PCIB-Z102B (Halogen-Free) 18W Non-Dimmable Power (Zhaga 1100lm DLE). 25V to 30.5V / 0.54A Fixed Current. Features. ▶ Constant Voltage / Constant Current Control ▶ High Efficiency ▶ Passive Power Factor Correction ▶ Protection : OVP, SCP and OTP ▶ IEC/EN60598, CE Safety Certifications. - PowerPoint PPT Presentation
Citation preview
Datasheet is subject to change without notice.
www.lginnotek.com
Down Light
Revised 31 August 2012 (REV. 1.0)
Parameter Min Typ. Max Unit Remark
Input Voltage 200 - 305 VAC
Input Current - - 110.6 mA
Input Frequency 47 - 63 Hz
Power Factor 0.9 - - PF At Max Output Load
Inrush Current - - TBD Apk Based on IEC60555
PCIB-Z102B (Halogen-Free)18W Non-Dimmable Power (Zhaga 1100lm DLE)
Features ▶ Constant Voltage / Constant Current Control ▶ High Efficiency ▶ Passive Power Factor Correction ▶ Protection : OVP, SCP and OTP ▶ IEC/EN60598, CE Safety Certifications
Input Specifications
Critical Specifications
Output Specifications
Parameter Min Typ. Max Unit Remark
Output Voltage 25 27 30.5 V
Output Current 513 540 567 mA Fixed Current
Output Current Tolerance -5 - +5 %
Output Ripple Current -40 +40 %
Start-up Time - - 500 ms
25V to 30.5V / 0.54A Fixed Current
1
Input Voltage
OutputVoltage
Output Current
Output Power Efficiency THD Power
Factor
200 - 305VAC 25 - 30.5VDC 0.54A Max. 19.9W > 82% < 40% > 0.9
※ Mass Production
Datasheet is subject to change without notice.
www.lginnotek.com
Down Light
Revised 31 August 2012 (REV. 1.0) 2
Parameter Min Typ. Max Unit Remark
Over Voltage Protection - 43 - V Output Voltage
Over Temperature Protection - 80 - ℃ Case Temperature
Protection Functions
Reliability Specifications
Environmental Specifications
Standards
Parameter Condition Remark
Safety Standards- IEC/EN 60598- Temperature declared thermally protected lamp Driver
Class I (for Europe)Protection type : Auto re-start type
EMI / RFI Standards
- EN 55015:2006+A1+A2- EN 61547:2009- EN 61000-3-2:2006- EN 61000-3-3:2008
Parameter Min Typ. Max Unit Remark
Life Time50 - - kHr @ Tc=55℃25 - - kHr @ Tc=65 ℃
Failure Rate - - - %
- - - %
MTBF kHr
Parameter Min Typ. Max Unit Remark
Operating Temperature -25 - 65 ℃ Case temp.
Storage Temperature -40 - 80 ℃ Ambient temp.
Humidity
- - 95 % Relative humidity for oper-ation
10 - 90 % Relative humidity for stor-age