Hướng dẫn sử dụng thiết bị triệt lông

Embed Size (px)

Citation preview

  • 8/9/2019 Hng dn s dng thit b trit lng

    1/23

    HKS820User&Training Manual

    Intense Pulse LightRadio Frequency

  • 8/9/2019 Hng dn s dng thit b trit lng

    2/23

    HKS820

    User&Training Manual

    Intense Pulse LightRadioFrequency

    Intense Pulse Light Safety Guidelines

    01

    The Fo l low ing in f orm at i on is pro v id ed for the cor rec t

    uti l izati on of IPL Skin treat ment syst em.t he In formation

    inc lud es not on l y the acc ide nt pro tec t io n reg u la t io ns

    the produc ts comply with,but also the effect ive regard ing

    pro per use of the produc ts.

    1)E lec t r ic sa fe ty regu la t ion

    The EMC Dir ect ive 89/ 336 /EE C ame nde d by 92/ 31/ EC

    &93/68 /EECEN55015:2000+A1+A2/LUM200704025/

    EMCEN61000-3-2 :2000+A2/LUM200704025/EMCEN

    61000-3-3:1995+A1+A2/LUM200704025/EMCEN61547:

    1997+A1/LUM200704025/EMC

    2)Mate r ia l ROHS tes t200 2/95/EC

    Rest r ic t io n of use of cer ta in Hazard ous

    Substance in Electr ical&electronics Equipm ent/ROHS.

    3 ) E l e c t r o m a g e t i c r a d i a t i o n s a f e t y r e g u l a t i o n L V D /

    EN60601-1:2006/AGC10430904GZ05E3EMC/EN60601

    -1-2 :2001+A1:2006 /AGC10430904GZ05E1

    4) ISO13 485:200 3 MEDICAL /3302120 0005459

    5)I TC MED ICAL CE

    IPL SKIN TREATMENT SYSTEM belongs to a accord ing

    to MD D dir ect ive ,It desi gne d accord ing to EN 980 :20 03;

    EN 1041:1998; EN ISO 14971:2007; EN 60601-1-2:2007;

    EN 61000-3-2:2006; EN 61000-3-3:1995+ A1:2001+A2:

    200 6; EN 6060 1-2 -22: 199 6;

    EN 60601- 1-4-1996 +A1-199 9; EN 60601-1 :2006.

  • 8/9/2019 Hng dn s dng thit b trit lng

    3/23

    Certificate

    02

    HKS820

    User&Training Manual

    Intense Pulse LightRadioFrequency

  • 8/9/2019 Hng dn s dng thit b trit lng

    4/23

    03

    Wh y is IP L be tt er th an ot her tr eat me nt s?

    In addit ion to trea t ing mult i p le symptom s and locat io ns

    in ea ch se ss ion , IP L is ge nt l e, no n-i nv as ive an d sa fe .

    Bec aus e of th is, there is no "do wn t ime. " You see res ult s

    in the com ple xio n an d the skin t exture o f the entire f ace .

    Yo u ca n re tu rn to yo ur no rm al ro ut in es an d ac t i v i t i esimm edi ate ly. In fac t, man y peo ple even sch edu le the ir

    se ss io ns du r i ng th e i r lu nc h b r ea k . Ad d i t i on a l l y, IP L

    trea tmen ts a re custo mized to your spec ific skin type and

    col or , prov id i ng the best possib le resu l ts .

    Wh at ar ea s ca n be tr ea ted with IPL sys te ms ?

    Th e IP LS ys te m ca n re mo ve ha i r f r om a l l pa r t s o f th e

    bo dy in c l ud i ng th e fac e, leg s, ar ms , un der arm s, an dba ck . I t ca n a l so t r ea t se ns i t iv e ar ea s l i ke th e ch es t ,

    ni pp le s an d bik in i l i ne .

    Wh at do IP L tr ea tm en ts fee l l i ke ?

