Upload
luis-cervantes-barradas
View
240
Download
0
Embed Size (px)
Citation preview
8/9/2019 Bomba Haskel..
1/24
PERF ORM
AN CE •
Q UALI TY • RELI ABI LI TY
P N E U M A T I C D R I V E N L I Q U I D P U M P S
8/9/2019 Bomba Haskel..
2/24
Welco me to Haske l
Haskel is an international organization offering a worldwide service through
the Haskel group of companies and factory trained distributors. The Haskel
group is headquartered in Burbank, California, with facilities throughout the
world. We have built an enviable reputation for quality based on high pressure
fluid and gas handling equipment.
In addition to offering a comprehensive range of pneumatic driven liquid
pumps, air amplifiers, pneumatic and hydraulic driven gas boosters, high
pressure valves, fittings and accessories, we custom design and build power
pacs and test rigs. Our continued investment in technology ensures that
Haskel will stay at the leading edge of high pressure technology.
This brochure introduces our pneumatic driven liquid pump range. Technical
details and advice on any of the products shown is available on request.
We are here to solve your problems. Just give us a call at 818-843-4000 or visit
our website at www.haskel.com for more information or to locate a distributor.
• Safe pneumatic operation – no heat, ame or spark risk
• Up to 100000 psi (7000 bar) capability
• Innitely variable cycling speed
• Stall feature at pre-determined pressure to hold that pressure
without consuming power
• Problem-free stop/start applications
• Easily automated – many modication and control options
• Suitable for most liquids and liqueed gases
• Alternative gas drive options – sour gas, natural gas,
boil off gases, nitrogen
• No need for air line lubrication – saves costs and
prevents contamination
• Robust, reliable, compact and easy to maintain proven design
• Unbalanced cycling spool provides immediate response to
pressure changes
• Also available in standard, or custom built power pac
configurations
• Excellent worldwide service for spares and repairs
• Can be manufactured to meet API 675, ATEX, CE and NACE
Why Use Haskel Pneumat ic Dr iven Pumps?
Our pumps offer many advantages over electrically driven pumps:
Appl ica t ions
i n c l u d e :
• Pressure testing
• Work holding/power clamping
• Jacking/lifting
• Valve actuator control
• Hydraulic cylinder actuation
• Press safety overload devices
• Roller tensioning
• Metering
• Precision lubrication and
spraying
• Liquied gas transfer
www.haskel.com
8/9/2019 Bomba Haskel..
3/24www.haskel.com
P r essu r e an d F l o w o n D em an d
This guide will help you to pre-select the pump ideally suited
for your application. If you have specific questions, however,
we urge you to provide us with details of the duties you require
from the pump, available air/gas drive pressure, and pressure/
flow requirements, and we will recommend a model and any
corresponding accessories.
O u t p u t H o r sep o w er R a t i n g s
The pumps are categorized on their horsepower ratings (see
pages 6-7). These are approximate and peak at 100 psi (7
bar), assuming adequate drive air, pressure and volume. Peak
horsepower is at about 75% nominal ratio x air drive pressure, i.e.
100:1 pump @ 100 psi air drive peaks at 100 x 100 = 10000 x 0.75 psi
= 7500 psi (517 bar) hydraulic pressure.
Double a nd Tr ip l e A i r
H ead P u m p s
Performance can be extended by stacking air pistons without
changing the hydraulic piston. Haskel multi-head pumps consume
less air than competitive single head pumps of the same area, as
only one head is pressurized on the return stroke; e.g., on a 1.5 hp
pump additional heads can raise performance to 2 hp.
Double air head pumps are identified by the last digit 2 in the
pump model number. Thus, a nominal 50:1 ratio pump with two
air heads is described as a 52. Similarly, a triple air head pump is
identified with a last digit 3. Thus, a 900 ratio pump with three air
heads is described as a 903.
O p er a t i o n
The pumps automatically reciprocate on a differential pistonprinciple. A large piston driven by relatively low pressure
drive acts directly upon a smaller hydraulic piston.
The nominal ratio between piston sizes is indicated in the
model coding and approximates to the maximum working
pressure. The actual ratio is about 15% above nominal so
that the pump continues to cycle when drive pressure equals
nominal ratio. Initially, the pump will cycle at maximum speed
acting as a transfer pump to pressurize downstream.
It will cycle at a slower rate as the fluid meets resistance
until it stalls at maximum output pressure. When a pressure
drop downstream occurs, it will recycle as necessary in
an effort to maintain maximum pressure. Stall pressure isachieved when the outlet pressure rises and offers more
resistance to the reciprocating differential piston assembly.
The piston assembly then stalls when the forces balance, e.g.
when drive pressure x drive piston area equals outlet (stall)
pressure x driven hydraulic plunger area. The pump design
is sensitive to very small pressure drops due to the low
frictional resistance of the large diameter drive piston and
hydraulic piston seals.
S ing le Dr iv e He a d P um p
0.65 sq in (4 sq cm)
Therefore, actual ratio = 40:1Nominal Ratio = 35:1
25.9 sq in (167 sq cm)
Doub le A i r He a d P um p
Area .65 sq in (4 sq cm)
Therefore, actual ratio = 79:1Nominal Ratio = 72:1*
Area 25.2 sq in (163 sq cm)
Area 25.9 sq in (167 sq cm)
Tr ip le A i r He a d P um p
Area .65 sq in (4 sq cm)
Therefore, actual ratio = 118:1Nominal Ratio = 103:1**
Nominal Ratio
* (2) Indicates Double Drive Piston** (3) Indicates Triple Drive Piston
Area 25.2 sq in (163 sq cm)
Area 25.2 sq in (163 sq cm)
Area 25.9 sq in (167 sq cm)
8/9/2019 Bomba Haskel..
4/24
Anatomy of a Pneumat ic Driven Pump
1. Drive Section
The piston, complete with “O” ring seal, operates in an epoxy lled,
fiberglass wound barrel, the diameter of which is constant throughout
a given series of pumps. Drive media forces the piston down on the
compression stroke and raises it on the suction stroke (M series have a
spring return). The piston is pre-lubricated during assembly and therefore
no air line lubricator is necessary.
2. Hydraulic Section/Check Valves This is directly linked to the drive piston by the hydraulic piston, the
bottom portion of which is in the hydraulic body. Outlet flow and pressure
are determined by the area of the hydraulic piston head, its nominal
ratio with the drive piston head, and drive pressure. On the down stroke,
liquid in the hydraulic section is forced under compression through the
outlet check valve. Fresh liquid is induced via the inlet check valve on
the return stroke. These check valves control the flow of liquid through
the hydraulic section. They are spring-loaded and have a very low
cracking pressure, allowing maximum opening on the induction stroke.
The pressure of hydraulic fluid on the down stroke closes the inlet check
valve and acts against the spring to open the outlet check valve.
3. Drive Cycling Valve This is a pilot-operated, unbalanced, lightweight spool, which directs
drive pressure, first to the top of the drive piston, and then to the
underside to reciprocate the piston (cycle). It actuates via pilot valves at
the top and the bottom of the stroke, which causes the unbalanced spool
to shift and reciprocate the piston.
