7/23/2019 7302 7330 ISAM R2 5 Product Information
1/112
Alcatel 7302 ISAMINTELLIGENT SERVICES ACCESS MANAGER | RELEASE 2.5.XP R O D U C T I N F O R M A T I O N
3HH-03574-AAAA-TCZZA Edit ion 02 Released
7/23/2019 7302 7330 ISAM R2 5 Product Information
2/112
PRINTED ONRECYCLED PAPER
Alcatel assumes no responsibility for the accuracy of the information presented, which is subject tochange without notice.
Alcatel and the Alcatel logo are registered trademarks of Alcatel. All other trademarks are the propertyof their respective owners.
Copyright 2006 Alcatel.All rights reserved.
Disclaimers
Alcatel products are intended for commercial uses. Without the appropriate network designengineering, they must not be sold, licensed or otherwise distributed for use in any hazardousenvironments requiring fail-safe performance, such as in the operation of nuclear facilities, aircraftnavigation or communication systems, air traffic control, direct life-support machines, or weaponssystems, in which the failure of products could lead directly to death, personal injury, or severe physicalor environmental damage. The customer hereby agrees that the use, sale, licence or other distribution
of the products for any such application without the prior written consent of Alcatel, shall be at thecustomer's sole risk. The customer hereby agrees to defend and hold Alcatel harmless from any claimsfor loss, cost, damage, expense or liability that may arise out of or in connection with the use, sale,licence or other distribution of the products in such applications.
This document may contain information regarding the use and installation of non-Alcatel products.Please note that this information is provided as a courtesy to assist you. While Alcatel tries to ensurethat this information accurately reflects information provided by the supplier, please refer to thematerials provided with any non-Alcatel product and contact the supplier for confirmation. Alcatelassumes no responsibility or liability for incorrect or incomplete information provided aboutnon-Alcatel products.
However, this does not constitute a representation or warranty. The warranties provided for Alcatel
products, if any, are set forth in contractual documentation entered into by Alcatel and its customers.
This document was originally written in English. If there is any conflict or inconsistency between theEnglish version and any other version of a document, the English version shall prevail.
7/23/2019 7302 7330 ISAM R2 5 Product Information
3/112
Alcatel 7302 ISAM R2.5.x October 2006 iii
Product Information 3HH-03574-AAAA-TCZZA Edition 02 Released
Preface
This preface provides general information about the documentation set for the7302 Intelligent Services Access Manager (7302 ISAM).
Scope
This documentation set provides information about safety, features andfunctionality, ordering, hardware installation and maintenance, CLI and TL1commands, and software upgrade and migration procedures.
Audience
This documentation set is intended for planners, administrators, operators, andmaintenance personnel involved in installing, upgrading, or maintaining the7302 ISAM.
Prerequisite knowledge
The reader must be familiar with general telecommunications principles.
Safety information
For ETSI safety information, see the 7302 ISAM Safety Manual.
7/23/2019 7302 7330 ISAM R2 5 Product Information
4/112
Preface
iv October 2006 Alcatel 7302 ISAM R2.5.x
Edition 02 Released 3HH-03574-AAAA-TCZZA Product Information
Documents
Table 1lists the documents that make up the 7302 ISAM Release 2.5.xdocumentationset.
Table 1 7302 ISAM documentation set
Title Description Part number
General documentation
Product Information Provides general system information for the 7302 ISAM 3HH-03574-AAAA-TCZZA
System Description Provides conceptual information for the 7302 ISAM and the7330 ISAM FTTN
3HH-03573-AAAA-TQZZA
Safety Manual Provides general safety guidelines when handling, installing,or operating the 7302 ISAM equipment
3HH-03579-AAAA-TCZZA
Operations and MaintenanceUsing CLI
Provides task-oriented procedures for operating andmaintaining the 7302 ISAM and 7330 ISAM FTTN using theCLI
3HH-03580-AAAA-TQZZA
Migration User Guide Provides information for installing or upgrading the 7302 ISAM 3HH-03576-AAAA-TQZZA
Hardware documentation
Hardware Installation Guide Describes the hardware installation for the 7302 ISAMequipment
3FE-21578-AAAA-RJZZA
CLI and TL1 documentation
CLI Commands Describes the CLI commands for the 7302 ISAM and the7330 ISAM FTTN
3HH-03577-AAAA-TCZZA
TL1 Commands andMessages
Describes the TL1 commands and messages for the7302 ISAM and the 7330 ISAM FTTN
3HH-03578-AAAA-TCZZA
Software documentation
Software Management UserGuide Describes the software management of the 7302 ISAMequipment 3HH-03390-AAAA-RJZZA
7/23/2019 7302 7330 ISAM R2 5 Product Information
5/112
Preface
Alcatel 7302 ISAM R2.5.x October 2006 v
Product Information 3HH-03574-AAAA-TCZZA Edition 02 Released
Special information
The following are examples of how special information is presented in thisdocument.
Danger Danger indicates that the described activity or situationmay result in serious personal injury or death; for example, highvoltage or electric shock hazards.
Warning Warning indicates that the described activity or situationmay, or will, cause equipment damage or serious performanceproblems.
Caution Caution indicates that the described activity or situationmay, or will, cause service interruption.
Note A note provides information that is, or may be, of specialinterest.
7/23/2019 7302 7330 ISAM R2 5 Product Information
6/112
Preface
vi October 2006 Alcatel 7302 ISAM R2.5.x
Edition 02 Released 3HH-03574-AAAA-TCZZA Product Information
Procedures with options or substeps
When there are options in a procedure, they are identified by letters. When there arerequired substeps in a procedure, they are identified by Roman numerals.
Procedure 1 Example of options in a procedure
At step 1, you can choose option a or b. At step 2, you must do what the step indicates.
1 This step offers two options. You must choose one of the following:
a This is one option.
b This is another option.
2 You must perform this step.
Procedure 2 Example of required substeps in a procedure
At step 1, you must perform a series of substeps within a step. At step 2, you must do
what the step indicates.
1 This step has a series of substeps that you must perform to complete the step. You
must perform the following substeps:
i This is the first substep.
ii This is the second substep.
iii This is the third substep.
2 You must perform this step.
Measurement conventions
Measurements in this document are expressed in imperial units. If metricmeasurements are included, they appear in brackets following the imperialmeasurement. The metric measurements follow the Systme international dunits(SI) standard for abbreviation of metric units.
