RTN 600 Configuration-A

Embed Size (px)

Citation preview

  • 7/28/2019 RTN 600 Configuration-A

    1/77

    www.huawei.com

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

    2013/4/12 Security Level:INTERNAL

    OptiX RTN 600 Configuration

    Using the T2000 and T2000 Web LCT

  • 7/28/2019 RTN 600 Configuration-A

    2/77

    www.huawei.com

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved.

    2013/4/12 Security Level:INTERNAL

    OptiX RTN 600 Configuration

    Using the T2000 and T2000 Web LCT

  • 7/28/2019 RTN 600 Configuration-A

    3/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 2Page 2

    Foreword

    Huawei provides NE-level, subnet-level and network-level

    management systems for the RTN 600 series products.

    This course describes the NE-level management system OptiX

    iManager T2000 Web LCT and the subnet-level management

    system OptiX iManager T2000.

  • 7/28/2019 RTN 600 Configuration-A

    4/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 3Page 3

    Reference

    Digital Microwave Communication

    principles

    OptiX iManager T2000 Management

    System Solution V2.31

    OptiX iManager T2000 Web LCT

    Installation Guide and User Guide

  • 7/28/2019 RTN 600 Configuration-A

    5/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 4Page 4

    Objectives

    Upon completion of this course, you will be able to:

    Describe the functions of the T2000 and the T2000 Web LCT.

    Install the T2000 Web LCT.

    Configure services and protection by using the T2000 and the

    T2000 Web LCT.

  • 7/28/2019 RTN 600 Configuration-A

    6/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 5Page 5

    Contents

    1. Introduction to Networks

    Management Systems

    2. Introduction to T2000 Web LCT

    3. Introduction to the T2000

  • 7/28/2019 RTN 600 Configuration-A

    7/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 6Page 6

    Comprehensive Management

    System Solution

    iManager T2000 iManager T2000

    iManager T2100

    OSS or integrated

    NMS

    MMLMML MML

    NE

    management

    layer

    Network

    management

    layer

    Service

    management

    layer

    Qx Qx

    NE layer

    iManager T2100

    iManager T2000

    CORBA

    iManager T2000

    Integrated NMS & OSS

    CORBA CORBA

    LCT QxQx

  • 7/28/2019 RTN 600 Configuration-A

    8/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 7Page 7

    Introduction to Management SystemsThe orientation of each management system is as follows:

    iManager T2000 LCT The T2000 local craft terminal (LCT) realizes the local maintenance and

    equipment turn-up of Huawei OptiX products.

    iManager T2000

    The iManager T2000 (T2000 for short) is a subnet management system (SNMS)

    for transport networks. The T2000 manages the full series of Huawei OptiX

    products. The T2000 supports all functions of the NE layer and some of the

    network layer management functions.

    iManager T2100

    The iManager T2100 (T2100 for short) is a network-level management system

    that uniformly manages the full series of Huawei OptiX products. It manages

    large-scale optical transport networks in a uniform manner.

    iManager MDS

    The iManager MDS (MDS for short) is a business-level management system for

    transport networks. It assists users to plan and simulate an optical transport

    network.

  • 7/28/2019 RTN 600 Configuration-A

    9/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 8Page 8

    Contents

    1. Introduction to Management Systems

    2. Introduction to the T2000 Web LCT

    3. Introduction to the T2000

  • 7/28/2019 RTN 600 Configuration-A

    10/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 9Page 9

    Contents

    Introduction to theT2000Web LCT

    2.1 Main Characteristics

    2.2 Application Scenario

    2.3 Installation Guide

    2.4 Connecting to NEs

    2.5 Configuration Operations

  • 7/28/2019 RTN 600 Configuration-A

    11/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 10Page 10

    T2000 Web LCT Main Characteristics

    The characteristics of the T2000 Web LCT are as

    follows:

    Web-based solution

    Per-NE configuration and maintenance

    Access to a local NE through a LAN/RS 232

    Access to a remote NE through DCC

    Management of NEs of various types

    Concurrent login to a maximum of 32 NEs

    Integration with the T2000, T2100 or third-

    party management system

  • 7/28/2019 RTN 600 Configuration-A

    12/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 11Page 11

    T2000 Web LCT Function

    The T2000 Web LCT provides the following NE-layer management functions:

    Service configuration (including PDH and SDH microwave services)

    Protection configuration (intermediate frequency protection, SNCP,

    LMSP)

    Setting and query of the intermediate frequency attributes Setting and query of the radio frequency attributes

    Data services (the 10M/100M fast Ethernet transparent transmission

    board EFT4 is supported)

    Setting and viewing of alarms and performance data Communication and security

  • 7/28/2019 RTN 600 Configuration-A

    13/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 12Page 12

    Contents

    Introduction to the T2000 Web LCT

    2.1 Main Characteristics

    2.2 Application Scenario

    2.3 Installation Guide

    2.4 Connecting to NEs

    2.5 Configuration Operations

  • 7/28/2019 RTN 600 Configuration-A

    14/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 13Page 13

    T2000 Web LCT Application ScenarioStand-alone

    The equipment maintenance personnel installs the

    T2000 Web LCT on a PC.

    The equipment maintenance personnel manages local

    or remote NEs by using the T2000 Web LCT.

  • 7/28/2019 RTN 600 Configuration-A

    15/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 14Page 14

    T2000 Web LCT Application Scenario

    Integrated

    The personnel at the network operations center install the EMS or NMS on a PC.

    Install the T2000 Web LCT as a part of the EMS. The NMS need not be installed.

    The personnel at the network operations center starts the T2000 Web LCT by

    using the EMS or NMS client.

    NE network

    DCN

    NMS

    EMSEMS

    NE network

  • 7/28/2019 RTN 600 Configuration-A

    16/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 15Page 15

    Contents

    Introduction to the T2000 Web LCT

    2.1 Main Characteristics

    2.2 Application Scenario

    2.3 Installation Guide

    2.4 Connecting to NEs

    2.5 Configuration Operations

  • 7/28/2019 RTN 600 Configuration-A

    17/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 16Page 16

    T2000 Web LCT Installation Guide

    Pre-installation

    Configuration requirements

    The T2000 Web LCT runs on the Windows operating system.

    Hardware requirements

    CPU: Pentium III 700 MHz or higher

    RAM: 256 MB (recommended 512 MB or higher)

    Monitor: 1024 x 768 resolution

    Serial port: RS 232

    Ethernet port: 10M/100M

  • 7/28/2019 RTN 600 Configuration-A

    18/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 17Page 17

    T2000 Web LCT Installation Guide

    Pre-installation (continued)

    Software requirements

    Windows XP Professional SP2/Windows 2003

    Server Standard SP1

    Internet Explorer 6.0 or better

    Tomcat 5.0

    JDK1.4.2

    Servlet 2.3

  • 7/28/2019 RTN 600 Configuration-A

    19/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 18Page 18

    T2000 Web LCT Installation Guide

    Prerequisite: Windows XP Professional SP2 or Windows 2003 Serverstandard SP1 must be installed.

    Procedure

    Step 1 Uncompress the installation package or Insert the installation CD,

    and run the setup.exe file. Click Next.

  • 7/28/2019 RTN 600 Configuration-A

    20/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 19Page 19

    T2000 Web LCT Installation Guide

    Step 2 Select I accept the terms of the license agreement and click Next.

  • 7/28/2019 RTN 600 Configuration-A

    21/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 20Page 20

    T2000 Web LCT Installation Guide

    Step 3 Enter your user name, company name, and serialnumber Click Next.

  • 7/28/2019 RTN 600 Configuration-A

    22/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 21Page 21

    T2000 Web LCT Installation Guide

    Step 4 Click Next.

