32
The instruction for normal model with off-line control card KULLANICI EL KİTABI Aşındırma ve Kesim için Yazılım Sistemi

Software Manual 2

Embed Size (px)

DESCRIPTION

JG160100

Citation preview

Page 1: Software Manual 2

The instruction for normal model with off-line control card

Wuhan Golden Laser Equipments Manufacturing Co.,Ltd.

Add: GOLDEN LASER Building, NO.188 . BaiBuTing District,

Wuhan City,HuBei Province, P.R China.

Tel: 0086-27-82943848 Fax: 0086-27-82944068

Http: www.goldenlaser.cn E-mail: [email protected]

KULLANICI EL KİTABI

Aşındırma ve Kesim için Yazılım Sistemi

Page 2: Software Manual 2

www.goldenlaser.cn

CATALOGUE

Chapter 1. The menu for start and setup for button.................................................2

Chapter 2. Interface setup........................................................................................4

Chapter 3 Function Setup.........................................................................................7

Chapter 4 Format EMS memory............................................................................11

Chapter 5 System Information...............................................................................12

Chapter 6 The process of USB................................................................................12

Chapter 7 Process of transmit the date....................................................................16

Chapter 8. Alarm dialog box...................................................................................19

Chapter 9 Malfunction and examination.................................................................20

1

Page 3: Software Manual 2

www.goldenlaser.cn

Chapter 1. The menu for start and setup for

button

When the machine is on, there will appear Welcome Golden Laser. It is as below.

After 5 seconds, it will appear as below, if set the return home, the machine will appear as below.

When X.Y goes to home, the machine will appear “Idle” as below:

Explanation: It means the machine is idle, wait for the sign to next step operate.When the machine is idle, press “up”, “down”, “left”, “right” to move X and Y axis, it is as below:Press “Up” button.

2

Page 4: Software Manual 2

www.goldenlaser.cn

It indicates Y axis will move up direction.Press “Down” button.

It indicates Y axis will move down direction.Press “Left” button.

It indicates X axis will move left direction.

Press “Right” button.

It indicates X axis will move right direction.

3

Page 5: Software Manual 2

www.goldenlaser.cn

Chapter 2. Interface setup

Click the button of “Setup”, it will appear the picture as below:

Press “Down”, it will appear the second picture as below:

Press “Down” again, there will appear the third picture as below:

The first row: select the processing fileThe second row: delete the processing fileThe third row: process the file informationThe fourth row: setup for the systemic fileThe fifth row: formatting EMS memoryThe sixth row: system informationThe seventh row: save the position

4

Page 6: Software Manual 2

www.goldenlaser.cn

2.1 Select the processing fileAt first, move the cursor to the first row, click “right” button, then enter the processing file selection, as below:

Select the required processing file (The file which the cursor points is the selected one), then click “right” button for make sure, and click “delete” to return the idle display, click “start”, it will begin to process the selected one.

2.2 Delete the fileWhen you needn’t some processing files, or it already saved 10 files and can’t save others, please delete some files. The function is as below.Firstly, please move the cursor to the second row (delete file) for the setup menu, and then click “right” to select the files which you need to delete. It is as below:

Click the “right” button, then you can delete the pictures which you needn’t process.

2.3 Information for processing file.When you want to read the file, including the processing times and power or speed adjusting, please enter the processing file information to check the parameter, the function is as belowPlease move the cursor to the third row (processing information), click “right” to enter and it will appear the processing file in the card as below:

5

Page 7: Software Manual 2

www.goldenlaser.cn

Select the files needed to be check, and then click the “right” button, you will check it as the diagram:

The first row: Run time is the processing timeThe second row: Processing speedThe third row: Power adjustThe fourth row: Counter, time

2.4 System file setup When you need to setup the system file, please move the cursor to the fourth row (system setup), it is as below,

Click the “right” button to enter, in order to prevent the inaccurate function, please input the password. It is as below:

The password is: Up, down, left, right, start, stop, input this in turn to enter the system setup.After you enter the system setup, there three pages for the parameter. It is as below:

6

Page 8: Software Manual 2

www.goldenlaser.cn

The first row: laser adjust setupThe second row: go to home position setup.The third row: buzzer sound setupThe fourth row: setup for the systemic timeThe fifth row: setup for the motor typeThe sixth row: setup for working areaThe seventh row: setup for area limitationThe eighth row: laser setupThe ninth row: laser distance setup

Chapter 3 Function Setup

3.1 Laser current setup

7

Page 9: Software Manual 2

www.goldenlaser.cn

After enter system setup, please move the cursor to the first row of laser setup, enter “Right” button to enter, laser setup current is as below,

Select the current percentage, but it can’t too big. The reference value is 1%-2.8% according to the different laser tubes.