    As the name impl ies, the IPL hand-piece cools and sooth

    es as it gl id es al on g yo ur sk in . Wh en the pu ls e of l i gh ts

    del ive red , som e pat ien ts exp eri enc e a mi ld pin chi ng or

    stinging sensation. No local anesthes ia or pain medication

    is typic ally requi red, howev er some patie nts may prefe r

    to us e a to p i ca l an es th et ic wh en se ns i t iv e ar ea s ar e

    treated.

    Ho w ma ny tr ea tm en ts wi l l I nee d?

    Mos t areas require 3-6 treatments, but the number of IPL

    t r e a t m e n t s y o u m a y r e q u i r e f o r o p t i m a l l o n g - t e r m

    be ne fi ts de pe nds on va r i ou s fa ct or s su ch as you r ha ir

    t h i c k n e s s , t h e a r e a t r e a t e d , a n d y o u r h a i r g r o w t h

    Question

    HKS820

    User&Training Manual

    Intense Pulse LightRadioFrequency

  • 8/9/2019 Hng dn s dng thit b trit lng

    5/23

    04

    Question

    cy cl e. In te re st ing ly, not al l hai rs ar e ac t i vel y gr owi ng

    a t t h e s a m e t i m e , b u t a c t u a l l y g o t h r o u g h t h r e e

    dis t in ct pha ses ; gro wth , reg res sio n, and res t in g. IPL

    sys tem s wor k by d is ab l ing the ha i r tha t is pr i nc i pa l ly

    in th e ac t i ve gro wt h ph as e at th e t im e of tr ea tm en t.

    S i nc e o t he r ha i r s w i l l en te r th is ac t i ve gr ow th ph as ea t d i f f e r e n t t i m e s , a d d i t i o n a l t r e a t m e n t s m a y b e

    ne ce ssa ry to d i sa ble a l l o f th e hai r fo l l ic l es in a g i ve n

    area .

    Ho w is IP L us ed to tr ea t ben ig n vas cu lar lesi ons ?

    A g in g , su n ex posu re an d o t he r f ac to r s can c aus e the

    a p p e a r a n c e o f b r o k e n c a p i l l r i e s a n d b l o o d v e s s e l s

    on th e fa ce kn own as te la ngi ec ta si as , wh ic h ap pe ar asspi der vei ns. Som eti mes bro ken cap i l l ar i es can cau se

    a d iffused re dness in the skin , called eryt hema, a source

    of soc ia l embarr assm ent for man y peop le. Rosace a is

    a c o m m o n s k i n c o n d i t i o n t h a t i s c h a r a c t e r i z e d b y

    di f fus ed ery the ma. Al l o f these condi t ion s

    HKS820

    User&Training Manual

    Intense Pulse LightRadioFrequency

  • 8/9/2019 Hng dn s dng thit b trit lng

    6/23

    1.Product Information

    05

    1.PRODUCT INFORMATION

    APPLICATION

    *Hair removal

    *Skin rejuvenation

    *red face, red no se, coupe rosi s, spi der vein s.

    *age spo ts, sun spot s, pigm entat ion trou bles*Acne

    FEATURES

    *1handle

    Big hand le:15*50mm with 5f i l ter640-1200nm for hair remo val

    590-1 200nm for red f ace, red no se, coupe rosi s, sp ider vein s.

    560-1200nm f or Skin rej uvenation

    430-1 200nm for Acne

    480-1 200nm for age s pots, sun s pots, pigme ntati on tro ubles

    750-1 200nm for hair remov al in D ark Skin

    *Lamp longevity:60000shots

    *Energy:15-50J

    *Pulse Number:1-15adjust

    *Pulse Width:1.0-20.0*Pulse Delay:1-50

    *Shot per iod:2-5second adjust

    *Dis play: 8.0 inch Touch dis play

    *Vol tage: 110V or 220V

    *Power:1000W

    *Cooling system:Wind+water+semiconductor

    *RF P ower: 80W

    *Pakcge size:110*62*62cm

    *Weight:56kg

    *Skin t ightening and l i f t ing

    *Wrinkle reduct ion

    *Systemic col lagen regenerat ion

    *RF Frequency:1/3/10MH z

    *RF Pro be:2handle with 3probe

    optional

    opt ional

    opt ional

    Variable frequency

    HKS820

    User&Training Manual

    Intense Pulse LightRadioFrequency

  • 8/9/2019 Hng dn s dng thit b trit lng

    7/23

    06

    2.Installation Alignment and operation procedures

    2.1 Open the Package and checking all parts.

    2.2put the handle holder on machine by screw.then connect

    well the handle in back of machine.

