User’s Manual GB GB/TSF/UM-0607-2 1 (11)

Citation preview

Page 1: TSF Users Manual (GB) 06072.indd MACHINE ENVIRONNEMENT

1 (11)

GB/TSF/UM-0607-2

User’s Manual

Dust fi lter TSFDust fi lter TSF

GB

Page 2: TSF Users Manual (GB) 06072.indd MACHINE ENVIRONNEMENT

2 (11)

GB/TSF/UM-0607-2

GB

An Absolutely Clean Industrial Environment

Absolent dust fi lters provide a unique and fl exible functional solution for your applica-tion. Their design offers unique fi lter charac-teristics and enables long intervals between servicing. The exceedingly high collecting effi ciency of the fi lter spares the personnel, premises and machinery exposure to annoy-ing dust and other impurities. This provides economic benefi ts and gives the employees a better working environment.

In the following instructions for use, you’ll fi nd all information you need for starting and operating the unit and for its maintenance. Never hesitate to contact Absolent or any of our retail sales outlets should you need technical support or service.

User’s Manual - Dust fi lter TSF

Contents:

Range of Application ................................3Performance/Design .................................3Installation ................................................4Fault Tracing .............................................4Operation/Maintenance ...................... 5 - 6 Filter Replacement & Cleaning the fi lter cartridges

TSF Technical Data .............................. 7-8 Safety Precautions ............................... 8-9Service .....................................................9EG Compliance ........................................9Electrical Connections ....................10 – 11 Wiring Diagram Adjusting the Sequencer

Rights reserved for modifi cations in design and measurements.

Page 3: TSF Users Manual (GB) 06072.indd MACHINE ENVIRONNEMENT

3 (11)

GB/TSF/UM-0607-2

GB Range of Application

4

2

1

1010

7

3

GB5

68

TSF4F

TSF4-1200 & TSF8-1200The dust-laden air is sucked into the inlet (1) at the top of the fi lter and fl ows downward. When the air enters the fi lter chamber, its velocity drops and the heaviest particles in the dust fall into the dust container (4) before the air and the lighter particles fl ow further through the fi lter cartridges (2) where the dust collects. The fi ltered air then sucked out through the fi lter outlet 3) in the top of the fi lter unit by the external fan.

2

1 TSF8-1200

4

2

TSF4-12001

2

4

13

Rights reserved for modifi cations in design and measurements.

The TSF fi ltration unit is solely designed for cleaning dry air polluted with dust. The use of this type of fi lter in other applications is not permissible unless the manufacturer has guaranteed that it will operate correctly in that environment. If the TSF is used in environments where the air can contain graphite, lead or chrome, it may be necessary to clean the fi lter unit and replace its fi lter cartridges more frequently.

Warning! The TSF must not be connected to machines whose machining operations involve a risk of explosion or to media that are infl ammable and where there is risk of dust explosions; without fi rst obtaining approval from Absolent.

Performance / Design – TSF4F & TSF4/8-1200TSF4FThe dust-laden air is sucked into the inlet (1) on the side of the fi lter. When the air enters the fi lter chamber, its velocity drops and the heaviest dust particles fall into the dust container (10). The air and lighter particles fl ow further through the four fi lter cartridges (2) where the dust collects. The clean air then fl ows to the integrated fan (4), which discharges the air across an absolute fi lter (3) to outlet (5). At this point, the air is so clean that it can be returned directly to the room. When-ever the pressure drop across the fi lter cartridges (2) exceeds the preset limit value, the valves in the pulse-cleaning air tank (7) are activated and discharge a pulse of compressed air (approx. 4 Bar) from cleaning nozzles (8) (1 nozzle/fi lter cartridge). This reverses the air in the fi lter cartridges (2). The compressed-air pulse jars the dust collected on the surface of the fi lter medium causing it to fall down into the dust container (10).

1. Inlet2. Filter cartridges 2. Filter cartridges 3. Absolute fi lter4. Fan5. Outlet 6. Manometers7. Air tank for cleaning8. Cleaning nozzle 8. Cleaning nozzle 9. Control cubicle 9. Control cubicle - cleaning10. Dust container10. Dust container

9

Whenever the pressure drop across the fi lter cartridges (2) exceeds the preset limit value, cleaning starts (see the TSF4F explanatory sketch) by activating valves for cleaning which discharge compressed air (approx. 4 Bar) from cleaning nozzles (1 nozzle/fi lter cartridge). This reverses the air in the fi lter cartridges (2). The compressed-air pulse jars the dust collected on the surface of the fi lter medium causing it to fall down into the dust container (4)

Page 4: TSF Users Manual (GB) 06072.indd MACHINE ENVIRONNEMENT

4 (11)

GB/TSF/UM-0607-2

GB Installation

A

GB Fault Tracing

Rights reserved for modifi cations in design and measurements.

