Upload
sergiuchereches
View
114
Download
24
Embed Size (px)
DESCRIPTION
Piese desenat
Citation preview
1A
2 3
B
54A B
Act 02
arh.Torsin Gavril
SC MEGAVOX PROIECT SRLCLUJ-NAPOCA
Plansa:ARHITECTURA-PROPUNEREPLAN PARTER, SECTIUNE TRANSVERSALA T1
Scara: Simbol:
Proiectat
Desenat
arh.Torsin GavrilNr contract:A 2780
Faza:P.T.+D.D.E.
BENEFICIAR: COMANDAMENTUL LOGISTIC INTRUNIT BUCURESTI
OBIECTIV: CONSOLIDARE SI REABILITARE PAVILION S2,CENTRALA TERMICA NOUA SI RETELE UTILITATI INCAZARMA 1114 DEVESELUOBIECT 4: CENTRALA TERMICA IN PAVILION NOUARHITECTURAAMPLASAMENT: UM 01817 DEVESELU CAZARMA 1114 DEVESELU
1:100
1 2 3 54 5 4 3 2 1
1:100
OBIECTIV: CONSOLIDARE SI REABILITARE PAVILION S2,CENTRALA TERMICA NOUA SI RETELE UTILITATI INCAZARMA 1114 DEVESELUOBIECT 4: CENTRALA TERMICA IN PAVILION NOUARHITECTURAAMPLASAMENT: UM 01817 DEVESELU CAZARMA 1114 DEVESELU
BENEFICIAR: COMANDAMENTUL LOGISTIC INTRUNIT BUCURESTI
P.T.Faza:Nr contract:
A 2780arh.Torsin Gavril
Desenat
Proiectat
Simbol:Scara:Plansa:ARHITECTURA-PROPUNEREFATADA PRINCIPALA, FATADA SECUNDARA
SC MEGAVOX PROIECT SRLCLUJ-NAPOCA
arh.Torsin Gavril
Act 04
--3/29--
--3/52A1--
--3/17A--
--3/
3/2-
-
VES300L
--2/29--
--2/52A1--
--2/17A--
--2/
3/2-
-
VES300L
SS-D N 50 -3bar
--1/20M2--
--1/52M2--
--1/20M3--
--1/52M3--
7--1/3/2--
Rg3/4" Rg3/4"Rg3/4"
VA1/2"
VA1/2"
SD24
RCf
RCf
FACRCfRCf RCf
RP
CsfRg3/4"
Rg3/4"
Rg3/4"
Rg3/4"VES1000L
VES 300L Vas de expansiune inchis 300L, camera de gaz umpluta cu azot
VES 1000L Vas de expansiune inchis 1000L, camera de gaz umpluta cu azot
CT 900 kW Cazan din otel cu 3 cai de fum P=900kW
CT 900 kW CT 900 kW
P1 Pompa de inalta eficienta cu sistem electronic de reglare-cu turatie variabila si traductor de presiune diferentiala- circuit cazan - butelie
P3 Pompa de inalta eficienta cu sistem electronic de reglare -cu turatie variabila si traductor de presiune diferentiala - cu 2 rotor circuit incalzire 2 P2
P1 P1
Pompa de inalta eficienta cu sistem electronic de reglare -cu turatie variabila si traductor de presiune diferentiala - cu 2 rotor circuit incalzire 1
P3P2
V3C1 Vana de amestec cu 3 cai Dn 100
V3C2 Vana de amestec cu 3 cai Dn 100
V3C3 Vana de amestec cu 3 cai Dn 100
V3C4 Vana de amestec cu 3 cai Dn 100
V3C1 V3C2
V3C3 V3C4
SD24 Statie de dedurizare
Clapeta sens unic cu mufe CsFY Filtru impuritati cu sita, tip "Y", racord cu mufe
Ros
Rg Robinet de golire (robinet cu obt. sferic si mufe)
Ventil automat de aerisireVA
V3CFAC Filtru de apa autocuratitor, racord cu mufe, Pn10
Senzor de temperatura PT500
BE
BE Butelie de egalizare
D/C
D/C Distribuitor colector
3
--23
0V--
--52
A1-
---
29--
--LO
N--
--LO
N--
--17
A--
--3/
2--
GC1B2--
230V
----
52A
1--
--29
--
--LO
N--
--LO
N--
--17
A--
--3/
2--
GC1B
--1/2M2--
4
--4/
1-- 1
--23
0V--
--21
----
28--
--52
M2-
---
20M
2--
--52
M3-
---
20M
3--
--2M
3--
--2M
2--
--5A
----
3/2-
---
1--
--K
M-B
us--
--LO
N--
MW1B
--1/2M3--
1 Automatizare cascada si comande a celor 2 circuite
2 Automatizarecazan 1
3 Automatizarecazan 2
4 Senzor exterior
SS Supapa de siguranta DN 50 3 bar
SS-D N 50 -3bar
Conducta retur instalatii de incalzire (teava neagra de otel)
Conducta apa rece potabila (teava zincata)
Conducta tur instalatii de incalzire (teava neagra de otel)
Conducta colectare goliri
OBIECTIV: CONSOLIDARE SI REABILITARE PAVILION S2,CENTRALA TERMICA NOUA SI RETELE UTILITATI INCAZARMA 1114 DEVESELUOBIECT 4: CENTRALA TERMICA IN PAVILION NOU - INSTALATII4.1. UTLAJE CTAMPLASAMENT: UM 01817 DEVESELU CAZARMA 1114 DEVESELU
BENEFICIAR: COMANDAMENTUL LOGISTIC INTRUNIT BUCURESTI
CT01
P.T.Faza:Nr contract:
A 2780ing. Muntea Delia
Desenat
Proiectat
Simbol:Scara:Plansa: SCHEMA CT CIRCUIT INCALZIRE
SC MEGAVOX PROIECT SRLCLUJ-NAPOCA
ing. Muntea Delia
--1/20M3--OL 139,7x4,5 OL 139,7x4,5
OL 114,3x3,6OL 114,3x3,6
OL 168,3x4,5
OL 1" OL 1"
OL 114,3x,6
--3/29--
--3/52A1--
--3/17A----
3/3/
2--
VES100L
Rg3 /4 "SD24
RCf
FACRCf
RP
Csf
CT 120 kW
P4
V3C2
3
--23
0V--
--52
A1-
---
29--
--LO
N--
--LO
N--
--17
A--
--3/
2--
GC1B
SS-DN 25 -3bar
Ros32
B 750L
Rg3/4"
Ros32
Ros32
VE80l
Ros3
2Cs
32
Ros32
B 750L
Ros32
Ros32
SS- 6barSS- 6bar
Circuit ACM
Circuit ARRERE
VES 100L Vas de expansiune inchis 100L, camera de gaz umpluta cu azot
CT 120 kW Cazan din otel cu 3 cai de fum P=120kW
P4 Pompa de inalta eficienta cu sistem electronic de reglare-cu turatie variabila si traductor de presiune diferentiala- circuit cazan - boiler
Boiler cu serpentina pentru preparare apa calda menajera, capacitate 750L , din otel cu email sau similar. Este dotat cu, anod de magneziu, termoizolatie, racorduri de apa calda menajera, apa rece de la retea, recirculare, racord apa rece/golire, racord tur/returB 750L
RE Rezistenta electrica 12 kW
Vas expansiune inchis cu membrana cu traversare tip DT5, inclusiv armatura combinata de traversare inchidere si golire "flowjet" cap. 80 litri, pres.de functionare max.10bar -verde VE 80l
