  • 1Spillsandoverfillsofregulatedsubstances(suchasgasolineordiesel)oftenoccurwhentheproductisbeingdeliveredintoastoragetank.Whenaspilloccurs,itcanseepintothedirt(orsoil)aroundastoragetank,possiblycontaminatinglocalwatersupplies.Contaminationofsoilorwatercanaffectthehealthofpeopleandnegativelyaffectourenvironment.

    Inthismodule,youwilllearnaboutthedifferentmethodsofspillandoverfillpreventionforastoragetanksystemandtheregulatoryrequirementsforyourstate.Spillandoverfillpreventionmethodsareintendedtopreventreleasesorspillsfromoccurringduringthedeliveryofproduct,suchasgasolineordiesel,toyourstoragetanksystem.

  • 2Topreventspillingassociatedwiththetransferofregulatedsubstances,suchasgasolineordiesel,toaneworupgradedstoragetanksystem,stateregulationsrequirethateachowneroroperatormustusespillcontainmentequipment(suchasacatchmentbasin)topreventreleaseofregulatedsubstanceswhenthetransferhosefromthetankertruckisdetachedfromthefillpipe.

    Topreventoverfillingassociatedwiththetransferofregulatedsubstances,eachowneroroperatormustuseoverfillpreventionequipmentthatautomaticallyshutsoffflowintothetankwhenthetankisnomorethan95%full,alertsthedeliverydriverwhenthetankisnomorethan90%fullbyrestrictingtheflowofproductintothetankortriggersahighlevelalarmaudibletothetransferoperator.

    Alternativespillandoverfillequipmentmaybeusedifitisdeterminedby,andapprovedinwritingbytheOfficeofStateFireMarshalltobenolessprotectiveofhumanhealthandtheenvironmentthanthesemethods.

    AUSTthatisfilledbytransfersofnomorethan25gallonsatonetimedoesstillrequirespillcontainment,butdoesnotrequireoverfillprevention.

    Wasteoiltanksmustalsobeequippedwithspillcontainmentdevicesatallfillandretrieval

  • 3Beforeproductisdeliveredtoatank,theowner,operatororpersonincharge(suchasadeliverydriver)shouldmakesurethatthevolumeavailableinthetankisgreaterthanthevolumeofproductbeingtransferredtothetank.

    Duringadelivery,theowner,operatororpersoninchargemustconstantlymonitorthetransferofproducttopreventoverfillingandspillingandensurethatdeliveryisbeingperformedinaccordancewithmanufacturerspecifications.

    Theowneroroperatormustensurethatspillpreventionequipmentiskeptclean,dryandinspectedmonthly.Priortodispensingproduct,thedeliverydriverorpersoninchargeshouldalsoverifythattheequipmentiscleananddry,beforetransferring.

  • 4Theowneroroperatormustensurethatallfilllinesforthestoragetanksystemareclearlymarkedtoindicatethetypeofregulatedsubstance,suchasunleaded87ordiesel,beingstored.Itisrecommendedthateachtankisadditionallymarkedtoindicatetanksize.

    Thefollowingmethodscanbeusedasproperlabeling: Installingapermanenttagorsignimmediatelyadjacenttothefillpipeswhichstates

    thesizeofthetankandthespecifictypeofsubstancestored;or, Applyingacolorcodethatconformstothefollowingrequirements:

    ColormarkingsinaccordancewithAPI1637ProductIdentification,mustbepaintedorplacedaroundthefillormanholecoverinamannerthatwillreadilyidentifythesubstanceinthetank;or,identificationinaccordancewithindustrystandardsorbusinesscolorcode

    Owners,operatorsorotherresponsiblepartiesarerequiredtoreport,investigate,andcleanupanyspillsandoverfillsthatoccur.

  • 5Spillbuckets,orspillcatchmentbasins,arelarge,drumshapedcontainersthatsurroundthefillportand,insomecases,thevaporrecoveryporttoastoragetankwhereahoseisconnectedfromtheproductdeliverytrucktothetankduringrefueling.

    Spillbucketscanrangeinsize,andifinstalledafterMay1,2003arerequiredtoholdaminimumof5gallonsofproduct.Bucketshavingcapacitiesupto25gallonsarecurrentlyinuse.Spillbucketsareinstalledtocontainorcatchdripsorspillsoffuelthatcanoccurduringproductdelivery.TheirintendedpurposeistheTEMPORARYstorage,orcontainmentofthespilledfueluntilitcanbeproperlycleanedup.

    Sometimes,fuelingstationscontainremotefills.Thismeansthatthedeliveryports,includingthespillbuckets,arelocatedawayfromthetopofthestoragetanks.Remotefillsaretypicallyusedatsmallerfacilities,facilitieswithhighervolumeorwheredeliverytruckscannotaccessthetopsofthestoragetanks.

  • 6SpillbucketsaredesignedtotemporarilycontainproductspillsthatmightoccurandareNOTdesignedtocontainproductforextendedperiodsoftime.Spillbucketsshouldhaveacapacitylargeenoughtocontainanyproductthatmayspillwhenthedeliveryhoseisuncoupledfromthefillpipe,andifinstalledafterMay1,2003arerequiredtoholdaminimumof5gallonsofproduct.

