Совместный вебинар Teco + iRidium (часть Teco)

  • View
    65

  • Download
    26

Embed Size (px)

Text of Совместный вебинар Teco + iRidium (часть Teco)

  1. 1. Teco + iRidium mobile Tecomat Foxtrot Lubos Urban
  2. 2. : 12.00 - 12.05 Teco 12.05 - 12.20 Tecomat Foxtrot: , , , 12.20 - 12.35 Mosaic 12.35 12.45 Mosaic + iRidium
  3. 3. 2013 20- Teco 2007 Tecomat Foxtrot 2003 PLC Open, TC700 1997 Tecomat TC600, Geovap 1996 ISO 9001 1993 Teco . 1976 1966 NC (numeric control) 1945 TESLA Koln 1934 Prchal Ericsson 1919
  4. 4. Tradition & advantages 10 IEC EN 61131
  5. 5. Mosaic Tools Solutions Teco
  6. 6. Teco = Tecomat Tecomat = PLC PLC = IEC-61131 PLC () = 61 131 Tecomat ! Tecomat TC700 2000 /, Tecomat Foxtrot , : CIB-Common Installation Bus RFox Tecomat Ethernet/web Tecomat TC700 Tecomat Foxtrot Teco = Tecomat
  7. 7. , , , HMI , , Tecomat Foxtrot =
  8. 8. Tecomat Foxtrot 10
  9. 9. LCD LCD CP-1003 8x AI/DI, 8xDI (HSC) 8x RO, 4x DO (HS), 4x AO 32x I/O 2x TC2 CP-1000 4x AI/DI 2x DI (230V AC) 2x RO 8x I/O 1x TC2, 2x CIB CP-1014 8x DI (4xAI) 6x RO CP-1004 14x I/O 1x TC2, 1x CIB CP-1015 CP-1005 6x AI/DI 6x RO 2xAO 14x I/O 1x TC2, 1x CIB CP-1016 CP-1006 13x AI/DI 1x DI (230C AC) 1x DI (HSC) 10x RO 2x SSR 2x AO 29x I/O 1x TC2, 1x CIB CP-1018 CP-1008 10x AI/DI 2x AI 1x DI (230V AC) 7x RO 4x SSR 4x AO 28x I/O 1x TC2, 1x CIB Tecomat Foxtrot CP-1001
  10. 10. TCL2 - RS485, 300-400 , 5 1750 , . , , . 4 + 6 . 4 /, . 10 2x CIB RFox Open therm MP bus TCL2 fibre optic TCL2 TCL2, 400m 12 DI 12 DO 4DI, 8RO 8AI, 2AO 8AI, 2AO 120 terminal of TCL2 bus 8AI, 2AO SC UART 120 terminal of TCL2 bus Foxtrot TCL2
  11. 11. TCL2 - RS485, 300-400 , 5 1750m, . , branching Operator panels Max. 4 / , . 20 2x CIB RFox Open therm MP bus TCL2 TCL2 TCL2, 400m 12 DI 12 DO 4DI, 8RO 8AI, 2AO 8AI, 2AO 120 TCL2 8AI, 2AO SC UART 120 TCL2 120 TCL2 TCL2B TCL2A FOXTROT CP-1003: 2x TCL2 -> 2x /
  12. 12. CFox / RFox
  13. 13. 2xAI/DI 1x RO, 1x AO CIB , 300-400 7-150 DIN 6RO,3AI/DI , 2AO 8RO 10+1RO, 3AI, 8DI, 2AO 16+3 RO, 3AI, 8DI, 2AO 6x LED belt 6x LED chip 2x DIM 2xTla 2xTi 1x IR in/out 1x Light in 1x Ti 1x Ti, 1x Light in 4xTla 2x Ti 2xTi 3x Tl, 1xdisp., 2xTi 1x PIR 1x disp, 1x rot. button 2xAI/DI DALI, 12x 5xAI/DI 4x AO 1x IR in,1x IR out, 1x Light in, 1xTi, 2x inVENTer 9xAI/DI 8x LED 2x Ti2x Ti 2x Ti Radiator valve 0-100% CO2, Smoke VOC, Humidity2x AI 2x Ti 1x rotation button 2x Ti 1x DIM 2x Ti, 1x DI 1x AO/PWM, 2x RO 2x RO 2x AI/DI Foxtrot / CIB
  14. 14. Inputs, Outputs, Switching, Relays Relay 3I/8O 11I/13O 8RO 6x U LED Hotel modules 2DI/AI 2I/2O Dimming Dimming 12x DALI 1 IR Wall switches Temperature setting and correction Metering Remote control CIB overvoltage protection Interior modules Modules built-in to installation box Modules on DIN rail into switching cabinet Power supply CIB CIB separation module power supply Other modules on CIB, max.32 CIB : CF-1141 2 CIB . 4 s CF-1141, 8 IB Combined sensors CIB1 CIB8-9CIB2-3 CIB4-5 CIB6-7 5I/4O 9I/8O 2I/2RO 1I/2O 11I/21O 6x I LED 4xAI FanCoil Special Ventillation Security Detectors 1x Wiegand Tecomat Foxtrot CIB
