2
Flash and flicker caused by power grid overload can: Cause voltage anomalies Kill an HVAC system Cause motor damage and burnout Cause compressor short cycle Install the WAGNER DSP-1 Single Phase Line Voltage Monitor to help save your compressor. 800-995-2222 Fax 770-593-8600 www.diversitech.com A trusted name for over 25 years.

Dsp 1 (Monofasico)

  • Upload
    alperda

  • View
    25

  • Download
    0

Embed Size (px)

DESCRIPTION

Protector de Motores

Citation preview

Page 1: Dsp 1 (Monofasico)

Flash and flicker caused bypower grid overload can:

• Cause voltage anomalies• Kill an HVAC system• Cause motor damage and burnout• Cause compressor short cycle

Install the WAGNER DSP-1 SinglePhase Line Voltage Monitorto help save your compressor.

800-995-2222 • Fax 770-593-8600 • www.diversitech.com

A trusted name for over 25 years.

Page 2: Dsp 1 (Monofasico)

Digital Single Phase Line Voltage Monitor

2530 Lantrac Court • Decatur, GA 30035 • 800-995-2222 • Fax 770-593-8600 • www.diversitech.com

Wagner’s Single Phase Motor Protector should be used in addition to, and not as a replacement for lightning protection systems.Wagner warrants the Single Phase Motor Protector to be free of defects and to operate per our specifications. In case of productfailure, Wagner Manufacturing will be liable for only the replacement cost of the Single Phase Motor Protector. Specificationsand product improvements subject to change at the manufacturer’s discretion.

FEATURES:• Digital voltmeter displays instantaneous line voltage• Automatic voltage tester adjusts from 90 to 300 volts• Adjustable response timer (0.1 to 10 sec.) prevents nuisance tripping• Adjustable delay on break (DOB) timer (1 to 720 sec.) prevents rapid re-starts• Off, Auto, On settings for operation with or without control inputs• Digital display makes for easy viewing and operation

FACTORY SETTINGS:208 volts 12% tolerance30 second DOB lockout 2 second response 0 second delayControl: auto

SPECIFICATIONS:Voltmeter: 90 to 300 VoltsAccuracy: + / - 2% of indicated average voltageTolerance Limits: 12 or 18%Response Timer: 0.1 to 10 secondsDOB Timer: 1 to 720 secondsOutput Relay: 10 Amps, 220 VAC resistive, single-pole/double-throwControl Input: 18 to 250 VAC

The DSP-1 is an automatic digitalvoltage monitor and control system.By continuously measuring the in-coming line voltage, this monitorwill detect voltages outside of thetolerance that you set. If theselimits are exceeded, the responsetimer is started. This timer maybe set to a long time value toavoid nuisance tripping, or to ashort time value to offer a higherlevel of load protection. If the voltage remainsoutside of the selected tolerance after the time has elapsed,the DSP-1 will turn off its output relay and protect your device.While the load is off, an additional lockout timer is activated to avoid rapid restarts.

Hard Start KitsDST-5 STARTER POWERPACK, 300% TORQUEMULTIPLIERTotally solid state, our DST-5 is justright for all permanent split capacitor(PSC) compressors from 1/2 to 10H.P. It can be used on units thatoperate on 120 through 288 Volts.

DST-6 SUPER BOOST, 500% TORQUE MULTIPLIERThe Super Boost offers a larger capacitor for severely hard-to-start compressors.The DST-6 can be used on all PSC single phase compressors from 1/2 to 10 H.P.

DST-8 SUPER BOOST 8, 690% TORQUE MULTIPLIERThe Super Boost 8 has the features of a potential relay and the benefits of easytwo wire hookup. It is a unique combination of relay and safety timer. Thecapacitor is automatically disconnected in 0.5 seconds if the compressor fails tostart. Use on all PSC single phase compressors from 1/2 to 10 H.P.

Wet Switch Flood DetectorWagner’s Wet Switch is a solid state controldesigned to help prevent flooding, damageto carpets, walls, furniture, ceilings, etc.The Wet Switch turns your system offwhen moisture is detected due tocondensate or drain leaks. As fewas one or two drops will cause a WetSwitch to turn off a unit, thereby alertinga serviceman to a moisture problem. A litLED indicates the Wet Switch is activated and hasturned the unit off. Reset simply by drying the absorbent pad with a paper toweland momentarily interrupting the power. More than one unit may be connectedto a systsem. Simple three wire installation.

WS-1

Residential Protection Kit1) Digital Single Phase Line Voltage Monitor2) Hard Start Kit3) Wet Switch Flood Detector

080122