1. Check that the fi lter unit has not been damaged in the transport. If it is damaged in any way, get in touch with the haulage contractor.2. Transport the fi lter to its fi nal location, which should be horisontal and plane. The fi lter unit has a high centre of gravity. Secure the fi lter properly while transporting it or transport the fi lter lying in the horizontal position. Use the lifting lugs on the upper side (TSF4F and TSF8) for the lifting bracket by the inlet of the fi lter (TSF4-1200 and TSF8-1200) for lifting the fi lter or raising it from a horizontal position. An upright fi lter can also be lifted and transported by means of a forklift truck provided that the dust container has been dismantled and the forks are applied against the surface where the container is normally fastened to the fi lter. Be careful not to damage the compressor tank and other components on the underside of the fi lter. Caution! Forklift truck lifting is rather unstable; involves a high risk of the unit tipping over. 3. Open the inspection cover and check that the fi lter cartridges are secured in their appropriate position. If they have become loose during transport, fasten them and close the cover. 4. Connect the suction duct with control damper (no control damper is needed if the fan is equipped with frequency control). If any duct branches are to be connected, it is advisable to connect them as illustrated in A, since arrangement enables a lower pressure drop and lessens the risk of dust collecting at the joint. 5. Connect the power supply as shown in the wiring diagram (see the section entitled ”Electrical Connections”, etc.).6. Connect clean and dry compressed air to the header tank (4 bar).7. Start the fan, check that its impeller rotates in the right direction as shown by the arrow on fan casing (see under ”Electrical Connections as well) and set the appropriate airfl ow by means of the control damper or speed control unit, if installed. If the airfl ow is insuffi cient, this may be because the fan impeller is rotating in the wrong direction.8. If Absolent has recommended a pre-coating of the fi lter cartridges, this has to be carried out before the fi lter is to be in operation. The pre-coating powder is sucked into the unit via the supply air duct (0,125 kg/600 cartridge, 0,25 kg/ 1200 cartridge, see also sequencer settings

Pressure drop across new fi lter media: • On a normal airfl ow through clean TSF fi lter cartridges, the pressure drop across the fi lter cartridges is about 100-300 Pa. A lower air fl ow could mean that there is a leakage.

Preventive maintenance and regular service will lengthen the useful life of your installation. This will also enable maintaining consistent, high cleaning performance in the industrial environment.

Fault TracingIf the dust collecting capacity is low:• Check that the fan impeller rotates in the correct direction • Check the speed of the fan if it is speed controlled• Check the pressure drop across the fi lter. Higher than 2500 Pa and/or alarm signal from the sequencer• Check that any damper fi tted on suction duct between the machine and the fi lter unit is correctly set • Check the suction duct between the machine and the fi lter unit for leakage• Check that the duct system isn’t clogged

If the interval between fi lter changes in absolute fi lters is short (TSF4F) and/or if the fi lter isn’t fi ltering properly:• Check that the fi lter cartridges are intact. The fi lter material may be damaged due to careless handling. • Check that the fi lter cartridges have been correctly mounted and properly secured. • Check that the sealing strips of the fi lter cartridges aren’t damaged. • Check that the manometer is working properly (0 Pa when fan is shut down).

If the interval for servicing the fi lter cartridges is abnormally short: • Check that the compressed air cleaning mechanism is operating properly (see separate instructions for

electronically controlled pulse-cleaning system). • Check that the airfl ow conforms to sizing specifi cation for the system. Too high an airfl ow impairs the

cleaning function and shortens the useful life of the fi lter cartridges as well. • Check that the manometer is working properly (0 Pa when fan is shut down).

Service intervalIf the airfl ow is too low or if the pressure drop across the fi lters exceeds the in-service level (standard: 2500 Pa /alarm level), it is time to change or clean the fi lters. Filters should be cleaned or replaced when the pressure drop has reached the alarm level of the sequencer. The length of the service intervals varies between different applications. How to handle the fi lter medium while servicing the unit is described under the heading ”Replacing and Cleaning the Filter Cartridges”.

