19
LowCost Method to Measure Black Carbon with a Cell Phone Nithya Ramanathan [email protected]

Low$Cost(Method(to(Measure(BlackCarbon( …Cost(Method(to(Measure(BlackCarbon(withaCellPhone ((NithyaRamanathan’ [email protected](’ (Black Carbon Trends in California: Detection

  • Upload
    lamnga

  • View
    217

  • Download
    3

Embed Size (px)

Citation preview

Low-­‐Cost  Method  to  Measure  Black  Carbon  with  a  Cell  Phone  

   

Nithya  Ramanathan  [email protected]  

 

 Black Carbon Trends in California: Detection

Mostly Urban sites

Remote sites

2  Ramanathan et al, 2013: CARB 08-323

3  

Monitoring Black Carbon (BC) Using Mobile Phones

3

Innova:ons  §   Low-­‐cost  §   Works  with  any  camera  cellphone.  §   Real-­‐>me  repor>ng.  

4  

Why  it  Works:  Filter  color  correlated  to  BC  

4  1 Ramanathan et al. Atmospheric Environment 45(2011).

Absorp>on  in  λ  =  620-­‐740  nm  

BC  Loading  μg/cm

2   r2  =  0.9  

Collected  in:  California  and  India  

5  

Adjusts  for  Different  Ligh>ng  and  Cameras  

5  

Filter  

6  

Ramanathan, N., Lukac, M., Ahmed, T., Kar, A., Siva, P., Honles, T., Leong, I., Rehman, I. H., Schauer, J., Ramanathan, V. A cellphone based system for large scale monitoring of black carbon. Atmospheric Environment 45(2011) 4481-4487.

India and California: Comparison with Thermal Optical

Average error within 25%

Validation Study 1

Cell  ph

one  BC

 [μg/m

3 ]  

Reference  Instrument  EC  [μg/m3]  

India  

California  

7  

Comparison with 2 Thermal Optical Protocols (NIOSH, IMPROVE), Average error within 25%

Ramanathan, N., Khan, B., Leong, I., Lukac, M. Comparison Between Elemental Carbon Measured Using Thermal-Optical Analysis and Black Carbon Measurements Using a Novel Cellphone-Based System. American Geophysical Union 2011, San Francisco, CA.

Validation Study 2

Cell  ph

one  BC

 [μg/m

3 ]  

Thermal-­‐Op>cal  EC  [μg/m3]  

Collected  in:  EPA  Laboratory  

8  P. Siva et al. Unpublished.

Validation 3 (Blind Test)

11/Mar 14/Mar 17/Mar 20/Mar 23/Mar 26/Mar 29/Mar0

0.2

0.4

0.6

0.8

1

BC c

once

ntra

tion µ

g m

-3

Aeth - BCJJ - ECOR - ECCellphone BC

Maldives, March 2012: Comparison with Aethalometer and 2 Thermal Optical Methods

m=0.7  R²  =  0.98  

0  

1  

2  

3  

4  

5  

6  

7  

8  

9  

0.00   2.00   4.00   6.00   8.00   10.00   12.00   14.00  

Dev22  [BC]  ug/cm

2  

Aethalometer  [BC]  ug/cm2  

m=0.7  R²  =  0.99  

0  

1  

2  

3  

4  

5  

6  

7  

8  

9  

0.00   2.00   4.00   6.00   8.00   10.00   12.00  

Dev22  [BC]  ug/cm

2  

Aethalometer  [BC]  ug/cm2  Aethalometer  [BC]  μg  /  cm2  

Aethalometer  [BC]  μg  /  cm2  

Cell  Ph

one  [BC]  μg  /  

cm2  

Los Angeles (Fall, 2012): Comparison with Aethalometer

Validation Study 4 (Blind Test)

Cell  Ph

one  [BC]  μg  /  

cm2  

10  S. Tripathi et al. To be submitted.

Validation Study 5 (Blind Test)

India: Comparison with Thermal Optical (NIOSH)

Average error within 20%

11  S. Tripathi et al. To be submitted.

Validation Study 6 (Blind Test)

India: Comparison with PASS

Different  sites/sources/loca>ons:  •  Laboratory  se^ng:  Cookstoves  •  Kanpur, India: Highway Traffic, Power Plant, Biomass

Burning •  Maldives: South Asian plume  •  California:  Urban  outdoors  •  Jagdishpur,  India:  Indoor  biomass  burning,  outdoors    Comparison  with  different  methods:  •  Aethalometer  •  Thermal  Op>cal  (NIOSH,  IMPROVE)  •  PASS  

Valida>on  Studies  

13  

Measuring  Black  Carbon  in  Rural  Kitchens  in  India  

Monitoring Cookstoves and Vaccines

15  

Global Monitoring Networks

•  Environmental  Protec>on  Agency  •  Indian  Ins>tute  of  Technology,  Kanpur  •  Scripps  Ins>tute  of  Oceanography  •  University  of  Southern  California,  Global  Health  Ins>tute  

•  University  of  Wisconsin,  Madison    

Thanks  to  our  collaborators  

17  

Contact  Informa>on  

17  

Nithya  Ramanathan  [email protected]  hkp://nexleaf.org  

   

   

Funders:  Na>onal  Science  Founda>on,  Department  of  Energy,  United  Na>ons  Environment  Programme,  Qualcomm    

   

   

18  

Conversion  

18  

Loading  μg/cm2   Concentra>on  μg/m3  

Volume  Air  m3  

Filter  Size  cm2  

×  

÷  

19  

Sampler  

19