1 High repetition rate SLR at GRSM C. Courde 1 , H. Mariey 1 , J. Chabé 1 , D-H. Phung 1 , J-M. Torre 1 , M. Aimar 1 , N. Maurice 1 , E. Samain 2 , A. Tosi 3 , M. Buttafava 3 1 Université Côte d'Azur, CNRS, Observatoire de la Côte d'Azur, IRD, Géoazur, 2130 Route de l’Observatoire 06460 CAUSSOLS France 2 SigmaWorks, 8 Allée Bellevue 06460 SAINT VALLIER DE THIEY, France 3 Politecnico di Milano, Dipartimento di Elettronica, Informazione e Bioingegneria, Piazza Leonardo da Vinci 32, 20133 Milano, Italy ILRS Technical Workshop Stuttgart 21th 25th October 2019

High repetition rate SLR at GRSM - NASADCR @ 7 V 200 kHz Quantum efficiency 47% @ 1064 nm Development of two high repetition rate SPAD detections And with the help of the High repetition

  • Upload
    others

  • View
    3

  • Download
    1

Embed Size (px)

Citation preview

Page 1: High repetition rate SLR at GRSM - NASADCR @ 7 V 200 kHz Quantum efficiency 47% @ 1064 nm Development of two high repetition rate SPAD detections And with the help of the High repetition

1

High repetition rate SLR at GRSM

C. Courde1, H. Mariey1, J. Chabé1, D-H. Phung1, J-M. Torre1, M. Aimar1, N. Maurice1,

E. Samain2, A. Tosi3, M. Buttafava3

1 Université Côte d'Azur, CNRS, Observatoire de la Côte d'Azur, IRD, Géoazur, 2130 Route de

l’Observatoire 06460 CAUSSOLS France2 SigmaWorks, 8 Allée Bellevue 06460 SAINT VALLIER DE THIEY, France3 Politecnico di Milano, Dipartimento di Elettronica, Informazione e Bioingegneria, Piazza

Leonardo da Vinci 32, 20133 Milano, Italy

ILRS Technical Workshop

Stuttgart 21th – 25th October 2019

Page 2: High repetition rate SLR at GRSM - NASADCR @ 7 V 200 kHz Quantum efficiency 47% @ 1064 nm Development of two high repetition rate SPAD detections And with the help of the High repetition

2

Why increasing the repetition rate ?

Our motivation: 2 colors measurement at the mm level

2𝐷 = 𝑅𝐺𝑟𝑒𝑒𝑛+ a (𝑅Green – 𝑅IR)

=>

It requires an high improvement of the time-of-flight measurement on the both

wavelength.

D

RGreenRIR

Page 3: High repetition rate SLR at GRSM - NASADCR @ 7 V 200 kHz Quantum efficiency 47% @ 1064 nm Development of two high repetition rate SPAD detections And with the help of the High repetition

3

Why increasing the repetition rate ?

Limitations : - Multi corner cubes

target

- Timing jitter of SPAD

=> 𝜎 𝑠𝑖𝑛𝑔𝑙𝑒−𝑠ℎ𝑜𝑡 = 15 𝑝𝑠

- Atmospherical

dispersion & spectral

width of pulses

=> limit the use of

pulse width between

5 ps - 20 ps

Limitations : - Atmospherical backscattering &

turbulence

[I. Prochazka, 17th ILRS Workshop, 2011]

One solution in single-photon mode:

Try to increase the repetition rate of the

measurements to push the TVAR on the

left

Page 4: High repetition rate SLR at GRSM - NASADCR @ 7 V 200 kHz Quantum efficiency 47% @ 1064 nm Development of two high repetition rate SPAD detections And with the help of the High repetition

4

What is it necessary to implemented ?

▪ Time Stability @ 1000s: < 20 fs

▪ Linearity: 0.3 ps rms.

▪ Thermal Sensit. < 200 fs/°C

▪ Repeatability error

▪ Synchronous : 600 fs rms

▪ Random : 700 fs rms

▪ Rate

▪ Dead time: 130 ns

▪ Continuous rate 35 kHz

We have a

sub-picosecond STX 301 event timer

(puchased now by SigmaWorks) acquired

during the T2L2 mission.

