Biosorp Tech MYT 2012 -Contoh BAST

  • Upload
    awan

  • View
    13

  • Download
    0

Embed Size (px)

Citation preview

  • Biosorp Technology/PAU Building 6th Floor/ Institut Teknologi Bandung/+6281313938850

    Bandung, 1 September 2014

    Nomor : 01/BAST-BT-MANDIRI/IX/2014

    Perihal : Berita Acara Serah Terima

    Lampiran : 1 (satu) Lembar

    Kepada YTH

    Bapak Nixon LP Napitupulu

    Corporate Secretary

    PT Bank Mandiri (Persero), Tbk

    Plaza Mandiri 21th Floor

    Jalan Jendral Gatot Subroto Kav.36 38 Jakarta 12190

    Dengan Hormat,

    Berdasarkan Nota Kesepakatan Hibah Modal Proyek Nomor : FST.CSC/CSR.038/2013

    tanggal 15 Juli 2013 antara PT Bank Mandiri (Persero), Tbk dengan Tim Ganesha Clean

    Water a/n Andini Warih Wedaringtyas Pemenang Pertama Mandiri Young Technopreneur

    2012 kategori Air. Terkait telah diselesaikannya pekerjaan pada Tahap I dengan hasil

    Prototype Biosorp Technology yang telah mendapatkan rekomendasi oleh kedua Mentor,

    kami mengajukan Berita Acara Serah Terima Pekerjaan.

    Atas perhatian Bapak, kami mengucapkan Terima Kasih

    Hormat kami,

    Andini Warih Wedaringtyas

    Tim Ganesha Clean Water

  • Biosorp Technology/PAU Building 6th Floor/ Institut Teknologi Bandung/+6281313938850

    BERITA ACARA SERAH TERIMA PEKERJAAN

    TAHAP I MANDIRI YOUNG TECHNOPRENEUR 2012

    PEMENANG I KATEGORI AIR

    Pada hari ini Senin tanggal 1 (satu) bulan September tahun 2014, bertempat di PLAZA

    MANDIRI Lantai 21, Jalan Jendral Gatot Subroto Kav.36 38 Jakarta, telah diserah

    terimakan spesifikasi prototype Biosorp Technology (terlampir) sebagai hasil akhir

    pekerjaan Tahap I Hibah Modal Proyek Pemenang Mandiri Young Technopreneur 2012

    Kategori Air.

    Pihak I Pihak II

    Bapak Nixon LP Napitupulu Andini Warih Wedaringtyas

    Corporate Secretary Project Manager

    PT Bank Mandiri (Persero), Tbk Ganesha Clean Water

    Dengan telah ditandatanginya Berita Acara Serah Terima Pekerjaan ini maka sesuai Nota

    Kesepakatan Hibah Modal Proyek Nomor : FST.CSC/CSR.038/2013 tanggal 15 Juli 2013

    selanjutnya dinyatakan bahwa Pihak II (Kedua) telah menyelesaikan kewajiban pekerjaan

    Tahap I yaitu penyempurnaan produk Biosorp Technology untuk penyediaan air bersih.

    Demikian Berita Acara Serah Terima Pekerjaan ini dibuat.

    Jakarta, 1 September 2014

    Pihak I Pihak II

    Bapak Nixon LP Napitupulu Andini Warih Wedaringtyas

    Corporate Secretary Project Manager

    PT Bank Mandiri (Persero), Tbk Ganesha Clean Water

  • Biosorp Technology/PAU Building 6th Floor/ Institut Teknologi Bandung/+6281313938850

    Product Data Sheet

    BIOSORP-TECH 2.0 Alginate Based Media

    A biosorbent for removal Iron (Fe), Manganese (Mn), Nickel (Ni) and Zinc (Zn) and other metals

    Typical Physical,

    Chemical and

    Biological

    Properties

    Product Type granulated /beads

    Particle Size Range mm 1

    Mass (each beads) g 0,17

    Sodium Alginate content % 45

    Specific Surface Area m2/g 458,82

    Microorganism specified Bacillus subtilis sp 1

    Saccharomyces cerevisiae sp 1

    Microorganism content % 55

    Typical

    Properties and

    Applications

    BIOSORP-TECH 2.0 Alginate based media is an easy to use granular beads with strong affinity for Iron (Fe), Manganese (Mn), Nickel (Ni), Zinc (Zn) and other metals. This distinct biosorbent is designed for regenerative applications. The inherently high adsorptive capacity based bio chemical technology has been formulated into a mechanically stable granulation suitable for use in a broad range of potable water applications.

