40
Series PCW PC Wiring System e-con type is newly added! One-touch connection reduces wiring labor. e-con type is newly added! One-touch connection reduces wiring labor. Branch unit offers commonality Branch unit separates each manufacturer’s 32 point Input/Output (I/O) into 16 point common pin layout. Conversion to a common pin layout, allows connection of the pin to SMC manifold solenoid valves and other manufacturers’ relay terminals without restriction. Power can be supplied to the PLC I/O unit. Compatible branch units are available for each PLC manufacturer’s I/O. Simple parallel wiring type Without time delay unlike serial transmission. Easy visual understanding at a glance, offering simple start-up, de-bug and trouble shooting maintenance. Improved wiring efficiency and ease of operation Dedicated cable reduces wiring-equivalent to a serial transmission system. One-touch type connector offers standardized wiring to prevent incorrect connection and vastly improved operational efficiency. 583 A

PC Wiring System - SMC株式会社ca01.smcworld.com/catalog/BEST-old-en/pdf/ex-pcw.pdfSeries PCW PC Wiring System e-con type is newly added!One-touch connection reduces wiring labor

Embed Size (px)

Citation preview

Page 1: PC Wiring System - SMC株式会社ca01.smcworld.com/catalog/BEST-old-en/pdf/ex-pcw.pdfSeries PCW PC Wiring System e-con type is newly added!One-touch connection reduces wiring labor

Series PCW

PC Wiring System

e-con type is newly added!

One-touch connection

reduces wiring labor.e-con type is newly added!

One-touch connection

reduces wiring labor.

Branch unit offers commonality� Branch unit separates each manufacturer’s 32

point Input/Output (I/O) into 16 point common pin layout.

� Conversion to a common pin layout, allows connection of the pin to SMC manifold solenoid valves and other manufacturers’ relay terminals without restriction.

� Power can be supplied to the PLC I/O unit.� Compatible branch units are available for each

PLC manufacturer’s I/O.

Simple parallel wiring type� Without time delay unlike serial transmission.� Easy visual understanding at a glance, offering

simple start-up, de-bug and trouble shooting maintenance.

Improved wiring efficiency and ease of operation� Dedicated cable reduces wiring-equivalent to a

serial transmission system. � One-touch type connector offers standardized

wiring to prevent incorrect connection and vastly improved operational efficiency.

583 A

Page 2: PC Wiring System - SMC株式会社ca01.smcworld.com/catalog/BEST-old-en/pdf/ex-pcw.pdfSeries PCW PC Wiring System e-con type is newly added!One-touch connection reduces wiring labor

e-con16 point branch unit(with cover)

e-con8 point unit(with cover)

e-con e-con

e-con8 point unit(circuit board)

32 point unit withterminal block

Direct connected branch unit

Note) Applicable e-con type PLC manufacturers: OMRON Corporation, Mitsubishi Electric Corporation

A revolutionary new wiring system...

24 VDCPowersupply

CompatiblePLC Manufacturers

OMRON CorporationMitsubishi Electric CorporationSharp CorporationKEYENCE CORPORATION

32inputs

32inputs

64outputs

584A

Page 3: PC Wiring System - SMC株式会社ca01.smcworld.com/catalog/BEST-old-en/pdf/ex-pcw.pdfSeries PCW PC Wiring System e-con type is newly added!One-touch connection reduces wiring labor

PC Wiring System

Series PCW

8 point unit with terminal block

Branch unit

The PC wiring system simplifies wiring between a PLC and all types of connected equipment.

585 A

Page 4: PC Wiring System - SMC株式会社ca01.smcworld.com/catalog/BEST-old-en/pdf/ex-pcw.pdfSeries PCW PC Wiring System e-con type is newly added!One-touch connection reduces wiring labor

q Insert the electric cables into the cover.w Press with pliers.

(Green): Normal

(Red): Reverse connection

(Off): Unconnected

PLC input/output

Branch 16 point unit

16 point unit

PLC input/output

Branch unit

16 point unit 16 point unit

Input

Input/output

Output

Reverse connection detection functionVisual indication of incorrect wiring of power supply terminal block and power supply status is provided.

Each unit available with cover compatible with DIN rail mounting or as circuit board.

Elimination of branch unitThe function of a branch unit is built-in a 16 point unit, allowing reduction of the number of units.

Common unit can be used.Reduced spare parts enabling easier stock control.

With cover(DIN rail mount compatible) Circuit board type

Series PCW e-con specification Conventional Series PCW

2-color LED indication

Power supplyterminal block

+ -2F2E2D2C2B2A1F1E1D1C1B1A 2928272625242322212019181716151413121110

+ - + - + - + - + - + - + - + - + - + - + - + - + - + - + -

+ + - - 2F 2E 2D 2C 2B 2A- - 1F 1E 1D 1C 1B 1A

29 28 27 26 25 24 23 22 21 20

19 18 17 16 15 14 13 12 11 10+ +

+ + - - 2F 2E 2D 2C 2B 2A

- - 1F 1E 1D 1C 1B 1A

29 28 27 26 25 24 23 22 21 20

19 18 17 16 15 14 13 12 11 10+ +

+

+

-

-2F

2E

2D

2C

2B

2A

-

-1F

1E

1D

1C

1B

1A

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

+

+

+

+

-

-2F

2E

2D

2C

2B

2A

-

-1F

1E

1D

1C

1B

1A

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

+

+

PC wiring 32 point terminal block unitTerminal block layout

General purpose terminal block unitTerminal block layout

General purpose terminal block unitTerminal block layout

Company B’s PLC I/O cardConnector pin assignment (pin layout)

Company A’s PLC I/O cardConnector pin assignment (pin layout) Change of

PLC manufacturers (Company A to Company B)

Terminal block layoutrequires alteration.

Poor performance in maintenance.Wiring must be redesigned again.

PC Wiring system brings common layout.

Standardized pin layoutOnce 32 point terminal block unit or branch unit is replaced, no further wiring/design is necessary.

Adoption of e-con type eliminates the need for special tools and wire stripping.

Input device (sensor)/ output device (solenoid valve, etc.) to be connected.

10 seconds for 4 cables.

10 seconds for 4 cables.

[Promoted or evaluated by]Mitsubishi Electric Corporation, OMRON Corporation, Fuji Electric Co., Ltd.,

Keyence Corporation, SUNX, Anywire Corporation, NKE, Kuroda Precision Industries Ltd., 3M, AMP, SMC

586A

Page 5: PC Wiring System - SMC株式会社ca01.smcworld.com/catalog/BEST-old-en/pdf/ex-pcw.pdfSeries PCW PC Wiring System e-con type is newly added!One-touch connection reduces wiring labor

Branch unit: PLC direct connected typeDirectly mounted on PLC I/O card.

Branch unitConnected to PLC I/O card via connec-tion cable.

8 point branch unitSeparates two of 8 point I/O transmis-sions once those are separated from two of 16 point I/O by the branch unit.

32 point I/O unitWired to PLC I/O card via connection cable and wires connecting equipment to the terminal blocks.

32 point output reduced common unitWired to PLC I/O card via connection cable and wires connecting equipment to the terminal blocks. Products with cross-over common wires are available.

16 point output reduced common unitWires two of 16 point I/O signals once separated by the branch unit to each connecting equipment via terminal block. Products with cross-over com-mon wires are available.

