CONTENTS
1. INTERLEMIND KP roof panels - technical description.................................................................... 2
1.1. Introduction ....................................................................................................................................... 21.2. Roof panel shape................................................................................................................................ 21.3. Roof panels structure.......................................................................................................................... 31.4. Technical data .................................................................................................................................... 31.5. Static capacity.................................................................................................................................... 6
1.6. Fixing elements.................................................................................................................................. 8
-Rafters ....................................................................................................................................... 8-Lengthwise overlapping and joining elements positioning........................................................... 9-Cross-section joining – roof extension ...................................................................................... 10
1.7. Architectural details ......................................................................................................................... 11-Suspended gutter – detail 01..................................................................................................... 11-Middle gutter – detail 02 .......................................................................................................... 12-Lateral attic with built in gutter – detail 03................................................................................ 13-Ridge – detail 04...................................................................................................................... 14-Pent roof ridge – detail 05 ........................................................................................................ 15-Front attic – detail 06 ............................................................................................................... 16
-Front end piece – detail 07........................................................................................................ 17-Roof to wall flashing – detail 08... ............................................................................................ 18-Roof dilatation – detail 09 ........................................................................................................ 19
-Light cupola aperture – detail 10 .............................................................................................. 20- Cap opening for light cupola– detail 11.................................................................................... 21- Pipe passage through the roof – detail 12 ................................................................................. 22
1.8. Instructions for assembly.................................................................................................................. 23
2. INTERLEMIND ZP fa cade (wall) panels - technical description.................................................... 24 2.1. Introduction .................................................................................................................................... 24
2.2. Wall panel shape............................................................................................................................. 242.3. Wall panels structure....................................................................................................................... 262.4. Technical data ................................................................................................................................. 272.5 .Fixing methods ................................................................................................................................ 30
-Longitudinal connection and sort of joint parts......................................................................... 31-Wall panel supporter................................................................................................................ 32
- ZP2 panel attachment ............................................................................................................. 332.6. Static capacity.................................................................................................................................. 342.7. Architectural details ......................................................................................................................... 35
-Base girt - detail 13 ................................................................................................................ 35-Angle ending – exterior –detail 14 ........................................................................................... 36
-Angle ending – interior -.detail 15............................................................................................ 37-Cross connection – facade exterior detail 16............................................................................. 38-Facade contact with clasic wall -detail 17................................................................................. 39-Wall opening – upper and down cap - detail 18 ........................................................................ 40-Wall opening – side lining - detail 19...................................................................................... 41
2.8. Istructions for assembly.................................................................................................................... 42
7/29/2019 katalog-arhitektonskih-detalja
http://slidepdf.com/reader/full/katalog-arhitektonskih-detalja 2/42
2
1.1 INTERLEMIND KP roof panels introduction.
INTERLEMIND KP roof construction system is based on modular roof panels 1000 mmin width, fixed to the roof structure by corresponding fixing elements.
INTERLEMIND KP provides high quality thermal and sound insulation, due to the hard
core of polyurethane foam, applied and expanded between two roll formed sheets in a
continuous process.
In view of modern buildings construction, implying fast assemblage and the use of ready-made elements, INTERLEMIND Thermo-roof has a very wide application. It is applicable
for building of industrial, trade, sport, business and entertainment facilities.
1.2 INTERLEMIND KP roof panel s shape
For F-1 top side of the panel trapezoidal roll formed sheets TR 40/250 are used, and for F-2
side TR 1.5/66.67 .
7/29/2019 katalog-arhitektonskih-detalja
http://slidepdf.com/reader/full/katalog-arhitektonskih-detalja 3/42
3
1.3 INTE RLEMIND KP roof panels structure
Protection PE film
Top coating to RALsh ade
Primer coat
Preliminary treatmen t
Zn coat
Steel substrate
Preliminary treatmen t
Back side protective coat for PUR adhesion
Zn coat
PUR
INTERLEMIND KP consists of the interior and exterior roll formed sheets, pre-coated by
an organic, mostly polyester paint system by the coil coating technology, and a hard core of
polyurethane foam with 38-42 kg/m3 density. The three elements make a compact panel,
70 to 100 mm in thickness, which provides the necessary supporting capacity and sealing.During the production process the panels are protected by strippable polyethylene film to
enable easy manipulation, transportation and fixing, which is subsequently removed.Standard panel lengths: 2,000 to 12,500 mm
Standard sheet thicknesses: 0.5 to 0.7 mm
1.4. INTERLEMIND KP roof panels t echnical data.
-Coating systems and color shades:
Polyester coating 25 ? in thickness for F1 in accordance to EN 10169, in color shades toRAL color card. Other coating systems are subject to special request.
-Thermal insulation:
Thermal conductivity coefficient ?=0.022 (W/mK)
*Sheet thickness 0.6/0.6 mm
Panel Type* Mean heat-transfer coefficient
k(W/m2K)
KP 70/30KP 80/40
KP 90/50
KP 100/60
0.6470.493
0.400
0.336
7/29/2019 katalog-arhitektonskih-detalja
http://slidepdf.com/reader/full/katalog-arhitektonskih-detalja 4/42
4
-Fire resistance: INTERLEMIND KP belongs to Class B (hardly combustible material) toDIN 4102 Part 1.
Coil coated steel strip type INTERLEMIND is a fireproof material(Class A2) to
DIN 4102 Part1.
Hard polyurethane foam without the metal plates is a normally inflammable material (Class
B2) to DIN 4102 Part 1, while in case of use of PIR-insulation, it is classified as a hardly
combustible material (Class B1). Tightness of joint is very important – geometre, sealant,fixings. Fixing of the panels in the furnace has strong influence.
New fire resistance classes in EU 15/20/30/45/60/90.
-Anti -corrosion protection: INTERLEMIND KP panels are produced from cold rolled steel strip, galvanized on both
sides and pre-coated (EN 10142, EN 10143, and EN 10169-1 and 2).
The anti-corrosion protection of polyester coating system is classified as Category III
according to DIN 55928 Part 8.
