Upload
others
View
3
Download
0
Embed Size (px)
Citation preview
高端低压电气系统解决方案专家
Photovoltaic Industry Low Voltage
Electrical Equipment Solution
高端低压电气系统解决方案专家
@Nader
September 25, 2018|slide 2
CONTENTS
Part 02 Photovoltaic solution
Part 01 PV Industry condition
Part 03 Industry trend
Part 04 Typical Cases
高端低压电气系统解决方案专家
• The global PV market had a strong growth in 2018, with the newly installed capacity of more than 100GW, a year-on-year growth
of 33.6%, and a total of PV capacity up to 403GW
30 38 38.4 49.4 40.6 78
103 86 90.4 96.4
70 108
146.4
195.8 236.4
306.4
409
495.4
585.8
682.2
26.7%
1.1%
28.6%
-17.8%
29.6%
33.6%
-16.5%
5.1%
6.6%
-30.0%
-20.0%
-10.0%
0.0%
10.0%
20.0%
30.0%
40.0%
50.0%
60.0%
70.0%
80.0%
0
100
200
300
400
500
600
700
800
2011 2012 2013 2014 2015 2016 2017 2018 2019 2020
Newly installed capacity of global PV power generation from 2010 to 2020
New installation(GW)
Accumulated installation(GW)
Year-on-year growth rate of new
installed capacity
Source: public information
PV Industry Global installation capacity
@Nader
September 25, 2018|slide 3
China
44%
USA
19%
Japan
17%
India
6%
Others
14%
New PV capacity of each country
2017
高端低压电气系统解决方案专家
• Renew able Energy Capacity is doubled in last 4 Years.
• Target up to year 2022 is 175GW (as per International
Solar Alliance summit 2018). Now upgraded 227 GW
• Solar power capacity increased by over 8 times in last 4 years from
2630MW to 22000 MW with record 100 billion+ units of renew
electricity generated last year.
• Wind power capacity increase by 1.6 times in last 4 years from
21000 MW to 34000 MW.
• Transparent bidding process of Government led to significant
reduction in per unit cost of Solar & Wind power.
PV Industry in India
source:MNRE
高端低压电气系统解决方案专家
• Just five states Andhra Pradesh , Gujarat, Rajasthan , Telangana & Karnataka host two
thirds (more than 67%) of India’s total Solar power installation capacity.
Top solar power producing states of India
source:MERCOM
高端低压电气系统解决方案专家
Power Grid Operator EPC
PV Industry Operators
source:MERCOM
EPC
高端低压电气系统解决方案专家
@Nader
September 25, 2018|slide 7
CONTENTS
Part 02 Photovoltaic solution
Part 01 Industry condition
Part 03 Industry trend
Part 04 Typical Cases
高端低压电气系统解决方案专家
@Nader September 25, 2018|slide 8
Photovoltaic module Combiner box
Inverter
Grid transformer Power transmission
network
The large-scale grid PV power station usually has photovoltaic panel PV inverter and grid transformer
Inverter boost integrated
solutions
PV Solution equipment
高端低压电气系统解决方案专家
@Nader September 25, 2018|slide 9
Centralized PV
Photovoltaic power generation system based on high-power photovoltaic inverter (over
500kW)
The location of the site is flat and the PV modules are generally oriented towards the same
direction without any blockage
Generally ≥5MW even GW level
Power generation with 10KV or 35KV access to power grid,far from load, unable to be
consumed locally
String PV
Photovoltaic module≤5 sets connected to grid inverter by string form
Flexible location,installed in hills,roof etc. Module orientation is
inconsistent
Different capacity,less than 1 MW operable
Power generation with 10KV or 35KV access to power grid,far from load,
unable to be consumed locally
Photovoltaic solution centralized & string
高端低压电气系统解决方案专家
@Nader September 25, 2018|slide 10
DC arc is more difficult to extinguish,
so DC MCB for PV use only is more
preferred to keep safe.
NDG3 1000VDC Isolator, rated
around 125A-800A
NDU2Z SPD for1100VDC only,
voltage protection level ,4.3kA,
maximum discharge current 40kA
Combiner box
AC contactor is used the main circuit. AC contatorNDC1, Rated current, 1050~2650A。
NDC5K Vacuum contactor contacts in vacuum room,smaller size with same
characteristic.
NDM3EX MCCB specially designed for PV inverter, smallest size in the LV industry,
Icu=70KA, 400VAC,leading the LV industry.
Inverter
ACB is applied in LV side
NDW2, rated voltage 690V,Icu=85kA(frame
3200A),cost-effective products with good
performance
NDU1 SPD Operating voltage550VAC,Maximum
discharge current reach 65kA,protecting lightning
overvoltage.