16 point I/O unitWires two of 16 point I/O signals once separated by the branch unit to each connecting equipment via terminal block.DIN rail mount type and box mount types are available.

16 point branch I/O unitUnit with e-con combines branch unit with 16 point unit.

16 point I/O unit16 point unit with e-con allows common models used for both I/O units.

8 point I/O unit8 point unit with e-con allows common models used for both I/O units.Can use two 8 point I/O units in a cas-cade connection.

Series PCW-EC PC Wiring /Series PCW-EC (e-con Type)

Series PCWPC Wiring System /Series PCW

Circuit board type

With cover(DIN rail mount)

Circuit board type

With cover(DIN rail mount)

Circuit board type With cover

(DIN rail mount)

P.589 P.590 P.591

P.595 P.596 P.598

P.597

P.593 P.594 P.599

587 A

Page 6: PC Wiring System - SMC株式会社ca01.smcworld.com/catalog/BEST-old-en/pdf/ex-pcw.pdfSeries PCW PC Wiring System e-con type is newly added!One-touch connection reduces wiring labor

q Insert the electric cables into the cover.

e-con connectorNo need for special tools and wire stripping.

w Press with pliers.10 seconds for 4 cables.

Common Specifications

Weight

Option (e-con Connector)

Series PCW-ECPC Wiring Systeme-con Type

24 VDC

2 A

0.3 A

5 MΩ or more at 100 VDC

500 VAC

500 m/s2

0.4 to 0.6 Nm/0.4 to 0.7 Nm

7 mm

AWG26 to 14 (0.13 to 2.5 mm2)

Conforms to MIL-C-83503

e-con

–25 to 75°C

Rated voltage

Rated current

Insulation resistance

Withstand voltage

Impact resistance

Terminal block specifications

Input/outputconnector

Ambient temperature

Power supply line

Communication line

Screw tightening torque (Phillips head screwdriver/flat head screwdriver)

Wire stripping length (recommended)

Connecting wire size

CS0, CS1

CN0 to CNF

Model

PCW-EC16ZBM00PCW-EC16XBR00PCW-EC16YBR00PCW-EC16ZBM01PCW-EC16XBR01PCW-EC16YBR01PCW-EC16Z00PCW-EC16Z01PCW-EC08Z00PCW-EC08Z01

Weight (g)

47

87

38

78

31

58

1 pc.

ZS-28-CZS-28-C-1ZS-28-C-2

Model

10 pcs./pack

ZS-28-C-PZS-28-C-1PZS-28-C-2P

AWG No.Cross section of

conductor

AWG26 to 24 0.14 to 0.2 mm2

Finished O.D.

ø0.8 to ø1.0

ø1.0 to ø1.2

ø1.2 to ø1.6

Covercolor

Red

Yellow

Orange

Note) Applicability varies dependant on conductive construction, conductive material, and/or insulating material even resulting in inapplicable. Consult with SMC and manufacturer of connecting equipment.

588A

Page 7: PC Wiring System - SMC株式会社ca01.smcworld.com/catalog/BEST-old-en/pdf/ex-pcw.pdfSeries PCW PC Wiring System e-con type is newly added!One-touch connection reduces wiring labor

DC24VMADE INJAPAN

+

-

0 12 3 4 5 6 7 8 9 A B C D E F 1

34

+*S2-S1

2

YMX-F4

CSO

CS1IN

(28.5) 3

44

1304 4

42

DC24VMADE INJAPAN

+

-

0 12 3 4 5 6 7 8 9 A B C D E F 1

34

+*S2-S1

2

YMX-F4

CSO

CS1IN

(48.5)(50)13310.5 10.5

5.1

4528

.3 16.7

4.1

5 5

4.5

4-ø3.2 circuit board mounting hole

Series PCW-EC16 Point Input/Output Branch Unit

Circuit board type

With cover (DIN rail mount compatible)

Circuit board type

With cover (DIN rail mount compatible)

Dimensions

Input

PCW-EC16XBR00PCW-EC16XBR01

PCW-EC16ZBM00PCW-EC16ZBM01

Output Note

PCW-EC16YBR00PCW-EC16YBR01

Circuit board type

With cover (DIN rail mount compatible)

Circuit board type

With cover (DIN rail mount compatible)

Models

∗ Refer to pages 589-1 and 589-2 about the circuit diagram.

589 A

Page 8: PC Wiring System - SMC株式会社ca01.smcworld.com/catalog/BEST-old-en/pdf/ex-pcw.pdfSeries PCW PC Wiring System e-con type is newly added!One-touch connection reduces wiring labor

PCW-EC16YBR00PCW-EC16YBR01 [Applicable PLC example: OMRON Corporation C200H-OD219]

Circuit Diagram

PCW-EC16XBR00PCW-EC16XBR01 [Applicable PLC example: OMRON Corporation C200H-ID218]

Consult with SMC for the manufacturers and models other than shown as the applicable PLC examples.Refer to page 603-1 for details such as pin number or layout.

108109110111112113114115 100101102103104105106107

1514131211109876543210

19

20

17

18

1513

14 16

119

10 12

7

8

53

64

1

2

115114113112111110109108107106105104103102101100

4038

3937

36

35

32

31

3028

2927

26

25

2422

2321 33

342018

1917

16

15

1412

1311

108

97

6

5

42

31

S1

*S2

4

3

2

1

INPUT

0 VDC

(S2)

24 VDC

FEDCBA9876543210

1234

CN0

1234

CN1

1234

CN2

1234

CN3

1234

CN4

1234

CN5

1234

CN6

1234

CN7

1234

CN8

1234

CN9

1234

CNA

1234

CNB

1234

CNC

1234

CND

1234

CNE4321

CNF

Input connector

Output connector

Input/output connector (CS0)

Input/output connector (CS0)

Green Red

Power supplyterminal block

Power supplyterminal block

Input/output connector (CS1)

Input/output connector (CS1)

108109110111112113114115 100101102103104105106107

1514131211109876543210

19

20

17

18

1513

14 16

119

10 12

7

8

53

64

1

2

115114113112111110109108107106105104103102101100

4038

3937

36

35

32

31

3028

2927

26

25

2422

2321 33

342018

1917

16

15

1412

1311

108

97

6

5

42

31

S1

*S2

4

3

2

1

OUTPUT

0 VDC

(S2)

24 VDC

FEDCBA9876543210

1234

CN0

1234

CN1

1234

CN2

1234

CN3

1234

CN4

1234

CN5

1234

CN6

1234

CN7

1234

CN8

1234

CN9

1234

CNA

1234

CNB

1234

CNC

1234

CND

1234

CNE4321

CNF

Green Red

589-1

Series PCW-EC

A

Page 9: PC Wiring System - SMC株式会社ca01.smcworld.com/catalog/BEST-old-en/pdf/ex-pcw.pdfSeries PCW PC Wiring System e-con type is newly added!One-touch connection reduces wiring labor

Circuit Diagram

PCW-EC16ZBM00PCW-EC16ZBM01 [Applicable PLC example: Mitsubishi Electric Corporation A1SX41, A1SY42]

Consult with SMC for the manufacturers and models other than shown as the applicable PLC examples.Refer to page 603-1 for details such as pin number or layout.

