Telicom Tener

Embed Size (px)

Citation preview

  • 8/16/2019 Telicom Tener

    1/104

    In figures In Words

    1Section - A

    (As per BSR- 2011)

    CIVIL WORKS 21,793,122.34

    2Section - A

    (As per DSR Reprint-2010)CIVIL WORKS 12,694,969.52

    3Section - A

    (As per Non - DSR Items)CIVIL WORKS 12,096,382.13

    4Section - B

    (As per BSR- 2011)PLUMBING WORKS 2,117,664.49

    5Section - B

    (As per DSR Reprint-2010)PLUMBING WORKS 3,460,421.54

    6Section - B

    (As per Non - DSR Items)PLUMBING WORKS 484,540.00

    7Section - C

    (As per BSR-2011)ELECTRICAL WORKS 4,912,539.00

    8Section - C

    (As per Non - DSR Items)ELECTRICAL WORKS 10,122,518.00

    9Section - D

    (As per Non - DSR Items)

    FIRE FIGHTING/FIRE

    PROTECTION SYSTEM1,959,930.00

    INR....................

    (In Figures)

    INR.....................

    (In Words)

    Seal   ....................

    .................... Signature

    BIDDERS FINANCIAL OFFER:

    S.NO NAME OF SUB HEAD ITEMS ESTIMATED COST

     Gross Total Amount (Rs.)

    PROPOSED CONSTRUCTION OF LVL II (4 NO.) TRAUMA CENTRES & LVL III (5 NOS.) TRAUMA CENTRES IN THE STATE OF BIHAR 

    QUOTING SHEET FOR BIDDERS

    NIT No.TCIL/05/527/307/2012

    % above/below Amount in INR after

    adding % above or

    below

    1 / 104

    BIDDERS QUOTING SHEET TCIL

  • 8/16/2019 Telicom Tener

    2/104

    S.NO DESCRIPTION B.S.R 2011DSR-2007

    (Reprint-2010)NON-DSR 

    I CIVIL WORKS   21793122.34 12694969.52 12096382.13LVL II (4 NO.)   10478197.04   5759880.33 6434352.08

    LVL III (5 NOS.)   11314925.30   6935089.19 5662030.05

    II PLUMBING WORKS   2117664.49 3460421.54 484540.00

    LVL II (4 NO.)   997193.44   1613082.79 233740.00

    LVL III (5 NOS.)   1120471.05   1847338.75 250800.00

    III ELECTRICAL WORKS   4912539.00 10122518.00

    LVL II (4 NO.)   2211844.00 4573388.00

    LVL III (5 NOS.)   2700695.00   5549130.00

    IV FIRE FIGHTING/FIRE PROTECTION SYSTEM   1959930.00

    LVL II (4 NO.)   871080.00

    LVL III (5 NOS.)   1088850.00

    PROPOSED CONSTRUCTION OF LVL II (4 NO.) AND LVL III (5 NOS.) TRAUMA CENTRES IN THE STATE OF BIHAR 

    ABSTRACT OF COST

    NIT No.TCIL/05/527/307/2012

    TOTAL COST 69642087.02

    2 / 104

     ABSTRACT OF COST TCIL

  • 8/16/2019 Telicom Tener

    3/104

    BSR DSR 2007 NON-DSR TOTAL AMOUNT

    (i) Civil Work   2619549.26 1439970.08 1608588.02 5668107.36

    (ii) Plumbing Work   249298.36 403270.70 58435.00 711004.06

    (iii) Electrical Work   552961.00 1143347.00 1696308.00

    (iv) Fire Fighting / Fire Protection System   217770.00 217770.00

    3421808.62 1843240.78 3028140.02

    TOTAL 3421808.62 1843240.78 3028140.02TOTAL COST OF BUILDING 'Y'

