CONTIGUOUS
PILES
PILECAP4320x3270x900DP
4
S/04
2
S/02
SCALE 1:50
LOWER BASEMENT LAYOUT
SSL -10.345
SSL -10.345
SSL -10.345
SSL -10.795
SSL -10.795
750x600 GROUNDBEAM
750x600 GROUND BEAM
750x600 DEEPGROUND BEAMUNDER
750x600 DEEPGROUND BEAM
750x600 DEEPGROUND BEAM
RC WALL
RC WALL
RC WALL
RC WALL
750x600 mmGROUND BEAM
SSL -10.345
SSL -10.345
15
16
1 2 3 4 5 6
17 18 19
20 21 22
2324
101112
25
1314
101102103104105106107108
109
110
111
112
113114115116117118119120121
123122
124
125
126
127
128
129130131132
133134135136137138139
140
141
3534
33
32
26 27 28
293031
PILECAP4320x3270x900DP
7
S/04
SSL -10.345
SSL -10.345
SSL -10.345
142
144
143
145146147148
5
S/04
8
S/04
150149
8
9
7
DRAINAGE LAYOUT TO BE REVISED
UP
PILE LOADING
PILEREFERENCE
MAX VERTICALDOWNWARD LOAD( kN ) UNFACTORED
MAX VERTICALUPLIFT LOAD
( kN ) UNFACTORED
1 925 -
2 925 50
3 950 -
4 950 -
5 1225 -
6 1225 -
7 1225 -
8 850 -
9 1225 -
10 1225 -
11 1225 -
12 950 -
13 950 -
14 925 50
15 925 -
16 850 125
17 850 400
18 850 400
19 850 400
20 625 -
21 625 -
22 625 -
23 75 -
24 75 -
25 75 -
26 625 -
27 625 -
28 625 -
29 75 -
30 75 -
31 75 -
32 300 -
33 300 -
34 300 -
35 300 -
PILE LOADING PILE CO-ORDINATES
PILEREFERENCE
MAX VERTICALDOWNWARD LOAD( kN ) UNFACTORED
MAX VERTICALUPLIFT LOAD
( kN ) UNFACTOREDNORTHING EASTING
101 75 - 179261.870 525290.050
102 75 - 179262.180 525289.902
103 75 - 179262.490 525289.754
104 75 - 179262.799 525289.606
105 75 - 179263.109 525289.458
106 75 - 179263.419 525289.310
107 75 - 179263.729 525289.163
108 75 - 179264.038 525289.015
109 75 - 179264.348 525288.867
110 75 - 179264.191 525288.545
111 75 - 179264.035 525288.224
112 75 - 179263.878 525287.902
113 75 - 179263.722 525287.581
114 75 - 179264.047 525287.424
115 75 - 179264.373 525287.268
116 75 - 179264.699 525287.112
117 75 - 179265.024 525286.956
118 75 - 179265.350 525286.800
119 75 - 179265.676 525286.643
120 75 - 179266.002 525286.487
121 75 - 179266.328 525286.331
122 75 - 179266.654 525286.175
123 75 - 179266.979 525286.018
124 75 - 179267.306 525285.863
125 75 - 179267.454 525286.168
126 75 - 179267.600 525286.468
127 75 - 179267.747 525286.768
128 75 - 179267.893 525287.068
129 75 - 179268.214 525286.911
130 75 - 79268.537 525286.754
131 75 - 179268.875 525286.590
132 75 - 179269.213 525286.425
133 75 - 179269.566 525286.254
134 75 - 179269.904 525286.089
135 75 - 179270.242 525285.925
136 75 - 179270.580 525285.761
137 75 - 179270.917 525285.596
138 75 - 179271.255 525285.432
139 75 - 179271.593 525285.267
140 75 - 179271.747 525285.584
141 75 - 179271.902 525285.901
142 75 - 179272.056 525286.217
143 75 - 179272.210 525286.534
144 75 - 179272.518 525286.385
145 75 - 179272.825 525286.235
146 75 - 179273.132 525286.086
147 75 - 179273.439 525285.937
148 75 - 179273.747 525285.787
149 75 - 179274.054 525285.638
150 75 - 179274.361 525285.489
DO NOT SCALE FROM THIS DRAWING
THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL SITEDIMENSIONS BEFORE COMMENCING ANY WORK
ALL DIMENSIONS IN mm UNLESS OTHERWISE NOTED ALL DIMENSIONS
AND LEVELS TO BE CONFIRMED
BY ARCHITECT SETTING OUT TO BE CONFIRMED ON SITE
FIDEL KARIM
STRUCTURAL
DRAWINGS
SCALEPAPER SIZEDATE
DRAWN CHECKED
DESCRIPTIONDATEREV
THIS DRAWING IS SUBJECT TO COPYRIGHT
-
37& 39
LONDON, W8
04/08/2014
LOWER BASEMENT
LAYOUT
GA/01 P6
-
FK --
A1 1:50
P1 04/08/14 INITIAL ISSUEP2 03/12/14 REVISED AS CLOUDEDP3 21/01/15 DIMENSIONS REMOVEDP4 06/07/15 GENERAL REVISIONSP5 14/07/15 REVISED AS CLOUDEDP6 13/08/15 LIFT & WALL POSITIONS REVISED
KEY
NEW LOAD BEARING STUD PARTITION
NEW LOAD BEARING BRICKWORK
EXISTING WALL
NEW LOAD BEARING CONCRETE WALL
NEW NON-LOAD BEARING STUD WALL
NEW LOAD BEARING BLOCKWORK
NEW NON-LOAD BEARING BLOCKWORK
UP
UP
UP
UP
UP
UP
1
S/01
6
S/01
3
S/03
WALL TIED
TO PILES
2
S/02
4
S/04
SCALE 1:50
MIDDLE BASEMENT LAYOUT
WALL UNDER
SSL -7.620
SSL -7.620
SERVICESVOID
SERVICES VOID
RC WALL
RC WALL
200mmRC WALLUNDER
200mmRC WALLUNDER
200mmRC WALLUNDERSSL -10.040
200 RC WALL
200mmRC WALL
RC WALL
SSL -10.040
SSL -8.970
SSL -8.970
ALLOW 50% MAXIMUM CLEAR VOIDFOR SERVICES ( HIT & MISS)
WALL UNDER
200mmRC WALLUNDER
3534
33
32
ALLOW 50% MAXIMUM CLEAR VOIDFOR SERVICES ( HIT & MISS)
RC WALL
300 RC WALL
7
S/04
5
S/04
8
S/04SSL -8.970
SSL -7.620
SSL -7.620
SSL -8.970
SSL -7.620
SSL -7.620
UP
RCB19
RC
B20
RCB21
RC
B22
RC BEAM SCHEDULE
BEAM REF. SIZE (mm) COMMENTS
RCB 1 350x800 DP -
RCB 2 350x800 DP -
RCB 3 300x1000 DP -
RCB 4 300x1225 DP -
RCB 5 300x300 DP -
RCB 6 300x300 DP -
RCB 7 300x300 DP -
RCB 8 300x1000 DP -
RCB 9 300x1225 DP -
RCB 10 300x300 DP -
RCB 11 300x300 DP -
RCB 12 300x300 DP -
RCB 13 300x300 DP -
RCB 14 300x300 DP *
RCB 15 200x300 DP -
RCB 16 200x300 DP -
RCB 17 200x300 DP -
RCB 18 200x300 DP -
RCB 19 300x300 DP -
RCB 20 200x300 DP -
RCB 21 300x300 DP -
RCB 22 200x300 DP -
DO NOT SCALE FROM THIS DRAWING
THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL SITEDIMENSIONS BEFORE COMMENCING ANY WORK
ALL DIMENSIONS IN mm UNLESS OTHERWISE NOTED ALL DIMENSIONS
AND LEVELS TO BE CONFIRMED
BY ARCHITECT SETTING OUT TO BE CONFIRMED ON SITE
FIDEL KARIM
STRUCTURAL
DRAWINGS
SCALEPAPER SIZEDATE
DRAWN CHECKED
DESCRIPTIONDATEREV
THIS DRAWING IS SUBJECT TO COPYRIGHT
-
--
04/08/2014
MIDDLE BASEMENT
LAYOUT
GA/02 P5
-
FK --
A1 1:50
P1 04/08/14 INITIAL ISSUEP2 03/12/14 REVISED AS CLOUDEDP3 06/07/15 GENERAL REVISIONP4 14/07/15 REVISED AS CLOUDEDP5 13/08/15 LIFT & WALL POSITIONS REVISED
KEY
NEW LOAD BEARING STUD PARTITION
NEW LOAD BEARING BRICKWORK
EXISTING WALL