Input/output connector

Input/outputconnector (CS0)

Power supplyterminal block

Input/outputconnector (CS1)

CNF4321

CNE4321

CND4321

CNC4321

CNB4321

CNA4321

CN94321

CN84321

CN74321

CN64321

CN54321

CN44321

CN34321

CN24321

CN14321

4321

CN0

S1

*S2

4

3

2

1

INPUT/OUTPUT

0 VDC

(S2)

24 VDC

3937353331292725232119171513119

8642 40383634323028262422201816141210

3 751

191715131197531

2018161412108642

0123456789ABCDEF

FEDCBA9876543210

Green Red

589-2

Series PCW-ECPC Wiring Systeme-con Type

A

Page 10: PC Wiring System - SMC株式会社ca01.smcworld.com/catalog/BEST-old-en/pdf/ex-pcw.pdfSeries PCW PC Wiring System e-con type is newly added!One-touch connection reduces wiring labor

PCW-EC16Z00

DC24V MADE IN JAPAN

+

-

0 1 2 3 4 5 6 7 8 9 A B C D E F 1

34

+*S2-S1

2

YMX-F4

44

1304 4

42

(28.5) 3

PCW-EC16Z01

DC24V MADE IN JAPAN

+

-

0 1 2 3 4 5 6 7 8 9 A B C D E F 1

34

+*S2-S1

2

YMX-F4

(48.5)(50)13310.5 10.5

5.1

4528

.3 16.7

4.1

5 5

4.5

Series PCW-EC16 Point Input/Output Unit

Circuit board type

With cover (DIN rail mount compatible)

Circuit board type

With cover (DIN rail mount compatible)

PCW-EC16Z00PCW-EC16Z01

Circuit board type

With cover (DIN rail mount compatible)

∗ Refer to the figure below for the circuit diagram.

Models

Dimensions4-ø3.2 circuit board mounting hole

PCW-EC16Z00PCW-EC16Z01

Circuit Diagram

CNF4321

CNE4321

CND4321

CNC4321

CNB4321

CNA4321

CN94321

CN84321

CN74321

CN64321

CN54321

CN44321

CN34321

CN24321

CN14321

4321

CN0

01234567191715131197531

2018161412108642

S1

*S2

4

3

2

1

INPUT/OUTPUT

0 VDC

(S2)

24 VDC

FEDCBA

F E D C B A 9 8

9876543210

Input/output connector

Input/output connector (CS0)

Green Red

Power supplyterminal block

590A

Page 11: PC Wiring System - SMC株式会社ca01.smcworld.com/catalog/BEST-old-en/pdf/ex-pcw.pdfSeries PCW PC Wiring System e-con type is newly added!One-touch connection reduces wiring labor

+

-

4 5 6 7 1

34

+*S2-S1

2

YMX-F40 1 2 3

DC24VMADE

INJAPAN

CS0

CS1

(28.5) 3

424

4

8044

+

-

4 5 6 7 1

34

+*S2-S1

2

YMX-F40 1 2 3

DC24VMADE

INJAPAN

CS0

CS1

55

4.5

5.1

4.1

16.7

28.3

45

8310.5 10.5 (50)(48.5)

Series PCW-EC8 Point Input/Output Unit

Circuit board type

With cover (DIN rail mount compatible)

Circuit board type

With cover (DIN rail mount compatible)

PCW-EC08Z00PCW-EC08Z01

Circuit board type

With cover (DIN rail mount compatible)

∗ Refer to the figure below for the circuit diagram.

Models

Dimensions

PCW-EC08Z00PCW-EC08Z01

Circuit Diagram

4-ø3.2 circuit board mounting hole

234

CN5

1 1 1 1 1

*S2

S143

12

INPUT/OUTPUT0VDC

24VDC(S2)

3 3

CN04

CN14

2 2

Input/output connector

234

34

CN2 CN3

234

CN4

21 1 1

CS1

XY0 to XY7

CN7

34

CN6

234

2

CS0

XY8 to XYF

CS0 CS1

Connection

2

Green Red

131 3 5 7 9 11 1915 17

14

13

14842 6

1 3 5 7

10 12

9 11

4 6 8 10 12

19

2016 18

15 17

2016 18Power supplyterminal block

Input/output connector (CS0)

Input/output connector (CS1)

591 A

Page 12: PC Wiring System - SMC株式会社ca01.smcworld.com/catalog/BEST-old-en/pdf/ex-pcw.pdfSeries PCW PC Wiring System e-con type is newly added!One-touch connection reduces wiring labor

Brown

Blue

PVC sheath

Flat cable

AWG28

Power lines

AWG20 (20, 40 cores)

PC Wiring System

Series PCW

Model

Flat cable

Length

Power lines

Sheath O.D.

With power lines

AWG28 (7 wires/0.127 mm)

AWG20 (21 wires/0.18 mm)

PCW-9930661H

10.3 mm

100 m roll

PCW-9903491H

12.0 mm 8.7 mm 11.8 mm

20 cores 40 cores 20 cores 34 cores 40 cores

13.0 mm

Without power lines

Note) The flat ribbon cable without power lines are not available from SMC.If required, please source locally from your preferred supplier.

Cable Specifications

24 VDC

2 A

0.3 A

5 MΩ or more at 100 VDC

0.5 kV

500 m/s2

0.4 to 0.6 Nm/0.4 to 0.7 Nm

0.5 to 0.6 Nm/0.5 to 0.7 Nm

7 mm

AWG26 to 14 (0.13 to 2.5 mm2)

AWG26 to 12 (0.13 to 4 mm2)

Common Specifications

Rated voltage

Rated current

Insulation resistance

Withstand voltage

Impact resistance

Power supply line

Communication lineT

erm

inal

blo

ck

Screwtighteningtorque

Wire strippinglength(recommended)

Connecting wire size

Power terminal (Phillips screwdriver/Flat head screw driver)I/O terminal (Phillips screw driver/Flat head screw driver)

Power terminal

Power terminal

I/O terminal

I/O terminal

592A

Page 13: PC Wiring System - SMC株式会社ca01.smcworld.com/catalog/BEST-old-en/pdf/ex-pcw.pdfSeries PCW PC Wiring System e-con type is newly added!One-touch connection reduces wiring labor

Series PCWBranch Unit: PLC Direct Connected Type

18.2

(5.2)

16.5

70.1

23.1

27.4

Weight

Ambient temperature

25 g

–25 to 55°C

PLC connection

Can be directly mounted on PLC.

PLC

Two pieces are required for 64 points of input/output.Note 1) Combine one piece each of PCW-993106 and PCW-993108 (the PLC connection side connectors are

reversed).Note 2) Combine one piece each of PCW-993107 and PCW-993109 (the PLC connection side connectors are

reversed).

Input

PCW-993104PCW-993106 Note 1)

Output Circuit diagram

PCW-993105PCW-993107 Note 2)

Page 593-1

Page 593-2

Note) Since the PCW series specifications are included in the common specifications, also refer to the common specifications on page 592.

Specifications

Dimensions

Models

CautionWhen removing a cable with connector, a PCW-04T puller is required.