    Recommended

    Operating

    Conditions

    Flow Direction High Flow

    Minimum Bed Depth 10 cm

    Service Rate 100 mL/s or 0,36 m3/hour

    Minimum Volume 1,7 dm3

    Minimum Mass 1,18 kg

    % Removal Metal 70%

    Qmaks 5gr/kg

    RESTRICTED can not be shared with anyone Ganesha Clean Water/Biosorp Technology

    09/2014 Rev.0 Page 1 of 7

  • Biosorp Technology/PAU Building 6th Floor/ Institut Teknologi Bandung/+6281313938850

    Figure 1 Comparative Result of Iron (Fe) Removal

    Figure 2 Comparative Result of Manganese (Mn) Removal

    Figure 3 Comparative Result of Zinc (Zn) Removal

    Page 2 of 7 RESTRICTED can not be shared with anyone Ganesha Clean Water/Biosorp Technology

    09/2014 Rev.0

  • Biosorp Technology/PAU Building 6th Floor/ Institut Teknologi Bandung/+6281313938850

    Figure 4 Metal Absorption Comparative Result using BIOSORP-TECH 2.0

    Figure 5 Langmuir-Isoterm Curve of Nickel (Ni) Absorption using BIOSORP-TECH 2.0

    Figure 6 Langmuir-Isoterm Curve of Manganese (Mn) Absorption using BIOSORP-TECH 2.0

    Page 3 of 7 RESTRICTED can not be shared with anyone Ganesha Clean Water/Biosorp Technology

    09/2014 Rev.0

  • Biosorp Technology/PAU Building 6th Floor/ Institut Teknologi Bandung/+6281313938850

    Figure 7 Langmuir-Isoterm Curve of Iron (Fe) Absorption using BIOSORP-TECH 2.0

    Figure 8 Langmuir-Isoterm equation of Nickel (Ni) Absorption using BIOSORP-TECH 2.0

    Figure 9 Langmuir-Isoterm equation of Manganese (Mn) Absorption using BIOSORP-TECH 2.0

    Page 4 of 7 RESTRICTED can not be shared with anyone Ganesha Clean Water/Biosorp Technology

    09/2014 Rev.0

  • Biosorp Technology/PAU Building 6th Floor/ Institut Teknologi Bandung/+6281313938850

    Figure 10 Langmuir-Isoterm equation of Iron (Fe) Absorption using BIOSORP-TECH 2.0

    Figure 11 Iron (Fe) Absorption using BIOSORP-TECH 2.0 on variation of flowrate

    Figure 12 Manganese (Mn) Absorption using BIOSORP-TECH 2.0 on variation of flowrate

    Page 5 of 7 RESTRICTED can not be shared with anyone Ganesha Clean Water/Biosorp Technology

    09/2014 Rev.0

  • Biosorp Technology/PAU Building 6th Floor/ Institut Teknologi Bandung/+6281313938850

    Figure 13 Zinc (Zn) Absorption using BIOSORP-TECH 2.0 on variation of flowrate

    Figure 14 copper (Cu) Absorption using BIOSORP-TECH 2.0 on variation of flowrate

    Figure 15 Removal Percentage of Metal Absorption using BIOSORP-TECH 2.0 on variation of flowrate

    Page 6 of 7 RESTRICTED can not be shared with anyone Ganesha Clean Water/Biosorp Technology

    09/2014 Rev.0

  • Biosorp Technology/PAU Building 6th Floor/ Institut Teknologi Bandung/+6281313938850

    Figure 16 Desorption of Metal Absorption using BIOSORP-TECH 2.0

    Handling

    Precaution

    Before using this product, consult the Material Safety Data Sheet (MSDS)/Safety Data Sheet (SDS) for details on product hazards, recommended handling precautions and product storage

    Storage

    Store products in tightly closed original containers at temperatures recommended on the product label.

    Page 7 of 7 RESTRICTED can not be shared with anyone Ganesha Clean Water/Biosorp Technology

    09/2014 Rev.0