    AUSTthatisfilledbytransfersofnomorethan25gallonsatonetimedoes stillrequirespillcontainment,butdoesnotrequireoverfillprevention.

    Wasteoiltanksmustalsobeequippedwithspillcontainmentdevicesatallfillandretrievalpoints.

    Anyspillbucketrepairedorinstalledisrequiredtobetestedtoensuretheyareliquidtight.Ahydrostatictestmustbeperformedasfollows:1)Containmentistobefilledwithwatertoaheightthatcoversthehighestpenetrationby2inches.2)Minimalbackfillingthatmaybenecessaryforsupportofthecontainmentsumpisallowedpriortothetest.3)Testdurationis30minutesandperformedunderPerformanceAssuranceInspectionTimeandDateCertainrequirementswithnodropinwaterlevel.

  • Spillbucketsaretypicallyequippedwithavalvewhichallowsyoutodrainthecontainedproductbackintothetank.Ifwaterordebrisismixedinwiththeproductinthespillbucket,thenyoushouldNOTdrainthismixtureintothetank.Watermaycauseinternaltankcorrosion,dispensingproblems,orincreasetherequirementtoremovethecontaminatedwaterfromthetank.Worstofall,wateranddebriscancontaminatethefuelinthestoragetankandcouldcausedamagetocustomervehicles.

    Waterpresentinspillbucketswillalsoreducecapacityandmaycausemetalcomponentstocorrode.

    7

  • Yourspillbucketsmaybeequippedwithamanualpumpinsteadofadrainvalvethatallowsyoutopumptheproductbackintothetank.However,asmentionedpreviously,itisnotwisetoallowwaterordebristoenterthetank.Therefore,youshouldpumpthewater,product,anddebrismixtureoutofthespillbucketandplacethewasteinanappropriatedrumatyourfacility.Thenyoucanarrangeforproperdisposal.

    8

  • Itisveryimportanttoinspectthelidsofyourspillbucketstoensurethattheyremainingoodconditionandarenotallowingsurfacewatertoenter.Youshouldensurethatwhenthelidstoyourspillbucketsareclosed,thereisagoodsealandaretightlysecured.Somespillbucketshaverubbergasketsontheinsideofthelids.Youshouldensurethattherubbergasketsareingoodconditionandcreatesagoodseal.Inaddition,ensurethespillbucketlidisnottouchingthefillcap,asthiscoulddamagethefillpipe.

    Lastly,inspectyourspillbucketstoensurethattheyarestructurallysound.Cracks,holes,ordeformationstothespillbucketswillallowproducttoleakandcontaminatesoiland/orgroundwater.Onlyonegallonoffuelleakingeachweekfromapoorlymaintainedspillbucketcanresultinthousandsofdollarsincleanupcosts.

    9

  • Althoughnotrequired,itisrecommendedthatspillbucketsbeinspecteddailytoensuretheyareworkingproperlyandarebeingmaintainedcorrectly(or,thattheyarecleananddry).Theuseofachecklistmightbeausefulreminderofwhattolookforduringadailyinspection.Pleasetakeamomenttoreviewtherecommendedspillbucketoperationandmaintenancechecklist.Itisnotrequiredtouseacontractorforspillbucketinspections,howevertheirexperiencemaybehelpfulinrecommendingappropriatecorrectivemeasures.

    10

  • Overfillprotectionequipmentinstalledonundergroundstoragetankshelpspreventyourtanksfrombeingoverfilledduringproductdelivery.Overfillprotectionisdesignedto:

    Alertthetransferoperatorwhenthetankisnomorethan90%fullbyrestrictingtheflowintothetankandtriggeringahighlevelaudibleand/orvisualalarm;and

    Automaticallyshutoffflowintothetankwhenthetankisnotmorethan95%full.

    Wewilldiscussthethreetypesofoverfillprotectionforstoragetanks,whichare:1)Overfillalarms;2)Ballfloatvalves;and3)Automaticshutoffdevices.

    11

  • Thefirsttypeofoverfillprotectionisanoverfillalarm.AnoverfillalarmhasasensorlocatedinthestoragetankthatistypicallyconnectedtoamonitoringdevicesuchasanautomatictankgaugeorATG.

    Anoverfillalarmprovidesawarningthatcanbeseenand/orheardbythepersondeliveringtheproductwhentheproductinthestoragetankreaches90%ofthetankscapacity,oriswithinoneminuteofbeingoverfilled.

    12

  • Pleasetakeamomenttoreviewthebasicoperationandmaintenancechecklistforoverfillalarms.

    13

  • Thesecondtypeofoverfillprotectionisaballfloatvalve.Aballfloatvalve,alsocalledafloatventvalve,isinstalledattheventpipeinsidethetankandrestrictsvaporflowintoastoragetankasthetankgetsclosetobeingfull.Theballfloatvalveshouldbesetatadepthwhichwillrestrictvaporflowoutoftheventlineduringdeliveryat90%ofthetankscapacity.Asthetankfills,theballinthevalverises,restrictingtheflowofvaporsoutofthestoragetankduringdelivery.Theflowrateofthedeliverywilldecreasenoticeablyandshouldalertthedeliverypersontostopthedelivery.Forballfloatvalvestoworkproperly,thetopofthetankmustbeairtightsothatvaporscannotescapefromthetank.Everythingfromfittingstodrainmechanismsonspillbucketsmustbetightandbeabletoholdthepressurecreatedwhentheballfloatvalveengages.