593 A

Page 14: PC Wiring System - SMC株式会社ca01.smcworld.com/catalog/BEST-old-en/pdf/ex-pcw.pdfSeries PCW PC Wiring System e-con type is newly added!One-touch connection reduces wiring labor

A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 A17 A18 A19 A20

B20B19B18B17B16B15B14B13B12B11B10B9B8B7B6B5B4B3B2B1

10

18

20

28

19

11

1A

12

1B

13

1C

14

1D

15

1E

16

1F

17

21

29

22

2A

23

2B

24

2C

25

2D

26

2E

27

2F

11

12

12

3

134

14

5

156

16

7

178

18

9

1910

20

1C

14

1B

13

1A

12

1F

17

19

11

1E

16

18

10

1D

15

20

1019

9

18

817

7

16

615

5

14

413

3

12

21

11

2C

24

2B

23

2A 2F

22 27

29 2E

21 26

28 2D

20 25

A1 A2 A3 A4 A5 A6 A7 A8 A9 A10 A11 A12 A13 A14 A15 A16 A17 A18 A19 A20

B20B19B18B17B16B15B14B13B12B11B10B9B8B7B6B5B4B3B2B1

10

18

20

28

19

11

1A

12

1B

13

1C

14

1D

15

1E

16

1F

17

21

29

22

2A

23

2B

24

2C

25

2D

26

2E

27

2F

11

12

12

3

134

14

5

156

16

7

178

18

9

1910

20

1C

14

1B

13

1A

12

1F

17

19

11

1E

16

18

10

1D

15

20

1019

9

18

817

7

16

615

5

14

413

3

12

21

11

2C

24

2B

23

2A 2F

22 27

29 2E

21 26

28 2D

20 25

Series PCW

Circuit Diagram

PCW-993104 [Applicable PLC example: OMRON Corporation C200H-ID218]

Consult with SMC for the manufacturers and models other than shown as the applicable PLC examples.Refer to page 603-1 for details such as pin number or layout.

PCW-993105 [Applicable PLC example: OMRON Corporation C200H-OD219]

Input/output connector (CN0)

Input/output connector (CN2)Input/output connector (CN1)

Input/output connector (CN2)Input/output connector (CN1)

Input/output connector (CN0)

Power supplyterminal block

Power supplyterminal block

593-1A

Page 15: PC Wiring System - SMC株式会社ca01.smcworld.com/catalog/BEST-old-en/pdf/ex-pcw.pdfSeries PCW PC Wiring System e-con type is newly added!One-touch connection reduces wiring labor

PCW-993107 [Applicable PLC example: Mitsubishi Electric Corporation A1SY42]

PCW-993106 [Applicable PLC example: Mitsubishi Electric Corporation A1SX42]

Consult with SMC for the manufacturers and models other than shown as the applicable PLC examples.Refer to page 603-1 for details such as pin number or layout.

Input/output connector (CN0)Power supplyterminal block

A1A2A3A4A5A6A7A8A9A10A11A12A13A14A15A16A17A18A19A20

B20 B19 B18 B17 B16 B15 B14 B13 B12 B11 B10 B9 B8 B7 B6 B5 B4 B3 B2 B1

10

18

20

28

19

11

1A

12

1B

13

1C

14

1D

15

1E

16

1F

17

21

29

22

2A

23

2B

24

2C

25

2D

26

2E

27

2F

11

12

12

3

134

14

5

156

16

7

178

18

9

1910

20

1C

14

1B

13

1A

12

1F

17

19

11

1E

16

18

10

1D

15

20

1019

9

18

817

7

16

615

5

14

413

3

12

21

11

2C

24

2B

23

2A 2F

22 27

29 2E

21 26

28 2D

20 25

Input/output connector (CN1) Input/output connector (CN2)

Input/output connector (CN1) Input/output connector (CN2)

Input/output connector (CN0)

2520

2D28

2621

2E29

2722

2F2A

23

2B

24

2C

11

12

12

3

134

14

5

156

16

7

178

18

9

1910

20

15

1D

10

18

16

1E

11

19

17

1F

12

1A

13

1B

14

1C

20

1019

9

18

817

7

16

615

5

14

413

3

12

21

11

2F

27

2E

26

2D

25

2C

24

2B

23

2A

22

29

21

17

1F

16

1E

15

1D

14

1C

13

1B

12

1A

11

19

28

20

18

10

B1B2B3B4B5B6B7B8B9B10B11B12B13B14B15B16B17B18B19B20

A20 A19 A18 A17 A16 A15 A14 A13 A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 A1

Power supplyterminal block

Circuit Diagram

593-2

PC Wiring System Series PCW

A

Page 16: PC Wiring System - SMC株式会社ca01.smcworld.com/catalog/BEST-old-en/pdf/ex-pcw.pdfSeries PCW PC Wiring System e-con type is newly added!One-touch connection reduces wiring labor

Series PCWBranch Unit: DIN Rail Mount Type

Weight

Ambient temperature

80 g

–25 to 80°C

28.3

45103

16.7

(3.6)

4.1

5.1

10.5 10.5

OUT

RS-

4950.5

4.5

55

Two pieces are required for 64 points of input/output.

Input

PCW-993023APCW-993015APCW-993139A

Output Circuit diagram

PCW-993033APCW-993017APCW-993140A

Page 594-1

Page 594-2

Page 594-3

PLC connection

Connected to PLC via connection cable.

PLC

∗ Refer to page 601 for the junction cable part number.

Note) Since the PCW series specifications are included in the common specifications, also refer to the common specifications on page 592.

Specifications

Dimensions

Models

594A

Page 17: PC Wiring System - SMC株式会社ca01.smcworld.com/catalog/BEST-old-en/pdf/ex-pcw.pdfSeries PCW PC Wiring System e-con type is newly added!One-touch connection reduces wiring labor

PCW-993033A [Applicable PLC example: OMRON Corporation C200H-OD218]

2F

27

2E

26

2D

25

2C

24

2B

23

2A

22

29

21

17

1F

16

1E

15

1D

14

1C

13

1B

12

1A

11

19

28

20

18

10

2F

27 26

2E

25

2D

24

2C

23

2B

22

2A

21

29

20

2818

10

19

11

1A

12

1B

13

1C

14

1D

15

1E

1617

1F

2

1 3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

2020

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40

1

2

39373533312927252321191715131197531

Input/output connector (CN1) Input/output connector (CN2)

Input/output connector (CN0)

2F

27

2E

26

2D

25

2C

24

2B

23

2A

22

29

21

17

1F

16

1E

15

1D

14

1C

13

1B

12

1A

11

19

28

20

18

10

2F

27 26

2E

25

2D

24

2C

23

2B

22

2A

21

29

20

2818

10

19

11

1A

12

1B

13

1C

14

1D

15

1E

1617

1F

2

1 3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

2020

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40

1

2

39373533312927252321191715131197531

Input/output connector (CN1) Input/output connector (CN2)

Power supplyterminal block

Power supplyterminal block

Power supplyterminal block

Circuit Diagram

PCW-993023A [Applicable PLC example: OMRON Corporation C200H-ID219]

Consult with SMC for the manufacturers and models other than shown as the applicable PLC examples.Refer to page 603-1 for details such as pin number or layout.

