SDR Configuration
)
SDR Configuration
Version Date Author Approved By Remarks
SDR Configuration
CONTENTS1 TOPLOGY.......................................................................................................................................3
2 CONFIGURE TRANSMITION BY LMT....................................................................................4
2.1 INSTALL LMT SOFTWARE..........................................................................................................42.2 START LMT...............................................................................................................................42.3 MAKE OFLINE CONFIGURATION.................................................................................................4
2.3.1 Define template by BTS type.................................................................................................52.3.2 Basic attribute.......................................................................................................................62.3.3 Rack configuration................................................................................................................82.3.4 E1 Link................................................................................................................................102.3.5 HDLC..................................................................................................................................102.3.6 PPP or ML-PPP..................................................................................................................102.3.7 Global Port..........................................................................................................................112.3.8 IP.........................................................................................................................................122.3.9 SCTP...................................................................................................................................122.3.10 OMCB Link.....................................................................................................................132.3.11 RRU Common Parameters.............................................................................................142.3.12 Toplogy............................................................................................................................152.3.13 GSM Sector.....................................................................................................................152.3.14 GSM RU..........................................................................................................................152.3.15 GSM Carries...................................................................................................................162.3.16 Save the configuration....................................................................................................17
2.4 DOWNLOAD CONFIGURATION TO SDR....................................................................................182.4.1 LMT connect.......................................................................................................................182.4.2 Connect to master CC board by LMT and import configuration........................................19
3 CONFIGURATION IN OMCR...................................................................................................20
3.1 TRANSMITION CONFIGURATION...............................................................................................203.1.1 Configure PCM link in DTB for Layer 1(physical layer)...................................................203.1.2 Configure HDLC link in EUIP for Layer 2(HDLC layer)..................................................213.1.3 RPU IP of EUIP..................................................................................................................213.1.4 Configure PPP link for Layer 3 (PPP layer)......................................................................223.1.5 IP Abis Bandwith Resource Pool........................................................................................23
3.2 SITE CONFIGURATION..............................................................................................................243.2.1 Creat Site.............................................................................................................................243.2.2 Creat Cell............................................................................................................................273.2.3 Creat TRX...........................................................................................................................29
4 CONFIGURATION IN OMCB....................................................................................................30
4.1 CREAT BASE STATION MANAGEMENT FOR SDR......................................................................304.2 UPLOAD CONFIGURATION FROM SDR BY ONLINE...................................................................31
1
SDR Configuration
4.3 BASE STATION EQUIPMENT RESOURCE MANAGEMENT..........................................................314.3.1 Rack configuration..............................................................................................................324.3.2 Transmition.........................................................................................................................35
4.4 BASE SATION RADIO RESOURCE MANAGEMENT.....................................................................384.4.1 RRU Common parameters..................................................................................................384.4.2 Toplogy................................................................................................................................394.4.3 GSM RU parameters...........................................................................................................404.4.4 GSM Sector.........................................................................................................................424.4.5 GSM Carrier.......................................................................................................................44
5 SDR DEBUG PROCESS..............................................................................................................45
5.1 STEP 1: CHECK TRANSMITION.................................................................................................455.1.1 Check E1 link status............................................................................................................455.1.2 Check transmition quality (after OMCB link connected)...................................................475.1.3 Check HDLC link................................................................................................................485.1.4 Check PPP link...................................................................................................................495.1.5 Check SCTP link.................................................................................................................495.1.6 Check OMCB link...............................................................................................................49
5.2 STEP 2: CHECK SOFTWARE (BY OMCR FOR BSC ENGINEER,BY LMT FOR BTS ENGINEER). 515.3 STEP 3: CHECK BORAD STATUS IN BBU..................................................................................51
5.3.1 CC board.............................................................................................................................515.3.2 FS board..............................................................................................................................515.3.3 UPBG board.......................................................................................................................525.3.4 FCE bord.............................................................................................................................52
5.4 Step 4: Check RRU status.......................................................................................................52
2
SDR Configuration
1 Toplogy
Figure 1 Toplogy of Site 67 in TINDOUF
Table 1 Intergrated parameters
Parameters Configuration of BTS Side Configuration of BSC Side Notes
GSM Site ID 67 67 Same in BTS and BSC
Site IP 116.18.67.100 116.18.67.100
RPU IP of Abis 116.18.1.1 116.18.1.1 Vitual IP of CMP
Local port of SDR 67 Same as Site ID is recomend
Remote port of SDR 14596 414592+CMP module Nuble
Defined in Ste configuration
OMCB IP 116.18.1.1 116.18.1.1 Can be same as RPU IP of Abis
BTS Type ZXSDR BS8800 GU360 ZXSDR BS8800 GU360
Case S4/4/4 3/3/3 GSM900M & GSM1800M
BCCH 85,87,89 & 756,766,761
E1 cable Link0 & Link1PCM13 of 211 & PCM 14 of
711Multiframe
HDLC TS 1-31 TS 1-31
ML-PPP Yes Yes
Port of ML-PPP 192
SDR Configuration
2 Configure transmition by LMT2.1 Install LMT software
2.2 Start LMT
2.3 Make ofline configuration
We can make ofline configuration at home for a lot of SDR sites, and save the configration. Connect PC with BBU for import configuration when SWAP
4
SDR Configuration
2.3.1 Define template by BTS type
Select template by reference BTS type (BS8700, BS8800, BS8900)
Notes:BS8700: BS8700_template_2uBS8800: BS8800_GU360_template_2u
5
SDR Configuration
BS8900: BS8900_GU360_template_2u
2.3.2 Basic attribute
Notes: NodeB ID is not allowed to configure for 2G.