NEW LOAD BEARING CONCRETE WALL
NEW NON-LOAD BEARING STUD WALL
NEW LOAD BEARING BLOCKWORK
NEW NON-LOAD BEARING BLOCKWORK
UP
3
S/03
6
S/01
1
S/01
2
S/02
4
S/04
SCALE 1:50
UPPER BASEMENT LAYOUT
SSL -4.320
SSL -4.320
SSL -4.320
SSL -4.320
WALL TIED
TO PILES
RC WALL
RC WALL
RC WALL
RC WALL
ALLOW 50% MAXIMUM CLEAR VOIDFOR SERVICES ( HIT & MISS)
ALLOW 50% MAXIMUM CLEAR VOIDFOR SERVICES ( HIT & MISS)
RCB13
RCB14
5
S/04 10
S/01
EXTEND SLAB TO FACE OF
PILES AND TIE IN
FOR LIGHTWELL STRATEGY
REFER TO GROUND FLOOR
PLANS
FOR LIGHTWELL STRATEGY
REFER TO GROUND FLOOR
PLANS
UP
RC
B15
RC
B16
RC
B17
RC
B18
12
D/01
UP
UP
RC BEAM SCHEDULE
BEAM REF. SIZE (mm) COMMENTS
RCB 1 350x800 DP -
RCB 2 350x800 DP -
RCB 3 300x1000 DP -
RCB 4 300x1225 DP -
RCB 5 300x300 DP -
RCB 6 300x300 DP -
RCB 7 300x300 DP -
RCB 8 300x1000 DP -
RCB 9 300x1225 DP -
RCB 10 300x300 DP -
RCB 11 300x300 DP -
RCB 12 300x300 DP -
RCB 13 300x300 DP -
RCB 14 300x300 DP *
RCB 15 200x300 DP -
RCB 16 200x300 DP -
RCB 17 200x300 DP -
RCB 18 200x300 DP -
RCB 19 300x300 DP -
RCB 20 200x300 DP -
RCB 21 300x300 DP -
RCB 22 200x300 DP -
DO NOT SCALE FROM THIS DRAWING
THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL SITEDIMENSIONS BEFORE COMMENCING ANY WORK
ALL DIMENSIONS IN mm UNLESS OTHERWISE NOTED ALL DIMENSIONS
AND LEVELS TO BE CONFIRMED
BY ARCHITECT SETTING OUT TO BE CONFIRMED ON SITE
FIDEL KARIM
STRUCTURAL
DRAWINGS
SCALEPAPER SIZEDATE
DRAWN CHECKED
DESCRIPTIONDATEREV
THIS DRAWING IS SUBJECT TO COPYRIGHT
-
--
04/08/2014
UPPER BASEMENT
LAYOUT
GA/03 P4
-
FK --
A1 1:50
P1 04/08/14 INITIAL ISSUEP2 03/12/14 REVISED AS CLOUDEDP3 06/07/15 GENERAL REVISIONSP4 14/07/15 REVISED WHERE CLOUDEDP4 13/08/15 LIFT & WALL POSITIONS REVISED
KEY
NEW LOAD BEARING STUD PARTITION
NEW LOAD BEARING BRICKWORK
EXISTING WALL
NEW LOAD BEARING CONCRETE WALL
NEW NON-LOAD BEARING STUD WALL
NEW LOAD BEARING BLOCKWORK
NEW NON-LOAD BEARING BLOCKWORK
UP
UP
6
S/01
1
S/01
2
S/02
3
S/03
SCALE 1:50
GROUND FLOOR LAYOUT
SSL -0.165
SSL -0.165
600x600 CAPPING BEAM
SSL -0.705
200 RC WALLUNDER
SSL -1.090
SSL -1.090
GLAZINGBY OTHERS
GLAZINGBY OTHERS
RC
B 1
200 RC WALLUNDER
ALLOW 50% MAXIMUM CLEAR VOIDFOR SERVICES ( HIT & MISS)
C5 C4
C3
C10
C8
C1
300 mmRC SLAB
ALLOW 50% MAXIMUM CLEAR VOIDFOR SERVICES ( HIT & MISS)
200 RC WALLUNDER
200 RC WALLUNDER
C2
C7
C6
C9
RC
B 2
RC
B 4
RCB 3 RC
B 5
RCB 7
RC
B 6
RC
B 9
RC
B10
RCB 8
RCB12
RC
B11
LIGHTWELL POSITION ON APPROVEDLAYOUT AND AS PREFERRED BYPLANNERS IN PRE-APPLICATION LETTER
LIGHTWELL POSITION ON APPROVEDLAYOUT AND AS PREFERRED BYPLANNERS IN PRE-APPLICATION LETTER
9
S/01
5
S/04
4
S/04
OPENING FOR FUTURE LIFT
OPENING FOR FUTURE LIFT
11
S/01
UP
VOID
VOID
SSL -0.705
UP
UP
UP
UP
STEEL BEAM SCHEDULE
BEAM REF. SIZE (mm) COMMENTS
B109 NOT USED -
B110 NOT USED -
B111 203 UC 46 -
B112 203 UC 46 -
B113 152 UC 30 -
B114 152 UC 30 -
B115 152 UC 30 -
B116 152 UC 30 -
B117 152 UC 30 -
B118 152 UC 30 -
B119 NOT USED -
B120 NOT USED -
B121 NOT USED -
B122 NOT USED -
B123 NOT USED -
B124 NOT USED -
B125 NOT USED -
B126 NOT USED -
RC BEAM SCHEDULE
BEAM REF. SIZE (mm) COMMENTS
RCB 1 350x800 DP -
RCB 2 350x800 DP -
RCB 3 300x1000 DP -
RCB 4 300x1225 DP -
RCB 5 300x300 DP -
RCB 6 300x300 DP -
RCB 7 300x300 DP -
RCB 8 300x1000 DP -
RCB 9 300x1225 DP -
RCB 10 300x300 DP -
RCB 11 300x300 DP -
RCB 12 300x300 DP -
RCB 13 300x300 DP -
RCB 14 300x300 DP *
RCB 15 200x300 DP -
RCB 16 200x300 DP -
RCB 17 200x300 DP -
RCB 18 200x300 DP -
RCB 19 300x300 DP -
RCB 20 200x300 DP -
RCB 21 300x300 DP -
RCB 22 200x300 DP -
STEEL COLUMN SCHEDULE
STEEL MARK SIZE (mm) COMMENTS
C1 70x70x6 SHS -
C2 70x70x6 SHS -
C3 70x70x6 SHS -
C4 70x70x6 SHS -
C5 70x70x6 SHS -
C6 70x70x6 SHS -
C7 70x70x6 SHS -
C8 70x70x6 SHS -
C9 70x70x6 SHS -
C10 70x70x6 SHS -
C11 NOT USED -
C12 NOT USED -
C13 NOT USED -
C14 NOT USED -
PADSTONE SCHEDULE
PADSTONEMARK
LENGTH WIDTH DEPTH
PS 220 100 100
PS1 220 100 100
PS2 220 100 100
DO NOT SCALE FROM THIS DRAWING
THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL SITEDIMENSIONS BEFORE COMMENCING ANY WORK
ALL DIMENSIONS IN mm UNLESS OTHERWISE NOTED ALL DIMENSIONS
AND LEVELS TO BE CONFIRMED
BY ARCHITECT SETTING OUT TO BE CONFIRMED ON SITE
FIDEL KARIM
STRUCTURAL
DRAWINGS
SCALEPAPER SIZEDATE
DRAWN CHECKED
DESCRIPTIONDATEREV
THIS DRAWING IS SUBJECT TO COPYRIGHT
-
--
04/08/2014
GROUND FLOOR
LAYOUT
GA/04 P6
-
FK --
A1 AS SHOWN
P1 04/08/14 INITIAL ISSUEP2 03/12/14 REVISED AS CLOUDEDP3 21/01/15 BEAMS ADDEDP4 06/07/15 GENERAL REVISONSP5 14/07/15 REVISED AS CLOUDEDP6 13/08/15 LIFT & WALL POSITIONS REVISED
KEY
NEW LOAD BEARING STUD PARTITION
NEW LOAD BEARING BRICKWORK
EXISTING WALL
NEW LOAD BEARING CONCRETE WALL
NEW NON-LOAD BEARING STUD WALL
NEW LOAD BEARING BLOCKWORK
NEW NON-LOAD BEARING BLOCKWORK
SCALE 1:50
FIRST FLOOR LAYOUT
B16
PS
PS
C3
FUTURE OPENINGFOR LIFT
B13B7
SP
RE
AD
ER
PSPS B12
B11 B14
B10
B6
C4UNDER
C5UNDER
B20
B3
PS PS
B4
PSPS
GLAZINGBY OTHERS
PS
SFL +2.280
B22
B21
PS
B25
B26
C10UNDER
B5
B28
B27
PS
C8
B42
B35
B30
SP
RE
AD
ER
B38
CRANKED STAIRCASEBEAMS TBC
PS
B39
B37
B40
C2UNDER
C1UNDER
C7UNDER
C6UNDER
C9UNDER
SERVICE VOID150x63 C16 TIMBERS@400 CRS
PS B18
B17B
19
B43
B15
B9
PS
B41
B36
B32
B31
B33
B34
150x63 C16 TIMBERS@400 CRS
B8
SP
RE
AD
ER
B44
B29
FUTURE OPENINGFOR LIFT
PS
PS
PSPS
PS
GLAZINGBY OTHERS
VOID
VOID
CRANKED STAIRCASEBEAMS TBC
PS
PSPS
PS
B11
2
SFL +2.280
SFL +2.280
SFL +2.280
SERVICE VOID
JULIET BALCONYBY SPECIALIST
LINTEL BEAM
JULIET BALCONYBY SPECIALIST
LINTEL BEAM
LINTEL BEAM
LINTEL BEAM
VOID
VOID
B??