3.2 Return to home positionWhen cursor moved to the second row (Go to home setup) of the system setup, press “Right” to enter, it is as below:

When cursor moved to “Yes”, then press “setup” for confirmation, when start, X,Y axis will go to home automatically, if move to “No”, press “setup” for confirmation, X,Y axis will not go to home after start.

3.3 Buzzer sound setupMove the cursor to the third row (Buzzer sound setup) of system setup, and then press “Right” to enter, it is as below:

The setup for buzzer sound is from 0-9. Select the required sound times, and then clicks “setup” for confirmation. Then press “Exit” to the idle situation.

3.4 System time setupMove the cursor to the fourth row (system time setup) and then press “Right” to enter. It is as below:

8

Page 10: Software Manual 2

www.goldenlaser.cn

Setup the year, month, date and current time, after it, please press “setup” to confirm, press “exit” to return to the idle state, it is finished to modify the time.

3.5 Motor type setupMove the cursor to the fifth row (Motor type setup), and then press “Right” to enter, it is as below:

The first row: Step motorThe second row: Servo motor

If the X, Y axis is used with Step motor, please move the cursor to the first row, and then press “setup” for confirmation. If the X, Y axis is used with Servo motor, please move the cursor to the second row, and then press “setup” for confirmation. After the setup, please press “exit” to exit, it is finished by the motor type setup.

3.6 Setup the working area.Please move the cursor to the sixth row (working area setup), and then press “Right” to enter, it is as below:

If setup the working area of X, please move the cursor to X: 00800, (the initial state is X:

9

Page 11: Software Manual 2

www.goldenlaser.cn

00000), then press “Right” to enter, there will be occur the shining cursor, whose position can be adjusted the parameter through Up and Down. Press “Up” means add, press “Down” means decrease, after setup the parameter of X according to the working table size, press “exit” (It will be totally exit without saving if press two times). And then move the cursor to the Y: 00400, (the initial state is Y: 00000), press “Right” to enter, at this time, there will be shining cursor for the Y parameter. It is the same setup with X parameter setup. After the setup, press “exit” and move the cursor to Pitch: 032 (the initial state is 000), the setup mode is the same with X parameter setup. After total setup of X, Y, please press “Setup” for confirmation. At last, press “exit” to finish the total setup.

3.7 working area limitationPlease move the cursor to the seventh row (working area limitation), and the press “Right” to enter, it is as below:

“Yes” is adding the function of working area limitation, if select yes, it will alarm when exceeding the working area, if select no, it is no limitation for the working area.

3.8 Laser head setupWhen the cursor moved to the eighth row (Laser head setup), please click “Right” to enter, it is as below:

Alternative laser light: It means laser 1 and laser 2 will process to produce light by turns, it is used for double system laser machines.

Laser 1: The single laser machine will make one laser tube to produce light, it must be adjusted laser 1 produce light, or it will appear no light after a period of processing.Laser 2: It is laser 2 produce light, mainly used for double system of laser 2 to produce light by turns, if laser 1 has something wrong, it can be selected laser 2 for processing.

10

Page 12: Software Manual 2

www.goldenlaser.cn

3.9 Laser distancePlease move the cursor to the ninth row (laser distance), it is as below:

When the machine produces light by turns, it means the distance between the light produced from laser 1 and laser 2. The setting method: Please firstly move the cursor to the position of X, and then press “right” to adjust the X parameter, press “test” button, it can test whether the two laser heads light point will be superposition, when it is superposition, please press “setup” to confirm for saving it. In the models of double system, it will produce light by turns to process. The reference value is 48.5mm.

Chapter 4 Format EMS memory

We suggest USB format, if there is some confusion of system, machining abnormity,move

cursor to format EMS memory, and press“Right” button to enter. It is as below:

Move cursor to Y,and press “Setup” to confirm, The EMS memory can be format if we do

it like this.

11

Page 13: Software Manual 2

www.goldenlaser.cn

Chapter 5 System Information

Move cursor to system information, and then press the right button to enter,it is as below:

And press the right button to enter as follows

Edition information is the number of edition on display control card.

Chapter 6 The process of USB

6.1 Return to home, if you can’t setup the machine return to home, please do it like

that firstly, otherwise it will broken the machine.The machine will return to the home if you press the home button when the machine stops as follows

6.2 Guide the picture,and put into the U disk,it will appear as follows:

12

Page 14: Software Manual 2

www.goldenlaser.cn

Choose the document which you need to process,and press the“Right”button to confirm

It will appear the dialog box, if there is a picture have the same name as follows:

Note: Cover with the original picture“Yes” or“No”?If “Yes”, press “Right”button to

confirm,so the picture will covered with another picture which in the U disk.