6
SDR Configuration
Notes: Configure Transmission Mode to ‘IP’ for IPOE
Notes:
7
SDR Configuration
Radio Mode : Set ‘GSM’ for 2GGSM Station NO: same as ‘SITE ID’ given by BSC engineerE1/T1 Medium :Set ‘E1’ for IPOE
Notes: ATM is used for 3G
2.3.3 Rack configuration
2.3.3.1 BBU Rack
8
SDR Configuration
2.3.3.2 RRU Racke
2.3.3.3 Antenna
9
SDR Configuration
2.3.3.4 FCE & PDM
2.3.4 E1 Link
2.3.5 HDLC
2.3.6 PPP or ML-PPP
ML-PPP is used in this case, it includes 2 HDLC links (E1 calble)
10
SDR Configuration
2.3.7 Global Port
11
SDR Configuration
2.3.8 IP
2.3.9 SCTP
12
SDR Configuration
Notes:Local Port ID: Site ID Remote port: 14592+CMP Module NO.
2.3.10 OMCB Link
13
SDR Configuration
2.3.11 RRU Common Parameters
Creat commom parameters for RRU1~RRU6
14
SDR Configuration
2.3.12 Toplogy
2.3.13 GSM Sector
2.3.14 GSM RU
15
SDR Configuration
2.3.15 GSM Carries
16
SDR Configuration
2.3.16 Save the configuration
17
SDR Configuration
2.4 Download configuration to SDR
2.4.1 LMT connect
Connect PC to BBU at ETH1 of CC board by internet cable (direction cable almost)The master CC is in solot 1, and its mantaince IP is 192.254.1.16 by default difination .Set the PC and CC in same gateway and do ping test.
18
SDR Configuration
2.4.2 Connect to master CC board by LMT and import configuration
19
SDR Configuration
After import configuration,BBU will restart automatically3 Configuration in OMCR3.1 Transmition Configuration
3.1.1 Configure PCM link in DTB for Layer 1(physical layer)
20
SDR Configuration
3.1.2 Configure HDLC link in EUIP for Layer 2(HDLC layer)
HDLC NO: number of HDLC, defined by userEUIP 2MHW NO: number of EUIP 2MHW, defined by userNotes: DTB and EUIP shoulde be in the same shelf
3.1.3 RPU IP of EUIP
21
SDR Configuration
Notes:Port NO: defined by BSC engineer ,1-190 for PPP,191-254 for ML-PPP
3.1.4 Configure PPP link for Layer 3 (PPP layer)
3.1.4.1 IP Over E1 Configuration
Notes:Port NO: defined by BSC engineer,but the number shoul be uniqueHDLC NO: use ‘HDLC NO’ defined in EUIP
22
SDR Configuration
3.1.4.2 PPP Configuration
Notes:MP NO.Sign: valid for ML-PPP, invalid for PPPPeer IP: IP address of SITEMP No: used ‘Port NO’ defined in EUIP_RPU
3.1.5 IP Abis Bandwith Resource Pool
23
SDR Configuration
Notes: Mode NO: used CMP modue NOUplink/Down link bandwith : decied by case,for 1 E1 is 2048 ,for 20480 for 10 E13.2 Site Configuration
3.2.1 Creat Site
24
SDR Configuration
25
SDR Configuration
Notes: Site ID: Defined by BSC engineerModule NO: use the CMP module defined in Rack
26
SDR Configuration
Notes:Site IP address: IP address of SDR
3.2.2 Creat Cell
27
SDR Configuration
28
SDR Configuration
3.2.3 Creat TRX
29
SDR Configuration
Notes:Port NO: defined by BSC engineer,a connection informationTRX Group NO: define the TRX to access the DSP of BIPB (IP support) , it is safe that difen different TRX in different DSP
4 Configuration in OMCB4.1 Creat Base Station management for SDR
30
SDR Configuration
4.2 Upload configuration from SDR by online
31
SDR Configuration
4.3 Base Station Equipment Resource Management
4.3.1 Rack configuration
32
SDR Configuration
4.3.1.1 BBU rack
33
SDR Configuration
4.3.1.2 RRU rack
4.3.1.3 FCE and PDM
34
SDR Configuration
4.3.1.4 Antenna
4.3.2 Transmition
4.3.2.1 E1 link
35
SDR Configuration
4.3.2.2 HDLC link
4.3.2.3 PPP
36
SDR Configuration
4.3.2.4 Global Port
4.3.2.5 IP parameter
37
SDR Configuration
4.3.2.6 SCTP
4.3.2.7 OMCB link
4.4 Base Sation Radio Resource Management
4.4.1 RRU Common parameters
38
SDR Configuration
4.4.2 Toplogy
39
SDR Configuration
4.4.3 GSM RU parameters
40
SDR Configuration
41
SDR Configuration
4.4.4 GSM Sector
42
SDR Configuration
43
SDR Configuration
4.4.5 GSM Carrier
44
SDR Configuration
5 SDR Debug Process5.1 Step 1: Check transmition
Check connection and quality
5.1.1 Check E1 link status
5.1.1.1 Check E1 link status at BBU by LMT (BTS engineer)
45
SDR Configuration
5.1.1.2 Check E1 link status at OMCR (BSC engineer)
46
SDR Configuration
5.1.2 Check transmition quality (after OMCB link connected)