Page 5: TSF Users Manual (GB) 06072.indd MACHINE ENVIRONNEMENT

5 (11)

GB/TSF/UM-0607-2

GB Operation / Maintenance

A

A

B

AAAA

Fig.a Fig.b

Replacing and Cleaning the Filter CartridgesInstructions1. Shut down the fan by opening the safety-isolating switch to isolate the power supply 2. Switch off the power to the automated pulse-cleaning system. 3. Open the inspection cover. 4. The fi lter cartridges and the fi lter chamber should be preliminarily cleaned by brushing and blowing the dust down into the dust container. Use a soft brush and a compressed air nozzle for this purpose. A way of preventing dust from escaping into the premises is to open and secure the inspection this open position; and then start the fan. Caution! Wear protective glasses and ear protection while doing this work. 5. Release the fi lter cartridges by backing off their quick-action annular fastener as described in separate instructions. Slip a plastic bag over the each fi lter cartridge before dismantling it to prevent dust from spilling on the outside the fi lter chamber. 6. Loosen the hoses to the manometers and the sequencer and blow them clean. Check that the manometers indicate 0 Pa. 6. The cartridges fi lters are washable up to three times. The simplest ways to wash them is spraying them with a high-pressure jet, fl ushing them with a water hose or spraying them in a chamber. Max. temp. 100°C, 5–7 pH. It is important to fi nd out if the dust collected in the fi lter contains environmentally dangerous substances so that they can be disposed of in accordance with local regulations. After it has been washed, the fi lter should dry by itself (approx. 1 week in room temperature). The absolute fi lter is not washable. It must be replaced when the pressure drop exceeds the max. permissible in-service level (600 Pa).6. Before fi tting the fi lter, check that its sealing strip isn’t damaged. The sealing strip on the absolute fi lter (TSF4F) should be seated upward. 7. Fit the fi lters according to separate instructions and close the inspection cover. 8. Start the fan and check the pressure drop. If the pressure drop across the fi lter cartridges is below 100 Pa at the rated air- fl ow, check that the fi lter cartridges are properly fastened and that no other leakage has arisen. If the pressure drop exceeds 1200 Pa and washed fi lters have been fi tted, it is time to replace them or wash them in another way (get in touch with Absolent for advice). If the fi lter cartridges should be pre-coated, this has to be carried out before the unit is started. (See also ”Installation”, item 8).

Sketch 1: Fitting and removing the fi lter cartridges of the TSF4FSketch 1: Fitting and removing the fi lter cartridges of the TSF4FThe TSF4F has one fi lter fastener per fi lter cartridge, which consists of a clamping ring (A) with three bevelled dogs (AA), which is slipped over the fi lter cartridge (Fig. a). Each dog is positioned with its opening against one of fi lter cartridge (Fig. a). Each dog is positioned with its opening against one of three tension bolts (Fig. b). To secure the fi lter cartridge, turn the clamping ring and let the tension bolts (B) slide against the bevelled surface of the clamping ring. Removing the fi lter cartridges 1. After you’ve brushed off or blown the fi lter cartridge clean (don’t forget to clean the top of each fi lter cartridge) release the fi lter cartridges by turning the clamping ring (A) counter clock- wise (left-hand fi lter cartridges) or clockwise (right-hand fi lter cartridges).2. Pull the clamp rings (A) over the fi lter cartridges, clean them and put them aside. Caution! Some are of right-hand and others are of left-hand design.3. When you’ve freed the fi lter cartridges, slip a plastic bag over them to avoid spilling dust outside the fi lter. 4. When you take the fi lter cartridges out of the fi lter chamber, lift up each cartridge, tip it inward and lift it out bottom end fi rst. Be careful so that the tension bolts won’t damage the gasket of the fi lter cartridges.Fitting the fi lter cartridges Fitting the fi lter cartridges 1. If new cartridges are to be fi tted, remove the support cage and the fi lter insert from the old cartridges by backing off the nut on the topside of the cartridge. 2. Wipe clean or vacuum-clean any dust that has fallen down into the air duct and landed on the sealing surface of the fi lter cartridges before fi tting them. 3. Lift the fi lter cartridges into the fi lter chamber with the upper section fi rst and place each on the appropriate air duct. 4. Slip the clamping rings (A) over the fi lter cartridges and fi t them against the tension bolts (B). Caution! Some are of right- hand and others are of left-hand design. 5. Secure the fi lter cartridges by turning the clamping rings clockwise (left-hand fi lter cartridges) or counter clockwise (right-hand fi lter cartridges) until the tension bolts reach the bottom in the groove (AA).6. Check that the fi lter cartridges are securely fastened, if not, the tension bolts will have to be adjusted.

