Upload
wisthon-griman
View
11
Download
1
Embed Size (px)
DESCRIPTION
modelo de informe de ultrasonido panama empresa celsia
Citation preview
TECHNICAL REPORT
Ultrasonic testing in the crack
located in the upper case of
turbine 1 Rev: 00 March 2015 Page 1 of 13
WDS INGENIERIA, S.A. Inspected by: Report by:
Eng. Cuicas Wisthon Eng. Cuicas Wisthon
Calle Ferrer Arias, Edif Dos Mares View, Apto 2D, Dos Mares, Ciudad de Panam +507 6662 4768 / +507 68604245 [email protected]
ULTRASONIC TESTING IN THE UPPER
CASE BELONGING TO THE TURBINE 1
March 2015
TECHNICAL REPORT
Ultrasonic testing in the crack
located in the upper case of
turbine 1 Rev: 00 March 2015 Page 2 of 13
WDS INGENIERIA, S.A. Inspected by: Report by:
Eng. Cuicas Wisthon Eng. Cuicas Wisthon
Calle Ferrer Arias, Edif Dos Mares View, Apto 2D, Dos Mares, Ciudad de Panam +507 6662 4768 / +507 68604245 [email protected]
Panama, March 2015
Gentlemen:
CELSIA
Attention. Eng. Dominguez Milagros.
REF: Ultrasonic testing to upper case belonging to the turbine
Cot C1503-023S
Respected Engineer
Attached Technical Report Ultrasonic inspection, by WDS Ingeniera, S.A.,
Testing conducted in upper case belonging to turbine of CELSIA.
This report contains observations and conclusions relating to the service.
Best regards
ENG. Daniel Rivero ASNT-TC-1A Level II PT, VT, MT.
Level I UT, ECT AWS Member No 675950
TECHNICAL REPORT
Ultrasonic testing in the crack
located in the upper case of
turbine 1 Rev: 00 March 2015 Page 3 of 13
WDS INGENIERIA, S.A. Inspected by: Report by:
Eng. Cuicas Wisthon Eng. Cuicas Wisthon
Calle Ferrer Arias, Edif Dos Mares View, Apto 2D, Dos Mares, Ciudad de Panam +507 6662 4768 / +507 68604245 [email protected]
REPORT CONTENTS
1. OBJECTIVE
2. INSPECTION DATE, PERSONNEL AND EQUIPMENTS
3. INPECTION RESULTS AND ANALYSIS
4. ANNEXES
TECHNICAL REPORT
Ultrasonic testing in the crack
located in the upper case of
turbine 1 Rev: 00 March 2015 Page 4 of 13
WDS INGENIERIA, S.A. Inspected by: Report by:
Eng. Cuicas Wisthon Eng. Cuicas Wisthon
Calle Ferrer Arias, Edif Dos Mares View, Apto 2D, Dos Mares, Ciudad de Panam +507 6662 4768 / +507 68604245 [email protected]
1. OBJECTIVE
Evaluate by ultrasonic testing (UT) in the crack located in the upper case
of turbine 1
2. DATE OF INSPECTION, PERSONNEL AND EQUIPMENT
Inspection of the unions was held on February 25th 2015 in Colon, Panama
The staff was involved for inspection:
- Eng Cuicas Wisthon, ASNT-TC-1A Level II: VT, PT, MT, and UT.
EQUIPMENT USED:
- Ultrasound Equipment Olympus EPOCH LTX.
- Calibration block IIW Type 1.
- Digital Camera.
- Coupling Gel.
- Tape Measure.
TECHNICAL REPORT
Ultrasonic testing in the crack
located in the upper case of
turbine 1 Rev: 00 March 2015 Page 5 of 13
WDS INGENIERIA, S.A. Inspected by: Report by:
Eng. Cuicas Wisthon Eng. Cuicas Wisthon
Calle Ferrer Arias, Edif Dos Mares View, Apto 2D, Dos Mares, Ciudad de Panam +507 6662 4768 / +507 68604245 [email protected]
3. INSPECTION RESULTS, ANALYSIS AND RECOMMENDATIONS
During the ultrasound inspection of the crack belonging to the upper
case of the turbine 1, for the detection of the crack on the points UP-12,
UP-13, UP-14, UP-15, UP-16, UP-17, UP-18, UP-19, UP-20, LEFT-1, LEFT-
2, LEFT-3, LEFT-4, DOWN-15, DOWN-16, DOWN-17, DOWN-18, DOWN-
19 and DOWN-20, the gain was needed to be increased in 25Db to
manage to see the crack, otherwise it could have not been detected
anything, which could means that the crack is extremely thin at these
points, but due to the high gain it is difficult to know for sure.