4. Hydraulic Seal/Check Valves
This is one of the few wear parts. Its function is to allow the hydraulic
piston to reciprocate without passing fluid into the drive section. The liquid,
its pressure and its temperature determine seal specication. A distance
piece can be incorporated between drive and hydraulic sections for
complete contamination-free operation on most Haskel pumps.
www.haskel.com
Drive
Section
Hydraulic
Check
Valves
Drive
Cycling
Valve
HydraulicSeal/Check
Valve
8/9/2019 Bomba Haskel..
5/24
8/9/2019 Bomba Haskel..
6/24www.haskel.com
1 2 5 p s i / 8 . 6
b a r
1 5 0 p
s i / 1 0 . 5
b a r
1 0 0 p s i / 7 b a r
1 5 0 p s i / 1 0 . 5
b a r
1 0 0 p s i / 7 b a r
1
2 5 p s i / 8 . 6
b a r
M a x D r i v e
S i n g l e
T r i p l e
D o u b l e
S i n g l e
S i n g l e
S i n g l e
D r i v e H e a d
1 0 h p
8 h p
6 h p
3 h p
2 . 2
2 h p
2 h
p
1 . 5
h p
0 . 7
5 h p
0 . 3
3 h p
H P Pump Model Code
NominalRatio
ActualRatio
Maimimum Rated Output PressureDisplacement/Cycle Maximum
Continuous Intermittent
psi bar psi bar cu in ml cu in/min
M, MDSTV -5 5.6 625 43 625 43 0.83 13.6 506
M, MS -7 7.8 900 62 900 62 0.60 9.8 366
-12 14 1500 103 1500 103 0.36 5.9 234
M, MS, 29723
-21 25 2600 179 2600 179 0.20 3.3 130
-36 41 4500 310 4500 310 0.12 2.0 78
-71 82 8800 607 8800 607 0.060 1.0 39
-110 126 13500 931 13500 931 0.039 0.6 25M, MS -188 217 15000 1034 15000 1034 0.023 0.4 18
MS -220 237 20000 1380 25000 1723 0.021 0.344 14
4B
-14 16 1500 103 1500 103 0.90 14.7 428
-21 24 2300 159 2300 159 0.60 9.8 285
-25 29 2700 186 2700 186 0.50 8.2 238
-30 34 3200 221 3200 221 0.43 7.0 204
-37 42 3800 262 3800 262 0.35 5.7 166
-55 63 6000 414 6000 414 0.22 3.6 105
-75 86 7800 538 7800 538 0.17 2.8 81
-100 114 10600 731 10600 731 0.13 2.0 62
-150 171 15000 1034 15000 1034 0.088 1.44 42
DSTV -1.5 1.6 120 8 160 11 31.90 513 5104
ATV, DTV -4 80 690 48 1200 83 20.00 328 3200
AW, ASF, DF, DSF, DSTV
-B10 11.5 1600 110 1600 110 4.05 66.4 1215
-B15 17 2400 165 2400 165 2.70 44.3 810
-25 29 4000 276 4000 276 1.62 26.6 486
-35 40 5700 393 5700 393 1.16 19.0 348
-60 69 9800 676 9800 676 0.67 11.0 201
-100 115 15000 1034 16500 1138 0.41 6.7 123
-150 173 15000 1034 20000 1380 0.27 4.5 81
HF, HSF, DHF, DSHF
-151 173 25000 1724 25000 1724 0.27 4.5 81
-225 260 30000 2069 37000 2551 0.18 3.0 41
-300 345 30000 2069 50000 3448 0.14 2.3 32
HF -450 533 25000 1724 45000 3403 0.091 1.5 20
AW, ASF, DF, DSF, DSTV
-B22 23 3200 221 3200 221 4.05 66.4 1215
-B32 34 4800 331 4800 331 2.70 44.3 810
-52 57 5000 345 8000 552 1.62 26.6 486
-72 80 11000 758 11000 758 1.16 19.0 348
-122 138 15000 1034 19000 1310 0.67 11.0 201
HF, HSF, DHF, DSHF-202 230 30000 2069 33000 2275 0.41 6.7 92
-302 346 30000 2069 50000 3448 0.27 4.5 61
DXHF, DSXHF -452 520 30000 2069 70000 4827 0.18 3.0 41
-602 690 30000 2069 75000 5171 0.14 2.3 32
DXHF, DSXHF -683 780 30000 2069 70000 4827 0.18 3.0 25
-903 1038 30000 2069 75000 5171 0.14 2.3 20
DSXHW -1373 1575 30000 2069 100000 6895 0.086 1.4 12
AFD, DFD, ASFD, DSFD -B60 69 6500 448 6500 448 1.34 2.2 369
ASFD
-10 11.5 1600 110 1600 110 8.10 133 1823
-15 17 2400 165 2400 165 5.40 89 1215
-25 29 4000 276 4000 276 3.24 53.2 729
-35 40 5700 393 5700 393 2.32 38.0 522
-60 69 9800 676 9800 676 1.34 22.0 302
-100 115 15000 1034 16500 1138 0.82 13.4 185-150 173 15000 1034 20000 1380 0.54 9.0 122
-202 230 30000 2069 33000 2275 0.82 13.4 144
GWD, GSFD, DGFD, DGSFD, DGSTVD -12 14.8 1850 128 4000 276 15.9 260 5009
GW, DGF, GSF, DGSF, DGSTV
-35 40.3 4375 302 4375 302 6.0 98 1890
-60 69 7500 517 7500 517 3.5 57 1103
-100 115 8000 552 10000 690 2.1 34 662
8SFD, 8DSFD, 8DSTVD -25 27.5 3575 246 4000 276 14.0 229 2660
8SFD-40 43.5 6000 414 6000 414 8.90 145 1691
-65 73 10000 690 10000 680 5.40 88 1026
8DSFD -100 112 10000 690 10000 680 3.52 57.5 669
8HSFD -225 253 22500 1530 22500 1530 1.56 25.5 296
D14STD, D14SFD -125 138 16000 1103 16000 1103 8.80 144 704
-315 347 36000 2482 36000 2482 3.50 57.4 280
P er f o r m an ce an d S p ec i f i ca t i o n O ver v i ew
8/9/2019 Bomba Haskel..