Rights reserved for modifi cations in design and measurements.

Page 6: TSF Users Manual (GB) 06072.indd MACHINE ENVIRONNEMENT

6 (11)

GB/TSF/UM-0607-2

A

B

C

D

F

E

Sketch 1: Removing and fi tting the fi lter cartridges, TSF4-1200 / TSF8-1200

The TSF4-1200 and TSF 8-1200 has one fi lter fastener for every 2 fi lter cartridges. They are located inside the fi lter chamber above the inspection cover. The fi lter fasteners consist of a clamping arm (B), leaf spring (C), pressure plate (D), clamping dog (E) and service dog (F).

Removing the fi lter cartridges Removing the fi lter cartridges 1. After the cartridge has been brushed or blown clean (don’t forget to clean the upper side of the fi lter cartridges) release the clamping lever (B) by pulling it downward and pressing it slightly inward to free it from the clamping dog (E). 2. So that the clamping device won’t be in the way while the you service the unit, lift up the clamping lever and hook it up in the service dog (F).3. Once the fi lter cartridges have been freed, slip a plastic bag over them to avoid spilling dust outside the fi lter.4. When you take the fi lter cartridges out of the fi lter chamber, lift up each cartridge, tip it inward and lift it out bottom end fi rst. Be careful so that the tension bolts won’t damage the gasket of the fi lter cartridges.

Fitting the fi lter cartridges Fitting the fi lter cartridges 1. If new cartridges are to be fi tted, remove the fi lter insert from the old cartridges by backing off the nut on the topside of the cartridge. 2. Wipe clean or vacuum-clean any dust that has fallen down into the air duct and landed on the sealing surface of the fi lter cartridges before fi tting the fi lter cartridges. 3. Lift the fi lter cartridges into the fi lter chamber with the upper section fi rst and place each on the appropriate air duct.4. Release the clamping device from the service dog (F) and sink the fi lter cartridges. At the same time, check that the pressure plate is centred over the fi lter cartridge. 5. Secure the fi lter cartridges by pulling the clamping levers downward and hooking them in the clamping dog. The clamping force of the clamping lever should be 20 – 25 kg. 6. Check that the cartridges are properly secured. If not, adjust the clamping dog (E).

Draining and inspection of header tankDrain the header tank daily from condense water, by opening the drain nipple situated on the tank. To control internal rust, the header tank should be inspected once a year, this is done by fi rst emptying the tank from comressed air, dismounting the inspection lid and then measuring the thickness of the tank.The thickness should not be less than 2mm.

Rights reserved for modifi cations in design and measurements.

Page 7: TSF Users Manual (GB) 06072.indd MACHINE ENVIRONNEMENT

7 (11)

GB/TSF/UM-0607-2

Technical Data TSF-4FMax. permissible air fl ow 25001) m³/h

Filter area (cartridge fi lter) 312) m²

Filter area (HEPA fi lter) 24 m²

Number of fi lter cartridges 4 pcs.compressed air consumed 20-1003) l/min (compressed air-pulse cleaning)

Pressure in cleaning tank 4 Bar

Sound level4), operation/cleaning 60/85 dB(A)

Voltage Fan 400V 3-ph.

Sequensor 220V 1-ph.

Current Fan 4,0 kW

Sequensor 30 WWeight 600 kgCompressed air connection 1/4 NPTF

GB Technical Data TSF

Absolent

TSF4-1200

Max. permissible air fl ow 2500

Filter area (cartridge fi lter) 31

Filter area (HEPA fi lter) 24 m²

Number of fi lter cartridges 4 pcs.compressed air consumed 20-100

Pressure in cleaning tank 4 Bar

, operation/cleaning 60/85 dB(A)

Voltage Fan 400V 3-ph.

Sequensor 220V 1-ph.