-Sound insulation:
*sheet thickness 0.6/0.6 mm
-Panel weight (kg/m2):
Panel Type* Rw(dB)
KP 70/30
KP 80/40
KP 90/50KP 100/60
31
32
3232
Weight of Interlemind KP roof panel thickness of 50 mm
Thicknes of outside steel(mm)
0,30 0,35 0,40 0,45 0,50 0,55 0,60 0,65 0,70 0,75 0,80 0,850,30 7,55 8,04 8,53 9,02 9,51 10,00 10,50 10,99 11,48 11,97 12,46 12,95
0,35 7,97 8,46 8,95 9,44 9,93 10,42 10,91 11,40 11,89 12,39 12,88 13,370,40 8,39 8,88 9,37 9,86 10,35 10,84 11,33 11,82 12,31 12,80 13,29 13,78
0,45 8,81 9,30 9,79 10,28 10,77 11,26 11,75 12,24 12,73 13,22 13,71 14,200,50 9,22 9,71 10,21 10,70 11,19 11,68 12,17 12,66 13,15 13,64 14,13 14,62
0,55 9,64 10,13 10,62 11,11 11,60 12,10 12,59 13,08 13,57 14,06 14,55 15,040,60 10,06 10,55 11,04 11,53 12,02 12,51 13,00 13,49 13,98 14,48 14,97 15,46
0,65 10,48 10,97 11,46 11,95 12,44 12,93 13,42 13,91 14,40 14,89 15,38 15,870,70 10,90 11,39 11,88 12,37 12,86 13,35 13,84 14,33 14,82 15,31 15,80 16,29
0,75 11,31 11,80 12,30 12,79 13,28 13,77 14,26 14,75 15,24 15,73 16,22 16,71
0,80 11,73 12,22 12,71 13,20 13,69 14,19 14,68 15,17 15,66 16,15 16,64 17,13
T h i c k n e s s of i n s i d e s t e e l ( m
m )
0,85 12,15 12,64 13,13 13,62 14,11 14,60 15,09 15,58 16,07 16,57 17,06 17,55
7/29/2019 katalog-arhitektonskih-detalja
http://slidepdf.com/reader/full/katalog-arhitektonskih-detalja 5/42
5
-Roof plane inclination:
In normal applications the roof inclination angle is 6o (10.5%). If there are no lengthwise
panel joints between the ridge and the gutter the inclination angle can be 5 o (8.8%), while
with additional sealing of roof panels lengthwise and cross-section joints, the inclination
angle of the roof panels can be reduced to min. 4o (7%).
-Fixing elements:
To assemble INTERLEMIND KP panels only the attested fixing elements can be used.
Self-tapping screws are made of stainless steel with 19 mm dia. washer and EPDM gasket.
For any specific static calculation the fixing method should be set forth.
Fixing elementsSub-structure type
KP 70/30 KP 80/40 KP 90/50 KP 100/60
Steel
Concrete with anchored steel segments6.3 x 110 6.3 x 120 6.3 x130 6.3 x140
Wood 6.5 x 150 6.5 x 160 6.5 x 170 6.5 x 180
Depending on the steel sub-structure thickness the screw type and the hole diameter aredetermined in accordance with the recommendations of the producer.
It is also possible to use self tapping screws, whereby it is not necessary to make anyholes, since they cut a screw thread into the surface at the same time, thus accelerating theassembling process.Blind rivets 4.0?10 with a stainless steel shank are used for joining the flashings and trims
(hole diameter 4.10 mm).
Screw type Sub- structure thickness (mm ) Hole diameter (mm)
2.0 -3.0 5.00
3.0-3.9 4.0-4.9
5.0-5.9
6.0-10.0
10.1-12.0
5.05 5.35
5.65
5.80
5.85
7/29/2019 katalog-arhitektonskih-detalja
http://slidepdf.com/reader/full/katalog-arhitektonskih-detalja 6/42
6
1.5. INTERLEMIND K P roof panels static capacity:
PanelType
Sheetthickness
Unit loadq(kN/m
2)
_____________
? ?
Unit loadq(kN/m
2)
__________________
?? ? ? ( mm) 1. 00 1. 25 1. 50 1. 75 1. 00 1. 25 1. 50 1. 75
0. 5/ 0. 5 2. 90 2. 80 2. 65 2. 35 3. 70 3. 40 3. 15 3. 00
0. 6/ 0. 6 3. 05 2. 90 2. 75 2. 40 3. 90 3. 60 3. 35 3. 2070/ 30
0. 7/ 0. 7 3. 20 3. 00 2. 85 2. 45 4. 10 3. 80 3. 55 3. 400. 5/ 0. 5 3. 40 3. 10 3. 05 2. 85 4. 20 3. 85 3. 55 3. 40
0. 6/ 0. 6 3. 55 3. 20 3. 15 2. 95 4. 40 4. 05 3. 75 3. 6080/ 40
0. 7/ 0. 7 3. 70 3. 30 3. 20 3. 05 4. 60 4. 25 4. 00 3. 800. 5/ 0. 5 3. 80 3. 45 3. 40 3. 15 4. 60 4. 15 4. 00 3. 800. 6/ 0. 6 4. 05 3. 75 3. 50 3. 40 5. 00 4. 45 4. 30 4. 1090/ 50
0. 7/ 0. 7 4. 30 4. 05 3. 60 3. 65 5. 20 4. 75 4. 60 4. 450. 5/ 0. 5 4. 20 3. 80 3. 75 3. 60 5. 20 4. 80 4. 40 4. 200. 6/ 0. 6 4. 40 4. 05 3. 90 3. 75 5. 40 5. 00 4. 60 4. 40100/ 60
0. 7/ 0. 7 4. 60 4. 30 4. 05 3. 90 5. 60 5. 20 4. 80 4. 60
The static capacity calculations to determine the span between the rafters mustconsider the following elements: the building height (<8m, <20m, >20m), the buildingshape, whether the building is closed or opened on one side, as well as roof positions(ridge, edge areas, angles) in accordance with DIN 1055, Sheet 4, 1986, regulating thewind load.
