cm) to 224 (5.7 m) (with 16 dead band)Temperature CompensatedAccuracy: .1 in. ( .25 cm)1% Accuracy
SURCHARGE CONDITIONS LEVEL/VELOCITYLevel
Method: Piezo-resistive pressure transducer
Maximum Range: 138 inches (3.5 meters)VelocityMethod: ElectromagneticRange: -5 to +20 ft/s (-1.5 to +6.1 m/s)
FLOW MEASUREMENTBased on Continuity Equation.Accuracy: 5.0% of reading typical where flow is in a channel withuniform flow conditions and is not surcharged.
All Models: See Sensor Mount Insert Sheet
Intrinsically Safe Models Available -
Contact Factory
Flo-Ware Software
Marsh-McBirney, Inc., the Marsh-McBirney logo, and all other trademarks represented in this document are trademarks of their respective owners.
4539 Metropolitan Ct. Frederick, MD 21704-9452 U.S.A.(800) 368-2723 (301) 874-5599 FAX (301) 874-2172www.marsh-mcbirney.comISO 9001:2000 Certified Mfg. Facility
Permanent AC/DC PoweredFlo-Station with Display or Flo-Station without Display
Data Storage64K (16K cycles of velocity/level data)
Local TerminalRS232C at 19.2K baud
Optional DisplayDimensions: 1 x 3 Four line text display,FLOW, LEVEL, VELOCITY, TOTALIZERor any combination of any four channelscontaining data. Screens may be
programmed to alternate values displayed
Timebase Accuracy1 second per day
OutputsFour 4-20 mA outputs: system-isolated,up to 600 ohm load. Each output isselectable between FLOW, LEVEL,VELOCITY OR SURCHARGE LEVEL.
Contact ClosureDry contact closure with adjustable durationselectable for flow-proportional or alarmbased on: FLOW, LEVEL, VELOCITY,SURCHARGE. LEVEL, TEMPERATURE,BATTERY VOLTAGE, EACH SAMPLE,BAD SAMPLE OR ANALOG INPUT.Rating: 1A @ 30 VDC (resistive) 0.5A @125 VAC (resistive)
Power RequirementsAC: 85-264 VAC, 47-63 Hz, 32 wattsDC: 12 VDC for Flo-Station without
Display or Flo-Station with Display(Backlight Off) 180 mA (2.1 watts)with (1) 4-20 mA utilized.
HousingMaterial: ABS Plastic, NEMA 4Dimensions: 10.2W x 9.3H x 4D
(25.9 cm W x 23.6 cm H x 10.2 cm D)Weight: 5 lbs.
TemperatureOperating Range: 14 F to 122 F
(-10 C to 50 C)Storage Temperature:(without display) -40 F to 140 F
(-40 C to 60 C)(with display) 4 F to 140 F
(-20 C to 60 C) w/ display