Top Meters Fill/Drain Point Fill/Drain Point Manifold length - see table Valve - 85mm Boiler Return Boiler Flow Connect to switch live demand* N 24V Uponor Actuators Pump (by others) B A 2 Port Motorised Zone Valve Connect to boiler demand. (refer to boiler manufacturer for details). N Bypass valve (by others) Mechanical Schematic No Water Temperature Control Ref: NWT-1.0A © Copyright Uponor Limited Copyright in this drawing belongs to Uponor Limited. This drawing may not be used, sold, licensed, transferred, copied or reproduced in whole or in part or in any manner or form other than with the prior written consent of Uponor Limited. Uponor reserve the right to alter specifications and operating parameters for all their systems at any time as part of their policy of continuous product development. * Refer to air temperature electrical schematic for connection. Manifold Length 2 Port 147mm 3 Port 197mm 4 Port 247mm 5 Port 297mm 6 Port 347mm 7 Port 397mm 8 Port 447mm 9 Port 497mm 10 Port 547mm 11 Port 597mm 12 Port 647mm The height of the manifold is 340mm and needs to be mounted at least 300mm from the floor. Notes, 1) A bypass is recommended on the primary circuit. 2) The drawing excludes isolating & regulating valves for clarity. 3) All items to be installed in accordance with manufacturer's instructions and current best practices.

No water tempature control

Embed Size (px)

DESCRIPTION

https://www.uponor.co.uk/~/media/countryspecific/uk/support/no-water-tempature-control.pdf?version=1

Citation preview

Page 1: No water tempature control

Top Meters

Fill/Drain

Point

Fill/Drain

Point

Manifold length - see tableValve - 85mm

Boiler

Return

Boiler

Flow

Connect to switch

live demand*

N

24V Uponor

Actuators

Pump

(by others)

BA

2 Port Motorised

Zone Valve

Connect to boiler

demand. (refer to

boiler manufacturer

for details).

N

Bypass

valve

(by others)

Mechanical Schematic

No Water Temperature Control

Ref: NWT-1.0A

© Copyright Uponor Limited

Copyright in this drawing belongs to Uponor Limited.

This drawing may not be used, sold, licensed,

transferred, copied or reproduced in whole or in part or

in any manner or form other than with the prior written

consent of Uponor Limited.

Uponor reserve the right to alter specifications and

operating parameters for all their systems at any time as

part of their policy of continuous product development.

* Refer to air temperature electrical schematic for

connection.

Manifold Length

2 Port 147mm

3 Port 197mm

4 Port 247mm

5 Port 297mm

6 Port 347mm

7 Port 397mm

8 Port 447mm

9 Port 497mm

10 Port 547mm

11 Port 597mm

12 Port 647mm

The height of the manifold is 340mm and needs to be

mounted at least 300mm from the floor.

Notes,

1) A bypass is recommended on the primary circuit.

2) The drawing excludes isolating & regulating valves for

clarity.

3) All items to be installed in accordance with

manufacturer's instructions and current best practices.