16
1 System of air quality monitoring in Kosovo and QA/QC of data Letafete Latifi, member of NRC for air quality from Kosovo 02.07.2013 Prizren Republika e Kosovës Republika Kosova - Republic of Kosovo Qeveria – Vlada - Government Ministria e Mjedisit dhe Planifikimit Hapësinor Ministarstvo Sredine i Prostornog Planiranja Ministry of Environment and Spatial Planning AGJENCIONI PËR MBROJTJEN KOSOVSKA AGENCIJA KOSOVO ENVIRONMENTAL E MJEDISIT TË KOSOVËS ZA ZAŠTITU SREDINE PROTECTION AGENCY

System of air quality monitoring in Kosovo and QA/QC of data

  • Upload
    jemima

  • View
    39

  • Download
    0

Embed Size (px)

DESCRIPTION

System of air quality monitoring in Kosovo and QA/QC of data Letafete Latifi, member of NRC for air quality from Kosovo 02 . 07 .201 3 Prizren. Monitoring network in Kosovo Monitoring equipment Softwares for collecting,processing and validation datas - PowerPoint PPT Presentation

Citation preview

Page 1: System of air quality monitoring in Kosovo and QA/QC  of data

1

System of air quality monitoring in Kosovo and

QA/QC of data

Letafete Latifi, member of NRC for air quality from Kosovo

02.07.2013Prizren

Republika e KosovësRepublika Kosova - Republic of Kosovo

Qeveria – Vlada - GovernmentMinistria e Mjedisit dhe Planifikimit HapësinorMinistarstvo Sredine i Prostornog PlaniranjaMinistry of Environment and Spatial Planning

AGJENCIONI PËR MBROJTJEN KOSOVSKA AGENCIJA KOSOVO ENVIRONMENTALE MJEDISIT TË KOSOVËS ZA ZAŠTITU SREDINE PROTECTION AGENCY

Page 2: System of air quality monitoring in Kosovo and QA/QC  of data

1. Monitoring network in Kosovo2. Monitoring equipment3. Softwares for collecting,processing

and validation datas4. Softwares for checking functional

parameters of equipments5. QA/QC of air quality data

Page 3: System of air quality monitoring in Kosovo and QA/QC  of data

Air quality monitoring network in KosovoBased on criteria for determination of monitoring location, according to directive 2008/50/EC,It’s decided that air quality monitoring network in Kosovo will have 12 fixed stations and 1 Mobile station. Locations and stations’ type are shown in map fig.1 and tab.1

Fig.1. map of air quality monitoing network

Page 4: System of air quality monitoring in Kosovo and QA/QC  of data

Air quality monitoring network in KosovoLocal code of stations

Name of station Manager Type statione/type area

Measurement Parameters

KS0101* Prishtine-HMIK KEPA/HMIK Background/Suburban

SO2, NO2, CO,O3, PM10/PM2.5

KS0102* Prishtine-Rilindja KEPA/HMIK Trafik /urban NO2, , PM10/PM2.5KS0103* Drenas-yard of Municipality KEPA/HMIK Background/urban SO2, PM10/PM2.5KS0204* Mitrovicë-Stacioni i

meteorologjsëKEPA/HMIK Background/urban CO,O3, PM10/PM2.5

KS0305 Pejë- Primary school "Lidhja e Prizrenit"

KEPA/HMIK Background/urban SO2, NO2, CO,O3, PM10/PM2.5

KS0406 Prizren-Yard of Municipality KEPA/HMIK Background/urban SO2, NO2, CO,O3, PM10/PM2.5

KS0507* Brezovica-Skying area KEPA/HMIK Background/rural SO2, NO2, CO,O3, PM10/PM2.5

KS0508 Hani i Elezit- Primary School " Ilaz Thaqi"

KEPA/HMIK Background/urban & industrial

SO2, NO2, CO,O3, PM10/PM2.5

KS0609 Gjilan-Yard of Municipality KEPA/HMIK Trafik /urban SO2, NO2, CO,O3, PM10/PM2.5

KS0110 Obiliq- Qendra e mjeksis familjare

KEPA/HMIK Background/industrial

SO2 , NO2, CO,O3, PM10/PM2.5

KS0111 Dardhishte-Shkolla fillore KEPA/HMIK Background/industrial

SO2 , NO2, CO,O3, PM10/PM2.5

KS0112 Palaj-Kosova Mont KEPA/HMIK Background/industrial

SO2 , NO2, CO,O3, PM10/PM2.5

*stationes that are out of function

Tab.1.description of network monitoring

Page 5: System of air quality monitoring in Kosovo and QA/QC  of data

Fixed stations for air quality monitoring

Stations obtain:Analyzers of SO2,NOx(NO,NO2),CO,O3--Teledyn API, seria E and T- Thermo scientifice, serie i and-Horiba