Current Fan 4,0 kW

Sequensor 30 WWeight 600 kgCompressed air connection 1/4 NPTF

TSF4F

Technical Data TSF4-1200Max. permissible air fl ow 69001) m³/h

Filter area (cartridge fi lter) 622) m²

Antal fi lter cartridges 4 pcscompressed air consumed 40-2003) l/min (compressed air-pulse cleaning)Pressure in cleaning air tank 4 Bar Sound level4), operation/cleaning 50/80 dB(A)Voltage Sequensor 220V 1-ph.Current Sequensor 30 WWeight 700 kg

Compressed air connection 1/4 NPTF

Antal fi lter cartridges 4 pcsAntal fi lter cartridges 4 pcs

Pressure in cleaning air tank 4 Bar Pressure in cleaning air tank 4 Bar , operation/cleaning 50/80 dB(A), operation/cleaning 50/80 dB(A)

Sequensor 220V 1-ph. Sequensor 220V 1-ph.

Max. permissible air fl ow 6900

Filter area (cartridge fi lter) 62

Antal fi lter cartridges 4 pcscompressed air consumed 40-200

Pressure in cleaning air tank 4 Bar

Antal fi lter cartridges 4 pcs

, operation/cleaning 50/80 dB(A)

Sequensor 220V 1-ph.

Pressure in cleaning air tank 4 Bar , operation/cleaning 50/80 dB(A)

Sequensor 30 WWeight 700 kg

Compressed air connection 1/4 NPTF

Sequensor 220V 1-ph.

Sequensor 30 W Sequensor 30 W Sequensor 30 W

Rights reserved for modifi cations in design and measurements.

1) The max. permissible airfl ow rate depends the type of dust that is to be fi ltered.2) Can be increased up to 80 m2.3) The volume of compressed air consumed depends on how often the fi lter needs to be cleaned. This depends on how heavily the fi lter is loaded with dust. The compres- sor and air tubing should be sized for 200 l/min consumed during the cleaning cycle.4) Approximate sound level measured 1 m from the fi lter in a normal room. The higher fi gure has been measured during a clean- ing pulse. Get in touch with Absolent for assistance with sound calculations.

1) The max. permissible airfl ow rate depends on the type of dust that is to be fi ltered.2) Can be increased up to 40 m2.3) The volume of compressed air consumed depends on how often the fi lter needs to be cleaned. This depends on how heavily the fi lter is loaded with dust. The compressor and air tubing should be sized for 100 l/min consum- ed during the cleaning cycle. 4) Approximate sound level measured 1m from the fi lter in a normal room. The higher fi gure has been measured during a cleaning pulse. Get in touch with Absolent for assistance with sound calculations.

Absolent

Page 8: TSF Users Manual (GB) 06072.indd MACHINE ENVIRONNEMENT

8 (11)

GB/TSF/UM-0607-2

Tekniska data TSF8-1200Max permissible air fl ow 138001) m³/hFilter area (cartridge fi lter) 1242) m²Number of fi lter cartridges 8 pcs.Compressed air consumed 40-2003) l/min (compressed-air pulse cleaning)

Pressure in cleaning tank 4 Bar Sound level4), operation/cleaning 50/80 dB(A)Voltage Sequensor 220V 1-ph.Current Sequensor 30 WWeight 950 kgCompressed air connection 1/4 NPTF

GB Technical Data TSF

TSF8-1200

Max permissible air fl ow 13800 124

Number of fi lter cartridges 8 pcs.Compressed air consumed 40-200

Pressure in cleaning tank 4 Bar 50/80 dB(A)

Sequensor 220V 1-ph.

Sequensor 30 WWeight 950 kgCompressed air connection 1/4 NPTF

Rights reserved for modifi cations in design and measurements.

1) The max. permissible airfl ow rate depends on the type of dust that is to be fi ltered. 2) Can be increased up to 160 m2.3) The volume of compressed air consumed depends on how often the fi lter needs to be cleaned. This depends on how heavily the fi lter is loaded with dust. The compressor and air tubing should be sized for 200 l/min consumed during the cleaning cycle. 4) Approximate sound level measured 1 metre from the fi lter in a normal room. The higher fi gure has been measured during a cleaning pulse. Get in touch with Absolent for assistance with sound calculations.

GB Safety precautions

Caution!Do not put your hand inside the fi lter cabinet while the fan is operating (TSF4F).

Caution!Always check the weight of the unit before you lift it.The fi lter unit has a relatively high centre of gravity due to the location of its fan (TSF4F) and the length of its legs.Whenever you transport and lift the fi lter, secure it in an appropriate manner, or transport the unit lying in the horizontal position.For mounting the fi lter unit, use the hook that is fastened on top of the unit. Check that all connections are securely fastened before lifting. Demount the lifting hook and the leg support after placing the unit at its fi nal place.