UP
UP
UP
UP
PS
STEEL BEAM SCHEDULE
BEAM REF. SIZE (mm) COMMENTS
B1 NOT USED -
B2 NOT USED -
B3 152 UC 30 -
B4 152 UC 30 -
B5 203 UC 46 -
B6 203 UC 46 -
B7 125x65x15 PFC
B8 125x65x15 PFC
B9 100x50x10 PFC
B10 100x50x10 PFC
B11 100x50x10 PFC
B12 100x50x10 PFC
B13 152 UC 23 -
B14 100x50x10 PFC
B15 100x50x10 PFC
B16 126x65x15 PFC
B17 100x50x10 PFC
B18 100x50x10 PFC
B19 100x50x10 PFC
B20 152 UC 30 -
B21 125x65x15 PFC
B22 125x65x15 PFC
B23 NOT USED -
B24 NOT USED -
B25 152 UC 30 -
B26 203 UC 46 -
B27 203 UC 46 -
PADSTONE SCHEDULE
PADSTONEMARK
LENGTH WIDTH DEPTH
PS 220 100 100
PS1 220 100 100
PS2 220 100 100
STEEL COLUMN SCHEDULE
STEEL MARK SIZE (mm) COMMENTS
C1 70x70x6 SHS -
C2 70x70x6 SHS -
C3 70x70x6 SHS -
C4 70x70x6 SHS -
C5 70x70x6 SHS -
C6 70x70x6 SHS -
C7 70x70x6 SHS -
C8 70x70x6 SHS -
C9 70x70x6 SHS -
C10 70x70x6 SHS -
C11 NOT USED -
C12 NOT USED -
C13 NOT USED -
C14 NOT USED -
STEEL BEAM SCHEDULE
BEAM REF. SIZE (mm) COMMENTS
B28 152 UC 30 -
B29 125x65x15 PFC
B30 125x65x15 PFC
B31 100x50x10 PFC
B32 100x50x10 PFC
B33 100x50x10 PFC
B34 100x50x10 PFC
B35 152 UC 37 -
B36 100x50x10 PFC
B37 100x50x10 PFC
B38 152 UC 23 -
B39 100x50x10 PFC
B40 100x50x10 PFC
B41 100x50x10 PFC
B42 125x65x15 PFC
B43 125x65x15 PFC
B44 125x65x15 PFC
B45 152 UC 30 -
B46 100x50x10 PFC
B47 100x50x10 PFC
B48 152 UC 30 -
B49 152 UC 30 -
B50 100x50x10 PFC
B51 100x50x10 PFC
B52 152 UC 30 -
B53 203 UC 71 -
B54 100x50x10 PFC
STEEL BEAM SCHEDULE
BEAM REF. SIZE (mm) COMMENTS
B55 100x50x10 PFC
B56 100x50x10 PFC
B57 100x50x10 PFC
B58 100x50x10 PFC
B59 125x65x15 PFC
B60 100x50x10 PFC
B61 100x50x10 PFC
B62 152 UC 30 -
B63 152 UC 30 -
B64 152 UC 30 -
B65 100x50x10 PFC
B66 100x50x10 PFC
B67 152 UC 30 -
B68 152 UC 30 -
B69 100x50x10 PFC
B70 100x50x10 PFC
B71 152 UC 30 -
B72 203 UC 71 -
B73 125x65x15 PFC
B74 100x50x10 PFC
B75 100x50x10 PFC
B76 125x65x15 PFC
B77 100x50x10 PFC
B78 100x50x10 PFC
B79 100x50x10 PFC
B80 125x65x15 PFC
B81 152 UC 30 -
STEEL BEAM SCHEDULE
BEAM REF. SIZE (mm) COMMENTS
B82 152 UC 30 -
B83 100x50x10 PFC
B84 152 UC 37 -
B85 152 UC 37 -
B86 152 UC 37 -
B87 100x50x10 PFC
B88 152 UC 37 -
B89 152 UC 37 -
B90 152 UC 37 -
B91 152 UC 37 -
B92 152 UC 37 -
B93 152 UC 37 -
B94 152 UC 37 -
B95 152 UC 37 -
B96 152 UC 37 -
B97 100x50x10 PFC
B98 100x50x10 PFC
B99 100x50x10 PFC
B100 100x50x10 PFC
B101 100x50x10 PFC
B102 100x50x10 PFC
B103 100x50x10 PFC
B104 100x50x10 PFC
B105 100x50x10 PFC
B106 100x50x10 PFC
B107 100x50x10 PFC
B108 100x50x10 PFC
STEEL BEAM SCHEDULE
BEAM REF. SIZE (mm) COMMENTS
B109 NOT USED -
B110 NOT USED -
B111 203 UC 46 -
B112 203 UC 46 -
B113 152 UC 30 -
B114 152 UC 30 -
B115 152 UC 30 -
B116 152 UC 30 -
B117 152 UC 30 -
B118 152 UC 30 -
B119 NOT USED -
B120 NOT USED -
B121 NOT USED -
B122 NOT USED -
B123 NOT USED -
B124 NOT USED -
B125 NOT USED -
B126 NOT USED -
RC BEAM SCHEDULE
BEAM REF. SIZE (mm) COMMENTS
RCB 1 350x800 DP -
RCB 2 350x800 DP -
RCB 3 300x1000 DP -
RCB 4 300x1225 DP -
RCB 5 300x300 DP -
RCB 6 300x300 DP -
RCB 7 300x300 DP -
RCB 8 300x1000 DP -
RCB 9 300x1225 DP -
RCB 10 300x300 DP -
RCB 11 300x300 DP -
RCB 12 300x300 DP -
RCB 13 300x300 DP -
RCB 14 300x300 DP *
RCB 15 200x300 DP -
RCB 16 200x300 DP -
RCB 17 200x300 DP -
RCB 18 200x300 DP -
RCB 19 300x300 DP -
RCB 20 200x300 DP -
RCB 21 300x300 DP -
RCB 22 200x300 DP -
DO NOT SCALE FROM THIS DRAWING
THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL SITEDIMENSIONS BEFORE COMMENCING ANY WORK
ALL DIMENSIONS IN mm UNLESS OTHERWISE NOTED ALL DIMENSIONS
AND LEVELS TO BE CONFIRMED
BY ARCHITECT SETTING OUT TO BE CONFIRMED ON SITE
FIDEL KARIM
STRUCTURAL
DRAWINGS
SCALEPAPER SIZEDATE
DRAWN CHECKED
DESCRIPTIONDATEREV
THIS DRAWING IS SUBJECT TO COPYRIGHT
-
--
04/08/2014
FIRST FLOOR
LAYOUT
GA/05 P6
-
FK --
A1 AS SHOWN
P1 04/08/14 INITIAL ISSUEP2 03/12/14 REVISED AS CLOUDEDP3 21/01/15 SCHEDULES REVISEDP4 06/07/15 GENERAL REVISIONSP5 14/07/15 REVISED WHERE CLOUDEDP6 13/08/15 LIFT & WALL POSITIONS REVISED
KEY
NEW LOAD BEARING STUD PARTITION
NEW LOAD BEARING BRICKWORK
EXISTING WALL
NEW LOAD BEARING CONCRETE WALL
NEW NON-LOAD BEARING STUD WALL
NEW LOAD BEARING BLOCKWORK
NEW NON-LOAD BEARING BLOCKWORK
SCALE 1:50
SECOND FLOOR LAYOUT
UP
UP
UP
UP
C8UNDER
B81
B80
B76
B78
B75
B73
SP
RE
AD
ER
B54
SP
RE
AD
ER
B71
B52
B49
B68
B67
B64
B48
B45
B46
B47
B66
B65
B70
B69
B51
B50
B72
B53
C3UNDER
B62
B63
B59
PS PS PS PS
PS PS PS
PS PSPS PS
PS
PS
PS
B77
B79
B74
B57
B58
B60
B56
B61
B55
PSPSPS
PS PSPS
PS
B81
B82
PSPS
PS
PS
PS
PS
170x50 C16 TIMBERS@400 CRS
170x50 C16 TIMBERS@400 CRS
B97
LINTEL BEAM
LINTEL BEAM
LINTEL BEAM
SERVICES VOID
SERVICES VOID
CRANKED STAIRCASEBEAMS TBC
CRANKED STAIRCASEBEAMS TBC
STEEL BEAM SCHEDULE
BEAM REF. SIZE (mm) COMMENTS
B1 NOT USED -
B2 NOT USED -
B3 152 UC 30 -
B4 152 UC 30 -
B5 203 UC 46 -
B6 203 UC 46 -
B7 125x65x15 PFC
B8 125x65x15 PFC
B9 100x50x10 PFC
B10 100x50x10 PFC
B11 100x50x10 PFC
B12 100x50x10 PFC
B13 152 UC 23 -
B14 100x50x10 PFC
B15 100x50x10 PFC
B16 126x65x15 PFC
B17 100x50x10 PFC
B18 100x50x10 PFC
B19 100x50x10 PFC
B20 152 UC 30 -
B21 125x65x15 PFC
B22 125x65x15 PFC
B23 NOT USED -
B24 NOT USED -
B25 152 UC 30 -
B26 203 UC 46 -
B27 203 UC 46 -
PADSTONE SCHEDULE
PADSTONEMARK
LENGTH WIDTH DEPTH
PS 220 100 100
PS1 220 100 100
PS2 220 100 100
STEEL COLUMN SCHEDULE
STEEL MARK SIZE (mm) COMMENTS
C1 70x70x6 SHS -
C2 70x70x6 SHS -
C3 70x70x6 SHS -
C4 70x70x6 SHS -
C5 70x70x6 SHS -
C6 70x70x6 SHS -
C7 70x70x6 SHS -
C8 70x70x6 SHS -
C9 70x70x6 SHS -
C10 70x70x6 SHS -
C11 NOT USED -
C12 NOT USED -
C13 NOT USED -
C14 NOT USED -
STEEL BEAM SCHEDULE
BEAM REF. SIZE (mm) COMMENTS
B28 152 UC 30 -
B29 125x65x15 PFC
B30 125x65x15 PFC
B31 100x50x10 PFC
B32 100x50x10 PFC
B33 100x50x10 PFC
B34 100x50x10 PFC
B35 152 UC 37 -
B36 100x50x10 PFC
B37 100x50x10 PFC
B38 152 UC 23 -
B39 100x50x10 PFC
B40 100x50x10 PFC
B41 100x50x10 PFC
B42 125x65x15 PFC
B43 125x65x15 PFC
B44 125x65x15 PFC
B45 152 UC 30 -
B46 100x50x10 PFC
B47 100x50x10 PFC
B48 152 UC 30 -
B49 152 UC 30 -
B50 100x50x10 PFC
B51 100x50x10 PFC
B52 152 UC 30 -
B53 203 UC 71 -
B54 100x50x10 PFC
STEEL BEAM SCHEDULE
BEAM REF. SIZE (mm) COMMENTS
B55 100x50x10 PFC
B56 100x50x10 PFC
B57 100x50x10 PFC
B58 100x50x10 PFC
B59 125x65x15 PFC
B60 100x50x10 PFC
B61 100x50x10 PFC
B62 152 UC 30 -
B63 152 UC 30 -
B64 152 UC 30 -
B65 100x50x10 PFC
B66 100x50x10 PFC
B67 152 UC 30 -
B68 152 UC 30 -