Height above the ground (m)
< 8 m
< 20 m
> 20 m
Building shape h/a <0,25 m >0.50 <0.25 >0.50 <0.25 >0.50
Closed buildings
Wind load (kN/m2) 0.50 0.50 0.80 0.80 1.10 1.10
Wind blow (kN/m2) 0.25 0.35 0.40 0.56 0.55 0.77
Buildings opened on one side
Wind load (kN/m2) 0.75 0.75 1.20 1.20 1.65 1.65
Wind blow (kN/m2) 0.75 0.75 1.20 1.36 1.65 1.85
7/29/2019 katalog-arhitektonskih-detalja
http://slidepdf.com/reader/full/katalog-arhitektonskih-detalja 7/42
7
The choice of the color shade is also important for the static capacity calculation because thedarker shades (shade group III) have a more significant influence on the thermal dilatation of the sheets than the light shades panels (shade group I).
The color shades are classified into three groups (I, II and III), as follows:
Group I RAL 9001, 9002, 9010, 1013, 1015, 7035Group II RAL 1002, 9006, 1024, 2004, 7001, 7002, 5012, 7037
Group III RAL 6010, 3002, 6003, 3009, 5001, 8014
Snow guard brackets:Depending on the roof plane inclination (?), the roof area and the climate zone the number of snow guard brackets is determined and fixed to the rafters through INTERLEMIND KP .
Lightning rod:Since the whole roof acts as a lightning conductor within the lightning conductor installation,only a good connection with the grounding is necessary.
Packing:
For truck transport the package height should be 1100 to 1500 mm, and 10 to 20 panels arestacked, depending on their thickness. The max. package weight is 3 tons.
7/29/2019 katalog-arhitektonskih-detalja
http://slidepdf.com/reader/full/katalog-arhitektonskih-detalja 8/42
8
1.6. INTERLEMIND KP roof panels fi xing methods."INTERLEMIND - THERMO ROOF
TYPE - KP
Roff Panel Support
Intersupport b > 60 mm
Steel construcion Wood construcion
Inconkreter Steel profile 60 / 40 / 3 mm is
bulit or sheet 60 / 8 mm.
Concrete construction
End support a > 40 mm
End steel support Middle Suport
b b
b
a
a a
7/29/2019 katalog-arhitektonskih-detalja
http://slidepdf.com/reader/full/katalog-arhitektonskih-detalja 9/42
9
LONGITUDINAL CONNECTION AND SORT OF JOINT PARTS
F1
F2
Seal tape for joint
Elastic seal tape one side adhesive
Protective seal p ad EPDM
Screw inox with seal ? 19 mm and di ftung EPDM
Screw inox w ith seal ? 19 mm and diftung EPDM
Type of material
5
4
3
2
1
Poz
built in workmenship process
B x D = 20 x 6
A x D = 25 x 50
6,3x19
6,3x1406,3x1306,3x1206,3x110
KP100KP90KP80KP70
1
5
Distance between screws min 300 mm
5
3 2 4
3
" INTERLEMIND" -THERMO ROOF
TYPE - KP
7/29/2019 katalog-arhitektonskih-detalja
http://slidepdf.com/reader/full/katalog-arhitektonskih-detalja 10/42
10
m i n 2 0 0 m m
1
4
42 3
KP
KP with Overlap
Cross connection - Roof Extension
4
5
4
5
KP70 K P80 K P90 KP100
6,3x110 6,3x120 6,3x130 6,3x140
6,3x19
A x D = 25 x 50
B x D = 20 x 10
PE 3 x 15
Poz1
2
3
4
5
Type of materialScrew Inox O19mm
Protective Pad
Lasting Elastic Seal tape one side adhesive
m i n 2 0 0 m
m
" INTERLEMIND" - thermo Roof
Type - KP
m i n 1 0 0 m
m
Screw Inox O19mm
Lasting Elastic Seal tape one side adhesive
7/29/2019 katalog-arhitektonskih-detalja
http://slidepdf.com/reader/full/katalog-arhitektonskih-detalja 11/42
11
1.7. INTERLEMIND KP ROOF PANELS ARCHITECTURAL DETAILS
KP
5
1
8
7
6
9
4
2
3
ZP2
SUSPENDED GUTTER
1
2
3
4
5
6
7
8
9
Poz Type of material KP70 KP80KP90 KP100
Wind batten
Gutter
Support pending gu tter FeZn,5 x25 xL
Preliminary steel sheet for gutter
Screw inox with seal O 19 mm and diftung EPDM
Rivet inox steel
Elastic s ticky blend
Elastic seal tape one side adhesive
Panel lining
011
012
013
014
6,3 x 19
4 x 10
B x D = 30 x 25
B x D = 20 x 10
015
" INTERLEMIND" - THERMO ROOf
TYPE - KP
01
~1/3~2/3
7/29/2019 katalog-arhitektonskih-detalja
http://slidepdf.com/reader/full/katalog-arhitektonskih-detalja 12/42
12
1
2
5
3
4
8
6 7 9
MIDDLE GUTTER
not in standart
B x D = 20 x 10
022
Mineral wool
6,3 x 19
014
011
Heater gutter sistem
Waste pipe
Elastic seal tape one side adhesive
Thermic insulation
Screw inox O 19 mm, diftung EPDM
Preliminary steel sheet for gutter
Wind batten
KP100KP90KP80KP70Type of materialPoz
9
8
7
6
5
4
3
2
1
021
023
Interior gutter
Gutter support , FeZn, 5 x 25 x L
" INTERLEMIND" - THERMO ROOF
TYPE - KP
02
7/29/2019 katalog-arhitektonskih-detalja
http://slidepdf.com/reader/full/katalog-arhitektonskih-detalja 13/42
13
LONGITUDINAL CAP WALL WITH INTERIOR GUTTER
1 0 0
KP
ZP
8
10
1
2 4
7
6
3
5
8
Poz Type of material
1
2
3
4
5
6
7
8
9
10
KP70 KP80 KP90 KP100
Screw ino x with seal O 19 mm and diftung EPDM
Cap wall
Interior lining
Preliminary steel sheet for gutter
