Radiation. Safety.
Portable Instruments & Area Monitors
Radiation. Safety.
Portable Instruments | Smart Meters: RDS-31radiation detected:• Gamma and X-ray: 48 keV to 3 MeV
detector(s):• internal energy-compensated GM
tube• smart external detectors
• Frisker• GM Tube• Silicon Diode (60 keV to 6 MeV)
measurement range:• dose rate: 0.01 μSv/h to 0.1 Sv/h
(1 μRem/h to 10 Rem/h)• accumulated dose: 0.01 μSv to
200 Sv (1 μRem to 20,000 Rem)
Alarm indicators:• Visual (LED), audible (speaker),
tactile (vibration)• Optional internal WRM2 radio (900
MHz and 2.4 GHz)
Radiation. Safety.
Portable Instruments | Smart Meters: RAMR-200
radiation detected:• Gamma and X-ray: 60 keV to 2
MeV
detector:• energy-compensated GM tube
• External Smart Detectors (Frisker, High range GM detectors)
measurement range:• dose rate: 0.01 mSv/h to 1 Sv/h (10
μRem/h to 100 Rem/h)• accumulated dose: 0.01 mSv to
800 Sv (10 μRem to 80,000 Rem)
alarms:• User-adjustable setpoints for dose
rate and accumulated dose
Radiation. Safety.
Portable Instruments | Handheld: TelePole WR
radiation detected:• Gamma and X-ray: 70 keV to 2
MeV
detector:• two energy-compensated GM tubes
measurement range:• dose rate: 0.5 μSv/h to 10 Sv/h
(0.05 mRem/h to 1,000 Rem/h)• accumulated dose: 0.01 mSv to
800 Sv (10 μRem to 80,000 Rem)
additional:• Data-logging functionality• Short Pole option• Alarm setpoints for dose rate and
accumulated dose• WRM2 transmitter option
Radiation. Safety.
Portable Instruments | Handheld: RDS-30
radiation detected:• Gamma and X-ray: 48 keV to 1.3
MeV
detector:• energy-compensated GM tube
measurement range:• dose rate: 0.01 μSv/h to 100 mSv/h
(1 μRem/h to 10 Rem/h) • accumulated dose: 0.01 μSv to 1
Sv (1 μRem to 100 Rem)
alarm levels:• User-adjustable alarm setpoints for
dose rate and accumulated dose
Radiation. Safety.
Portable Instruments | Handheld: AMP 50/100/200
Common characteristics:
• Gamma and X-ray: 70 keV to 2 MeV• Waterproof probe head• Optional WRM2 External Transmitter• Optional cable lengths (25 to 250
feet)• AC and battery powered
AMP-50:• 0.1 μSv/h to 40 mSv/h (10 μRem/h to
4 Rem/h)
AMP 100:• 0.5 mSv/h to 10 Sv/h (5 mRem/h to
1,000 Rem/h)
AMP 200:• 0.5 mSv/h to 100 Sv/h (5 mRem/h to
10,000 Rem/h)
Radiation. Safety.
Portable Instruments | Handheld: RDS-80A
radiation detected:• Alpha: >2 MeV• Beta: >100 keV• Gamma and X-ray: 5 keV to 1.3
MeV
detector:• End window GM tube• 1.5 to 2 mg/cm2 MICA window
measurement range:• 1 CPM to 100,000 CPM• 0.1 DPM to 1,000,000 DPM
Alarm indicators:• Visual (LED) and audible (speaker)
Radiation. Safety.
Portable Instruments | New Ion Chamber – RI02
Radiation. Safety.
Portable Instruments | Area Monitors: DRM-1
radiation detected:• Gamma and X-ray: 70 keV to 2 MeV
detector:• two energy-compensated GM tubes
measurement range:• dose rate: 0.5 μSv/h to 10 Sv/h (0.05
mRem/h to 1,000 Rem/h)• accumulated dose: 0.01 mSv to 800 Sv
(10 μRem to 80,000 Rem)
Alarm Indicator:• Separately locatable alarm module
includes dose rate display, Speaker, and bright Red / Green lamps
• Integrated WRM2 transmitter (900 MHz or 2.4 GHz)
Radiation. Safety.
Portable Instruments | Area Monitors: DRM-2
DRM-2:
• 0.5 μSv/h to 10 Sv/h (0.05 mRem/h to 1,000 Rem/h)
• Two energy-compensated GM tubes• Integrated WRM2 transmitter (900 MHz or
2.4 GHz) Display with audible and visual alarms
• AC and battery-backup powered
DRM-2D:
• 0.01 μSv/h to 100 μSv/h (1 μRem/h to 10 mRem/h)
• One CsI detector• WRM2 Radio• Display with audible and visual Alarms• AC and battery-backup powered• Integrated WRM2 transmitter (900 MHz or
2.4 GHz)
Radiation. Safety.
Portable Instruments | Area Monitors: DRM-2E
radiation detected:• Gamma and X-ray: 70 keV to 2 MeV
detector:• two energy-compensated GM tubes –
externally locatable into inhospitable areas
measurement range:• dose rate: 0.5 μSv/h to 10 Sv/h (0.05
mRem/h to 1,000 Rem/h)• accumulated dose: 0.01 mSv to 800
Sv (10 μRem to 80,000 Rem)
additional:• Integrated WRM2 transmitter (900 MHz or
2.4 GHz)
• External detector can be located 25 feet to 250 feet away from the meter
Radiation. Safety.
Portable Instruments | RDS-31iTx-AM
Radiation. Safety.
Area Monitors | Perimeter Systems – Near Boundary Monitor
• Integrated DRM-2 detection: 0.5 μSv/h to 10 Sv/h (0.05 mRem/h to 1,000 Rem/h)
• WRM2 radio or cell modem transmission
• Solar-powered – no AC required
• Back-up battery charges in environments to -40oC
• Fully self contained apparatus