High repetition rate picosecond laser => 100 MHz HighQ laser

High repetition rate event timer

Page 5: High repetition rate SLR at GRSM - NASADCR @ 7 V 200 kHz Quantum efficiency 47% @ 1064 nm Development of two high repetition rate SPAD detections And with the help of the High repetition

5

Collaboration in 2014 with

Si-SPAD

Active area diameter 100 µm

Max repetition rate 1 MHz

Timing jitter 33 ps FWHM

DCR @ 7 V 74 Hz

Quantum efficiency 53% @ 532 nm

What is it necessary to implemented ?

InGaAs-SPAD

Active area diameter 50 µm

Max repetition rate 100 kHz

Timing jitter 76 ps FWHM

DCR @ 7 V 200 kHz

Quantum efficiency 47% @ 1064 nm

Development of two high repetition rate SPAD detections

And with the help of the

High repetition rate SPAD

Page 6: High repetition rate SLR at GRSM - NASADCR @ 7 V 200 kHz Quantum efficiency 47% @ 1064 nm Development of two high repetition rate SPAD detections And with the help of the High repetition

6

Green SPAD @ 1MHz

Page 7: High repetition rate SLR at GRSM - NASADCR @ 7 V 200 kHz Quantum efficiency 47% @ 1064 nm Development of two high repetition rate SPAD detections And with the help of the High repetition

7

Green SPAD @ 1MHz

Skew = 1.8 ; Kurtosis = 5.5

Clearly not a Normal distribution !

Page 8: High repetition rate SLR at GRSM - NASADCR @ 7 V 200 kHz Quantum efficiency 47% @ 1064 nm Development of two high repetition rate SPAD detections And with the help of the High repetition

8

Green SPAD @ 1MHz

Page 9: High repetition rate SLR at GRSM - NASADCR @ 7 V 200 kHz Quantum efficiency 47% @ 1064 nm Development of two high repetition rate SPAD detections And with the help of the High repetition

9

Green SPAD @ 1MHz

Page 10: High repetition rate SLR at GRSM - NASADCR @ 7 V 200 kHz Quantum efficiency 47% @ 1064 nm Development of two high repetition rate SPAD detections And with the help of the High repetition

10

Green SPAD @ 1MHz

150 fs @ 0.6 s

Page 11: High repetition rate SLR at GRSM - NASADCR @ 7 V 200 kHz Quantum efficiency 47% @ 1064 nm Development of two high repetition rate SPAD detections And with the help of the High repetition

11

IR SPAD @ 100 kHz

Page 12: High repetition rate SLR at GRSM - NASADCR @ 7 V 200 kHz Quantum efficiency 47% @ 1064 nm Development of two high repetition rate SPAD detections And with the help of the High repetition

12

IR SPAD @ 100 kHz

Skewness =0.9 ; Kurtosis = 4.2

Page 13: High repetition rate SLR at GRSM - NASADCR @ 7 V 200 kHz Quantum efficiency 47% @ 1064 nm Development of two high repetition rate SPAD detections And with the help of the High repetition

13

IR SPAD @ 100 kHz

Page 14: High repetition rate SLR at GRSM - NASADCR @ 7 V 200 kHz Quantum efficiency 47% @ 1064 nm Development of two high repetition rate SPAD detections And with the help of the High repetition

14

IR SPAD @ 100 kHz

Page 15: High repetition rate SLR at GRSM - NASADCR @ 7 V 200 kHz Quantum efficiency 47% @ 1064 nm Development of two high repetition rate SPAD detections And with the help of the High repetition

15

IR SPAD @ 100 kHz

213 fs @ 2s

Page 16: High repetition rate SLR at GRSM - NASADCR @ 7 V 200 kHz Quantum efficiency 47% @ 1064 nm Development of two high repetition rate SPAD detections And with the help of the High repetition

16

High repetition rate on a ground-

ground link

Page 17: High repetition rate SLR at GRSM - NASADCR @ 7 V 200 kHz Quantum efficiency 47% @ 1064 nm Development of two high repetition rate SPAD detections And with the help of the High repetition