Wind batten
Interior gutter
Support for gutt er, FeZn 5 x 25 x L
Gutter mask
Elastic seal tape one side adhesive
Rivet inox steel
031
032
014
011
033
034
035
B x D = 20 x 10
6,3 x 19
4 x 10
" INTERLEMIND" - THERMO ROOF
TYPE - KP
03
99 10
9
7/29/2019 katalog-arhitektonskih-detalja
http://slidepdf.com/reader/full/katalog-arhitektonskih-detalja 14/42
14
3 0
3 0
5 6 81
2
3
4
7
Poz Type of material
1
2
3
4
5
6
7
8
KP70 KP80 KP90 KP100
Ridge
Ridge mask
Ridge separator
Elastic st icky blend
Butilene seal type
Profil filling KP - negative
041
042
043
B x D = 20 x 10
2 x 6
6,3 x 19
044
6,3x110 6,3x120 6,3x130 6,3x140
Screw inox wit h seal O 19 mm and diftung EPDM
Screw inox wit h seal O 19 mm and diftung EPDM
KP
RIDGE
" INTERLEMIND" - THERMO ROOF
TYPE- KP
04
4
76 5
8
7/29/2019 katalog-arhitektonskih-detalja
http://slidepdf.com/reader/full/katalog-arhitektonskih-detalja 15/42
15
7
ZP-2
3 4
81 5 69
KP
RIDGE FOR ONE LEAD ROOF
Poz Type of material1
2
3
4
5
6
7
8
9
KP70 KP80 KP90 KP100
Butilen e seal tape
Ridge for one lead roof
Ridge separator
Interior panel joint lining
Profile filling KP - negative
Rivet inox steel
Thermic insulation
051
043
052
6,3 x 19
4 x 10
mineral wool
2 x 6
6,3x1106,3x120 6,3x130 6,3x140
044
Screw inox wit h seal O 19 mm and diftung EPDM
Screw inox wit h seal O 19 mm and diftung EPDM
"INTERLEMIND"- THERMO ROOFTYPE - KP
05
7
7
2
7/29/2019 katalog-arhitektonskih-detalja
http://slidepdf.com/reader/full/katalog-arhitektonskih-detalja 16/42
16
FRONT ATTIC
Poz Type of material
1
2
3
4
5
6
7
8
KP70 KP80 KP90 KP100
End profile
Interior lining
Cap wall
Cap wall suppor ter FeZn , t = 2mm
Rivet inox steel
061
062
063
6,3 x 19
4 x 10
064
Elastic s eal tape one side adhesive B x D = 20 x 6
B x D = 30 x 25
Screw inox wi th seal O 19 mm and diftung EPDM
Elastic s eal tape one side adhesive
ZP2
m i n 2 0 0
8
5
6
2
3
4
1
67 KP
" INTERLEMIND"-THERMO ROOF
TYPE- KP
06
910
11
5
5
9
10
11
6,3x70 6,3x80 6,3x90 6,3x100
6,3x1406,3x1306,3x1206,3x110
Screw inox wi th seal O 19 mm and diftung EPDM
Screw inox wi th seal O 19 mm and diftung EPDM
Diftung EPDM A x D = 25 x 50
7/29/2019 katalog-arhitektonskih-detalja
http://slidepdf.com/reader/full/katalog-arhitektonskih-detalja 17/42
17
Poz Type of material
1
2
3
4
5
6
7
8
KP70 KP80 KP90 KP100
Front liling
Rivet inox steel
071
B x D = 20 x 6
6,3 x 19
A x D = 25 x 50Cover with EPDM
B x D = 30 x 20
6,3x1106,3x120 6,3x130 6,3x140
6,3x70 6,3x80 6,3x90 6,3x100
4 x 10
FRONT AND PIECE
m i n 6 0
ZP2
8
3
1 4 7 2 5 6
KP
Screw ino x wit h seal O 19 mm and diftung EPDM
07
9 Support of cap 072
9
"INTERLEMIND" - THERMO ROOFTYPE - KP
Elastic s eal tape one side adhesive
Elastic s eal tape one side adhesive
Screw inox with seal O 19 mm and diftung EPDM
Screw inox wit h seal O 19 mm and diftung EPDM
7/29/2019 katalog-arhitektonskih-detalja
http://slidepdf.com/reader/full/katalog-arhitektonskih-detalja 18/42
18
Poz Type of material1
2
3
4
5
6
7
8
9
KP70 KP80 KP90 KP100Wall capping
End cap
Ceal cement
Rivet inox steel
Thermic insolation
081
082
6 x 50
6,3 x 19
4 x 10
mineral wool
sika flex
Screw inox with seal O 19 mm and diftung EPDM
Elastic seal tape one side adhesive B x D = 20 x 6
083
Screw inox wi th plastic diftung
Interior wall lining
7 8
ROOF TO WALL FLASHING
1
2
3
4
5 69
" INTERLEMIND" - THERMO ROOF
TYPE - KP
08
7/29/2019 katalog-arhitektonskih-detalja
http://slidepdf.com/reader/full/katalog-arhitektonskih-detalja 19/42
19
40
ROOF DILATATION
Poz Type of material
1
2
3
4
5
6
7
8
KP70 KP80 KP90 KP100
Strain lining up I
Rivet inox steel
091
092
093
mineral wool
Elastic seal tape one side adhesive B x D = 15 x 3
Screw inox wi th seal O 19 mm and diftun g EPDM 6,3x110 6,3x120 6,3x130 6,3x140
B x D = 20 x 6
4 x 10
Strain lining up II
Strain lining - down
Elastic seal tape one side adhesive
Thermic insulation
5 4 2 5 541 8
7 6
" INTERLEMIND" -THERMO ROOF
TYPE - KP
09
3 76
KP
7/29/2019 katalog-arhitektonskih-detalja
http://slidepdf.com/reader/full/katalog-arhitektonskih-detalja 20/42
20
Poz Type of material
1
2
3
4
5
6
7
8
9
KP70 KP80 KP90 KP100
Cupola lining- head on ridge
Ridge separator
Rivet inox steel
101
102
044
4 x 10
mineral wool
043
Screw inox w ith seal O 19 mm and dift ung EPDM
B x D = 20 x 10
Profile filling KP - negative
6,3x70 6,3x80 6,3x90 6,3x100
B x D = 20 x 6
Cupola lini ng- head on gutter
Elastic s eal tape one side adhesive
Elastic s eal tape one side adhesive
Thermic insulation
CAP FOR LIGHT CUPOLA
m i n 2 0 0
39
7
4
6
5
8
12
KP
d o s l e m
e n a
5 8
"INTERLEMIND" - THERMO ROOF
TYPE- KP
10
14 14?