7/24
Typical Performance Based on 100 psi (7 bar) Pressure and Drive Flow Data on Page 5
Outlet Pressure Outlet Flow Outlet Pressure Outlet Flow
psi bar cu in/min l/min psi bar cu in/min l/min
225 15.5 500 8.20 415 29 249 4.09
300 21 350 5.70 600 41 160 2.60
700 48 200 3.28 1125 78 100 1.64
1500 103 90 1.48 2000 138 48.9 0.80
1700 117 70 1.15 3100 214 39.6 0.65
3000 207 39 0.64 6000 414 19 0.31
7500 517 20 0.33 8500 586 17 0.285000 345 18 0.30 10000 690 14 0.23
7500 517 14 0.23 15000 1034 12 0.20
700 48 400 6.55 1450 100 61 1
1000 69 270 4.42 2000 138 120 2
1250 86 230 3.77 2500 172 61 1
1500 1034 200 3.28 3000 207 62 1
1750 121 170 2.78 3500 241 82 1.33
2000 138 110 1.8 5000 345 66 1.08
2500 172 87 1.42 7500 517 37 0.6
5000 345 57 0.93 10000 690 26 0.43
7500 517 37 0.6 15000 1034 7 0.11
50 3 5000 81.9 150 10.3 1000 16.4
100 7 1953 32 400 28 750 12.3
400 28 1000 16.4 990 68 500 8.19
750 52 598 9.8 1600 110 200 3.28
1000 69 403 6.6 2500 172 195 3.2
2000 138 350 4.1 3600 248 98 1.6
3000 207 152 2.5 6200 427 50 0.82
4000 276 100 1.64 10000 690 24.4 0.4
7000 483 59.7 0.98 15000 1034 29.9 0.49
7000 483 59.7 0.98 15000 1034 29.9 0.49
7500 517 39.6 0.65 24000 1655 9.8 0.16
5000 1034 29.9 0.49 27000 1862 20.1 0.33
36000 2483 14.6 0.24 45000 3103 9.2 0.15
400 28 799 13.1 2100 145 200 3.28
700 48 500 8.2 3000 207 152 2.5
1900 131 299 4.9 5000 345 97.6 1.6
2000 138 226 3.7 7500 517 50 0.82
4000 276 122 2 12000 828 40.2 0.667000 483 91.5 1.5 20000 1379 20.1 0.33
0000 690 45.2 0.74 30000 2069 15.2 0.25
0000 690 34.8 0.57 40000 2759 15.2 0.25
5000 1034 24.4 0.4 50000 3448 12.2 0.2
5000 1034 19.5 0.32 60000 4138 4.9 0.08
5000 1034 15.9 0.26 70000 4828 5.5 0.09
6000 1103 9.2 0.15 90000 6207 3.1 0.05
1000 69 348 5.7 5500 379 152 2.5
500 34 1520 24.9 1000 69 380 6.22
750 52 1030 16.88 1500 103 260 4.26
1000 69 662 10.85 2500 172 162 2.66
1500 1034 465 7.62 3500 248 100 1.64
3000 138 248 4.07 6000 414 56 0.92
5000 345 151 2.48 10000 690 41 0.677500 517 103 2 15000 1034 27 0.44
0000 690 63 1.03 20000 1379 47 0.77
200 14 5004 82 1200 83 1454 24
1000 69 1770 29 3500 241 600 9.8
2000 138 976 16 5500 379 397 6.5
2000 138 573 9.4 10000 690 195 3.2
1000 69 2400 39.3 2500 172 280 4.6
2000 138 1420 23.2 4000 276 200 3.27
3000 207 880 14.4 6000 414 310 5.08
5000 345 555 9.1 10000 690 163 2.67
0000 690 270 4.4 20000 1379 144 2.36
8000 552 488 8.0 12000 828 195 3.2
5000 1034 238 3.9 30000 2069 79.3 1.3
Pump Series Maximum Cycles per Minute
0.3 hp 325 cpm
0.75 hp 225 cpm
1.5, 2.0 and 2.2 hp(Single and Double Drive Piston)
80 cpm
2.0 hp (Triple Drive Piston) 60 cpm
3.0 hp 80 cpm
6.0 hp 60 cpm
8.0 hp 50 cpm
10.0 hp 40 cpm
Guide l ines fo r Cont inuous Duty
App l ica t ions fo r Max imiz ing
S ea l L i f e P er f o r m an ce
www.haskel.com
8/9/2019 Bomba Haskel..
8/24www.haskel.com
Key Features
• Choice of 5 models, 9 ratios,
27 possible combinations• Flows to 2 gpm (7.5 l/min)
• Choice of wetted materials
• Single air head
• Drive pressure 25 to
125 psi (1.8 to 9 bar)
• Pressures to 25000 psi
(1724 bar)• All Hydraulic uids, water
(plain or DI), solvents, mild
chemicals, liquefied gases
. 33 hp ( .25 kW) M Ser ies Pump Models
ModelNominalRatio Maximum Working Pressure
Displacementper Cycle
M,MDSTV
-5 625 psi (43 bar) .83 cu in (13.6 ml)
M, MS(3) -7
-12
900 psi (62 bar)
1500 psi (103 bar)
.6 cu in (9.8 ml)
.36 cu in (5.9 ml)
M, MS(3),29723(3)**
-21
-36
-71
-110
-188
2600 psi (179 bar)
4500 psi (310 bar)
8800 psi (607 bar)
13500 psi (931 bar)
15000 psi (1034 bar)
.2 cu in (3.3 ml)
.12 cu in (2.0 ml)
.06 cu in (1.0 ml)
.039 cu in (0.6 ml)
.023 cu in (.4 ml)
MS -220 25000 psi (1723 bar) .021 cu in (.34 ml)
** Not available in 188 ratio
(3) Maximum intermittent pressure for stainless steel in the MS and 29723 is 10000 psig (690 bar.)
Number Description
-HP
26082 26220-2
26220-3
Hand pump attachment (with handle). Provides manual operation of pump forprecision pressure control or use without air power.
Handle only.With handle.
Without handle.Kits for converting existing units.
-V Manual release with relief valve. For M and MS pumps only. Provides high pressureneedle valve with internal adjustable safety relief downstream of pump outletchecks. Tank return is 1 ⁄ 8” NPT in pump body.
26063-3 Dead Man valve. ¼” NPT port.
26064-3 Combination air regulator/lter with gauge. ¼” NPT port.
26065-3 Speed control valve. ¼” NPT port.
26065-3plus26064-3
-C air controls installed on pump. ¼” NPT port.
28320 Manifold mount inlet port. Provides O-ring boss in aluminum block to enable mountingon side of tank below oil level. Modication applies to M-21 through M-188 only.
28590 Palm or foot start/stop button drive. Spring loaded shut.
28700-1 Air OP release valve.
28926 Remote start/stop control. Provides 1 ⁄ 8” NPT bleed signal port for single lineremote control.
29002 Viton air drive.
29697 Single stroke from remote air pulse. Useful for metering applications. One stroke perair pulse signal; eliminates automatic cycling. 1 ⁄ 8” NPT signal port.
51331 EPR seals for liquid section for 29723-XX ratio pumps.
51788 Piped exhaust – standard. Provides connection ports for drive and pilot exhausts.Enables under tank top mounting and/or natural gas drive.
51794 Piped exhaust – sour gas. With hand pump (HP).
51794-2 Piped exhaust – sour gas. Without hand pump (HP).
51804 Mufer (for use with piped exhaust modications below). ¼” NPT male port.
Number Description
51809 Normally open air operated release with relief valve. Provides highest release owcapacity. Will hold full pump psi piloted from drive air. Vents are not threaded. Ref.drawing 56643 for tank top mounting parts.
