Upload
hoangthuy
View
220
Download
2
Embed Size (px)
Citation preview
921413000_09_005Page 1 from 4
13,6-14,8V DC
6mA
Bayblend FR3010, clear polycarbonate (red)
USAGE
BATTERY TYPE
For external use
12V/1,3Ah Pb (sealed lead-acid)
IP 34
115 dB / 1m
-10 60 Coέως
Up to 95%
2 years
1700gr.
290x95x190mm
BS-413
EN 50130-4, EN 55022, EN 60950-1
Technical characteristics
RELATIVE HUMIDITY
CONSTRUCTION MATERIAL
WEIGHT
EXTERNAL DIAMENSIONS
GUARANTEE
OPERATION VOLTAGE
QUIESCENT CONSUMPTION
SOUND LEVEL
PRODUCED IN ACCORDANCE WITH
OPERATION TEMPERATURE RANGE
DEGREES OF COVER PROTECTION
Autonomous electronic siren with beacon for burglar alarm panels
Thank you for purchasing this product of Olympia tampered with.Electronics. A European manufacturer. If you require, the siren to also be activated if the
siren is dismounted from the wall. you must Description connect the T1, T2 (TAMPER) inputs.The BS-413 alarm siren is of robust design and In case of maintenance or if the siren is moved can be used with conventional burglar alarm from it’s mounting position, the SE (Service) panels such as the BS-468. It has a red beacon input of the siren must be connected to the (-) of that blinks when the siren is activated and a the panel and the panel must be set to OFF.piezo speaker that produces a sound level of 115dB at 1 meter. BatteryThe incorporated tamper mechanism protects If the battery has not been connected then the the siren from unauthorized access when the siren produces a single tone sound every 1 cables are cut, the cover is removed or when second.the siren is unmounted from the wall. Whereas if the battery does not operate
correctly, a 3 tone sound is emitted every 12 Mounting hours.It is mounted externally on a flat surface and at a height of about 2,5 meters. Also it should be Beaconplaced in an area that does not obstruct the There is a two position (ON, OFF) jumper on the sound. siren which is marked (LED FLASΗ). If a link is
placed on the (ON) position, the beacon blinks WARNING!!! every 4 seconds in the quiescent state. If no All 4 mounting screws must be used. jumper is placed then the beacon is OFF during
the quiescent state and blinks during the alarm.ConnectionThe connection between the siren and the BS- Start signal468 panel is shown on figure 1. There is also another 2 position jumper marked After finishing with the connections, connect the (TRIGGER) with the positions (-) and (+). battery cables, install the internal cover and the This jumper sets if the trigger in positive or front fascia of the siren by installing the screws negative. Α positive trigger means that the ST on the bottom side. Finally remove the cable (START) signal must be a positive voltage for connected to the SE (Service) of the siren from the siren to be activated.the (-) of the panel. The siren will sound once to indicate that it is ready to operate and receive a command from the panel. The siren now charges the battery and is ready to accept an ALARM signal from the panel or if the cables are cut. If we connect the Τ1, Τ2 (TAMPER) signals then it will be activated if it is
High Quality European based Manufacturers
Alarm Alarm durationThe siren sounds the alarm in 2 cases, when The siren is activated for as long as an alarm the ST (START) signal is activated or when it’s signal is issued but stops after 7 minutes. The power is interrupted. siren will be reactivated with a new alarm signal.
A total of 7 cables are needed for connecting the siren. 2 cables are needed for connecting the siren power supply. The third cable is used for the ST (START) signal. The fourth cable is the signal for the beacon FL (FLASH), which in not mandatory for the operation of the siren. The fifth cable is for the SE (SERVICE) signal that prevents the siren from sounding during the installation. It must be connected during the connection procedure and disconnected (from the panel side) after the installation has finished. The remaining 2 cables are used for connecting the T1, T2 (TAMPER) inputs of the siren to the Ζ8 zone TAMPER of the panel. This method permits the siren to sound if tampered with and will also activate the auto telephone dialer.
1. Mounting points (All four screws must be used) 2. Inner cover mounting points3. Piezo megaphone4. Connection terminals5. Battery compartment 12V/1,2Ah6. TAMPER protection mechanism7. Beacon 8. Cable entry hole
Figure 2. The main parts of the siren
11
1
1
2
6
2
7
3
4
5
8
Jumpers
921413000_09_005Page 2 from 4
Installation Instructions
Connections
Z1 Z2 Z3 Z4 Z5 Z6 Z7 Z8 12V12V A B P1 P2 P3 AS ES NO C NC ANT
5K
6
Siren BS-413
Figure 1. Connecting a BS-413 siren to the BS-468 panel
Remove thiscable after the installation
has finished
24_HC C
12V ALARM RELAYSIRENS
NOCNCTC
EXT AUTO
Remove thiscable after the installation
has finished
SirenBS-413
Figure 2. Connecting a BS-413 siren to the BS-418 panel
921413000_09_005Page 3 from 4
SE
T1
T2
+
+
-
++ ST SE T1 T2FL