    2.2 put the water to Input,when water is out of overflow means

    the water tank is full

    2.3 Put the fi lter in handle

    Crystal

    Filter

    Press the blue parts,

    then take o ut the water plug

    HKS820

    User&Training Manual

    Intense Pulse LightRadioFrequency

  • 8/9/2019 Hng dn s dng thit b trit lng

    8/23

    07

    3.Operate the Device

    3.1 Auto interface

    AUTOMAT IC MODEL

    FUNCTION MENU

    Skin Type

    Pigmentation

    Hair Thickness

    Energy

    AUTO MODEL BACK DATAOFF

    Hair removal Skin Rejuvenation

    Skin Type: - White Skin Dark Skin

    Pigmentation:None Light Medium Intense

    Hair Thickness:Thin Medium Thick

    HKS820

    User&Training Manual

    Intense Pulse LightRadioFrequency

  • 8/9/2019 Hng dn s dng thit b trit lng

    9/23

    08

    3.Operate the Device

    3.2 Manual interface

    Pulse Number

    Pulse Width

    Pulse Delay

    Release

    Energy

    TREATMENT PARAMETER

    ON MANUAL MODEL SAVE DATA

    15*50mm

    30

    30

    15

    5

    50

    Save:Save the parameter for currentRelease:time for each shot distance

    3.3 Data inter face

    BACK

    Total Counter*

    7 8 9

    4 5 6

    1 2 3

    0 Del Enter

    15*50mm

    15*50mm:current shot account,press it will be 0total couonter:all shot account,need input password for 0

    HKS820

    User&Training Manual

    Intense Pulse LightRadioFrequency

  • 8/9/2019 Hng dn s dng thit b trit lng

    10/23

    09

    3.Operate the Device

    3.3 Operating&setting

    Choice one model language in Screen.The system will enter

    Auto model.In Auto model,the system have memory right

    parameter for many trea tmen t.On ly need chice righ t Skin

    type, Pigme nt,Hai r thi chness ,then press the READY,the

    Mac hine can sta rt to work.Manual mo del ,User can i npu t

    right parameter to fi x sufferer treatment.Choice differentfilter to make different treatment.User Data show the current

    shot amount and total amount.

    Delete total shot amount need password.

    Pulse Width

    Pulse Delay

    3.4 Finish the treatment.

    Frist need press the ON in screen,make the lamp off .Then

    turn off the key switch+urgency button+main electr ic switch.

    Do not let the lamp be light when the user leave for long t ime.

    Before turn on machine,

    must take out the water

    Plug from machine back.

    HKS820

    User&Training Manual

    Intense Pulse LightRadioFrequency

  • 8/9/2019 Hng dn s dng thit b trit lng

    11/23

    10

    4.Treatment Parameter

    Dark hair by lower width

    Light hair by higher width

    thickness hair by higher delay and lower energy

    thin hair by lower delay and higher energy

    dark skin by higher delay and lower energy

    light skin by lower delay and high energyWhen add the width that can not reduce the energy