5.1.2.1 Check E1 link quality at BBU (BTS engineer)
Check the quality of E1 link by telnet command when OMCB link is connectedtelnet 192.254.1.16 ;telnet to CC in solot 1CC->ping 116.18.1.1 ;ping RPU of Abis,and check whether there is lost packetCC->BspE1T1ErrPerformStart ;This command is to start check tranmistion qualityCC->E1ErrInfo ;After each 400 second,input this command for view the result. Do this check for
5-7 times, and save the results for report.tatistic Time:402slink ES SES BBE UAS FAS CRC Slip CV Ebit-------------------------------total stats:0 10 c 375 182 8367 20d85 0 244e2 4a
value = 86 = 0x56 = 'V'CC->E1ErrInfoStatistic Time:420slink ES SES BBE UAS FAS CRC Slip CV Ebit-------------------------------total stats:0 10 c 375 194 882a 221ef 0 25cba 4a
value = 86 = 0x56 = 'V'
Table 1 defination of “E1ErrInfo”
47
SDR Configuration
link ES SES BBE UAS FAS CRCSlip
CVEbi
t
E1 link
number
Error code
time(second)
Error code
check
time(second)
Error code
background
block
number
Link
unavailable
time
(second)
Frame
asynchronize
times
CRC
check
error
number
Slip
times
Codec
abnormal
times
Error
bits
number
CC->BspE1T1ErrPerformStop ;To stop the check process because this will affect CPU so much.
5.1.2.2 Check E1 link quality at OMCR (BSC engineer)
48
SDR Configuration
5.1.3 Check HDLC link
Only error configuration will lead to HDLC link work abnormally when E1 link is work normally
49
SDR Configuration
5.1.3.1 Check HDLC link status by LMT (BTS engineer)
Check alarm the same as E1link in CC board5.1.3.2 Check HDLC link status by OMCR (BSC engineer)
Check alarm the same as E1 link in EUIP board
5.1.4 Check PPP link
Only error configuration will lead to PPP link work abnormally when HDLC link is work normally5.1.4.1 Check PPP link status by LMT (BTS engineer)
Check alarm the same as HDLC link in CC board5.1.4.2 Check PPP link status by OMCR (BSC engineer)
Check alarm the same as HDLC link in EUIP and CMP board
5.1.5 Check SCTP link
Only error configuration will lead to SCTP link work abnormally when PPP link is work normallyCheck IP address, CMP module number, local port,remote port5.1.5.1 Check SCTP link status by LMT (BTS engineer)
Check alarm the same as PPP link in CC board5.1.5.2 Check SCTP link status by OMCR (BSC engineer)
Check alarm the same as PPP link in CMP board
5.1.6 Check OMCB link
Only error configuration will lead to OMCB link work abnormally when PPP link is work normally
50
SDR Configuration
5.1.6.1 Check OMCB link status by LMT (BTS engineer)
5.1.6.2 Check OMCB link status by OMCR (BSC engineer)
Check SDR’s IP address
51
SDR Configuration
5.2 Step 2: Check Software (by OMCR for BSC engineer,by LMT for BTS engineer)
After download the software by OMCR, BSC engineer shoul check the download result and make sure thar no software lostThen, active software for SDR
5.3 Step 3: Check Borad status in BBU
5.3.1 CC board
It will work normally almost, but we can check the tansmition alarm at this board.between BBU and BSC, between CC and other boards in BBU
5.3.2 FS board
Alarm Code solution notesBoard initial FS board is downloading software,just waitFS port ID Alarm Maybe RRU is starting,just wait;
Maybe RRU is power off;Maybe error connection between FS and RRU;
52
SDR Configuration
Maybe Fiber cable is broken;
5.3.3 UPBG board
Alarm Code solution notesBoard initial UPBG board is downloading software,just waitAttenna link error Maybe some RRU is working abnormally
5.3.4 FCE bord
Alarm Code solution notesBoard initial FCE board is downloading software,just waitControl link broken Maybe ,No air condition,high temprature
5.4 Step 4: Check RRU status
Alarm Code solution notesBoard initial RRU board is downloading software,just waitControl link broken between FS and RRU
Maybe , RRU is power off;Maybe , RRU is starting;Maybe, RRU is working with wrong software,reset RRU and downloadMaybe, RRU connect with wrong port of FS boardMaybe ,RRU is broken
VSWR Alarm Check antenna
5.5 Check Voice service
53
SDR Configuration
54