36
EZKA/2017-09/00007-1 INITIAL TYPE TEST REPORT TIGCHEL FINOVEN 32 IN ORDER OF: VOF TIGCHELAAR TEGELKACHELS

INITIAL TYPE TEST REPORT - Peter Steen Ecologische ... · INITIAL TYPE TEST REPORT TIGCHEL FINOVEN 32 EZKA/2017-09/00007-1 NOVEMBER 15, 201 7 Laboratory Customer SGS NEDERLAND BV

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

Page 1: INITIAL TYPE TEST REPORT - Peter Steen Ecologische ... · INITIAL TYPE TEST REPORT TIGCHEL FINOVEN 32 EZKA/2017-09/00007-1 NOVEMBER 15, 201 7 Laboratory Customer SGS NEDERLAND BV

EZKA/2017-09/00007-1

INITIAL TYPE TEST REPORT

TIGCHEL FINOVEN 32

IN ORDER OF:

VOF TIGCHELAAR TEGELKACHELS

Page 2: INITIAL TYPE TEST REPORT - Peter Steen Ecologische ... · INITIAL TYPE TEST REPORT TIGCHEL FINOVEN 32 EZKA/2017-09/00007-1 NOVEMBER 15, 201 7 Laboratory Customer SGS NEDERLAND BV

SGS Nederland B.V. Malledijk 18 P.O. Box 200 3200 AE Spijkenisse The Netherlands t+31 (0)181 69 33 33 f+31 (0)181 62 35 66 www.sgs.com

R.C. Rotterdam No. 24226722 Member of the SGS Group

All orders are executed only in accordance with the latest version of our conditions filed at the Rotterdam District Court or the General Cargo Survey and

Inspection Conditions, last version, filed at the Rotterdam District Court and at the Chamber of Commerce in Rotterdam. Upon request the conditions will be sent to you.

INITIAL TYPE TEST REPORT

TIGCHEL FINOVEN 32

EZKA/2017-09/00007-1

NOVEMBER 15, 2017

Laboratory Customer

SGS NEDERLAND BV VOF Tigchelaar Tegelkachels

NOTIFIED BODY 0608

Tinweg 6

8445 PD Heerenveen

The Netherlands

Approved by ----------------------------------------------------------- Jens Dekker Project Leader

----------------------------------------------------------- Jaap Boot Operational Manager Air Monitoring

Page 3: INITIAL TYPE TEST REPORT - Peter Steen Ecologische ... · INITIAL TYPE TEST REPORT TIGCHEL FINOVEN 32 EZKA/2017-09/00007-1 NOVEMBER 15, 201 7 Laboratory Customer SGS NEDERLAND BV

Revision 1

Page 3 of 36

EZKA/2017-09/00007-1

SUMMARY

This report contains the test results of a room heater fired by solid fuels in accordance with EN

15250:2007.

Brief description of the project

An abstract of the results is presented below:

Abstract of the test results

Essential characteristic Performance

Test fuel Beech

Emission of combustion products, related to 13% O2

CO:

Dust:

0.10

37

vol%

mg/m03

Thermal output 169 MJ (43 kWh)

Thermal output per hour 2 kW

Energy efficiency 92.0%

Heat storage capacity

- Peak

- 50% of peak

- 25% of peak

4 hours

11 hours

15 hours

Surface temperature Pass

Fire safety Pass

Release of dangerous substances

Pass

Room heater Tigchel Finoven 32 is an intermittent burning appliance. The appliance is not suitable for

installation on a shared flue gas system.

This test report consists of pages 1 until 16 and the annexes 1, 2 and 3.