6
7/29/2019 katalog-arhitektonskih-detalja
http://slidepdf.com/reader/full/katalog-arhitektonskih-detalja 21/42
21
Poz Type of material
10
11
12
13
14
KP70 KP80 KP90 KP100
Cupola lining - side
Cupola supporter
103
A X D = 25 x 50
104
Screw inox with s eal O 19 mm and di ftung EPDM
Support with EPDM diftung
sika flex
6,3x110 6,3x120 6,3x130 6,3x140
Seal c iment
CAP OPENING FOR LIGHT CUPOLA
5
78 9
10
11 12
13
14
6
" INTERLEMIND" - THERMO ROOFTYPE - KP
11
7/29/2019 katalog-arhitektonskih-detalja
http://slidepdf.com/reader/full/katalog-arhitektonskih-detalja 22/42
22
Poz Type of material
1
2
3
4
5
KP70 KP80 KP90 KP100
Diftung EPDM
Inside lining
111
6,3 x 25
sika flex
112
Screw inox with seal O 19 mm and diftun g EPDM
Seal c iment
4 x 10Rivet inox steel
Diftung m ade from flexible black rubber in one side EPDM (ethilene propilene dien monomer)
highly resistant on atmospheric conditions.
EPDM
Diftung
Diameter
[ mm ]High
[ mm ]
Base
[ mm ]Color
N 1
N 2
N 3
N 4
N 5
N 6
black
black
black
black
black
black
do 50
60 - 102
76 - 152
102 - 178
152 - 280
254 - 467
52
84
97
114
115
145
114 x 114
203 x 203
254 x 254
279 x 279
355 x 355
628 x 628
1 2 3
4 5
" INTERLEMIND" - termokrovTIP - KP
12Pipe passage through the roof
7/29/2019 katalog-arhitektonskih-detalja
http://slidepdf.com/reader/full/katalog-arhitektonskih-detalja 23/42
23
1.8. INTERLEMIND KP ROOF PANELS INSTRUCTIONS FOR ASSEMBLY .
FOR HIGH-QUALITY ASSEMBLY OF INTERLEMIND KP ROOF PANELSTHE FOLLOWING INSTRUCTIONS SHOULD BE OBSERVED:
First of all, check the condition of the sub-structure to verify its geometry andevenness;In case of defects, carry out all the necessary corrections;Before fixing, in places of lengthwise or cross-section overlapping, joining or flashing, the strippable protective PE foil should be removed;For panel cutting only circular saws or jig-saws should be used. Do not use a grinder because the grinding wheels produce high temperatures and destroy the anticorrosiveorganic coating; After cutting and hole drilling all metal filings should be immediately removed from
the panel surfaces since they represent an extremely strong corrosion source;In panel assembly, special attention must be paid to the lengthwise overlappingwhere total incumbency is required to achieve complete sealing. In some cases,additional sealing is achieved by injecting silicone putty at panel joints on F2 side,immediately before positioning of each panel.Roofs with inclination less than 6o need additional sealing of the panel joint on theexterior side (F1) by permanently elastic sealing strip.In building with special temperature regime, such as refrigerating plants and the like,the lengthwise overlapping on the inside (F2) should also be additionally sealed bypermanently elastic sealing strip to prevent the diffusion of water vapor in someclimate conditions and the condensate formation on the interior joint.
During panels unloading and vertical transportation, only one package should behandled at a time. Fork lifters can be used to transport panel packages up to 6000 mmin length. Wire-cables are not allowed for panel packages transport by crane; instead,conveyor belts of corresponding capacity should be used.
7/29/2019 katalog-arhitektonskih-detalja
http://slidepdf.com/reader/full/katalog-arhitektonskih-detalja 24/42
24
INTERLEMIND ZP FACADE (WALL) PANELS - TECHNICAL DESCRIPTION
2.1. INTERLEMIND ZP Facade (Wall) Panels introductionINTERLEMIND ZP vertical facade construction system is based on modular wall panels1000 mm in width, fixed to the sub-construction by corresponding binding elements.INTERLEMIND ZP provides high quality thermal and sound insulation, due to the self-extinguishing and environment friendly hard polyurethane foam core, applied andexpanded between two roll formed sheets in a continuous process.Depending on the lengthwise joint shape, INTERLEMIND ZP is available in two
versions: ZP-1 with concealed joint and ZP-2 with visible joint.
2.2. INTERLEMIND ZP facade panel shape
ZP-1
7/29/2019 katalog-arhitektonskih-detalja
http://slidepdf.com/reader/full/katalog-arhitektonskih-detalja 25/42
25
ZP-2
For exterior panels, F1 and F2 trapezoidal roll formed sheets TR 1.5/66.67 are used,and for the interior side 0.8/20 low profile sheets are used.
7/29/2019 katalog-arhitektonskih-detalja
http://slidepdf.com/reader/full/katalog-arhitektonskih-detalja 26/42
26
2.3. INTERL EMIND ZP facade wall panels structure.
Protection PEfilm
Top coating to RAL shade
Primer coat
Preliminary treatment
Zn coat
Steel substrate
Preliminary treatment
Back side protective coat for PUR adhesion
Zn coat
PUR
INTERLEMIND ZP consists of the interior and exterior roll formed sheets, pre-coated by
an organic, mostly polyester paint system by the coil coating technology, and a hard coreof polyurethane foam with 38-42 kg/m3 density. The three elements make a compactpanel, 30 to 180 mm in thickness, which provides the necessary supporting capacity andsealing, as well as thermal and sound insulation.During the production process the panels are protected by strippable polyethylene film toenable easy manipulation, transportation and fixing, which is subsequently removed.
