    ANEXO A: BASE DE DATOS DE TASAS DE FALLAS PARA EQUIPOS E INSTRUMENTOS

    Tabla A.1. Tasas de falla de los equipos e instrumentos.

    DU DD SU SD tot1,03E-07 4,80E-08 1,18E-07 2,65E-07 5,34E-07

    3,70E-08 3,56E-07 1,43E-07 0,00E+00 5,36E-075,75E-06 0,00E+00 5,75E-06 0,00E+00 1,15E-05

    3,70E-08 3,56E-07 1,43E-07 0,00E+00 5,36E-071,57E-07 1,41E-06 1,57E-06 0,00E+00 3,14E-06

    1,24E-07 1,11E-06 1,24E-06 0,00E+00 2,47E-069,62E-06 0,00E+00 6,00E-05 0,00E+00 6,96E-05

    2,89E-07 0,00E+00 4,80E-08 3,71E-07 7,08E-071,00E-07 0,00E+00 1,97E-07 0,00E+00 2,97E-07

    2,85E-06 0,00E+00 2,85E-06 0,00E+00 5,71E-061,70E-06 0,00E+00 7,72E-05 0,00E+00 7,89E-05

    2,05E-06 0,00E+00 1,94E-05 0,00E+00 2,14E-050,00E+00 0,00E+00 5,71E-06 0,00E+00 5,71E-06

    FUENTE

    Proveedor - GenricoOredaOreda

    Exida / Oreda

    OredaExida / OredaProveedor - Rockwell

    Exida / Oreda

    ISA

    Proveedor - RockwellOredaExida / OredaExida / Oreda

    PLC: Control Logix (escenario 2 y 3)SDV: Generico - Gate valveSPA: Moore Industries - SPA/HL AO/4HS/CE-TX

    Power Supply: GenericoMotor: Genrico - Elctrico para bomba

    PT: Rosemount - 3051C (escenario 1)

    PSHH: Generico (escenario 1)PT/PSHH: para SIF con SIL 2 (escenario 2 y 3)PLC/RIO: Control Logix (escenario 1)

    PT: Rosemount - 3051C para SIF con SIL 2 (escenario 2 y 3)

    SY: ASCO - 8320VSD: GenericoBomba: Generico - Centrfuga manejo de crudo

    MARCA - Modelo

    Tabla A.2. Clculo de la Tasas de falla del sistema de control por PLC/RIO, para el escenario 1A y 1B.

    DESCRIPCIN MODELO DU DD S tot FuenteTablero de Control PLC:ControlLogix Chassis 1756-AXX 1,375E-09 1,2375E-08 1,38E-08 2,75E-08 Rockwell AutomationControlLogix Controller 1756-l61 6,15E-08 5,535E-07 6,15E-07 1,23E-06 Rockwell AutomationRedundant ControlNet Bridge 1756-CNBR 1,61E-08 1,449E-07 1,61E-07 3,22E-07 Rockwell AutomationIsolated Relay Output 1756-OW16I 3,675E-08 3,3075E-07 3,68E-07 7,35E-07 Rockwell AutomationTotal Tablero de control PLC 1,16E-07 1,04E-06 1,16E-06 2,31E-06

    Tablero de Control RIO:ControlLogix Chassis 1756-AXX 1,375E-09 1,2375E-08 1,38E-08 2,75E-08 Rockwell AutomationRedundant ControlNet Bridge 1756-CNBR 1,61E-08 1,449E-07 1,61E-07 3,22E-07 Rockwell AutomationIsolated Analog Input 1756-IF16 2,39E-08 2,151E-07 2,39E-07 4,78E-07 Rockwell AutomationTotal Tablero de control RIO 4,14E-08 3,72E-07 4,14E-07 8,28E-07TOTAL CONTROL POR PLC/RIO: 1,57E-07 1,41E-06 1,57E-06 3,14E-06

  • La informacin del presente documento es propiedad exclusiva de PETROAMAZONAS S.A. y no deber ser usada para otros propsitos distintos a los especificados.

    Tabla A.3. Clculo de la Tasas de falla del sistema de control por PLC, para el escenario 2.

    DESCRIPCIN MODELO DU DD S tot FuenteTablero de Control PLC:ControlLogix Chassis 1756-AXX 1,375E-09 1,2375E-08 1,38E-08 2,75E-08 Rockwell AutomationControlLogix Controller 1756-l61 6,15E-08 5,535E-07 6,15E-07 1,23E-06 Rockwell AutomationIsolated Relay Output 1756-OW16I 3,675E-08 3,3075E-07 3,68E-07 7,35E-07 Rockwell AutomationIsolated Analog Input 1756-IF16 2,39E-08 2,151E-07 2,39E-07 4,78E-07 Rockwell AutomationTOTAL CONTROL POR PLC: 1,24E-07 1,11E-06 1,24E-06 2,47E-06

    B130-FLD-60-ST-001-0 22B130-FLD-60-ST-001-0 23