2
Function: 36 Tyco Electronics / www.tycoelectronics.com / Factory Direct Technical Support: 800-253-4560, ext. 2023 (U.S., Canada, Mexico) or 805-220-2020, ext. 2023 (International) ANSI/IEEE C37.90-1978 UL file No. E58048 CSA file No. LR61158 Application: These relays are designed for automatic paralleling (synchronizing) of generators. The relays sense the phase angle displacement and the amplitude differ- ence between two voltages and permit paralleling only when both voltages are equal and in phase. A short time delay is provided to assure that the frequencies are essentially the same at the moment of paralleling. The basic series is designed to parallel two or more energized AC generators. The “Dead Bus” type provides paralleling of AC generators to the main bus. They permit electrical connection of an energized generator to an un-energized line (Dead Bus). If the bus is energized, connection of the generator to the bus is permitted only when both are synchronized. Paralleling Relays PRODUCT SPECIFICATIONS WILMAR™ Protective Relays – 1800 Series Part Number Sensing Voltage ............................. Line Frequency ............................... Pick-Up Adjustment ....................... Time Delay ..................................... Output Contacts ............................. 1800 Series 120 V, 230 V, 277 V, 380 V, 460 V, 575 V, & 415 V 50-500 Hz External adjustment for field sensing of 10-30% of nominal input voltage. (Vertical voltage differential of 6 to 18 electrical degrees). Fixed @ 60 milliseconds is provided to assure that the frequencies of both input lines are sufficiently close to permit paralleling within the preset window. One set N.O., one set N.C. 5 amp resistive at 120 VAC or 28 VDC A. 3 Phase, 4 Wire System Connect phase "A" of LINE 1 to terminal 1 Connect phase "A" of LINE 2 to terminal 3 Connect the neutrals to terminals 2 & 4 B. 3 Phase, 3 Wire or 1 Phase, 2 Wire System Connect phase "A" of LINE 1 to terminal 1 Connect phase "B" of LINE 1 to terminal 2 Connect phase "A" of LINE 2 to terminal 3 Connect phase "B" of LINE 2 to terminal 4 Consult factory for additional models and options. 25 11 /64" DIA. 4 MTG. HOLES 3 4 4 7 /8 4 1 /2 3 7 /8 4 5 /8 #6 - 32 STUDS 6 PLACES Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm.

A988C6068EE33B0ABE465CA9E7BD0C70FFCC03E9

Embed Size (px)

Citation preview

Function:

36 Tyco Electronics / www.tycoelectronics.com / Factory Direct Technical Support: 800-253-4560, ext. 2023 (U.S., Canada, Mexico) or 805-220-2020, ext. 2023 (International)

• ANSI/IEEE C37.90-1978• UL file No. E58048• CSA file No. LR61158

Application:These relays are designed for automatic paralleling(synchronizing) of generators. The relays sense thephase angle displacement and the amplitude differ-ence between two voltages and permit parallelingonly when both voltages are equal and in phase. Ashort time delay is provided to assure that thefrequencies are essentially the same at the momentof paralleling. The basic series is designed to paralleltwo or more energized AC generators. The “DeadBus” type provides paralleling of AC generators tothe main bus. They permit electrical connection of anenergized generator to an un-energized line (DeadBus). If the bus is energized, connection of thegenerator to the bus is permitted only when both aresynchronized.

Paralleling Relays

PRODUCT SPECIFICATIONS

WILMAR™ Protective Relays – 1800 Series

Part NumberSensing Voltage .............................

Line Frequency ...............................Pick-Up Adjustment .......................

Time Delay .....................................

Output Contacts .............................

1800 Series120 V, 230 V, 277 V, 380 V, 460 V, 575 V, & 415 V

50-500 HzExternal adjustment for field sensing of 10-30% ofnominal input voltage. (Vertical voltage differential of 6to 18 electrical degrees).

Fixed @ 60 milliseconds is provided to assure that thefrequencies of both input lines are sufficiently close topermit paralleling within the preset window.

One set N.O., one set N.C.5 amp resistive at 120 VAC or 28 VDC

A. 3 Phase, 4 Wire SystemConnect phase "A" of LINE 1 to terminal 1Connect phase "A" of LINE 2 to terminal 3Connect the neutrals to terminals 2 & 4

B. 3 Phase, 3 Wire or 1 Phase, 2 Wire SystemConnect phase "A" of LINE 1 to terminal 1Connect phase "B" of LINE 1 to terminal 2Connect phase "A" of LINE 2 to terminal 3Connect phase "B" of LINE 2 to terminal 4

Consult factory for additional models and options.

25

11/64" DIA.4 MTG. HOLES

3

4

4 7/8

4 1/2

3 7 /8

4 5 /8

#6 - 32 STUDS6 PLACES

Note: Dimensions in inches. Multiply values by 25.4 for dimensions in mm.

Function:

Tyco Electronics / www.tycoelectronics.com / Factory Direct Technical Support: 800-253-4560, ext. 2023 (U.S., Canada, Mexico) or 805-220-2020, ext. 2023 (International) 37

Paralleling Relays

Selection Guide(Typical Applications)

Output Contact Options: 1. Two Form A. (Add -A to Model Number)2. Two Form B. (Add -B to Model Number)

egatloVgnisneS 0081seireSrotareneGotrotareneG rotareneGotrotareneG rotareneGotrotareneG rotareneGotrotareneG rotareneGotrotareneG

BD0081seireSsuBotrotareneG suBotrotareneG suBotrotareneG suBotrotareneG suBotrotareneG

BDD0081seireSsuBotsuB suBotsuB suBotsuB suBotsuB suBotsuB

srotarenegowtfognilellarapstimrePdna"enil-no"erayehtnehwylno

esahpnidnalauqeerasegatlovrieht)dezinorhcnys(

timrepotdesuyllamroNaotrotarenegafognilellarap

enilhtob)a(:nehwsub,esahpnidnalauqeerasegatlov

sirotarenegehtnehw)b(:ro"daed"sisubehtdna"enil-no"

rewopowtfognilellarapstimrePenilhtob)a(:nehw)sesub(senil

:ro,esahpnidnalauqeerasegatlovehtdna"toh"sisubrehtienehw)b(

"daed"sisubrehto

stloV021 X0181 XBD0181 XBDD0181

stloV032 X0281 XBD0281 XBDD0281

stloV083 X0381 XBD0381 XBDD0381

stloV064 X0481 XBD0481 XBDD0481

stloV575 X0581 XBD0581 XBDD0581

stloV514 X0681 XBD0681 XBDD0681

stloV772 X0781 XBD0781 XBDD0781

noitidnoC 0081seireSstcatnoC stcatnoC stcatnoC stcatnoC stcatnoC

BD0081seireSstcatnoC stcatnoC stcatnoC stcatnoC stcatnoC

BDD0081seireSstcatnoC stcatnoC stcatnoC stcatnoC stcatnoC

dezigrenEtoN

dezigrenE dezigrenE dezigrenE dezigrenE dezigrenE.hcnyS .C.N .O.N .C.N .O.N .C.N .O.N

11eniL X

nepO esolC nepO esolC nepO esolC2eniL X seY

21eniL X oN

esolC nepO esolC nepO esolC nepO2eniL X oN

31eniL X

esolC nepO nepO esolC nepO esolC2eniL X

41eniL X

esolC nepO esolC nepO esolC nepO2eniL X

51eniL X

esolC nepO esolC nepO nepO esolC2eniL X