OBIECTIV: CONSOLIDARE SI REABILITARE PAVILION S2,CENTRALA TERMICA NOUA SI RETELE UTILITATI INCAZARMA 1114 DEVESELUOBIECT 4: CENTRALA TERMICA IN PAVILION NOU - INSTALATII4.1. UTLAJE CTAMPLASAMENT: UM 01817 DEVESELU CAZARMA 1114 DEVESELU
BENEFICIAR: COMANDAMENTUL LOGISTIC INTRUNIT BUCURESTI
CT02
P.T.Faza:Nr contract:
A 2780ing. Muntea Delia
Desenat
Proiectat
Simbol:Scara:Plansa: SCHEMA CT CIRCUIT PREPARARE ACM
SC MEGAVOX PROIECT SRLCLUJ-NAPOCA
ing. Muntea Delia
Conducta retur cazan-boiler
Conducta apa rece potabilaConducta apa calda menajeraConducta recirculare apa calda menajera
Conducta tur instalatii cazan-boiler
Conducta colectare goliri
Rs 1"
Cs 1"
Rs 1"
P5 recirculare acm
OL 1 1/2"
OL 1 1/2"
OLZn 1 1/4" OLZn 1 1/4"
OLZn 1 1/2"
P5 Pompa recirculare apa calda menajera
OLZn 1"
OL 1 1/4"
Circuit AR
1A
2
3
B
5
4
TE G CT - Tablou electric general centrala termica
Legenda:Conductoare circuit iluminat, montaj ingropat in perete si pe pat cabluriConductoare circuit iluminat siguranta, montaj ingropat in perete si pe pat cabluriCircuit alimentare tablou general TE G CT
Intrerupator hm=1.1-1.2mComutator hm=1.1-1.2mComutator cap-scara hm=1.1-1.2m
Tablou electric
Nota:1. Circuitele electrice montate pe perete vor fi protejate in jgheaburi montate pe perete.2. La alegerea echipamentelor si a materialelor ce vor fi folosite la realizarea instalatiilor se vor respecta instructiunile de utilizare si montaj din fisele tehnologice intocmite de catre producatorii acestora.3. Montajul instalatiilor se va face astfel incat sa nu se afecteze cu nimic structura de rezistenta a constructiei
Legenda:Corp iluminat antiex, 2x40 W cu balast electronic, montaj suspendat, protectie II 2G, EExe II, T4
Corp iluminat antiex, 2x40 W, -iluminat de siguranta pentru continuarea lucrului, cu balast electronic+kit de emergenta 2ore, montaj suspendat, protectie II 2G, EExe II, T4
Corp iluminat etans tip aplica , max. 1x18 W, min.IP 65
Corp iluminat tipmontaj in tavan fals, max. 4x18 W, min.IP 40
Corp iluminat tip aplica tavan, max. 2x36 W, min.IP 65
Corp iluminat siguranta tip luminobloc 1x8W, antiex
Corp iluminat exterior tip proiector, max. 250W, min. IP 65
ci1 ci1 ci1
ci1ci1ci1
ciS
ciS
ciS
ci2 ci2
ci2 ci2
ciS
ciS
ciS
ciS
ciS
ci2ci2
ci2
ci2
TE
G
CT
ciS
ing. M. Robert POP
BENEFICIAR: COMANDAMENTUL LOGISTIC INTRUNIT BUCURESTI
OBIECTIV: CONSOLIDARE SI REABILITARE PAVILION S2, CENTRALA TERMICA NOUA SI RETELE UTILITATI IN CAZARMA 1114 DEVESELU OBIECT4: CENTRALA TERMICA IN PAVILION NOU AMPLASAMENT: UM 01817 DEVESELU CAZARMA 1114 DEVESELU
OB4/E02
P.Th. ing. Delia MunteaDirector
Faza:ing. M. Robert POP
Desenat
Proiectat
Simbol:Scara:Plansa: PLAN CT INSTALATII ELECTRICEINSTALATIA DE ILUMINAT NORMAL SI DE SIGURANTA
SC MEGAVOX PROIECT SRLCLUJ-NAPOCA
1:50
CYABY 4x70+35 mmp
subteran
de la tablou general incinta
TE GD-circuit de rezerva 160A-4P
Nr contract:A2780
1A
2 3
B
54
5
1 12
3
3
1 - Cazan din otel cu 3 cai de fum P=900kW 2 - Cazan din otel cu 3 cai de fum P=120kW 3 - Boiler cu serpentine pentru preparare apa calda menajera 750 l4 - Butelie de egalizare5 - rezervor metalic pt motorina cu pereti dubli cu capacitatea de 1000 l6 - vas de expansiune cazane incalzire 300l7 - vas de expansiune cazan acm 100 l8 - vas de expansiune cazan acm 600 l
Legenda:Circuite forta alimentare utilaje, montaj tub protectie PEL si pe pat cabluriConductoare circuite prize utilizare generala, montaj tub protectie PEL si pe pat cabluriConductoare circuite prize 24 V, montaj tub protectie PEL si pe pat cabluriPriza simplau contact de protectie 230V, hm=1m, cu capac - utilizare generalaPriza simpla 24 V, hm=1m, cu capac - utilizare generalaTablou electricTablou de automatizare
TE G CT- Tablou electric general centrala termicaTAC- Tablou/panou de automatizare si control
TE
G
CT
cp1cp1
cp1
cp2
cp2
cpfjt1cpfjt1
TAC
Legenda:
ing. M. Robert POP
BENEFICIAR: COMANDAMENTUL LOGISTIC INTRUNIT BUCURESTI
OB4/E03
P.Th. ing. Delia MunteaDirector
Faza:ing. M. Robert POP
Desenat
Proiectat
Simbol:Scara:Plansa: PLAN CT INSTALATII ELECTRICEINSTALATIA DE PRIZE SI FORTA
SC MEGAVOX PROIECT SRLCLUJ-NAPOCA
1:50
OBIECTIV: CONSOLIDARE SI REABILITARE PAVILION S2, CENTRALA TERMICA NOUA SI RETELE UTILITATI IN CAZARMA 1114 DEVESELU OBIECT4: CENTRALA TERMICA IN PAVILION NOU AMPLASAMENT: UM 01817 DEVESELU CAZARMA 1114 DEVESELU
Rp
973
jgheab metal 833alimentare arzator cazan incalzire 1dif 30mA
RNr. circ.
S
ctac 1
Destinatie
circuitT
Schema monofilara tablou TE G CT
4P 16A
4P 160A
1660 alimentare pompa circ. cazan 1dif 30mA
2P 16A
alimentare servomotor
vana 3 caidif 30mA
alimentare tablou
bucla automatizare cazan 1
dif 30mA
jgheab metal
jgheab metal
2P 16A
dif 30mAprize CT2000cp1
3 lp
Pe langa rezerva de putere se va lasa o rezerva de spatiu de cel putin 20% din spatiul total al tabloului electric.
