51
LC700/800 BATTERYLESS TELEPHONE

LC 700/800 BATTERYLESS TELEPHONE - 青岛东方拓普海洋工程有限公司-MRC ... · 2013-07-29 · (QAS-ADD-008/1/10.10.13) manual\telephone\SPT_eng.doc (MRC MARINE RADIO CO.,

  • Upload
    vucong

  • View
    230

  • Download
    0

Embed Size (px)

Citation preview

LC‐700/800 BATTERYLESS TELEPHONE

MARINE RADIO CO.,LTD. 주/선박무선

Subject : Sound Power Telephone Page : (1 / 10)

Date : 2010.12.23 Doc. : SBT_eng.doc

(QAS-ADD-008/1/10.10.13) manual\telephone\SPT_eng.doc (

MARINE RADIO CO., LTD.) MRC

DRAWING FOR APPROVAL

Messrs. ----------------------------------------------

(LC-800 Series Sound Power Telephone)

Revision History

01 : Issued for first design : SPT manual

02 :

03 :

This document contains proprietary information and may not be copied, reproduced, or utilized in anyway, in all or in part without

written permission from Marine Radio Co., Ltd.

Copyright © 2010 Marine Radio Co., Ltd. All rights reserved.

MARINE RADIO CO.,LTD. 주/선박무선

Subject : Sound Power Telephone Page : (2 / 10)

Date : 2010.12.23 Doc. : SBT_eng.doc

(QAS-ADD-008/1/10.10.13) manual\telephone\SPT_eng.doc (

MARINE RADIO CO., LTD.) MRC

Preface

Thank you for buying the MRC model Sound Power Telephone system. To ensure that your equipment provides optimum satisfaction and service, please read this manual carefully before attempting to operate the LC-800 Series. We recommend that you store the manual carefully for future reference.

Important

On the Sound Power Telephone system, we use inboard communication at strategic position (W / H, Engine Control Room and Steering Gear Room). If we are not handled correctly, could present danger to yourself or others property, These warnings and notes are classified as described below. Please be fully aware of the importance of these items when using this manual.

Cautions indicate items that, if ignored, may result in personal injury or physical damage.

Notes on using the LC-800 series

1. Do not dismantle the system. : Failure to observe these cautions may result in electric shock or damage to the in-external equipment. Please contact to your authorized MRC dealer for maintenance, inspections, and adjustments.

2. Regular check: Must be need a regular check of operator at least once a semiannually and maker or guaranteed engineer for safety using of the system.

3. Observe the instruction in this manual for correct operation of the PA system. 4. To prevent moisture and foreign materials entering your system, do not place objects on your one. 5. Do not place objects that could obstruct the airflow through the cooling vents in front, on top, or to the

sides of the system.

MARINE RADIO CO.,LTD. 주/선박무선

Subject : Sound Power Telephone Page : (3 / 10)

Date : 2010.12.23 Doc. : SBT_eng.doc

(QAS-ADD-008/1/10.10.13) manual\telephone\SPT_eng.doc (

MARINE RADIO CO., LTD.) MRC

Contents

--- Introduction --- 1. General Descriptions ............................................................................................................................. 4

2. Operations and Specifications ............................................................................................................... 4 2.1 Telephone Sets ............................................................................................................................... 4 2.2 Electric Specifications ..................................................................................................................... 5 2.3 Direct Type Telephone .................................................................................................................... 5

2.3.1 Calling ...................................................................................................................................... 5 2.3.2 Answering ................................................................................................................................ 5

2.4 Mutual Selection Type (Max. 1:12 Station)-(LC-800 Series Only) .................................................. 5 2.4.1 Calling ...................................................................................................................................... 5 2.4.2 Answering ................................................................................................................................ 5

2.5 Cautions of system ......................................................................................................................... 6

3. Sound Power Telephone Equipment Family .......................................................................................... 6 3.1 Desk Type Telephone (LC-711, LC-812) ........................................................................................ 6 3.2 Wall Type Telephone (LC-713, LC-814) ......................................................................................... 7 3.3 Flush Type Telephone (LC-715, LC-816) ......................................................................................... 7 3.4 Portable Type Telephone (LC-717, LC-818) ................................................................................... 8