6.3 Setup scope

Press the setup button to enter into the setup menu,and move the cursor to the sixth(Work

area)press “Right”button and enter into it, and input the password and enter into the setup

interface(work area),set up the parameter of X,Y and so on after enter into the setup.

Please press the button “Setup” to confirm.(No need to operate this step if the picture is

ok.).

6.4 Process the picture

Make sure the location of material by draw frame as follows:

13

Page 15: Software Manual 2

www.goldenlaser.cn

6.5 Press the button of start to process the picture, it will appear the following picture

when processing:

6.6 Please press the button of Pause on the Control panel if you want to stop a while

during moving as follows:

6.7 Please press the button of Stop on the control panel if you want to stop during

wroking as follows:

6.8 If you find some situation like the power too large, or the speed too quick, or the

equipment stop to work,Please adjust the coder button by yourself to control the

speed and power in the “I die” condition, it will make the quality better. It will

14

Page 16: Software Manual 2

www.goldenlaser.cn

appear the following picture when you adjust the speed:

It will appear the following picture when you adjust the power:

6.9 You can keep the same location if you want to do the same picture next time after

machining as follows:

Chapter 7 Process of transmit the date

7.1 Introduction of function

15

Editor Toolbar Standard Toolbar Display Toolbar Control Panel

Page 17: Software Manual 2

www.goldenlaser.cn

There are eight parts when you open the Golden Laser USB control software as follows:

Editor Toolbar, Standard Toolbar, Display Toolbar, Control Panel, The area of editor picture, Establish Toolbar, Picture Toolbar, Status Bar.

7.2 Guide or open the machining document

Dot or button on the software, guide or open the picture of machining panel, please check the introduction of USB card software if you need to set up, typeset.

16

Picture ToolbarEstablish Toolbar

The area of editor picture

Status Bar

Page 18: Software Manual 2

www.goldenlaser.cn

7.3 Setting of machining pictureIt will appear the following dialog box when you double dot the picture on the control panel:

.

Length of overlap in seal: It will appear the location in seal can’t overlap when you machining the

picture,you can repair the length of overlap if you setting this parameter.

Power of machining:The laser power when you machining with quick speed.

Lowest speed:The laser power when you machining with slow speed.

Speed of machining:The speed of machining the date of picture.

Acceleration of machining: It means from the starting speed to machining speed when machine is working. If you set the system parameter with automatic, so the parameter can’t be amend. But you can

amend it if you set it by hand.

17

Page 19: Software Manual 2

www.goldenlaser.cn

Space between of BMP engrave: Scan space between when you scan the BMP,and this function only can be setting when you machining BMP.

Power of BMP machining:The laser power when you machining BMP, and this function only can be setting when you machining BMP.

Space of Filling:Please fill the space of line when you fill the picture.

Draw frame:If you press this button, it will draw the picture out of frame when filling, otherwise not.

Filling Angle:Fill the picture of vector, please fill the angle. Holistic filling:You need to choose the way to fill, one the holistic filling, another is aliquot filling.

Filling:Please dot this button after setting the parameter of filling.

Time of machining:This layer need to setting time of machining.

Input YES or No:Do you need to machining,YES or No.

7.4 Process of picturePlease dot the button of machining date after setting of parameter, , the date will arrive to machine through USB port, and there are two documents as follows:

You can define the name of document by yourself after download, or pretermit. The display toolbal of information show the speed to download It will appear after finished. Please dot the key of frame to make sure the location of material, and dot the START to machining.

7.5 Repeated machining

Down load Create Data

18

Page 20: Software Manual 2

www.goldenlaser.cn

The data will saved by USB card. You only need to take the date out of the USB card to machining if you want to do the same picture. No need to download by computer.

Chapter 8. Alarm dialog box

8.1 Alarm of excess working scope;

8.2 The document has existed. Cover YES or No?

8.3 Out of the date

8.4 Errors to open the document

19

Page 21: Software Manual 2

www.goldenlaser.cn

8.5 No processing file

8.6 Alarm of use term

When your machine is expired please contact with us and reference the how to update amnual.

20

Page 22: Software Manual 2

www.goldenlaser.cn

Chapter 9 Malfunction and examination

Malfunction Examination

HitWithout back to the home , open the

machine, and turn to the home.Hit No limit of working scope, please setting

No laser after some machining time Setting laser tube to work alternant

There is some abnormity when machining Confused of system, please format EMS memory

Excess the working scope Please turn back to the origin and setting the working scope and distance in correct.

Out of the date Please login again otherwise can’t use it.

Errors to open the document or no document No date in control card

21