Upload
others
View
0
Download
0
Embed Size (px)
Citation preview
에너지변환시스템연구실(ECOS)Energy Conversion System Lab. Chung H. Jeon
Fundamentals of THERMODYNAMICS
8th Edition, Richard Sonntag
CHAPTER 1Prof. Chung-Hwan Jeon
Office : 기전관 2층 2015호E-mail :[email protected]
Tel : 510-3051, 010-9241-5909
에너지변환시스템연구실(ECOS)Energy Conversion System Lab. Chung H. Jeon
• Introduction to Thermodynamics• Thermodynamic System and Control Volume• Properties, Processes and Cycles• Units• Specific Volume and Density• Pressure• Energy and Temperature
2
Chapter 1
에너지변환시스템연구실(ECOS)Energy Conversion System Lab. Chung H. Jeon
Introduction to Thermodynamics
Theory about science of energy, its conversion processes and its effect on substances and devices.
Subjects: Thermal systems, devices, componentsExamples: Steam Power Plant, Air conditioner (A/C) unit, Heater, Boiler,
Steam generator, Refrigerator, Engine, Pump, Nozzle, …
Subjects: Behavior and Properties of pure substancesExamples: When is water (H2O) a solid (ice), liquid or vapor (gas)
When air is compressed how much smaller does it become?How much energy is needed to bring cold water to a boil?At what pressure will R-410A (a refrigerant) boil at 35 C (95 F)
Subjects: Behavior or characteristics of devices or systemsExamples: How big a pump do I need to empty a swimming pool in 1 hour?
How much air must I blow into a balloon for a given size?How much work is involved to inflate a flat tire or balloon?
3
에너지변환시스템연구실(ECOS)Energy Conversion System Lab. Chung H. Jeon
Thermodynamic System and Control Volume
Control Volumes(mass)
Closed control volume: Open control volume:Encloses a fixed amount of mass Mass can enter or leaveAlso called control mass
Notice volume may change (A+B)
Control surface
Control surface
Piston-cylinder system
A
B
4
에너지변환시스템연구실(ECOS)Energy Conversion System Lab. Chung H. Jeon
Thermodynamic System and Control Volume
Closed control volume: Open control volume:Encloses a fixed amount of mass Mass can enter or leave
CV: argon, volume can go up
Heating at constant volume
Hot air balloon being inflated
Filling of a tank
5
에너지변환시스템연구실(ECOS)Energy Conversion System Lab. Chung H. Jeon
Complete system: Power Plant
WaterLoop
HeatLoop
(Condenser)
6
Conversion of fuel energy into electricity and heat Main Devices : B(Boiler), T(Turbines), G(Generator)
에너지변환시스템연구실(ECOS)Energy Conversion System Lab. Chung H. Jeon
핵심 개발기술
500MW Boiler Retrofit 주요 기술개발 내용
1. 시스템통합 및 최적화 분야○ 출력증강의 Plant Cycle 최적화 및 타당성 평가○ Plant Cycle 개념설계 및 설계기준서, ITB 작성○ Retrofit 플랜트의 연계설비간 동특성 해석 기술○ 출력증강 모듈 구축 및 프로세스 정립
2. 보일러 열용량 증대 분야○ 보일러 열용량, 성능향상 모듈 구축 및 개념설계○ 전열면 배치 최적화 기술 개발
○ 유동 및 화로해석, 전열부 유량불균형 예측기술○ 저급탄 연소용 Adv. Burner System 개발
3. 증기터빈 출력증강 및 효율향상 분야
○ T/G 출력증강 및 효율향상 모듈 구축 및 개념설계○ 중압 최종단의 장익(Long Bucket) 설계 기술개발○ 증기조건 변화에 따른 고압(HP) 1단(Control
Stage) 설계 기술개발○ 고효율 저진동 밸브 구동시스템 기술개발
에너지변환시스템연구실(ECOS)Energy Conversion System Lab. Chung H. Jeon
주요 개발내용 – 시스템통합 및 최적화
출력증대를 위한최적화 Case Study
설비별 고장확률 예측최적 온도/압력 조건 선정최적유량 결정
최적 Cycle Layout 구성
성능개선Plant 모듈구축 및
실증계획수립
출력증강 Target 달성을 위한 Plant Cycle 최적화
Plant 최적 Cycle 구성 및 설계 검토
설비 용량 검토
(주기기 및 보조기기)출력증대 경제성 평가
Plant Cycle Layout 검토기기 Interface 검토
General Arrangement 작성설계 계산 및 기준서 작성
(주기기 및 BOP 설비)설계 도면 작성
출령증대 Plant 개념설계
에너지변환시스템연구실(ECOS)Energy Conversion System Lab. Chung H. Jeon
(a) 화로모델링 (b) 각 버너단별 온도분포
연소해석 사례
버너 개략도
사용 예정 저급탄 후보 선정 및 각 연소특성 조사
버너 각 분사구 투입 연료량 및 유량 계산
버너 각 분사구 배치 기준 및 Size 선정 기준 도출탄종별 버너 존 슬래깅 생성 거동 차이 조사
화로내 연료 및 공기 분사각(Yaw Angle) 기준 도출
1. 저급탄의 안정적 연소, 버너존에서의 슬래깅 발생 최소화를 위한 버너 개념설계2. 버너 공기 및 미분탄 분사구의 유로면적 재설계, 화염 점화 거동 및 초기 연소 영역
변화를 고려한 연소시험/해석 Burner Basic Design
버너 개략도
Advanced Burner 개발
주요 개발내용
에너지변환시스템연구실(ECOS)Energy Conversion System Lab. Chung H. Jeon
10
1000MW USC 기술 – 보일러 핵심 설계
보일러화로설계기술
보일러저NOx연소시스템
보일러구조설계기술
보일러소음/진동해석기술
보일러기본설계시스템구축
-10 10 30 50 70 90 110 0
100
200
300
400
500
A
A
A
A
A
B
B
B
BB
C
C
CC C
D
D
D
D D
E EE
E
E
F F F F F
GG
G
G
G
0
100
200
300
400
500
600
0
10
20
30
40
50
0
20
40
60
80
100
0 1
Time(min)A: Inlet Steam Temperature B: O C: Inlet Fluegas Temperature D: O E: Steam Flow F: F G: Pressure at the outlet of HP part
Cold Startup : Final SupTraning(Poryong 3&
C
AB
C
CD
%
EF
ata
G
보일러동특성해석기술
50 100 150 2000
250
500
10090
8070
6050
4540
3530
2010
0
Pa
Hz
vaneopening(%)
차세대 모델 개념/기본설계
Unstable 영역
Unstable 영역
Stable 영역
Stable 영역
시스템통합 및 최적화
에너지변환시스템연구실(ECOS)Energy Conversion System Lab. Chung H. Jeon
11
Flow and Heat Transfer Inside a Tube
Fig. 4.9 Schematic diagram of the evaporation processes in a vertical tube (Adrian et al. 1986)
The location of the boiling crisis and the level the wall temperature rises to depend on numerous factors, such as the heat flux density, the mass flow density, the tube design and the steam quality.