Input/output connector (CN0)Power supplyterminal block

Power supplyterminal block

594-1

PC Wiring System Series PCW

A

Page 18: PC Wiring System - SMC株式会社ca01.smcworld.com/catalog/BEST-old-en/pdf/ex-pcw.pdfSeries PCW PC Wiring System e-con type is newly added!One-touch connection reduces wiring labor

PCW-993017A [Applicable PLC example: Mitsubishi Electric Corporation A1SY42]

2F

27

2E

26

2D

25

2C

24

2B

23

2A

22

29

21

17

1F

16

1E

15

1D

14

1C

13

1B

12

1A

11

19

28

20

18

10

2F

27 26

2E

25

2D

24

2C

23

2B

22

2A

21

29

20

2818

10

19

11

1A

12

1B

13

1C

14

1D

15

1E

1617

1F

2

1 3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

2020

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

246810121416182022242628303234363840

1

2

39 37 35 33 31 29 27 25 23 21 19 17 15 13 11 9 7 5 3 1

Input/output connector (CN1) Input/output connector (CN2)

Input/output connector (CN2)Input/output connector (CN1)

Input/output connector (CN0)

13579111315171921232527293133353739

2

1

40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20 20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

31

2

1F

17 16

1E

15

1D

14

1C

13

1B

12

1A

11

19

10

18 28

20

29

21

2A

22

2B

23

2C

24

2D

25

2E

2627

2F

10

18

20

28

19

11

1A

12

1B

13

1C

14

1D

15

1E

16

1F

17

21

29

22

2A

23

2B

24

2C

25

2D

26

2E

27

2F

Power supplyterminal block

Power supplyterminal block

PCW-993015A [Applicable PLC example: Mitsubishi Electric Corporation A1SX42]

Circuit DiagramConsult with SMC for the manufacturers and models other than shown as the applicable PLC examples.Refer to page 603-1 for details such as pin number or layout.

Input/output connector (CN0)Power supplyterminal block

Power supplyterminal block

594-2

Series PCW

A

Page 19: PC Wiring System - SMC株式会社ca01.smcworld.com/catalog/BEST-old-en/pdf/ex-pcw.pdfSeries PCW PC Wiring System e-con type is newly added!One-touch connection reduces wiring labor

2

1 3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20 20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

31

2

1F

17 16

1E

15

1D

14

1C

13

1B

12

1A

11

19

10

18

10

18

20

28

19

11

1A

12

1B

13

1C

14

1D

15

1E

16

1F

17

21

29

22

2A

23

2B

24

2C

25

2D

26

2E

27

2F

28292A2B2C2D2E2F

2021222324252627

1 3

2 4

75 9

86 10

1311 15

1412 16

1917 21

2018 22

2523 27

2624 28

3129 33

30 32 34

2

1 3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20 20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

31

2

1F

17 16

1E

15

1D

14

1C

13

1B

12

1A

11

19

10

18

10

18

20

28

19

11

1A

12

1B

13

1C

14

1D

15

1E

16

1F

17

21

29

22

2A

23

2B

24

2C

25

2D

26

2E

27

2F

28292A2B2C2D2E2F

2021222324252627

1 3

2 4

75 9

86 10

1311 15

1412 16

1917 21

2018 22

2523 27

2624 28

3129 33

30 32 34

Circuit DiagramConsult with SMC for the manufacturers and models other than shown as the applicable PLC examples.Refer to page 603-1 for details such as pin number or layout.

Power supplyterminal block

Power supplyterminal block

Power supplyterminal block

Input/output connector (CN0)

PCW-993139A [Applicable PLC example: Keyence Corporation KZ-C32X]

Input/output connector (CN2)Input/output connector (CN1)

PCW-993140A [Applicable PLC example: Keyence Corporation KZ-C32T]Power supplyterminal block Input/output connector (CN0)

Input/output connector (CN2)Input/output connector (CN1)

594-3

PC Wiring System Series PCW

A

Page 20: PC Wiring System - SMC株式会社ca01.smcworld.com/catalog/BEST-old-en/pdf/ex-pcw.pdfSeries PCW PC Wiring System e-con type is newly added!One-touch connection reduces wiring labor

594-4A

Page 21: PC Wiring System - SMC株式会社ca01.smcworld.com/catalog/BEST-old-en/pdf/ex-pcw.pdfSeries PCW PC Wiring System e-con type is newly added!One-touch connection reduces wiring labor

Series PCW32 Point Input/Output Unit

Two pieces are required for 64 points of input/output.

Weight

Ambient temperature

210 g

–25 to 55°C

53.555

4.5

55

1 1F16D40

+

E F 10 11 12 13 14 15 17 18 19 1A 1B 1C 1D 1E

-+-+-+-+-+-+-+-+-+-

C

+

B

-

A

+

9

-

8

+

7

-

6

+

5

-+

3

-

2

+-

16.7

4528

.3

178

4.1

10.510.5

5.1

OUTINAX/ 140- A

0

1 C HC HR S -

(3.6)

(3.7)

PLC connection

Connected to PLC via connection cable.

PLC

Input

PCW-990344APCW-993157APCW-993161A

Output Circuit diagram

PCW-990345APCW-993158APCW-993162A

Page 595-1

Page 595-2

Page 595-3

Specifications

Dimensions

Models

Note) Since the PCW series specifications are included in the common specifications, also refer to the common specifications on page 592.

∗ Refer to page 601 for the junction cable part number.

595 A

Page 22: PC Wiring System - SMC株式会社ca01.smcworld.com/catalog/BEST-old-en/pdf/ex-pcw.pdfSeries PCW PC Wiring System e-con type is newly added!One-touch connection reduces wiring labor

1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33 35 37 39

403836343230282624222018161412108642

22 24 26 28 30 32 34 36 38 40

39373533312927252321

2 4 6 8 10 12 14 16 18 20

191715131197531

Series PCW

Circuit DiagramConsult with SMC for the manufacturers and models other than shown as the applicable PLC examples.Refer to page 603-1 for details such as pin number or layout.

PCW-990344A [Applicable PLC example: OMRON Corporation C200H-ID219]

Input/output connector Power supplyterminal block

Power supplyterminal block

0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115

Input terminal block

PCW-990345A [Applicable PLC example: OMRON Corporation C200H-OD218]

Input/output connector

1151141131121111101091081071061051041031021011001514131211109876543210

Output terminal block

595-1A

Page 23: PC Wiring System - SMC株式会社ca01.smcworld.com/catalog/BEST-old-en/pdf/ex-pcw.pdfSeries PCW PC Wiring System e-con type is newly added!One-touch connection reduces wiring labor

39 37 35 33 31 29 27 25 23 21 19 17 15 13 11 9 7 5 3 1

246810121416182022242628303234363840

1F1E1D1C1B1A19181716151413121110FEDCBA9876543210

1F1E1D1C1B1A19181716151413121110FEDCBA9876543210

40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2

13579111315171921232527293133353739

Consult with SMC for the manufacturers and models other than shown as the applicable PLC examples.Refer to page 603-1 for details such as pin number or layout. Circuit Diagram

Input/output connector Power supplyterminal block

Power supplyterminal block

Input terminal block

PCW-993158A [Applicable PLC example: Mitsubishi Electric Corporation A1SY42]

Input/output connector

Output terminal block

PCW-993157A [Applicable PLC example: Mitsubishi Electric Corporation A1SX42]

595-2

PC Wiring System Series PCW

A

Page 24: PC Wiring System - SMC株式会社ca01.smcworld.com/catalog/BEST-old-en/pdf/ex-pcw.pdfSeries PCW PC Wiring System e-con type is newly added!One-touch connection reduces wiring labor

1 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 33

0

343230282624222018161412108642

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

1514131211109876543210151413121110987654321

2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34

0

33312927252321191715131197531

Consult with SMC for the manufacturers and models other than shown as the applicable PLC examples.Refer to page 603-1 for details such as pin number or layout.