51809-1 Normally closed air operated release with relief valve. Used to hold hydraulic jacks.Will release up to 11000 psi (using 100 psi air). Vents are not threaded. Ref. drawing56643 for tank top mounting parts. Not available in 188:1 ratio.
51810 Safety relief valve. Relief is upstream of outlet check. Vent hole 1/16 NPT M or MSseries -21 through 188.
51811 External air pilot. Provides 1 ⁄ 8” NPT port for external air to pilot for remote start/stop.
52340 Solid air cap.
52950 Electric stroke counter provision. Micro switch (BZE6-2RQ) mounted on upper cap trips with each cycle.
53175 Level II cleaning.
53304 High pressure outlet port. Fits ¼” O.D. high pressure threaded and coned tube.
53784 Piped exhaust (drive only). For eld conversion of any .33 HP pump. Provides ¼” NPTexhaust port.
53935 Low temperature drive. Enables operation down to 5°F. Some sacrice of seal life atnormal temperature. M or MS series.
54179 Stroke adjuster (includes 29697 above). Useful for metering applications. Knurledknob with vertical scale on pump cap.
57905 No return spring. Provides improved ll on suction stroke pumping liqueed gasesby utilizing the inlet pressure. Only available on M and MS series.
59888 Cycle timer installed.
80103 Noise reduction kit tted.
80348 SAE outlet for M-pumps, 3 ⁄ 8” SAE, 6500 psi (448 bar) max.
81499 EPR Seals for M and MS series for Liquid Section.
82367 SS trim for 1 ⁄ 3 hp drive
82500 ATEX Modication (Available on MS & 29723 but not M series).
85630 Conversion kit, new style exhaust mufer.
86337 Extended life air drive.
Optional Modifications
For service codes, see page 17.
For weights and dimensions, see page 18.
8/9/2019 Bomba Haskel..
9/24
Key Features
• One model available
in 9 ratios• Output pressures to
15000 psi (1034 bar)
• Flows to 1.5 gpm (5.7 l/min)
• Choice of wetted materials
• Single air head• Air drive pressure 3 psi to
100 psi (0.2 to 7 bar)
ModelNominalRatio Maximum Working Pressure
Displacementper Cycle
4B -14
-21
-25
-30
-37
-55
-75
-100
-150
1500 psi (103 bar)
2300 psi (159 bar)
2700 psi (186 bar)
3200 psi (221 bar)
3800 psi (262 bar)
6000 psi (414 bar)
7800 psi (538 bar)
10600 psi (731 bar)
15000 psi (1034 bar)
.9 cu in (14.8 ml)
.6 cu in (9.8 ml)
.5 cu in (8.2 ml)
.43 cu in (7.1 ml)
.35 cu in (5.7 ml)
.22 cu in (3.6 mil)
.17 cu in (2.8 ml)
.13 cu in (2.1 ml)
.088 cu in (1.4 ml)
Number Description
-C Air drive controls.
56564 Extreme cycling service. Not recommended for long stall periods.
56594 External air pilot port
1
⁄ 8
” NPT. Allows remote start/stop of pump.57639 Low drive air pressure. Allows user to regulate drive air to as low as 3 psi (0.21 bar).
57960 Single acting drive. Used for pumping liqueed gases under pressure.
58475 1 ⁄ 8” NPT port on drive for recycle valve connection.
59354 Noise reduction kit tted.
Number Description
59888 Cycle timer installed.
80637 SAE outlet tting for ratio 37 to 100, 1 ⁄ 4” SAE, 6500 psi (448 bar) max.
82104 Viton air drive.82500 ATEX modication.
86337 Extended life air drive.
Optional Modifications
www.haskel.com
. 75 h p ( . 56 kW) P u m p M o d e l s
For service codes, see page 17.
For weights and dimensions, see page 19.
8/9/2019 Bomba Haskel..
10/24www.haskel.com
Key Features
• Choice of 11 models,
13 ratios, 48 possible
combinations• Output pressures to
50000 psi (3448 bar)
• Flows to 22 gpm (83.0 l/min)
• Choice of wetted materials
• Single air head
• Air drive pressure 2.9 to 150
psi (0.2 to 10 bar)
ModelNominalRatio Maximum Working Pressure
Displacementper Cycle
DSTV(1) -1.5 160 psi (11 bar) 31.9 cu in (513.0 ml)
ATV,
DTV(1)-4 1200 psi (83 bar) 20.0 cu in (328.0 ml)
AW, ASF,DF, DSF,DSTV
-B10
-B15
-25
-35
-60
1600 psi (110 bar)
2400 psi (165 bar)
4000 psi (276 bar)
5700 psi (393 bar)
9800 psi (676 bar)
4 cu in (66.4 ml)
2.7 cu in (44.3 ml)
1.6 cu in (26.6 ml)
1.2 cu in (19 ml)
.7 cu in (11 ml)
AW, ASF,DF, DSF,DSTV
-100
-150
16500 psi (1138 bar)
20000 psi (1375 bar)
.4 cu in (6.7 ml)
.28 cu in (4.5 ml)
HF, HSF,DSHF
-151
-225
-300
25000 psi (1724 bar)
37000 psi (2551 bar)
50000 psi (3448 bar)
.28 cu in (4.5 ml)
.18 cu in (3.0 ml)
.14 cu in (2.3 ml)
HF -450 45000 psi (3403 bar) .09 cu in (1.5 ml)
(1) These series are “Lift” pumps and maximum outletpressure is (air drive x pump ratio) + inlet pressure
Number Description
-C Air controls (lter, regulator, gauge, shut-off). ½” NPT.
-CP Air controls with precision regulator. ½” NPT.
-CO Air controls with recycle button. ½” NPT.-CPO Air controls with precision regulator and recycle button. ½” NPT.
-B Bottom Inlet (designate “B” before ratio dash number, “BR” on -B10, -B15, -B22and -B32) 1.5 hp and 2 hp pumps (not applicable to high output, chemical, 2.2 hp,or AWD series pumps).
-W Additional upper foot bracket.
16821 Low air pressure control feature. For operating at air pressures as low as 3 to 4psi (0.2 to 0.3 bar). Includes 28881 modication.
16831 Low temperature modication. For special sealing in air drive for operating temperatures from as low as -20°F up to normal +120°F.
16834 Exhaust adapter. With back pressure balance piston.
17860 Electrical stroke counter provision. Includes BZE6-2RQ microswitch.
25721 Mechanical stroke counter, installed (6 digit).
27964 Interconnecting inlet-outlet tubing. ½” female for 4:1 ratio series pumps(ATV-4 or DTV-4).
28000 Threaded vent (or purge) ports on standard distance piece. Except 1.5:1 ratio.
28003 Test port. Provides access port in pump’s body between inlet and outlet checkvalves for 1.5 hp and 2 hp pumps. -10 ratio or higher, single acting.