7/23/2019 7302 7330 ISAM R2 5 Product Information
7/112
Alcatel 7302 ISAM R2.5.x October 2006 vii
Product Information 3HH-03574-AAAA-TCZZA Edition 02 Released
Contents
Preface iiiScope .............................................................................................................................. iiiAudience .............................................................................................................................. iii
Prerequisite knowledge ......................................................................................................... iiiSafety information.................................................................................................................. iiiDocuments ............................................................................................................................iv
Special information .................................................................................................................v
1 System Overview 1-1
1.1 Introduction........................................................................................................ 1-21.2 System Architecture........................................................................................... 1-4
1.3 IWF Capabilities................................................................................................. 1-81.4 ISAM with integrated Voice-band services ...................................................... 1-10
2 Software Architecture 2-12.1 General .............................................................................................................. 2-2
2.2 7302 ISAM System Initialization ........................................................................ 2-42.3 Network Management........................................................................................ 2-6
3 Subracks 3-13.1 Introduction........................................................................................................ 3-23.2 General .............................................................................................................. 3-2
3.3 XD Splitterless Subrack (ALTS-T) ..................................................................... 3-33.4 XD Splitter Subrack (ASPS-A)........................................................................... 3-83.5 XD Standard Splitter Subrack (ASPS-C) ......................................................... 3-11
3.6 XD-Combo300 Subrack (ALTS-U)................................................................... 3-143.7 Weight of the Different Components................................................................ 3-19
7/23/2019 7302 7330 ISAM R2 5 Product Information
8/112
Contents
viii October 2006 Alcatel 7302 ISAM R2.5.x
Edition 02 Released 3HH-03574-AAAA-TCZZA Product Information
4 Physical Rack Equipment 4-14.1 Rack Equipment for XD-LT, XD-SP and XD Standard Splitter .......................... 4-2
4.2 Rack Equipment for XD-Combo300 .................................................................. 4-6
5 Rack Configurations 5-15.1 Introduction........................................................................................................ 5-2
5.2 Rack Configurations .......................................................................................... 5-25.3 XD Modular Rack Configurations ...................................................................... 5-3
5.4 XD-Combo300 Rack Configurations.................................................................. 5-7
6 Standards and Restrictions 6-16.1 Introduction........................................................................................................ 6-2
6.2 EMC Standards and Restrictions....................................................................... 6-26.3 Environmental Standards and Restrictions........................................................ 6-3
6.4 Fiber Handling Restrictions................................................................................ 6-36.5 1+1 NT Redundancy Support ............................................................................ 6-5
6.6 MTA and 1:N LT Redundancy Support.............................................................. 6-7
A. Mnemonics A-1App A.1 Mnemonics ........................................................................................................A-2
Glossary
Index
7/23/2019 7302 7330 ISAM R2 5 Product Information
9/112
Alcatel 7302 ISAM R2.5.x October 2006 1-1
Product Information 3HH-03574-AAAA-TCZZA Edition 02 Released
1 System Overview
1.1 Introduction 1-2
1.2 System Architecture 1-4
1.3 IWF Capabilities 1-8
1.4 ISAM with integrated Voice-band services 1-10
7/23/2019 7302 7330 ISAM R2 5 Product Information
10/112
1 System Overview
1-2 October 2006 Alcatel 7302 ISAM R2.5.x
Edition 02 Released 3HH-03574-AAAA-TCZZA Product Information
1.1 Introduction
The 7302 ISAM is a frame based Digital Subscriber Line Access Multiplexer(DSLAM), that is, a Digital Subscriber Line (DSL) access multiplexer which isbased on a frame forwarding architecture in a packet aggregation network.
General Network Topology
Figure 1-1shows the basic network topology:
Figure 1-1 General network topology
User Side
At the user side, each 7302 ISAM terminates DSL links and a limited number of FEor GE links.
It is possible to connect subtending DSLAMs to the FE/GE links at the user side in:
cascading mode: a chain of 1 subtending ISAM per ISAM star mode: multiple subtending ISAMs per ISAM ring mode (except when there is a ring behind a Hub-ISAM).
Figure 1-2shows the cascading topology.
Figure 1-2 Cascading Topology
ADSL
FE/GE
ISAM
FE/GE
FE/GE
IP Edge Router/ BRAS
EMAN
EthernetSwitch
NSP IP backbone
NSP IP backbone
NSP IP backbone
ISAMISAM
Cascading up t o three levels
7/23/2019 7302 7330 ISAM R2 5 Product Information
11/112
1 System Overview
Alcatel 7302 ISAM R2.5.x October 2006 1-3
Product Information 3HH-03574-AAAA-TCZZA Edition 02 Released
Network Side
At the network side, the 7302 ISAM terminates GE or FE links. The followingconfigurations are possible:
Connected to one or more Ethernet SwitchesThe Ethernet links can be connected to one or more Ethernet Switches. TheseEthernet Switches forward the frames over the Ethernet based aggregation accessnetwork until they reach the IP Edge Router or BRAS of the correspondingNetwork Service Provider (NSP). At the IP Edge Router or BRAS, the framesenter the IP backbone of the NSP.
More than one FE/GE link (link aggregation)In case of more than one FE or GE, Ethernet link aggregation is used.
Directly connected to an IP Edge RouterThe 7302 ISAM can be connected directly to the IP Edge Router or BRAS. TheEthernet aggregation network is reduced to one or more parallel Ethernet links.
Note:A link is a term which is used to refer to the physical layer of an interface ofthe 7302 ISAM, for example, an ADSL link, an Ethernet link.
7/23/2019 7302 7330 ISAM R2 5 Product Information
12/112
1 System Overview
1-4 October 2006 Alcatel 7302 ISAM R2.5.x
Edition 02 Released 3HH-03574-AAAA-TCZZA Product Information
1.2 System Architecture
GeneralThe figure below shows the general functional architectures of the 7302 ISAM.
Figure 1-3 7302 ISAM Functional Architecture
The system consists of a Gigabit Ethernet switch fabric, that bridges or routes user,
subscriber control and network management traffic between:
on the subscriber side:a set of subscriber line interfaces and a number of sub-tending interfaces towardsother, hierarchically subordinate DSLAM systems.
on the network side:one or more Network Termination (NT) interfaces.
7302 ISAM Subsystems
The 7302 ISAM is composed of the:
ISAM Access termination Control and Management (IACM) subsystemThis subsystem:
contains the control functions of the 7302 ISAM on the NT board. provides management interfaces on the NT board to the outside worlds and control
interfaces towards other boards (LT boards, NT I/O board).
contains the LT boards. contains the NT I/O board.
Service Hub (SHub) subsystemThis subsystem contains the system switch fabric function of the 7302 ISAM.
NTControl
T T T T
1 FE cont rol link
LT
L L L L
SHub subsystem(24 FE / GE ports)
...
ISAMnetwork
... 48 xDSL linesper LT
user links
......
7-n FE/GE
user or
subtending
links
NTControl
T T T T
1 FE control link
n FE/GE
network
links
16 GE links to DSL Line cards
7/23/2019 7302 7330 ISAM R2 5 Product Information
13/112
1 System Overview
Alcatel 7302 ISAM R2.5.x October 2006 1-5
Product Information 3HH-03574-AAAA-TCZZA Edition 02 Released
IACM Subsystem
Network Termination Boards
The following NT boards are supported in this release:
ECNT-ANT board with integrated SHub subsystem. Provides three electrical FE,electrical GE or optical GE links on the front panel.
ECNT-CNT board with integrated SHub subsystem. Provides four GE links on the frontpanel:
3 GE optical 1 GE optical/electrical (selectable)
NT I/O-Boards
The following NT I/O boards are supported in this release:
Table 1-1 NT I/O Boards
Board Interfaces Description / Remark
ECNC-A Four additional external Ethernetinterfaces:
GE Optical or 10/100/1000 Electrical
NT - NT I/O pair provides seven FE/GEinterfaces available for network / subtending /user links
All can be GE Optical or 10/100/1000 Electrical
ECNC-B Four additional external Ethernetinterfaces:
FE Optical
NT - NT I/O pair provides seven FE/GEinterfaces available for network / subtending /user links
Three can be GE Optical or 10/100/1000Electrical
Four can be GE Optical
ECNC-C Four additional external Ethernetinterfaces:
3 GE Optical 1 GE Electrical/Optical
(selectable)
NT - NT I/O pair provides eight optical GEinterfaces available for network / subtending /user links
RJ45 BITS interface
7/23/2019 7302 7330 ISAM R2 5 Product Information
14/112
1 System Overview
1-6 October 2006 Alcatel 7302 ISAM R2.5.x
Edition 02 Released 3HH-03574-AAAA-TCZZA Product Information
Line Termination Boards
The LT boards, a.k.a. Line Interface Modules (LIMs), use a different interworkingfunction between the user side and the Ethernet network side, depending on the boardtype. The table below shows the supported LT boards with their supportedforwarding models.
Table 1-2 LT Boards with Supported Forwarding Models
Notes(1)
L2: InterWorking Function (IWF) capability on Layer 2 onlyFor an overview of the supported IWF capabilities, refer to section 1.3(2) L2/L3: IWF function capability on Layer 2 and Layer 3
For an overview of the supported IWF capabilities, refer to section 1.3
For an overview of the supported splitter boards, refer to Tables 3-3, 3-5, 3-7and 3-9.
