24
Electrical impedance tomography using equipotential line method (A new approach to Inverse Conductivity Problem) (A new approach to Inverse Conductivity Problem) (A new approach to Inverse Conductivity Problem) (A new approach to Inverse Conductivity Problem) June-Yub Lee (Ewha), Ohin Kwon (Konkuk), Jeong-Rock Yoon (RPI)

Electrical impedance tomography usingequipotentialline methodmath.ewha.ac.kr/~jylee/Paper/equi02.pdf · Electrical impedance tomography usingequipotentialline method (A new approach

  • Upload
    others

  • View
    20

  • Download
    3

Embed Size (px)

Citation preview

Page 1: Electrical impedance tomography usingequipotentialline methodmath.ewha.ac.kr/~jylee/Paper/equi02.pdf · Electrical impedance tomography usingequipotentialline method (A new approach

Electrical impedance tomographyusing equipotential line method(A new approach to Inverse Conductivity Problem)(A new approach to Inverse Conductivity Problem)(A new approach to Inverse Conductivity Problem)(A new approach to Inverse Conductivity Problem)

June-Yub Lee (Ewha),

Ohin Kwon (Konkuk),

Jeong-Rock Yoon (RPI)

Page 2: Electrical impedance tomography usingequipotentialline methodmath.ewha.ac.kr/~jylee/Paper/equi02.pdf · Electrical impedance tomography usingequipotentialline method (A new approach

Physical Background(Forward) Conductivity Problem

Ω∂=∂∂=

ΩΩ∈

ongnuORfu

tsinxufindxxgivenFor..)(

,),(σ

0=∇⋅∇ uσ

Inverse Conductivity Problem

Ω∂=∂∂= ongnuANDfu

givenfromxFind )(σ

Ω∂),( gf

Page 3: Electrical impedance tomography usingequipotentialline methodmath.ewha.ac.kr/~jylee/Paper/equi02.pdf · Electrical impedance tomography usingequipotentialline method (A new approach

Impedance~Voltage/Current

Tomography

Electrical Impedance Electrical Impedance Electrical Impedance Electrical Impedance TomographyTomographyTomographyTomography (EIT)(EIT)(EIT)(EIT)

Page 4: Electrical impedance tomography usingequipotentialline methodmath.ewha.ac.kr/~jylee/Paper/equi02.pdf · Electrical impedance tomography usingequipotentialline method (A new approach

생체조직의저항률 (20-100KHz)

10

100

1000

10000

100000

체액

혈장

혈액

근육(횡

방향) 간팔근육

신경조직

심장근육

근육(종

방향) 폐

지방 뼈

최소값

최대값

[Ω-cm]

Page 5: Electrical impedance tomography usingequipotentialline methodmath.ewha.ac.kr/~jylee/Paper/equi02.pdf · Electrical impedance tomography usingequipotentialline method (A new approach

경혈 및 경락의 전기적 특성

가 설

경혈과 경락 전기저항이낮은 지점이다.

즉, 조직의저항률이 낮다.

Page 6: Electrical impedance tomography usingequipotentialline methodmath.ewha.ac.kr/~jylee/Paper/equi02.pdf · Electrical impedance tomography usingequipotentialline method (A new approach

A model problem with heart and lungA model problem with heart and lungA model problem with heart and lungA model problem with heart and lung

Page 7: Electrical impedance tomography usingequipotentialline methodmath.ewha.ac.kr/~jylee/Paper/equi02.pdf · Electrical impedance tomography usingequipotentialline method (A new approach

Methods of EIT/ICP

gnuuxuf kkMin =

∂∂=∇⋅∇−∑ ,0 where)( Objective 2

σσσ

σ

voltagefi =currentgi =

)(xσ

• Single Measurement⇒ minimum information

• Many Measurement⇒ full information(?) on σ

• Infinite Measurement⇒ mathematical theory

Page 8: Electrical impedance tomography usingequipotentialline methodmath.ewha.ac.kr/~jylee/Paper/equi02.pdf · Electrical impedance tomography usingequipotentialline method (A new approach

Numerical Obstacles for EIT/ICP

σσ

σ

σσ

σσσ

~better Find ,0 Solve Guss

,0 where)()( Objective)(2

→=∂∂=∇⋅∇→

=∂∂=∇⋅∇−∑ Ω

gnuuσ(x)

gnuuxuxf

LMin

• Strongly nonlinear:

• Ill-posed problem:

)()( 22 Ω∂∈→Ω∈ LuL σσ

σσσσ ~~ uu ≈→≈/

fugnuu −→=∂∂=∇⋅∇ σ

σσ σσ using ~better Find ,0 Solve

σσ on on restrictiu Regularity 0condition Stop →≅− fu

Page 9: Electrical impedance tomography usingequipotentialline methodmath.ewha.ac.kr/~jylee/Paper/equi02.pdf · Electrical impedance tomography usingequipotentialline method (A new approach

Ill-posed Nonlinear

• 50 iterations

Page 10: Electrical impedance tomography usingequipotentialline methodmath.ewha.ac.kr/~jylee/Paper/equi02.pdf · Electrical impedance tomography usingequipotentialline method (A new approach

EIT and MREIT(Magenetic Resonace Electrical Impedance Tomography)