에너지변환시스템연구실(ECOS)Energy Conversion System Lab. Chung H. Jeon
Natural Circulation
Schematic diagram of a natural-circulation steam generator .(Stultz and Kitto 1992)
Natural-circulation steam generators typically consist of economisers and an evaporatorwith risers that form the heated furnace wall, a drum for the separation of water from steam and unheated down pipes and superheaters.
에너지변환시스템연구실(ECOS)Energy Conversion System Lab. Chung H. Jeon
3D Geometry & Meshing (1,500,000 cell)[1] Hanger super-heater
580.78 m2
[2] Platen super-heater
1556.53 m2
[3] Final re-heater
1093.48 m2
[1]
[2]
[3]
[4]
[5][6]
Inlet T(K) 1375
Outlet T(K) 1461
Absorption(KJ/m^2-s)
65.24
Inlet T(K) 1198
Outlet T(K) 1375
Absorption(KJ/m^2-s)
41.00
Inlet T(K) 1073
Outlet T(K) 1198
Absorption(KJ/m^2-s)
87.93
Inlet T(K) 622
Outlet T(K) 716
Absorption(KJ/m^2-s)
9.161
Inlet T(K) 716
Outlet T(K) 944
Absorption(KJ/m^2-s)
66.55
Inlet T(K) 944
Outlet T(K) 1073
Absorption(KJ/m^2-s)
30.67
[4] Final super-heater[6] Economizer [5] Primary re-heater
2296.92 m21603.04 m2
2663.04m2
Boiler CFD 개발 내용_ 화로 수열부 모델링 완성
에너지변환시스템연구실(ECOS)Energy Conversion System Lab. Chung H. Jeon
500MW T-Firing boiler
Aux air
Aux air
Weak coal(B, D, F burner)
Conc.coal(B, D, F burner)
Aux air
Oil
Aux air
Conc. Coal(A, C, E burner)
Weak coal (A, C, E burner)
Bottom airBu
rner
zone
Uni
t bur
ner
Build up
Primary Air
Secondary Air
CASE 500MWDesign550MWDesign
550MWSUEK
550MWMix
550MWLoa
H.V(kcal/kg) 6080 6080 5954 5300 5090
Coal(Ton/h) 193 208 212.4 238.61 248.46
Air flow(Nm^3/s) 375.6 404.8 403.7 453.3 472
Con : Weak = 7:3
Boiler CFD 개발 내용_ 입력조건들
Aux air
Aux air
D Weak coal
D Conc.coal
Aux air
Oil
Aux air
C Conc. Coal
C Weak coal
Bottom air
에너지변환시스템연구실(ECOS)Energy Conversion System Lab. Chung H. Jeon
Validation as design coal
Iteration process Final results
Temperature O2 fraction Particle trajectory
0.22%
UnburnedCarbon
Exit O2
2%
Boiler CFD 개발 내용_ 모델 검증
에너지변환시스템연구실(ECOS)Energy Conversion System Lab. Chung H. Jeon
Complete system: Refrigerator
16
Refrigerator pushes energy out of a cold space into a warmer space (room)
Refrigerant flows in a loop through 4 devices
Fundamentals of THERMODYNAMICS �8th Edition, Richard Sonntag��CHAPTER 1Chapter 1Introduction to ThermodynamicsThermodynamic System and Control VolumeThermodynamic System and Control VolumeComplete system: Power Plant슬라이드 번호 7슬라이드 번호 8슬라이드 번호 9슬라이드 번호 10슬라이드 번호 11슬라이드 번호 12슬라이드 번호 13슬라이드 번호 14슬라이드 번호 15Complete system: RefrigeratorProperties, Processes and CyclesProperties, Processes and Cycles, ContinuedProperties, Processes and Cycles, ContinuedUNITSUNITSUNITSSpecific Volume and DensitySpecific Volume and Density, English UnitsConcept QuestionsPressurePressurePressureManometer/BarometerManometerManometerManometer/BarometerStatic/dynamic pressurePressurePressurePressurePressureManometer/BarometerPressure and Manometer Concept QuestionsEnergy and TemperatureTemperatureThermocouples, thermistors