Standard panel lengths: 2,000 to 12,500 mmStandard sheet thicknesses: 0.30 to 0.70 mm
7/29/2019 katalog-arhitektonskih-detalja
http://slidepdf.com/reader/full/katalog-arhitektonskih-detalja 27/42
27
2.4. INTERL EMIND ZP facade wall panels technical data.
- Coating systems and color shades:
Polyester coating 25 ? in thickness for F1 in accordance to EN 10169, in colors toRAL color card. Other coating systems are subject to special request.- Thermal insulation:
Thermal conductivity coefficient ?=0.022 (W/mK)
Heat-transfer coefficient k (W/m2K)
*The numeric value next to the panel type represents the outside panel thickness (s)
- Fire resistance:INTERLEMIND KP belongs to Class B (hardly combustible material) toDIN 4102 Part1.Coil coated steel strip type INTERLEMIND is a fireproof material(Class A2) toDIN 4102 Part1.Hard polyurethane foam without the metal plates is a normally inflammable material(Class B2) to DIN 4102 Part 1, while in case of use of PIR-insulation, it is classified as ahardly combustible material (Class B1). Tightness of joint is very important – geometre,sealant, fixings. Fixing of the panels in the furnace has strong influence. New fire
resistance classes in EU 15/20/30/45/60/90.
- Anti-corrosion protection:
INTERLEMIND ZP panels are produced from cold rolled steel strip, galvanized on bothsides and pre-coated (EN 10142, EN 10143, and EN 10169 -1 and 2).The anti-corrosion protection of polyester coating system is classified as Category IIIaccording to DIN 55928 Part 8.
Sheet thicknessPanelType
* 0.30/0.30 0.40/0.40 0.50/0.50 0.60/0.60
ZP 30ZP 50ZP 60ZP 80
0,6950,4260,3570,269
0,6700,4280,3580,270
0,7040,4290,3590,271
0,7090,4310,3610,271
7/29/2019 katalog-arhitektonskih-detalja
http://slidepdf.com/reader/full/katalog-arhitektonskih-detalja 28/42
28
- Sound insulation:
Sound reduction coefficient, Rw(dB)
Sheet thickness mm
Panel type * 0.30/0.30 0.40/0.40 0.50/0.50 0.60/0.60 ZP 30ZP 50 ZP 60 ZP 80
2627 28 29
2829 30 30
3031 31 32
31 32 32 33
*The numeric value next to the panel type represents the outside panel thickness (s)
Panel weight (kg/m2)
Panel weight (kg/m2)
ZP 1 – 50 mm wall panel thickness
Thickness of outside steel sheet (mm)
0,30 0,35 0,40 0,45 0,50 0,55 0,60 0,65 0,70 0,75 0,80 0,85
0,30 7,02 7,43 7,85 8,27 8,69 9,11 9,52 9,94 10,36 10,78 11,20 11,61
0,35 7,43 7,85 8,27 8,69 9,11 9,52 9,94 10,36 10,78 11,20 11,61 12,03
0,40 7,85 8,27 8,69 9,11 9,52 9,94 10,36 10,78 11,20 11,61 12,03 12,45
0,45 8,27 8,69 9,11 9,52 9,94 10,36 10,78 11,20 11,61 12,03 12,45 12,87
0,50
8,69
9,11
9,52
9,94
10,36
10,78 11,20
11,61
12,03
12,45
12,87
13,29
0,55
9,11
9,52
9,94
10,36
10,78
11,20 11,61
12,03
12,45
12,87
13,29
13,70
0,60
9,52
9,94
10,36
10,78
11,20
11,61 12,03
12,45
12,87
13,29
13,70
14,12
0,65
9,94
10,36
10,78
11,20
11,61
12,03 12,45
12,87
13,29
13,70
14,12
14,54
0,70
10,36
10,78
11,20
11,61
12,03
12,45
12,87
13,29
13,70
14,12
14,54
14,96
0,75
10,78
11,20
11,61
12,03
12,45
12,87
13,29
13,70
14,12
14,54
14,96
15,38
0,80
11,20
11,61
12,03
12,45
12,87
13,29
13,70
14,12
14,54
14,96
15,38
15,79 T h i c k n e s s
o f
i n s i d e s t e e l s h e e t ( m m )
0,85
11,61
12,03
12,45
12,87
13,29
13,70
14,12
14,54
14,96
15,38
15,79
16,21
7/29/2019 katalog-arhitektonskih-detalja
http://slidepdf.com/reader/full/katalog-arhitektonskih-detalja 29/42
29
Panel weight (kg/m2)
ZP 2 – 50 mm wall panel thi ckness
Thickness of ou tside steel sheet (mm)
0,30
0,35
0,40
0,45
0,50
0,55
0,60
0,65
0,70
0,75
0,80
0,85
0,30
7,25
7,67
8,09
8,51
8,92
9,34
9,76
10,18
10,60
11,01
11,43
11,85
0,35 7,71 8,13 8,54 8,96 9,38 9,80 10,22 10,64 11,05 11,47 11,89 12,31 0,40
8,17
8,58
9,00
9,42
9,84
10,26
10,67
11,09
11,51
11,93
12,35
12,76
0,45
8,62
9,04
9,46
9,88
10,30
10,71
11,13
11,55
11,97
12,39
12,80
13,22
0,50
9,08
9,50
9,92
10,33
10,75
11,17
11,59
12,01
12,42
12,84
13,26
13,68
0,55
9,54
9,96
10,37
10,79
11,21
11,63
12,05
12,46
12,88
13,30
13,72
14,14
0,60
10,00
10,41
10,83
11,25
11,67
12,09
12,50
12,92
13,34
13,76
14,18
14,59
0,65
10,45
10,87
11,29
11,71
12,12
12,54
12,96
13,38
13,80
14,21
14,63
15,05
0,70
10,91
11,33
11,75
12,16
12,58
13,00
13,42
13,84
14,25
14,67
15,09
15,51
0,75
11,37
11,79
12,20
12,62
13,04
13,46
13,88
14,29
14,71
15,13
15,55
15,97
0,80
11,82
12,24
12,66
13,08
13,50
13,91
14,33
14,75
15,17
15,59
16,00
16,42
T h
i c k n e s s o f i n s i d e s t e e l s h e e t ( m m
)
0,85
12,28
12,70
13,12
13,54
13,95
14,37
14,79
15,21
15,63
16,04
16,46
16,88
-Fixing elements:
To assemble INTERLEMIND ZP panels only the attested fixing elements can be used.Self-tapping screws are made of stainless steel with 19 mm dia. washer and EPDM
gasket.For any specific static calculation the fixing method should be set forth.
Fixing elementsSub-structure type
ZP 30*
ZP 50*
ZP 60*
ZP 80*
SteelConcrete with anchored steel segments
6,3x60 6,3x80 6,3x90 6,3x115
Wood 6,0x90 6,0x110 6,0x120 6,5x150* Applies to both ZP-1 and ZP-2.