TECHNICAL REPORT
Ultrasonic testing in the crack
located in the upper case of
turbine 1 Rev: 00 March 2015 Page 6 of 13
WDS INGENIERIA, S.A. Inspected by: Report by:
Eng. Cuicas Wisthon Eng. Cuicas Wisthon
Calle Ferrer Arias, Edif Dos Mares View, Apto 2D, Dos Mares, Ciudad de Panam +507 6662 4768 / +507 68604245 [email protected]
REINSPECTION REPORT ULTRASONIC FLAW DETECTOR
EQUIPMENT USED
Brand: Olympus Serial: SD010312 Model: EPOCH LTC
Transducer: Sonatest Dimensions: 0.250 " Frecuency: 2.25 MHz
Pattern calibration : ASME SECC V, ART 4 Pattern Reference: N / A Others:
TECHNICAL PARAMETERS AND INSPECTION
Technique: Defectology Range: 150 mm Reference level: 50 dB
DAC calibration beam path: N / A Reference Reflector: Scanning Level (dB):
Incident angle: 45 Beam exit: Normal and Tilt Coupling: Methylcellulose
Delay Probe delay Velocity PCS DSS
0,0 s 6,0 s 3280 m/s and 5800 m/s N/A N/A
Defects determination %DAC Defect type
Result
Weld Stamping Sector Ubicac. Length Depth height 45 60 70 Acept Reject
UP 1 39.42
UP 2 39.51
UP 3 38.41
UP 4 37.32
UP 5 38.01
UP 6 35.85
UP 7 34.26
UP 8 33.54
UP 9 34.26
UP 10 35.20
UP 11 36.33
UP 12 33.94
UP 13 38.21
UP 14 41.40
UP 15 43.28
UP 16 45.02
UP 17 39.69
MADE BY REVIEWED BY APPROVED BY
COMPANY
SIGNATURE
NAME ENG. Wisthon Cuicas Eng. Wisthon Cuicas Eng. Wisthon Cuicas
DATE 01-30-2014 01-30-2014 01-30-2014
TECHNICAL REPORT
Ultrasonic testing in the crack
located in the upper case of
turbine 1 Rev: 00 March 2015 Page 7 of 13
WDS INGENIERIA, S.A. Inspected by: Report by:
Eng. Cuicas Wisthon Eng. Cuicas Wisthon
Calle Ferrer Arias, Edif Dos Mares View, Apto 2D, Dos Mares, Ciudad de Panam +507 6662 4768 / +507 68604245 [email protected]
REINSPECTION REPORT ULTRASONIC FLAW DETECTOR
EQUIPMENT USED
Brand: Olympus Serial: SD010312 Model: EPOCH LTC
Transducer: Sonatest Dimensions: 0.250 " Frecuency: 2.25 MHz
Pattern calibration : ASME SECC V, ART 4 Pattern Reference: N / A Others:
TECHNICAL PARAMETERS AND INSPECTION
Technique: Defectology Range: 150 mm Reference level: 50 dB
DAC calibration beam path: N / A Reference Reflector: Scanning Level (dB):
Incident angle: 45 Beam exit: Normal and Tilt Coupling: Methylcellulose
Delay Probe delay Velocity PCS DSS
0,0 s 6,0 s 3280 m/s and 5800 m/s N/A N/A
Defects determination %DAC Defect type
Result
Weld Stamping Sector Ubicac. Length Depth height 45 60 70 Acept Reject
UP 18 36.00
UP 19 38.42
UP 20 ---------
DOWN 1 51.15
DOWN 2 49.22
DOWN 3 35.33
DOWN 4 36.21
DOWN 5 37.54
DOWN 6 35.60
DOWN 7 36.69
DOWN 8 38.22
DOWN 9 44.30
DOWN 10 45.68
DOWN 11 41.27
DOWN 12 39.05
DOWN 13 38.40
DOWN 14 41.23
DOWN 15 37.30
MADE BY REVIEWED BY APPROVED BY
COMPANY
SIGNATURE
NAME ENG. Wisthon Cuicas Eng. Wisthon Cuicas Eng. Wisthon Cuicas
TECHNICAL REPORT
Ultrasonic testing in the crack
located in the upper case of
turbine 1 Rev: 00 March 2015 Page 8 of 13
WDS INGENIERIA, S.A. Inspected by: Report by:
Eng. Cuicas Wisthon Eng. Cuicas Wisthon
Calle Ferrer Arias, Edif Dos Mares View, Apto 2D, Dos Mares, Ciudad de Panam +507 6662 4768 / +507 68604245 [email protected]
DATE 01-30-2014 01-30-2014 01-30-2014
REINSPECTION REPORT ULTRASONIC FLAW DETECTOR
EQUIPMENT USED
Brand: Olympus Serial: SD010312 Model: EPOCH LTC
Transducer: Sonatest Dimensions: 0.250 " Frecuency: 2.25 MHz
Pattern calibration : ASME SECC V, ART 4 Pattern Reference: N / A Others:
TECHNICAL PARAMETERS AND INSPECTION
Technique: Defectology Range: 150 mm Reference level: 50 dB
DAC calibration beam path: N / A Reference Reflector: Scanning Level (dB):
Incident angle: 45 Beam exit: Normal and Tilt Coupling: Methylcellulose
Delay Probe delay Velocity PCS DSS
0,0 s 6,0 s 3280 m/s and 5800 m/s N/A N/A
Defects determination %DAC Defect type
Result
Weld Stamping Sector Ubicac. Length Depth height 45 60 70 Acept Reject
DOWN 16 34.52
DOWN 17 43.38
DOWN 18 40.96
DOWN 19 42.31
DOWN 20 46.27
RIGHT 1 45.37
RIGHT 2 44.50
RIGHT 3 42.29
RIGHT 4 43.37
LEFT 1 39.80
LEFT 2 41.22
LEFT 3 40.36
LEFT 4 39.38
MADE BY REVIEWED BY APPROVED BY
COMPANY
SIGNATURE
TECHNICAL REPORT
Ultrasonic testing in the crack
located in the upper case of
turbine 1 Rev: 00 March 2015 Page 9 of 13
WDS INGENIERIA, S.A. Inspected by: Report by:
Eng. Cuicas Wisthon Eng. Cuicas Wisthon
Calle Ferrer Arias, Edif Dos Mares View, Apto 2D, Dos Mares, Ciudad de Panam +507 6662 4768 / +507 68604245 [email protected]
4. ANNEXES
NAME ENG. Wisthon Cuicas Eng. Wisthon Cuicas Eng. Wisthon Cuicas
DATE 01-30-2014 01-30-2014 01-30-2014
TECHNICAL REPORT
Ultrasonic testing in the crack
located in the upper case of
turbine 1 Rev: 00 March 2015 Page 10 of 13
WDS INGENIERIA, S.A. Inspected by: Report by:
Eng. Cuicas Wisthon Eng. Cuicas Wisthon
Calle Ferrer Arias, Edif Dos Mares View, Apto 2D, Dos Mares, Ciudad de Panam +507 6662 4768 / +507 68604245 [email protected]
TECHNICAL REPORT
Ultrasonic testing in the crack
located in the upper case of
turbine 1 Rev: 00 March 2015 Page 11 of 13
WDS INGENIERIA, S.A. Inspected by: Report by:
Eng. Cuicas Wisthon Eng. Cuicas Wisthon
Calle Ferrer Arias, Edif Dos Mares View, Apto 2D, Dos Mares, Ciudad de Panam +507 6662 4768 / +507 68604245 [email protected]
PHOTOGRAPHIC RECORD
TECHNICAL REPORT
Ultrasonic testing in the crack
located in the upper case of
turbine 1 Rev: 00 March 2015 Page 12 of 13
WDS INGENIERIA, S.A. Inspected by: Report by:
Eng. Cuicas Wisthon Eng. Cuicas Wisthon
Calle Ferrer Arias, Edif Dos Mares View, Apto 2D, Dos Mares, Ciudad de Panam +507 6662 4768 / +507 68604245 [email protected]
TECHNICAL REPORT
Ultrasonic testing in the crack
located in the upper case of
turbine 1 Rev: 00 March 2015 Page 13 of 13
WDS INGENIERIA, S.A. Inspected by: Report by:
Eng. Cuicas Wisthon Eng. Cuicas Wisthon
Calle Ferrer Arias, Edif Dos Mares View, Apto 2D, Dos Mares, Ciudad de Panam +507 6662 4768 / +507 68604245 [email protected]