TurboNews_TCS-PTG_05-2006

Embed Size (px)

Citation preview

  • 8/13/2019 TurboNews_TCS-PTG_05-2006

    1/2

  • 8/13/2019 TurboNews_TCS-PTG_05-2006

    2/2

    The additional power output from the TCS-PTG system is in the form of

    50 or 60 Hz electrical energy for the onboard power grid. The power turbine

    is inserted into the exhaust gas system parallel to the turbocharger. It drives

    an electrical generator via a reduction gearbox and receives up to 13% of

    the exhaust gas flow, diverted from the main engine exhaust gas receiver.

    With this TCS-PTG stand alone solution in operation, auxiliary engine fuel

    and maintenance costs can be saved, CO2emissions reduced and gener-

    ator set maintenance more flexibly planned and carried out with the ship

    underway!

    Used in combination with MAN Diesel high efficiency turbo-chargers on themain engine, and depending on fuel oil prices, payback periods as short as

    3 to 5 years can be achieved.

    The TCS-PTG system is recommended for engines with rated outputs

    above 20 MW and in marine applications where the onboard electrical load

    is in excess of 10% of main engine power.

    Save your money and save your environment with MAN Diesel TCS-PTG

    Systems. Economically and ecologically optimised vessel. Make your vessel

    an ECO-Vessel.

    Please contact:

    MAN Diesel SEStadtbachstr. 1

    86224 Augsburg

    Germany

    Phone +49 821 322-0

    Fax +49 821 322-3382

    E-Mail: [email protected]

    www.mandiesel.com

    MAN Diesel TurboNews

    TCS-PTG Turbo Compound Systems>>A Proven Method of Increasing Efficiency

    in 2-Stroke Diesel Power Systems

    About MAN Diesel

    MAN Diesel is the worlds leading provider of large-bore diesel engines. The company designs two-stroke and four-stroke diesel engines, generating sets and turbochargers, for manufacture

    by MAN Diesel and its licensees. The engines have outputs ranging from 450 to 97,300 kW. MAN Diesel has approximately 6,400 employees, located in Germany, Denmark, the UK, France,

    the Czech Republic and China. The companys worldwide service organisation, MAN Diesel PrimeServ, consists of a network of own service centres, supported by authorised partners.

    MAN Diesel is a subsidiary of the German industrial group MAN AG which is listed on the DAX stock index comprising the 30 largest companies in Germany.

    Rated outputs of TCS-PTG turbo compound system and PTG power turbine and gearbox combinations.

    Radial flow turbine Max. output Max. flow rate Max. speed

    kW kg/s PT 1/min

    T= 3.3 Temperature before turbine 450C

    PTG14 330 2,0 49,500

    PTG16 510 3,0 41,000

    (TCS-) PTG18 (700) 720 4,3 34,000

    (TCS-) PTG20 (1,050) 1,100 6,3 28,500

    (TCS-) PTG22 (2,200) 2,270 13,0 21,500

    Axial flow turbine

    (TCS-) PTG55 (3,300) 3,400 19,0 17,000

    (TCS-) PTG66 (4,700) 4,850 27,0 14,500MAN Diesel PTG power turbine with axial flow turbine

    and gearbox for up to 4,850 kW output.