7/29/2019 katalog-arhitektonskih-detalja
http://slidepdf.com/reader/full/katalog-arhitektonskih-detalja 30/42
30
Depending on the steel sub-structure thickness the screw type and the hole diameter aredetermined in accordance with the recommendations of the producer.
It is also possible to use self tapping screws, whereby it is not necessary to make anyholes, since they cut a screw thread into the surface at the same time, thus accelerating the
assembling process.Blind rivets 4.0?10 with a stainless steel shank are used for joining the flashings and trims(hole diameter 4.10 mm).
2.5 Fixing methods
RP
SP
RP
RP
SP
Screw type Sub- structure thickness (mm ) Hole diameter (mm)
2.0 -3.0 5.00
3.0-3.9 4.0-4.9 5.0-5.9 6.0-10.0 10.1-12.0
5.05 5.35 5.65 5.80 5.85
7/29/2019 katalog-arhitektonskih-detalja
http://slidepdf.com/reader/full/katalog-arhitektonskih-detalja 31/42
31
Having in mind the applicable regulations, in order to determine the fixing method of INTERLEMIND ZP panels, it is necessary to have in view the following factors:Wind load capacityHeight of the building above the groundType of the building: closed or open on one sidePosition of the panel in the facade wall (central or edge area)Number of supporting joists where the panels will be fixed (two or more)Thermal load depending on the panel color shade (Group I, II or III)
It is very important to point out that the panels at the corner studs should always be fixed inthe standard way – through the panel, and the visible fixing elements should be masked byflashing elements, which means that the concealed joint used with ZP-2 is not permissible inthis case.
2.6. INTERL EMIND ZP facade wall panels static capacity:
Nominalthickness
Sheetthickness
Unit load
q ( kN / m2) _____________
? ?
Unit load
q ( kN / m2) __________________
? ? ?
S( m ) ( m ) 1. 00 1. 25 1. 50 1. 75 1. 00 1. 25 1. 50 1. 750. 3/ 0. 3 2. 20 2. 00 1. 90 1. 75 2. 90 2. 70 2. 55 2. 350. 4/ 0. 4 2. 40 2. 20 2. 10 1. 80 3. 20 3. 00 2. 80 2. 65
0. 5/ 0. 5 2. 60 2. 40 2. 25 2. 00 3. 45 3. 20 3. 00 2. 8530
0. 6/ 0. 6 2. 75 2. 55 2. 40 2. 15 3. 65 3. 40 3. 20 3. 050. 3/ 0. 3 3. 10 2. 90 2. 70 2. 25 4. 05 3. 60 3. 30 3. 05
0. 4/ 0. 4 3. 40 3. 15 2. 95 2. 55 4. 55 4. 20 3. 80 3. 550. 5/ 0. 5 3. 65 3. 40 3. 20 2. 80 4. 90 4. 55 4. 25 3. 95
50
0. 6/ 0. 6 3. 90 3. 60 3. 40 3. 05 5. 20 4. 80 4. 55 4. 300. 3/ 0. 3 3. 50 3. 20 3. 05 3. 20 4. 45 3. 95 3. 65 3. 35
0. 4/ 0. 4 3. 85 3. 55 3. 35 2. 90 5. 15 4. 60 4. 20 3. 850. 5/ 0. 5 4. 15 3. 85 3. 60 3. 20 5. 55 5. 10 4. 65 4. 35
60
0. 6/ 0. 6 4. 40 4. 10 3. 85 3. 45 5. 85 5. 60 5. 15 4. 750. 3/ 0. 3 4. 25 3. 95 3. 70 3. 65 5. 15 4. 60 4. 20 3. 90
0. 4/ 0. 4 4. 65 4. 05 4. 05 3. 85 5. 95 5. 30 4. 85 4. 500. 5/ 0. 5 5. 00 4. 35 4. 35 4. 15 6. 65 5. 95 5. 40 5. 00
80
0. 6/ 0. 6 5. 30 4. 65 4. 65 4. 40 7. 15 6. 50 5. 90 5. 50
7/29/2019 katalog-arhitektonskih-detalja
http://slidepdf.com/reader/full/katalog-arhitektonskih-detalja 32/42
32
" INTERLEMIND -THERMO WALL
TYPE - ZP
FACADE PANEL SUPPORTER
MIDDLE SUPPORTER b > 60 mm
STEEL CONSTRUCTION WOOD CONSTRUCTION
CONCRETE CONSTRUCTION
END SUPPORTER - UP a > 40 mm
a
END SUPPORTER - DOWN
b
b
a
a
b
7/29/2019 katalog-arhitektonskih-detalja
http://slidepdf.com/reader/full/katalog-arhitektonskih-detalja 33/42
33
" INTERLEMIND" - THERMO WALLTYPE - ZP
Longitudinal connection and sort of joint parts
Poz Type of material
1
2
3
4
Screw inox
180
ZP2
Joint pad L [ mm ]
Pipe distancer L [ mm ]
30 50 60 80
32 42 62-
6,3 x 50 6,3 x 70 6,3 x 806,3 x 105
6,3 x 60 6,3 x 80 6,3 x 906,3 x 115Screw inox with seal O 19 mm and diftung EPDM
ZP1
ZP1
Attachm ent ZP1 do it at si de of end o f tw o panel s
1 23 4 4
a) b)
Attachment ZP2 a) middle area b) end supporting
7/29/2019 katalog-arhitektonskih-detalja
http://slidepdf.com/reader/full/katalog-arhitektonskih-detalja 34/42
34
Poz Type of material
1
2
3
50
6,3 x 70
L = 180
Screw inox wi th seal O 19 mm and diftun g EPDM
Joint pad
60 80
ZP2
6,3 x 80 6,3x105
32 42 62Pipe distancer
ZP2 PANEL ATTECHMENT
1
2
3
m
i n 6 0 m m
ZP2
ZP2
" INTERLEMIND" - THERMO WALLTYPE - ZP -2
12
1 8 0
7/29/2019 katalog-arhitektonskih-detalja
http://slidepdf.com/reader/full/katalog-arhitektonskih-detalja 35/42
35
2.7. INTERL EMIND ZP facade wall panels architectural details
Poz Type of material
1
2
3
Base cap of panel
B x D = 20 x 10
BASE GIRT
B x D =40 x 20
ZP1 ZP2
131 132
Elastic seal tape one side adhesive
Elastic seal tape one side adhesive
ZP
2
3
1
" INTERLEMIND" - THERMO WALL
TYPE - ZP
13
7/29/2019 katalog-arhitektonskih-detalja
http://slidepdf.com/reader/full/katalog-arhitektonskih-detalja 36/42
36
Poz Type of material
1
2
3
4
5
Ang le li nin g - exter ior
Elastic seal tape one side adhesive
142
4 x 10