5. Maintenance and Trouble Shooting ....................................................................................................... 9 5.1 Maintenance for CBT ...................................................................................................................... 9

6. Inspection Data Sheet ......................................................................................................................... 10

MARINE RADIO CO.,LTD. 주/선박무선

Subject : Sound Power Telephone Page : (4 / 10)

Date : 2010.12.23 Doc. : SBT_eng.doc

(QAS-ADD-008/1/10.10.13) manual\telephone\SPT_eng.doc (

MARINE RADIO CO., LTD.) MRC

1. General Descriptions The telephone system is designed for high stability, amplification and clearance. To gain the functions of the existing system and excellent communication quality, it implements the low power consumption using a capacitor-battery. Also, it is operated independently of the power supply of the vessel so it is used in emergency. The LC-800 system described in this manual consists of the direct (1:1) and mutual selection types (1:12 / 24).

2. Operations and Specifications

2.1 Telephone Sets: The sound power (battery less) telephone consists of the direct and mutual selection types and is divided into the following according to the purpose.

No. Type Name 1:1 1:12 1:24 Area Remark

1 Desk

LC-711 O

Office, Accommodation Room or All Cabin LC-812A O

LC-822A O

2 Wall

LC-713C O Galley, Mess Room(Gland : 2EA)

LC-713F O E/R, S/G Room(W/Sub-Rx, Gland : 2EA)

LC-713G O E/R, S/G Room(W/Headset, Gland : 2EA)

LC-814A O Mess Room(N.W.T)

LC-814B O Galley, Mess Room(Gland : 1EA)

LC-814C O Galley, Mess Room(Gland : 2EA)

LC-814E O Fire Control Station(W/Signal Kit, Gland : 3EA)

LC-814F O E/R, S/G Rm(W/Sub-Rx, Gland : 2EA)

LC-814F1 O E/R, S/G Rm(W/Sub-Rx, Sig Kit, Gland : 2EA)

LC-814G O E/R, S/G Room(W/Headset, Gland : 2EA)

LC-814G1 O E/R, S/G Room(W/Headset, Sig Kit, Gland : 3EA)

LC-824A O Mess Room(N.W.T)

LC-824B O Galley, Mess Room(Gland : 1EA)

LC-824C O Galley, Mess Room(Gland : 2EA)

LC-824E O Fire Control Station(W/Signal Kit, Gland : 3EA)

LC-824F O E/R, S/G Room(W/Sub-Rx, Gland : 2EA)

LC-824F1 O E/R, S/G Room(W/Sub-Rx, Sig Kit, Gland : 2EA)

LC-824G O E/R, S/G Room(W/Headset, Gland : 2EA)

LC-824G1 O E/R, S/G Room(W/Headset, Sig Kit, Gland : 3EA)

3 Flush

LC-715C O W/H or E.C.C/C.C.C

LC-816A O W/H (W/Dimmer Sw.)

LC-816C O Engine Control Room(W/Signal Kit)

LC-826A O W/H (W/Dimmer Sw.)

LC-826C O Engine Control Room(W/Signal Kit)

4 Portable

LC-717 O Bunker Station, Upper Deck P/S

LC-818 O Bunker Station, Upper Deck P/S

LC-828 O Bunker Station, Upper Deck P/S

MARINE RADIO CO.,LTD. 주/선박무선

Subject : Sound Power Telephone Page : (5 / 10)

Date : 2010.12.23 Doc. : SBT_eng.doc

(QAS-ADD-008/1/10.10.13) manual\telephone\SPT_eng.doc (

MARINE RADIO CO., LTD.) MRC

2.2 Electric Specifications a. Compass Safety Distance : Min. 1-meter b. Voice Transmitting Sensitivity : 0.2V ± 0.1Vrms c. Frequency Characteristics: less than 6dB(300Hz ∼ 3kHz) d. Generator Output Voltage : 75V ± 10% e. DC power can be connected to this telephone for dimmer source only.

2.3 Direct Type (1:1 Station)-(LC-700 Series Only)

2.3.1 Calling

a) Lift the handset and quickly rotate the handle of the magnetic generator 10 times. b) Then, the calling signal is transmitted to the called party. c) If the other party responses, you talk with him or her.