  • 7/28/2019 RTN 600 Configuration-A

    23/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 22Page 22

    T2000 Web LCT Installation Guide

    Step 5 Click Install and the Setup Status dialog box is displayed. After theT2000 Web LCT is installed, the Installation Complete dialog box is displayed.

  • 7/28/2019 RTN 600 Configuration-A

    24/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 23Page 23

    T2000 Web LCT Installation Guide

    Step 6 Click Finish.

  • 7/28/2019 RTN 600 Configuration-A

    25/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 24Page 24

    T2000 Web LCT Installation Guide

    Checking the InstallationAfter you install the T2000 Web LCT, you need to check the

    correctness of installation. Check directories and files as follows:

    The T2000 Web LCT installation directory.

    By default is C:\Web_LCT.

    The installation directory of the jre software.

    By default is C:\Web_LCT\jre.

    The installation directory of the Tomcat software.

    By default is C:\Web_LCT\Tomcat .

    Check the shortcut icon on desktop. The iManager T2000 Web LCT group

    is created in the Windows Program bar.

  • 7/28/2019 RTN 600 Configuration-A

    26/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 25Page 25

    Contents

    Introduction to the T2000Web LCT

    2.1 Main Characteristics

    2.2 Application Scenario

    2.3 Installation Guide

    2.4 Connecting to NEs

    2.5 Configuration Operations

  • 7/28/2019 RTN 600 Configuration-A

    27/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 26Page 26

    T2000 Web LCT Connecting to NEs To use the T2000 Web LCT to configure and manage NEs, you need to

    connect the T2000 Web LCT to NEs with an Ethernet cable or a serial

    port.

    Procedure

    By using a network cable

    1. Connect a network cable to the computer where the T2000 Web

    LCT resides.

    2. Route the network cable to the equipment side and connect the

    RJ-45 connector of the network cable to the network

    management interface on the front panel of the equipment.

  • 7/28/2019 RTN 600 Configuration-A

    28/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 27Page 27

    T2000 Web LCT Connecting to NEs

    Procedure (continued)

    By using DCN

    1. Use a network cable to connect the computer where the T2000

    Web LCT resides to the DCN.

    2. Connect one end of another network cable to the network

    management interface on the front panel of the equipment.

    Connect another end to the DCN.

    By using an RS 232 serial port cable

    1. Connect the serial port cable to the computer where the T2000

    Web LCT resides.

    2. Route the serial port cable to the equipment side. Connect the RS

    232 connector of the serial port cable to the RS 232 interface on

    the front panel of the equipment.

  • 7/28/2019 RTN 600 Configuration-A

    29/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 28Page 28

    Contents

    Introduction to the T2000 Web

    LCT

    2.1 Main Characteristics

    2.2 Application Scenario

    2.3 Installation Guide

    2.4 Connecting to NEs

    2.5 Configuration Operations

  • 7/28/2019 RTN 600 Configuration-A

    30/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 29Page 29

    Contents

    Configuration Operations

    2.5.1 Logging In to an NE

    2.5.2 Modifying the NE ID

    2.5.3 Configuring IF Protection

    2.5.4 Setting IF Attributes

    2.5.5 Setting RF Attributes

    2.5.7 Configuring Service

    2.5.7 Configuring SNCP Service

    2.5.8 Converting service

    2.5.9 Alarm

    2.5.10 Performance

    2.5.11 Communications and Security

  • 7/28/2019 RTN 600 Configuration-A

    31/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 30Page 30

    Web LCT Configuration Logging In to an NE

    Step1 Double-click the T2000 Web LCT shortcut icon on the desktop to launch the

    T2000 Web LCT.

    Step2 The User Login screen is displayed. Enter the user name and password. Click

    Login.

  • 7/28/2019 RTN 600 Configuration-A

    32/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 31Page 31

    Web LCT Configuration Logging In to an NE

    Create an NE in one of the following two ways.

    1. Click NE Search and specify the search criteria. Select the NE to be added

    to create a new NE.