    GRAND TOTAL OF LVL-II TRAUMA CENTRE

    1 Nos[X+Y]

    GRAND TOTAL OF LVL-II TRAUMA CENTRE

    4 Nos

    8293189.42

    33172757.68

    PROPOSED CONSTRUCTION OF LVL II (4 NOS.) & LVL III (5 NOS.)TRAUMA CENTRES IN THE

    STATE OF BIHAR

    SUMMARY OF COST OF LVL-II

    S.NO NAME OF SUB-HEADAMOUNT

    8293189.42

    Page 3 of 104

    SUMMARY OF COST TCIL

  • 8/16/2019 Telicom Tener

    4/104

    BSR 2011 DSR 2007 NON-DSR  

    I EARTH WORK 34666.73

    II CONCRETE WORK 82554.32 18027.97III REINFORCED CEMENT CONCRETE 619084.04 837549.82

    IV BRICK WORK 309790.20

    V MARBLE WORK 53480.42

    VI WOOD WORK 13327.70 2862.60

    VII STEEL WORK 33045.20

    VIII FLOORING 435132.59 6731.64

    IX ROOFING 5810.78X FINISHING 174407.46 3642.41

    XI ALUMUNIUM 287293.61

    XII WATER PROOFING 177937.61

    XIII PILE WORK 235651.30 71087.25

    XIV CARRIAGE OF MATERIAL 157367.30

    XV NON-SHEDULE ITEMS 1608588.02

    XVI ROAD WORKS 91817.22TOTAL 2619549.26 1031718.91 1608588.02

    ADD COST INDEX @ 39.57% ON DSR 2007   408251.17

    Total (Headwise)   2619549.26 1439970.08 1608588.02

    GRAND TOTAL

    PROPOSED CONSTRUCTION OF LVL II (4 NO.) & LVL III (5 NOS.) TRAUMA CENTRES IN THE

    STATE OF BIHAR 

    SUMMARY OF COST CIVIL WORKS

    S.NO NAME OF SUB-HEADAMOUNT

    5668107.36

    Page 4 of 104

    CIVIL SUMMARY TCIL

  • 8/16/2019 Telicom Tener

    5/104

    1   2.8 Earth work in excavation in foundation trenches or drains (not exceeding 1.5m in

    width or 10 Sq.M on plan) including dressing of sides and ramming ob bottoms,

    lift upto 1.5m, including getting out the excavated soil and disposal of surplus

    excavated soil as directed within a lead of 50m.

    2.8.1 All kinds of soil Cu.M 158.38 132.90 21,048.702   2.26 Filling available excavated earth (excluding rock) in trenches, plinth, sides of 

    foundations etc. in layers not exceeding 20cm in depth, consolidating each

    de osited la er b rammin and waterin lead.

    Cu.M 236.99 42.90 10,166.87

    3   2.29 Surface dressing of the ground including removing vegetation and in equalities

    not exceeding 15cm deep and disposal of rubbish, lead upto 50m and lift upto

    1.5m.2.29.1 All kinds of soil. 100

    Sq.M

    7.22 478.00 3,451.16

    34666.73

    II

    4   4.5 Providing and laying in position cement concrete of specified grade excluding the

    cost of centering and shuttering - All work upto plinth level.4.5.8 1:4:8 (1 cement :4 coarse sand : 8 graded stone aggregate 40 mm nominal size) Cu.M 42.25 1876.80 79,294.80

    5   4.6 Providing and laying cement concrete in retaining walls, return walls, walls ( any

    thickness) including attached pilasters, columns, piers, abutments, pillars, posts,

    struts, buttresses, string or lacing courses, parapets,coping, bed blocks, anchor

    blocks, plain window sills, fillets, etc. upto floor five level, excluding the cost of 

    centrin shutterin and finishin :i   4.6.3 1:2:4 (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size) Cu.M 0.66 3044.50 2,009.37

    ii   4.6.5 1:3:6 (1 cement :3 coarse sand : 6 graded stone aggregate 20 mm nominal size) Cu.M 0.50 2500.30 1,250.15

    TOTAL [II] 82554.32

    III

    TOTAL [I]

    CONCRETE WORK 4.0

    REINFORCED CEMENT CONCRETE 5.0

    BILL OF QUANTITIESCIVIL WORKS

    S

    No

    BSR

     2011DESCRIPTION

    UNIT LVL II QTY RATE

    (in Rs)

     AMOUNT

    (in Rs)

    Page 5 of 104

    CIVIL TCIL

  • 8/16/2019 Telicom Tener

    6/104

    S

    No

    BSR

     2011 DESCRIPTIONUNIT LVL II QTY RATE

    (in Rs)

     AMOUNT

    (in Rs)