Series PCW

Circuit Diagram

PCW-993161A [Applicable PLC example: Keyence Corporation KZ-C32X]

Input/output connectorPower supplyterminal block

Power supplyterminal block

Input terminal block

PCW-993162A [Applicable PLC example: Keyence Corporation KZ-C32T]

Input/output connector

Output terminal block

595-3A

Page 25: PC Wiring System - SMC株式会社ca01.smcworld.com/catalog/BEST-old-en/pdf/ex-pcw.pdfSeries PCW PC Wiring System e-con type is newly added!One-touch connection reduces wiring labor

Series PCW32 Point Output Reduced Common Unit

∗ Refer to page 601 for the junction cable part number.

Weight

Ambient temperature

130 g

–25 to 55°C

Output Circuit diagram

PCW-993193PCW-993194PCW-993225

Page 596-1

Page 596-1

Page 596-2

4.5

113

131211

112111110

1098

109108107

765

106105

4

104103

32

102

15

115

14

114

1

101100

0+

-

53.555

OD/040LPOUT

CH1

CH

RS-

113

28.3

45

16.7

103

5.1

4.1

10.5 10.5

(3.6)

(3.7)

PLC connection

Connected to PLC via connection cable.

PLC

Two pieces are required for 64 points of input/output.

Specifications

Dimensions

Models

Note) Since the PCW series specifications are included in the common specifications, also refer to the common specifications on page 592.

596 A

Page 26: PC Wiring System - SMC株式会社ca01.smcworld.com/catalog/BEST-old-en/pdf/ex-pcw.pdfSeries PCW PC Wiring System e-con type is newly added!One-touch connection reduces wiring labor

2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40

39373533312927252321191715131197531

15

115

14

114113

1312

112111

1110

110109

98

108107

7

106105

65

104103

43

102101

21

100

0

0

10

1 2

11 12

3 4

13 14

5 6

15 16

7

17 18

8 9

19 1A

A B

1B 1C

C D

1D 1E

E

1F

F

40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2

13579111315171921232527293133353739

PCW-993193 [Applicable PLC example: OMRON Corporation C200H-OD218]

Input/output connector Power supplyterminal block

Power supplyterminal block

Output terminal block

PCW-993194 [Applicable PLC example: Mitsubishi Electric Corporation A1SY42]

Input/output connector

Output terminal block

Consult with SMC for the manufacturers and models other than shown as the applicable PLC examples.Refer to page 603-1 for details such as pin number or layout. Circuit Diagram

596-1

Series PCW

A

Page 27: PC Wiring System - SMC株式会社ca01.smcworld.com/catalog/BEST-old-en/pdf/ex-pcw.pdfSeries PCW PC Wiring System e-con type is newly added!One-touch connection reduces wiring labor

115114113112111110109108107106105104103102101100

151413121110987654321

2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34

0

33312927252321191715131197531

Power supplyterminal block

PCW-993225 [Applicable PLC example: Keyence Corporation KZ-C32T]

Input/output connector

Output terminal block

Circuit DiagramConsult with SMC for the manufacturers and models other than shown as the applicable PLC examples.Refer to page 603-1 for details such as pin number or layout.

596-2

PC Wiring System Series PCW

A

Page 28: PC Wiring System - SMC株式会社ca01.smcworld.com/catalog/BEST-old-en/pdf/ex-pcw.pdfSeries PCW PC Wiring System e-con type is newly added!One-touch connection reduces wiring labor

596-3A

Page 29: PC Wiring System - SMC株式会社ca01.smcworld.com/catalog/BEST-old-en/pdf/ex-pcw.pdfSeries PCW PC Wiring System e-con type is newly added!One-touch connection reduces wiring labor

Series PCW16 Point Input/Output Unit

Input

OutputCircuit diagramPage 597-2

PCW-993051APCW-993052A

Weight

Ambient temperature

125 g

–25 to 80°C

Note) Since the PCW series specifications are included in the common specifications, also refer to the common specifications on page 592.

Terminal Block: DIN Rail Mount Type

5553.5

4.5

55

28.3

45103

16.7IN

OUT

10.5 10.5

(3.7)5.1

4.1

Terminal Block: Box Mount Type

Models Specifications

Models Specifications

Dimensions

Dimensions

Circuit diagramPage 597-2

Input

Output

PCW-993055APCW-993056A

Weight

Ambient temperature

480 g

–25 to 80°CNote) Since the PCW series specifications are

included in the common specifications, also refer to the common specifications on page 592.

33.5139

59

INOUT

CH

(3.7

)

(3)158

55

8

6

67.4

10

40

16 14 16 1614 1614

41.2(2)

65

1.2

4 x M3 x 0.5

2 x ø5 machined for bar ringMounting hole

5 10 1055 55

2525

55 55

6 x ø4

2 x ø8

597 A

Page 30: PC Wiring System - SMC株式会社ca01.smcworld.com/catalog/BEST-old-en/pdf/ex-pcw.pdfSeries PCW PC Wiring System e-con type is newly added!One-touch connection reduces wiring labor

2

4

6

8

10

12

14

16

18

20 19

17

15

13

11

9

7

5

3

1

0 1 2 3 4 5 6 7 8 9 A B C D E F

2

4

6

8

10

12

14

16

18

20 19

17

15

13

11

9

7

5

3

1

0 1 2 3 4 5 6 7 8 9 A B C D E F

PCW-993052A

Series PCW

Circuit Diagram

PCW-993051AInput/outputconnector

Power supply input terminal block

Input/outputconnector

Power supply output terminal block597-1A

Page 31: PC Wiring System - SMC株式会社ca01.smcworld.com/catalog/BEST-old-en/pdf/ex-pcw.pdfSeries PCW PC Wiring System e-con type is newly added!One-touch connection reduces wiring labor

2

4

6

8

10

12

14

16

18

20

1

3

5

7

9

11

13

15

17

19 19

17

15

13

11

9

7

5

3

1

20

18

16

14

12

10

8

6

4

2

0 1 2 3 4 5 6 7 8 9 A B C D E F

2

4

6

8

10

12

14

16

18

20

1

3

5

7

9

11

13

15

17

1919

17

15

13

11

9

7

5

3

1

20

18

16

14

12

10

8

6

4

2

0 1 2 3 4 5 6 7 8 9 A B C D E F

PCW-993055A

PCW-993056A

Circuit Diagram

PC Wiring System Series PCW

Input/outputconnector

Input/outputconnector

Power supply input terminal block

Input/outputconnector

Input/outputconnector

Power supply output terminal block

597-2 A

Page 32: PC Wiring System - SMC株式会社ca01.smcworld.com/catalog/BEST-old-en/pdf/ex-pcw.pdfSeries PCW PC Wiring System e-con type is newly added!One-touch connection reduces wiring labor

53.55579

28.3

45

16.7

69

4.5

5.1

4.1

10.5 10.5

4

CB

32

A

765

FED

1

98

0+

-

(3.6)

(3.7)

∗ Refer to the figure below about the circuit diagram.

Series PCW16 Point Output Reduced Common Unit

Model

Output PCW-993195 Weight

Ambient temperature

80 g

–25 to 80°CNote) Since the PCW series specifications are

included in the common specifications, also refer to the common specifications on page 592.