  • 7/28/2019 RTN 600 Configuration-A

    33/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 32Page 32

    Web LCT Configuration Logging In to an NE

    2. Create an NE directly. Click the Add NE and Enter the informationof the NE and create the NE.

  • 7/28/2019 RTN 600 Configuration-A

    34/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 33Page 33

    Web LCT Configuration Logging In to an NE

    Step 4: In the NE List, select the target NE and click NE Login.Then, the IE

    displays the NE Login dialog box.

    Step 5:Enter the User Name and the Password. Then, click OK.

  • 7/28/2019 RTN 600 Configuration-A

    35/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 34Page 34

    Web LCT Configuration Modifying the NE ID

    Step 1 In the NE Explorer, choose Configuration > NE Attribute from theFunction Tree. Click Modify NE ID.

  • 7/28/2019 RTN 600 Configuration-A

    36/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 35Page 35

    Web LCT Configuration Modifying the NE ID

    Step 2 Enter a new ID and click OK.

  • 7/28/2019 RTN 600 Configuration-A

    37/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 36Page 36

    Web LCT Configuration Modifying the NE ID

    Step 3 In the NE list, delete the original NE. Create a new NE with the newID.

  • 7/28/2019 RTN 600 Configuration-A

    38/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 37Page 37

    Web LCT Configuration Configuring IF Protection

    The supported IF protection is 1+1 HSB, 1+1 SD, and 1+1 FD.Create IF protection

    Step 1 In the NE Explorer, choose Configuration > IF 1+1 Protection

    from the Function Tree.

  • 7/28/2019 RTN 600 Configuration-A

    39/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 38Page 38

    Web LCT Configuration Configuring IF Protection

    Step 2 Click New and enter the information of the IF protection. Click OK orApply.

  • 7/28/2019 RTN 600 Configuration-A

    40/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 39Page 39

    Web LCT Configuration Configuring IF Protection

    Perform IF protection external switching. The priorities of externalswitching commands are as follows: clear, lockout, force, and manual.

  • 7/28/2019 RTN 600 Configuration-A

    41/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 40Page 40

    Web LCT Configuration Setting IF Attributes

    You can set the following IF attributes by using the T2000 Web LCT:

    working mode, link ID, IF port loopback, 2 Mbit/s wayside service, andATPC-related information.

    In the NE Explorer, select an IF board and choose IF Interface from the

    Function Tree.

  • 7/28/2019 RTN 600 Configuration-A

    42/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 41Page 41

    Web LCT Configuration Setting IF Attributes

    You can enable automatic transmit power control (ATPC), and adjust

    the threshold and the ATPC adjustment.

  • 7/28/2019 RTN 600 Configuration-A

    43/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 42Page 42

    Web LCT Configuration Setting RF Attributes

    By using the T2000 Web LCT, you can query and configure the following

    RF attributes: transmit frequency, T/R spacing, transmitted power, ODUmanufacturer information, RF loopback status, and ODU status.

    Frequency attributes

  • 7/28/2019 RTN 600 Configuration-A

    44/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 43Page 43

    Web LCT Configuration Setting RF Attributes

    Power attributes

  • 7/28/2019 RTN 600 Configuration-A

    45/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 44Page 44

    Web LCT Configuration Setting RF Attributes

    ODU manufacturer information

  • 7/28/2019 RTN 600 Configuration-A

    46/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 45Page 45

    Web LCT Configuration Setting RF Attributes

    In the Advanced Attributes tab, you set RF loopback and ODU status.

  • 7/28/2019 RTN 600 Configuration-A

    47/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 46Page 46

    Web LCT Configuration Configuring a Service

    This operation is applicable to VC4, VC3, and VC12 services.

    Procedure

    Step 1 In the NE Explorer, Configuration ->Cross-Connection

    Configuration from the Function Tree.

  • 7/28/2019 RTN 600 Configuration-A

    48/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 47Page 47

    Web LCT Configuration Configuring a Service

  • 7/28/2019 RTN 600 Configuration-A

    49/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 48Page 48

    Web LCT Configuration Configuring a Service

    Step 2 Click New, enter the information of a service and click OK orApply.