Description

Date of test September 14, 2017 September 15, 2017 September 19, 2017

Manufacturer VOF Tigchelaar Tegelkachels Tinweg 6 8445 PD Heerenveen the Netherlands

Principal VOF Tigchelaar Tegelkachels

Appliance Tigchel Finoven 32

Test category Initial type test

Page 4: INITIAL TYPE TEST REPORT - Peter Steen Ecologische ... · INITIAL TYPE TEST REPORT TIGCHEL FINOVEN 32 EZKA/2017-09/00007-1 NOVEMBER 15, 201 7 Laboratory Customer SGS NEDERLAND BV

Revision 1

Page 4 of 36

EZKA/2017-09/00007-1

TABLE OF CONTENTS

1. VERSION HISTORY ........................................................................................... 5

2. INTRODUCTION ................................................................................................. 6

3. PROJECT DETAILS ........................................................................................... 7

3.1 SPECIFICATION OF THE APPLIANCE ...................................................................... 7

3.2 SPECIFICATION OF THE LABORATORY .................................................................. 7

4. RESULTS OF ASSESMENTS ............................................................................ 8

4.1 USED MATERIALS, DESIGN AND CONSTRUCTION .................................................. 8

4.2 SAFETY REQUIREMENTS ................................................................................... 10

4.3 APPLIANCE INSTRUCTIONS ................................................................................ 11

4.4 MARKING ......................................................................................................... 11

5. MEASUREMENTS ............................................................................................ 12

5.1 MEASUREMENT METHODS................................................................................. 12

5.2 DEVIATION OF THE STANDARD ........................................................................... 12

5.3 TEST FUEL SPECIFICATION ................................................................................ 13

5.4 PERFORMANCE TEST AT NOMINAL HEAT OUTPUT ................................................ 14

5.5 TEMPERATURE SAFETY TEST ............................................................................ 16

APPENDICES ............................................................................................................. 17

LIST OF APPENDICES

Appendix 1: Picture of the appliance

Appendix 2: Drawings of the appliance

Appendix 3: Methods and measurements uncertainties

Page 5: INITIAL TYPE TEST REPORT - Peter Steen Ecologische ... · INITIAL TYPE TEST REPORT TIGCHEL FINOVEN 32 EZKA/2017-09/00007-1 NOVEMBER 15, 201 7 Laboratory Customer SGS NEDERLAND BV

Revision 1

Page 5 of 36

EZKA/2017-09/00007-1

1. Version history

Version Date Changes

0 November 6, 2017 Issued as final version

1 November 15, 2017 Name of company and appliance.

2

3 Whenever a new version is made, the prior version is cancelled.

Project Description

General information

Company name VOF Tigchelaar Tegelkachels

Address Tinweg 6, 8445 PD Heerenveen, the Netherlands

Internet address www.tigchelkachels.nl

Client reference number -

SGS reference number EZKA/2017-09/00007-1

Appliance

Appliance name Tigchel Finoven 32

Category Space heating appliance fired by solid fuel.

Method In accordance with EN 15250:2007

Measurement details

Kind of measurement Initial type test

Measurement period September 2017

Measuring staff R. van den Berg

Author Jens Dekker

Quality For a list of the accredited activities (RvA L092) of the SGS Nederland BV Environmental Services Department in Arnhem, The Netherlands, we refer to the last three pages of the Dutch Accreditation Council RvA website https://www.rva.nl/system/scopes/file_ens/000/000/076/original/L092-sce.pdf?1501168142 .

Disclaimers Unless agreed otherwise, all assignments are performed on the basis of the most recent version of the SGS Nederland BV General Terms and Conditions of Delivery. A simple request is all that is needed to have these terms and conditions sent to you again. We draw your attention to the limited liability, compensation and authorisation issues stipulated in these terms and conditions. Every holder of this document should be aware of the fact that the information contained therein only represents the findings of SGS Nederland BV at the moment of our intervention and within the boundaries of any instructions given by the commissioning party. SGS Nederland BV is liable to the commissioning party only, and this document does not exempt any parties involved in a business transaction of their duty to fulfil all the rights and obligations issuing from the transaction documents. Any permitted change to this document as well as imitations or forgeries of its contents or appearance are unlawful and violators will be prosecuted.

Page 6: INITIAL TYPE TEST REPORT - Peter Steen Ecologische ... · INITIAL TYPE TEST REPORT TIGCHEL FINOVEN 32 EZKA/2017-09/00007-1 NOVEMBER 15, 201 7 Laboratory Customer SGS NEDERLAND BV

Revision 1

Page 6 of 36

EZKA/2017-09/00007-1

2. INTRODUCTION

SGS Nederland BV, Environmental Services carried out an initial type test of room heater Tigchel

Finoven 32. The appliance is made by VOF Tigchelaar Tegelkachels.