LT Board Supported Forwarding Model
BALT-A -
EALT-A L2
EBLT-A L2
EBLT-C L2 / L3
EBLT-D L2 / L3
EBLT-E L2 / L3
EBLT-F L2 / L3
EBLT-J L2
EBLT-K L2 / L3
EBLT-L L2 / L3
EVLT-C L2 / L3
EVLT-D L2 / L3
SMLT-J L2/L3
7/23/2019 7302 7330 ISAM R2 5 Product Information
15/112
1 System Overview
Alcatel 7302 ISAM R2.5.x October 2006 1-7
Product Information 3HH-03574-AAAA-TCZZA Edition 02 Released
SHub Subsystem
The Service Hub (SHub) subsystem multiplexes the Ethernet frames into a reducedset of network links (that is, aggregates traffic from / to subscriber interfaces on oneor a limited number of network uplinks).
The SHub subsystem is integrated in a NT board. Figure 1-4shows the connectionsof the LT shelf with the SHub subsystem. The SHub subsystem provides 24 FE/GEports:
16 ports are used for connecting to each LT board one port used for internal purposes (ECNT-A only)
seven external ethernet ports with an optical, electrical FE or GE interface, whichcan be used for network uplinks, subtending links (aggregation of traffic from or
to other DSLAMs) or Ethernet subscriber links.These seven ports are physically available:
three on the Network Termination (NT) board itself four on the NT I/O board.
Figure 1-4 LT Shelf with SHub Subsystem
Note This is valid for the ECNT-A only.
For the ECNT-C, internal communications pass via the PCI interface.This allows to support one additional interface on the front of this NT.
Network ports(mandatory)
LT shelf ports(mandatory)
Up to 7 FEor GE links
Subtending ports(optional)
16 HCL links(GE)
LIM
48 lines
NTwith SHub subsystem
LT shelf
7/23/2019 7302 7330 ISAM R2 5 Product Information
16/112
1 System Overview
1-8 October 2006 Alcatel 7302 ISAM R2.5.x
Edition 02 Released 3HH-03574-AAAA-TCZZA Product Information
1.3 IWF Capabilities
The table below gives an overview of the IWF capabilities of the LT boards. Referto Table 1-2for an overview of the supported LT boards
Table 1-3 IWF Capabilities
Feature L2 L2/L3
ATM AAL5 encapsulation types
LLC/SNAP bridged (IpoE and PPPoE) Y Y
LLC/SNAP routed (IpoA) - Y
LLC/NLPid (PPPoA) - Y
VC Mux Bridged (IpoE and PPPoE) - Y
VC Mux Routed (IpoA) - Y
VC Mux PPPoA (PPPoA) - Y
Encapsulation autodetect
Autodetect IP (between LLC/SNAP bridged and routed) - Y
Autodetect PPP (between LLC/SNAP bridged, VC Mux Bridged andLLC-NLPID, VC Mux PPPoA)
- Y
Autodetect PPPoA (between LLC-NLPID and VC Mux PPPoA) - Y
Bridged Encapsulation Ethernet Packet formats
Reception of untagged packets Y Y
Reception of combination of untagged and priority tagged packets - Y
Reception of single tagged packets - Y
Reception of combination of untagged, priority tagged, single tagged
packets
- Y
Packet processing
Port Based Default VLAN for untagged / priority tagged (if applicable)packets
Y Y
Port and Protocol Based default VLAN for untagged / priority tagged packetsof the IpoE Protocols
- Y
Port and Protocol Based default VLAN for untagged / priority tagged packetsof the PPPoE Protocols
- Y
Priority Bit Remarking and Mapping table for tagged / priority tagged packets - Y
L2 Forwarding
RB mode: Protocol Filter (set of Ethertypes) for upstream traffic in VLANs in(PPPoE and IpoE)
Y Y
RB mode Ethernet packet types: Ethernet II Encap on Ethernet Y Y
RB mode Ethernet packet types: LLC/SNAP on Ethernet - Y
CC Mode: transparently pass all encapsulations (e.g. PPPoE and IpoE) Y Y
CC Mode: Protocol Filter - Y
CC Mode: IPoA to IPoE CC - Y
(1 of 2)
7/23/2019 7302 7330 ISAM R2 5 Product Information
17/112
1 System Overview
Alcatel 7302 ISAM R2.5.x October 2006 1-9
Product Information 3HH-03574-AAAA-TCZZA Edition 02 Released
VLAN stacking (S-VLAN CC and S-VLAN / C-VLAN CC) Y Y
Qos-aware CC Y Y
L2 Forwarding user access protocols
ARP: enabling/disabling broadcast Y Y
802.1X authentication Y Y
DHCP option 82 insertion Y Y
PPPoE relay tag Y Y
PPPoA-PPPoE relay - Y
multicast services Y Y
L3 Forwarding
PPPoE - Y
IPoE - Y
IPoA - Y
VLAN termination (at network side), forwarding at Layer 3 - Y
L3 Forwarding user access protocols
802.1X authentication - Y
DHCP relay - Y
QOS
CAC profile Y Y
Association of QOS profiles to ports - Y
Association of QOS profiles to port-VLAN associations - Y
Subflow counters - Y
Dimensioning
Maximum Number of ADSL lines per LIM 48 48
Maximum Number of PVC per DSL Line 8 8
Maximum Number of VLANs (without VLAN stacking) 192+ 72 (MC)
768
Maximum Number of VLAN CCs with VLAN stacking 192 256
Maximum Number of VLAN per PVC 1 16
Maximum Number of MAC addresses per LIM (including static) 416+ 72 (MC)
1k
Maximum Number of user IP addresses per LIM (including static) - 384
Maximum number of VRFs node level - 128
Feature L2 L2/L3
(2 of 2)
7/23/2019 7302 7330 ISAM R2 5 Product Information
18/112
1 System Overview
1-10 October 2006 Alcatel 7302 ISAM R2.5.x
Edition 02 Released 3HH-03574-AAAA-TCZZA Product Information
1.4 ISAM with integrated Voice-band services
The ISAM with integrated Voice-band services (ISAM-V) provides support ofPOTS and ISDN services and connection to Next Generation Voice Networks(NGVN) via Voice over IP (VoIP).
Network Architecture
Figure 1-5shows the position of the ISAM-V in the NGVN.
Figure 1-5 Network Architecture
The ISAM-V acts as an Access Media Gateway (MG) and connects the legacyNarrowBand (NB) user interfaces (Plain Old Telephone Services (POTS) andIntegrated Services Digital Network (ISDN)) to the NGVN.
The ISAM-V supports: mixed configurations, where the NB user interfaces and MG Interface are integrated
in the same node
centralized configurations, where the MG Interface is located in a hub node and theNB user interfaces in remote nodes.
The trunk MG links the NGVN with a Legacy network. The softswitch is responsible for call control and charging, and communicates
with the MGs:
via the Media Gateway Control (MEGACO) protocol (ETSI RFC 3525 / ITU-TH.248) for POTS
via the SIGTRAN Control protocol for ISDN
Note H.248.16 (XDD Buffering) is also supported
Basically, XDD buffering is used in order not to lose digits when aftermatching with a valid dialplan the user still continues dialling. WhenXDD buffering is active, detected digits are kept in IVPS in a bufferas a digit string up to a timer expiration or when a new matching withthe current valid dialplan happens.
1540 Litespan AGW
IP
Softswitch
EMANPOTS,ISDN
ANT STB
BAS
Servers
IPedge
GW
Head officeISAM-V
POTS
ISDN
RemoteISAM-V
PSTNTGW
V5
Small RemoteISAM
SubtendingISAM-V
SIGTRAN
H.248
POTS
ISD
N
POTS
ISDN
ASPMGC
7/23/2019 7302 7330 ISAM R2 5 Product Information
19/112
1 System Overview
Alcatel 7302 ISAM R2.5.x October 2006 1-11
Product Information 3HH-03574-AAAA-TCZZA Edition 02 Released
Network Management
Figure 1-6shows a global view of the ISAM-V network management.