Specifications

Dimensions

Output terminal block

Power supplyterminal block

0

8 9

1

A

2 3

B C

4

D

5 6

20

19

18

17

16 14

15 13

12

11

10 8

9 7

E F

7

6

5

4 2

3 1

Input/output connectorPCW-993195

Circuit Diagram

598A

Page 33: PC Wiring System - SMC株式会社ca01.smcworld.com/catalog/BEST-old-en/pdf/ex-pcw.pdfSeries PCW PC Wiring System e-con type is newly added!One-touch connection reduces wiring labor

50.549

4528

.3

(3.6) 5.1

4.1

113

10.510310.5

16.7

∗ Refer to the figure below about the circuit diagram.

Series PCW8 Point Branch Unit

Input

Output

PCW-2K0072501PCW-2K0072502

Weight

Ambient temperature

80 g

–25 to 80°CNote) Since the PCW series specifications are

included in the common specifications, also refer to the common specifications on page 592.

Models Specifications

Dimensions

C N O

C N 1 C N 2

PCW-2K0072501 PCW-2K0072502

Circuit Diagram

Input/Output connector Power supply terminal block

Input/Output connector

4.5

19

20 18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

1 2 3 4 5 6 7

F

7

E D C B A 9 8

6 5 4 3 2 1 0

FEDCBA98

1 3 5 7 9 11 13 15 17 19

2018161412108642

0

19 1517 13 911 7 35 1

20 1618 14 1012 8 46 226 4812 101418 1620

15 3711 91317 1519

0

2 4 6 8 10 12 14 16 18 20

191715131197531

8 9 A B C D E F

0123456

89ABCDE

7

F

7654321

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

1820

19

Input/outputconnector

Power supplyterminal block

Power supplyterminal block

Power supplyterminal block

Power supplyterminal block

Input/outputconnector

Output connector Output connectorInput connectorInput connector

599 A

Page 34: PC Wiring System - SMC株式会社ca01.smcworld.com/catalog/BEST-old-en/pdf/ex-pcw.pdfSeries PCW PC Wiring System e-con type is newly added!One-touch connection reduces wiring labor

600A

Page 35: PC Wiring System - SMC株式会社ca01.smcworld.com/catalog/BEST-old-en/pdf/ex-pcw.pdfSeries PCW PC Wiring System e-con type is newly added!One-touch connection reduces wiring labor

PCW 02 005

Series PCWPC Wiring System

Connector Cable

For Connection of PLC Input/Output Card to PCW Unit

• PLC input/output card to PCW branch unit• PLC input/output card to PCW 32 point unit

Lead wire length0.5 m1 m1.5 m2 m3 m5 m

Symbol005010015020030050

Lead wire length

Contact your SMC sales representative regarding connector cables with lead wire lengths other than those in the table above.

Power supply lineYesNo

SymbolNilN

Power supply line

SpecificationsStandard specificationsFor connection of PCW unit compatible with KEYENCE CORP. PLC I/O card (KZ-C32X, KZ-C32T)

Symbol0205

Specifications

DimensionsSeries PCW-02

With power linesPLC connection side

PCW unit connection side

Without power linesPLC connection side

PCW unit connection side

FCN manufactured byFUJITSU LIMITED

40 pin connector

MIL-C-8350340 pin connector

FCN manufactured byFUJITSU LIMITED

40 pin connector

MIL-C-8350340 pin connector

Series PCW-05 With power linesPLC connection side PCW unit connection side

Without power linesPLC connection side PCW unit connection side

MIL-C-8350334 pin connector

MIL-C-8350334 pin connector

MIL-C-8350334 pin connector

MIL-C-8350334 pin connector

601 A

Page 36: PC Wiring System - SMC株式会社ca01.smcworld.com/catalog/BEST-old-en/pdf/ex-pcw.pdfSeries PCW PC Wiring System e-con type is newly added!One-touch connection reduces wiring labor

PCW 04 005 PCW 04 005V

Branch Unit:Connection of PLC Direct Connecting Type

to PCW Unit

Branch Unit:Connection of PLC Direct Connecting Type

to Manifold Solenoid Valves• Branch unit: Connection of PLC direct

connecting type to PCW 16 point unit• Branch unit: Connection of PLC direct

connecting type to PCW 8 point unit

• Branch unit: Connection of PLC direct connecting type to manifold solenoid valves

Lead wire lengthLead wire length

0.5 m1 m1.5 m2 m3 m5 m

Symbol

005010015020030050

Power supply linesPower supply lines

YesNo

Symbol

NilN

Contact your SMC sales representative regarding connector cables with lead wire lengths other than those in the table above.

Power supply linesPower

supply lines

YesNo

Applicable manifoldsolenoid valve kit

G kitJ kit

Symbol

VN

Lead wire length0.5 m1 m1.5 m2 m3 m5 m

Symbol

005010015020030050

Lead wire length

Refer to “Best Pneumatics No. 1” for details re-garding applicable manifold solenoid valves.

Contact your SMC sales representative regarding connector cables with lead wire lengths other than those in the table above.

Dimensions Dimensions

With power lines

Branch unit: PLC direct connecting typeconnection side PCW unit connection side

JM1S manufactured byIDEC Corporation

20 pin connector

MIL-C-8350320 pin connector

With power lines

Branch unit: PLC direct connecting typeconnection side

Manifold solenoid valve connection side

(G kit)

JM1S manufactured byIDEC Corporation

20 pin connector

MIL-C-8350320 pin connector

Branch unit: PLC direct connecting typeconnection side

Without power lines

PCW unit connection side

JM1S manufactured byIDEC Corporation

20 pin connector

MIL-C-8350320 pin connector

Branch unit: PLC direct connecting typeconnection side

Manifold solenoid valveconnection side

(J kit)

Without power lines

JM1S manufactured byIDEC Corporation

20 pin connector

MIL-C-8350320 pin connector

602

Series PCWPC Wiring System

Connector Cable

A

Page 37: PC Wiring System - SMC株式会社ca01.smcworld.com/catalog/BEST-old-en/pdf/ex-pcw.pdfSeries PCW PC Wiring System e-con type is newly added!One-touch connection reduces wiring labor

PCW 01 005 PCW 01 005V

Connection ofPCW Unit to PCW Unit

Connection of PCW Unit to Manifold Solenoid Valves

• Connection of PCW branch unit to PCW 16 point unit

• Connection of PCW branch unit to PCW 8 point unit

• Connection of PCW 8 point unit to PCW 8 point unit

• Connection of PCW branch unit to manifold solenoid valves

• Connection of PCW 8 point unit to manifold solenoid valves

Lead wire length0.5 m1 m1.5 m2 m3 m5 m

Symbol

005010015020030050

Lead wire length

Power supply linesPower supply lines

YesNo

SymbolNilN

Contact your SMC sales representative regarding connector cables with lead wire lengths other than those in the table above.

Lead wire length

0.5 m1 m1.5 m2 m3 m5 m

Symbol

005010015020030050

Lead wire length

Power supply lines

YesNo

Applicable manifoldsolenoid valve kit

G kitJ kit

Symbol

VN

Power supply lines

Refer to “Best Pneumatics No. 1” for details regarding applicable manifold solenoid valves.

Contact your SMC sales representative regarding connector cables with lead wire lengths other than those in the table above.