  15. 15. 3AI, 6DI, 10RO, 2 AO 4DI 1RO . RFox : 868MHz FSK ( ) 64 RFox / 1 . 4 / 1 RF RF6RF0 RF2 RF4 1x RFox 3x CIB 2x RFox 2x CIB 3x RFox 1x CIB 4x RFox 3AI, 13DI, 19RO, 2 AO Foxtrot and wireless network RFox
  16. 16. 2) SET 1) RFox CLICK ! CLICK ! CLICK ! CLICK ! CLICK ! CLICK ! CLICK ! CLICK ! CLICK !
  17. 17. 1) RFox (.4) CLICK ! CLICK ! CLICK ! CLICK ! Bonding, routing
  18. 18. FOXTROT Tecomat Foxtrot:
  19. 19. Foxtrot integration with other systems
  20. 20. Wall switches in different designs KNX
  21. 21. ( iPad, Android)
  22. 22. ON/OFF Switching 230 V AC, 12 V DC Bulbs 230V Bulbs 12V with coiled transformers Bulbs 12V with electronic transformers Fluorescent lamps Compact fluorescent lamps Switching power supplies 230 V/12V for LED Dimming Dimming RGB LED stripes 12V/24V controlled by voltage Dimming of RGB LED chips controlled by current 150/350/500/700mA Dimming fluorescent lamps via DALI ballasts Dimming fluorescent lamps via 1-10V ballasts Dimmer C-DM-0402M for R, L, C Loads 230V 2x 500W, paralell work of more dimmers Dimming and control over two DMX512 channels Lighting actors
  23. 23. C-DL-0064M Controller for 64 DALI ballasts C-DL-0012S for 12 DALI ballasts
  24. 24. CIB bus couplers for different designes of world leaders Gira 2003 Gira Jung Wall switches the basic HMI - interface CFox interior wall switches on order
  25. 25. Direct control of AC motor AC Asynchronous drive Voltage is applied on two different coils of the drive N Direct control of DC motor DC drive Control of the direction by changing the voltage polarity M 230V N L Jalousie, rollers, marquise, shading
  26. 26. Certified security systems has to be communicated Communication Serial port, Ethernet Tecnoalarm DSC Paradox Galaxy (Honeywell) Jablotron Individual detectors connection Module C-IT-0200S with universal AI/DI inputs Simple ballanced input Double ballanced inputs Module C-WG-0503S Specialized for security detectors Reads Alarm and Tamper signals Contains 12V power supply derived from 24V of CIB wires. Wiegand port for acces system, keyboards Security detectors Fire detectors Security, Fire alarm systems
  27. 27. IT-100 PC1616 PC1832 PC1864 PK5500 Tecomat Foxtrot CP-10xx RS-232 DSC security system certified
  28. 28. RFID card readers (125kHz, Mifare) Connected via C-WG-0503S module Connected via Wiegand protocol RFID card reader with the keyboard Access control
  29. 29. Aperio C100 Aperio A100 HUB Wiegand C-WG-0503S HUB Wiegand C-WG-0503S Wireless key APERIO (simple access system) by Assa Abloy
  30. 30. General purpose IR transmitte/ receiver C-RI-0401S Embedded module IR receiver learning mode IR transmitter sending learned commands according the user program + temperature sensor + light intensity sensor C-RI-0401R Interior housing Designed for Control of Air Condition indoor unit Control of audio video devices with IR input Any other device with IR input Termostats, for clima control RCM2 LCD Display with icons Rotary element with acknowledgement button Integrated temperature sensor CIB version RFox version C-RC-0002R LCD numeric display 3 buttons Integrated temperature sensor Other controls /modules