Figure 1-6 ISAM-V Network Management
5523 AWS
The 5523 AWS is the Element Manager in charge of the following functionality:
Equipment management SW download Configuration backup/restore (performed by the AWS module for VEM and
IVPS
Alarm management
Voice Element Manager
The operations related with voice service are performed on the IVPS (VoIP GW) viathe Voice Element Manager (VEM).
The VEM is the 5523 AWS module for Voice domain in charge of:
Media gateway interface management: Declare/delete MEGACO interface Configure MEGACO interface Activate/deactivate MEGACO interface List MEGACO interfaces in the NE Show MEGACO interface info Change CDE files
Signaling gateway management Create/delete signaling gateway Configure signaling gateway Activate/deactivate signaling gateway Show signaling gateway info
OSS GW
Clients
APC
OSS
5523 AWS
NT IVPS
VEM
Voice ServiceProvision / Assurance
Manager
Element
Manager
ISAM NE
5530 NA
7/23/2019 7302 7330 ISAM R2 5 Product Information
20/112
1 System Overview
1-12 October 2006 Alcatel 7302 ISAM R2.5.x
Edition 02 Released 3HH-03574-AAAA-TCZZA Product Information
Voice subscriber provisioning POTS/ISDN BA user ports management:
Declare/delete user port Configure user port (including L1 activation and D-packet Service indicator for
ISDN BA user ports).
Associate/de-associate user port to/from a MEGACO interface Set in/out service or shutdown user port List user ports linked to an IVPS Line testing for user ports Set line gain and line impedance for user port Assign POLT/BALT board (NE:/rack/subrack/slot/addressing info (based on
MAC/IP/UDP))
Providing a full integration with the rest of 5523 AWS domains.
APC
APC is the Voice Service Manager for Alcatel Access Nodes. It provides a full
abstraction of the underlying technology used to provide the service with thefollowing main features:
Voice subscriber provisioning and line testing for individual subscribers or a setof subscribers that allows fast deployment of the network
Open interfaces to OSS that eases massive deployment of the service, preventiveand customer-on-call line testing and subscriber information alignment withOSS.
5530 NA
The 5530 NA is in charge of the PSTN line Testing functionality, which includeselectrical measurements in the voice band to test the loop, testing of the POTS line
termination, and testing of the POTS terminal equipment.
Management Interface
The management interface between the VEM and the IVPS offers a SNMP v1protocol. There is also a direct interface (SNMPv1) between the APC and the IVPS.
The IVPS board is not equipped with a CT interface.
7/23/2019 7302 7330 ISAM R2 5 Product Information
21/112
1 System Overview
Alcatel 7302 ISAM R2.5.x October 2006 1-13
Product Information 3HH-03574-AAAA-TCZZA Edition 02 Released
Product Architecture
The ISAM Voice Package architecture is that of the ISAM with the addition of voiceservices, which translates into the addition of three boards:
one server board: IVPS, which is the VoIP gateway for ISAM-V
Note: the IVPS is plugged in an LT position, but performs server functions. two LIM boards:
POLT board, providing POTS interface connectivity BALT board, providing ISDN Basic Access (ISDN BA) interface connectivity
Architecture View
The following applies for the ISAM-V product architecture:
ISAM-V nodes are connected to an EMAN An ISAM-V node integrates either:
the server card, IVPS, performing the signaling and OAM functions of the GW
a number of NB LTs cards (POLT-A and BALT-A) performing the media functions both types together
MEGACO and SIGTRAN signaling and external voice service OAM areterminated at IVPS
Internal control and signaling communication between IVPS and NB LTs usesXLES protocol.
IVPS card is located into a hub node From the voice service point of view, one IVPS can control several ISAM-V
cascading nodes (up to 4 levels) with a number of NB LT cards as well as severalISAM-V distributed nodes (i.e. accessible via a common EMAN) with a numberof NB LT cards
All User Port in one NB LT are controlled from the same IVPS
Note: Although it is not a system constraint, the network deployment should beplanned so that all user ports in one shelf are associated to/ controlled by only oneIVPS. This is recommended for two different reasons:
simplest network architecture with an easier operation to keep compatibility with further features in order to limit the bandwidth/number
of calls per shelf
The different traffic flows related to voice service are isolated into differentVLANs which are defined over the EMAN and in the ISAM SHub:
Voice VLAN:RTP traffic and XLES signaling is carried over this VLAN
MEGACO VLAN:for MEGACO signaling traffic between CS and the media GW and
SIGTRAN signaling between ASP and the signalling GW External OAM VLAN:
for provider operation and management
Both hub and subtending (cascading or remote (distributed)) configurations arepossible. In cascading configurations, the connection to the hub is via Fast orGigabit Ethernet (optical or electrical) to the SHub of the hub node.
7/23/2019 7302 7330 ISAM R2 5 Product Information
22/112
1 System Overview
1-14 October 2006 Alcatel 7302 ISAM R2.5.x
Edition 02 Released 3HH-03574-AAAA-TCZZA Product Information
Figure 1-7shows the IVPS architecture.
Figure 1-7 ISAM Voice Package Architecture
Figure 1-8shows the IVPS subtended architecture.
Figure 1-8 ISAM Voice Package Subtended Architecture
EMAN
IVPS
NT
ISAM-V
POTS linesPOLT
ISDN- BA linesBALT
HCL GE
GE uplink
HCL GE
HCL GE
XLES signaling pathMEGACO signaling path
SIGTRAN signaling path
VoIP path
ASP
MGC
Analog voice path
Ethernet switch
EMAN
IVPS
Ethernet switch
NT
Eth
POLT/ISDN
Eth
POTS/ISDN BA lines
signalling path
voice path
ISAM-V Hub
GE
Ethernet switch
NT
POLT/ISDN
POTS/ISDN BA lines
Cascading ISAM-V
Ethernet switch
NT
POLT/ISDN
POTS/ISDN BA lines
Distributed ISAM-V
7/23/2019 7302 7330 ISAM R2 5 Product Information
23/112
1 System Overview
Alcatel 7302 ISAM R2.5.x October 2006 1-15
Product Information 3HH-03574-AAAA-TCZZA Edition 02 Released
IVPS
The IVPS communicates with the voice line boards by means of an extendedBLES (XLES) proprietary protocol. The IVPS terminates the proprietary signalingmessages from the voice boards, provides a MEGACO interface with the call serverand handles the specific OAM needed to support VoIP service.
The IVPS functions are:
The signaling interface with the call server or soft-switch (MEGACO signaling) Internal proprietary protocol (XLES) for signaling supervision and control with
POLT line termination boards Digit Map processing (either under Megaco reception or by CDE data) Specific OAM interface needed to support VoIP configuration and service Persistent storage of the voice service database including back-up and restore Regarding ISDN signaling:
IVPS performs message relay between the DSS1 XLES messages containing Q921and the IUA over SCTP messages that carry the Q931 info towards the ASP.
IVPS relies the ISDN signalling packets (DSS1) from/to UDP-XLES socket andtranslates those related to Q921 info (SAPI, TEI) to/from IUA/SCTP.
Q931 layer is not processed by IVPS or BALT, but transparently sent/received asSIGTRAN packets information to/from the Call Server.
Configuration data:IVPS stores the L1 activation type (per-call or permanent) for each port.When the communication with a BALT is established, IVPS sends thisinformation to BALT.
POLT
The POLT supports up to 48 POTS interfaces and integrates functions such asringing, digit detection and tone generation. The POLT provides a classical POTSinterface towards the subscriber and performs the packetization of the voice over
RTP, sending the voice directly to the network as VoIP over Ethernet.