18387 17999 18327
10
1000
2P 10A
dif 30mA
Pi=54713W
Pc=43771W
kc=0.8
ci1
6 lliluminat sala cazanelor 600
ct pcc 1
ctv3c 1
ctTA cz1jgheab metal
LEGENDA:
- TABLOU DE AUTOMATIZARE SI CONTROL
2P 6A
2P 6A
PS
Rp
C CC C
COTA
ALEE
ALEE
C OTA
COTA
STB
C OTA
COTA
COTA
COTA
COTA
COTA
COTA CO
TA
COTA
COTA
ALEE
ALEE
C OTA
COTA
GM
C AN
GM
APA
ALEE
ALEE
C CST
L APA
C AN
C AN
R AD I
ERCC
C CC C
C AN -
4M
C AN -
4M
C VA
STL
STL
ALEE
STB
C C
C CC C
PLAT
OU
COTA
PLAT
OUCOT
A
R AD I
ERC V
A
ALEE
ALEE
STB
C CC C
COTA C
OTA
COTA
COTA
C CC C
C VA
COTA
C CC C
COTA
C C
COTA
C C
C VA
ALEE
ALEE
C C
C CC C
ALEE
ALEE
STB C
C C C
PLAT
OU
PLAT
OU
COTA
ALEE
ALEE
C OTA
COTA C
AN
C CC C
COTA
COTA
COTA
COTA
STB
C OTA
C AN
C AN
STL
STL
ALEE
ALEE
C C COT
A
C AN
ETR I
ERC V
A
COTA
COTA
COTA
COTA
GSC F
C
ALEE
ALEE
STL A
LEE
ALEE
C FC
GS
STL
ALEE
ALEE
C C
GS
C C C C
C CCO
TA
C VA
COTA
COTA
C FC
ALEE
ALEE
C C
C AN
ALEE
ALEE
C CC C
COTA
ALEE
ALEE
C FC
C C
COTA
STB
STB
C CC CC CCO
TA
COTA
C VAC V
A
ALEE
ALEE
C FC
STBC
OTA
C C
C AN
COTA
C CC C
STB C
OTA
C T
STB
C FC
C AN
ALEE
ALEE
C FC
C C
COTA
C VA
C VA
C CCO
TA CVA
C VA
C VA
ALEE
C FC
ALEE
C FC
ALEE
ALEE
C OTA C
OTA
COTA
COTAC
OTA
COTA
ALEE
ALEE
Sta t
ie
S ta t
ie
S ta t
ie
S ta t
ie
S ta t
ie
S ta t
ie
S ta t
ie
S ta t
ie
S ta t
ie
S ta t
ie
S ta t
ie
S ta t
ie
S ta t
ie
S ta t
ie
91.1
591
.14
91.0
591
.04
91.0
5
91.1
0
91.0
0
91.2
2
90.9
2
90.7
3
90.7
1
90.7
3
90.8
7
90.9
0
90.4
9
90.6
0
90.4
1
90.2
8
90.2
990
.30
89.7
3
89.7
6
90.1
8
90.2
9
90.3
8
90.0
1
90.2
590
.29
90.2
890
.12 89.7
2
90.1
190
.19
88.6
690.9
1
90.6
590
.64
90.5
7
90.5
8
90.8
7
90.9
590
.98
90.9
7
90.8
2
90.6
6
90.7
090
.65
90.7
1
90.6
2
90.6
4
90.6
0
89.0
390
.70
90.8
290
.84
90.7
8
90.6
390
.64
90.5
8 90.5
6
90.7
8
90.8
2
90.8
790
.92
90.8
1
90.8
5
90.5
490
.53
90.4
5
90.5
5
90.8
4
90.8
8
90.8
7
90.7
590
.72
90.4
6
90.4
390
.43
90.6
790
.64
91.7
7 91.3
4
91.3
2
91.5
7
91.7
3
91.3
4
91.3
091
.26
91.2
791
.42 91
.51
91.3
591
.35
91.6
2
91.8
1
91.8
8
91.8
6
91.9
0
91.4
3
91.5
991
.61
90.9
0
91.0
191
.28
91.2
9
91.3
4
91.3
1
91.2
1
90.1
891
.15
91.4
8
91.3
5
91.1
1
91.2
291
.13
90.9
2
91.2
6
91.2
0 91.1
0 91.2
491
.09
90.8
491
.01
90.9
891
.25
91.1
7
91.3
2
91.1
2
90.7
3
90.7
4
90.6
290
.94
91.1
2
90.7
5
90.7
590
.77
91.2
391
.19
92.0
991.2
2
91.2
791
.26
91.4
491
.45
91.3
9
91.2
491
.21
91.0
7
91.4
4
91.2
2
91.4
1
90.5
4
90.1
8
90.1
790
.12
90.1
1
90.2
3
91.3
3
91.4
1
91.1
2
91.2
5
90.7
6
91.0
791.0
190
.77
90.8
4
90.5
7
90.7
090
.79
90.8
1 91.2
1 90.9
3
90.9
1
91.2
8
90.6
591
.10
90.9
1
90.8
4
90.4
8
90.6
7
90.7
6
90.7
790
.68
90.7
790
.58 90
.33
90.3
6
90.3
8
90.6
2
90.3
7
90.5
1
90.3
8
91.5
191
.55
91.3
8 91.3
2
91.4
1
91.2
691.2
7
91.3
3
91.5
2
91.5
1
91.6
0
91.5
1
91.3
6
91.4
8
91.3
4
91.5
5
91.1
2
91.1
2
91.1
1
90.9
5
90.8
8
90.6
8
90.7
1
90.3
7
90.7
2C O
TA
90.4
0C O
TA
90.5
5C O
TA
Sp - S1sali specialitatiQ=58150 W
A1pavilion administrativQ=118200 W
Apavilion administrativbaza comandamentQ=73515 W
S2sali pregatireQ=74000 W
popotaQ=110500 W
DdormitorQ=550000 W
EinfirmierieQ= 132715 W
Osala de sportQ=207312 W
C.G.corp de gardaQ=61250 W
Latelier autoQ=114408 W
CT+Cpavilion nouQ=8000 W
L = 35.40 m
OBIECTIV: CONSOLIDARE SI REABILITARE PAVILION S2,CENTRALA TERMICA NOUA SI RETELE UTILITATI INCAZARMA 1114 DEVESELUOBIECT 5: RETEA TERMICA DE LA CT NOUA LA PAVILIOANEAMPLASAMENT: UM 01817 DEVESELU CAZARMA 1114 DEVESELU
1/100
BENEFICIAR: COMANDAMENTUL LOGISTIC INTRUNIT BUCURESTI
RT01
P.T.ing. Delia MunteaDirector
Faza:Nr contract:A 2780ing. Muntea Delia
Desenat
Proiectat
Simbol:Scara:Plansa: PLAN RETELE TERM ICE SI A CM
SC MEGAVOX PROIECT SRLCLUJ-NAPOCA
ing. Muntea Delia
L = 35.40 m
H = 3.0 mB = 3.0 mU.4. L = 4 m
L =
3 m
H =
3.0
mB
= 3.
0 m
U.5
.
L = 35.40 m
L =
22.0
9 m
L =
22.0
9 m
L =
14.8
2 m
L =
8.19
m
PF.2.L = 17 m
H = 3.0 mB = 3.0 mU.3.
L = 44.5 mL = 44.5 m
H = 3.0 mB = 3.0 mU.2.
L = 31.9 m L = 31.9 m
L = 3.5 m
L = 3 m
L =
13.9
m
L = 3 m
L = 7 m
L =
3 m
L =
26.9
m
L =
4.3
m
PF.1.
L = 4.5 m
L = 3 m
L =
3 mL = 37.4 m
L = 4.8 m
L =
13.9
m
H = 3.0 mB = 3.0 mU.1.
L = 6.7 m L = 13.3 m
L = 3 m
L =
1 m
L = 42 m
C.V . 1.
L = 11.7 m
L =
15 m
L =
40.8
m
L =
3 m
L = 3 m
L =
3 m
H = 3.0 mB = 3.0 mU.6.
L =
5.5
mL
= 9
m
L = 43 m
PF.4.
L =
39.7
m
C.V . 8.
C.V . 9.
C.V . 3.
C.V . 4.C.V . 5. C.V . 2.
C.V . 6.
C.V . 7.
6
7
65
4 3 2
1
8
9
PF.3.