28881 Air pilot modication. 1 ⁄ 8” NPT. Allows remote start/stop of pump.
29376 Three-way cycling spool. For 1.5 hp and 2 hp single acting pumps, for use with CO2
29702 Single stroke modication.
Number Description
29806 Double distance piece. For 1.5 hp and 2 hp pumps only, except 1.5:1 ratio.
51050 Extreme service cycling modication. Not recommended for long stall periods.
51056 Exhaust/pilot vent combination.
51331 EPR (Ethylene propylene) static seals in wetted section. Applies to distancepiece pumps only.
51345 Sour gas drive provision to N.A.C.E. specications. 1.5 hp to 2.2 hp distancepiece pumps only, single air head and double air head.
52788 Viton seals air drive.
53925 Severe Arctic low temperature service. -25, -35, -60, -100, -150, -151, -225, -300,-450 ratios.
54885 Rotate pump body 90° from standard.
54935 SS trim for 5/3 air drive.
55305 Tube ports. 5 ⁄ 8” SAE inlet and outlet. For 1.5 hp to 2 hp pumps. 15 pump minimum.
55516 Polyurethane (“W”) seal. For F or TV series pumps, except high output models.
55630 Stainless steel (AISI-316) distance piece. For 1.5 hp to 2 hp pumps.
59353 Noise reduction kit tted. Not available on AFD, DFD, ASFD or DSFD.
82460 HNBR seals in air drive section.
82500 ATEX modication (not available on AW or DSXHW pumps).
82958 9 ⁄ 16 High pressure outlet converts medium ratio 10-122 outlet 1 ⁄ 2 port to highpressure port.
86337 Extended life air drive.
Optional Modifications
1 . 5 h p ( 1 . 12 kW) P u m p M o d e l s
For service codes, see page 17.
For weights and dimensions, see page 20.
8/9/2019 Bomba Haskel..
11/24
1 .5 hp (1 . 12 kW) H i gh Output
F l o w P u m p s
Available in a choice of 3 models, these high output, low ratio
pumps are capable of pressures to 1200 psi (82 bar) and ow
rates of up to 22 gpm (83 l/min). These are “lift” pumps whereby the outlet pressure equals the air drive x the pump ratio plus the
inlet pressure.
Model DSTV-1.5 has a maximum air drive of 150 psi (10 bar) and
is capable of pressures up to 160 psi (11 bar). The model ATV
and DTV-4 work on a maximum air drive of 150 psi (10 bar) and
have a maximum pressure rating of 1200 psi (83 bar). A noise
reduction modification is available for applications where noise
level is an issue.
D i s t an ce P i ece ( S ep ar a t i o n )
Pumps with prex “D” in the model number have aluminum
distance piece between the air drive and pump section (exceptDSTV-1.5). Vent holes can be threaded ½” NPT female at extra
cost. Specify modication number 28000. Horizontal mounting is
recommended for non-exchange of contaminants.
D i men s i on a l D at a Mo un t i ng Br a ck e ts
O p t i o n a l P u m p I n l e t s f o r T a n k M o u n t i n g
To specify ratios-10, -15, -22 or -32,add “BR” between the model numberand the ratio, e.g.AW-BR10.
Inlet externally threaded 1 ¼”NPT male
Internally threaded1” NPT female
Drive inlet and exhaust are ½” NPT female. Drive inlet also includes a ½” NPT male x ½” NPSM female(straight pipe thread) swivel adapter (connecting male nipple should include 30° inside bevel for prope
To specify ratios-25 through -903add “B” betwee the model numband the ratio, e.gAW-B25.
Inlet on the bottand externally threaded1” NPT male
Internally thread½” NPT female
www.haskel.com
M o u n t i n g B r acke t s
All series mounting brackets have 7/16” holes (slots) for 3/8”
bolts. Upper mounting brackets are not furnished as standard
on single air head non-distance piece units.
8/9/2019 Bomba Haskel..
12/24www.haskel.com
Key Features
• Choice of 16 models,
13 ratios, 46 possible
combinations• Output pressures to
100000 psi (7000 bar)
• Flows to 5 gpm (15 l/min)
• Choice of wetted materials
• Double and triple air heads
• Air drive pressure 2.9 to
145 psi (0.2 to 10 bar)
2
h p
2 . 2
h p
ModelNominalRatio Maximum Working Pressure
Displacementper Cycle
AW, ASF,DF, DSF,DSTV
-B22
-B32
-52
-72
-122
3200 psi (221 bar)
4800 psi (331 bar)
8000 psi (552 bar)
11000 psi (758 bar)
19000 psi (1310 bar)
4 cu in (66.4 ml)
2.7 cu in (44.3 ml)
1.6 cu in (26.6 ml)
1.2 cu in (19 ml)
.7 cu in (11 ml)
HF, HSF,DHF, DSHF
-202
-302
33000 psi (2275 bar)
50000 psi (3448 bar)
.4 cu in (6.7 ml)
.28 cu in (4.5 ml)
DXHF,DSXHF
-452
-602
70000 psi (4827 bar)
75000 psi (5171 bar)
.18 cu in (3.0 ml)
.14 cu in (2.3 ml)
DXHF,DSXHF
-683
-903
70000 psi (4827 bar)
75000 psi (5171 bar)
.18 cu in (3.0 ml)
.14 cu in (2.3 ml)
DSXHW -1373 100000 psi (6895 bar) .09 cu in (1.4 ml)
AFD, DSFD,DFD, ASFD
-B60 6500 psi (448 bar) 1.3 cu in (22 ml)
Key Features
• One model available
in 8 ratios
• Output pressures to
33000 psi (2275 bar)
• Flow rates to 8 gpm (30 l/min)
• Single air head
• Air drive pressure 3 to 150 psi
(0.2 to 10.0 bar)
ModelNominalRatio Maximum Working Pressure*
Displacementper Cycle
ASFD 10
15
25
35
60
100
150
202
1600 psi (110 bar)
2400 psi (165 bar)
4000 psi (276 bar)
5700 psi (393 bar)
9800 psi (676 bar)
16500 psi (1138 bar)
20000 psi (1379 bar)
33000 psi (2275 bar)
8.1 cu in (132.8 ml)
5.4 cu in (88.6 ml)
3.3 cu in (53.2 ml)
2.3 cu in (38 ml)
1.3 cu in (22 ml)
.8 cu in (13.4 ml)
.6 cu in (9 ml)
.8 cu in (13.4 ml)
* Continuous/Intermittent
2 & 2 . 2 h p ( 1 . 49 & 1 . 64 kW) P u m p M o d e l s
3 h p ( 2 . 24 kW) P u m p M o d e l s
For service codes, see page 17.
For weights and dimensions, see page 20.
For service codes, see page 17.
For weights and dimensions, see page 21.
8/9/2019 Bomba Haskel..
13/24
Number Description
-C Air controls (lter, regulator, gauge, shut-off. ½” NPT.
-CP Air controls with precision regulator. ½” NPT.
-CO Air controls with recycle button. ½” NPT.
-CPO Air controls with precision regulator and recycle button. ½” NPT.