This is the analogue Z interface connecting to a telephone set. The main commonfeatures are the following:
Interfacing at subscribers side according to the POTS analogue Z interface: Line feeding Symmetrical programmable ringing Polarity reversal Programmable line impedance with echo cancellation Overvoltage protection
Signaling events processing and communication with IVPS according to internalXLES protocol
DTMF/pulse detection/processing Caller identification services (FSK, DTMF, on-off hook) Tone generation towards subscriber side Howler tone generation Tone generation towards network side (needed for ring-back tone) Metering pulses generation
7/23/2019 7302 7330 ISAM R2 5 Product Information
24/112
1 System Overview
1-16 October 2006 Alcatel 7302 ISAM R2.5.x
Edition 02 Released 3HH-03574-AAAA-TCZZA Product Information
Ringing generation. Integrated line testing Coding (G.711 and either G.729 or G.723.1) and packetizing voice in RTP and
directly forwarding to/from packet network based on MAC/IP/UDP addresses Voice activity detection, comfort noise, packet loss concealment
Near end echo cancellation Fax/modem detection/bypass Support of relay of DTMF and some fax/modem tones by means of RFC 2833
BALT
The interface of the BALT corresponds to the U reference point of the DigitalTransmission System as defined in G.961.
The interface provides full-duplex and bit independent transmission via two wires ata net bit rate of 144 Kbit/s, a transparent 1 Kbit/s service channel and a 1 Kbit/smaintenance channel for loops and error messages on subscriber lines, plussynchronization bits.
Duplex transmission is achieved through the use of Echo Cancellation Hybrid. Withthe Echo Cancellation Hybrid method the Echo Canceller (EC) produces a replica ofthe echo of the transmitted signal that is subtracted from the total received signal. Theecho is the result of imperfect balance of the hybrid and impedance discontinuitiesin the line.
The 2B1Q encoding is applied; the symbol rate on the line is therefore 80 KBaud.
In the case of ISDN BA over IP, the functionality is split between the BALT lineboard and the IVPS board. The BALT board supports 24 ISDN BA user ports andterminates Q.921 data links; IVPS establishes a SIGTRAN communication with theASP. ASP is responsible for terminating IUA/SCTP and processing the Q.931messages.
The BALT functions are:
Line Termination for the U interface of ISDN Basic Access ITU G.961 G.711 (A,), G.729a/b, G.723.1 coding Local Echo cancellation (G.168, G.165, none) 16 ms. tail length Voice activity detection, comfort noise, packet loss concealment Configurable jitter buffer: adaptive or fixed size (per call) Automatic fax/modem detection and bypass (transparent fax and modem service) Enhanced end-to-end tone detection and generation (as per RFC 2833) Call progress tone generation: Dial Tone, Special (Information) Dial Tone, Ring
Back Tone, Congestion Tone, Busy Tone
7/23/2019 7302 7330 ISAM R2 5 Product Information
25/112
1 System Overview
Alcatel 7302 ISAM R2.5.x October 2006 1-17
Product Information 3HH-03574-AAAA-TCZZA Edition 02 Released
DTMF digit detection: when a call is in stable phase and the user sends DTMFdigits to, for example, an automatic Call Centre, the BALT must detect theDTMF.
Support for duplication of RTP streams for future Lawful Interceptionimplementation
Regarding ISDN signaling: Termination of Q921 protocol (SABME,UA, RR,..., timers, states,...) BALT establishes, releases and maintains data links with TEs as specified in Q.921.
For this, BALT controls LAPD sequence numbers, maintain Q.921 state machines,etc. There is one established data link for each TEI.
There is one data link established between BALT and IVPS. XLES for POTS istransported inside that data link.
Dynamic TEI assignment is done by BALT The ASP (through IVPS) may command the removal of a particular TEI. BALT
carries out this action and notifies it to IVPS. Also, ASP may ask for TEI status.
Integrated Line Testing
The integrated Line Testing functionality can be used by the operator in order todetect failure conditions and anticipate possible problems.
Note:Only line testing of POTS line terminations can be tested.
Tests can be performed on demand (required by an operator command).
The following test can be performed:
Electrical measurement test:The purpose of these tests is the measurement of electrical parameters. These testsdo not require customer assistance. Any or all of these tests can be invoked in thesame test request for a given user port. Electrical measurement tests are:
Foreign voltage (AC/DC): This test is measuring foreign voltage between wires. Capacitance: This test is measuring capacitance between wires. Insulating resistance: This test is measuring insulating resistance between wires. Impedance: This test is measuring the impedance between wires. Termination (M Socket detection): This test is to detect whether a phone or just a
resistance connects the line.
Feeding voltage: This test is performed measuring voltage over wires in open circuitand verifying voltage remains within thresholds.
Feeding current: This test is performed connecting a resistor loading the wires andmeasuring the current in limiting mode.
Noise level: This test is to detect abnormal noise level, e.g. crosstalk
7/23/2019 7302 7330 ISAM R2 5 Product Information
26/112
1 System Overview
1-18 October 2006 Alcatel 7302 ISAM R2.5.x
Edition 02 Released 3HH-03574-AAAA-TCZZA Product Information
Group test:This test consists of a combination of predefined electrical measurementsrequested by the OS as previous electrical measurement tests. It includes acombination of voltage, capacitance and insulating resistance measurements. Itcan be performed on ISAM-V devices in 10 s. Thirteen possible measurements
are: AC Foreign voltage: a/Earth, b/Earth and a/b DC Foreign voltage: a/Earth, b/Earth and a/b Capacitance: a/Earth with b grounded, b/Earth with a grounded and a/b Insulation resistance: a/Earth with b grounded, b/Earth with a grounded, a/b and b/a
Dial tone test:This test checks the ability of the line circuit to detect an off-hook and to checkthe provision of the dial tone from the MGC.
An off-hook condition is simulated in the NE. This off-hook must be detected bythe line circuit and is further processed by call-handling software; the MGC willthen interpret it as a real off-hook and will send a dial tone. The time is measuredand compared with a predefined threshold. Returned result is the delay to dial
tone. Howler tone test
This test lets the user know that the mike is not hooked on correctly and restoresthe user state from parking to idle after the user hooks on the mike. If the user doesnot hook on the mike, the howler tone is stopped after a predefined timeout. Thehowler tone level and frequency depend on different countries specifications.
Status monitor
This test lets the operator know the indicated users status.
Dimensioning
The tables below show the dimensioning capacities for:
IVPS: see Table 1-4 POLT: see Table 1-5 BALT: see Table 1-6
Table 1-4 IVPS Dimensioning
Description Value
Number of registered subscribers per IVPS 5000
Maximum number of controlled ISAM-V nodes 32
Number of associated POLTs 105
Number of controlling IVPS per ISAM-V shelf 1
7/23/2019 7302 7330 ISAM R2 5 Product Information
27/112
1 System Overview
Alcatel 7302 ISAM R2.5.x October 2006 1-19
Product Information 3HH-03574-AAAA-TCZZA Edition 02 Released
Table 1-5 POLT Dimensioning
Table 1-6 BALT Dimensioning
Description Value
Number of POTS lines 48
Number of DSP voice ports 48 for G.711
24 for G.729 and G.723.1.
Note: there are three ports per Vinetic 4VIP for low-bitratecodecs
Number of POLT per ISAM-V 16
Number of IP addresses per POLT 1
Note: shared by all ISAM-V line cards in an ISAM node.
Number of simultaneous ringers 7 (with blocking probability of 1.1E-5)
Number of enhanced feeding lines Up to 5 lines per POLT can be configured to work withenhanced feeding (40 mA).
Note: Enhanced feeding can be configured ONLY from line 44to line 48.
Description Value
Number of BA-ISDN ports 24
Number of supported B-channels 48
Number of BALT per ISAM-V 16
Number of IP addresses per BALT 1
Note: shared by all ISAM-V line cards in an ISAM node.