2.3.2 Answering

a) The bell rings while the lamp blinks. b) Lift the handset. c) Communication

2.4 Mutual Selection Type (Max. 1:12 Station)-(LC-800 Series Only)

2.4.1 Calling

a) Lift the handset and select the switch you want to call. b) Quickly rotate the handle of the magnetic generator 10 times and then the calling signal is

transmitted to the called party. c) Communication

2.4.2 Answering

a) Same as item 2.3.2

MARINE RADIO CO.,LTD. 주/선박무선

Subject : Sound Power Telephone Page : (6 / 10)

Date : 2010.12.23 Doc. : SBT_eng.doc

(QAS-ADD-008/1/10.10.13) manual\telephone\SPT_eng.doc (

MARINE RADIO CO., LTD.) MRC

2.5 Cautions 2.5.1 This battery-less telephone (sound power telephone) uses the power charged in capacitor for

approximately 30 minutes. 2.5.2 Terminal Board "SN”: Connect to self number. 2.5.3 Terminal Board "COM”: Common line of all telephones 2.5.4 Terminal Board "+, -”: If the relay box is not used, the bell, R/L and horn connected to the external

power (AC/DC). 2.5.5 Terminal Board "B1, B2”: Contact for external signal

3. Sound Power (Battery Less) Telephone Equipment Family 3.1 Desk Type Telephone (LC-711, LC-812)

With a non-waterproofing "ABS" resin, this telephone has speaking circuit, bell, lamp and handset. It is fixed with fastener or bracket so it cannot be separated while the vessel is moved. The terminal box (JB-61, 62) is designed with non-waterproof.

① Case Housing ⑥ Rotary Switch(LC-812) ② Handset ⑦ Telephone Cord ③ Handset Cord ⑧ Fastener ④ Lamp(LED) ⑨ Foot ⑤ Generator Call Handle

MARINE RADIO CO.,LTD. 주/선박무선

Subject : Sound Power Telephone Page : (7 / 10)

Date : 2010.12.23 Doc. : SBT_eng.doc

(QAS-ADD-008/1/10.10.13) manual\telephone\SPT_eng.doc (

MARINE RADIO CO., LTD.) MRC

3.2 Wall Type Telephone (LC-713, LC-814) This telephone includes headset type, sub receiver type and standard type (LC-213F1/G1) that has the

relay circuit for external signal. Also, it is designed to be the indoor waterproof with built-in speaking circuit and LED lamp. In a noisy place, use the headset type (LC-213G/G1) or sub receiver type (LC-213F/F1).

(a) Standard Type (b) Sub-receiver Type (c) Head-set Type

3.3 Flush Type Telephone (LC-715, LC-816) This telephone is designed to be non-waterproof with the built-in handset, speaking circuit, LED lamp,

buzzer and terminal. The LC-816A telephone is a flush type with a dimmer and used in a wheel house.

(a) Dimmer Type (b) Standard Type

1. Bell: Call Bell Signal 2. Handset 3. Handset Cord 4. Lamp (LED): Recognition of Call Bell Signal 5. Magnetic Generator Call Handle 6. Rotary Switch: Selection of Desired Party 7. Dimmer Switch: for Wheel House (24V DC) 8. Panel 9. Terminal

MARINE RADIO CO.,LTD. 주/선박무선

Subject : Sound Power Telephone Page : (8 / 10)

Date : 2010.12.23 Doc. : SBT_eng.doc

(QAS-ADD-008/1/10.10.13) manual\telephone\SPT_eng.doc (

MARINE RADIO CO., LTD.) MRC

3.4 Portable Type Telephone (LC-717, LC-818) This telephone is designed to be indoor waterproof with the built-in handset, speaking circuit, magnetic

generator handle, LED lamp and terminal for cord connection. The auxiliary equipment includes the water-proof junction box (JB-5) and connection cord (5-20m). Generally, in case of calling to the desired place, connect the extension cord and use a handset. The operating method is similar to other telephones. After calling, put the handset in place and close the cover, identifying cable. For storage, disconnect

the connection cable and cover the water-proof cap tightly. For rainy weather, especially, be sure to close the cover to protect the internal device. In rainy weather, especially, be sure to close the cover to protect the internal device.

