2
Datasheet is subject to change without notice. www.lginnotek.com Down Light Revised 31 August 2012 (REV. 1.0) Parameter Min Typ. Max Unit Remark Input Voltage 200 - 305 VAC Input Current - - 110.6 mA Input Frequency 47 - 63 Hz Power Factor 0.9 - - PF At Max Output Load Inrush Current - - TBD Apk Based on IEC60555 PCIB-Z102B (Halogen-Free) 18W Non-Dimmable Power (Zhaga 1100lm DLE) Features ▶ Constant Voltage / Constant Current Control ▶ High Efficiency ▶ Passive Power Factor Correction ▶ Protection : OVP, SCP and OTP ▶ IEC/EN60598, CE Safety Certifications Input Specifications Critical Specifications Output Specifications Parameter Min Typ. Max Unit Remark Output Voltage 25 27 30.5 V Output Current 513 540 567 mA Fixed Current Output Current Tolerance -5 - +5 % Output Ripple Current -40 +40 % Start-up Time - - 500 ms 25V to 30.5V / 0.54A Fixed Current 1 Input Voltage Output Voltage Output Current Output Power Efficienc y THD Power Factor 200 - 305VAC 25 - 30.5VDC 0.54A Max. 19.9W > 82% < 40% > 0.9 ※ Mass Production

PCIB-Z102B (Halogen-Free) 18W Non-Dimmable Power (Zhaga 1100lm DLE)

  • Upload
    berit

  • View
    30

  • Download
    0

Embed Size (px)

DESCRIPTION

PCIB-Z102B (Halogen-Free) 18W Non-Dimmable Power (Zhaga 1100lm DLE). 25V to 30.5V / 0.54A Fixed Current. Features. ▶ Constant Voltage / Constant Current Control ▶ High Efficiency ▶ Passive Power Factor Correction ▶ Protection : OVP, SCP and OTP ▶ IEC/EN60598, CE Safety Certifications. - PowerPoint PPT Presentation

Citation preview

Page 1: PCIB-Z102B (Halogen-Free) 18W Non-Dimmable  Power  (Zhaga 1100lm  DLE)

Datasheet is subject to change without notice.

www.lginnotek.com

Down Light

Revised 31 August 2012 (REV. 1.0)

Parameter Min Typ. Max Unit Remark

Input Voltage 200 - 305 VAC

Input Current - - 110.6 mA

Input Frequency 47 - 63 Hz

Power Factor 0.9 - - PF At Max Output Load

Inrush Current - - TBD Apk Based on IEC60555

PCIB-Z102B (Halogen-Free)18W Non-Dimmable Power (Zhaga 1100lm DLE)

Features ▶ Constant Voltage / Constant Current Control ▶ High Efficiency ▶ Passive Power Factor Correction ▶ Protection : OVP, SCP and OTP ▶ IEC/EN60598, CE Safety Certifications

Input Specifications

Critical Specifications

Output Specifications

Parameter Min Typ. Max Unit Remark

Output Voltage 25 27 30.5 V

Output Current 513 540 567 mA Fixed Current

Output Current Tolerance -5 - +5 %

Output Ripple Current -40 +40 %

Start-up Time - - 500 ms

25V to 30.5V / 0.54A Fixed Current

1

Input Voltage

OutputVoltage

Output Current

Output Power Efficiency THD Power

Factor

200 - 305VAC 25 - 30.5VDC 0.54A Max. 19.9W > 82% < 40% > 0.9

※ Mass Production

Page 2: PCIB-Z102B (Halogen-Free) 18W Non-Dimmable  Power  (Zhaga 1100lm  DLE)

Datasheet is subject to change without notice.

www.lginnotek.com

Down Light

Revised 31 August 2012 (REV. 1.0) 2

Parameter Min Typ. Max Unit Remark

Over Voltage Protection - 43 - V Output Voltage

Over Temperature Protection - 80 - ℃ Case Temperature

Protection Functions

Reliability Specifications

Environmental Specifications

Standards

Parameter Condition Remark

Safety Standards- IEC/EN 60598- Temperature declared thermally protected lamp Driver

Class I (for Europe)Protection type : Auto re-start type

EMI / RFI Standards

- EN 55015:2006+A1+A2- EN 61547:2009- EN 61000-3-2:2006- EN 61000-3-3:2008

Parameter Min Typ. Max Unit Remark

Life Time50 - - kHr @ Tc=55℃25 - - kHr @ Tc=65 ℃

Failure Rate - - - %

- - - %

MTBF kHr

Parameter Min Typ. Max Unit Remark

Operating Temperature -25 - 65 ℃ Case temp.

Storage Temperature -40 - 80 ℃ Ambient temp.

Humidity

- - 95 % Relative humidity for oper-ation

10 - 90 % Relative humidity for stor-age