    6 5.14   Centring and shuttering including strutting, propping etc. and removal of form

    for:i) 5.14.1   Foundations, footings, bases of columns etc. for mass concrete. Sq.M 76.77 122.85 9,431.19

    ii)   5.14.3 Suspended floors,roofs, landings, balconies and access platform. Sq.M 297.06 179.20 53,233.15

    iii)   5.14.4 Shelves (cast in situ) Sq.M 9.34 179.20 1,673.73

    iv)   5.14.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers. Sq.M 367.53 153.70 56,489.36

    v)   5.14.6 Columns, pillars, piers, abutments, posts and struts Sq.M 225.71 237.70 53,651.27

    vi)   5.14.16 Small lintels not exceding 1.5m clear span, moulding as in cornices, window sills,

    string courses, bands, copings, bed plates, anchor blocks and the like.

    Sq.M 59.00 137.30 8,100.70

    vii)   5.14.17 Edges of slabs and breaks in floors and walls,viii)   5.14.17.1 Under 20 cm wide R.M 15.58 66.70 1,039.19

    ix)   5.14.20 Weather shade, Chajjas, corbels etc. including edges Sq.M 15.59 287.20 4,477.45

    7   5.42 Providing and laying in position machine batched, machine mixed and machine

    vibrated design mix cement concrete of specified grade for reinforced cement

    concrete structural elements, excluding the cost of centring, shuttering finishing

    and reinforcement, M-20 grade reinforced cement concrete.

    i   5.42.1 All work upto plinth level Cu.M 40.52 3336.30 135,186.88ii   5.42 Providing and laying in position machine batched, machine mixed and machine

    vibrated design mix cement concrete of specified grade for reinforced cement

    concrete structural elements, excluding the cost of centring, shuttering finishing

    and reinforcement, M-20 grade reinforced cement concrete.

    5.42.2 All work from plinth level upto floor V levela 5.42.2.1   Walls Columns, pillars, posts cind struts Cu.M. 16.21   3518.80   57,039.75

    b 5.42.2.2   Beams, plinth beams, girders, bressumers, contilevers, Suspended floors lintels

    roofs and staircases including spiral staircases, shelves etc.

    Cu.M. 65.23 3660.30 238,761.37

    619084.04

    IV

    8 6.1A   Brick work with bricks of class designation 100A in foundation and plinth in:6.1.14A   Cement mortar 1:6 (1 cement: 6 coarse sand) Cu.M 38.44 2920.70 112,271.71

    9 6.1.14A+

    6.3ACement mortar 1:6 (1 cement: 6 coarse sand)

    TOTAL [III]

    BRICK WORK 6.0

    Page 6 of 104

    CIVIL TCIL

  • 8/16/2019 Telicom Tener

    7/104

    S

    No

    BSR

     2011 DESCRIPTIONUNIT LVL II QTY RATE

    (in Rs)

     AMOUNT

    (in Rs)

    Extra for Brick work in superstructures above plinth level upto floor V level Cu.M 18.65 3201.10 59,700.52

    10   6.18A Half brick masonry with bricks of class designation 100A in foundations and plinth

    in6.18.4A+

    6.19A

    Cement mortar 1:4 (1 cement : 4 coarse sand)

    Extra for half brick masonry in superstructure above plinth level upto floor V level Sq.M. 300.65 393.70 118,365.91

    11   6.21A Extra for providing and placing in position 2 Nos. 6mm dia. M.S. bars at every

    third course of half brick masonry (with F.P.S. bricks)

    Sq.M. 300.65 64.70 19,452.06

    309790.20

    V

    12   8.2 Providing and fixing 20mm thick mirror polished, machine cut for kitchen

    platforms, vanity counters facias and similar locations of required size of 

    approved shade, colour and texture laid over 20mm thick base cement mortar

    1:4 (1 cement : 4 coarse sand) with joints treated with white cement, mixe* with

    matching pigment- epoxy touch ups, including rubbing, curing etc. complete at all

    i   8.2.6 Granite black

    8.2.6.3 Area of each slab over 0.2 sqm but upto 0.5sqm Granite of any colour and shade Sq.M 17.40 2794.10 48,617.34

    13   8.4 Extra for fixing marble / granite stone over and above corresponding basic item,

    in facia and drops of width up 150 mm with epoxy resin based(Araldite or

    e uivalent adhesive includin cleanin etc. com lete

    R.M 9.12 89.10 812.59

    14   7.43 Stone tile work for wall lining with special adhesive like araldite or equivalent

    over 12mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) including

    pointing in white cement with an admixture of pigment to match the stone shade.

    i   7.43.1 8mm thick (mirror polished and macgune cut edge).