L = 3.5 m
L =
4.3
m
L = 22,26 m
L =
7.8
m
Camin de vane
Punct fix
Perne de dilatare
LEGENDA:
Retea termica incalzire , tevi negre preizolate in manta PEHD montate direct in sol
Conducta apa calda menajera , teava zincata preizolata in manta PEHD montata direct in solConducta recirculare apa calda menajera, teava zincata preizolata in manta PEHD montata direct in sol
2 6
0,3
x 3,
6/12
5 m
m
2 7
6,1
x 3,
6/14
0 m
m
2 6
0,3
x 3,
6/12
5 m
m
2 6
0,3
x 3,
6/12
5 m
m
2 6
0,3
x 3,
6/12
5 m
m
2 48,3 x 3,2/110 mm
2 76,1 x 3,6/140 mm 2 76,1 x 3,6/140 mm
2 4
8,,3
x 3
,2/1
10 m
m
2 88,9 x 4160 mm 2 88,9 x 4/160 mm
2 4
8,,3
x 3
,2/1
10 m
m
2 114,3 x 4,5/ 200 mm 2114,3 x 4,5/ 200 mm 2139,7 x 5,6/ 225 mm
2139,7 x 5,6/ 225 mm
2139,7 x 5,6/ 225 mm
1 "Zn / 90 mm
1 1/2 "Zn/ 110 mm
1 1/4 "Zn/ 110 mm2 "Zn/ 125 mm
1
1/2
"Zn/
110
mm
1 "Z
n / 9
0 m
m
2 1
39,7
X 5
,6/ 2
25 m
m
2114,3 x 4,5/ 200 mm
1 1/2 "Zn/ 110 mm
1 "Zn/ 90 mm
2 8
8,9
X 4
/ 160
mm
260,3 x 3,6/ 125 mm
2 88,9 x 4/160 mm
91.15
CC
COTA
91.14
CC
ALEE
ALEE
91.05
COTA
COTA
91.04
COTA
91.05
COTA
COTA
91.10
COTA
COTA
91.00
COTA9
1.22
STB
COTA
ALEE
90.92
ALEE
COTA
COTA
90.73
CAN
90.71
GM
APA
90.73
ALEE
ALEE
90.87
APA
90.90
CAN
CAN
90.49
RAD I
E R
COTA
CC
90.60
COTA
CAN -
4M
90.41
CAN -
4M
CVA
90.28
STL
STL
90.29
CC
90.30
CCCC
89.73
PLAT
OUCO T
A
89.76
COTA
RAD I
E R
90.18
GM
CVA
ALEE
90.29
ALEE
STB
90.38
COTA
90.01
COTA
COTA
90.25
COTA
CC
90.29
COTA
90.28
CC
CCCC
90.12
COTA
STL
CC
89.72
CVA
90.11
ALEE
ALEE
90.19
CC
CC
88.66
ALEE
90.91
STB C
C
90.78
90.65
CC
CC
PLAT
OU
90.64
CC
ALEE
90.57
ALEE
COTA
90.58
COTA C
AN
90.87
COTA
90.95
COTA
COTA
90.98
COTA
STB
90.97
ALEE
CAN
90.82
STB
STL
STL
90.66
ALEE
ALEE
90.70
CAN
90.65
ETRI
ERCV
A
90.71
COTA
COTA
90.62
GS
90.64
PLAT
OU
CFC
ALEE
90.60
ALEE
COTA
STL
89.03
CFC
90.70
GS
STL
90.82
ALEE
ALEE
90.84
91.30
CC CC
91.26
CC
90.63
COTA
CC
CVA
90.64
CC
CFC
90.58
ALEE
ALEE
91.35
90.56
CC
CAN
90.78
CC
90.82
CC
COTA
90.87
ALEE
ALEE
90.92
CC
COTA
90.81
CVA
STB
STB
90.85
CCCC
90.54
COTA
90.53
CVACV
A
90.45
ALEE
ALEE
90.55
COTA
90.84
COTA
CC
CAN
90.88
COTA
CC
CC
90.87
COTA
90.75
CT
STB
90.72
CFC
CAN
90.46
CFC
90.43
CC
COTA
90.43
CVA
CC
CVA
90.67
ALEE
CVA
90.64
CVA
CVA
91.77
ALEE
CFC
91.34
ALEE
91.32
ALEE
COTA
91.57
COTA
91.73
COTA
PLAT
OU
COTA
ALEE
91.34
91.09
COTA
90.84
90.77
91.27
91.42
91.22
91.27
91.51
91.35
CC
91.45
CC91
.62
91.24
91.81
91.88
91.86
91.90
Statie
91.43
COTA
91.59
CAN
Statie
91.61
Statie
90.90
91.39
91.01
91.28
91.21
91.07
91.29
91.44
CC91.3
4CC
91.22
91.31
COTA
90.54
91.21
90.18
90.17
90.12
91.15
90.11
COTA
91.48
90.23
91.35
91.41
91.11
COTA
91.12
COTA
90.76CF
C
90.92
91.07
STB9
1.01
90.77
91.20
91.10
90.57
91.24
ALEE
90.70
90.79
90.81CC
91.01
91.21
STB 9
0.93
90.91
91.17
90.65
CC
91.10
91.12
GS
90.91
ALEE
90.84
90.48
90.62
90.76
90.77
91.12
90.68
90.75
CC
COTA
90.58
COTA
90.75
COTA
90.36
90.38
91.23
90.62
91.19
90.37
92.09
ALEE
90.38CF
C
91.55
ALEE
91.26
91.38
ALEE
91.44
91.32
91.22
91.13
CFC
91.26
91.27
91.41
91.33
90.18
CC
90.98
91.25
91.32
90.73
90.74
91.33
90.94
91.25
90.84
91.28
ALEE
90.67
90.77
90.33
90.51
91.51
91.60
91.51
Statie
Statie
91.48
91.34
91.36
91.12
Statie
91.12
Statie
91.11
Statie
Statie
90.95
Statie
Statie
90.88
90.71
Statie
90.37
Statie
90.68
90.72 CO
TA
90.40
COTA
90.55
COTA
SP-S1Sali specialitati
A1Pavilion administrativ S2
Pavilion
APavilion administrativBaza comandament
Popota Depozit alimente
CT+C
Rezervorcombustibil
DDormitor
EInfirmerie
OSala de sport
GUzina electrica
separator nisip+hidrocarburi
C.G Corp de garda
LAtelier auto
decantor
racordPVC-KG 110
PVC-KG 110
PVC-KG 110
PVC-KG 110 PVC-KG 110
PVC-KG 110
PVC-KG 110 PVC-KG 110
PVC-KG 110
racord PVC-KG 110
PVC-KG 110
PVC-KG 110
PVC-KG 110
PVC-KG 200 PVC-KG 200
PVC-KG 200
PVC-KG 200
PVC-KG 200
PVC-KG 200PVC-KG 200
PVC-KG 200
PVC-KG 200
PVC-KG 200
PVC-KG 200
PVC-KG 200
separator nisip+hidrocarburi
SC MEGAVOX PROIECT SRLCLUJ-NAPOCA
Plansa: REABILITARE RETELE CANALIZARE PLAN DE SITUATIE 1A
Scara: Simbol:
Proiectat
Desenat
ing. Morcan CiprianNr contract: Faza:
Director ing. dipl. Delia Muntea
P.T.ing. Morcan Ciprian
RC 02
OBIECTIV: CONSOLIDARE SI REABILITARE PAVILION S2, CENTRALA TERMICA NOUA SI RETELE UTILITATI IN CAZARMA 1114 DEVESELU OBIECT 6: REABILITARE RETELE APA CANAL AMPLASAMENT: UM 01817 DEVESELU CAZARMA 1114 DEVESELU
BENEFICIAR: COMANDAMENTUL LOGISTIC INTRUNIT BUCURESTI
1/100
CM 1HCM 19
CM 18
CM 17
CM 16
CM 15
CM 14
CM 13CM 12CM 11
CM 1C
CM 10
CM 1E
CM 2ECM 6D
CM 5D
CM 4D
CM 1D
CM 1CM 3D
CM 8
CM 7
CM 1BCM 2B
CM 3
CM 1A
CM 1 CM 2
CM 4
CM 1F
CM 7D
CM 2D
racord PVC-KG 110
racord PVC-KG 110
