2
2 2 MB / MBA Patient Monitor 12.1"/10.4" color TFT display Standard parameters:ECG ,Sp0 2 .Resp,NIBP,2-Temp,PR, optional parameters:2-IBP,EtC0 2 ,CO 7 leads ECG analysis Respironics sidestream and mainstream EtC0 2 measurement for intubated and non-intubated patients Nellcor Oximax I EDAN Sp0 Sp0 pulse-tone modulation (Pitch Tone) OxyCRG for neonatal monitoring Arrhythmia analysis, ST segment analysis 120 seconds full-disc losure waveforms review Pacemaker detection Bi-directional communications with EDAN central monitoring system by wireless or wire network 96 Hours Trend Graph Powerful data storage capacity (96 hours graphic and tabular trends of all parameters,500 NIBP measurement results,60 alarm events) 60 USB data storage and review Nurse call Built-in rechargeable Li-ion battery Three channels printing 99 . 118 88 73 Comprehe ns i ve A rrh ythmi a Revi ew Large font Di sp l ay

M8 BROCHURE (PWM)-0111

Embed Size (px)

Citation preview

Page 1: M8 BROCHURE (PWM)-0111

2

2

MB / MBA

Patient Monitor • 12.1"/10.4" color TFT display

• Standard parameters:ECG ,Sp02 .Resp,NIBP,2-Temp,PR,

optional parameters:2-IBP,EtC02

,CO

• 7 leads ECG analysis

• Respironics sidestream and mainstream EtC02 measurement for

intubated and non-intubated patients

Nellcor Oximax I EDAN Sp0

Sp0 pulse-tone modulation (Pitch Tone)

OxyCRG for neonatal monitoring

Arrhythmia analysis, ST segment analysis

120 seconds full-disc losure waveforms review

• Pacemaker detection

• Bi-directional communications with EDAN central monitoring system

by wireless or wire network 96 Hours Trend Graph

• Powerful data storage capacity (96 hours graphic and tabular trends

of all parameters,500 NIBP measurement results,60 alarm events) 60

• USB data storage and review

• Nurse call

• Built-in rechargeable Li-ion battery

• Three channels printing

99 . 118 88 73

Comprehensive Arrhythmia Review Large font Display

Page 2: M8 BROCHURE (PWM)-0111

Medical Equipment Plus Contact Welton Bailey- 509-954-4382

[email protected]

New EDAN Dental Patient Monitors with CO2 capability and 12” HD screen with special WSDA promotional pricing for only $ 3295.00. Also available new Criticare monitors with CO2 and stand-alone CO2 monitors. Contact: Welton R. Bailey 509-954-4382 or email [email protected]

MS / MBA

Patient Monitor

Technical Specifications Safety

IEC60601-1 approved, CE marking according to

RESPIRATION Method Impedance between

R-F (RA-LL),R L(RA LA)

Resp. Rate Measurement and Alarm Range:

Accuracy ±3bpm

M0093/42/EEC

Dimension and Weight

Adull

Neo/Ped

O rpm -120rpm

O rpm -150rpm

Low Perfusion 0.03 % - 20 %

TEMPERATURE

Dimension: 320mm(W)x150mm(D)x265mm(H)

Weight: MS 4.1kg M8A 3.9kg

Operation Environment

Temperature: 5 - 40 ·c

Resolution

Accuracy

Gain Selection

NIBP

1 rpm

:t2 rpm

x0.25,x0.5, X1.x2,x3, x4,x5

Channel

Measuring Range

Sensor type

Resolution

Accuracy

2

o -50 ·c

YSI (B series) and CF-Fl

0.1·c

:1:0.1·c (20 - 45'C)

Humidity:

Power:

25% - 93 %( non-condensing)

AC 100 - 240 V ,50/60 Hz

Method

Mode

Oscillometric

Manual, Auto,Continuous

IBP(optional)

:1:0.n:10-25t . 45-5oc >

Performance Specifications

Display: 12.1"/10.4"color TFT ( MS 12.1"

MeasuringIntervalin AUTO Mode

1/2/3/4/5/10/15/30/60/90/120/240/480Min

Channel

Label

2

ART, PA, CVP, RAP,LAP,ICP, P1, P2

M8A 10.4")

Resolution:800x600 dots

Waveforms: 11wavefo rms maximum

Indicator: Alarm indicator

Power indicator

Charging indicator

ORS beep and alarm sound

Cuff Pressure measuring Range0-290mmHg

Pressure Resolution 1mmHg

Pressure Accuracy

Mean error ±5mmHg

Maximum Standard deviation s8mmHg

Overpressure protection Dual Overpressure protections

Adult 297±3mmHg

Static Pressure Measuring Range

-50-+300 mmHg (up to 350 mmHg)

Static Pressure Accuracy

±2% or 1mmHg whichis greater

Dynamical Pressure Measuring Range -50-+300 mmHg

Dynamical Pressure Accuracy

±2% or 1mmHgwhich is greater

Measuring and Alarm Range

Interface:

Battery:

Network port/USB port

Rechargeable Li-ion battery

Maximum 4.5 hours with full capacity

Pediatric 240±3mmHg

Neonatal 145:t3mmHg

PR

ART

PA

O - 300 (mmHg)

6 - 120 (mmHg)

Recall:

Alarm:

1-96 hours trend recall

3-level audible and visualalarm

Measuring range 40-240bpm

Resolution 1bpm

CVP/RAP/LAP/ICP -10 - 40 (mmHg)

P1/P2 -50 - 300 (mmHg)

Recorder: Built-in, thermal array

3 traces

Accuracy :t3bpm or 3.5% the maximum

Sp02

Resolution

CO,(optional)

1(mmHg)

Paper width: 48mm

Record speed: 25mm/s, 50mm/s

Waveform Sweep Speed: 6.2Smm/s, 12.Smm/s, 2Smm/s, SOmm/s

ECG

Measuring Range 0 - 100 %

Alarm Range 0 - 100 %

Resolut on 1 %

Accuracy

Method Infrared Absorption Technique

Measuring mode Sidestream or Mainstream

Measuring range

co, o - 150 mmHg