Monitoring of PM10/PM25-Thermo scientifice, Sharp Model 5030-Grimm Model 180 and-Met one Instruments

Sampler of PM10/PM25 and-Derenda-Tecora

Sampler of BTX-Kalma secuencialsensors’ unit of meteorological parameters

Fig.2 View from one of the fixed monitoring stations

Page 6: System of air quality monitoring in Kosovo and QA/QC  of data

Sample preparation lab

Sample preparation for determination of organic compounds:•3 roto-evapuration and •Ekstra

Sample prepartion for determination of heavy metals•Mikroval mineralizues

Fig3.Rota-evapuration

Fig.4.microwave for digestion

Page 7: System of air quality monitoring in Kosovo and QA/QC  of data

Analytical labEquipments for determination of inorganic compounds ICP-MS,- for determination of heavy metalsIC – for determination of anions and cations

Equipments for determination of organic compounds: GC-MS- for determination of PH in airGC-MS me DT- for determination of BTX in air

Fig.5 ICP-MS (Couplied Plazma with induction-mass spectrometria )and IC (Ion Cromatografy )

GC-MS and GC-MS me DT

Page 8: System of air quality monitoring in Kosovo and QA/QC  of data

Calibration labVolumetric system – standard gas production

Concentrated gases sytem

Referent analyzers for SO2, CO, NOx (NO, NO2) and O3 .

Pump for generation of zero air

Calibration Volumetric system

SO2,CO, NOx, O3 analyzers

Page 9: System of air quality monitoring in Kosovo and QA/QC  of data

Process of data production

Validation steps

Page 10: System of air quality monitoring in Kosovo and QA/QC  of data

Collecting, processing and validation data

Data from different types of stations procesed and validated in diferent softwares, depending on analyzers’ producing factory,see pictures belowe.

Software for equipments of Teledyn API serie E

Software for equipments of Thermo scientifice

Software for equipments of Teledyn API serie T

Page 11: System of air quality monitoring in Kosovo and QA/QC  of data

Collected and processed data from three different softwares are transferred in one software (application) which does data statistical analyzes. Software is designed by the assistance of Finish experts during implementation of Twining Project last year.

Statistical analyze and data validation

(Application) where datas are transferred from all monitoring system

Page 12: System of air quality monitoring in Kosovo and QA/QC  of data

EMMA Software for collecting,processing, and validation data from AQ monitoring system

During this year a project which will install server for storing and collecting data from all stations has been implemented.In this server Software EMMA is configured .See fig,x belowe.

Page 13: System of air quality monitoring in Kosovo and QA/QC  of data

This software posseses one interface where the public will have access.Public can see the current data and export it.See fig.x belowe

Page 14: System of air quality monitoring in Kosovo and QA/QC  of data

QA/QC of air quality datas We have to trace the data every day, because equipment malfunction, human

error, power failures and other disturbances can result incorrect data, these must be filtered out.

Raw data is always kept unchanged, and reports of the edits made to the raw data are saved

AQ data is corrected according to calibrations, this has to be done as soon as

possible after the calibration.

Continuous AQ data examination from hourly line chart, both daily data summaries and longer periods gives information about the slide of the zero level or the amplification of the analyser that will be noticed only from long time serie charts

Continuous review of zero and span checks - inform field operators of any equipment malfunction or problem requiring

attention

Page 15: System of air quality monitoring in Kosovo and QA/QC  of data

Can be incorrect values but need to be investigated reasons belowe before removal:-Information from nearby industry, e.g. emission disturbance at the same time?-Effects of meteorology (e.g. wind direction? )-Effect of power failure?-Levels of other pollutants (e.g. O3 vs. NOx)-Time of day/year-Observations from other sites (visual comparison to AQ data from other measurement stations in the same figure)

Proper calibration of automatic monitors is essential for obtaining accurate AQ data.

For each calibration a correction factor (CF) and zero correction (ZC) is calculated.

Through this formula we calculate the corrected value:Corrected value = CF(uncorrected value-ZC)Both CF and ZC change linearly from “start” calibration to “end” calibration .

Page 16: System of air quality monitoring in Kosovo and QA/QC  of data

Thanks for your attention