CM 9CM 6
CM 5
LEGENDA:
conducta canalizare proiectataconducta PEHD refulare cota terenului amenajatcamin canalizare menajera proiectatstatie de pompare ape uzate proiectata
CAN
CC
90.11
90.65
COTA
90.40
90.45
COTA
CC 90.10
90.62
CM 1G
spre statia de epurare
90.50
90.42
90.90
CM SPau
COTA91.33
91.40
C.M. 1C.T.A. - 91.00C.R. - 89.60
C.M. 2C.T.A. - 91.10C.R. - 89.49
C.M. 3C.T.A. - 91.12C.R. - 89.29
C.M. 5C.T.A. - 90.40C.R. - 88.63
C.M. 4C.T.A. - 90.29C.R. - 88.94
C.M. 6C.T.A. - 90.50C.R. - 88.38
C.M. 7C.T.A. - 90.58C.R. - 88.12
C.M. 8C.T.A. - 90.57C.R. - 87.91
C.M. 10C.T.A. - 90.72C.R. - 89.32
C.M. 9 - SPau 1 (Q=2,78 l/s)C.T.A. - 90.72C.R. - 87.30
C.M. 11C.T.A. - 90.45C.R. - 88.18
C.M. 12C.T.A. - 90.42C.R. - 89.11
C.M. 13C.T.A. - 90.40C.R. - 88.84
C.M. 14C.T.A. - 90.62C.R. - 88.46
C.M. 15C.T.A. - 90.51C.R. - 88.34
PVC-KG 110
C.M. 16C.T.A. - 90.84C.R. - 88.20
C.M. 17C.T.A. - 90.90C.R. - 87.88
C.M. 18C.T.A. - 90.94C.R. - 87.51
C.M. 19 - SPau 2 (Q=14 l/s)C.T.A. - 91.32C.R. - 87.20
PEHD 110
PEHD 90
C.M. 1 DC.T.A. - 90.30C.R. - 88.90
C.M. 2 DC.T.A. - 90.33C.R. - 88.80C.M. 3 D
C.T.A. - 90.38C.R. - 88.73
C.M. 4 DC.T.A. - 90.77C.R. - 88.50
C.M. 5 DC.T.A. - 90.40C.R. - 88.36
C.M. 6 DC.T.A. - 90.10C.R. - 88.26
C.M. 7 DC.T.A. - 90.23C.R. - 87.98
C.M. 1 GC.T.A. - 90.94C.R. - 89.54
C.M. 1 CC.T.A. - 90.90C.R. - 89.50
C.M. 1 BC.T.A. - 90.90C.R. - 89.50
C.M. 2 BC.T.A. - 90.11C.R. - 89.71
C.M. 1 AC.T.A. - 90.60C.R. - 89.20
A 2780
91.15
CC
COTA
91.14
CC
ALEE
ALEE
91.05
COTA
COTA
91.04
COTA
91.05
COTA
COTA
91.10
COTA
COTA
91.00
COTA9
1.22
STB
COTA
ALEE
90.92
ALEE
COTA
COTA
90.73
CAN
90.71
GM
APA
90.73
ALEE
ALEE
90.87
APA
90.90
CAN
CAN
90.49
RADI
E R
COTA
CC
90.60
COTA
CAN-
4M
90.41
CAN-
4M
CVA
90.28
STL
STL
90.29
CC
90.30
CCCC
89.73
PLAT
OUCO T
A
89.76
COTA
RADI
E R
90.18
GM
CVA
ALEE
90.29
ALEE
STB
90.38
COTA
90.01
COTA
COTA
90.25
COTA C
C
90.29
COTA
90.28
CC
CCCC
90.12
COTA
STL
CC
89.72
CVA
90.11
ALEE
ALEE
90.19
CC
CC
88.66
ALEE
90.91
STB C
C
90.65
CC
CC
PLAT
OU
90.64
CC
ALEE
90.57
ALEE
COTA
90.58
COTA C
AN
90.87
COTA
90.95
COTA
COTA
90.98
COTA
STB
90.97
ALEE
CAN
90.82
STB
STL
STL
90.66
ALEE
ALEE
90.70
CAN
90.65
ETRI
ERCV
A
90.71
COTA
COTA
90.62
GS
90.64
PLAT
OU
CFC
ALEE
90.60
ALEE
COTA
STL
89.03
CFC
90.70
GS
STL
90.82
ALEE
ALEE
90.84
CC
90.78
CC
CC
90.63
COTA
CC
CVA
90.64
CC
CFC
90.58
ALEE
ALEE
90.56
CC
CAN
90.78
CC
90.82
CC
COTA
90.87
ALEE
ALEE
90.92
CC
COTA
90.81
CVA
STB
STB
90.85
CCCC
90.54
COTA
90.53
CVACV
A
90.45
ALEE
ALEE
90.55
COTA
90.84
COTA
CC
CAN
90.88
COTA
CC
CC
90.87
COTA
90.75
CT
STB
90.72
CFC
CAN
90.46
CFC
90.43
CC
COTA
90.43
CVA
CC
CVA
90.67
ALEE
CVA
90.64
CVA
CVA
91.77
ALEE
CFC
91.34
ALEE
91.32
ALEE
COTA
91.57
COTA
COTA
91.73
PLAT
OU
COTA
91.34
COTA
ALEE
ALEE
91.30
COTA CO
TA
91.26
COTA
91.27
COTA
91.42
91.12
91.51
91.35
CC91
.35
CC91
.62
91.81
91.88
91.86
91.90
Statie
91.43
COTA
91.59
CAN
Statie
91.61
Statie
Statie
90.90
91.45
91.39
91.01
91.28
91.21
91.07
91.29
91.44
CC91.34
CC
91.22
91.31
COTA
90.54
91.21
90.18
90.17
90.12
91.15
90.11
COTA
91.48
90.23
91.35
91.41
91.11
COTA
91.22
91.25
COTA
90.76
91.13
91.07
STB
90.92
91.01
91.26
90.84
91.20
91.10
90.70
90.79
91.24
90.81
ALEE
CC 91.2
1
91.09
ALEE
90.93
90.84
90.91
91.01
90.65
90.98
91.25
90.91
91.17
ALEE
91.32
GS
CC
90.84
ALEE
90.48
90.73
90.76
90.74
90.62
90.68
90.77
90.94
90.58
COTA
91.12
90.33
90.75
COTA
90.38
90.75
COTA
90.77
90.37
90.51
91.23
90.38CF
C
91.19
91.51
92.09
91.38
91.22
91.27
91.41
ALEE
91.26
91.26
ALEE
91.27
COTA
91.44
91.33
91.24
CFC
91.52
91.51
91.41
91.26
90.18
CC
91.22
91.34
ALEE
91.33
91.34
ALEE
91.12
CFC
91.07
91.01
90.77
90.57
STB
91.28
91.10
90.67
90.77
CC
90.36
90.62ALEE
91.55
91.32
COTA
91.60
91.51
Statie
91.36
Statie
91.34
91.48
91.55
91.12
Statie
91.12
Statie
91.11
Statie
Statie
90.95
Statie
Statie
90.88
90.71
Statie
90.37
Statie
90.68
90.72 CO
TA
90.40
COTA
90.55
COTA
SP-S1Sali specialitati
A1Pavilion administrativ
S2Pavilion
APavilion administrativBaza comandament
PopotaDepozit alimente
CT+CRezervorcombustibil
DDormitor
EInfirmerie
OSala de sport
GUzina electrica
C.G Corp de garda
LAtelier auto
2 x PEHD 110 mm
2 x PEHD 110 mm2 x PEHD 110 mm
2 x PEHD 110 mm
2 x PEHD 110 mm
2 x PEHD 110 mm
2 x PEHD 110 mm
2 x PEHD 110 mm
2 x PEHD 110 mm
PEHD 75 mm
PEHD 75 mm
PEHD 32 mm
PEHD 25 mm
PEHD 32 mmPEHD 75 mm PEHD 75 mm PEHD 40 mm
PEHD 32 mm PEHD 75 mm
PEHD 75 mm
PEHD 32 mm
PEHD 40 mmPEHD 75 mm
PEHD 75 mm
PEHD 63 mm
PEHD 40 mm
PEHD 75 mm
PEHD 50 mm
PEHD 75 mm
PEHD 75 mm
camera statii pompare apa
rezervor apa 250 mc
put P1 H=80 m
2 x PEHD 110 mm
2 x PEHD 110 mm
CAP T
ARE
o CA
PT.