    Itmaybedifficulttodeterminewhetherornotyouhaveaballfloatvalve,orifitisstillintactandfunctioningproperly.Youmightbeabletofindanextractorportfortheballfloatvalve,asillustrated.Otherwise,youwillneedtolookthroughyourpaperworktodeterminewhetheryourtankhasthisdevice.Youmaywanttoaskyourmaintenancecontractortoinspectthetankstotellyouwhichdeviceyouhave.

    Ballfloatventvalvesmustnotbeusedonanytypeofsuctionsystem.

    Pleasealsonote:Theuseofaballfloatvalveisnotrecommendedwhenafacilityisequippedwithremotefills.Insituationswhenashutoffdeviceisusedwitharemotefill,atrapdoororsimilardevicemustbeusedbeneaththefilladaptoronthestraightportionofthefillpipetopreventfuelfromshootingupoutofthestraightfillwhentheshutoffvalvecloses.Astandardfillcapisnotsufficienttocontainthepressurecreatedatthestraightfillwhentheshutoffvalvecloses.

    Ballfloatvalvesmayalsocompromisetheeffectivenessoftheflappervalveinanautomaticshutoffdevice.Ifballfloatvalvesarepresentorusedwithautoshutoffdevices,theymustbesettoengageat95%fullorhigher(nottoexceed98%)soasnottointerferewiththeoperationoftheautoshutoffdevice.Becauseoftheseshortcomings,ballfloatvalvesarenotapreferredmethodofoverfillprevention.

    14

  • Thethirdtypeofoverfillprotectionisanautomaticshutoffdevice.Anautomaticshutoffdevice,alsoknownasaflappervalve,isamechanicaldeviceinstalledinlinewiththedroptubewithinthefillpiperiser.Itslowsdownandthenstopsthedeliverywhentheproducthasreachedacertainlevelinthetank.Itshouldbepositionedsothatthefloatarmisnotobstructedandcanmovethroughitsfullrangeofmotion.Wheninstalledandmaintainedproperly,theshutoffvalvewillstoptheflowoffueltothestoragetankat95%ofthetankscapacityorbeforethefittingsatthetopofthetankareexposedtofuel.

    15

  • Pleasetakeamomenttoreviewthebasicoperationandmaintenancechecklistforautomaticshutoffdevices.Youmustuseaspecificallydesignedautomaticshutoffdeviceforoverfillprotectionifyourstoragetankreceivespressurizeddeliveries.Apressurizeddeliveryiswhentheproductbeingdeliveredintothestoragetankisforcedintothetankbysomemechanicalmeans,notgravityfed.

    16

  • Containmentsumpspreventreleaseofaregulatedsubstanceintotheenvironment.Theyareusedforconnectionsofpipingfromthetanktothedispenser.

    OnorafterMay1,2003,atankcontainmentsumpmustbeinstalledatthetankonallnewtankswithsubmersiblepumpsorAmericansuctionpipingsystems.Atankcontainmentsumpmustbealsobeinstalledwhenanexistingsubmersibleisreplacedwithanothersubmersible,orwhenpiping,flexconnectorsorothertransitionalcomponentsatthesubmersiblearereplaced.

    Alltankcontainmentsumpsmustconsistofafactorymanufacturedcontainmentthatisliquidtightonitssides,bottomandatanypenetrationsandiscompatiblewiththesubstanceconveyedbythepiping.Europeansuctionsystemsarenotrequiredtohavethiscontainment.

    Fornewdispenserinstallations(wheretherewerenonepreviously),andwhenanexistingdispenserisreplacedwithanotherdispenser,andequipmentatorbelowtheshearvalveisreplaced,underdispensercontainmentmustbeinstalled.Examplesofequipmentatorbelowtheshearvalveincludeflexconnectorsorrisersorothertransitionalcomponentsthatarebeneaththedispenserandconnectthedispensertothepiping.Europeansuctionsystemsarenotexemptfromthisrequirement.

    Containmentmustbemonitoredmonthlyforevidenceofareleasefromthetankandpiping,andmustbeinplaceatthesubmersiblepumporotherlocationwherethepipingconnectstothetank,wherethepipingconnectstoadispenser,andwheredoublewalledpipingthatisrequiredconnectswithexistingpiping.

    17

  • ThisconcludestheSpillandOverfillmodule.Youshouldnowhaveanunderstandingofcontrolmethodsusedtopreventspillingassociatedwiththetransferofregulatedsubstances,suchasgasolineordiesel,toaneworupgradedstoragetanksystem.Thisisreferredtoasspillprevention.Overfillpreventionreferstothepreventionofreleasesduringtransferofregulatedsubstancesbyrestrictingorstoppingthedelivery.