(a) Portable Type

MARINE RADIO CO.,LTD. 주/선박무선

Subject : Sound Power Telephone Page : (9 / 10)

Date : 2010.12.23 Doc. : SBT_eng.doc

(QAS-ADD-008/1/10.10.13) manual\telephone\SPT_eng.doc (

MARINE RADIO CO., LTD.) MRC

4. Maintenance and Trouble Shooting 4.1 Maintenance

If you use this system properly, it does not generate the system failure. However, if this system generates the failure or error, perform troubleshooting as follows. This manual does not mention the incorrect wiring, missing wiring, insufficient insulation and power

supplier. *Caution: If the failure occurs in relay due to bad contact, you must not clean the contact.

Cause Suspected Point Check Troubleshooting

Impossible calling

Broken magnetic generator coil Check broken line of coil with a tester. Replace it with new

one.

Bad contact of magnetic generator Check the contact with a multi-meter Clean the contact.

Insufficient output of magnetic generator

Check a voltage with a multi-meter (AC 50V or more)

Replace it with new one.

Bad selection switch Check the contact with a multi-meter Replace it with new one or clean it.

Broken circuit Check broken line according to the schematic diagram

Solder it or replace it with new one.

Bad buzzer or LED

Bad buzzer or contact of buzzer

Check the buzzer or the contact of the buzzer with a multi-meter

Replace it with new one or clean the contact.

Bad LED or contact of LED

Check the LED or the contact of LED with a multi-meter

Replace it with new one or clean the contact.

Broken circuit Check broken line according to the schematic diagram

Solder it or replace it with new one.

Bad calling

Bad calling unit Check the click sound with a Multi-meter.

Replace it with new one.

Bad contact of transmitter microphone units

Separate the end tip of each unit or the handset.

Clean the contact or insert the end tip after testing.

Bad handset cord Check the cord with a tester. Replace it with new one.

MARINE RADIO CO.,LTD. 주/선박무선

Subject : Sound Power Telephone Page : (10 / 10)

Date : 2010.12.23 Doc. : SBT_eng.doc

(QAS-ADD-008/1/10.10.13) manual\telephone\SPT_eng.doc (

MARINE RADIO CO., LTD.) MRC

선박무선

SHOP TEST RECORD of Sound Power Telephone (무전원 전화장치)

Customer(고 객) Ship No.(선 번) - Serial No.(제조번호)

Type(형식) Test Date 200 . .

Place(검사장소) MRC Shop Room Temp.

Test Record of Sound Power Telephone INSPECTION

ITEM INSPECTION METHOD STANDARD LEVEL

MEASURE LEVEL RESULT REMARK

1. Insulating Resistor

Measure of insulation resistor between case and power input line by multi-tester.

more than 10MΩ

2. Transmitting Sensitivity

Measure of loss of voice signal loss on connected phones(1kHz, 10mV)

0.2V ± 0.1 RMS

3. Transmitting Distortion

Measure of distortion in No. 2 state less than -30dB

4. Generator Output Voltage

Measure of output voltage in generator as 5-times turning

75V ± 10%

5. Aging Test Measure of charged voltage in generator as 10-times turning

more than 5-Miniutes

5. Exterior View Test

Confirm an external wound of painting on case. (Color Name : )

Testing by the naked eye

Confirm an fixing holes and dimension.

Compare with Drawing

1. Requirement(요구조건) -1. DNV Rule Pt.4 Vh.9 Sec.4B & DNV Standard For Cert’ 2.4(JAN,2006) -2. IEC60945 -3. IMO RES A.830(19) / 694(17) -4. MRC Standard Requirements(include Manual)

2. The Necessary Equipment 1. Audio Signal Generator : AG-202A 2. Distortion Analyzer : SVM-135A 3. Insulation Tester : E17 4. Oscilloscope : OS-9060D 5. Frequency Counter : TR-5142G

3. Result -1. MRC Standard Shop Trial(제작자 표준 시험) ------------------------------

Tested(시험) Checked(검토) Approved(승인) Witnessed Witnessed Witnessed

Maker Maker Maker YARD CLASS OWNER

LC‐700 BATTERYLESS TELEPHONE

LC‐800 BATTERYLESS TELEPHONE(MAX:12 STATION)

LC‐800 BATTERYLESS TELEPHONE(MAX:18STATION)