    7.43.1.1 Granite black stone. Sq.M 3.49 1160.60 4,050.49

    53480.42

    VI

    15   9.218 Providing and fixing aluminium sliding door bolt anodised (anodic coating not less

    than grade AC 10 as per IS: 1868) transparent or dyed to required colour or

    shade with nuts and screws etc. com lete:

    MARBLE WORK 8.0

    TOTAL [V]

    WOOD WORK 9.0

    TOTAL [IV]

    Page 7 of 104

    CIVIL TCIL

  • 8/16/2019 Telicom Tener

    8/104

    S

    No

    BSR

     2011 DESCRIPTIONUNIT LVL II QTY RATE

    (in Rs)

     AMOUNT

    (in Rs)i   9.218.1 300x16 mm Each 5.00 192.80 964.00

    ii   9.218.2 250x16 mm Each 16.00 162.90 2,606.40

    16   9.219 Providing and fixing aluminium sliding tower bolt anodised (anodic coating not

    less than grade AC 10 as per IS: 1868) transparent or dyed to required colour or

    shade with screws etc. com lete:i 9.219.1 300x10 mm Each 49.00 86.90 4,258.10

    ii 9.219.4 150x10mm Each 14.00 51.90 726.60

    17 9.222 Providing and fixing aluminium handles anodised (anodic coating not less than grade AC 10

    as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc.

    complete:i 9.222.1 125 mm Each 54.00 59.40 3,207.60

    ii 9.222.2 100 mm Each 7.00 43.00 301.00

    18   9.223 Providing and fixing aluminium hanging floor door stopper anodised (anodic

    coating not less than grade AC 10 as per IS:1868) transparent or dyed to

    required colour and shade with necessary screws etc. complete.

    9.223.2 Twin rubber stopper Each 20.00 63.20 1,264.00

    13327.70

    VII

    19 10.8   Suppling and fixing rolling shutters of approved make, made of required size M.S

    laths inter locked together through their entire length and jointed together at the

    end by end locks mounted on specially designed pipe shaft with brackets, side

    guides and arrangement for inside and outside locking with push and pull

    operation complete including the cost of providing and fixing necessary 27.5 cm

    long wire springs grade No. 2 and M.S top cover pf required thickness for rolling

    shutters.

    10.8.1   80 x 1.25 mm M.S laths with 1.25 mm thick top cover Sq.M 3.78 1445.20 5,462.86

    20 10.9   Providing and fixing ball bearing for rolling shutters Each 2.00 410.60 821.20

    21 10.10   Extra for providing mechanical device chain and crank operation for operating

    rolling shutters:10.10A   Extra for providing grilled rolling shutters Sq.M 0.54 263.30 142.18

    TOTAL [VI]

    STEEL WORK 10.0

    Page 8 of 104

    CIVIL TCIL

  • 8/16/2019 Telicom Tener

    9/104

    S

    No

    BSR

     2011 DESCRIPTIONUNIT LVL II QTY RATE

    (in Rs)

     AMOUNT

    (in Rs)22 10.15   Providing and fixing pressed steel door confirming to IS:4351 manufactured from

    commercial mild steel sheet of 1.25mm thickness including hinges jamb, lock

     jamb, bead and if required angle threshold of mild steel angle of section 50x25

    mm, or base ties of 1.25mm pressed mild steel welded or rigidly fixed together

    by mechanical means, adjustable lugs with split end tail to each jamb including

    steel butt hings 2.5 mm thick with mortar guards, lock strike- plate and shock

    absorbers as specified and applying a coat of approved steel primer after pre -

    treatment of the surface as directed by Enginer-in-charge:

    10.15.1   Profile B R.M. 87.62 303.80 26,618.9633045.20TOTAL [VII]

    Page 9 of 104

    CIVIL TCIL

  • 8/16/2019 Telicom Tener

    10/104

    S

    No

    BSR

     2011 DESCRIPTIONUNIT LVL II QTY RATE

    (in Rs)

     AMOUNT

    (in Rs)VIII

    23 11.34B   Chequerred precast cement concrete tiles 22 mm thick with marble chips of size

    6 mm in footpath & courtyard jointed with neat cement slurry mixed with

    pigment to match the shade of tiles including rubbing and cleaning etc. complete

    on 20 m thick bed of cement mortar 1:4 (1 cement: 4 coarse sand)

    11.34B.2   Medium shade using 50% white cement and 50% grey cement. Sq.M 7.82 723.80 5,660.12

    24   11.48 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed

    with grey cement slurry mixed with pigment to match the shade of the slab

    including rubbing and polishing complete.

