کنترل تطبيقى سيستمهاى HVAC. مراجع: Energy simulation of traditional vs. Adaptive thermal comfort for two moderate climate regions J.L.M. Hesen, L. Centnerova Advanced controller auto-tuning and its application in HVAC systems - PowerPoint PPT Presentation
Citation preview
1
سيستمهاى تطبيقى HVACکنترل
: مراجع
Energy simulation of traditional vs. Adaptive thermal comfort for two moderate climate regions
J.L.M. Hesen, L. Centnerova
Advanced controller auto-tuning and its application in HVAC systems
Qiang Bi, Wen-Jian Cai, Qing-Guo Wang, Chang-Chieh Hang, Eng-Lock Lee, Yong Sun, Ke-Dian Liu, Yong Zhang, Biao Zou
Intelligent Adaptive Control: Intelligent Control of Air Conditioning Systems
Jain; Lakhmi C., de Silva; Clarence W.
2
مقدمه
از چيست؟ HVACمنظورBiotherium چيست؟ حرارتى تعريف راحتى شرايط چيست؟ تنظيم خود سيستم يک چيست؟ هوشمند تطبيقى کنترل سيستم از منظور
3
بحث مورد مطالب
توليد کارخانه يک در مطبوع تهويه سيستم يکمصنوعى نخ
بينا مطبوع تهويه سيستم يک سوى به گامى
يک در مطبوع تهويه سيستم clean roomيک
4
با مصنوعى نخ توليد کارخانه يک در مطبوع تهويه سيستم يکقابليت
انرژى صرفهجويىTerephthalic acid
+
Ethylene glycol
(Raw material)
Polymerization
Process
Spinning
Process
Drawing/twisting
Process
Polyester
filament
Role of Air conditioning system:
Aging of yarn yet to be drawn Prevention of yarn from changing
physical properties before drawing Maintaining level of dyeing Prevention of occurrence of yarn cut
and fluff Purification of room atmosphere
[3]
5
انرژى صرفهجويى جهت فازى کنترل با مطبوع تهويه سيستم
6
فازى قوانين
7
نتايج
8
تشخيصموقعيت قابليت با مطبوع تهويه سيستمساکنان
1. Distinguish occupants from background in an image using the Fuzzy C-Means algorithm (FCM)
2. Distinguish each occupant by locating local temperature peaks in the image
3. Region growing for more accurate segmentation of occupants
9
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
1 81 84 82 64 68 74 75 80 74 72 73 69 85 75 76 77 77 80 83 75
2 78 82 82 71 73 71 63 73 72 62 72 66 78 78 69 83 86 84 83 76
3 80 72 82 74 82 73 70 71 74 62 55 59 96 101 111 132 118 84 71 68
4 71 75 77 65 71 75 72 72 66 42 38 80 164 162 131 113 86 74 68 66
5 78 76 69 55 63 120 151 135 93 66 66 79 107 108 98 93 91 81 82 80
6 53 69 77 32 50 149 215 207 133 84 73 70 70 67 63 65 73 78 84 78
7 54 78 87 51 47 121 186 197 138 71 71 58 66 70 72 65 69 82 89 85
8 62 72 76 57 65 79 92 102 86 64 65 56 64 67 64 72 73 76 82 73
10
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
1 81 84 82 64 68 74 75 80 74 72 73 69 85 75 76 77 77 80 83 75
2 78 82 82 71 73 71 63 73 72 62 72 66 78 78 69 83 86 84 83 76
3 80 72 82 74 82 73 70 71 74 62 55 59 96 101 111 132 118 84 71 68
4 71 75 77 65 71 75 72 72 66 42 38 80 164 162 131 113 86 74 68 66
5 78 76 69 55 63 120 151 135 93 66 66 79 107 108 98 93 91 81 82 80
6 53 69 77 32 50 149 215 207 133 84 73 70 70 67 63 65 73 78 84 78
7 54 78 87 51 47 121 186 197 138 71 71 58 66 70 72 65 69 82 89 85
8 62 72 76 57 65 79 92 102 86 64 65 56 64 67 64 72 73 76 82 73
11
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
1 81 84 82 64 68 74 75 80 74 72 73 69 85 75 76 77 77 80 83 75
2 78 82 82 71 73 71 63 73 72 62 72 66 78 78 69 83 86 84 83 76
3 80 72 82 74 82 73 70 71 74 62 55 59 96 101 111 132 118 84 71 68
4 71 75 77 65 71 75 72 72 66 42 38 80 164 162 131 113 86 74 68 66
5 78 76 69 55 63 120 151 135 93 66 66 79 107 108 98 93 91 81 82 80
6 53 69 77 32 50 149 215 207 133 84 73 70 70 67 63 65 73 78 84 78
7 54 78 87 51 47 121 186 197 138 71 71 58 66 70 72 65 69 82 89 85
8 62 72 76 57 65 79 92 102 86 64 65 56 64 67 64 72 73 76 82 73
12
با فازى رطوبت و دما کنترل سيستم يکيادگيرى قابليت
: معمول فازى کنترل سيستم
13
Temperature request and humidity request inference TRV: error of measured and desired temperature together
with its deviation HRV: foreseen error and deviation
Integrated inferenceIf x1 is Ai1, …, x5 is Ai5 then y1 is Bi1, …, y3 is Bi3
x1: last manipulated variable for the cooling valve
x2: last manipulated variable for the heating valve
X3: last manipulated variable for the humidifying valve
X4: temperature request
X5: humidity request
y1, y2, y3: change in manipulated variable for the cooling. heating and humidifying valve
14
يادگيرنده فازى کنترل سيستم
15
16
سازى شبيه نتايج
17
عملى نتايج
18
. سيستم يک نوعى HVACالف
[2]
Return to Introduction
19
. حرارتى راحتى شرايط ب“Condition of mind, which expresses satisfaction with the thermal
environment.” [1]
Criteria’s for thermal comfort (PMV index): Air temperature Radiant temperature Humidity Air velocity Personal parameters such as clothing and metabolic rate
Criteria’s for thermal discomfort: Draught High vertical temperature difference between head and ankles Too high radiant temperature asymmetry
“The optimum operative temperature for comfort is a function of metabolic rate and clothing insulation.” [1]
Return to Introduction