2
Feature Specification Appearrance Brass Double Stage Regulator for Industrial Gases For High pressure JET-Vc Flow Temperature Materials Weight Body Diaphragm Filter The others 15m 3 /h(nor) -540C3771 CR, Fluororesin Sintered SUS C3604, Fluororesin 1.3kghttp://nissantanaka.com Flow Rate 0.25 0.20 0.15 0.10 0.05 0.00 Qm 3 /h nor)(Nitrogen0 2 4 6 8 10 12 P1: 13MPa 0.6 0.5 0.4 0.3 0.2 0.1 0 Qm 3 /h nor)(Nitrogen0 5 10 15 20 25 30 P1: 8MPa Supply Pressure Effect 0.6 0.5 0.4 0.3 0.2 0.1 0 P1 MPa 0 9 10 11 12 13 14 15 1 2 3 4 5 6 7 8 Q: 10L/min Q: 5L/min Q: 0L/min Q: 50L/min 1. This Double Stage regulator eliminates the effect of supply pressure. 2. Connect several kinds of accessory like a flowmeter, needle valve, or prefered accesories. 3. Keeps gas purity because the diaphragm is used Teflon cover. 4. Supplies a micro flow rate. 5. Has a filter in the body. It eliminates the possibility of internal leakage. (90) (88) (43) W22-14RH M16×1.5R OUT IN 1/4"(Ø6.35) (90) (92) M16×1.5R OUT IN W22-14 RH (90) Outlet Connection F1(99),F3F6(109) M16×1.5R 1/4"(Ø6.35) M16×1.5R OUT IN W22-14R JET-Vc70 JET-Vc103 JET-Vc50

JET-Vc - NISSAN TANAKAnissantanaka.com/english/news/JET-Vc.pdf · JET - VcB - S - B5G ② G - ③ ④ - ⑤ 1 0 0 0 ※③:「B6:W20.9-14 LH」connects CGA350 アクセサリ

  • Upload
    vonga

  • View
    220

  • Download
    0

Embed Size (px)

Citation preview

Feature

Specification

Appearrance

BrassDouble Stage Regulator for Industrial Gases

  For High pressure

JET-Vc

Flow TemperatureMaterials

WeightBody Diaphragm Filter The others

15m3/h(nor) -5~40℃ C3771CR,

Fluororesin Sintered SUS C3604,Fluororesin 1.3kg~

http://nissantanaka.com

Flow Rate 0.25

0.20

0.15

0.10

0.05

0.00

Qm3/h (nor)(Nitrogen)0 2 4 6 8 10 12

P1: 13MPa

0.6

0.5

0.4

0.3

0.2

0.1

0

Qm3/h (nor)(Nitrogen)0 5 10 15 20 25 30

P1: 8MPa

Supply Pressure Effect0.6

0.5

0.4

0.3

0.2

0.1

0

P1 MPa 0 9 10 11 12 13 14 151 2 3 4 5 6 7 8

Q: 10L/minQ: 5L/minQ: 0L/min

Q: 50L/min

1. This Double Stage regulator eliminates the effect of supply pressure. 2. Connect several kinds of accessory like a flowmeter, needle valve, or prefered accesories. 3. Keeps gas purity because the diaphragm is used Teflon cover.4. Supplies a micro flow rate.5. Has a filter in the body. It eliminates the possibility of internal leakage.

(90)(88)(43)

W22-14RH

M16×1.5R OUT

IN

1/4"(Ø6.35)(90)(92)

M16×1.5R

OUT IN

W22-14 RH

(90)Outlet Connection F1(99),F3~F6(109)

M16×1.5R

1/4"(Ø6.35)

M16×1.5R

OUT

IN

W22-14R

JET-Vc70JET-Vc103JET-Vc50

JET - VcB - S - B5G G - - 1 0 0 0

※③:「B6:W20.9-14 LH」connects CGA350

アクセサリ

② ③ ④ ⑤①

T Relief Type 05 M16×1.5+1/4"Straight Nipple 1 O2,N2,ArK Retrieved Type 06 M16×1.5L+1/4"Straight Nipple 4 H2

71 Needle Valve M16×1.5+1/4"Straight Nipple 5 He72 Needle Valve M16×1.5L+1/4"Straight Nipple A Ar04 0.4MPa F1 20~160L/min Flowmeter+M16×1.5+1/4"Straight Nipple N N210 1.0MPa F3 4~25L/min Flowmeter +M16×1.5+1/4"Straight NippleF4 4~25L/min Flowmeter +M16×1.5L+1/4"Straight NippleF5 1~10L/min Flowmeter +M16×1.5+1/4"Straight NippleB1 W22-14 RHF6 1~10L/min Flowmeter+M16×1.5L+1/4"Straight NippleB2 W22-14 LH