AbsolentAbsolent

AbsolentAbsolent

Page 9: TSF Users Manual (GB) 06072.indd MACHINE ENVIRONNEMENT

9 (11)

GB/TSF/UM-0607-2

GB Safety precautions

GB EC Compliance

GB Service

Explosion risk!- TSF4F is never to be used with explosives inside, because the built-in fan does not fulfi ll the

requirements for explosion safety. There is a risk for electrostatic discharge in the fi lter chamber. TSF4F is never to be used in explosive surroundings, because the starter, sequencer and magnetic

valves do not fulfi ll the requirements for explosion safety. - TSF4-1200 and TSF8-1200 are never to be used with explosives inside, because there is a risk for

electrostatic discharge in the fi lter chamber. TSF4-1200 and TSF8-1200 are never to be used in explosive surroundings, because the starter,

sequencer and magnetic valves do not fulfi ll the requirements for explosion safety. - TSF4-1200E and TSF8-1200E can be used with explosives inside, because all parts of the fi lter unit are

earthed and the fi lter cartridges are anti-static, which eliminates the risk for electrostatic discharge in the fi lter chamber.

TSF4-1200E and TSF8-1200E are never to be used in explosive surroundings, because the starter, sequencer and magnetic valves do not fulfi ll the requirements for explosion safety.

Please contact Absolent for further information.

Other PrecautionsIsolate the power supply to the fi lter/fan before you open the fi lter and/or begin working with the fi lter/fan. Don’t wear loose-fi tting clothes near a fan that is running or near rotating shafts. Loose-fi tting clothes can be sucked into the fan or get caught on moving parts. Keep the area around the fi lter clean so that staff won’t slip and injure themselves. If the sound level at the control panel/workplace exceeds 75 dB(A), wear ear protection.

Absolent hereby certifi es that the TSF-4F Dust Filter is manufactured in accordance with:• The Machinery Directive: 98/37/EC• The EMC Directive: 89/336/EEC together with Appendix 93/31/EEC and 93/68/EEG• The LVD Directive: 73/23/EEC together with Appendix 92/68/EEC• The Directive of Simple Pressure Vessels: 87/404/EEC

Absolent hereby certifi es that the TSF4-1200 and TSF8-1200 Dust Filter is manufactured in accordance with:• The EMC Directive: 89/336/EEC together with Appendix 93/31/EEC and 93/68/EEG• The LVD Directive: 73/23/EEC together with Appendix 92/68/EEC• The Directive of Simple Pressure Vessels: 87/404/EEC

Absolent offers you a complete range of spare parts and full service. This ensures reliable performance in your installation. For questions concerning maintenance and spare parts, contact:

Main offi ceAbsolent AB Kartåsgatan 1SE-531 40 Lidköping SwedenPhone: +46 510-48 40 00Fax: +46 510-48 40 29E-mail: [email protected]

Rights reserved for modifi cations in design and measurements.

Local dealer

Page 10: TSF Users Manual (GB) 06072.indd MACHINE ENVIRONNEMENT

10 (11)

GB/TSF/UM-0607-2

GB Electrical connections and Adjustment

GeneralThe Absolent TSF Dust fi lter is standard-equipped with a so-called sequencer that electronically controls the automated pulse-cleaning system that cleans the fi lter cartridges. The sequencer consists of a microprocessor and a differential pressure sensor. The differential pressure sensor continually measures the pressure drop across the fi lter cartridges (the reading can be viewed on the display). The cleaning process starts either when the pressure drop across the cartridges exceeds the preset value (pressure-controlled cleaning) or at uniform time intervals (0 – 999 sec.) (fi xed time-controlled cleaning).

For the warrantee to apply, a qualifi ed person must carry out all the electrical wiring in accordance with local regulations.If the fi lter unit is equipped with extra electrical equipment, this equipment shall be wired according to the wiring diagram supplied with the fi lter unit.

Inspection the fi rst time the unit is startedMake sure that the fan impeller rotates in the correct direction indicated by an arrow on the fan casing/motor. If you cannot see the motor while the fan impeller is rotating, start the fan, read the pressure drop across the fi lters from the manometer, stop the fan, transpose two phase leads, restart the fan and read the pressure drop again. The connection that gave the highest pressure drop is the correct one.