B69 100x50x10 PFC
B70 100x50x10 PFC
B71 152 UC 30 -
B72 203 UC 71 -
B73 125x65x15 PFC
B74 100x50x10 PFC
B75 100x50x10 PFC
B76 125x65x15 PFC
B77 100x50x10 PFC
B78 100x50x10 PFC
B79 100x50x10 PFC
B80 125x65x15 PFC
B81 152 UC 30 -
STEEL BEAM SCHEDULE
BEAM REF. SIZE (mm) COMMENTS
B82 152 UC 30 -
B83 100x50x10 PFC
B84 152 UC 37 -
B85 152 UC 37 -
B86 152 UC 37 -
B87 100x50x10 PFC
B88 152 UC 37 -
B89 152 UC 37 -
B90 152 UC 37 -
B91 152 UC 37 -
B92 152 UC 37 -
B93 152 UC 37 -
B94 152 UC 37 -
B95 152 UC 37 -
B96 152 UC 37 -
B97 100x50x10 PFC
B98 100x50x10 PFC
B99 100x50x10 PFC
B100 100x50x10 PFC
B101 100x50x10 PFC
B102 100x50x10 PFC
B103 100x50x10 PFC
B104 100x50x10 PFC
B105 100x50x10 PFC
B106 100x50x10 PFC
B107 100x50x10 PFC
B108 100x50x10 PFC
STEEL BEAM SCHEDULE
BEAM REF. SIZE (mm) COMMENTS
B109 NOT USED -
B110 NOT USED -
B111 203 UC 46 -
B112 203 UC 46 -
B113 152 UC 30 -
B114 152 UC 30 -
B115 152 UC 30 -
B116 152 UC 30 -
B117 152 UC 30 -
B118 152 UC 30 -
B119 NOT USED -
B120 NOT USED -
B121 NOT USED -
B122 NOT USED -
B123 NOT USED -
B124 NOT USED -
B125 NOT USED -
B126 NOT USED -
RC BEAM SCHEDULE
BEAM REF. SIZE (mm) COMMENTS
RCB 1 350x800 DP -
RCB 2 350x800 DP -
RCB 3 300x1000 DP -
RCB 4 300x1225 DP -
RCB 5 300x300 DP -
RCB 6 300x300 DP -
RCB 7 300x300 DP -
RCB 8 300x1000 DP -
RCB 9 300x1225 DP -
RCB 10 300x300 DP -
RCB 11 300x300 DP -
RCB 12 300x300 DP -
RCB 13 300x300 DP -
RCB 14 300x300 DP *
RCB 15 200x300 DP -
RCB 16 200x300 DP -
DO NOT SCALE FROM THIS DRAWING
THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL SITEDIMENSIONS BEFORE COMMENCING ANY WORK
ALL DIMENSIONS IN mm UNLESS OTHERWISE NOTED ALL DIMENSIONS
AND LEVELS TO BE CONFIRMED
BY ARCHITECT SETTING OUT TO BE CONFIRMED ON SITE
FIDEL KARIM
STRUCTURAL
DRAWINGS
SCALEPAPER SIZEDATE
DRAWN CHECKED
DESCRIPTIONDATEREV
THIS DRAWING IS SUBJECT TO COPYRIGHT
-
--
04/08/2014
SECOND FLOOR
LAYOUT
GA/06 P3
-
FK --
A1 AS SHOWN
P1 04/08/14 INITIAL ISSUEP2 03/12/14 REVISED AS CLOUDEDP3 06/07/15 GENERAL REVISIONS
KEY
NEW LOAD BEARING STUD PARTITION
NEW LOAD BEARING BRICKWORK
EXISTING WALL
NEW LOAD BEARING CONCRETE WALL
NEW NON-LOAD BEARING STUD WALL
NEW LOAD BEARING BLOCKWORK
NEW NON-LOAD BEARING BLOCKWORK
SCALE 1:50
THIRD FLOOR LAYOUT
UP
UP
B101
B83
PS
PS
B87
PS
B84
PS
PS
PS2
PS
B86
PS
PS
B90
PS
PS
B88
100x50x10 PFC@400 CRS
100x50x10 PFC@400 CRS
100x50x10 PFC@400 CRS
100x50x10 PFC@400 CRS
B99
B10
0B97
B108
B98
B10
2
B104
B105
B10
3 B10
6 B10
7
PS1
CRANKED STAIRCASEBEAMS TBC
CRANKED STAIRCASEBEAMS TBC
STEEL BEAM SCHEDULE
BEAM REF. SIZE (mm) COMMENTS
B1 NOT USED -
B2 NOT USED -
B3 152 UC 30 -
B4 152 UC 30 -
B5 203 UC 46 -
B6 203 UC 46 -
B7 125x65x15 PFC
B8 125x65x15 PFC
B9 100x50x10 PFC
B10 100x50x10 PFC
B11 100x50x10 PFC
B12 100x50x10 PFC
B13 152 UC 23 -
B14 100x50x10 PFC
B15 100x50x10 PFC
B16 126x65x15 PFC
B17 100x50x10 PFC
B18 100x50x10 PFC
B19 100x50x10 PFC
B20 152 UC 30 -
B21 125x65x15 PFC
B22 125x65x15 PFC
B23 NOT USED -
B24 NOT USED -
B25 152 UC 30 -
B26 203 UC 46 -
B27 203 UC 46 -
PADSTONE SCHEDULE
PADSTONEMARK
LENGTH WIDTH DEPTH
PS 220 100 100
PS1 220 100 100
PS2 220 100 100
STEEL COLUMN SCHEDULE
STEEL MARK SIZE (mm) COMMENTS
C1 70x70x6 SHS -
C2 70x70x6 SHS -
C3 70x70x6 SHS -
C4 70x70x6 SHS -
C5 70x70x6 SHS -
C6 70x70x6 SHS -
C7 70x70x6 SHS -
C8 70x70x6 SHS -
C9 70x70x6 SHS -
C10 70x70x6 SHS -
C11 NOT USED -
C12 NOT USED -
C13 NOT USED -
C14 NOT USED -
STEEL BEAM SCHEDULE
BEAM REF. SIZE (mm) COMMENTS
B28 152 UC 30 -
B29 125x65x15 PFC
B30 125x65x15 PFC
B31 100x50x10 PFC
B32 100x50x10 PFC
B33 100x50x10 PFC
B34 100x50x10 PFC
B35 152 UC 37 -
B36 100x50x10 PFC
B37 100x50x10 PFC
B38 152 UC 23 -
B39 100x50x10 PFC
B40 100x50x10 PFC
B41 100x50x10 PFC
B42 125x65x15 PFC
B43 125x65x15 PFC
B44 125x65x15 PFC
B45 152 UC 30 -
B46 100x50x10 PFC
B47 100x50x10 PFC
B48 152 UC 30 -
B49 152 UC 30 -
B50 100x50x10 PFC
B51 100x50x10 PFC
B52 152 UC 30 -
B53 203 UC 71 -
B54 100x50x10 PFC
STEEL BEAM SCHEDULE
BEAM REF. SIZE (mm) COMMENTS
B55 100x50x10 PFC
B56 100x50x10 PFC
B57 100x50x10 PFC
B58 100x50x10 PFC
B59 125x65x15 PFC
B60 100x50x10 PFC
B61 100x50x10 PFC
B62 152 UC 30 -
B63 152 UC 30 -
B64 152 UC 30 -
B65 100x50x10 PFC
B66 100x50x10 PFC
B67 152 UC 30 -
B68 152 UC 30 -
B69 100x50x10 PFC
B70 100x50x10 PFC
B71 152 UC 30 -
B72 203 UC 71 -
B73 125x65x15 PFC
B74 100x50x10 PFC
B75 100x50x10 PFC
B76 125x65x15 PFC
B77 100x50x10 PFC
B78 100x50x10 PFC
B79 100x50x10 PFC
B80 125x65x15 PFC
B81 152 UC 30 -
STEEL BEAM SCHEDULE
BEAM REF. SIZE (mm) COMMENTS
B82 152 UC 30 -
B83 100x50x10 PFC
B84 152 UC 37 -
B85 152 UC 37 -
B86 152 UC 37 -
B87 100x50x10 PFC
B88 152 UC 37 -
B89 152 UC 37 -
B90 152 UC 37 -
B91 152 UC 37 -
B92 152 UC 37 -
B93 152 UC 37 -
B94 152 UC 37 -
B95 152 UC 37 -
B96 152 UC 37 -
B97 100x50x10 PFC
B98 100x50x10 PFC
B99 100x50x10 PFC
B100 100x50x10 PFC
B101 100x50x10 PFC
B102 100x50x10 PFC
B103 100x50x10 PFC
B104 100x50x10 PFC
B105 100x50x10 PFC
B106 100x50x10 PFC
B107 100x50x10 PFC
B108 100x50x10 PFC
STEEL BEAM SCHEDULE
BEAM REF. SIZE (mm) COMMENTS
B109 NOT USED -
B110 NOT USED -
B111 203 UC 46 -
B112 203 UC 46 -
B113 152 UC 30 -
B114 152 UC 30 -
B115 152 UC 30 -
B116 152 UC 30 -
B117 152 UC 30 -
B118 152 UC 30 -
B119 NOT USED -
B120 NOT USED -
B121 NOT USED -
B122 NOT USED -
B123 NOT USED -
B124 NOT USED -
B125 NOT USED -
B126 NOT USED -
RC BEAM SCHEDULE
BEAM REF. SIZE (mm) COMMENTS
RCB 1 350x800 DP -
RCB 2 350x800 DP -
RCB 3 300x1000 DP -
RCB 4 300x1225 DP -
RCB 5 300x300 DP -
RCB 6 300x300 DP -
RCB 7 300x300 DP -
RCB 8 300x1000 DP -
RCB 9 300x1225 DP -
RCB 10 300x300 DP -
RCB 11 300x300 DP -
RCB 12 300x300 DP -
RCB 13 300x300 DP -
RCB 14 300x300 DP *
RCB 15 200x300 DP -
RCB 16 200x300 DP -
DO NOT SCALE FROM THIS DRAWING
THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL SITEDIMENSIONS BEFORE COMMENCING ANY WORK
ALL DIMENSIONS IN mm UNLESS OTHERWISE NOTED ALL DIMENSIONS
AND LEVELS TO BE CONFIRMED
BY ARCHITECT SETTING OUT TO BE CONFIRMED ON SITE
FIDEL KARIM
STRUCTURAL
DRAWINGS
SCALEPAPER SIZEDATE
DRAWN CHECKED
DESCRIPTIONDATEREV
THIS DRAWING IS SUBJECT TO COPYRIGHT
-
--
04/08/2014
THIRD FLOOR
LAYOUT
GA/07 P3
-
FK --
A1 AS SHOWN
P1 04/08/14 INITIAL ISSUEP2 03/12/14 REVISED AS CLOUDEDP3 06/07/15 GENERAL REVISIONS
KEY
NEW LOAD BEARING STUD PARTITION
NEW LOAD BEARING BRICKWORK
EXISTING WALL
NEW LOAD BEARING CONCRETE WALL
