3
Argent 3, Castellbisbal - 08755 Barcelona Oddział w Polsce: Silesia Office Center Tel. (34) 93 6821300 - FAX (34) 93 6820975 41-500 Chorzów, ul. Katowicka 47 www.synthesiainternacional.com Biuro : +48 730 507 380 www.synte.pl [email protected] CASE STUDY Date of publication: June 2019 OPIS Implementation of polyurethane foam application on the ceiling and attic of a residential building. System: Poliuretan® Spray S-OC-006 Place of application: Greater Poland Implementation time: 2 days, June 2019. In June 2019, the company POWERLUK from Osiek performed insulation with open-celled foam in the single-family home. The property was fully prepared to install the application: all works were completed in the previous year, and the tile had relative humidity with the manufacturer's recommendations. The building uses the best insulation materials (windows, doors, polystyrene) and additionally a supply and exhaust recuperation system. The investor ordered the insulation of the ceiling from the bottom and the utility attic with material that will insulate the heat and suppress the noise in the same time. The POWERLUK proposed material from Synthesia Technology Poliuretan Spray S-OC-006 with an average density of 7 ± 1 kg / m3. The insulating material complies with EN 14315-1, and has a sound absorption factor of 0.5, and an aging lambda of 0.038 (W / mK). The results of the laboratory lambda’s tests which were made immediately after spraying - show a value of 0.03585 (W / mK), what means that the foam does not change the insulating properties for long time. POLIURETAN® SPRAY S-OC-006 POLAND

POLIURETAN SPRAY S -OC 006 POLANDsynte.pl/wp-content/uploads/2019/07/case_study_pssoc006...Poliuretan Spray S-OC-006 with an average density of 7 ± 1 kg / m3. The insulating material

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

Page 1: POLIURETAN SPRAY S -OC 006 POLANDsynte.pl/wp-content/uploads/2019/07/case_study_pssoc006...Poliuretan Spray S-OC-006 with an average density of 7 ± 1 kg / m3. The insulating material

Argent 3, Castellbisbal - 08755 Barcelona Oddział w Polsce: Silesia Office Center Tel. (34) 93 6821300 - FAX (34) 93 6820975 41-500 Chorzów, ul. Katowicka 47 www.synthesiainternacional.com Biuro : +48 730 507 380 www.synte.pl [email protected]

CASE STUDY

Date of publication: June 2019

OPIS

Implementation of polyurethane foam application on the ceiling and attic of a residential building.

System: Poliuretan® Spray S-OC-006

Place of application: Greater Poland

Implementation time: 2 days, June 2019.

In June 2019, the company POWERLUK from Osiek performed insulation with open-celled foam in the single-family

home. The property was fully prepared to install the application: all works were completed in the previous year, and

the tile had relative humidity with the manufacturer's recommendations. The building uses the best insulation

materials (windows, doors, polystyrene) and additionally a supply and exhaust recuperation system.

The investor ordered the insulation of the ceiling from the bottom and the utility attic with material that will insulate

the heat and suppress the noise in the same time. The POWERLUK proposed material from Synthesia Technology

Poliuretan Spray S-OC-006 with an average density of 7 ± 1 kg / m3. The insulating material complies

with EN 14315-1, and has a sound absorption factor of 0.5, and an aging lambda of 0.038 (W / mK). The results of the

laboratory lambda’s tests which were made immediately after spraying - show a value of 0.03585 (W / mK), what

means that the foam does not change the insulating properties for long time.

POLIURETAN® SPRAY S-OC-006 POLAND

Page 2: POLIURETAN SPRAY S -OC 006 POLANDsynte.pl/wp-content/uploads/2019/07/case_study_pssoc006...Poliuretan Spray S-OC-006 with an average density of 7 ± 1 kg / m3. The insulating material

Argent 3, Castellbisbal - 08755 Barcelona Oddział w Polsce: Silesia Office Center Tel. (34) 93 6821300 - FAX (34) 93 6820975 41-500 Chorzów, ul. Katowicka 47 www.synthesiainternacional.com Biuro : +48 730 507 380 www.synte.pl [email protected]

CASE STUDY

Date of publication: June 2019

"

According with the arrangements with the investor, the entire area of 310 m2 was covered with foam with thickness

of 20 cm.

„ During one of the works in the past years we had an unpleasant situation. Wanting to accommodate

investor, we approached his request to apply foam up to 20 cm. It was important to him, because

the hooks (esy) were prepared for the GK grate, and he did not want to cut in the foam to mount

the profiles.

Unfortunately, we met the complications during the reception the project by the construction manager. We were reminded that there is 18 cm in one place and 19 cm in the other. Although the average thickness was 20 cm they didn’t want to agree with us, the reference to EN14315-2 also did not help. We had to add another layer - an additional work day and more material consumption. From this situation we are more careful with signing a contract, for example, 20 cm, this is for us the minimum value of insulation. " - Łukasz Tomczak, owner of the POWERLUK company

Page 3: POLIURETAN SPRAY S -OC 006 POLANDsynte.pl/wp-content/uploads/2019/07/case_study_pssoc006...Poliuretan Spray S-OC-006 with an average density of 7 ± 1 kg / m3. The insulating material

Argent 3, Castellbisbal - 08755 Barcelona Oddział w Polsce: Silesia Office Center Tel. (34) 93 6821300 - FAX (34) 93 6820975 41-500 Chorzów, ul. Katowicka 47 www.synthesiainternacional.com Biuro : +48 730 507 380 www.synte.pl [email protected]

CASE STUDY

Date of publication: June 2019

"

In this case, the surface was easily accessible: a flat teriva ceiling, and a gable roof with a bay window (full boarding). During this implementation the company POWERLUK broke an absolute performance record, achieving 278 m2 from one set!

„During difficult aplication, when a man stands on one leg on the scaffolding, everyone only looks

to make fulfill the space by foam. In this case, we had a very grateful surface. As always, we counted

the meters of sprayed foam - in this way we check the actual performance of the set and the efficiency

of the dispensing device. Nobody expected it will be almost 280 m2! This is the biggest efficiency we

have ever applied.”

The average air temperature during the implementation period was 20 ° C.