7/23/2019 7302 7330 ISAM R2 5 Product Information
28/112
1 System Overview
1-20 October 2006 Alcatel 7302 ISAM R2.5.x
Edition 02 Released 3HH-03574-AAAA-TCZZA Product Information
7/23/2019 7302 7330 ISAM R2 5 Product Information
29/112
Alcatel 7302 ISAM R2.5.x October 2006 2-1
Product Information 3HH-03574-AAAA-TCZZA Edition 02 Released
2 Software Architecture
2.1 General 2-2
2.2 7302 ISAM System Initialization 2-4
2.3 Network Management 2-6
7/23/2019 7302 7330 ISAM R2 5 Product Information
30/112
2 Software Architecture
2-2 October 2006 Alcatel 7302 ISAM R2.5.x
Edition 02 Released 3HH-03574-AAAA-TCZZA Product Information
2.1 General
Figure 2-1shows the basic software architecture of the 7302 ISAM.
Figure 2-1 Basic 7302 ISAM Architecture
The 7302 ISAM software is composed of the following five top level softwaredomains:
Platform SoftWare (SW):
Offers a robust platform upon which applications can be built, providing kerneland file system services, memory management, data management, an internalcommunication infrastructure,... Operating System (OS) dependencies areshielded by the XAPI OS shielding layer.
HardWare (HW) Wrapper SW:Offers APIs that allow to access the hardware on the board, in such a way thathardware dependencies are isolated from the application SW.
Core Services SW:Offers services that can be reused by typical applications in the 7302 ISAM, suchas Alarm Management, Performance Monitoring Handing, and so on.
Management Protocol SW:Offers the management protocols framework including Simple NetworkManagement Protocol (SNMP) / Transaction Language One (TL)1 / CommandLine Interface (CLI) management SW, transaction control management, and soon.
Applications SW:The management applications in 7302 ISAM implementing the different productservices and Management Information Bases (MIBs) of the 7302 ISAM.
NT boardsMANAGEMENT PROTOCOL
APPLICATION SOFTWARE
LIM / Server boards
HARDWARE WRAPPERS
PLATFORM SOFTWARE
incl. INT. COMMUNICATIONS SW (IOCM, RFC, sockets)
HARDWARE HARDWARE
EQUIPMENT MANAGEMENT
incl. EQPT MGNT CORE, INTERFACE MGT, INFRA MGT, ...
SERVICES
HARDWARE WRAPPERS
ITF
MGNT
ITF
MGNT
Distributed applications
7/23/2019 7302 7330 ISAM R2 5 Product Information
31/112
2 Software Architecture
Alcatel 7302 ISAM R2.5.x October 2006 2-3
Product Information 3HH-03574-AAAA-TCZZA Edition 02 Released
The application software of the 7302 ISAM exists of the following managementdomains:
Equipment managementRack/shelf/board/applique Management
Software & Database ManagementInterface Management
Metallic Test Access Management
NT 1+1 Redundancy Management
XDSL/ATMXDSL management
ATM management
Layer 2Virtual Local Area Network (VLAN) & Bridge management
Quality of Service (QoS) management
Layer 2+
multicastInternet Group Management Protocol (IGMP) management
session layer applications802.1x
Point to Point Protocol over Ethernet (PPPoE)-relay
PPPoE to Point to Point Protocol over ATM (PPPoA)-relay
DHCP-relay
Virtual Broadband Access Server (VBAS)
Layer 3PPP/PPPoE-server (termination)
Layer 3 forwarding
IPoPPPoEoA forwarding IPoA forwarding IPoEoA forwarding
AuthenticationRadius Client
Local User Authentication
Local IP Address Management
7/23/2019 7302 7330 ISAM R2 5 Product Information
32/112
2 Software Architecture
2-4 October 2006 Alcatel 7302 ISAM R2.5.x
Edition 02 Released 3HH-03574-AAAA-TCZZA Product Information
2.2 7302 ISAM System Initialization
GeneralThis section describes the initialization of the 7302 ISAM.
After the SHub subsystem and the LT shelf subsystem are powered up, the bootsequence starts for each subsystem.
SHub Subsystem Initialization
While booting, the SHub subsystem retrieves all necessary parameters from memoryor from pre-configured defaults. A pre-defined OAM VLAN with VLAN ID(IC-VLAN= 4094) is fixed and cannot be used in the connected network because thevalue 4094 is reserved and may not be used externally. This internal OAM VLAN isalso pre-defined in the NT-LT initialisation. This VLAN is used for the software
download to the LTs and the configuration of the LTs.
If a configuration database was saved, and the SHub subsystem was set to restore thisconfiguration before the last system down, the SHub subsystem will retrieve thisconfiguration.
The SHub subsystem is now operational.
For more information, refer to the Operations and Maintenance Using CLI.
LT Shelf Subsystem Initialization
Since the NT board is the system manager, it has the control over the system initphases of the LT shelf subsystem and is responsible for the sequencing of theinitialization phases of the NT board and the rest of the 7302 ISAM. This is incontrast to the SHub subsystem which is initialized independently. The initializationof the LTs and the SHub subsystem happen parallel. However as long as the SHubsubsystem is not up, the NT will not establish communication with the LTs. The NTsoftware can check if the SHub subsystem is alive.
The LT shelf subsystem initialization consists of the following phases:
Local NT initialization System initialization Enable external 7302 ISAM management
Local NT Initialization
The following phases are identified for the local NT initialization:
Boot phase Overall SoftWare (OSW) startup Initialization phase Restore data from non-volatile memory
In this phase the LT boards boot and wait for the NT board to get their OSW.
7/23/2019 7302 7330 ISAM R2 5 Product Information
33/112
2 Software Architecture
Alcatel 7302 ISAM R2.5.x October 2006 2-5
Product Information 3HH-03574-AAAA-TCZZA Edition 02 Released
System Initialization
In the first phase of the system initialization, the NT board detects the LT boards, theACU and the appliques (HW) and downloads the appropriate SW to the LT boards.
The LT boards start up with their SW and perform their specific initialisations.
After these initialisations, each LIM board sends a signal to the NT board. Thesecond phase of the system initialization begins when the NT board receives thissignal. Now the NT board configures each LT board.
Enable External 7302 ISAM Management
When the LT boards are configured, the 7302 ISAM management is enabled on theNT board and the 7302 ISAM indicates that the initialization is fully complete andthe system is operational.
Note:For more information about the initialization and startup of the 7302 ISAMplease refer to the Operations and Maintenance Using CLI.
7/23/2019 7302 7330 ISAM R2 5 Product Information
34/112
2 Software Architecture
2-6 October 2006 Alcatel 7302 ISAM R2.5.x
Edition 02 Released 3HH-03574-AAAA-TCZZA Product Information
2.3 Network Management
Figure 2-2shows how the 7302 ISAM can be managed in a network.
Figure 2-2 7302 ISAM Network Management
The remote Craft Terminal (CT) uses TL1 commands or Command Line Interface(CLI) commands. TL1 is used for pre-provisioning of the NT board. CLI is used tomanage both the SHub subsystem as the NT board.
Figure 2-3shows the management topology for the two subsystems of the7302 ISAM.
Figure 2-3 7302 ISAM Management Topology
Note:If the 7302 ISAM is configured to have only one public IP address, then thedirect SNMP management interface to the SHub is no longer available. The SHubwill then be managed through the SNMP interface of the NT.
LIM
LIM
LIM
EMAN
EMS CT
RS232
100/1000Base-T
Network Ports
Remote CT
Management Flowto Cascade ISAM
ISAM
NT controller
SHub
CLI (via Telnet)TL1 (via UDP-login)
TL1 Craft Terminal
Mapper
Appl icat ion Code Appl icat ion Code
Mapper
NT Controller / LSM SHub
SNMP
TL1
SNMP
CLI Craft Terminal
ISAM
CLI
SNMP based Manager
(e.g. 5523 AWS)
LT Shelf
EMS
7/23/2019 7302 7330 ISAM R2 5 Product Information
35/112
2 Software Architecture
Alcatel 7302 ISAM R2.5.x October 2006 2-7
Product Information 3HH-03574-AAAA-TCZZA Edition 02 Released
The NT Controller and the SHub subsystem each contain a separate SNMP agent.The NT Controller / LIMs and the SHub subsystem can be managed via an EMS.