St
P om
pe
Rez .
St Hidrofor
REZ.
s 20
0
PSI
Statie hidrofor
put P2 H=27 m
SC MEGAVOX PROIECT SRLCLUJ-NAPOCA
Plansa: PLAN RETELE EXTERIOARE APA SI HIDRANTI EXTERIORI
Scara: Simbol:
Proiectat
Desenat
ing. Morcan CiprianNr contract: Faza:
Director ing. Delia Muntea
P.T.ing. Morcan Ciprian
RA01
OBIECTIV: CONSOLIDARE SI REABILITARE PAVILION S2, CENTRALA TERMICA NOUA SI RETELE UTILITATI IN CAZARMA 1114 DEVESELU OBIECT 6: REABILITARE RETELE APA CANAL AMPLASAMENT: UM 01817 DEVESELU CAZARMA 1114 DEVESELU
BENEFICIAR: COMANDAMENTUL LOGISTIC INTRUNIT BUCURESTI
1/100
A 2780
LEGENDA:
retea apa comuna (menajera+hidranti interiori)retea de apa hidranti exterioriretea apa menajeraretea de apa hidranti interiorihidrant exterior
m m
m
m
mm
m
HI
HI
H
I
H
I
H
I
H
I
H
I
H
I
H
I
HIHI
H
I
HI
PEHD 110 mm
PEHD 110 mm
Conducta PE PN10 DN:110
Adaptor PE-OL 110-4"
Vana cu flansa 4"
Adaptor PE-OL 110-4"
Conducta PE PN10 DN:110
DETALIU CAMIN VANE
72 .6 43 7
tr.P.A. ; CV10 - CV12 H12DN 100, L = 72 m
tr.P.A. ; PUT - S.H.PEHD 110 ; L = 102 m
tr.P.A. ; S.P.H1 - CV1 H2PEHD 110, L = 218 m
tr.P.A. ; CV1 H2 - CV2 H3PEHD 100, L = 46 m
CV1 H2
CV2 H3
CV3 H4
CV4 H5
SP H1
CV5 H6CV6 H7CV7 H8CV8 H9CV9 H10
CV10
CV11 H11
CV12 H12
tr.P.A. ; CV2 H3 - CV3 H4PEHD 100, L = 7 m
tr.P.A. ; CV3 H4 - CV4 H5PEHD 110, L = 44 m
tr.P.A. ; CV4 H5 - CV5 H6PEHD 100, L = 70 m
tr.P.A. ; CV5 H6 - CV6 H7PEHD 110, L = 27 m
tr.P.A. ; CV6 H7 - CV7 H8PEHD 110, L = 43 m
tr.P.A. ; CV7 H8 - CV8 H9PEHD 110, L = 35 m
tr.P.A. ; CV8 H9 - CV9 H10PEHD 110, L = 61 m
tr.P.A. ; CV9 H10 - CV10 PEHD 110, L = 127 m
tr.P.A. ; CV11 H11 - CV10 PEHD 110, L = 47 m
m
m
51CC
52CC
57RADIER58
CVA
61STB
68CC
69CC
70CVA
73CC
78CC
80ALEE
81ALEE
82CC 83
CC
84CC
85ALEE
86ALEE
112CAN
113CC
114CC
115COTA
116COTA
117COTA
118COTA
119STB 120
COTA
121CAN
122CAN
125STL
126ALEE127
ALEE
196ALEE
197ALEE
198CFC
205CAN
206COTA
207CC
213STB
214CFC
215CAN
216ALEE
217ALEE
218CFC
219CC
220COTA
221CVA
222CVA
223CC
224COTA
225CVA226
CVA
227CVA
228ALEE
229CFC
230ALEE
231CFC
239COTA
240COTA
241COTA
242COTA
243ALEE
244ALEE
245COTA
246COTA
247ALEE
248ALEE
249COTA
250COTA
251253
COTA
4001Statie
5006Statie
5007Statie
7001Statie
90.70
90.65
89.0390.70
90.78
90.87
90.92
90.81
90.53
90.88
90.75
90.72
90.4690.43
90.43
90.67
90.64
91.42
91.51
91.35
91.35
91.62
91.81
91.88
91.86
91.9091.43
91.59
91.61
91.01
91.2891.29
91.12
91.2590.76
90.84
90.57
90.70
91.28
90.6591.10
90.91
90.84
90.48
90.67
90.76 90.77
90.68
90.77
90.58
90.3390.36
90.38
90.62
90.37
90.5190.38
91.41
91.26
91.27
91.33
91.52
91.5191.26
91.22
91.34
91.34 91.07
91.01
91.55
90.68
90.71
90.37
27690.40COTA
27790.55COTA
CAPTARE
REZERVOR INALTIME
34.90
m
15.36m
17.98
m8.46m
27.16m
C.T.
Pilonet
27.16m
C.T.
27.16m
C.T.
27.16m
C.T.
Rezervor comb.
3.00m
Pavilion S2
REZ.s 200
o CAPT.
St Pompe
Rez.
St H idro for
PSI
Gard imprejmuir
e
H
SC MEGAVOX PROIECT SRLCLUJ-NAPOCA
Plansa: INSTALATII ELECTRICEPLAN DE SITUATIE
Scara: Simbol:
Proiectat
Desenat
ing. M. Robert POPNr contract:A2780/11.07.2013
Faza:Director dr. ing. Delia Muntea
P.Th.
OB6 / E01
OBIECTIV: CONSOLIDARE SI REABIL ITARE PAVILION S2, CENTRALA TERMICA NOUA SI RETELE UTILITATI IN CAZARM A 1114 DEVESELU OBIECT 6: REABILITARE RETELE AP A CANAL AM PLASA MENT: UM 01817 DEVESELU CAZARMA 1114 DEVESELU
BENEFICIAR: COMANDAMENTUL LOGISTIC INTRUNIT BUCURESTI
ing. M. Robert POP
Uzina electrica
GE existent
Legenda:Cablu energie CYABY 5x25mmp, alimentare tablou el TE SP - statie de pompare hidranti exteriori, subteranCablu energie CYABY 5x16 mmp, alimentare tablou el TE PP1-pompa put 1, subteranCablu energie CYABY 5x6 mmp, alimentare tablou el TE PP2-pompa put 2, subteranCablu energie CYABY 4x70+35 mmp, alimentare tablou el TE G SH- statie hidrofor, de la grup electrogen existent-circuit de rezerva 160A-4P, subteranCablu energie CYABY 4x70+35 mmp, alimentare tablou el TE G CT- centrala termica, de la TE GD-circuit de rezerva 160A-4P, subteranCablu energie CYABY 4x120+70 mmp, alimentare tablou el TE G - pavilion S2, de la TE GD-circuit de rezerva 250A-4P, subteranCablu energie CYABY 4x95+50 mmp, alimentare tablou el TE V - bara consumatori vitali pavilion S2, de la GE existent-circuit de rezerva 160A-4P, subteranCablu energie CYABY 5+16 mmp, alimentare tablou el TE SP. a.u. 1 - statie pompare ape uzate nr 1, de la TE GD-circuit de rezerva 25A-4P, subteranCablu energie CYABY 5+16 mmp, alimentare tablou el TE SP. a.u. 2 - statie pompare ape uzate nr 2, de la TE GD-circuit de rezerva 25A-4P, subteranCablu de energie CYABY 3x2,5mmp,alimentare iluminat balizaj Pilonet + cablu semnalizare CSY 4x1.5 mmp, subteran, de la pavilionul S2
Cablu Cyaby 5x25mmp, subteran, alimentare statie de pompare hidranti exteriori de la TE G SH
Cablu CYA BY 5x6 mmp circuit alim entare tablou el TE PP2-pompa put 2, subteran
TE PP1
TE PP2
Cablu CYA BY 5x16 mmp circuit alimentare tablou el TE PP1-pompa put 1, subteran
TE PP1 - Tablou electric pampa put 1TE PP2 - Tablou electric pampa put 2TE GP HE - Tablou electric grup pompare hidranti exterioriTE GP AR+HI - Tablou electric grup pompare apa rece +hidranti interiori
TE GP HE
TE GP AR+HI
TE G SH - Tablou electric general statie hidrofor
1:500
Cablu de energie CY ABY 4x70+35 mmp, subteran, alimentare statie hidrofor, de la Grup electrogen existent-circuit rezerva 160A -4P
Pilonet
Raza de protectie a paratrasnetului Rp=35m
Raza de protectie a paratrasnetului Rp=23m
Cablu de energie CY ABY 4x95+50mmp, subteran, alimentare consumatori vitali Pavilion S2 de la Grup electrogen existent-circuit de rezerva 160A-4P
Cablu de energie CYA BY 3x2,5mmp + cablu semnalizare CSY 4x1.5 mm p, subteran, alim entare iluminat balizaj Pilonet, de la cladire Pavilion S2+tub prot.PEHD
Cablu de energie CYA BY 4x120 + 1x70 mmp, subteran alimentare cladire Pavilion S2 de la TE G D-circuit de rezerva 250A -4P
Cablu de energie CYA BY 4x70+35m mp, subteran alimentare cladire C entrala termica CT de la TE GD- circuit de rezerva 160A , 4P .