-B Bottom Inlet (designate “B” before ratio dash number, “BR” on -B10, -B15, -B22and -B32) 1.5 hp and 2 hp pumps (not applicable to high output, chemical, 2.2 hp,or AWD series pumps)
16821 Low air pressure control feature. For operating at air pressures as low as 3 to 4psi (0.2 to 0.3 bar).
16831 Low temperature modication. For special sealing in air drive for operating temperatures from as low as -20°F up to normal +120°F.
16834 Exhaust adapter. With back pressure balance piston.
17860 Electrical stroke counter provision. Includes BZE6-2RQ microswitch.
25721 Mechanical stroke counter. Installed (6 digit).
27964 Interconnecting inlet-outlet tubing. ½” female for 4:1 ratio series pumps (ATV-4or DTV-4).
28000 Threaded vent (or purge) ports on standard distance piece. Except 1.5:1 ratioand 3 hp pump.
28003 Test port. Provides access port in pump’s body between inlet and outlet checkvalves for 1.5 hp and 2 hp pumps, -10 ratio or higher, single acting.
28881 Air pilot modication. 1 ⁄ 8” NPT – Allows remote start/stop of pump.
29376 Three-way cycling spool. For 1.5 hp and 2 hp single acting pumps.
29702 Single stroke modication. Except 3 hp pump.
29806 Double distance piece. For 1.5 hp and 2 hp pumps only, except 1.5:1 ratio.
Number Description
51050 Extreme service cycling modication. Not recommended for long stall periods.
51056 Exhaust/pilot vent combiner.
51331 EPR (Ethylene propylene) static seals in wetted section. Applies to distancepiece pumps only.
51345 Sour gas drive provision to N.A.C.E. specications. 1.5 hp to 2.2 hp distancepiece pumps only, single air head and double air head.
52788 Viton seals. Air drive only – 1.5 hp to 2.2 hp pumps only.
53925 Severe Arctic low temperature service. -25, -35, -60, -100, -150, -151, -225, -300,-450 ratios except 3 hp pump.
54885 Rotate pump body 90° from standard. Except 3 hp pump.
54935 SS trim for 5/3 air drive.
55191 Mounting ring kit for AWD series.
55192 3/4 NPT inlet port installed on AWD series (in place of threaded port).
55193 Extra foot bracket installed.
55305 Tube ports. 5 ⁄ 8” SAE inlet and outlet – for 1.5 hp to 2 hp pumps, 15 pump minimum.
55465 Ceramic Plunger -60 Ratio.
55516 Polyurethane “W” seal in “F” series pumps-except high output models.
55630 Stainless steel (SS-316) distance piece – for 1.5 thru 2 hp pumps.
59353 Noise reduction kit tted. Not available on AFD, DFD, ASFD or DSFD.
59888 Cycle timer installed.
82460 HNBR Seals in air drive section.
82500 ATEX modication (not available on AW or DSXHW pumps).
86337 Extended life air drive.
Optional Modifications (for 2 hp, 2.2 hp and 3 hp pump models)
www.haskel.com
8/9/2019 Bomba Haskel..
14/24www.haskel.com
Key Features
• Choice of 6 models, 5 ratios,
9 possible combinations
• Pressures to 22500 psi
(1530 bar)
• Flow rates to 11.5 gpm
(44 l/min)
• All hydraulic uids, water
(plain or DI), solvents,
liquefied gases
• Choice of wetted materials
• Single air head – double acting
• Air drive pressure 15 to 125
psi (1 to 9 bar)
ModelNominalRatio Maximum Working Pressure
Displacementper Cycle
8SFD,8DFD,8DSFD,8DSTVD8FD
-25(1) 4000 psi (276 bar) 14 cu in (229 ml)
8SFD8DSFD
-40
-65
-100(1)
6000 psi (408 bar)
10000 psi (690 bar)
10000 psi (690 bar)
9 cu in (145.3 ml)
5.4 cu in (88.2 ml)
3.5 cu in (57.5 ml)
8HSFD -225(1) 22500 psi (1530 bar) 1.6 cu in (25.5 ml)
(1) Double Acting “Lift” Pumps
Key Features
• Choice of 10 models, 4 ratios,
20 possible combinations• Output pressures to
10000 psi (690 bar)
• Flow rates to 21 gpm (80 l/min)
• Choice of wetted materials
• Single air head –
double acting• Air drive pressure 15 to
125 psi (1 to 9 bar)
• All hydraulic uids, water
(plain or DI), solvents
ModelNominalRatio Maximum Working Pressure
Displacementper Cycle
GWD,GSFD,DGFD(1),DGSFD(1),DGSTVD(1)
-12 4000 psi (276 bar) 15.9 cu in (260 ml)
GW, GSF,DGF,DGSF,DGSTV
-35
-60
-100
4375 psi (302 bar)
7500 psi (517 bar)
10000 psi (690 bar)
6.0 cu in (98 ml)
3.5 cu in (57 ml)
2.1 cu in (34.5 ml)
(1) Double Acting “Lift” Pumps
6 h p ( 4 . 47 kW) P u m p M o d e l s
8 h p ( 5 . 97 kW) P u m p M o d e l s
Incorporating 10 models, this heavy duty range of double acting
pumps provide pressures up to 10000 psi (690 bar) and ow ratesup to 4 gpm (15 l/min).
Designed to operate with air drive pressures between 40 and 125
psi (2.8 and 9 bar). For drive pressures 3 to 40 psi (.2 to 2.8 bar),
order 51875-1 mod.
For service codes, see page 17.
For weights and dimensions, see page 22.
For service codes, see page 17.
For weights and dimensions, see page 23.
8/9/2019 Bomba Haskel..
15/24www.haskel.com
Key Features
• Choice of 4 models, 4 ratios,
4 possible combinations
• Pressures to 36000 psi
(2500 bar)
• Flow rates to 3 gpm (11 l/min)
• All hydraulic uids, water
(plain or DI), solvents,
liquefied gases
• Choice of wetted materials
ModelNominalRatio Maximum Working Pressure
Displacementper Cycle
D14STD 125(1)
315(1)16000 psi (1103 bar)36000 psi (2482 bar)
8.8 cu in (144.2 ml)3.5 cu in (57.4 ml)
D14SFD 125(1)315(1)
16000 psi (1103 bar)36000 psi (2482 bar)
8.8 cu in (144.2 ml)3.5 cu in (57.4 ml)
(1) Double Acting “Lift” Pumps
Incorporating two basic models, this heavy duty range of double
acting pumps provide pressures up to 36000 psi (2482 bar) and
output ow rate up to 3 gpm (11 l/min).
Operating from a maximum air drive pressure of 125 psi (9 bar),
these pumps are designed for medium to high pressure service
with minimum maintenance.
These large, slow speed pumps approach a seal life as high as 5
times that of many smaller pumps and this advantage becomes
ever greater in heavy duty service involving water, or other liquids
with negligible lubricity.
Number Description
C Air controls.17860 Electrical stroke counter provision (includes BZE6-2RQ micro switch).
25721 Mechanical stroke counter installed (6 digit).
29077 Interconnecting tubing – 6 hp and 8 hp pumps, double ended.
29077-1 Interconnecting tubing – 6 hp and 8 hp pumps, double ended low ratio pumps.