B6 W20.9-14 LH

② Outlet Gauge Scale

③ Inlet Connection

④ Outlet Connection ⑤ Gas

④③

①Flow range

(L/min)Setting Pressure

(MPa)Temperature

(℃) Outlet Connection

F1 20~160 0.5

20

M16×1.5 10(1.0MPa) A(Ar),N(N2)F3 4~25 0.2

04(0.4MPa)

1(O2,N2,Ar),5(He)F4 M16×1.5L 4(H2)F5 1~10 0.2(0.1)※ M16×1.5 1(O2,N2,Ar),5(He)F6 0.1 M16×1.5L 4(H2)

Description Relief ValvePressure gauge(MPa) Maximum Pressure(MPa)

Inlet Connection Outlet Connection Scale of Flowmeter Gas Direction of InletInlet Outlet Inlet Outlet

In StockJET-Vc50 JET-VcB-ST-B5G10G-B105-11000

Relief 0~25

0~1.0

15

0.6W22-14RH

M16×1.5

-O2,N2,Ar

RightsideJET-Vc103 JET-VcB-ST-B5G04G-B171-11000

0~0.4 0.2NV M16×1.5JET-Vc303 JET-VcB-ST-B5G04G-B671-41000 W20.9-14LH He

JET-Vc110 JET-VcB-ST-B5G10G-B171-11000 0~1.0 0.6W22-14RH O2,N2,Ar

JET-Vc70 JET-VcB-ST-B5G04G-B1F3-11000 0~0.4 0.2 M16×1.5 4~25L/min Within 5 days JET-Vc51 JET-VcB-ST-B5G10G-B605-51000

Retrieved 0~25

0~1.0

15

0.6W20.9-14LH M16×1.5

-

He

Rightside

JET-Vc52 JET-VcB-ST-B5G10G-B206-41000W22-14LH

M16×1.5LH2JET-Vc203 JET-VcB-ST-B5G04G-B272-41000 0~0.4 0.2

NV M16×1.5LJET-Vc210 JET-VcB-ST-B5G10G-B272-41000

0~1.0 0.6JET-Vc310 JET-VcB-ST-B5G10G-B671-51000 W20.9-14LH NV M16×1.5 HeJET-Vc71 JET-VcB-ST-B5G04G-B1F5-11000

0~0.4 0.2W22-14LH M16×1.5 1~10L/min O2,N2,Ar

JET-Vc76 JET-VcB-ST-B5G04G-B2F4-41000 W22-14LH M16×1.5L4~25L/min

H2

JET-Vc77 JET-VcB-ST-B5G04G-B6F3-51000 W20.9-14LH He

JET-Vc78 JET-VcB-ST-B5G10G-B1F1-A10000~1.0 0.5 W22-14RH 20~160L/min

ArJET-Vc79 JET-VcB-ST-B5G10G-B1F1-N1000 N2

M16×1.5

M16×1.5Relief 0~25 15

Production on order

Rightside

※The setting pressure is 0.2MPa when F5 is used for O2,N2 and Ar. For Helium is 0.1MPa.

● ● We recommend 「S-LABO-S2 Series」if you look for the Double Stage regulator made of stainless.

Attachment of JET-Vc is different from JET-V’s. JET-Vc is 1/4” Straight Nipple.

※Outlet connection of F3,F4,F5,F6 is different from JET-V (JET-V was W12.5-20)

関連製品

Order information

Outlet Gauge

Outlet Connection

Inlet Connection

Relief ValveSpecification Description ②Outlet Pressure

① Relief Valve

③ Gas

Descriptions

http://nissantanaka.com

Accesories

Flowmeter

■ 1/4”Straight nipple SUS(QH630)

JPY1,700

■ Hose nipple NI (QC7171)

  

JPY320

 

Gas Pressure[MPa]

Scale[L/min] Accuracy

FN1R N2

0.10.1~1

F.S.5%

FH1R He 0.1~1FO1R O2 FH5R 0.5~5FA1R ArFN5R N2

0.5~5FO5R O2

FH1L H20.1~1

FA5R Ar

FH5L 0.5~5

Gas Pressure[MPa]

Scale[L/min] Accuracy

0.1 F.S.5%

Price : FN,FO,FA SeriesFH Series

:JPY18,000:JPY16,500

Related ProductsDouble Stage for purity gas

B2,S2 Series

Single Stage