B x D = 50 x 20
Lining supporter
Rivet inox st eel
ANGLE ENDING - EXTERIOR
ZP1 ZP2
141
B x D = 50 x 20Elastic seal tape one side adhesive
ZP
5
1 2 4 3
3
4
2
ZP
"INTERLEMIND" - THERMO WALLTYPE - ZP
14
7/29/2019 katalog-arhitektonskih-detalja
http://slidepdf.com/reader/full/katalog-arhitektonskih-detalja 37/42
37
Poz Type o f material
1
2
3 B x D = 50 x 20
Angle lining -inter ior
Elastic seal tape one sid e adhesive
ZP1
151
4 x 10Rivet inox steel
ANGLE ENDING - INTERIOR
ZP2
ZP
2
1
2 ZP
3
" INTERLEMIND" -THERMO WALL
TYPE - ZP
15
7/29/2019 katalog-arhitektonskih-detalja
http://slidepdf.com/reader/full/katalog-arhitektonskih-detalja 38/42
38
Poz Type of material
1
2
3 B x D = 20 x 10
Cross connection cap
Elastic seal tape one side adhesive ( EPDM )
ZP1
161
4 x 10Rivet inox steel
CROSS CONNECTION - FACADE EXTERIOR
ZP2
B x D = 40 x 20Elastic seal tape one side adhesive (EPDM)4
ZP
4
3
ZP
1
2
"INTERLEMIND" -THERMO WALL
TYPE - ZP
16
7/29/2019 katalog-arhitektonskih-detalja
http://slidepdf.com/reader/full/katalog-arhitektonskih-detalja 39/42
39
Poz Type of material
1
2
3
4
5
Wall lining - exterior
Elastic seal tape one side adhesive
172
4 x 10
B x D = 20 x 10
Rivet inox steel
FACADE CONTACT FOR CLASIC WALL
ZP1 ZP2
171
S48 x 32Speike anker
6 mineral wool
Wall lining - int erior
Thermic insulation
3
1
5
6
4
3
2
" INTERLEMIND" - THERMO WALL
TYPE - ZP
17
7/29/2019 katalog-arhitektonskih-detalja
http://slidepdf.com/reader/full/katalog-arhitektonskih-detalja 40/42
40
Poz Type of material
1
2
3
4
5
Upper cap
Elastic seal tape one side adhesive (EPDM)
182
4 x 10
B x D = 20 x 10
Rivet inox steel
WALL OPENING- UPPER AND DOWN CAP
ZP1 ZP2
181
B x D = 40 x 20
Down cap
Elastic seal tape one side adhesive (EPDM)
"INTERLEMIND" -THERMO WALLTYPE - ZP
1
34
2
5
18
7/29/2019 katalog-arhitektonskih-detalja
http://slidepdf.com/reader/full/katalog-arhitektonskih-detalja 41/42
41
Poz Type of material
1
2
3
4
5
Side lining cap for opening
Elastic seal tape one side adhesive (EPDM)
6,3 x 25
WALL OPENING - SIDE LINING
ZP1 ZP2
191
B x D = 20 x 10
Screw inox with s eal
4 x 10
B x D = 40 x 20
Rivet inox steel
Elastic seal tape one side adhesive (EPDM)
ZP21
4 3 5
ZP
F1
F2
" INTERLEMIND" - THERMO WALL
TYPE - ZP
19
7/29/2019 katalog-arhitektonskih-detalja
http://slidepdf.com/reader/full/katalog-arhitektonskih-detalja 42/42
INSTRUCTIONS FOR ASSEMBLY
FOR HIGH-QUALITY ASSEMBLY OF INTERLEMIND ZP WALL PANELS THEFOLLOWING INSTRUCTIONS SHOULD BE OBSERVED:
Before all, check the condit ion of the foundation sole and the entire construction to veri fytheir geometry and evenness;
In case of defects, carry out all the necessary corrections;
Take exact measurements of the facade tie beams in order to determine the panelsarrangement and the corner ends, and then fit in the base flashing;
Before fixing remove the strippable protective foil from the inside panel surface (F-2) andfrom the outside surface (F-1) remove only those parts that will be covered by the overlappingparts and from corner ends;
Apply the adhesive sealing strips in positions specified by the installation plan;
If need be, provide the supporting elements during the assembling of the wall panels;
The panels are to be fitted so that the lower end is 8-10 mm away from the base flashing. Tofacilitate the fitting, wooden slats can be inserted, which are later removed.Using a long spirit level, position the wall panels to precise vertical and fix with screws. For
good quality fitting the lower panel edges must form a straight line.When fixing the panels special attention must be paid to avoid the outer sheet deformation (F-1) at the joint due to inadequate torsion force, which would provoke permanent deformations
and poor esthetics. Therefore, screwdrivers with limited torque should be used;
When fitting wall panels of different lengths, the longer panels should be fitted first, and thenthe shorter ones, because that way it would be easier to achieve the required vertical line atpanel joints;
For panel cutti ng only circular saws or jig-saws should be used. Do not use a grinder because
the grinding wheels produce high temperatures and destroy the anticorrosive organic coating;
After cutting and hole dril ling all metal fil ings should be immediately removed fromhorizontal surfaces on the walls (base fl ashings, window fl ashings, etc.) since they representextremely strong corrosion sources;
During panels unloading and vertical transportation, only one package should be handled at atime. Fork lifters can be used to transport panel packages up to 6000 mm in length. Wire-cables are not allowed for panel packages transport by crane; instead, conveyor belts of corresponding capacit y should be used.
?