Transformer
1100VDC/690VAC Centralized photovoltaic power plant
LV distribution protection system
Centralized Photovoltaic generation
PV cells Combiner box Grid inverter Transformer
GRID
11
00
V D
C
69
0V
AC
高端低压电气系统解决方案专家
@Nader September 25, 2018|slide 11
NDM3Z-250V MCCB specially designed
for 1500VDC,Icu=20kA
NDM5Z-400 is the latest developed DC
MCCB,rated voltage 1500V,double
contacts, leading the industry
NDG3 1500VDC Isolator rated around
250A-400A
AC contator NDC1, AC contactor is used the main circuit. Rated current,
1050~2650A。NDC5K Vacuum contactor contacts in vacuum room,35% smaller
than normal contactors with better characteristics.
DC MCCB NDM5Z, 1500VDC,
NDW2GZ-2000 , Isolator with 1500VDC
ACB NDW2, high performance at breaking capacity
ACB NDW2 Acquiring patent of arc
quenching system, it increases breaking
capacity and electrical life much more.
Rated voltage, 1000V
Optimising of operation structure,involving
shaft sleeve material
Electrical life :10000; mechanical:15000.
PV cells Combiner box Grid inverter Transformer
GRID
1500VDC/800VAC Centralized photovoltaic power plant
LV distribution protection system
Centralized Photovoltaic generation
Combiner box
Inverter
Transformer 15
00
V D
C
10
00
V A
C
10
00
V A
C
高端低压电气系统解决方案专家
@Nader September 25, 2018|slide 12
NDG3V-50 DS
1100VDC, Rated current≤50A,used
for inspection and isolation.
small size
IP65
NDU2Z SPD for1100VDC only,voltage
protection level ,4.3kA,maximum
discharge current 40kA
NDM3 MCCB
Rated voltage 690VAC,125~1600A。
NDM3-400, 690VA Icu=20kA,
NDM5 MCCB Double contacts
The extinguishing ability of short circuit is greatly enhanced
At 690VAC Icu40kA Smallest size in the industry
Inverter NDW2 rated voltage 690V,Icu=85kA(frame
3200A),cost-effective products with good
performance
NDU1 SPD continuous operating voltage
550VAC,maximum discharge voltage 65kA
PV cells Combiner box Grid inverter Transformer
GRID
1100VDC/690VAC String photovoltaic power plant
LV distribution protection system
String Photovoltaic generation
Combiner box
Transformer
11
00
V D
C
69
0V
AC
69
0V
AC
高端低压电气系统解决方案专家
@Nader September 25, 2018|slide 13
NDG3V-50 DC DS 1100~1500V
High breaking capacity,
1500VDC Rated current 32A,used for
inspection and isolation.
small size
IP65
NDM3A MCCB applied in inverter AC
NDM3A-250/400/630 800VAC, Icu=30kA,
NDM5 MCCB Double contacts
The extinguishing ability of short circuit is greatly enhanced
At 800VAC Icu50kA Smallest size in the industry
NDG3-160 /315 @ 1000VAC
ACB NDW2 Acquiring patent of arc
quenching system, it increases breaking
capacity and electrical life much more.
Rated voltage, 1000V
Optimising of operation structure,involving
shaft sleeve material
Electrical life :10000; mechanical:15000.
15
00
V D
C
80
0V
AC
80
0V
AC
1500VDC/800VAC String photovoltaic power plant
LV distribution protection system
String Photovoltaic generation
PV cells Combiner box Grid inverter Transformer
GRID
Inverter
Combiner box
Transformer
高端低压电气系统解决方案专家
@Nader September 25, 2018|slide 14
Grid connected inverter
Combiner box
PV solution Household distributed photovoltaic
PV cells Switch box Inverter
Grid connection Two-way
meter
MCB, overvoltage protector
DC MCB
GRID
DC SPD SPD SPD Grid connected box
LOAD
PV DC DS
高端低压电气系统解决方案专家
@Nader
September 25, 2018|slide 15
CONTENTS
Part 02 Photovoltaic solution
Part 01 Industry condition
Part 03 Industry trend
Part 04 Typical Cases
高端低压电气系统解决方案专家
VOLTAGE
1500VDC 1000VAC
Inverter & transformer integrated
Integrated solution more economic
Giant power
String PV system: 7.5 MW Centralized PV system:
3/3.5 MW
Smart
Remote control , Cloud Processing , lesser
Downtime
Foresee the PV future outline
PV system
高端低压电气系统解决方案专家
2016 2017 2018 2020 2022 2025
Others 0.5% 0.5% 1.0% 2.5% 3.0% 5.0%
Distributed power
station12.0% 21.0% 33.0% 45.0% 43.0% 40.0%
Large surface power
station88.0% 78.5% 66.0% 52.5% 54.0% 55.0%
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100% Inverter • string inverter rising
Combiner box • AC rising
• DC decreasing
Transformer
Environment
• Highland
• Thunder