NEW NON-LOAD BEARING STUD WALL
NEW LOAD BEARING BLOCKWORK
NEW NON-LOAD BEARING BLOCKWORK
SCALE 1:50
ROOF LAYOUTB
85
PS
B93
PS
PS
PS
B89
PS
B95
PS
PS
PS
B92
PS
B96
PS
PS
PS
B91
B94
150x50 C16@400 CRS
150x50 C16@400 CRS
150x50 C16@400 CRS
150x50 C16@400 CRS
PS
PS
PS
PS
STEEL BEAM SCHEDULE
BEAM REF. SIZE (mm) COMMENTS
B1 NOT USED -
B2 NOT USED -
B3 152 UC 30 -
B4 152 UC 30 -
B5 203 UC 46 -
B6 203 UC 46 -
B7 125x65x15 PFC
B8 125x65x15 PFC
B9 100x50x10 PFC
B10 100x50x10 PFC
B11 100x50x10 PFC
B12 100x50x10 PFC
B13 152 UC 23 -
B14 100x50x10 PFC
B15 100x50x10 PFC
B16 126x65x15 PFC
B17 100x50x10 PFC
B18 100x50x10 PFC
B19 100x50x10 PFC
B20 152 UC 30 -
B21 125x65x15 PFC
B22 125x65x15 PFC
B23 NOT USED -
B24 NOT USED -
B25 152 UC 30 -
B26 203 UC 46 -
B27 203 UC 46 -
PADSTONE SCHEDULE
PADSTONEMARK
LENGTH WIDTH DEPTH
PS 220 100 100
PS1 220 100 100
PS2 220 100 100
STEEL COLUMN SCHEDULE
STEEL MARK SIZE (mm) COMMENTS
C1 70x70x6 SHS -
C2 70x70x6 SHS -
C3 70x70x6 SHS -
C4 70x70x6 SHS -
C5 70x70x6 SHS -
C6 70x70x6 SHS -
C7 70x70x6 SHS -
C8 70x70x6 SHS -
C9 70x70x6 SHS -
C10 70x70x6 SHS -
C11 NOT USED -
C12 NOT USED -
C13 NOT USED -
C14 NOT USED -
STEEL BEAM SCHEDULE
BEAM REF. SIZE (mm) COMMENTS
B28 152 UC 30 -
B29 125x65x15 PFC
B30 125x65x15 PFC
B31 100x50x10 PFC
B32 100x50x10 PFC
B33 100x50x10 PFC
B34 100x50x10 PFC
B35 152 UC 37 -
B36 100x50x10 PFC
B37 100x50x10 PFC
B38 152 UC 23 -
B39 100x50x10 PFC
B40 100x50x10 PFC
B41 100x50x10 PFC
B42 125x65x15 PFC
B43 125x65x15 PFC
B44 125x65x15 PFC
B45 152 UC 30 -
B46 100x50x10 PFC
B47 100x50x10 PFC
B48 152 UC 30 -
B49 152 UC 30 -
B50 100x50x10 PFC
B51 100x50x10 PFC
B52 152 UC 30 -
B53 203 UC 71 -
B54 100x50x10 PFC
STEEL BEAM SCHEDULE
BEAM REF. SIZE (mm) COMMENTS
B55 100x50x10 PFC
B56 100x50x10 PFC
B57 100x50x10 PFC
B58 100x50x10 PFC
B59 125x65x15 PFC
B60 100x50x10 PFC
B61 100x50x10 PFC
B62 152 UC 30 -
B63 152 UC 30 -
B64 152 UC 30 -
B65 100x50x10 PFC
B66 100x50x10 PFC
B67 152 UC 30 -
B68 152 UC 30 -
B69 100x50x10 PFC
B70 100x50x10 PFC
B71 152 UC 30 -
B72 203 UC 71 -
B73 125x65x15 PFC
B74 100x50x10 PFC
B75 100x50x10 PFC
B76 125x65x15 PFC
B77 100x50x10 PFC
B78 100x50x10 PFC
B79 100x50x10 PFC
B80 125x65x15 PFC
B81 152 UC 30 -
STEEL BEAM SCHEDULE
BEAM REF. SIZE (mm) COMMENTS
B82 152 UC 30 -
B83 100x50x10 PFC
B84 152 UC 37 -
B85 152 UC 37 -
B86 152 UC 37 -
B87 100x50x10 PFC
B88 152 UC 37 -
B89 152 UC 37 -
B90 152 UC 37 -
B91 152 UC 37 -
B92 152 UC 37 -
B93 152 UC 37 -
B94 152 UC 37 -
B95 152 UC 37 -
B96 152 UC 37 -
B97 100x50x10 PFC
B98 100x50x10 PFC
B99 100x50x10 PFC
B100 100x50x10 PFC
B101 100x50x10 PFC
B102 100x50x10 PFC
B103 100x50x10 PFC
B104 100x50x10 PFC
B105 100x50x10 PFC
B106 100x50x10 PFC
B107 100x50x10 PFC
B108 100x50x10 PFC
STEEL BEAM SCHEDULE
BEAM REF. SIZE (mm) COMMENTS
B109 NOT USED -
B110 NOT USED -
B111 203 UC 46 -
B112 203 UC 46 -
B113 152 UC 30 -
B114 152 UC 30 -
B115 152 UC 30 -
B116 152 UC 30 -
B117 152 UC 30 -
B118 152 UC 30 -
B119 NOT USED -
B120 NOT USED -
B121 NOT USED -
B122 NOT USED -
B123 NOT USED -
B124 NOT USED -
B125 NOT USED -
B126 NOT USED -
RC BEAM SCHEDULE
BEAM REF. SIZE (mm) COMMENTS
RCB 1 350x800 DP -
RCB 2 350x800 DP -
RCB 3 300x1000 DP -
RCB 4 300x1225 DP -
RCB 5 300x300 DP -
RCB 6 300x300 DP -
RCB 7 300x300 DP -
RCB 8 300x1000 DP -
RCB 9 300x1225 DP -
RCB 10 300x300 DP -
RCB 11 300x300 DP -
RCB 12 300x300 DP -
RCB 13 300x300 DP -
RCB 14 300x300 DP *
RCB 15 200x300 DP -
RCB 16 200x300 DP -
DO NOT SCALE FROM THIS DRAWING
THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL SITEDIMENSIONS BEFORE COMMENCING ANY WORK
ALL DIMENSIONS IN mm UNLESS OTHERWISE NOTED ALL DIMENSIONS
AND LEVELS TO BE CONFIRMED
BY ARCHITECT SETTING OUT TO BE CONFIRMED ON SITE
FIDEL KARIM
STRUCTURAL
DRAWINGS
SCALEPAPER SIZEDATE
DRAWN CHECKED
DESCRIPTIONDATEREV
THIS DRAWING IS SUBJECT TO COPYRIGHT
-
--
04/08/2014
ROOF LAYOUT
GA/08 P4
-
FK --
A1 AS SHOWN
P1 04/08/14 INITIAL ISSUEP2 03/12/14 REVISED AS CLOUDEDP3 21/01/15 PADSTONES REVISEDP4 06/07/15 GENERAL REVISIONS
KEY
NEW LOAD BEARING STUD PARTITION
NEW LOAD BEARING BRICKWORK
EXISTING WALL
NEW LOAD BEARING CONCRETE WALL
NEW NON-LOAD BEARING STUD WALL
NEW LOAD BEARING BLOCKWORK
NEW NON-LOAD BEARING BLOCKWORK
GA01
SECTION 1-1SCALE 1:25
EXISTING FOOTINGTRIMMED BACK
2 LAYERS 1200g VISQUEENSLIP MEMBRANE
CELLCORE HEAVE PROTECTIONTO U/S SLABS BEAMS
RC SLAB
3:1 SHARP SAND :CEMENT MIX. ENSURE
DRY PACK IS WELLRAMMED IN WITH ALL
VOIDS FILLED
No. 35FFL TBCGROUND FLOOR
SSL -0.165
CAVITY BLOCKWORKOMITTED FOR CLARITY
RC WALL
RC WALL
MASS CONCRETEUNDERPIN TO
EXISTING FOOTING
RC SLAB
RC SLAB
RC SLAB
UPPER BASEMENTSSL -4.320
LOWER BASEMENTSSL -10.345
MIDDLE BASEMENTSSL -7.620
BORED RC PILE
RC GROUND BEAM750x600 DEEP
EDGE BEAM
EDGE BEAM
EDGE BEAM
BORED RC PILE
PILE CAP
RC WALL
RC WALL
RC WALL
STAIRWELL
BOREHOLE AND LINER FOR LIFTHYDRAULIC PISTON INDICATIVE ONLYDETAILS TBC
GA01
SECTION 6-6 SIMILAR - OPP. HANDSCALE 1:25
BORED RC PILE
2 SKINS 100BLOCKWORK DO NOT SCALE FROM THIS DRAWING
THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL SITEDIMENSIONS BEFORE COMMENCING ANY WORK
ALL DIMENSIONS IN mm UNLESS OTHERWISE NOTED ALL DIMENSIONS
AND LEVELS TO BE CONFIRMED
BY ARCHITECT SETTING OUT TO BE CONFIRMED ON SITE
FIDEL KARIM
STRUCTURAL
DRAWINGS
SCALEPAPER SIZEDATE
DRAWN CHECKED
DESCRIPTIONDATEREV
THIS DRAWING IS SUBJECT TO COPYRIGHT
-
--
04/08/2014
SECTIONS THROUGH
BUILDING
S/01 P6
-
AD --
A1 AS SHOWN
P1 04/08/14 INITIAL ISSUEP2 03/12/14 REVISED AS CLOUDEDP3 21/01/15 MASS CONCRETE WALL REVISEDP4 06/07/15 REVISED AS CLOUDEDP5 14/07/15 REVISED WHERE CLOUDEDP6 12/08/15 REVISED WHERE CLOUDED
GA01
SECTION 2-2SCALE 1:25
CELLCORE HEAVE PROTECTIONTO U/S SLABS BEAMS
BORED RC PILES
BORED RC PILES
MASS CONCRETEUNDERPIN TOEXISTING FOOTING
EXISTING MASONRYBOUNDARY WALL
RC SLAB
RC WALL
RC WALL
3:1 SHARP SAND :CEMENT MIX. ENSURE
DRY PACK IS WELLRAMMED IN WITH ALL
VOIDS FILLED
MASS CONCRETEUNDERPIN TO
EXISTING FOOTING
LOWER BASEMENTSSL -10.345
GLAZED FLOOR
UPPER BASEMENTSSL -4.320 RC SLAB
RC SLAB
RC GROUND BEAM750x600 DEEP
RC SLAB
EXISTING CONCRETETRIMMED BACK
3:1 SHARP SAND :CEMENT MIX. ENSUREDRY PACK IS WELLRAMMED IN WITH ALLVOIDS FILLED
RC SLAB
EXISTING CONCRETE
GROUND FLOORSSL -1.090
MIDDLE BASEMENTSSL -7.620
RC SLAB
GLAZED FLOORPUBLIC HOUSEEXTENSION
EXISTING BASEMENTTBC
CAVITY BLOCKWORKOMITTED FOR CLARITY