TE GD
Cabluri de energie CYABY 4x70+35 mmp, subteran, alimentare statie hidrofor, de la Grup elec trogen existent
Cablu de energie CYA BY 4x120 + 1x70 mmp, subteran alimentare cladire Pavilion S2 de la TE G D
TE GD - Tablou electric general de distributie - existent
SP. au. 1
TE SP. au. 1
TE SP. au. 2
SP. a.u. 2
Cabluri de
energie
CYABY 5
x 16 mmp, s
ubteran,
alimen tare
SP au. 2 d e l
a TE
GD-circuit
de reze rv
a 2 5A-4P
TE SP au. 1 - Tablou electric statie de pompare ape uzate 1TE SP au. 2 - Tablou electric statie de pompare ape uzate 2
Cablu de energie CY ABY 5x16 m mp, subteran,alimentare SP au. 1 de la TE GD-circuit de rezerva 25A-4P
TE GP SH
TE SP
TE G CT
TE SP - Tablou electric statie pompare hidranti exteriori
Pi=7,5 kWPa=7 kW
Pi=8,3 kWPa=4,3 kW
Pi=3,3 kWPa=1,8 kW
Pi=15 kWPa=12,3 kW
Cablu de energie CY ABY 5x16 m mp, subteran,alimentare SP au. 1 de la TE GD(circuit de rezerva 25A-4P)
Cablu de energie CY ABY 5x16 m mp, subteran,alimentare SP au. 1 de la TE GD(circuit de rezerva 25A-4P)
Cablu de energie CY ABY 5x16 m mp, subteran,alimentare SP au. 1 de la TE GD(circuit de rezerva 25A-4P)
Cablu de energie CY ABY 5x16 m mp, subteran,alimentare SP au. 2 de la TE GD-circuit de rezerva 25A-4P
Cablu de energie CYA BY 4x70+35m mp, subteran alimentare cladire C entrala termica CT de la TE GD- circuit de rezerva 160A , 4P .
Protectie cabluri subtraversare din tevi metalice 3x Dn 100mm
Protectie cabluri subtraversare din tevi metalice 3x Dn 100mm
Protectie cabluri subtraversare din tevi metalice 4x Dn 100mm
Protectie cabluri subtraversare din tevi metalice 3x Dn 100mm
Cablu de energie CYA BY 4x120 + 1x70 mmp, subteran alimentare cladire Pavilion S2 de la TE G D-circuit de rezerva 250A -4P
Cablu de energie CY ABY 4x70+35 mmp, subteran, alimentare statie hidrofor, de la Grup electrogen existent-circuit rezerva 160A -4P
Legenda:
Cablu de energie CY ABY 4x70+35 mmp, subteran, alimentare statie hidrofor, de la Grup electrogen existent-circuit rezerva 160A -4P
SC MEGAVOX PROIECT SRLCLUJ-NAPOCA
Plansa: SCHEMA DE PRINCIPIUSTATIE HIDROFOR
Scara: Simbol:
Proiectat
Desenat
ing. Morcan CiprianNr contract: Faza:
Director ing. Delia Muntea
P.T.ing. Morcan Ciprian
RSH05
OBIECTIV: CONSOLIDARE SI REABILITARE PAVILION S2, CENTRALA TERMICA NOUA SI RETELE UTILITATI IN CAZARMA 1114 DEVESELU OBIECT 7: REABILITARE RETELE PUT APA SI REALIZARE STATIE NOUA DE HIDROFOR AMPLASAMENT: UM 01817 DEVESELU CAZARMA 1114 DEVESELU
BENEFICIAR: COMANDAMENTUL LOGISTIC INTRUNIT BUCURESTI
1/100
A2780
alimentare de la pompa submersibiladin put
la instalatia dehidranti exteriori
alimentare de la pompa submersibiladin put
sesizor nivel
vas tampon 3000 l
vas tampon 3000 l
grup pompareconsum menajer+incendiu interior
recipient hidroforcomplet echipat
statietratareapa
CLADIRE EXISTENTA CLADIRE PROIECTATA
Ap - 4"
reteaua de alimentare cu apamenajera + hidranti interiori
pompa de basa pentrupreluarea apelor accidentale
grup pompare apa incendiu exterior(1P+1R+1 pilot)
rezervor existent V=aprox 250 mcV=108 mc - necesarrezerva intangibila LEGENDA:
clapeta de retinere
sesizor de nivel
apometru
conducta de apa
robinet de golire
robinet de trecere
SCHEMA DE PRINCIPIU STATIE HIDROFOR
Rs: 4 "
PEHD 110 mmD: 4 "
PEHD 110 mm
PEHD 110 mm
PEHD 110 mm
Rs 4 "
Rs 4 "
Rs 4 "
Rg 1 " Rs 4"
PEHD 110 mm
Rs 4"
Rs 4" Rs 4"
Rg 1 "Rs: 4 "
Rs 4 "
Rs: 4 "
Rs: 4 "
Rs: 4 "
Rs: 4 "
Rg 1 "Rg 1 "
D: 4 "
Rs
Rg
manometru
distribuitordistribuitor
a
aRs 4 "
Rs 4 "
TE G SH
1
AB
SC MEGAVOX PROIECT SRLCLUJ-NAPOCA
Director ing. Delia Muntea
1:50Plansa: PLAN SHINSTALATII ELECTRICEINSTALATII DE PRIZE SI FORTA
Scara: Simbol:
Proiectat
Desenat
ing. M. Robert POPFaza:P.Th.
