    1. DOOR FRAMING TOWER ASSEMBLY 2. LEAD EDGE VERTICAL WEATHERSEALS ARE A BULB TYPE SHEET 

    RUBBER EPDM (ETHYLENE, PROPYLENE, DIENE, TERPOLYMER) WITH  A RESILIENT URETHANE FOAM CORE

     

    3. EMT ELECTRICAL CONDUIT, WITH ELECTRICAL RACEWAY WIRE WITHIN 

    4. FORMED ELECTRICAL RECESS PAN ASSEMBLY 5. ELECTRICAL - LOCKABLE - DISCONNECT 6. PRE-WIRED ELECTICAL CONTROL PANEL ASSEMBLY -TESTED AT THE FACTORY 7. PUSHBUTTON STATION - OPEN AND CLOSE

     

    8. FLEXIBLE ELECTRICAL CONDUIT TO THE OPERATOR ASSEMBLY 

    9. GEAR REDUCER 10. ELECTRIC BRAKE 11. ELECTRIC MOTOR 12. QUICK DISCONNECT OPERATOR BASE ASSEMBLY

     

    13. MANUAL MECHANICAL DISCONNECT FOR USE IN "NO-POWER" SITUATIONS 14. TOW BAR FOR OPERATING DOORS WITH A TUG IN "NO POWER" SITUATIONS 15. SINGLE ROW ROLLER CHAIN 16. SPUR GEAR/SPROKET ASSEMBLY

     

    17. DRIVE WHEEL/DRIVE WHEEL HOUSING ASSEMBLY 

    18. LOCKABLE FLUSH LATCH 19. BOTTOM RAIL WIPE 20. OPERATOR ACCESS COVER WITH WEATHER TIGHT PERIMETER SEAL

    ELECTRICAL OPERATOR ASSEMBLY

    6

    1

    4

    5

    7

    8

    10

    11

    13

    2018

    9

    19

    LEADING EDGE 

    CLOSING DIRECTION

    EXTERIOR

    16

    1214

    15

    17

    CHAIN ADJUSTMENT BOLT

    2

    Our pre-wired controls and all wiring internal to the powered door section iscompleted and tested at the factory minimizing field wiring requirements.  

    The quick disconnect operator assembly is a feature unique to Door Engineeand Manufacturing, LLC.

     

    - The single lever disengage mechanism completely separates the motorassembly from the drive wheel for a non-electrical powered operation. Thissystem eliminates the possibility of any damage to the gear reducer and elecmotor due to the reversal effort through the gear reducer and electric motor. also does not require release of the electric motor brake.

    - Horse Power 1/4 hp - 2 hp 

    - Electrical "Primary" standard 

    -480 volt, 3 phase, 60 Hz 

    • Option electrical  - 575 volt, 3 phase, 60 Hz  - 208 volt, 3 phase, 60 Hz  

    - 110 volt, single phase, 60 Hz 

    - Electical "Secondary" standard - Control voltage, 24 volt DC

     

    • Option - 110 volt AC 

    - Fixed Speed 45 (fpm) standard 

    • Option Speeds 30 fpm and 60 fpm • Option "VFD"

    (Variable Frequency Drive)  

    - Traction - Designed to meet .2 coeffiecent friction

    OPERATOR SPECIFICATION

    INTERIOR ELEVATION AT THE OPERATOR ASSEMBLYX

    XX