It is also possible to use local TL1 or CLI craft terminal on the NT board to managethe LTs.
An integrated CLI approach is implemented on the NT board using an CLI agent.This agent implements CLI commands for the NT Controller / LIMs and the SHubsubsystem. However, there is no semantical integration.
Table 2-1shows an overview of the managers which are involved:
Table 2-1 Manager Overview
Note: External OAM VLAN
The SHub subsystem supports inband management. This happens through adedicated VLAN, which must be configured (if different than 4043) on both theSHub subsystem as on the NT.
Type Description
EMS (for example,5523 AWS)
Element Management System (EMS) based on SNMP. The AlcatelWorkStation (5523 AWS) is commonly used.
CT Craft Terminal using TL1 commands or Command Line Interface (CLI)commands.
7/23/2019 7302 7330 ISAM R2 5 Product Information
36/112
2 Software Architecture
2-8 October 2006 Alcatel 7302 ISAM R2.5.x
Edition 02 Released 3HH-03574-AAAA-TCZZA Product Information
7/23/2019 7302 7330 ISAM R2 5 Product Information
37/112
Alcatel 7302 ISAM R2.5.x October 2006 3-1
Product Information 3HH-03574-AAAA-TCZZA Edition 02 Released
3 Subracks
3.1 Introduction 3-2
3.2 General 3-2
3.3 XD Splitterless Subrack (ALTS-T) 3-3
3.4 XD Splitter Subrack (ASPS-A) 3-8
3.5 XD Standard Splitter Subrack (ASPS-C) 3-11
3.6 XD-Combo300 Subrack (ALTS-U) 3-14
3.7 Weight of the Different Components 3-19
7/23/2019 7302 7330 ISAM R2 5 Product Information
38/112
7/23/2019 7302 7330 ISAM R2 5 Product Information
39/112
3 Subracks
Alcatel 7302 ISAM R2.5.x October 2006 3-3
Product Information 3HH-03574-AAAA-TCZZA Edition 02 Released
3.3 XD Splitterless Subrack (ALTS-T)
The eXtreme Density (XD) splitterless (XD-LT) subrack accommodates XD unitsand several units that also fit other subrack types.
The XD-LT subrack supports LIMs serving up to 48 DSL lines (XD).
The XD-LT subrack has a backplane.
The XD-LT subrack is supported from R2.0 on.
Mnemonic
The mnemonic is ADSL Line Termination Subrack version T (ALTS-T).
Dimensions
Figure 3-1shows a front view (fan unit and front cover are not included).
Figure 3-1 Inside View of XD-LT Subrack
Table 3-2gives overall dimensions.
Table 3-2 XD-LT Subrack Density and Dimensions
The XD-LT subrack fits into conventional SI transmission racks (600 mm width and300 mm depth).
Subrack Type Mnemonic Density/ DSL Lines Height Width Depth
XD-LT ETSI ALTS-T Extreme Density/768 DSL lines
750 mm 530 mm 285 mm
7/23/2019 7302 7330 ISAM R2 5 Product Information
40/112
3 Subracks
3-4 October 2006 Alcatel 7302 ISAM R2.5.x
Edition 02 Released 3HH-03574-AAAA-TCZZA Product Information
Location
The XD-LT subrack can be installed in a Central Office (CO) or a ControlledEnvironment Vault (CEV) and can be deployed in remote cabinets requiringextended temperature range operation.
Areas and Slot Positions
Figure 3-2shows the layout of the XD-LT subrack.
Figure 3-2 Areas and Slot Positions in XD-LT Subrack
The XD-LT subrack has three areas:
TheLine Termination (LT)area orLine Server Module (LIM)area is 450 mmhigh and can house 420 mm x 220 mm plug-in units.
The Connector areaabove the LT area is 250 mm high and is dimensioned tohouse two rows of CHAMP connectors. It provides housing for NT I/O, filtersand connectors for power and other interface connection and space for cablerouting.
The Fan areabelow the LT area is 50 mm high and can house a separate fan unit.
ACU
NT
A
NT
B
LT
01
P1
Crossover slot pairs
P2 P3 P4 P5 P6 P7 P8
Connector area
Line Termination area
Fan area
LT
02
LT
03
LT
04
LT
05
LT
06
LT
07
LT
08
LT
09
LT
10
LT
11
LT
12
LT
13
LT
14
LT
15
LT
16
EXT
TRU
POWER
NTI/O
RCFT
7/23/2019 7302 7330 ISAM R2 5 Product Information
41/112
3 Subracks
Alcatel 7302 ISAM R2.5.x October 2006 3-5
Product Information 3HH-03574-AAAA-TCZZA Edition 02 Released
Board Types
The XD-LT subrack can accommodate the following units (Figure 3-2):
one Alarm Control Unit (ACU) plug-in board two Network Termination (NT) boards
up to 16 LIMs:Splitters for the xDSL LIMs can not be mounted in the XD-LT subrack and willbe put in a separate subrack.
one NT I/O applique:This applique is a full size board which plugs into both NTIO connectors, locatedhigh in the DSL cabling area of the subrack.
one SMAS board:This small board serves as a subrack identification resource. It is plugged into thebackplane and is delivered as an integral part of the subrack.
Notes:
No PWR I/O board is developed for the XD-LT subrack. The power connectorsare available in the connector area.
No specific Termination Plugs are supported for R2.5.
Restrictions
The following restrictions apply:
The XD-LT subrack is not equipped with a TEST/SPARE bus. When the 1:N LTredundancy and/or MTA functionality needs to be supported, the necessaryprovisions need to be available in the connected splitter device (refer to section4.1.2).
The XD-LT subrack will not be ready to support 72-line boards.
1+1 NT Redundancy
NT redundancy is supported from R2.2 onwards (HW & SW). NT redundancy issupported in the following boards:
ECNT-A ECNT-C CB
1+1 LIM Redundancy
The backpanel is already provisioned to support the 1+1 LIM redundancy. Thenecessary will have to be mounted in the splitter subrack (XD-SP) since appliques
cannot be mounted in the XD-LT subrack itself.1+1 LIM redundancy is not a supported R2.x feature.
1:N LIM
The 1:N redundancy of the LIMs is not supported in the XD-LT subrack itself sinceno TEST/SPARE bus is available. When this functionality is required, the necessaryprovisions need to be available in the connected splitter device.
1:N LIM redundancy is not a supported R2.x feature.
7/23/2019 7302 7330 ISAM R2 5 Product Information
42/112
3 Subracks
3-6 October 2006 Alcatel 7302 ISAM R2.5.x
Edition 02 Released 3HH-03574-AAAA-TCZZA Product Information
Overview of Supported Units
Table3-3gives an overview of the supported plug-in units in the XD-LT subrack forR2.5.x. Refer to Figure 3-2for the layout and slot positions.
For detailed information about units, refer to the UDS. Appendix A gives the usedmnemonics.
Table 3-3 Supported Units in XD-LT Subrack - R2.5.x
.xNotes(1) For non Central Office (Class 3.1E of ETS 300 119-1) environment deployment, check with Alcatel
whether Outdoor Cabinet LT (OD-LT) boards have to be used.
Slot Board
Type
Corresponding Applique Description
Type Position
NT A ECNT-A
ECNT-C CA
ECNT-C CB
ECNC-A
ECNC-B
NT I/O Hardware introduced in R2.0;SHub integrated on board.
Working position (simplex or in NT1+1 pair)
NT B ECNT-A
ECNT-C CA
ECNT-C CB
-- -- Standby position in NT 1+1 Pair(Empty in simplex configuration).