29078 Same as 29077, 29077-1 double ended w/distance piece.
29078-1 Same as 29077, 29077-1 double ended w/distance piece low ratio pumps.
29079 Interconnecting tubing – 10 hp pumps.
29125 External pilot modication – for 6 hp thru 10 hp pumps.
51875-1 Low air pressure control – for 6 hp thru 10 hp pumps.
54030 Sour gas air drive provision to NACE spec. 6 hp distance piece pumps only.
Number Description
54312 Extreme service cycling modication – for 6 hp thru 10 hp pumps.54936 Exhaust/pilot vent combiner.
55330 Interconnecting tubing 8DSFD-100 low pressure inlet.
55330-1 Interconnecting tubing 8DSFD-100 high pressure inlet.
55366 Interconnecting tubing 8DSFD-225.
57002 Viton seals – air drive only – 6 hp.
57944 Viton seals – air drive only – 8 hp.
59888 Cycle timer installed.
82500 ATEX modication available for 6 hp only, not available on 8 hp or 14 hp drive, nor onGW, GSF, DGSF, GSFD, or DGSFD models.
86337 Extended life air drive.
Optional Modifications (for 6 hp, 8 hp and 10 hp pump)
www.haskel.com
10 h p ( 7 . 46 kW) P u m p M o d e l s
For service codes, see page 17.
For weights and dimensions, see page 23.
8/9/2019 Bomba Haskel..
16/24
• Air pilot switches
• Air pilot valves
• Regulating relief valves
• Directional control and release valves• Hydraulic accumulators, gas receivers
and storage cylinders
• High pressure valves, ttings and
tubing
• Plenum chambers
• Port adapters
• Pressure regulators
• Gauge snubbers
• Filters
• Stainless steel check valves
• Intensiers with integral checks for
cycling
• Capillary type gauge snubbers
Please ask for your copy of our latestaccessories brochure.
S e l ec t i n g Y o u r A ccesso r i es
Haskel can either provide accessories separately or supply them fitted to form a complete
package suited to your application. Additionally, Haskel can t customer nominated
accessories. Our accessories catalog is available and our technical support team is always
ready to advise you on the most suitable choice of accessories for your application.
P o w er S ys t em S p ec i a l i s t s
World safety standards and quality demands are rising.
Component manufacturers are required to provide test
certification and product quality assurance which can only be
determined using the types of systems which Haskel can provide.
Typically, we have built systems for production and field testing
the proof, leak, and burst aspects of hoses, cylinders, and valves.
These systems can be portable, mobile, or static test rigs. We also
offer a range of standard pressure packs used for power jacking,
clamping, and other applications where reliable power is needed.
Qual i t y and
A f t e r - S a l e S er v i ce
Haskel meets the requirements of international
quality assurance ISO 9001. Build quality is
matched by an innovative design and problem
solving ability which stems from years of years of experience.
Our representatives around the world are carefully chosen and
trained to help you arrive at a correct product choice, and to offer
a maintenance and parts service that is second to none.
www.haskel.com
8/9/2019 Bomba Haskel..
17/24www.haskel.com
L iqu ids Compat ib le w i th
H aske l P u m p s
To assist in easier pump selection, we have classified various
popular liquids in groups and assigned to each group a service
code. These service code numbers are featured in the chart to
the right and are designated for each pump series. Seals and
other wetted materials can be supplied to suit your preferred
liquid. For advice, please contact our technical services
personnel at 818-843-4000.
S er v i ces
Service Codes
1 Petroleum-based oils, kerosene, water with 5% soluble oil.
2 Plain water, diesel fuel.
3 Most phosphate ester-based re-resistant hydraulic uids,e.g. Pydraul, Lindol, Cellulube, Fyrquel, and Houghtosafe
1120 and petroleum-based solvents compatible with
UHMWPE (Ultra-high Molecular Weight Polyethylene)
dynamic seals and Viton static seals.
4 Petroleum-based solvents, e.g. boron fuels, aromatic
hydrocarbons (benzene, toluene, xylene, hylene, etc.);chlorinated solvents (trichlorethylene, carbon tetrachloride,
chlorobenzine, etc.); mercaptans, Dowtherm A, uoronated
solvents (uorobenzene, uorochlorethylene, etc.);
Dowtherm E, plus all of Group 3 and some mildly corrosive
acids compatible with wetted materials. See note 5A
for service with methyl-ethyl-ketone, methyl acetone,
diacetone, alcohol and freon 22.
5 Skydrol and Aerosafe hydraulic uid; acetone and somealcohols (ethyl, methyl, and isopropyl).
5A. Also suitable for these uids if Viton static seals arereplaced with EPR; specify modication number 51331 (no
extra charge); e.g., 51331-MDTV-5. Most phosphate ester-based uids solidify at approximately 30000 psi.
6 Deionized water; demineralized water.
Note: Dynamic seal life with non-lubricating fluids willunderstandably be less than with lubricating types.
O p er a t i n g T em p er a t u r es
Drive Section
-4° (25°F) to +65°C (150°F) (low temperature seals are available
for Arctic operation).
Liquid Section
For reasonable seal life, high temperature should be limited to 54° C (130° F), for F and W seal models, 135° C (275° F) for T
and TV models (with distance piece).
Services
hp Model 1 2 3 4 5 5A 6
.33
M •MS • •MDTV • • •MDSTV • • • • •MCPV • • • • •29723 • • • • •
.75 4B -14 to -37 •4B -55 to -150 • •
1.52
2.2
AW •ASF • •DF • • •DSF • • • • •HF •HSF • •DHF • •DSHF • • • •DSTV • • • • •ATV • •DTV • • •DSTV -1.5 • • • • • •AFD •DFD • • •ASFD • •DSFD • • • • •DXHF • •DSXHF • • • •DSXHW • •
3 ASFD • •
6
GW •GSF • •DGF • • •DGSF • • • • •DGSTV • • • • •GWD •GSFD • •DGFD • • •DGSFD • • • • • •DGSTVD • • • • •
8
8FD •8SFD • • • • •8DFD •8DSFD • •8DSTVD • • •8HSFD • • • • •
10
D14STD -125 • • • • •D14STD -315 • • • • •D14SFD -125 • • • • •D14SFD -315 • • • • •
8/9/2019 Bomba Haskel..
18/24www.haskel.com
33 h p ( . 25 kW) M S er i es P u m p M o d e l s
Net weight 2.65 kg
Boxed weight 2.9 kg
Box size 23 x 18 x 12 cm
M-7, M-12approx. weight 9 lbs (4 kg)
MS-7, MS-12approx. weight 9 lbs
NB. Plan view of
M-Pump is common to
all M-Series pumps.
