20
www.huawei.com HUAWEI TECHNOLOGIES CO., LTD. Huawei Smart PV-Plant Solution References 2014/12

Huawei Smart PV Plant References.pdf

Embed Size (px)

Citation preview

Page 1: Huawei Smart PV Plant References.pdf

www.huawei.com HUAWEI TECHNOLOGIES CO., LTD.

Huawei Smart

PV-Plant Solution

References 2014/12

Page 2: Huawei Smart PV Plant References.pdf

Europe

800MW

Page 3: Huawei Smart PV Plant References.pdf

Germany Reden Greencells 8MW PV-Plant

Capacity 7.8MW

Location Germany Reden

Solar

Inverter SUN2000-20KTL

Time 2014 May

Net voltage 10kV

Customer

Value

High efficiency/ 3 path MPPT

achieve high electricity generation

48kg/unit,easy-install;

IP65,No fuse、No fan,reliable

and reduce working cost;

Smart string testing provide

elaborate management, fault time is

reduced by 80%

Page 4: Huawei Smart PV Plant References.pdf

Germany Arneburg KS Solar 5.3MW PV-Plant

Capacity 5.3MW

Location Germany Arneburg

Solar

inverter SUN2000-20KTL

Time 2014 April

Net voltage 10kV

Customer

value

3 Path MPPT can match user

requirement more intellectively and

raise the electricity generation;

48kg/unit,easy-install;

IP65,No fuse、No fan,reliable

and reduce working cost;

Page 5: Huawei Smart PV Plant References.pdf

Germany Simmersdorf 500kW Roof Capacity 500kW

Location Germany Simmersdorf

Solar

Inverter SUN2000-20KTL

Time 2014 January

Net volatge 400V

Customer

Value

3 Path MPPT can match user

requirement more intellectively and

raise the electricity generation

48kg/unit,easy-install;

IP65,No fuse、No fan,reliable

and reduce working cost;

Page 6: Huawei Smart PV Plant References.pdf

Capacity 250 kWp

Location Toulouse ,FRANCH

Solar

Inverter Huawei SUN2000-20KTL

Time 2014 August

Net volatge 400 V

Customer

Value

High electricity generation, more

than original electricity station;

Smart Huawei Inverter can satisfy

smart install room requirement;

Sustain one phase MPPT, save the

cost by remove external box as UTE

require.

Franch Solveo 250kW Roof PV-Plant

Page 7: Huawei Smart PV Plant References.pdf

Capacity 8.2MW

Location FRANCH

Solar inverter Huawei SUN2000-28KTL

Time 2014 November

Net voltage 20kV

Customer

value

3 path MPPT can adopt different

solar panel and other solar device;

48kg, which can satisfy FRANCH2

requirement, save install cost also.,

IP65, free-maintenance

FRANCH Amarenco 8.2MW PV-Plant

Page 8: Huawei Smart PV Plant References.pdf

HUAWEI TECHNOLOGIES CO., LTD. Page 8

Japan

200MW

Page 9: Huawei Smart PV Plant References.pdf

HUAWEI TECHNOLOGIES CO., LTD. Page 9

Capacity 98kW(2*49kW)

Location Gum,Japan

Solar

Inverter SUN2000-24.5KTL 4 units

Net voltage 210V

Customer

Value

Service for Tokyo Electric Power

Perfectly match low-voltage project

High electricity generation under 3 phase

MPPT

IP65、free-maintenance

Japan Gum PV-Plant

Page 10: Huawei Smart PV Plant References.pdf

HUAWEI TECHNOLOGIES CO., LTD. Page 10

Capacity 220kW

Location Hiroshima,Japan

Solar

Inverter SUN2000-28KTL 8 units

Net voltage 6.6kV

Customer

Value

Multipath MPPT, reduce the influence from shadow and

obstacle

IP65, low reference on natural environment, no extra heat

sink device.