17

Laser ranging on a fixed target at a distance of

2.5 km @ 100 kHz at 1064 nm

Page 18: High repetition rate SLR at GRSM - NASADCR @ 7 V 200 kHz Quantum efficiency 47% @ 1064 nm Development of two high repetition rate SPAD detections And with the help of the High repetition

18

Laser ranging on a fixed corner cube at a

distance of 2.5 km @ 100 kHz at 1064 nm

Modulo 1E7 fs => 10 ns

Residuals from the non complete extinction of

the pulse picker in front of the 100 MHz

repetition rate laser

Page 19: High repetition rate SLR at GRSM - NASADCR @ 7 V 200 kHz Quantum efficiency 47% @ 1064 nm Development of two high repetition rate SPAD detections And with the help of the High repetition

19

Laser ranging on a fixed corner cube at a

distance of 2.5 km @ 100 kHz at 1064 nm

Page 20: High repetition rate SLR at GRSM - NASADCR @ 7 V 200 kHz Quantum efficiency 47% @ 1064 nm Development of two high repetition rate SPAD detections And with the help of the High repetition

20

Laser ranging on a fixed corner cube at a

distance of 2.5 km @ 100 kHz at 1064 nm

Page 21: High repetition rate SLR at GRSM - NASADCR @ 7 V 200 kHz Quantum efficiency 47% @ 1064 nm Development of two high repetition rate SPAD detections And with the help of the High repetition

21

Laser ranging on a fixed corner cube at a

distance of 2.5 km @ 100 kHz at 1064 nm

300s

Page 22: High repetition rate SLR at GRSM - NASADCR @ 7 V 200 kHz Quantum efficiency 47% @ 1064 nm Development of two high repetition rate SPAD detections And with the help of the High repetition

22

Laser ranging on a fixed corner cube at a

distance of 2.5 km @ 100 kHz at 1064 nm

450 ms

Limitation of the event timer:

130 ns deadtime but limitation due to internal time

for the transfer of data and the limited size of the fifo

=> continuous rate 35 kHz max

Page 23: High repetition rate SLR at GRSM - NASADCR @ 7 V 200 kHz Quantum efficiency 47% @ 1064 nm Development of two high repetition rate SPAD detections And with the help of the High repetition

23

Laser ranging on a fixed corner cube at a

distance of 2.5 km @ 100 kHz at 1064 nm

Page 24: High repetition rate SLR at GRSM - NASADCR @ 7 V 200 kHz Quantum efficiency 47% @ 1064 nm Development of two high repetition rate SPAD detections And with the help of the High repetition

24

Laser ranging on a fixed corner cube at a

distance of 2.5 km @ 100 kHz at 1064 nm

Maybe pb with the laser lock-in on the external clock

Atmospherical turbulence ?

Page 25: High repetition rate SLR at GRSM - NASADCR @ 7 V 200 kHz Quantum efficiency 47% @ 1064 nm Development of two high repetition rate SPAD detections And with the help of the High repetition

25

Laser ranging on a fixed corner cube at a

distance of 2.5 km @ 100 kHz at 1064 nm

Average wind > 15 m/s (54 km/h)

Page 26: High repetition rate SLR at GRSM - NASADCR @ 7 V 200 kHz Quantum efficiency 47% @ 1064 nm Development of two high repetition rate SPAD detections And with the help of the High repetition

26

• We characterized two high repetition rate SPAD working:

– at 1 MHz in Green

– at 100 kHz in IR

• We measured a white noise behaviour for our two detection channels

in Lab with:

– 150 fs @ 0.6 s for the green SPAD

– 213 fs @ 2s for the IR SPAD

• We will have to confirm that high repetition rate laser ranging allow to

see the impact of the atmospherical turbulence on the range

measurements

• Lot of works in perspective on all the SLR sub-system !!

• A new laser dedicated for SLR should arrive soon !