This report contains the test results of a room heater fired by solid fuels in accordance with EN

15250:2007. Interpretations, opinions and assessments of conformity to clauses of this standard

(chapter 4) are done as Notified Body. Unless described otherwise the reported tests (chapter 5) are

covered by RvA-accreditation.

A short description of the appliance is included in chapter 3. Chapter 4 describes the results of the

assessments. The results of the measurements are presented in chapter 5.

This report is issued under the following condition:

1. It applies only to the tested model submitted to the test specified in this report.

2. It does not imply that the notified body has performed any surveillance or control of its manufacture.

3. The manufacturer shall ensure that the manufacturing process assures compliance of the products

with the approved model subject to this certificate.

4. The applicant shall inform the notified body of all modifications made to the approved model which

must receive, when necessary, additional approval leading to an addition to the original EC type-

examination certificate.

5. As technical advances or new work could affect the conclusion of this EC type-examination, the

applicant shall regularly keep himself informed of any modification made to tests carried out on the

approved model by the notified body.

6. According to article 3h of the “Assignment of SGS Nederland as Notified Body” you can lodge an

appeal against our decision. This appeal shall be made by registered mail within 30 days after the

date of the SGS decision. SGS undertakes to investigate the appeal independently and with the

necessary care and will communicate its motivated decision by registered mail within 30 days after

receipt of the notice of appeal. Each party itself shall bear its costs resulting from this internal

appeal procedure. In case this appeal is dismissed by SGS a second internal appeal procedure will

not be possible. 7. The manufacturer always retains the overall responsibility for the conformity of the product with all

the requirements of the applicable directive(s), even if some stages of the conformity assessment are carried out under the responsibility of a notified body.

Page 7: INITIAL TYPE TEST REPORT - Peter Steen Ecologische ... · INITIAL TYPE TEST REPORT TIGCHEL FINOVEN 32 EZKA/2017-09/00007-1 NOVEMBER 15, 201 7 Laboratory Customer SGS NEDERLAND BV

Revision 1

Page 7 of 36

EZKA/2017-09/00007-1

3. PROJECT DETAILS

In this chapter, the information of the appliance, the manufacturer and the laboratory are given.

3.1 SPECIFICATION OF THE APPLIANCE

Room heater Tigchel Finoven 32 is a freestanding slow heat release appliance made of ceramic

elements. The room heater is equipped with a front window door. The combustion chamber is made of

ceramic elements. The amount of combustion air can be regulated by moving:

- the ash pan cover (primary air);

- the secondary air controller at the right side of the appliance;

- the air controllers in the door (top and bottom).

Table 1 Information of the manufacturer

Description

Manufacturer VOF Tigchelaar Tegelkachels Tinweg 6 8445 PD Heerenveen the Netherlands

Principal VOF Tigchelaar Tegelkachels

Appliance Tigchel Finoven 32

3.2 SPECIFICATION OF THE LABORATORY

Table 2 Information of the test laboratory

Description

Laboratory Name, address

SGS Nederland BV Leemansweg 51 6827 BX Arnhem the Netherlands

Notified under EC number 0608

Date of test September 14, 2017 September 15, 2017 September 19, 2017

Test category Initial type test

Standard EN 15250:2007

The analysis of the fuel is subcontracted by an ISO 17025 accredited laboratory within the SGS-group.

Page 8: INITIAL TYPE TEST REPORT - Peter Steen Ecologische ... · INITIAL TYPE TEST REPORT TIGCHEL FINOVEN 32 EZKA/2017-09/00007-1 NOVEMBER 15, 201 7 Laboratory Customer SGS NEDERLAND BV

Revision 1

Page 8 of 36

EZKA/2017-09/00007-1

4. RESULTS OF ASSESMENTS

This chapter contains the results of the assessments.

4.1 USED MATERIALS, DESIGN AND CONSTRUCTION

Table 3 Results of assessment of conformity with chapter 4 of EN 15250:2007 Clause Approved

Production documentation (not reviewed)

Documentation and/or drawings contain: - Specification of used materials - Fuel loading mass - Number and mass of batch charges - Time duration to reach maximum mean surface temperature value, 50% and 25% of that maximum. - Total amount of heat energy stored in the appliance during the fuel burning period

- Nominal heat output using recommended fuels

4.1 -

Construction (4.2.1)

The conformity to clause 4.2.1 (with *) is based on the declaration of the manufacturer.