• High temp,humidity
• Frost
AC MCCB increased
DC MCCB decreased
High breaking capability
DC isolating switch
demand increased
Trend Installation PV
高端低压电气系统解决方案专家
2016 2017 2018 2020 2022 2025
Micro inverter 1.0% 1.5% 2.0% 3.0% 3.0% 3.0%
String inverter 32.0% 37.5% 40.0% 45.0% 43.0% 42.0%
Centralized inverter 62.0% 54.0% 50.0% 41.0% 39.0% 39.0%
Distributed inverter 5.0% 6.0% 8.0% 11.0% 15.0% 16.0%
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
Market share of different types of inverter
Trend Installation PV
高端低压电气系统解决方案专家
• High voltage reduce the line loss and the amount of copper
• 1500VDC;
• 800,1000VAC;
1500V DC Disconnection
switch、DC MCCB
1000VAC ACB、DC
MCCB, Contactor
2016 2017 2018 2020 2022 2025
Others 3.0% 4.0% 6.0% 8.0% 15.0% 25.0%
1000V 92.0% 85.0% 76.0% 67.0% 58.0% 45.0%
1500V 5.0% 10.0% 18.0% 25.0% 27.0% 30.0%
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
Market share of different system voltage levels
Trend High voltage
高端低压电气系统解决方案专家
• String Inverter 90 KW / 120 KW
• Centralized system 3 MW / 3.5 MW available • String system 1500V/32A
Disconnection switch
• Centralized
system1500VDC/400A
DC MCCB
• 1000V AC/1600A MCCB
Contactor
AC side, Icu higher
Smaller size
2016 2017 2018 2020 2022 2025
x<10kW 4.9% 5.9% 6.9% 9.6% 10.1% 10.5%
10kW<x<100kW 35.4% 36.6% 37.4% 39.6% 39.7% 40.5%
100kW<x<1000kW 29.2% 35.7% 32.0% 21.0% 20.3% 18.9%
x>1000kW 20.5% 21.8% 23.7% 29.8% 29.9% 30.1%
0%
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
Market share of different inverter power
Trend High power
高端低压电气系统解决方案专家
@Nader
September 25, 2018|slide 21
CONTENTS
Part 02 Photovoltaic solution
Part 01 Industry condition
Part 03 Industry trend
Part 04 Typical Cases
高端低压电气系统解决方案专家
NDM5Z DC1200V successful enters into
CGN, Over 300MW of procurement has been
achieved , In 2016,Nader have signed the
purchase contract with ShenZhen
Winline/KSTAR/Kelong/Chint,etc.
Nader DC products have entered in
more than 20 EPC
(TBEA/GCL/TALESUN/LINGYANG/Jinko/TianHe ,et
c.)used in combiner box/inverter/ substation;
Typical cases EPC Cooperation
高端低压电气系统解决方案专家
Strategic cooperation with core companies in
PV industry. Providing whole product solution
of PV industry.
Typical cases equipment providers cooperation
Nader products
高端低压电气系统解决方案专家
This project locates at QingHai XiTie mountain, It's the first PV project's altitude more than 3,000 meters in
China. This is the first PV project in such high altitude and tough environment. Nader provided solution for
all LV distribution system protection.
EPC:CGN
The first PV station above on the 3000M in China.
Application
100MW inverter/combiner box
Main products NDM3Z MCCB
Typical cases QingHai XiTie mountain PV project 100MV
高端低压电气系统解决方案专家
The solar plant in Rajgarh can electrify 26000 homes considering daily consumption of 5 KWH
Nader PV Projects in India 10 MW Projects in near Madhya Pradesh
Builder (EPC):
ACME Solar Holdings Limited
Date:May-18
Frame Size: 125, 250, 400, 630, 800
Rated operational Current: 16A- 800A
Poles:2P/3P/4P
Rated Voltage: DC500V(2P),
DC750V(3P), DC1000V(4P)
Isolation Voltage: 1000V
breaking Capacity:
Ics=100%Icu=40KA
Applied products
NDM3Z series MCCB
高端低压电气系统解决方案专家 高端低压电气系统解决方案专家
DC 1500V, AC 1000V system
Nader PV Projects in India 50 MW Solar Projects in Projects in Chincoli, Karnataka
@Nader
June 27, 2018|slide 32
Applied products NDM3 DC1500V/AC1000 MCCB
NDG3 series switch
NDW2 series ACB
Application place
50MW combiner box/inverter
Builder (EPC): ReNew Power Ventures Pvt Ltd
Woner: Indian conglomerate LN Bangur Group
Date:Feb-17
高端低压电气系统解决方案专家 高端低压电气系统解决方案专家
Nader PV Projects in India 150 MW Solar projects in the Indian states of Telangana and Punjab
Applied products NDM3 MCCB
NDG3 series switch
NDW2 series ACB
1 Application place
150MW combiner box/inverter
Builder (EPC): Mytrah Energy .Ltd
Date:Aug-16
高端低压电气系统解决方案专家
@Nader September 25, 2018|slide 28
Internationalization Optimization for top 500 enterprises of the global
高端低压电气系统解决方案专家 高端低压电气系统解决方案专家
@nader
September 25, 2018|slide 29
——高端低压电气系统解决方案专家——
@Nader
September 25, 2018|slide 29