0.95 mA

Current SourceVoltmeter

Page 11: Electrical impedance tomography usingequipotentialline methodmath.ewha.ac.kr/~jylee/Paper/equi02.pdf · Electrical impedance tomography usingequipotentialline method (A new approach

변수형 고속 영상복원 알고리즘

진단 변수 추출

심폐기능소화기능배뇨기능뇌기능

비정상 조직 검출기타 변수

실시간실시간영상영상 모니터링모니터링

MREIT고해상도 영상

적응형 요소융합및 세분화

변수형 고속알고리즘

초기해초기해초기해초기해

Page 12: Electrical impedance tomography usingequipotentialline methodmath.ewha.ac.kr/~jylee/Paper/equi02.pdf · Electrical impedance tomography usingequipotentialline method (A new approach

(1)문제정의

(2)자속밀도의 영상화

MRCDI 및 MREIT의 원리

1E2EΩ

∂Ω

( ), , ,Vρ J BI I

n3 \ Ω

L− L+

a

1 ( ) 0( )

∇ ∇ =

r

r1 on V J

nρ∂ = ∂Ω∂

1( ) ( )( )

= − ∇J r rr

03'( ) ( ') '

4 'J dvµ

π Ω

−= ×−∫

r rB r J rr r

30

3\

03

'( ) ( ') ( ') '4 '

'( ') ( ') '4 '

I

L

dv

I dl

µπ

µπ

±

±

Ω

−= ×−

−= ×−

r rB r J r a rr r

r rr a rr r

0

1( ) ( )B

µ= ∇×J r B r

1E

2E

x

yz

x yz

1E

2E

1E

2E

x

yz

Transversal ImagingSlice

Three Sagittal ImagingSlices

Three Coronal ImagingSlices

Page 13: Electrical impedance tomography usingequipotentialline methodmath.ewha.ac.kr/~jylee/Paper/equi02.pdf · Electrical impedance tomography usingequipotentialline method (A new approach

전류밀도 영상 실험용 팬텀

Page 14: Electrical impedance tomography usingequipotentialline methodmath.ewha.ac.kr/~jylee/Paper/equi02.pdf · Electrical impedance tomography usingequipotentialline method (A new approach

자속밀도 및 전류밀도 영상

y

z

]Tesla[

y

z

]Tesla[

x

z

]Tesla[

x

z

]Tesla[

x

y

]Tesla[

x

y

]Tesla[

Bx By

Bz

]mA/mm[ 2

x

y

]mA/mm[ 2 ]mA/mm[ 2

x

y

|J|0

= ∇×J B

Page 15: Electrical impedance tomography usingequipotentialline methodmath.ewha.ac.kr/~jylee/Paper/equi02.pdf · Electrical impedance tomography usingequipotentialline method (A new approach

자속밀도 및 전류밀도 영상

Page 16: Electrical impedance tomography usingequipotentialline methodmath.ewha.ac.kr/~jylee/Paper/equi02.pdf · Electrical impedance tomography usingequipotentialline method (A new approach

J-Substitution Algorithm

OriginalConductivity

ReconstructedConductivity

Current Density

Page 17: Electrical impedance tomography usingequipotentialline methodmath.ewha.ac.kr/~jylee/Paper/equi02.pdf · Electrical impedance tomography usingequipotentialline method (A new approach

Schematic Diagram for Equi-potential Line Method

Page 18: Electrical impedance tomography usingequipotentialline methodmath.ewha.ac.kr/~jylee/Paper/equi02.pdf · Electrical impedance tomography usingequipotentialline method (A new approach

Numerical Algorithm

Page 19: Electrical impedance tomography usingequipotentialline methodmath.ewha.ac.kr/~jylee/Paper/equi02.pdf · Electrical impedance tomography usingequipotentialline method (A new approach

Equipotential Line Method

Page 20: Electrical impedance tomography usingequipotentialline methodmath.ewha.ac.kr/~jylee/Paper/equi02.pdf · Electrical impedance tomography usingequipotentialline method (A new approach

Smooth conductivity distribution

Page 21: Electrical impedance tomography usingequipotentialline methodmath.ewha.ac.kr/~jylee/Paper/equi02.pdf · Electrical impedance tomography usingequipotentialline method (A new approach

Conductivity Result with noisy J

Page 22: Electrical impedance tomography usingequipotentialline methodmath.ewha.ac.kr/~jylee/Paper/equi02.pdf · Electrical impedance tomography usingequipotentialline method (A new approach

Phantom with 1%Add+10%Mul Noise

Page 23: Electrical impedance tomography usingequipotentialline methodmath.ewha.ac.kr/~jylee/Paper/equi02.pdf · Electrical impedance tomography usingequipotentialline method (A new approach

Artificially generated Human Body

1%Add+10%Mul Noise

Page 24: Electrical impedance tomography usingequipotentialline methodmath.ewha.ac.kr/~jylee/Paper/equi02.pdf · Electrical impedance tomography usingequipotentialline method (A new approach

Conclusions and further works• Fast, stable and efficient• Well-posed (error~noise)• Better interpolation method to handle discontinuous cases

• Noise handling for high conductivity ratio case where |J|~0

• 3D extension is trivial But 3D data for J is expensiveUsage of Bz instead of J is better