CAVITY BLOCKWORKOMITTED FOR CLARITY
RC SLAB
RC WALL
SSL - 8.627
SSL -8.970
BORED RC PILES
RC GROUND BEAM750x600 DEEP
RC GROUND BEAM750x600 DEEP
RC SLAB
NOTE: BACK FILLING OF GARDEN IS TO BECARRIED OUT SO THAT DIFERENCE IN LEVELSIS NO MORE THAN 200mm ON EACH SIDE
2 LAYERS 1200g VISQUEENSLIP MEMBRANE
2 LAYERS 1200g VISQUEENSLIP MEMBRANE
2 SKINS 100BLOCKWORK
GROUND FLOORSSL -1.090
T.O. UPSTANDSSL -0.390
T.O. UPSTANDSSL -0.000
EXISTING MASONRYBOUNDARY WALL
VOID
DO NOT SCALE FROM THIS DRAWING
THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL SITEDIMENSIONS BEFORE COMMENCING ANY WORK
ALL DIMENSIONS IN mm UNLESS OTHERWISE NOTED ALL DIMENSIONS
AND LEVELS TO BE CONFIRMED
BY ARCHITECT SETTING OUT TO BE CONFIRMED ON SITE
FIDEL KARIM
STRUCTURAL
DRAWINGS
SCALEPAPER SIZEDATE
DRAWN CHECKED
DESCRIPTIONDATEREV
THIS DRAWING IS SUBJECT TO COPYRIGHT
-
--
04/08/2014
SECTIONS THROUGH
BUILDING
S/02 P3
-
AD --
A1 AS SHOWN
P1 04/08/14 INITIAL ISSUEP2 03/12/14 REVISED AS CLOUDEDP3 06/07/15 REVISED AS CLOUDED
GA01
SECTION 3-3SCALE 1:25
EXISTING FOOTINGTRIMMED BACK
MASS CONCRETEUNDERPIN TO
EXISTING FOOTING
EXISTING FOOTINGTRIMMED BACK
BORED RC PILES
MASS CONCRETEUNDERPIN TOEXISTING FOOTING
NEW SINGLE SKIN BLOCKWORKCRAMPED TO EXISTING WALL
NEW SINGLE SKIN BLOCKWORKCRAMPED TO EXISTING WALL
CELLCORE HEAVE PROTECTIONTO U/S SLABS BEAMS
EXISTING CONCRETE
3:1 SHARP SAND :CEMENT MIX. ENSURE
DRY PACK IS WELLRAMMED IN WITH ALL
VOIDS FILLED
RC WALL
RC WALL
No. 35FFL TBC
RC SLAB
RC SLAB
PUBLIC HOUSEREAR EXTENSION
RC SLAB
3:1 SHARP SAND :CEMENT MIX. ENSUREDRY PACK IS WELLRAMMED IN WITH ALLVOIDS FILLED
GROUND FLOORSSL -0.705
RC SLAB
CAVITY BLOCKWORKOMITTED FOR CLARITY
CAVITY BLOCKWORKOMITTED FOR CLARITY
RC SLAB
RC GROUND BEAM750x600 DEEP
BORED RC PILES
LOWER BASEMENTSSL -10.345
UPPER BASEMENTSSL -4.320
MIDDLE BASEMENTSSL -7.620
GROUND FLOORSSL -0.465
BORED RC PILES
RC GROUND BEAM750x600 DEEP
SSL -8.970
SSL - 8.627
RC SLAB
RC GROUND BEAM750x600 DEEP
2 SKINS 100BLOCKWORK
2 LAYERS 1200g VISQUEENSLIP MEMBRANE
DO NOT SCALE FROM THIS DRAWING
THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL SITEDIMENSIONS BEFORE COMMENCING ANY WORK
ALL DIMENSIONS IN mm UNLESS OTHERWISE NOTED ALL DIMENSIONS
AND LEVELS TO BE CONFIRMED
BY ARCHITECT SETTING OUT TO BE CONFIRMED ON SITE
FIDEL KARIM
STRUCTURAL
DRAWINGS
SCALEPAPER SIZEDATE
DRAWN CHECKED
DESCRIPTIONDATEREV
THIS DRAWING IS SUBJECT TO COPYRIGHT
-
--
04/08/2014
SECTIONS THROUGH
BUILDING
S/03 P5
-
AD --
A1 AS SHOWN
P1 04/08/14 INITIAL ISSUEP2 03/12/14 REVISED AS CLOUDEDP3 21/01/15 MASS CONCRETE WALL REVISEDP4 06/07/15 REVISED AS CLOUDEDP5 14/07/15 REVISED AS CLOUDED
MASS CONCRETEUNDERPIN TO
EXISTING FOOTING
EXISTING FOOTINGTRIMMED BACK
EXISTING MASS CONCRETETO BE BROKEN OUT
EXISTING BOUNDARY WALL (TOREMAIN IN PLACE & BE PROPPED
IN TEMPORARY CONDITIONS)
BORED RC PILES
CELLCORE HEAVE PROTECTIONTO U/S SLABS BEAMS
RC SLAB
GA01
SECTION 4-4SCALE 1:25
RC SLAB
RC GROUND BEAM750x600 DEEP
RC SLAB
200mmRC WALL
LOWER BASEMENTSSL -10.795
RC SLAB
3:1 SHARP SAND : CEMENT MIX.ENSURE DRY PACK IS WELL
RAMMED IN WITH ALL VOIDS FILLED
NEW BLOCKWORK WALLFIXED TO EXISTING WALL
UPPER BASEMENTSSL -4.320
SSL -8.970
GROUND FLOORSSL -0.705
STAIRWELL
GA01
SECTION 5-5 SIMILARSCALE 1:25
2 LAYERS 1200g VISQUEENSLIP MEMBRANE
MIDDLE BASEMENTSSL -7.620
LOWER BASEMENTSSL -10.345
GA01
SECTION 7-7SCALE 1:25
BOREHOLE FOR LIFT RAMSSL -14.465
RC SLAB
RC WALL
STAIRWELL STAIRWELL
MIDDLE BASEMENTSSL -7.620
LOWER BASEMENTSSL -10.345
GA01
SECTION 8-8 SIMILARSCALE 1:25
RC WALL
RC WALLRC WALL
DO NOT SCALE FROM THIS DRAWING
THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL SITEDIMENSIONS BEFORE COMMENCING ANY WORK
ALL DIMENSIONS IN mm UNLESS OTHERWISE NOTED ALL DIMENSIONS
AND LEVELS TO BE CONFIRMED
BY ARCHITECT SETTING OUT TO BE CONFIRMED ON SITE
FIDEL KARIM
STRUCTURAL
DRAWINGS
SCALEPAPER SIZEDATE
DRAWN CHECKED
DESCRIPTIONDATEREV
THIS DRAWING IS SUBJECT TO COPYRIGHT
-
--
28/11/2014
SECTIONS THROUGH
BUILDING
S/04 P5
-
KIB --
A1 AS SHOWN
P1 28/11/14 INITIAL ISSUEP2 03/12/14 REVISED AS CLOUDEDP3 21/01/15 MASS CONCRETE WALL REVISEDP4 06/07/15 REVISED AS CLOUDEDP5 14/07/15 REVISED AS CLOUDED
DO NOT SCALE FROM THIS DRAWING
THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL SITEDIMENSIONS BEFORE COMMENCING ANY WORK
ALL DIMENSIONS IN mm UNLESS OTHERWISE NOTED ALL DIMENSIONS
AND LEVELS TO BE CONFIRMED
BY ARCHITECT SETTING OUT TO BE CONFIRMED ON SITE
FIDEL KARIM
STRUCTURAL
DRAWINGS
SCALEPAPER SIZEDATE
DRAWN CHECKED
DESCRIPTIONDATEREV
THIS DRAWING IS SUBJECT TO COPYRIGHT
-
--
04/08/2014
STRUCTURAL
DETAILS & SECTIONS
D/01 P1
-
KIB --
A1 AS SHOWN
P1 13/08/15 INITIAL ISSUE
RC ELEMENTS - ALL C35 CONCRETEFOR TENDER PURPOSES THE FOLLOWING REINFORCEMENT RATES ARE TO BE USED
ELEMENT WIDTH/THICKNESS REINFORCEMENT ( kg / m ³ )
BASEMENT SLAB 450 140
GROUND AND INTERMEDIATE SLABS VARIOUS 180
POOL WALLS 200 100
CENTRAL RC WALL 200 100
PERIMETER RC WALL 300 95
PERIMETER RC WALL 450 160
RC BEAMS VARIOUS 200
DO NOT SCALE FROM THIS DRAWING
THE CONTRACTOR IS RESPONSIBLE FOR VERIFYING ALL SITEDIMENSIONS BEFORE COMMENCING ANY WORK
ALL DIMENSIONS IN mm UNLESS OTHERWISE NOTED ALL DIMENSIONS
AND LEVELS TO BE CONFIRMED
BY ARCHITECT SETTING OUT TO BE CONFIRMED ON SITE
FIDEL KARIM
STRUCTURAL
DRAWINGS
SCALEPAPER SIZEDATE
DRAWN CHECKED
DESCRIPTIONDATEREV
THIS DRAWING IS SUBJECT TO COPYRIGHT
-
--
17/04/2014
GENERAL NOTES
N/01 P3
-
AD --
A1
P1 17/04/14 INITIAL ISSUEP2 03/12/14 REVISED AS CLOUDEDP3 21/01/15
GENERAL NOTES:
1. ALL DRAWINGS ARE TO BE READ IN CONJUNCTION WITH THE SPECIFICATION & ALL RELEVANT ENGINEER'S AND ARCHITECTSDRAWINGS. IF ANY CONFLICT ARISES BETWEEN DOCUMENTATION INFORM THE DESIGN TEAM IMMEDIATELY.
2. DO NOT SCALE THE DRAWINGS. WORK TO FIGURED DIMENSIONS ONLY.
3, ALL SETTING OUT TO ARCHITECTS DRAWINGS
4. THE ENGINEER IS TO BE INFORMED IF ANY DETAIL INDICATED OR IMPLIED ON THIS DRAWING CANNOT BE MAINTAINED IN GOOD TIMESO THAT ALTERNATIVE SOLUTIONS MAY BE MADE AVAILABLE.
5. THE CONTRACTOR IS TO TAKE ALL NECESSARY PRECAUTIONS TO MAINTAIN THE STABILITY OF THE EXISTING AND ADJACENTSTRUCTURES AT ALL TIMES DURING THE COURSE OF THE WORKS.THE CONTRACTOR IS RESPONSIBLE FOR THE DESIGN OF ALL TEMPORARY WORKS AND IS TO SUBMIT DETAILS, CALCULATIONS ANDMETHOD STATEMENTS TO THE STRUCTURAL ENGINEER FOR APPRAISAL PRIOR TO THE COMMENCEMENT OF WORKS.