    when reduce the width that can not add the energy

    I - II

    III - IV

    none

    light

    medium

    intense

    thin

    medium

    thick

    A

    B

    1

    2

    3

    4

    C

    D

    E

    SKIN TYPE

    PIGMENTATION

    HAIR THICKNESS

    Skin rejuvenation

    A1

    A2

    A3

    A4

    B1

    B2

    B3

    B4

    1

    1

    1

    1

    2

    2

    2

    2

    9.7

    9.2

    8.8

    8.4

    9.2

    8.8

    8.4

    8.2

    0

    0

    0

    0

    10

    10

    15

    15

    28

    27

    26

    25

    26

    25

    24

    23

    Pulse Width Pulse DelayPulse Number Energy

    HKS820

    User&Training Manual

    Intense Pulse LightRadioFrequency

  • 8/9/2019 Hng dn s dng thit b trit lng

    12/23

    11

    4.Treatment Parameter

    9.5

    8.5

    7.5

    8.5

    7.5

    6.5

    7.5

    6.5

    6

    7

    6

    5.5

    9

    8

    7

    8.5

    7.5

    6.5

    7.5

    6.5

    5.5

    6.5

    6

    5.5

    Hair Removal

    Pulse Width Pulse DelayPulse Number

    A1C

    A1D

    A1E

    A2C

    A2D

    A2E

    A3C

    A3D

    A3E

    A4C

    A4D

    A4E

    B1C

    B1D

    B1E

    B2C

    B2D

    B2E

    B3C

    B3D

    B3E

    B4C

    B4D

    B4E

    1

    1

    1

    1

    1

    1

    2

    2

    2

    3

    3

    3

    3

    3

    3

    3

    3

    3

    3

    3

    3

    5

    5

    5

    36

    35

    33

    34

    33

    32

    32

    31

    30

    30

    29

    28

    35

    34

    33

    33

    32

    31

    31

    30

    29

    29

    28

    27

    Energy

    0

    0

    0

    0

    0

    0

    10

    10

    10

    15

    15

    15

    5

    5

    5

    10

    10

    10

    15

    15

    15

    17

    17

    17

    HKS820

    User&Training Manual

    Intense Pulse LightRadioFrequency

  • 8/9/2019 Hng dn s dng thit b trit lng

    13/23

    12

    5.Treatment Procedure

    5.1 Shave the hair on skin and left hair be 1-2mm.

    5.2 Put the Gel on skin,Gel Thickness is around 1mm.

    5.3 Touch wel l the crysta l on sk in.

    5.4 After treatment ,clean the Skin by warm water .

    HKS820

    User&Training Manual

    Intense Pulse LightRadioFrequency

  • 8/9/2019 Hng dn s dng thit b trit lng

    14/23

    13

    6.IPL Treatment General Knowledge

    6.1.Curative effect

    After frist one or two treatment,the hair can lost 80%.

    After 4-5 treatment,the hair will lost 95%.then no hair grow

    or less thin ha ir grow.(Acceptable)

    6.2.treatment Caution And the principle

    For t reatment is that the patient should feel littleAcceptable

    pain.Keep the skin be cool.

    6 . Taboos.3

    a.To avoid using the machine on the abdomen of the pregnant

    women or women in menses

    b.To avoid using the machine on around the parts under which

    metal,p lastic or silicon wee buried.

    c.To avoid usi ng the mac hine on aro und the medical and

    elec tric ins trument,such as the heari ng aid,heart star ter,

    mechanical heart,etc.d.To avoid using the machine on the epileptic and those in

    bad health

    e.To avo id usin g the mac hin e on the wou nd arou ng the

    treatment area and the areas with metals inside of the body.

    f.To avoid using the machine on people who has high blood

    pressure or diabetes or serious skin diseases or heart diseases,

    or who is sens iti ve to el ect ric cur ren t,o r who is reve ivi nghormone treatment.

    Never shot to eyes

    HKS820

    User&Training Manual

    Intense Pulse LightRadioFrequency

  • 8/9/2019 Hng dn s dng thit b trit lng

    15/23

    Radio Frequency Safety Guidelines

    Th e Fo l l owi ng inf or ma t i on is pr ovi de d for th e co rr ect

    ut i l i zat io n of IPL Skin treatm ent system.t he Inf i rmat ion

    includes not only the accid ent p rotec tion regu lati ons t he

    pro duct s com ply wi th ,bu t a ls o the ef f ect ive pre ardi ng

    prop er use of t he product s.