OB7/E03
BENEFICIAR: COMANDAMENTUL LOGISTIC INTRUNIT BUCURESTI
ing. M. Robert POP
TE G SH- Tablou electric general statie hidroforTAC- Tablou/panou de automatizare si control
Priza simpla 230 V, hm=1m, cu capac
Priza simpla 24 V, hm=1m, cu capac
Tablou electric metalic
Tablou/panou de automatizare/comanda
Nota:1. Circuitele electrice montate pe perete vor fi protejate in jgheaburi montate pe perete.2. La alegerea echipamentelor si a materialelor ce vor fi folosite la realizarea instalatiilor se vor respecta instructiunile de utilizare si montaj din fisele tehnologice intocmite de catre producatorii acestora.3. Montajul instalatiilor se va face astfel incat sa nu se afecteze cu nimic structura de rezistenta a constructiei
cpfjt1
cpfjt1
Legenda:Conductoare circuit prize 24 V, montaj aparent pe perete in tub protectie HFPRM 16Cablu energie CYABY 4x70+35mmp alimentare tablou general TE G SHCablu energie CYABY 5x25 mmp circuit alimentare tablou el. TE SP - statie pompare hidranti exteriori
OBIECTIV: CONSOLIDARE SI REABILITARE PAVILION S2, CENTRALA TERMICA NOUA SI RETELE UTILITATI IN CAZARMA 1114 DEVESELU OBIECT7: REABILITARE STATIE NOUA HIDROFOR AMPLASAMENT: UM 01817 DEVESELU CAZARMA 1114 DEVESELU
TAC
spre TE PP2 pompa put 2CYABY 5x6 mmpspre TE PP1pompa put 1
CYABY 5x16 mmp
spre Statia de pompare HECYABY 5x25 mmp
De la TE-GE CYABY 4x70+35 mmp(circuit de rezerva 160A-4p)
TE GP AR+HI
alimentare TE GP AR+HICYABY 5x10 mmp
radi
ato
r el
ectr
ic
radiator electric
cre1
cre2
Nr contract:A2780
SC MEGAVOX PROIECT SRLCLUJ-NAPOCA
Director ing. Delia Muntea
OB7/E041:50Plansa: PLAN STATIE POMPE HIDRANTI EXTERIORIINSTALATII ELECTRICEINSTALATII DE ILUMINAT SI FORTA
Scara: Simbol:
Proiectat
Desenat
ing. M. Robert POPFaza:P.Th.
BENEFICIAR: COMANDAMENTUL LOGISTIC INTRUNIT BUCURESTI
ing. M. Robert POP
OBIECTIV: CONSOLIDARE SI REABILITARE PAVILION S2, CENTRALA TERMICA NOUA SI RETELE UTILITATI IN CAZARMA 1114 DEVESELU OBIECT7: REABILITARE STATIE NOUA HIDROFOR AMPLASAMENT: UM 01817 DEVESELU CAZARMA 1114 DEVESELU
Legenda:
Corp iluminat tip aplica etans, max. 1x60 W, U=24V, min.IP 65 si cu rol de iluminat de siguranta
ci1
TE GP HE
de la Statia de hidroforCYABY 5x25mmp
radi
ato
r el
ectr
ic
Nota:1. Circuitele electrice montate pe perete vor fi protejate in jgheaburi montate pe perete.2. La alegerea echipamentelor si a materialelor ce vor fi folosite la realizarea instalatiilor se vor respecta instructiunile de utilizare si montaj din fisele tehnologice intocmite de catre producatorii acestora.3. Montajul instalatiilor se va face astfel incat sa nu se afecteze cu nimic structura de rezistenta a constructiei
Cablu energie CYABY 5x25 mmp circuit alimentare tablou el. TE SP - statie pomparehidranti exterioriConductoare circuit alimentare radiator electric, montaj aparent pe perete in tub protectie HFPRM 20Cablu energie CYABY 5x16 mmp circuit alimentare tablou el. TE GP HE - grup de pompare hidranti exterioriConductoare circuit iluminat la 24V, montaj aparent pe perete in tub protectie HFPRM 16Intrerupator hm=1.1-1.2m, etans
Tablou electric metalic
TE GP HE- Tablou electric/automatizare grup pompare hidranti exteriori
TE SP
TE SP- Tablou electric statie pompare
Nr contract:A2780
Ansamblu existent
de la G
E
de la T
G
inci
nta
TE GE
GE
SC MEGAVOX PROIECT SRLCLUJ-NAPOCA
Scara: Simbol:
Proiectat
Desenat
ing. M. Robert POPNr contract:A2780/11.07.2013
Faza:Director dr. ing. Delia Muntea
P.Th.
OB7 / E07
BENEFICIAR: COMANDAMENTUL LOGISTIC INTRUNIT BUCURESTI
ing. M. Robert POP
2500
CYABY 5x25
Grup electrogen existent 400V , 50Hz
dif 100mA
dif 100mA
Alimentare tablou electric pompa put 1
dif 100mA
5000
Alimentare tablou
electric grup pompare
hidranti exteriori
4000
TE SP4P 50A ,,,40ms
dif 300mA
Rp
5433
SC MEGAVOX PROIECT SRLCLUJ-NAPOCA
Scara: Simbol:
Proiectat
Desenat
ing. M. Robert POPNr contract:A2780/11.07.2013
Faza:Director dr. ing. Delia Muntea
P.Th.
OB7 / E08
BENEFICIAR: COMANDAMENTUL LOGISTIC INTRUNIT BUCURESTI
ing. M. Robert POP
CYABY 5x16Alimentare tablou
electric grup pompare
hidranti exterioriTE GP HE
4P 40A ,,,40ms
dif 100mA
Rp
78CC
79CVA
80ALEE
81ALEE
82CC 83
CC
84CC
85ALEE
86ALEE
189CC
190CC
191CC
192COTA
196ALEE
197ALEE
198CFC
199STB
200COTA201
CC
205CAN
206COTA
207CC
209CC
210STB
211COTA
212CT
213STB
214CFC
215CAN
216ALEE
217ALEE
218CFC
219CC
220COTA
221CVA
222CVA
223CC
224COTA
225CVA226
CVA
227CVA
228ALEE
229CFC
230ALEE
231CFC
5006Statie
5007Statie
90.88
90.87
90.75
90.72
90.4690.43
90.43
90.67
90.64
90.18
90.17
90.12
90.11
91.12
91.2590.76
91.07
91.0190.77
90.84
90.57
90.70
90.7990.81
91.21
90.93
90.91
91.28
90.6591.10
90.91
90.84
90.48
90.67
90.76 90.77
90.68
90.77
90.58
90.3390.36
90.38
90.62
90.37
90.5190.38
90.68
90.71
COTA
27690.40COTA
27790.55COTA
15.36m
8.46m
27.16m
C.T.
27.16m
C.T.
27.16m
C.T.
27.16m
C.T.
RC3.00m
Gard impre
jmuire
H
SC MEGAVOX PROIECT SRLCLUJ-NAPOCA
Plansa: PLAN DE SITUATIE AMPLASAREGOSPODARIE COMBUSTIBIL LICHID
Scara: Simbol:
Proiectat
Desenat
ing. Delia MunteaNr contract:A2780
Faza:P.T.+D.D.E.
OB8 / RC01
OBIECTIV: CONSOLIDARE SI REABILITARE PAVILION S2, CENTRALA TERMICA NOUA SI RETELE UTILITATI IN CAZARMA 1114 DEVESELU OBIECT 8: GOSPODARIE DE COMBUSTIBIL LICHID AMPLASAMENT: UM 01817 DEVESELU CAZARMA 1114 DEVESELU
BENEFICIAR: COMANDAMENTUL LOGISTIC INTRUNIT BUCURESTI
ing. Delia Muntea
1:500
conducta preizolata montata ingropat
32/90 mm (Dint=1")
SC MEGAVOX PROIECT SRLCLUJ-NAPOCA
Plansa: SCHEMA ALIMENTARE COMB. LICHIDGOSPODARIE COMBUSTIBIL LICHID
Scara: Simbol:
Proiectat
Desenat
ing. Delia MunteaNr contract:A2780
Faza:P.T.+D.D.E.
OB8 / RC02
OBIECTIV: CONSOLIDARE SI REABILITARE PAVILION S2, CENTRALA TERMICA NOUA SI RETELE UTILITATI IN CAZARMA 1114 DEVESELU OBIECT 8: GOSPODARIE DE COMBUSTIBIL LICHID AMPLASAMENT: UM 01817 DEVESELU CAZARMA 1114 DEVESELU
BENEFICIAR: COMANDAMENTUL LOGISTIC INTRUNIT BUCURESTI
ing. Delia Muntea
2013-09-25T12:01:42-0700Daniel Croitoru