General construction requirements

*No asbestos *No hard solder, containing cadmium *Thermal insulation materials: non-combustible, no health risk * Design of spare parts ensures correct fitting

When operated in accordance with the provisions of the appropriate test and exposed to the associated mechanical, chemical and thermal stresses, the appliance shall operate reliably and safely such that during normal operation no combustion gases posing a hazard can escape into the room in which the appliance is installed nor can embers fall out.

4.2.1

ok ok ok ok

ok

Cleaning of heating surfaces

- all heating surfaces accessible - easy cleaning with commercially available tools or brushes

4.2.2

ok ok

Flue spigot or socket

Secure and gastight connection Overlap length: Horizontal → > 40 mm Vertical → > 25 mm

4.2.3

ok n/a ok

Flue ways and cleaning tools

Minimum size: - bituminous coal > 30 mm - no bituminous coals > 15 mm - easy cleaning with commercially available tools or brushes - cleaning tools provided by the manufacturer

4.2.4

n/a ok ok n/a

Ash pan and ash removal

Volume of ash pan enough for two full charges of fuel No obstruction of combustion air

4.2.5

ok ok

Bottom grate 4.2.6

Page 9: INITIAL TYPE TEST REPORT - Peter Steen Ecologische ... · INITIAL TYPE TEST REPORT TIGCHEL FINOVEN 32 EZKA/2017-09/00007-1 NOVEMBER 15, 201 7 Laboratory Customer SGS NEDERLAND BV

Revision 1

Page 9 of 36

EZKA/2017-09/00007-1

Clause Approved

When removable – correct assembly is ensured Capable of de-ashing without undue effort

ok ok

Combustion air supply

Primary air inlet control: - manual or thermostatic control - adjusting control clearly visible and permanently marked - correct setting for each fuel type is identifiable - no obstruction of the air inlet control by ash or unburned fuel - Cold setting clearly marked and described in the user instructions

Secondary air (air wash) inlet control: - Passage of air is not restricted by fuel

4.2.7

ok ok n/a ok ok

ok

Control of flue gas

If flue damper is fitted: - easily operable

- aperture ≥ 20 cm2 or 3% of the cross-sectional area - position of damper can be identified If draught regulator is fitted: - easily accessible for cleaning

4.2.8

ok ok ok

n/a

Fire doors and charging doors

Large enough to fill appliance with commercially available fuels Accidental opening is prevented Positive closure

4.2.9

ok ok ok

Flue bypass device*

Easy operable Position easily identifiable

* not present on tested proto-type.

4.2.10

n/a n/a

Front fire bars – deepening plate

When removable – correct assembly is ensured No accidental dislodging

4.2.11

n/a ok

Page 10: INITIAL TYPE TEST REPORT - Peter Steen Ecologische ... · INITIAL TYPE TEST REPORT TIGCHEL FINOVEN 32 EZKA/2017-09/00007-1 NOVEMBER 15, 201 7 Laboratory Customer SGS NEDERLAND BV

Revision 1

Page 10 of 36

EZKA/2017-09/00007-1

4.2 SAFETY REQUIREMENTS

Table 4 Results of assessment of conformity with chapter 5 of EN 15250:2007 Clause Approved

Temperature in fuel storage container (above ambient)

Temperature < 65 K

5.1 n/a

Operating tools

Operating tools provided Touched areas without tools Temperature: metal < 35 K (above ambient) porcelain < 45 K plastics, rubber, wood < 60 K

5.2

ok n/a

Temperature of adjacent combustible materials

Temperature ≤ 65 K (above ambient) (see installation and operating manual for information about clearing distances and insulation)

5.3

ok

Electrical safety

Components in compliance with EN 60335-2-102 (replacement of EN 560165)

5.4 n/a

clause 5.11 is based on the declaration of the manufacturer.