  • 7/28/2019 RTN 600 Configuration-A

    50/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 49Page 49

    Web LCT Configuration Configuring an SNCP Service

    This operation is applicable to VC12, VC3, and VC4 SNCP services.

    Procedure

    Step 1 In the Cross-Connection Configuration window, click Create SNCP.

    Enter the information of an SNCP service.

  • 7/28/2019 RTN 600 Configuration-A

    51/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 50Page 50

    Web LCT Configuration Configuring an SNCP Service

    Step 2 After you create an SNCP service, the window is divided into two

    panes. The upper pane displays the working service and the lower pane

    displays the protection service. You can perform external switching for the

    working and protection services.

  • 7/28/2019 RTN 600 Configuration-A

    52/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 51Page 51

    Web LCT Configuration Converting a Service

    The T2000 Web LCT supports the conversion between a normal service

    and an SNCP service.

    To convert a normal service to an SNCP service, select a normal

    service, right-click and choose Convert to SNCP from the shortcut

    menu. Enter the source of the service in the protection channel and

    click OK.

  • 7/28/2019 RTN 600 Configuration-A

    53/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 52Page 52

    Web LCT Configuration Converting a Service

    You can convert the working or protection channel of an SNCP service to a

    normal service.

    To convert a working channel, right-click the service in the working channel

    and choose SNCP Working Service Change to Normal Service from the

    shortcut menu.

  • 7/28/2019 RTN 600 Configuration-A

    54/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 53Page 53

    Web LCT Configuration Converting a Service

    To convert a protection channel, right-click the service in the protection channeland choose SNCP Protection Service Change to Normal Service from the

    shortcut menu.

  • 7/28/2019 RTN 600 Configuration-A

    55/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 54Page 54

    Web LCT Configuration Alarm

    By using the T2000 Web LCT, you can view the current and history

    alarms, the reporting status of alarms for an NE and boards, and

    abnormal events.

  • 7/28/2019 RTN 600 Configuration-A

    56/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 55Page 55

    Web LCT Configuration PerformanceThe T2000 Web LCT supports 15-minute and 24-hour performance

    monitoring intervals.

  • 7/28/2019 RTN 600 Configuration-A

    57/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 56Page 56

    You can view the current and history performance data, UAT events,threshold crossings, and performance monitoring status. You can set the

    performance threshold and reset a board registry.

    Web LCT Configuration Performance

  • 7/28/2019 RTN 600 Configuration-A

    58/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 57Page 57

    Web LCT Configuration Communications

    The RTN 600 uses the OSP NE platform.

    You can set multiple protocol stacks, including the OSI, IP, and

    HWECC.

    W b LCT C fi i C i i

  • 7/28/2019 RTN 600 Configuration-A

    59/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 58Page 58

    Web LCT Configuration Communications

    For DCC management, an IF board supports the configuration of

    different DCC rates in different working modes. When the working mode is PDH, the configuration of one-byte DCC

    (D1-D1) rate is supported.

    When the working mode is SDH, the configuration of D1-D3, D4-D12,

    D1-D12, and D1-D1 is supported.

  • 7/28/2019 RTN 600 Configuration-A

    60/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 59Page 59

    Contents

    1. Introduction to Management Systems

    2. Introduction to T2000 Web LCT

    3. Introduction to T2000

  • 7/28/2019 RTN 600 Configuration-A

    61/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 60Page 60

    Contents

    Introduction to T2000

    3.1 Main Characteristics

    3.2 Application Scenario

    3.3 Configuration Operations

  • 7/28/2019 RTN 600 Configuration-A

    62/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 61Page 61

    T2000 Main Characteristics

    The T2000 consists of server and client.

    The server is developed based on C++ and the client is based

    on Java.

    The T2000 manages a maximum of 1000 equivalent NEs and

    supports concurrent operations of 32 clients.