  31. 31. Sensors with integrated CIB interface For interior With IP65 Outdoor Contact For air pipeline For sleeve Table of connectivity of different sensors to different modules Pt1000 Ni1000 020mA 010V Termolnky kondenzace internidlo vyvenvstupy -1V1V -2V2V 1 1 2 2 2 2 2 2 2 2 2 2 2 2 2 2 5 5 5 5 5 5 5 1 1 1 RCM2-1 1 1 2 2 2 2 2 2 2 2 1 2 2 2 2 1 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 1 1 1 1 1 1 2 2 2 2 2 2 2 2 4 4 4 4 4 4 4 4 4 5 5 5 5 5 5 5 1 5 5 1 2 2 2 2 2 0/1 2 2 2 2 2 2 2 2 2 1 1 1 1 1 1 NTC12k NTC515k KTY81-121 Odpor0200k Odpor0600k Odpor06M DI,kontakt -100mV100mV idlorosenSHS C-IT-0200R C-IT-0200S C-IR-0202S C-IT-0504S C-IT-0908S C-RC-0002R C-IT-0200I C-IT-0100H C-HM-0308M C-HM-1113M C-HM-1121M C-HC-0201F-E C-WS-0200R C-WS-0400R C-FC-0024X C-VT-0102B C-AM-0400M C-AM-0600I C-RI-0401 C-OR-0202B R-IT-0100R R-IT-0100H-A R-RC-0001R R-HC-0201F ROZSAH MODUL Temperature sensors
  32. 32. Foxtrot control the heat exchangers in the rooms Radiators Thermostatic head wiress / wireless Head on/off, proporcional (0-100%) Floor convectors FanCoils Floor water heating Floor electric heating Convector heater Ceiling cooling Air conditioning units LG, Samsung direct communication Others: IR remote control Foxtrot control and coordinate the source of heat Heat pumps PZP, AC Heating, ACOND, NEOTA, NUKLEON, REGULUS Gas boilers (Opentherm) Coal and pelets boilers Central heating exchanger Combination with solar systems Accumulation tanks Warm water HVAC in the house
  33. 33. Switching/dimming Control Measuring clima parameters Heaters, ventilators/other technologies Monitoring, settings WiFi RFox RFox Ethernet 100M CIB CIB CO2, RH, Temperature wired Wireless Hierarchy of centralized control of HVAC in the house
  34. 34. Control of recuperation unit Module C-HM-0308M 3 AI/DI, one input for high ohmic sensors Condensation sensor Driving the shutters 1 point, 3 points 2-3 temperature sensors Control of 2 EC motors of two fans SW control Ventilation with heat (cold) recuperation, Night pre cooling of the building by the night cool outdoor air Ventilation with recuperation
  35. 35. Electricity metering via secondary meters Module C-AM-0600I 5 counters/analogue inputs 1 phase meter S0 pulses 1 Phase reading opto (IR) head over serial port 3 phase reading RS-485 or M-bus Tecometer: direct reading of AMM meter by ZPA Wireless reading meter Display current consumption on TV via HDMI Graphs and recalculation consumption to money CZK/EUR/USD/ etc. Energy measurement (smart metering)
  36. 36. Water flow meters Counting pulses from water meters It is prepared reading via Wireless M-bus Vortex flow meter analog output Gas flow meters Reading the pulses Wireles M-bus reading Water and Gas metering
  37. 37. DC electricity meter for photovoltaic panels SMM33 3phase measuring of current, voltage, current, power Harmonic distorsion measurement Communication of serial port Special metering of electricity
  38. 38. Heat measuring heat meter Version: using certified calorimeter over the M-bus (Serial port) Connection of the flowmeter (V) and two temperature sensors on input (Tp) and outpus (Tz) at the module C-AM-0600I Fox

Search related