    1)Elect ric safe ty regulat ion

    The EMC Dire ctiv e 89/336/EEC amen ded by 92/3 1/EC &

    9 3 / 6 8 / E E C E N 5 5 0 1 5 : 2 0 0 0 + A 1 + A 2 / L U M2 0 0 7 0 4 0 2 5 /

    EMCEN61000-3-2 :2000+A2/LUM200704025/EMCEN

    61000-3-3:1995+A1+A2/LUM200704025/EMCEN61547:

    1997+A1/LUM200704025/EMC

    2)Mate rial ROHS test2002 /95/EC

    Restric t ion of use o f certain Hazardou s

    Substance in Electr ical&electronics Equipment/ROHS.

    3)Electromagetic radiation safety regulation LVD/EN60601-

    1:2006/AGC10430904GZ05E3EMC/EN60601-1-2:2001+

    A1:2006/AGC10430904GZ05E1

    4)ISO13485:2003 MEDICAL

    14

    HKS820

    User&Training Manual

    Intense Pulse LightRadioFrequency

  • 8/9/2019 Hng dn s dng thit b trit lng

    16/23

    15

    HKS820

    User&Training Manual

    Intense Pulse LightRadioFrequency

    Radio Frequency Safety Guidelines

    What is Radio Frequency?

    RF is used for dermal skin heating with sparing of the epidermis.

    This will result in non-ablative skin tightening and lifting without

    injection and surgery.

    What is the advantage?

    The results are a firmer, refreshed and more youthful face, lifted

    brows and eyel ids, less wrinkles and sharper jaw line again.

    Eyebags and double chin will improve with this treatment too.

    How does it work?

    First, heat generated by RF waves shrinks the bundle of collagen

    under the skin . The collagen becomes shorter and the skin

    tightens. The second phase begins as the body responds. The

    collagen will be gradual ly healed, renewed and even more

    collagen will be produced. The skin tightens and overall look is

    improved.

    What do I expect during the treatment?

    gentle warming sensation is felt throughout the procedures. As

    there is minimal redness after the treatment, normal activity can

    be resumed immediately.

    How many sessions are required?

    1times/2weeks

    5-6 sessions is recommended

    for optimal longer lasting result

    in tre ati ng the wrink les and

    lifting the face.

  • 8/9/2019 Hng dn s dng thit b trit lng

    17/23

    16

    HKS820

    User&Training Manual

    Intense Pulse LightRadioFrequency

    7.RF Operate the Device

    7.1 Operate interface

    1M 3M 10M

  • 8/9/2019 Hng dn s dng thit b trit lng

    18/23

    17

    HKS820

    User&Training Manual

    Intense Pulse LightRadioFrequency

    7.RF Operate the Device

    7.1 Operate interface

    wrinkles onone's forehead

    TreatingPeriorbital Lines

    JowlSkin Lifting

    Pouch

    NeckSkin Lifting

    Small Probe for Face Big Probe for body/neck Tripolar For body/Jowl

  • 8/9/2019 Hng dn s dng thit b trit lng

    19/23

    18

    HKS820

    User&Training Manual

    Intense Pulse LightRadioFrequency

    7.RF Operate the Device

    7.2 Manual Model Treatment

    Choice right Probe as you want and adjust the t imer and

    energy,press OFF be ON,the Device star t to work.

    User need press the switch in handle.

    Timer Adjust,Max is 30Minutes

    Choice small bipolar probe

    1MHz1M

    3M

    10M

    Continuous or discontinuous

    Energy Adjust

    Adjust Button

    Choice big bipolar probe

    3MHz

    Choice tr ipolar probe

    10MHz

  • 8/9/2019 Hng dn s dng thit b trit lng

    20/23

    19

    8.Treatment Procedure

    8.1 .Operate ion techn igue:Let the treatment probe touch

    the target area ad mover(Or Slide)from the inner to the outer

    and round and round and from the lower place to the higher,

    when you do the treatment ont he upper lid,Pls move a bi t

    more quickly,when the gel on the face get drier,please add

    some GEL and go on wi th the treatment .

