Eagle Quantum PremierController
PointWatch Eclipse IR Combustible Gas Detector
X3301 Multispectrum IR Flame Detector
Reliable SafetyDet-Tronics Eagle Quantum Premier system provides the power andflexibility to fully integrate high quality, certified devices in a faulttolerant network. This ensures that your system is always available to respond to a demand:
Worldwide approvals
Market Leading Detectors
Low Installation Cost
Low Maintenance
The Highest Product Quality
DET-TRONICSDetector Electronics Corporation
6901 West 110th Street Minneapolis, Minnesota 55438 USA
T: 952.941.5665 or 800.765.3473F: 952.829.8750
W: http://www.det-tronics.comE: [email protected]
92-1037-08
Provides System Solutions for:
Fire Detection
Extinguishing Agent Release
Notification
Hazardous Gas Monitoring
Fire & Gas Data Acquisition
Eagle Quantum PremierA Total Life Safety System.Certified by FM (Approved to NFPA-72), CSA and CENELEC.
Sounder
Beacon
2. Safety System Software (S3)
Smoke Detector
Cylinder
Local Operating Network/Signaling Line Circuit (LON/SLC) Devices
Catalytic Combustible Gas Sensor
7. Single Frequency IR Flame Detector (X9800)
8. UV/IR Flame Detector (X5200) 9. UV Flame Detector (X2200)
12. Enhanced Discrete Input/Output Module (EDIO)
11. Initiating Device Circuit (IDC)
14. Signal Audible Module (SAM)
1. Eagle Quantum Premier Controller (EQP)
The heart of the safety system, a multi-channel programmable
controller that manages, maintains, monitors and controls the safety
system devices on the loop. Simplex or redundant operation available.
2. Safety System Software (S3)
The software provides a seamless configuration and monitoring
package to provide a user friendly accurate environment to manage
the safety system.
3. Local Operating Network/Signaling Line Circuit (LON/SLC)
A two wire digital communication network, arranged as a fault-
tolerant loop starting and ending at the EQP controller. The LON/SLC
supports up to 246 intelligent field devices distributed over a distance
up to 32,500 feet (10,000 meters).
4. PointWatch Eclipse IR Combustible Gas Detector
Provides accurate detection of flammable hydrocarbon gases in the
lower explosive limit (LEL) range.
5. Digital Communication Unit (DCUEX)
Use with Det-Tronics catalytic combustible gas sensors and allows one
person non-intrusive calibration.
6. Multispectrum IR Flame Detector (X3301)
Provides superior performance using advanced multi patented signal
processing algorithms to ensure continuous protection in the presence
of false alarm sources.
7. Single Frequency IR Flame Detector (X9800)
Uses patented signal processing (TDSA) and narrow frequency
bandpass filters to detect radiation characteristics of hydrocarbon fires.
8. UV/IR Flame Detector (X5200)
Provides accurate fire detection by correlating the signals from both
UV and IR sensors.
9. UV Flame Detector (X2200)
An optical flame detector that uses advanced signal processing with
high speed capabilities.
10. X3302 Multispectrum IR Flame Detector
Uses patented signal processing to detect hydrogen and other invisible
fires.
11. Initiating Device Circuit (IDC)
Accepts two discrete inputs from any contact device such as smoke
and heat detectors or manual call stations. Provides two ANSI/NFPA 72
Class B Style B supervised input circuits.
12. Enhanced Discrete Input/Output Module (EDIO)
Provides eight channels configured as either discrete input, discrete
output, smoke detector, Class A output or Class A input. Each point
can be programmed for supervised or unsupervised operation.
13. Agent Release Module (ARM)
Provides agent release capability by monitoring and controlling two
output devices (rated for 24 vdc) which are energized together.
14. Signal Audible Module (SAM)
Provides two supervised indicating circuits for controlling UL Listed 24
vdc polarized audible or visual indicating appliances.
15. Relay Output Module (RM)Provides eight relay output channels to be used on non-supervised
devices.
16. Analog Input Module (AIM)
Provides eight independent 4 to 20 mA input channels that can be set
for either combustible gas mode or universal mode.
17. Intelligent Protection Module (IPM)
The IPM has preassigned functions necessary to deliver a single
protection hazard solution.
13. Agent Release Module (ARM)
Manual Call Station
Beacon
15. Relay Output Module (RM)
5. Digital Communication Unit (DCUEX)
4. PointWatch Eclipse IR Combustible Gas Detector
6. Multispectrum IR Flame Detector (X3301)
17. Intelligent Protection Module(IPM)
16. Analog Input Module (AIM)3. Local Operating Network/Signaling Line Circuit (LON/SLC)
10. Multispectrum IR Flame Detector (X3302)
1. Eagle Quantum Premier Controller (EQP)
Heat Detector
/ColorImageDict > /JPEG2000ColorACSImageDict > /JPEG2000ColorImageDict > /AntiAliasGrayImages false /CropGrayImages true /GrayImageMinResolution 300 /GrayImageMinResolutionPolicy /OK /DownsampleGrayImages true /GrayImageDownsampleType /Bicubic /GrayImageResolution 300 /GrayImageDepth -1 /GrayImageMinDownsampleDepth 2 /GrayImageDownsampleThreshold 1.50000 /EncodeGrayImages true /GrayImageFilter /DCTEncode /AutoFilterGrayImages true /GrayImageAutoFilterStrategy /JPEG /GrayACSImageDict > /GrayImageDict > /JPEG2000GrayACSImageDict > /JPEG2000GrayImageDict > /AntiAliasMonoImages false /CropMonoImages true /MonoImageMinResolution 1200 /MonoImageMinResolutionPolicy /OK /DownsampleMonoImages true /MonoImageDownsampleType /Bicubic /MonoImageResolution 1200 /MonoImageDepth -1 /MonoImageDownsampleThreshold 1.50000 /EncodeMonoImages true /MonoImageFilter /CCITTFaxEncode /MonoImageDict > /AllowPSXObjects false /CheckCompliance [ /None ] /PDFX1aCheck false /PDFX3Check false /PDFXCompliantPDFOnly false /PDFXNoTrimBoxError true /PDFXTrimBoxToMediaBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXSetBleedBoxToMediaBox true /PDFXBleedBoxToTrimBoxOffset [ 0.00000 0.00000 0.00000 0.00000 ] /PDFXOutputIntentProfile () /PDFXOutputConditionIdentifier () /PDFXOutputCondition () /PDFXRegistryName () /PDFXTrapped /False
/Description > /Namespace [ (Adobe) (Common) (1.0) ] /OtherNamespaces [ > /FormElements false /GenerateStructure true /IncludeBookmarks false /IncludeHyperlinks false /IncludeInteractive false /IncludeLayers false /IncludeProfiles true /MultimediaHandling /UseObjectSettings /Namespace [ (Adobe) (CreativeSuite) (2.0) ] /PDFXOutputIntentProfileSelector /NA /PreserveEditing true /UntaggedCMYKHandling /LeaveUntagged /UntaggedRGBHandling /LeaveUntagged /UseDocumentBleed false >> ]>> setdistillerparams> setpagedevice