Page 11: INITIAL TYPE TEST REPORT - Peter Steen Ecologische ... · INITIAL TYPE TEST REPORT TIGCHEL FINOVEN 32 EZKA/2017-09/00007-1 NOVEMBER 15, 201 7 Laboratory Customer SGS NEDERLAND BV

Revision 1

Page 11 of 36

EZKA/2017-09/00007-1

4.3 APPLIANCE INSTRUCTIONS

Table 5 Results of assessment of conformity with chapter 7 of EN 15250:2007 Instructions Clause Approved

In the language of the country of intended destination

7.1 -

Not in contradiction to the requirements and test results

7.1 -

Contains the required information 7.2 -

Contains the required information 7.3 -

Not reviewed. The manufacturer must supply a manual that conforms to the EN15250 with every sold appliance.

4.4 MARKING

Table 6 Results of assessment of conformity with chapter 8 of EN 15250:2007

Clause Approved

Permanently and legibly marked Readable

8 8

- -

Durable and abrasion proof No discoloration or detachment

8 8

- -

Contains the required information 8 -

Not reviewed. The manufacturer must supply a CE-plate that conforms to the EN15250 with every sold appliance.

Page 12: INITIAL TYPE TEST REPORT - Peter Steen Ecologische ... · INITIAL TYPE TEST REPORT TIGCHEL FINOVEN 32 EZKA/2017-09/00007-1 NOVEMBER 15, 201 7 Laboratory Customer SGS NEDERLAND BV

Revision 1

Page 12 of 36

EZKA/2017-09/00007-1

5. MEASUREMENTS

In this chapter the measurement methods, the deviation from the standard and the test results are

given.

5.1 MEASUREMENT METHODS

The appliance was tested to the applicable methods of the standard.

In order to ensure that our services maintain the quality level required by our clients, SGS Nederland

BV hold the NEN-EN-ISO/IEC 17025 (Testlab) accreditation under number L092. The test laboratory of

SGS is notified under EC number 0608. The following test methods are covered.

Table 7 Used methods with accreditation

Description Method

Burning rate performance test EN 15250:2007/ A.4.6

Temperature safety test for wood burning and multi fuel appliances EN 15250:2007/ A.4.7

The analysis of the fuel is subcontracted by an ISO 17025 accredited laboratory within the SGS-group.

5.2 DEVIATION OF THE STANDARD

The nominal heat output tests and the safety test are done in compliance with EN 15250:2007. The

following deviations from the demands as set in the standard are made:

- The analysis of the test fuel was done according to widely accepted EN-Standards. In general the

used Standards improve the accuracy and reduce the variability of the analysis. This deviation from the

standard has no influence on the results of the type test.

Page 13: INITIAL TYPE TEST REPORT - Peter Steen Ecologische ... · INITIAL TYPE TEST REPORT TIGCHEL FINOVEN 32 EZKA/2017-09/00007-1 NOVEMBER 15, 201 7 Laboratory Customer SGS NEDERLAND BV

Revision 1

Page 13 of 36

EZKA/2017-09/00007-1

5.3 TEST FUEL SPECIFICATION

In this paragraph the results of the test fuel analysis are given.

Table 8 Test fuel specification

Test fuel Moisture

%

Ash

%

Volatile

matter %

H

%

C

%

S

%

Hu

kJ/kg

Size,

length

Beech 13.9 0.40 85.6 5.7 42.9 0.02 16,447 23 cm

Picture 1 Position of the wood during the nominal tests

Page 14: INITIAL TYPE TEST REPORT - Peter Steen Ecologische ... · INITIAL TYPE TEST REPORT TIGCHEL FINOVEN 32 EZKA/2017-09/00007-1 NOVEMBER 15, 201 7 Laboratory Customer SGS NEDERLAND BV

Revision 1

Page 14 of 36

EZKA/2017-09/00007-1

5.4 PERFORMANCE TEST AT NOMINAL HEAT OUTPUT

The following tables contain the test results in accordance with A.4.6 of EN 15250:2007. The fuel was

added in one batch.