STRUCTURAL STEELWORK NOTES
1. ALL MATERIALS, FABRICATION, WORKMANSHIP AND ERECTION OF STEELWORK SHALL BE IN ACCORDANCE WITH THE CURRENTEDITION OF THE NATIONAL STEELWORK SPECIFICATION FOR BUILDING CONSTRUCTION AS PUBLISHED BY THE BRITISHCONSTRUCTIONAL STEELWORK ASSOCIATION.
2. ALL STEELWORK TO BE GRADE S355(50) TO BS 4360:1986
3. ALL STEELWORK CONNECTIONS TO BE DESIGNED BY THE STEELWORK FABRICATOR FOR LOADS AS SPECIFIED ON THE DRAWINGS.
4. ALL FORCES AND MOMENTS ARE GIVEN AT ULTIMATE LIMIT STATE (ULS) FACTORED LOADS TO BS 5950 IN KILONEWTONS (KN).BENDING MOMENTS ARE IN KILONEWTONMETRES (KNM) AND ARE SHOWN IN BRACKETS.
5. ALL FABRICATION DRAWINGS AND DESIGN CALCULATIONS ARE TO BE SUBMITTED TO THE STRUCTURAL ENGINEER FOR APPROVALAT LEAST TWO WEEKS PRIOR TO THE COMMENCEMENT OF FABRICATION.
6. STEEL BEAMS SHALL AT LEAST HAVE THE MINIMUM BEARINGS ON SUPPORTING WALLS AS SHOWN ON THE DRAWINGS. WHERE NODETAILS OF BEARINGS ARE SHOWN PROVIDE BEARINGS TO THE FULL WIDTH OF THE SUPPORTING LEAF,PADSTONE OR 150mmWHICHEVER IS GREATER.
7. ALL STEEL BEAMS TO HAVE 6mm STIFFENER PLATES TO BOTH SIDES OF BEAM BETWEEN FLANGES AT ALL BEARING POSITIONSUNLESS OTHERWISE NOTED.. STIFFENER PLATES TO BE WELDED TO BEAMS WITH 6mm FULL PROFILE FILLET WELDS.
8. SITE MODIFICATIONS TO STRUCTURAL STEELWORK SHALL NOT BE CARRIED OUT UNLESS PRIOR APPROVAL HAS BEEN OFKAINEDFROM THE ENGINEER
9. ALL STRUCTURAL STEELWORK SHALL BE BLAST CLEANED TO B.S.7079 : PART A1, PREPARATION GRADE SA21/2 AND, EXCEPT WHERESPECIFIED AS GALVANISED, SHALL BE PAINTED WITH A SUITABLE GOOD QUALITY HIGH BUILD EPOXY ZINC PHOSPHATE PRIMER TOPROVIDE A DRY FILM THICKNESS OF NOT LESS THAN 75 MICRONS. A PRE-FABRICATION PRIMER MAY BE USED AT THE FABRICATORSDISCRETION. THE CONTRACTOR SHALL ENSURE THAT THE PRIMER USED IS COMPATIBLE WITH SUBSEQUENT COATINGS SPECIFIEDBY OTHERS. (E.G. INTUMESCENT PAINT).
10. STEELWORK SPECIFIED AS GALVANISED SHALL BE BLAST CLEANED AS ABOVE & HOT DIP GALVANISED TO B.S.729 MINIMUM COATINGTHICKNESS 85 MICRONS.
11. ALL STEELWORK BELOW DPC LEVEL OR BUILT WITHIN THE MASONRY WALL CAVITY SHALL BE SITE PAINTED WITH A COMPATIBLE HIGHBUILD EPOXY ZINC PHOSPHATE PRIMER TO PROVIDE A DRY FILM THICKNESS OF NOT LESS THAN 125 MICRONS, TO ACHIEVE ANOVERALL PRIMER COATING OF 200 MICRONS. I.E. LEIGHS PAINTS EPIGRIP C400 ZINC PHOSPHATE PRIMER/BUILDCOAT OR EQUAL.STEELWORK BELOW DPC SHALL ALSO BE ENCASED IN NOT LESS THAN 100MM OF CONCRETE NOT WEAKER THAN SPECIFIED ON THEDRAWINGS.
12. STEELWORK CONTRACTOR TO CO-ORDINATE WITH MAIN CONTRACTOR AND CLADDING CONTRACTOR TO PROVIDE ALL NECESSARYSECONDARY STEELWORK, TRIMMING ETC. AS REQUIRED AROUND ALL DOORS, WINDOWS AND THE LIKE.
13. STEELWORK CONTRACTOR TO CO-ORDINATE WITH MAIN CONTRACTOR TO PROVIDE ADEQUATE TEMPORARY BRACING DURING THESEQUENCE OF ERECTION.
14. ANY CONCRETE ENCASED STEELWORK SHALL BE CLEANED OF ALL LOOSE SCALE, RUST, DIRT AND BE FREE OF ANY GREASE.
15. ALL STEELWORK FIRE PROTECTION TO ARCHITECTS SPECIFICATION AND DETAILS. IF INTUMESCENT PAINT IS USED, ENSURECOMPATIBILITY WITH ANY PRIMERS OR SECONDARY COVERINGS
STRUCTURAL MASONRY NOTES
1. REFER TO ARCHITECTURAL DRAWINGS AND SPECIFICATION FOR MASONRY REQUIREMENTS IN RESPECT OF ACOUSTIC, THERMALINSULATION AND DURABILITY REQUIREMENTS. THE ENGINEER SHALL BE NOTIFIED IMMEDIATELY IF THIS CONFLICTS WITHSTRUCTURAL REQUIREMENTS.
2. BLOCKWORK TO HAVE A MINIMUM COMPRESSIVE STRENGTH OF 7.0N/mm². BLOCKWORK LINER TO CAVITY DRAIN TO BE SPECIFIEDBY THE CAVITY DRAIN SUPPLIER. ALL BLOCKWORK TO BE SOLID AND IS TO COMPLY WITH BS5628, TABLE 4, REQUIREMENTS FORSPECIAL CATEGORY OF MANUFACTURE.
3. THE MAXIMUM WEIGHT OF AN INDIVIDUAL MASONRY UNIT MUST NOT EXCEED 20KG.
4. BLOCKWORK SHOULD BE ADEQUATELY PROTECTED ON SITE TO AVOID SATURATION AND POSSIBLE INCREASE IN LIFTING WEIGHT.REFERENCE SHALL BE MADE TO THE PROJECT ARCHITECT/ACOUSTIC CONSULTANT FOR COMPLIANCE WITH PART E OF THEBUILDING REGULATION - SOUND TRANSMISSION.
5. BLOCKWORK BELOW DPC TO BE OF FOUNDATION QUALITY (REFER TO MANUFACTURERS GUIDELINES) AND TO BE OF AT LEASTEQUAL MINIMUM COMPRESSIVE STRENGTH TO THAT INDICATED BETWEEN GROUND AND FIRST FLOOR AND IN NO CASE LESS THAN7N/mm².
6. BRICKWORK TO HAVE A MINIMUM COMPRESSIVE STRENGTH OF 20N/MM² AND IS TO COMPLY WITH BS5628 REQUIREMENTS FORSPECIAL CATEGORY OF MANUFACTURE.
7. MORTAR DESIGNATION AS FOLLOWS:ABOVE DPC MORTAR DESIGNATION iiiBELOW DPC MORTAR DESIGNATION ii
8. REFER TO THE ARCHITECTS DRAWINGS FOR DETAILS OF DPC'S, DPM'S, WATERPROOFING AND INSULATION.
9. LINTELS:FOR ALL BLOCKWORK WALLS PROVIDE PROPRIETARY PRE-CAST CONCRETE LINTELS AS SPECIFIED ON THE DRAWINGS OREQUIVALENT APPROVED BY ALTERNATIVE MANUFACTURER.
FOR ALL CAVITY WALLS PROVIDE PROPRIETARY IG LINTEL TO SUIT CAVITY WIDTH OR EQUIVALENT APPROVED BY ALTERNATIVEMANUFACTURER.
ALL STEEL LINTELS IN EXTERNAL WALLS TO BE FULLY GALVANISED OR PROVIDED WITH SOME OTHER SUITABLE PROTECTIONAGAINST MOISTURE AND HAVE A MINIMUM 150mm BEARING TO EACH END UNLESS NOTED OTHERWISE.
CONCRETE
1. ALL CONCRETE TO BE NORMAL WEIGHT, STRENGTH GRADE C28/35 TO PROVIDE A MINIMUM CUBE COMPRESSIVE STRENGTH OF35N/mm² AT 28 DAYS.
2. ALL CONCRETE BELOW GROUND LEVEL (SLABS, WALLS & FOUNDATIONS) TO BE DESIGNED FOR A DESIGN SULPHATE CLASS OFDS-2.
3. UNDER NO CIRCUMSTANCES IS CONCRETE TO BE POURED IF EXPECTED TEMPERATURE WITHIN THE FOLLOWING 24 HOUR PERIOD ISEXPECTED TO BE 5° C OR LESS.
4. NO ADMIXTURES OF ANY FORM TO BE ADDED TO THE CONCRETE WITHOUT THE WRITTEN PERMISSION OF THE STRUCTURALENGINEER. IT IS STRICTLY FORBIDDEN TO ADD WATER TO CONCRETE ON SITE.
PILING & FOUNDATIONS
1. ALL PILING DESIGN IS TO BE CARRIED OUT BE THE CONTRACTOR TO SUIT THE GROUND CONDITIONS AS DESCRIBED IN THE SOILSREPORT SUPPLIED BY FASTRACK FSI REF 8023 JUNE 2013. AND TO ALL THE STRUCTURAL ENGINEER'S REQUIREMENTS.
2. CONTIGUOUS PILED WALLS HAVE BEEN SPECIFIED ON THE TENDER DRAWINGS. ALTERNATIVES MAY BE ACCEPTABLE. CONTRACTORTO SUBMIT ALTERNATIVE PROPOSALS TO THE STRUCTURAL ENGINEER FOR CONSIDERATION AND AGREEMENT.
3. ALL CONCRETE MIX TO PILES TO SPECIFIED BY PILING DESIGNER WITH CONSIDERATION TO STRUCTURAL REQUIREMENTS AND SOILSREPORT.