No DC converge box

Easy-maintenance

Japan Hiroshima 220kW PV-Plant

Page 11: Huawei Smart PV Plant References.pdf

HUAWEI TECHNOLOGIES CO., LTD. Page 11

Capacity 500kW

Location Hiroshima,Japan

Solar

Inverter SUN8000-500KTL 1 unit

Net

voltage 6.6kV

Customer

Value

High efficiency

No air-condition

Remote monitor

Remote operation

Japan Hiroshima 500kW PV-Plant

Page 12: Huawei Smart PV Plant References.pdf

HUAWEI TECHNOLOGIES CO., LTD. Page 12

Capacity 0.98MW

Location Nagasaki,Japan

Solar Inverter SUN2000-24.5KTL 40 units

Net voltage 210V

Customer

Value

High efficiency

Perfectly match low-voltage project

Remote monitor and free-maintenance

IP65

Japan Nagasaki 0.98MW PV-Plant

Page 13: Huawei Smart PV Plant References.pdf

China

4,500MW

Page 14: Huawei Smart PV Plant References.pdf

HUAWEI TECHNOLOGIES CO., LTD. Page 14

Jiaxing Zhejiang CGN 10MW Roof PV-Plant

Capacity 8.93MW

Location Zhejiang Jiaxing

Solar

Inverter SUN2000-20KTL

Time 2014 April

Net voltage 10kV

Customer

Value

Multipath MPPT achieve electricity

generation>10%;

48kg/unit,easy-install in roof;

IP65,adapt complex environment

around heat-engine plant/chemical

plant.

Page 15: Huawei Smart PV Plant References.pdf

HUAWEI TECHNOLOGIES CO., LTD. Page 15

Shunde Media 8MW Roof PV-Plant

Capacity 7.8MW

Location Guangdong Shunde

Solar

Inverter SUN2000-28KTL

Time 2014 April

Net voltage 10kV

Customer

Value

Multipath MPPT achieve electricity

generation>10%;

48kg/unit,easy-install in roof;

IP65,free-maintenance

Page 16: Huawei Smart PV Plant References.pdf

Aikang 2.2MW Roof

Background

Requirement

Huawei solution

Aikang solar project adapt Huawei SUN2000-

10KTL/ SUN2000-12KTL/ SUN2000-20KTL string

inverter, solar station adopt self-supply mode, with

2.2MW capacity.

Raise electricity generation;

Reduce fault time;

Enhance Roof station safety.

Raise electricity generation in 5~8%;

Smart string testing achieve elaborate manage,

reduce 80% of fault time;

No DC converge box, avoid DC transfer and

electric arc.

Page 17: Huawei Smart PV Plant References.pdf

Shandong Linuo Zhoucheng 4MW

Background

Requirement

Huawei Solution

Shandong Linuo Zhoucheng solar project, adopt

Huawei SUN2000-20KTL string solar inverter, build

smart PV-Plant with “smart, efficiency, safe and

reliable”.

Raise electricity generation

Reduce building time of PV-Plant;

Save maintenance cost.

Compared with centre inverter solution, electricity

generation is raised>10%;

No need to build inverter house, reduce building

time;

Free-maintenance, save OPEX.

Page 18: Huawei Smart PV Plant References.pdf

Zhejiang Tongjing 300MW PV-Agriculture

Background

Requirement

Huawei Solution

Zhejiang Tongjing solar project, adopt Huawei

SUN2000-28KTL string solar inverter, with Huawei 4G

LTE provide internal communication, build the biggest

ground smart PV-Plant in Huadong area.

Raise electricity generation

Reduce building time of PV-Plant;

Reduce fault time of inverter

Raise electricity generation in 20%-30%

Raise electricity generation in 3%(compared

with other company)

Easy-install;

6 path smart string testing, reduce 80% fault time

of location.

Page 19: Huawei Smart PV Plant References.pdf

Germu 200MW PV-Plant

Background

Requirement

Huawei solution

Germu PV-Plant project adopt Huawei

SUN2000-28KTL/SUN2000-35KTL string solar

solution, build smart PV-Plant with “smart, efficiency,

safe and reliable”.

Raise electricity generation;

Reduce fault time;

Reduce feedback time of investment.

Electricity generation is raised>5%(compared

with other company);

6 path smart string testing, reduce 80% fault time

of location.

Reduce maintenance cost, raise electricity

generation, reduce feedback time of investment.

Page 20: Huawei Smart PV Plant References.pdf

Copyright© 2014 Huawei Technologies Co., Ltd. All Rights Reserved.

The information in this document may contain predictive statements including, without limitation, statements regarding the future financial and operating

results, future product portfolio, new technology, etc. There are a number of factors that could cause actual results and developments to differ materially

from those expressed or implied in the predictive statements. Therefore, such information is provided for reference purpose only and constitutes neither an

offer nor an acceptance. Huawei may change the information at any time without notice.

More

Yields

Always Available for Highest Yields

Easy

Maintenance

Continuous

Service