Table 9 Test results nominal heat output (1/2)

Clause Test 1 Test 2

Mean of 2

tests Requirement Approved

Date (dd-mm-yy) 14-09-17 15-09-17

FUEL

Test fuel beech beech

Total mass kg 11.10 11.30 11.19

Period adding batch charges h A.4.6.2 One load

only One load

only One load

only < 3 h ok

Combustion time h 1.17 1.01 1.09

SETTINGS

- Ash pan Slightly open

- Secondary air 50%

- Door top 50%

- Door low 50%

Mean flue draught Pa 6.4 12.3 12.1 12.2 12 (±2) ok

EMISSIONS

Mean flue gas temperature oC 6.1 49 65 57

Mean CO2 concentration % 5.30 6.16 5.70

Mean CO concentration % 0.07 0.07 0.07

Mean CO concentration at 13% O2 vol% 6.3 0.11 0.09 0.10 ≤0.3 ok

Mean CO concentration at 13% O2 mg/m03 1325 1113 1226

CO concentration mg/MJ 860 722 796

Mean CO2 concentration during dust measurement

vol% 7.60 7.29 7.46

Dust concentration mg/m03 40 32 36

Dust concentration at 13% O2 mg/m03 40 33 37

Dust concentration mg/MJ 26 21 24

NOx concentration mg/m03 80 81 81

NOx concentration at 13% O2 mg/m03 113 100 107

NOx concentration mg/MJ 74 65 69

CxHy concentration mg/m03 22 25 23

CxHy concentration at 13% O2 mg/m03 31 30 31

CxHy concentration mg/MJ 22 21 21

HEAT OUTPUT

Thermal heat losses % 6.2 7.2 6.7

Chemical heat losses % 0.9 0.7 0.8

Heat losses due to combustible constituents in the residue

% 0.50 0.50 0.50

Efficiency % 6.3 92.4 91.6 92.0 ≥70 ok

Mean nominal heat to space MJ 6.6 169 170 169

Mean nominal heat to space kW 6.6 40.2 46.8 43.3

Mean nominal heat to space kW/hr 2 2 2

Flue gas mass flow g/s 53 55 54

Page 15: INITIAL TYPE TEST REPORT - Peter Steen Ecologische ... · INITIAL TYPE TEST REPORT TIGCHEL FINOVEN 32 EZKA/2017-09/00007-1 NOVEMBER 15, 201 7 Laboratory Customer SGS NEDERLAND BV

Revision 1

Page 15 of 36

EZKA/2017-09/00007-1

Table 10 Test results nominal heat output (2/2)

Thermal Storage Capacity

100% peak

50% of peak

25% of peak

h

6.6

4

10

14

4

12

16

4

11

15

-

≥4

-

ok

Page 16: INITIAL TYPE TEST REPORT - Peter Steen Ecologische ... · INITIAL TYPE TEST REPORT TIGCHEL FINOVEN 32 EZKA/2017-09/00007-1 NOVEMBER 15, 201 7 Laboratory Customer SGS NEDERLAND BV

Revision 1

Page 16 of 36

EZKA/2017-09/00007-1

5.5 TEMPERATURE SAFETY TEST

The following table contains the test results in accordance with A.4.7 of EN 15250:2007.

Table 10 Results safety test

* Appliance must be placed on a non-combustible floor.

§ Test Approved

Date (dd-mm-yy) 19-09-17

Test fuel Beech

Total load kg 22.4

Number of loads 2

Setting of air slide (batch 2)

- Ash pan Slightly open

- Secondary air 50%

- Door top 50%

- Door low 50%

Mean flue draught (batch 2) Pa 6.4 15 ok

Ambient temperature °C 20.2

Max. surface temperature

(above ambient)

n/a Floor * - 5.6 -

Floor in front of appliance (distance 20 cm)

K 5.6 64 ok

Back wall (non combustible)

K 5.6 - n/a

Sidewall (distance 10 cm)

K 5.6 59 ok

Front (distance 130 cm)

K 5.6 53 ok

Fuel storage container K 5.4 n/a n/a

Loss of fire bed 4.2 no ok

Escape of harmful combustion

gases

4.2 no ok

Damage on the appliance caused by the

test 4.2 none ok

Page 17: INITIAL TYPE TEST REPORT - Peter Steen Ecologische ... · INITIAL TYPE TEST REPORT TIGCHEL FINOVEN 32 EZKA/2017-09/00007-1 NOVEMBER 15, 201 7 Laboratory Customer SGS NEDERLAND BV