4. FOR PURPOSES OF TENDER ASSUME ALL PILE EXTEND FOR A FURTHER 15 METRES BELOW BASEMENT SLAB. FINAL LENGTHS TO BECONFIRMED BY PILING CONTRACTOR.
5. PILING CONTRACTOR TO SUBMIT ALL PILING DESIGN TO STRUCTURAL ENGINEER FOR REVIEW AND COMMENT.
TIMBER FLOOR CONSTRUCTION NOTES
1. ALL STRUCTURAL TIMBER FLOOR MEMBERS TO BE OF MINIMUM SIZE AS SHOWN ON THE DETAIL DRAWINGS. SIZES SHOWN ARENOMINAL TIMBER SIZES EXCEPT AS NOTED ON THE DRAWINGS AND WILL BE SUBJECT TO REDUCTIONS IN FINISHED SIZE TO B.S.4471
2. TIMBER FLOOR JOIST SHALL HAVE MINIMUM BEARINGS OF 100MM ON MASONRY AND 75MM ON STEEL BEAMS OR TIMBER PLATESEXCEPT AS NOTED ON THE DRAWINGS. TIMBER FLOOR JOISTS SHALL NOT BE BUILT INTO PARTY WALL CONSTRUCTIONS BUT SHALLBE SUPPORTED ON PROPRIETARY JOIST HANGERS AT SUCH LOCATIONS. RESTRAINT TYPE JOISTS HANGERS CAPABLE OF RESISTINGTENSILE FORCES, IN ACCORDANCE WITH BS 5628-1 APPENDIX C TO BE USED. ALTERNATIVELY, PROVIDE RESTRAINT STRAPS AT NOTMORE THAN 2.0M CENTRES USING 30MM X 5MM GALVANISED STRAPS WITH A TURN DOWN LENGTH OF 100MM AND STRAIGHTLENGTH OF 600MM. STRAPS FIXED TO FLOOR JOISTS WITH 50MM, NO.10 SCREWS AT NOT MORE THAN 110MM CENTRES AND AMINIMUM OF 4 FIXINGS.
3. DOUBLE JOISTS SHALL BE PROVIDED UNDER NON-LOAD BEARING STUDWORK PARTITIONS RUNNING PARALLEL WITH JOIST SPANS,UNDER BATHS AND UNDER AIRING CU--OARD
4. ALL MEMBERS SUPPORTED ON PROPRIETARY HANGERS SHALL BE ACCURATELY CUT TO PROVIDE A FULL CONTACT WITH THE BASEOF THE HANGER AND SHALL BE FIXED IN ACCORDANCE WITH THE HANGER MANUFACTURER'S INSTRUCTIONS. JOISTS SHALL BEREBATED TO LIE FLUSH WITH UNDERSIDE OF HANGERS.
5. ALL MEMBERS FITTED INTO STEEL BEAMS SHALL PROVIDE A GOOD FIT TO THE WEB OF THE BEAM AND SHALL BE NOTCHED THEMINIMUM AMOUNT REQUIRED TO CLEAR THE BEAM FLANGES. WHERE STEEL BEAMS ARE SPECIFIED WITHIN THE FLOOR DEPTH, THEUNDERSIDE OF JOISTS SHALL BE 5MM BELOW THE UNDERSIDE OF THE BEAMS.
6. EXTERNAL AND PARTY WALLS PARALLEL WITH JOISTS SPANS SHALL BE RESTRAINED AT TOP OF FLOOR JOIST LEVEL AT NOT MORETHAN 2.0M CENTRES WITH GALVANISED 30 X 5.0MM STRAPS EXTENDING OVER A MINIMUM OF 3 JOISTS. NOGGINS NOT LESS THEN75% OF JOIST DEPTH AND TIMBER BLOCKING ADJACENT TO WALLS SHALL BE FIXED BETWEEN JOISTS AT ALL STRAP LOCATIONS.STRAPS SHALL BE FIXED TO MEMBERS/NOGGINS WITH NOT LESS THAN 4 NO. 32 X 3.5MM GALVANISED OR SHERARDISED SQUARETWISTED NAILS.
7. END JOISTS SHALL BE POSITIONED APPROXIMATELY 50MM FROM MASONRY WALLS. JOIST CENTRES GENERALLY SHALL BE EQUALAND SHALL NOT EXCEED THE DESIGN CENTRES SHOWN ON THE DRAWING. MULTIPLE JOISTS, WHERE SHOWN ON THE DRAWINGSSHALL BE SECURELY NAILED TOGETHER AT NOT MORE THAN 600MM CENTRES.
8. UNLESS SPECIFIED OTHERWISE, SECURELY FIX STRUTTING BETWEEN JOISTS AT CENTRES AS FOLLOWS: JOIST SPAN OF 2.5M TO 4.5M: - ONE ROW AT CENTRE OF SPAN. JOIST SPAN OVER 4.5M: - TWO ROWS EQUALLY SPACED
STRUTTING SHALL TAKE THE FORM OF ONE OF THE FOLLOWING.38MM X 38MM SOFTWOOD HERRINGBONE STRUTTING LOCATED BETWEEN 5 & 25MM CLEAR OF TOP AND BOTTOM EDGES OF
JOIST.PROPRIETARY GALVANISED METAL STRUTTING FIXED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.SOLID SOFTWOOD STRUTTING NOT LESS THAN 38MM THICK AT LEAST THREE QUARTERS OF THE DEPTH OF THE JOIST
STRUCTURAL UNDERPINNING NOTES
1. TO BE READ IN CONJUNCTION WITH THE PRELIMINARIES AND GENERAL CONDITIONS.2. WORKMANSHIP: THE WORK SHALL BE CARRIED OUT IN ACCORDANCE WITH THE ENGINEER'S DRAWINGS AND INSTRUCTIONS AND TO
THE APPROVAL OF THE ARCHITECT AND THE BUILDING CONTROL OFFICER.
3. ANY OTHER SEQUENCE OF OPERATIONS OR METHOD OF WORKING PROPOSED BY THE CONTRACTOR IS TO BE SUBMITTED TO THEARCHITECT AND COPIED TO THE ENGINEER AND AGREED IN WRITING A MINIMUM OF 14 DAYS BEFORE WORK IS TO BE COMMENCEDON SITE.
4. CONTRACTORS RESPONSIBILITIES: THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE SAFETY OF THE UNDERPINNED STRUCTUREAND PROVIDE ALL NECESSARY SHORING, STRUTTING AND BRACING TO ENSURE ITS SAFETY AND STABILITY AT ALL TIMES.
5. SERVICES: THE CONTRACTOR IS ALSO TO CARRY OUT A SURVEY OF THE PROPERTY AND ADJACENT AREA TO ESTABLISH THE
LOCATION OF OBSTRUCTIONS SUCH AS SERVICE RUNS OR DRAINS. ANY OBSTRUCTION FOUND IS TO BE BROUGHT TO THEATTENTION OF THE ARCHITECT / ENGINEER.THE CONTRACTOR IS TO ALLOW FOR ANY TEMPORARY SUPPORT TO THE SERVICES OROBSTRUCTIONS DURING THE UNDERPINNING.
6. CONSTRUCTION SEQUENCE: THE UNDERPINNING IS TO BE UNDERTAKEN IN SHORT SECTIONS NOT EXCEEDING 1 METRE IN LENGTH.THE UNDERPINNING IS TO BE UNDERTAKEN ON A 'HIT AND MISS' SEQUENCE.
7. NO ADJACENT PIN IS TO BE EXCAVATED UNTIL A MINIMUM 48 HOURS AFTER THE ADJACENT PIN HAS BEEN CAST AND PACKED UP.
8. THE CONTRACTOR IS TO PROVIDE DRAWINGS MARKED UP TO SHOW THE PROPOSED SEQUENCE OF UNDERPINNING A MINIMUM OF14 DAYS BEFORE WORK IS COMMENCED.
9. EXCAVATIONS: EXCAVATION SHALL BE TO THE DEPTH AND WIDTH SHOWN ON THE DRAWINGS. HOWEVER,WHERE TREE ROOTS AREENCOUNTERED NEW UNDERPINS ARE TO EXTEND 600MM BELOW THE LAST TRACE OF ANY ROOT ACTIVITY. THE SIDES OF THEEXCAVATIONS SHALL BE ADEQUATELY SHORED AND PROPPED TO PREVENT SUBSIDENCE OR SLIP OF THE SOIL. SOIL FACES BEHINDTHE PIN AND AT THE FORMATION LEVEL SHALL BE UNDISTURBED.
10. ANY SOIL FACES BEHIND THE UNDERPINNING THAT REQUIRE TO BE RETAINED SHALL BE BY PRECAST CONCRETE POLING BOARDS.THE BOARDS ARE TO HAVE HOLES TO ENABLE THE VOID BEHIND THE BOARDS TO BE GROUTED UP. THE POLING BOARDS ARE TO BEMEASURED AS LEFT IN.
11. INSPECTIONS: ALL EXCAVATIONS ARE TO BE INSPECTED BY THE ENGINEER AND/OR THE BUILDING CONTROL OFFICER. MINIMUMNOTICE OF 24 HOURS IS TO BE GIVEN WHEN EXCAVATIONS ARE READY FOR INSPECTION.
12. THE SOFFIT OF THE EXISTING FOOTINGS IS TO BE LEVELED OFF AND CLEANED OF ALL LOOSE OR DETRIMENTAL MATERIAL.
13. NO PROJECTING PORTIONS OF THE EXISTING FOOTINGS ARE TO BE TRIMMED EXCEPT AS SHOWN ON THE DRAWINGS OR DIRECTEDBY THE ENGINEER.
14. ANTI-HEAVE PRECAUTIONS: BEFORE CARRYING OUT CONCRETING INTRODUCE ANTI-HEAVE PRECAUTIONS IN THE FORM OF CLAYMASTER AS DIRECTED BY THE ENGINEER TO THE FACES OF THE EXCAVATION.
15. PLACING CONCRETE: THE CONCRETE FOR THE UNDERPINNING IS TO BE RC35 CONCRETE AND POURED CONTINUOUSLY TO 75MMBELOW THE SOFFIT OF THE EXISTING FOOTING. THE CONCRETE IS TO BE FULLY COMPACTED USING A MECHANICAL VIBRATOR.
16. THE TOP 75MM OF THE PIN IS TO BE FILLED TO THE FULL DEPTH AND WIDTH OF THE VOID WITH A 3:1 SHARP SAND:CEMENT MIX DRYPACK MIXED HAND DAMP AND RAMMED IN WELL SOLID.