ACU AACU-C
AACU-E
-- -- Alarm Control Unit
LIM slot
(01 - 16)
EALT-A PSPS-A/B/C Splittersubrack
48 ADSL2 POTS interfaces
EBLT-A
EBLT-C
EBLT-E
EBLT-J
EBLT-K
48 ADSL2/2+ POTS interfaces
EBLT-D
EBLT-F
EBLT-L
PSUS-A 48 ADSL2/2+ ISDN interfaces
EVLT-C VSPB-A 24 VDSL POTS interfaces
EVLT-D VSUB-A 24 VDSL ISDN interfaces
POLT-A PSPS-A/B/C 48 POTS line interfacesCombo function (POLT-A + xDSLLT) takes two slots in subrack
SMLT-J CTAB-C
CTAS-C
24 SHDSL interfaces
IVPS-A
IVPS-B
-- ISAM Voice Package Server
EBAS-A --
BALT-A PSUS-A 24 ISDN BA interfaces
Combo function (BALT-A + xDSLLT) takes two slots in subrack
Fan area AFAN-H -- -- Fan unit. Part of the subrack.
Backplane SMAS-A -- -- Plugged into the backplane.
Integral part of the subrack.Stores systems MAC addressesand ASAM ID (based onboardserialId).
7/23/2019 7302 7330 ISAM R2 5 Product Information
43/112
3 Subracks
Alcatel 7302 ISAM R2.5.x October 2006 3-7
Product Information 3HH-03574-AAAA-TCZZA Edition 02 Released
Dummy Front Panels
The following dummy front panels are available for XD-LT subracks:
for NT slots: front panel 3FE 22626 AAAA for LT slots: front panel 3FE 22625 AAAA.
Powering
Power cables are directly connected to the power filters in the connector area.
Fan Unit
One fan unit (AFAN-H) provides forced air cooling in the subrack. The fan unit is afield replaceable unit in the subrack fan area, it plugs directly into the backplane.There are two variants, one with dustfilter and one without dustfilter. The fan unit ofthe subrack in the lowest rack position must always contain a dustfilter (seeRackConfiguration).
7/23/2019 7302 7330 ISAM R2 5 Product Information
44/112
3 Subracks
3-8 October 2006 Alcatel 7302 ISAM R2.5.x
Edition 02 Released 3HH-03574-AAAA-TCZZA Product Information
3.4 XD Splitter Subrack (ASPS-A)
The XD-LT subrack is splitterless. Therefore, the splitter appliques for the LT boardsneed to be housed in a separate subrack, the XD splitter (XD-SP) subrack.
The XD-SP subrack is supported from R2.0 on.
Mnemonic
The mnemonic is ADSL SPlitter Subrack version A (ASPS-A).
Dimensions
Figure 3-3shows a front view.
Figure 3-3 Inside View of XD-SP Subrack
Table 3-4gives the overall dimensions.
Table 3-4 XD-SP Subrack Density and Dimensions
The XD-SP subrack fits into conventional SI transmission racks (600 mm width and300 mm depth).
Subrack Type Mnemonic Density/ DSL Lines Height Width Depth
XD-SP ETSI ASPS-A Extreme Density/768 DSL lines
785 mm 465 mm 290 mm
7/23/2019 7302 7330 ISAM R2 5 Product Information
45/112
3 Subracks
Alcatel 7302 ISAM R2.5.x October 2006 3-9
Product Information 3HH-03574-AAAA-TCZZA Edition 02 Released
Location
The XD-SP subrack can be installed in a CO or a CEV and can be deployed in remotecabinets requiring extended temperature range operation.
Areas and Slot PositionsFigure 3-4shows the areas and slot positions.
Figure 3-4 Areas and Slot Positions in XD-SP Subrack
The XD-SP subrack has three areas:
The Top Connectorarea provides connectors for Alarm interface and ADSLconnection (ADSL 25 to ADSL 48) and space for routing ADSL cables.
The Splitter (SP)area is 520 mm high and can house 520 mm x 220 mm plug-inunits (PSPS).
TheBottom Connectorarea provides filters and connectors for power and ADSLconnection (ADSL 01 to ADSL 24) and space for routing ADSL cables.
Board Types
The XD-SP subrack can accommodate the following units (Figure 3-4):
one TAUS test access unit up to 16 splitter boards (PSPS or PSUS):
one per equipped LIM in the XD-LT subrack.
AP01
AP02
AP03
AP04
AP05
AP06
AP07
AP08
AP09
AP10
AP11
AP12
AP13
AP14
AP15
AP16
AP01
TAUS
PWR
AP02
AP03
AP04
AP05
AP06
AP07
AP08
AP09
AP10
AP11
AP12
AP13
AP14
AP15
AP16
AP01
AP02
AP03
AP04
AP05
AP06
AP07
AP08
AP09
AP10
AP11
AP12
AP13
AP14
AP15
AP16
AP01
AP02
AP03
AP04
AP05
AP06
AP07
AP08
AP09
AP10
AP11
AP12
AP13
AP14
AP15
AP16
Bottom connector area
ALM Top connector area
Splitter area
7/23/2019 7302 7330 ISAM R2 5 Product Information
46/112
3 Subracks
3-10 October 2006 Alcatel 7302 ISAM R2.5.x
Edition 02 Released 3HH-03574-AAAA-TCZZA Product Information
LT Redundancy and Metallic Test Access Support
The XD-SP subrack provides a Test/Spare bus on the backpanel for the support of1:N LT redundancy and Metallic Test Access (MTA).
A dedicated slot (TAUS) is foreseen for a Test-I/O Applique. A SPI bus connects this
slot with the 16 splitter slots to allow control of the relays on the splitter boards.
Overview Supported Units
Table 3-5gives an overview of the supported plug-in units in the XD-SP subrack forR2.5.x. These units must be used in conjunction with the LT boards in the XD-LTsubrack. Refer to Figure 3-4for layout and slot positions.
For detailed information about units, refer to the UDS. Appendix A gives the usedmnemonics.
Table 3-5 Supported Units in XD-SP Subrack - R2.5.x
Dummy Front Panels
When MDF cabling is already foreseen for not-installed units, the MDF connectors
must be fixed on dummy front panels.
The following dummy front panels are available for XD-SP subracks:
front panel 3EC 37714 AAAA
Powering
Power cables are directly connected to backplane terminals in the bottom connectorarea.
Slot Board Type Description
Splitter slot
(01-16)
PSPS-A
PSPS-B
PSPS-C
Passive POTS splitter. ADSL2+ compatible.
PSUS-A Passive POTS/ISDN splitter. ADSL2+ compatible.
CTAS-C Cut-through applique for SHDSL.
7/23/2019 7302 7330 ISAM R2 5 Product Information
47/112
3 Subracks
Alcatel 7302 ISAM R2.5.x October 2006 3-11
Product Information 3HH-03574-AAAA-TCZZA Edition 02 Released
3.5 XD Standard Splitter Subrack (ASPS-C)
The XD-LT subrack is splitterless. Therefore, the splitter appliques for the LT boardsneed to be housed in a separate subrack. The XD-PSP subrack is a cost-improvedversion of the XD-SP subrack. The main characteristics of this new subrack type are:
The subrack has no backplane will be equipped (no MTA support, no LTredundancy support).
The subrack can house up to 16 xDSL line boards. Each board is able to handle48 lines.
The subrack can be mounted in the existing ETS rack frame of an XD Modularsystem (above the XD-LT subrack) or in a standard 19 rack. By re-orienting themounting brackets, the subrack can be mounted in frames.
The XD-PSP subrack is supported from R2.2 on.
Mnemonic
The mnemonic is ADSL SPlitter Subrack version C (ASPS-C).
Dimensions
Figure 3-5shows a front view.
Figure 3-5 View of XD-PSP Subrack
Table 3-6gives the overall dimensions.
Table 3-6 XD-PSP Subrack Density and Dimensions
Subrack Type Mnemonic Density/ DSL Lines Height Width Depth
XD-PSP ETSI ASPS-C Extreme Density/768 DSL lines
600 mm
19
(fits 600 mm rack byusing brackets)