Revision 1

Page 17 of 36

EZKA/2017-09/00007-1

APPENDICES

APPENDIX 1: PICTURE OF THE APPLIANCE

Page 18: INITIAL TYPE TEST REPORT - Peter Steen Ecologische ... · INITIAL TYPE TEST REPORT TIGCHEL FINOVEN 32 EZKA/2017-09/00007-1 NOVEMBER 15, 201 7 Laboratory Customer SGS NEDERLAND BV

Revision 1

Page 18 of 36

EZKA/2017-09/00007-1

APPENDIX 2: DRAWINGS OF THE APPLIANCE

Page 19: INITIAL TYPE TEST REPORT - Peter Steen Ecologische ... · INITIAL TYPE TEST REPORT TIGCHEL FINOVEN 32 EZKA/2017-09/00007-1 NOVEMBER 15, 201 7 Laboratory Customer SGS NEDERLAND BV

Revision 1

Page 19 of 36

EZKA/2017-09/00007-1

Page 20: INITIAL TYPE TEST REPORT - Peter Steen Ecologische ... · INITIAL TYPE TEST REPORT TIGCHEL FINOVEN 32 EZKA/2017-09/00007-1 NOVEMBER 15, 201 7 Laboratory Customer SGS NEDERLAND BV

Revision 1

Page 20 of 36

EZKA/2017-09/00007-1

Page 21: INITIAL TYPE TEST REPORT - Peter Steen Ecologische ... · INITIAL TYPE TEST REPORT TIGCHEL FINOVEN 32 EZKA/2017-09/00007-1 NOVEMBER 15, 201 7 Laboratory Customer SGS NEDERLAND BV

Revision 1

Page 21 of 36

EZKA/2017-09/00007-1

Page 22: INITIAL TYPE TEST REPORT - Peter Steen Ecologische ... · INITIAL TYPE TEST REPORT TIGCHEL FINOVEN 32 EZKA/2017-09/00007-1 NOVEMBER 15, 201 7 Laboratory Customer SGS NEDERLAND BV

Revision 1

Page 22 of 36

EZKA/2017-09/00007-1

Page 23: INITIAL TYPE TEST REPORT - Peter Steen Ecologische ... · INITIAL TYPE TEST REPORT TIGCHEL FINOVEN 32 EZKA/2017-09/00007-1 NOVEMBER 15, 201 7 Laboratory Customer SGS NEDERLAND BV

Revision 1

Page 23 of 36

EZKA/2017-09/00007-1

Page 24: INITIAL TYPE TEST REPORT - Peter Steen Ecologische ... · INITIAL TYPE TEST REPORT TIGCHEL FINOVEN 32 EZKA/2017-09/00007-1 NOVEMBER 15, 201 7 Laboratory Customer SGS NEDERLAND BV

Revision 1

Page 24 of 36

EZKA/2017-09/00007-1

Page 25: INITIAL TYPE TEST REPORT - Peter Steen Ecologische ... · INITIAL TYPE TEST REPORT TIGCHEL FINOVEN 32 EZKA/2017-09/00007-1 NOVEMBER 15, 201 7 Laboratory Customer SGS NEDERLAND BV

Revision 1

Page 25 of 36

EZKA/2017-09/00007-1

Page 26: INITIAL TYPE TEST REPORT - Peter Steen Ecologische ... · INITIAL TYPE TEST REPORT TIGCHEL FINOVEN 32 EZKA/2017-09/00007-1 NOVEMBER 15, 201 7 Laboratory Customer SGS NEDERLAND BV

Revision 1

Page 26 of 36

EZKA/2017-09/00007-1

Page 27: INITIAL TYPE TEST REPORT - Peter Steen Ecologische ... · INITIAL TYPE TEST REPORT TIGCHEL FINOVEN 32 EZKA/2017-09/00007-1 NOVEMBER 15, 201 7 Laboratory Customer SGS NEDERLAND BV

Revision 1

Page 27 of 36

EZKA/2017-09/00007-1

Page 28: INITIAL TYPE TEST REPORT - Peter Steen Ecologische ... · INITIAL TYPE TEST REPORT TIGCHEL FINOVEN 32 EZKA/2017-09/00007-1 NOVEMBER 15, 201 7 Laboratory Customer SGS NEDERLAND BV