Dimensions Dimensions

With power lines

PCW unit connection side

MIL-C-8350320 pin connector

MIL-C-8350320 pin connector

Without power lines

PCW unit connection side

PCW unit connection side

PCW unit connection side

PCW unit connection side

PCW unit connection side

MIL-C-8350320 pin connector

MIL-C-8350320 pin connector

With power linesManifold solenoid valve connection side

(G kit)

Manifold solenoid valve connection side (J kit)

MIL-C-8350320 pin connector

MIL-C-8350320 pin connector

Without power lines

MIL-C-8350320 pin connector

MIL-C-8350320 pin connector

603

Series PCWPC Wiring System

Connector Cable

A

Page 38: PC Wiring System - SMC株式会社ca01.smcworld.com/catalog/BEST-old-en/pdf/ex-pcw.pdfSeries PCW PC Wiring System e-con type is newly added!One-touch connection reduces wiring labor

Power supplyterminal block

2

1 3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

2F

27 26

2E

25

2D

24

2C

23

2B

22

2A

21

29

20

28

Input/output connector (CN2)

CS2CS1

CS0

To CS0(Connected to PLC)

3937353331292725232119171513119

8642 40383634323028262422201816141210

3 751

101112131415161718191A1B1C1D1E1F

202122232425262728292A2B2C2D2E2F

These are indicating addresses on the PLC I/O card.However indications vary dependant on each PLC, in this catalog, our common indications are as follows:

15 6th point address out of 32 point1F 16th point address out of 32 point

Input/output connector (CS0)

To CS1(Connected to sensor,

solenoid valve)

To CS2(Connected to sensor,

solenoid valve)

Side to be connected to input/output equipment(20-pin connector)

Powersupply

terminalblock

Connector side to be connected to PLC(40-pin connector)

Powersupply

terminalblock

These are indicating addresses on the PLC I/O cardHowever indications vary dependant on each PLC, in this catalog, our common indications are as follows:

25 22nd address out of 322F 16th address out of 32

603-1

Series PCWCircuit Diagram Instructions

These are indicating addresses on the PLC I/O card.However indications vary dependant on each PLC, in this catalog, our common indications are as follows:

15 6th point address out of 32 point1F 16th point address out of 32 point

These are indicating addresses on the PLC I/O card.However indications vary dependant on each PLC, in this catalog, our common indications are as follows:

15 6th point address out of 32 point1F 16th point address out of 32 point

Numbers on the input/output connector indicate pin number of the connector itself.As pin assignment (pin layout) varies depending on each PLC I/O card, refer to the Circuit Diagram of this product and pin assignment of PLC I/O card when selecting.

To wire the power supply:Connect 24V to (+) and 24G to (-) using the power cable and connector, or alternatively wire using your own cable. This connection offers 24 VDC power supply to each equipment.

You can use this by connecting to the PCW unit together with the input/output unit, or by directly connecting to the manifold solenoid valve.

A

Page 39: PC Wiring System - SMC株式会社ca01.smcworld.com/catalog/BEST-old-en/pdf/ex-pcw.pdfSeries PCW PC Wiring System e-con type is newly added!One-touch connection reduces wiring labor

Be sure to read before handling. Refer to back page 1 for Safety Instructions.

PC Wiring System Precautions 1Series PCW

CautionOperating Environment

CautionMaintenance & Inspection

1. This product is intended for use in general FA equipment. Avoid using this product in machinery or equipment which directly affects human lives or where malfunction or failure can cause extended damage.

2. Do not disassemble this product for repair or rebuilding.

1. Do not drop or bump.Do not drop, bump or apply excessive impacts (500 m/s2 or more) during handling. The PC wiring system unit can be damaged and connected equipment may malfunction.

2. Be careful of incorrect wiring.Incorrect wiring may result in damage to connected equip-ment. The power supply will be short circuited if inputs and outputs are connected incorrectly for the 8 point/16 point in-put/output units following a branch unit.

3. Do not wire with power lines or high voltage lines.To prevent the intrusion of noise and surge from power and high voltage lines into signal lines, perform wiring for the PC wiring system separately (separate conduits) from power lines and high voltage lines.

4. Confirm proper insulation of wiring.Faulty insulation (crossed wiring, insulation defects between terminals, etc.) may result in damage to connected equip-ment, due to the application of excessive voltage or current flowing to the equipment.

5. Tighten screws with the proper tightening torque.If tightened beyond the tightening torque range, the terminal block and screws may be damaged.

6. Avoid subjecting cables to repeated bend-ing or pulling forces.Wiring installations which result in repeated bending stress and pulling force on cables can cause broken wires.

7. Note that the disposition of I/O addresses differs for each PLC manufacturer.General purpose label sets (applicable to all manufacturers) are included, which can be cut as needed and inserted into the terminal label holders.

8. Operate within the rated current.The maximum current capacity for the power supply line on cir-cuit boards of all units is 2.0 A. If the current passing through units such as the branch unit and input/output unit exceeds 2.0 A, connect the power supply line to the same power supply ter-minal and do not allow current to pass through the circuit board.

Operation

CautionMounting, Adjustment & Wiring

Warning1. Confirm the specifications.

Use properly after confirming the specifications. Operation outside the range of specifications (voltage, ambient temperature, impact, etc.) can cause damage, malfunction or fire.

2. Ensure sufficient clearance for maintenance activities.When designing an application, be sure to allow sufficient clearance for maintenance and inspections.

1. To prevent unintended malfunctioning, per-form maintenance regularly.Unintended malfunctioning and misoperation may result in an inability to ensure safety.

2. Do not touch the terminals or internal boards when current is being suplied.Touching terminals or internal boards when current is being suplied may result in malfunctioning or damage with the PC wiring system unit or connected equipment, or electric shock.

1. Absolutely do not use in an atmosphere with explosive gas.The PC wiring system is not an explosion-proof construction. Never use in an atmosphere with an explosive gas since this may cause a serious explosion.

2. Do not use in an environment with tempera-ture cycles.Temperature cycles other than found with normal temperature changes may adversely affect the PC wiring system unit.

3. Do not use in an area where surges are gen-erated.If there are devices or equipment that generate large surges (magnetic lifter, high-frequency induction furnace, motor, etc.) near the connected equipment or PC wiring system unit, the connected equipment may deteriorate or be damaged. Con-sider appropriate measures for any source of power surges and take care with crossed lines.

4. Keep wire scraps and other extraneous ma-terial from getting inside this product.This can cause fire, failure or malfunction, etc. Keep wire scraps and other extraneous material from getting inside this product.

5. Use with consideration for an operating en-vironment with a protective structure.Avoid using the PC wiring system unit where water or oil is spla-shed.

Design & Selection

Caution

604

PC Wiring System Precautions 1Series PCW

A

Page 40: PC Wiring System - SMC株式会社ca01.smcworld.com/catalog/BEST-old-en/pdf/ex-pcw.pdfSeries PCW PC Wiring System e-con type is newly added!One-touch connection reduces wiring labor

When used for PLC output card

PLC output card

e-con type16 point branch unit

16 point output unit

PLC output card

Output branch unit

16 point output unite-con type16 point unit

PLC input card

e-con type16 point branch unit

16 point input unit

When used for PLC input card

PLC input card

Input branch unit

16 point input unite-con type16 point unit

PC Wiring System Precautions 2Be sure to read before handling. Refer to back page 1 for Safety Instructions.

Series PCW

Design & Selection

1. Only the output specification unit can be selected when combining each unit of Ser-ies PCW and Series PCW-EC.Please note: If an input specification unit is used, this may cause damage and/or possible burnout of any connected equipment.

Warning

605A