Conclusion & Perspectives

Page 27: High repetition rate SLR at GRSM - NASADCR @ 7 V 200 kHz Quantum efficiency 47% @ 1064 nm Development of two high repetition rate SPAD detections And with the help of the High repetition

27

Thanks for your attention

Page 28: High repetition rate SLR at GRSM - NASADCR @ 7 V 200 kHz Quantum efficiency 47% @ 1064 nm Development of two high repetition rate SPAD detections And with the help of the High repetition

28

Motivation

2𝐷 = 𝑅𝐺𝑟𝑒𝑒𝑛 𝑅𝐺𝑟𝑒𝑒𝑛 =𝑡𝑟𝑒𝑡𝑢𝑟𝑛 − 𝑡𝑠𝑡𝑎𝑟𝑡 . 𝑐0𝑛(𝜆, 𝑇, 𝑃𝑣, 𝑃𝑎, 𝐶𝑂2)

Currently:

RGreen

D

with

Unknown parameter

=> uncertainty at the cm level

Page 29: High repetition rate SLR at GRSM - NASADCR @ 7 V 200 kHz Quantum efficiency 47% @ 1064 nm Development of two high repetition rate SPAD detections And with the help of the High repetition

29

Motivation

Our objective: 2 colors measurement at the mm level

2𝐷 = 𝑅𝐺𝑟𝑒𝑒𝑛+ a (𝑅Green – 𝑅IR)

Correction term => Dispersion effect (due to dry atmosphere)

Page 30: High repetition rate SLR at GRSM - NASADCR @ 7 V 200 kHz Quantum efficiency 47% @ 1064 nm Development of two high repetition rate SPAD detections And with the help of the High repetition

30

Page 31: High repetition rate SLR at GRSM - NASADCR @ 7 V 200 kHz Quantum efficiency 47% @ 1064 nm Development of two high repetition rate SPAD detections And with the help of the High repetition

31

Improve accuracy in SLR

𝐷 =𝑡𝑎𝑟𝑟𝑖𝑣𝑎𝑙 − 𝑡𝑑𝑒𝑝𝑎𝑟𝑡 . 𝑐

2𝑐 =

𝑐0𝑛(𝜆, 𝑇, 𝑃𝑣, 𝑃𝑎, 𝐶𝑂2)

avec

J. B. Abshire, October 1980 / Vol. 19, No. 20 / APPLIED OPTICS

Idea of 2 colors

(K. B. Earnshaw and E. Norman

Hernandez, 1972 ; Abshire, 1980)

Send simultaneously pulses at 2 different

wavelengths.

Not used routinely by most of the

ILRS stations:

- Technological limits

- Global performances of the same

order of index models

Page 32: High repetition rate SLR at GRSM - NASADCR @ 7 V 200 kHz Quantum efficiency 47% @ 1064 nm Development of two high repetition rate SPAD detections And with the help of the High repetition

32

• ℛ1 = 𝑝1

.𝑛 𝑓1, 𝑟1 𝑑𝑠1

• ℛ2 = 𝑝2.𝑛 𝑓2, 𝑟2 𝑑𝑠2

Improve accuracy in SLR

From D. D. Wijaya et Al.,

Springer Verlag, 2011

• ℛ1 & ℛ2 contains the same quantities of total atmospheric

and water vapor density, the same curvature effects. The

unknown integral 𝑝1.𝜌𝑡 𝑟1 𝑑𝑠1 can be rigorously eliminated

2𝑆 = 𝑅1+ 𝜈 𝑅1 − 𝑅2 + 𝜐𝑃21 − 𝜅1 +𝐻21𝑆𝐼𝑊𝑉

2 colors measurement

P21 represents the propagation corrections from the ray path p2 to p1

κ1 is the arc-to-chord correction for the ray path p1 which accounts for the curvature effect

ν the power of dispersion

H21 the water vapor factor

SIWV the slant integrated water vapor

Page 33: High repetition rate SLR at GRSM - NASADCR @ 7 V 200 kHz Quantum efficiency 47% @ 1064 nm Development of two high repetition rate SPAD detections And with the help of the High repetition

33

Improve accuracy in SLR

En mm En mm En mm

Dispersion effect (term due to dry atmosphere)

Curvature of optical paths

Water vapor density effect

Page 34: High repetition rate SLR at GRSM - NASADCR @ 7 V 200 kHz Quantum efficiency 47% @ 1064 nm Development of two high repetition rate SPAD detections And with the help of the High repetition

34

How to achieve millimetric accuracy in SLR

with 2-colors measurements?

From D. D. Wijaya et

al., Springer Verlag,

2011

Precision to reach at each wavelength

Millimeter accuracy possible with a significant precision improvement