    8.2.Face(Includeing cheek,eye,forhead,lip,neck)

    Operation procedure(About 50minutes for whole face,15-

    20minutes for neck)

    a.car ry out a skin evaluation before

    treatment.

    B.Clean skin

    c.tone skin

    d.massage wi th GEL

    e.clean skin

    f.smear gel on skin and apply treatment with trobe.

    g.let the probe touch the skin and make treatment

    Course of treatm ent:On e cou rse of t reatments includ es

    5trea tments at an interval of every 10-15days.

    Curative effect

    After one treatment,the heated subcutaneous fiber shrinks

    inst antl y,th eref ore f ins wrin kles are impr oved ,and skin

    becom es ten der,sommth a nd comp act.A fter oneco urse

    of treatment :the col lagen protein is regenerated for long

    term,skin becomes tender and smooth,wrikles are reduced,and skin is tigh tened and compact .

    HKS820

    User&Training Manual

    Intense Pulse LightRadioFrequency

  • 8/9/2019 Hng dn s dng thit b trit lng

    21/23

    HKS820

    User&Training Manual

    Intense Pulse LightRadioFrequency

    20

    8.Treatment Procedure

    8.3.Body(striae gravidarum)Operation procedure(About 60-90minutes for topical area)a.Carry out a skin evaluation before treatment.B.clean skinc.massage with body slimming distilla ted.Smear body slimming diatillate on skin and apply treatment

    with probe.e.clean skinf.let the probe touch the skin and make treatment.Course of treatment:One course of treatments includes 5treatments at a interval of every 10-15days.Curative effect After one treatment,the heated subcutaneousfiber shrinks instantly,therefore skin become smooth,compactand elastic.

    After one course of treatment;Skin becomes compact andflabby skin is improved.

  • 8/9/2019 Hng dn s dng thit b trit lng

    22/23

    21

    9.Treatment Caution

    9.1.for treatment is that the pat ient should feel needling&hot.

    9.2.The treatment head must be kept on the skin (sliding);

    otherwise, the skin will get burned.Before the treatment head

    leaves the skin , you must loose the button on the head or

    loose the foot switch.

    9.3.When the temperature of the t reatment head is over too

    high, you should stop treatment.The energy you adopt should

    not be too h igh; otherwise, the skin will get burned.

    9.4.Please carry out sk in moisturiz ing and sun proof cream

    work after treatments, do not wash faces with hot water (use

    wate r under the body temperatu re), and do not go for hot

    spring and massage.

    10.1.The abdomen of the pregnant women or women in menses

    10.2 .To avoid using the mach ine on around the parts underwhich metal,plast ic or silicon wee buried.

    10.3.To avoid using the machine on the epileptic and those in

    bad health

    10.4.To avoid using the machine on people who has high blood

    pressure or diabetes or serious skin diseases or heart diseases,

    or who is sens iti ve to e lect ric cur ren t,o r who is reve iving

    hormone treatment.

    10.Treatment Taboos

    HKS820

    User&Training Manual

    Intense Pulse LightRadioFrequency

  • 8/9/2019 Hng dn s dng thit b trit lng

    23/23

    11.Treatment Parameter

    Probe

    small

    big

    small

    big

    Tripolar

    big

    bigTripolar

    Tripolar

    Tripolar

    Tripolar

    15-20

    22-28

    14-17

    22-28

    20-26

    22-28

    22-2822-28

    18-24

    22-28

    22-28

    EnergyTherapy Position

    jowl

    neck

    Abdomenbuttocks

    Low-necked

    arm

    leg

    eye side

    forehead

    Mode Timer

    10

    5

    8

    5

    10

    15

    1010

    10

    10

    10

    12.HKS817C RF Device Superiority

    12.1.Whole ABS Plastic Mould.

    12.2.Variable frequencies depending on the chosenTreatment.12.3.Frequency of steady emission.12.4.It does not present any contagious risk.12.5.Maximum security for the client, defaultprograms12.6.Permits to adapt the used power used accordingto the zone and deepness to work.

    We Are Looking for Sale agent over the world.

    HKS820

    User&Training Manual