Wiring the fan (TSF-4F)The fan must be wired according to the wiring diagram below.

Rights reserved for modifi cations in design and measurements.

Operation with remote control remove jumper 2-3.Connection to external alarm 6-7

To motor

Page 11: TSF Users Manual (GB) 06072.indd MACHINE ENVIRONNEMENT

11 (11)

GB/TSF/UM-0607-2

GB Sequencer: Wiring and SettingsSRL Turbo Sequencer (standard)WiringWiringOn delivery, the cleaning valves (24 V DC) are factory-wired and the pressure hose is connected to the sequencer. When you install the fi lter unit, you’ll have to wire the power supply cable to the sequencer, 230 V AC, 50 Hz (<50 W).We at Absolent recommend that you wire the power supply across a safety-isolating switch.

Particulars of the Settings: (Press the arrow pointing right, to reach line 1)1. Pressure-controlled cleaning = 0, Time-controlled cleaning = 1, (see general explanation). Std. = 02. Pulse duration: 2-500 ms. The time needed for cleaning each cartrige, Std. =200 ms3. Pause duration: 1-250 s. The pause time between the cleaning of each cartridge, Std. = 20 s.4. Min. permissible differential pressure. The cleaning process is switched off when the differential pressure

across the cartridges falls below the preset value (pressure-controlled cleaning) Std. =1,3 kPa.5. Max. permissible differential pressure. The cleaning process starts when the differential pressure across the

cartridges exceeds the preset value (pressure-controlled cleaning) Std. =1,8 kPa.6. Alarm level. Adjustable level when the sequencer shall initiate an alarm for an excessively high pressure

drop across the fi lter cartridges. Std. = 2,5 kPa.7. Number of ducts (cleaning valves) used (1 – 8 valves), Std. = 4 pcs. (TSF-4F & TSF4-1200) / 8 pcs. (TSF8-1200).8. Number of subsequent cleaning cycles 0 – 99 pcs. Std. = 4 pcs. A preset number of subsequent cleaning cycles

are started when the sequencer measures a differential pressure lower than the preset value set in line 11 (i.e. fi lter not in operation), One cleaning cycle implies that all cartridges are cleaned once (four cleaning cycles = all cartridges are cleaned four times).

9. The valve outputs can be manually activated. Press ”+” to choose valve, press ”-” to activate.10. You can reset the differential pressure gauge to zero while you adjust the settings. 11. If the sequencer measures a pressure drop that is lower than the preset limit value, a subsequent cleaning will start.

Std. = 0,05 kPa12. Delayed alarm: 30 sec., 0 = active, 1 = off.13. Hour counter: up to 999 hours.14. Time counter15. Paus duration between subsequent cleaning cycles 1-250 s. The pause time between the subsequent cleaning

cycles of each cartridge. Std. = 20 s. When the setting is done, the control unit is started and the programmed data is stored by pressing the ”E” keypad

for 3 s. Ld2 should be green while the pressure-controlled regulation is in operation. If Ld2 is red, press the ”E”

keypad again. With the sequencer activated, a ”--” (fi lter unit switched off) or ”P” (fi lter unit in operation) will light up at the right in the display.

To enter settings:E Stops or starts the automated pulse-cleaning system when the keypad is pressed for 3 s.</> The arrow keypads are used for advancing to the next and returning to the previous line for settings respectively. There are 15 lines+/- The + keypad is used to increase and the - keypad is used to decrease the value of the setting on the line displayed. Light-emitting Diodes: kPa Normally shines with a steady green glow. This LED will fl ash together with the pressure reading in the display if the differential pressure exceeds the alarm level.Ld2 Green = Pressure-controlled cleaning Red = Time-controlled cleaning or the microprocessor is switched out in the pressure controlled cleaning mode.

Rights reserved for modifi cations in design and measurements.

K1-terminal 4/5: Closed when under voltage.K2-terminal 6/7: External alarm. Closed, when the alarm level is exceeded (row 6).D5-terminal 12/13: Clamped from factory.

Can be used for external pressure control of the pressure tank. Low pressure = open contact, the cleaning cycle is stopped. Suffi cient pressure = closed contact, the cleaning cycle is started. D6-terminal 13/14: External start and stop of the cleaning cycle. Open = cleaning cycle is stopped, closed = cleaning cycle is started. Clamped from factory.

Cleaning valvesCleaning valves

D5 D6