Revision 1

Page 28 of 36

EZKA/2017-09/00007-1

Page 29: INITIAL TYPE TEST REPORT - Peter Steen Ecologische ... · INITIAL TYPE TEST REPORT TIGCHEL FINOVEN 32 EZKA/2017-09/00007-1 NOVEMBER 15, 201 7 Laboratory Customer SGS NEDERLAND BV

Revision 1

Page 29 of 36

EZKA/2017-09/00007-1

Page 30: INITIAL TYPE TEST REPORT - Peter Steen Ecologische ... · INITIAL TYPE TEST REPORT TIGCHEL FINOVEN 32 EZKA/2017-09/00007-1 NOVEMBER 15, 201 7 Laboratory Customer SGS NEDERLAND BV

Revision 1

Page 30 of 36

EZKA/2017-09/00007-1

Page 31: INITIAL TYPE TEST REPORT - Peter Steen Ecologische ... · INITIAL TYPE TEST REPORT TIGCHEL FINOVEN 32 EZKA/2017-09/00007-1 NOVEMBER 15, 201 7 Laboratory Customer SGS NEDERLAND BV

Revision 1

Page 31 of 36

EZKA/2017-09/00007-1

Note: bypass not present on tested proto type.

Page 32: INITIAL TYPE TEST REPORT - Peter Steen Ecologische ... · INITIAL TYPE TEST REPORT TIGCHEL FINOVEN 32 EZKA/2017-09/00007-1 NOVEMBER 15, 201 7 Laboratory Customer SGS NEDERLAND BV

Revision 1

Page 32 of 36

EZKA/2017-09/00007-1

Page 33: INITIAL TYPE TEST REPORT - Peter Steen Ecologische ... · INITIAL TYPE TEST REPORT TIGCHEL FINOVEN 32 EZKA/2017-09/00007-1 NOVEMBER 15, 201 7 Laboratory Customer SGS NEDERLAND BV

Revision 1

Page 33 of 36

EZKA/2017-09/00007-1

Page 34: INITIAL TYPE TEST REPORT - Peter Steen Ecologische ... · INITIAL TYPE TEST REPORT TIGCHEL FINOVEN 32 EZKA/2017-09/00007-1 NOVEMBER 15, 201 7 Laboratory Customer SGS NEDERLAND BV

Revision 1

Page 34 of 36

EZKA/2017-09/00007-1

Page 35: INITIAL TYPE TEST REPORT - Peter Steen Ecologische ... · INITIAL TYPE TEST REPORT TIGCHEL FINOVEN 32 EZKA/2017-09/00007-1 NOVEMBER 15, 201 7 Laboratory Customer SGS NEDERLAND BV

Revision 1

Page 35 of 36

EZKA/2017-09/00007-1

Page 36: INITIAL TYPE TEST REPORT - Peter Steen Ecologische ... · INITIAL TYPE TEST REPORT TIGCHEL FINOVEN 32 EZKA/2017-09/00007-1 NOVEMBER 15, 201 7 Laboratory Customer SGS NEDERLAND BV

Revision 1

Page 36 of 36

EZKA/2017-09/00007-1

APPENDIX 3: METHODS AND MEASUREMENTS UNCERTAINTIES

All measurements mentioned in the table below, are covered by ISO 17025 certification.

Description SGS Procedure/Standard Uncertainties 1)

Determination of the particulate

concentration (gravimetric)

ENVI-K-004 30 %

Determination of the CxHy concentration

(equivalents of C3H8) (FID)

ENVI-K-004

20 %

Determination of the NOx concentration

(equivalents of NO2) (Chemiluminescent)

ENVI-K-004 9 %

Determination of the gas temperature

(thermocouple)

ENVI/L/03

conform ISO 8756 0.75% of the measured value or

± 1.5 °C (largest value)

Determination of the CO2 concentration

(nondispersive infrared)

ENVI-K-004

9 %

Determination of the CO concentration

(nondispersive infrared)

ENVI-K-004

9 %

1) The stated uncertainties refer to the 95% confidence interval (2 sigma). The stated percentages are related to the actual measurement results, unless indicated otherwise.