MS-21, MS-36, MS-71,MS-110, MS-188, MS-220approx. weight 6 lbs (2.7 kg)
M-21, M-36, M-71, M-110,M-188 approx. weight 6 lbs(2.7 kg)
Net weight 4 kg
Boxed weight 4.25 kg
Box size 23 x 18 x 12 cm
Net weight 2.5 kg
Boxed weight 2.75 kg
Box size 23 x 18 x 12 cm
Net weight 6 kg
Boxed weight 6.5 kg
Box size 30 x 20 x 15 cm
M-5 approx. weight 9 lbs (4 kg)
Weights andDimensions
8/9/2019 Bomba Haskel..
19/24
75 h p ( . 56 kW) P u m p M o d e l s
MDSTV-5Approx weight 15 1/2 lbs (7 kg)29723-21, 29723-36, 29723-71, 29723-110approx. weight 6.5 lbs (3 kg)
Model 4B-14, 4B-21, 4B-25,4B-30 and 4B-37
Model 4B-55 through4B-150
www.haskel.com
8/9/2019 Bomba Haskel..
20/24
1.5 and 2 hp low ratio pumps;-B10 and -B15 ratios
Net weight 10 kg
Boxed weight 11 kg
Box size 37 x 37 x 38 cm
. 5 h p , 2 & 2 . 2 h p ( 1 . 12 , 1 . 49 & 1 . 64 kW) P u m p M o d e l s
www.haskel.com
DSFD-B60
1.5 and 2 hp medium ratio pumps;-52, -72, -122, -202 and -302 ratios
Net weight 14 kg
Boxed weight 15 kg
Box size 52 x 40 x 40 cm
1 ⁄ 4 HP port (-202, -302)
(-52, -72, +22)
1.5 and 2 hp high ratio pumps;-683 and -903 ratios
Net weight 18 kg
Boxed weight 20 kg
Box size 68 x 42 x 50 cm
25.4 mm = 1 inch
2 & 2.2 hp (1.49 & 1.64 kW) Pump Models
8/9/2019 Bomba Haskel..
21/24
1.5 and 2 hp medium and high ratios; -25 through -150, -151, -225, -300 and -450 ratios
ASFD-15
ASFD-202
ASFD-25
ASFD-35,ASFD-60ASFD-100ASFD-150
3 ⁄ 8" med.pressure}
AFD or ASFD, -B60, -B100 pumps;double acting, high output
Net weight 18 kg
Boxed weight 19 kg
Box size 45 x 37 x 44 cm
Net weight 10 kg
Boxed weight 11 kg
Box size 45 x 37 x 44 cm
3 h p ( 2 . 24 kW) P u m p M o d e l s
DSTV-1.5 pump; singleacting, high output
ATV-4 pumps; double acting, high output
Note: For model DTV-4, add distance piece dimension from page 11.
Interconnecting inlet and outlet port tubing shown.
Net weight 9.5 kg
Boxed weight 10 kg
Box size 25 x 26 x 22 cm
www.haskel.com
8/9/2019 Bomba Haskel..
22/24
If interconnecting piping for the two inlets and two outlets
is required, specify modication 29078 with your order.
Net weight 66 lbs (30 kg)Boxed weight 75 lbs (34 kg)
Box size 91 x 51 x 39 cm
Models DGFD, DGSFD, DGSTVD nominal ratio 12:1
www.haskel.com
6 h p ( 4 . 47 kW) P u m p M o d e l s
8/9/2019 Bomba Haskel..
23/24
Approx. net weight 320 lbs (145 kg)
Note: See 29079 interconnecting tubing optional page 15. (29079 shown)
Single Inlet port – 3 ⁄ 4 JIC male flare connection, single outlet port 3 ⁄ 8 HP ports (BuTech).
Individual Pump ports – Liquid inlets 2 ea. 1 ⁄ 2 NPT ports, 2 ea. 3 ⁄ 8 HP ports (BuTech)
www.haskel.com
8 h p ( 5 . 97 kW) P u m p M o d e l s
0 h p ( 7 . 46 kW) P u m p M o d e l s
Model Length Width Height Weight Air Drive Liquid Inlet Liquid Outlet
8FD-258SFD-25
25 3 ⁄ 8” (644.5 mm) 9 1 ⁄ 2” (241 mm) 11” (279 mm) 80 lbs (36 kg) 3 ⁄ 4” 1 1 ⁄ 4” NPT(2) 3 ⁄ 4” NPT(2)
8DFD-25
8DSFD-258DSTVD-25
34 3 ⁄ 4” (883 mm) 9 1 ⁄ 2” (241 mm) 11” (279 mm) 94 lbs (43 kg) 3 ⁄ 4” 1 1 ⁄ 4” NPT(2) 3 ⁄ 4” NPT(2)
8SFD-40 26 7 ⁄ 8” (683 mm) 9 1 ⁄ 2” (241 mm) 11” (279 mm) 64 lbs (29 kg) 3 ⁄ 4” 1” NPT 3 ⁄ 8” NPT
8SFD-65 26 7 ⁄ 8” (683 mm) 9 1 ⁄ 2” (241 mm) 11” (279 mm) 63 lbs (28.5 kg) 3 ⁄ 4” 1” NPT 1 ⁄ 2” NPT
8HSFD-225 28 3 ⁄ 8” (721) 9 1 ⁄ 2” (241 mm) 11” (279 mm) 71 lbs (32 kg) 3 ⁄ 4”
3 ⁄ 8” M/P (20K conedand threadedconnection)
3 ⁄ 8” M/P (20K conedand threadedconnection)
8DSFD-100 41 3 ⁄ 4” (1060 mm) 9 1 ⁄ 2” (241 mm) 11” (279 mm) 92 lbs (42 kg) 3 ⁄ 4” 1 1 ⁄ 4” NPT(2) 3 ⁄ 4” NPT(2)
8/9/2019 Bomba Haskel..
24/24
CELEBRATI NG OVER 60
YEARS OF HYDRAULIC AND
PNEUMATIC ENGINEERING
EXPERIENCE IN THE DESIGN
AND MANUFACTURING
OF HIGH PRESSURE
GENERATING EQUIPMENT
AND CO NTRO LS
For fur ther in format ion on Haske l
p r o d u c t s , p l e a s e v i s i t u s o n l i n e a tw w w . h a s k e l . c o m
H a s k e l I n t e r n a t i o n a l , I n c .
100 East Graham Place
Burbank, California 91502 USA
Tel: 818-843-4000 / Fax: 818-556-2549 or 818-841-4291
www.haskel.com
H a s k e l E u r o p e L t d .North Hylton Road
Sunderland SR5 3JD, England, UK
Tel: 44-191-549-1212 / Fax: 44-191-549-0911
www.haskel-europe.com
H a s k e l M i d d l e E a s t
Hamilton Sundstrand Industrial ME FZE
P.O. Box 262384 Jebel Ali, Dubai, United Arab Emirates
Tel: +971 4886 2686 / Fax: +971 4886 2687
Email: [email protected]
H a s k e l A s i a
Hamilton Sundstrand Singapore Industrial Pte. Ltd.
23 Tagore Lane #03-06
Tagore 23 Warehouse Complex, Singapore 787601
Tel: 65-6455-7559 / Fax: 65-6455-2841
www.haskel.com.sg
Q05225EMS511920