    T2000 server T2000 clientT2000 client

  • 7/28/2019 RTN 600 Configuration-A

    63/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 62Page 62

    T2000 Main Characteristics

    Modular architecture Open and integrated

    High efficiency and reliability

  • 7/28/2019 RTN 600 Configuration-A

    64/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 63Page 63

    Contents

    Introduction to T2000

    3.1 Main Characteristics

    3.2 Application Scenario

    3.3 Configuration Operations

  • 7/28/2019 RTN 600 Configuration-A

    65/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 64Page 64

    T2000 Application Scenario

    Subnet management system (SNMS)

    Applicable to small and medium network management

    Provides power NE management functions

    Uniformly manage the RTN/SDH/ASON/MSTP/WDM

    equipment

    Provides the standard northbound interfaces and supports

    OSS integration

    iManager T2000

  • 7/28/2019 RTN 600 Configuration-A

    66/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 65Page 65

    Contents

    Introduction to T2000 3.1 Main Characteristics

    3.2 Application Scenario

    3.3 Configuration Operations

  • 7/28/2019 RTN 600 Configuration-A

    67/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 66Page 66

    Contents

    Configuration Operations

    3.3.1 Microwave link

    3.3.2 Alarm

    3.3.3 Performance

    3.3. 4 Linear MSP

    T2000 Configuration Creating a Microwave

  • 7/28/2019 RTN 600 Configuration-A

    68/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 67Page 67

    T2000 Configuration Creating a Microwave

    Link

    The T2000 allows you to create a Microwave link. You can view the

    networking on the Main Topology.

    Step 1 On the Main Topology, right-click and choose Microwave link

    from the shortcut menu. Enter the information of the Microwave link.

    T2000 Configuration Creating a Microwave

  • 7/28/2019 RTN 600 Configuration-A

    69/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 68Page 68

    T2000 Configuration Creating a Microwave

    Link Alternatively, click the icon on the toolbar to display the Create Link

    window.

  • 7/28/2019 RTN 600 Configuration-A

    70/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 69Page 69

    T2000 Configuration Creating a Microwave Link

    Step 2 Click OK orApply. The link is displayed as follows:

    When the source and the sink have different working modes, the link status is abnormal.

  • 7/28/2019 RTN 600 Configuration-A

    71/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 70Page 70

    Current Alarm Statistics

    An NE reports current alarms to the T2000.

    You can filter alarms according to the report time of

    alarms.

    You can view alarm statistics in each NE.

  • 7/28/2019 RTN 600 Configuration-A

    72/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 71Page 71

    Customizing Alarm Attributes

    You can customize alarm functions, such as alarm severity, alarm

    suppression, and alarm reporting.

    The T2000 supports a maximum of 16 alarm templates.

  • 7/28/2019 RTN 600 Configuration-A

    73/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 72Page 72

    Alarm Correlation Analysis and Suppression

    A number of NE alarmsRoot alarm

    Alarm analysis rule

    Characteristics:

    Retain the root alarms.

    Suppress the non-root alarms. Customize the analysis rules.

    Suppress non-

    root alarms

    Customizing Performance Threshold

  • 7/28/2019 RTN 600 Configuration-A

    74/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 73Page 73

    Customizing Performance Threshold

    The T2000 supports customization of a maximum

    of 16 performance thresholds.

  • 7/28/2019 RTN 600 Configuration-A

    75/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 74Page 74

    History Performance Analysis

    The T2000 provides graphic history performance data analysis.

  • 7/28/2019 RTN 600 Configuration-A

    76/77

    Copyright 2006 Huawei Technologies Co., Ltd. All rights reserved. Page 75Page 75

    T2000 Configuration

    The T2000 and T2000 Web LCT are the same in terms of serviceconfiguration, IF protection, IF and RF attributes, and communications.

    Refer to the description in the T2000 Web LCT part.

  • 7/28/2019 RTN 600 Configuration-A

    77/77

    Thank youwww.huawei.com