Neutron position sensitive detector
ITEP,Moscow
Goryachev V.S., Chernishov O.A., Kirin D.Yu.,Mikhailov K.R.,Polozov P.A., Prokudin M.S., Romanov D.V., Sharkov G.B., Stavinskiy A.V., Stolin V.L.,Zhigareva N.M.
Nantes 2014 1
p Λ - 0 0 + n -
p X X X X X X XX X X
Λ X X X X X XX X X
- X X X X XX X X
X X X XX X X
0 X X X X+X X+X
0 X X X+X X+X
+ XX X X
n X X
- X
only tracking ---photon------neutron-- 10 18(13) 18(13) photon + neutron (4) photon or neutron (5)
(2) Baryon femtoscopy matrix
Physical motivation for neutron detector
2
(1) Phase diagram for nuclear matter
3
Neutron detectors(1)
LANDLarge area detector for high-energy neutronsΔTn/Tn = 5.3% for neutrons of Tn = 1 GeVangular resolution: 0.2° for a flight path of 15 mεn ~100% for neutrons of Tn= 1 GeVεn ~60% for neutrons of Tn= 0.2 GeV 400 photomultipliers/n(!)
!
ELENS
Neutron energy range of 100 keV to 10 MeVangular resolution of less than 1 degreeεn =25% for neutrons of Tn=500 keVεn =40% for neutrons of Tn=1 MeVFlight path 1-2 mTime resolution 840 psPosition resolution ~7,5 сmNeutron energy is determined using ToF tecniqueVery good light-collection efficiency is required for the detection of these small signals, so a proper wrapping material and the tight fitting of the foil onto the plastic were important criteria for ensuring a sufficiently high-quality light connection.
Wrapping procedure let reduce energy threshold Foil (VM2000) has a good reflection coefficient of R > 97% for ≥ 400 nm and R = (98.5 ± 0.3)% at 430 nm
4
Neutron detectors(2)
εn =20-30% for neutrons of Tn=60-250MeV Time resolution ~ 250psecLiquid scintillator-> different signal shape for n/γ Large total volume V ~ 50 dm3 and small sensitive volume V ~ 4 dm3
[Tilquin I. et al., Nucl. Instrum. Methods A365, 1995,p.446 ] 5
Neutron detectors(3)
Cross-TalksIf the same neutron is registered in two or more detectors –the cross-talk effect occurs.Cross-talk: simulates registered of two or more neutrons in neighbor module leadingto a strong spurious correlation. In case of one-particle distributionthe cross-talk effects are usually small, but in femtoscopy measurementsthis effect is quite important and dangerous.
Cross-Talks
7
Required features for new created detector
• Neutron energy range of 3 MeV to 250 MeV
• Time resolution ~ 300 psec
(For L~2m->accuracy for neutron momentum 15-25 MeV/c)
• Position resolution one order better than module size (~ 1 cm)
• Modular structure of detector for corelation measurements
• Module shape acceptable for germetic installation -> to create germetic large acceptance detector
• Compact module(to be able to use it as a part of universal detectors within magnets)
9
Neutron detector (first prototype)-ITEP
Plastic Scintillator 96 * 96 * 128 mm3
Fiber: KYRARAY,Y-11,d =1mm,
wavelength shift
4 SiPM & Amplifier - CPTA(Golovin)
Efficiency (estimate) 15%
Beam tests of first prototypeDC1
Beam ofProtons
p=3GeV/c
DC2
Ndet
10
Amplitude spectrum
11
Neutron detector (first prototype)-ITEP
d (cm)R
=A
4/A
2space resolution for the first prototype ~ 2.5 cm
180cm
20cm
Distance from the target 240cm;Detector thickness 20cm
Fiber + SiPM
Neutron detector supermodule (78 detectors)
12
Neutron detector (second prototype)-ITEP
13
Front Side Back
Neutron detector (second prototype)-ITEP
14
Neutron Beam test of prototype@Nuclotron
Td= 4 GeV/nucleon
( )d C pn X
Calibration of neutron detector
Purpose of simulation – estimation difference between neutron coordinate and recoil proton coordinate.
In framework Geant4 n+detector interaction for different neutron energy was simulated. H/C ~ BC400 (1.103). 105 neutrons for each energy. Neutrons shoot to detector centre. Event selection criteria: one proton realize after first interaction.
15
Principal restriction for neutron coordinate resolution
Distribution of secondary protons
150MeV 300MeV
16
Simulation neutron detector (second prototype)-ITEP
17All selected events
Dependence of maximum deviation protons from deposit energies(neutron energy 150 MeV)
18
Back wall events and collision with nucleus events
Dependence of maximum deviation protons from deposit energies
19
Main events
Dependence of maximum deviation protons from deposit energies
20
Neutron energy, MeV
50 100 150 200 300
% selected events
18,8 18,0 17,4 17,6 18,2
mean deviation end of protons track, mm
1,2 4,7 9,5 14,9 24,3
maximum deviation protons, mm
5,7 25,3 50,2 80,2 90,0
Results of the simulations
Next step
Conclusions 1. Principal restriction for spatial resolution for detector
< 1 cm at neutron energy < 150 MeV. 2. Expected spatial resolution for created module of
detector less than 1,5cm.
LANS(LINP-1980) large acceptance neutron spectrometerV.N.Baturin et al., LINP-594,1980 V(LxLyLz)=200x200x1000mm3
στ=2nsecεn =35% for neutrons of Tn=300MeV2 neutrons in 1 module register like 1 neutronPosition resolution – module size
Neutron detectors(1)
24
1.scintillator 2.lightguide3.photomultipliers 4.photodiodes5. voltage divider6.magnetic screen 7. spring