    11.48.1 25 mm thick Sq.M 81.39 800.80 65,177.11

    25   11.49 Kota stone slabs 25 mm thick in risers of steps, skirting, dado and pillars laid on

    12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and

     jointed with grey cement slurry mixed with pigment to match the shade of the

    slabs, including rubbing and polishing complete.

    Sq.M 5.96 972.70 5,797.29

    26   11.36 Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622

    (thickness to be specified by the manufacture) of approved make in all colours,

    shades except burgundy, bottle green, black of any size as approved by Engineer

    in-charge in skirting. risers of steps and dados over 12 mm thick bed of cementMortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @

    3.3kg per sqm including pointing in white cement mixed with pigment of 

    matching shade complete.

    Sq.M 57.90 760.90 44,056.11

    27   11.37 Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be

    specified by the manufacturer) of 1st quality conforming to IS:15622 of approved

    make in colours such as White, Ivory, Grey Fume Red Brown, laid on 20 mm

    thick Cement Mortar 1:4 (1 Cement: 4 Coarse sand) including pointing the joints

    with white cement and matching pigment etc., complete.

    Sq.M 77.37 828.40 64,093.31

    28   11.41 Providing and laying polished vitrified floor tiles in different sizes (thickness to be

    specified by the manufacturer) with water absorption's less than 0.08% and

    conforming to IS: 15622 of approved make in all colours and shades, laid on

    20mm thick cement mortar 1:4 (1 cement: 4 coarse sand) including grouting the

     joints with white cement and matching pigments etc., complete.

    i   11.41.2 Size of Tile 60x60cm Sq.M 179.32 1396.10 250,348.65

    435132.59

    FLOORING

    TOTAL [VIII]

    Page 10 of 104

    CIVIL TCIL

  • 8/16/2019 Telicom Tener

    11/104

    S

    No

    BSR

     2011 DESCRIPTIONUNIT LVL II QTY RATE

    (in Rs)

     AMOUNT

    (in Rs)IX

    29   12.38 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement :2 coarse sand : 4

    stone aggregate 10mm and down gauge) including finishing with cement mortar

    1:3 (1 cement : 3 coarse sand) as per standard design:

    12.38.1 In 75x75mm deep chase R.M. 84.85 61.50 5,218.28

    30   12.39 Making khurras 45x45 cm with average minimum thickness of 5 cm cement

    concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm

    nominal size) over P.V.C sheet 1mx1mx400micron, finished with 12mm cementplaster 1:3 (1 cement: 3 coarse sand) and a coat of neat cement rounding the

    edges and making and finishing the outlet complete.

    Each 6.00 98.75 592.50

    5810.78

    X

    31   13.11 12 mm cement plaster of mix:

    13.11.4 1:6 (1 cement: 6 coarse sand) Sq.M 851.01 61.90 52,677.52

    32   13.12 15 mm cement plaster on rough side of single or half brick wall

    13.12.2 1:4 (1 cement: 4 coarse sand) Sq.M 533.51 84.80 45,241.6533   13.24 6 mm cement plaster to ceiling of mix:

    13.24.1 1:3 (1 cement: 3 coarse sand) Sq.M 318.81 58.20 18,554.74

    34   13.36 Extra for providing and mixing water proofing material in proportion

    recommended by the manufacturers:13.36.4 15mm cement plaster 1:4 (1 cement :4 sand) Sq.M 533.51 4.00 2,134.04

    35   13.92 Wall painting with plastic emulsion paint of approved brand and manufacture to

    give an even shed:13.92.1 Two or more coats in new work. Sq.M 1169.82 47.00 54,981.54

    36   13.93 Painting with synthetic enamel paint of approved brand and manufacture to give

    an even shade:13.93.1 Two or more coats on new work Sq.M 19.71 41.50 817.97

    174407.46

    XI PILE WORK 23.0

    ROOFING 12.0

    TOTAL [IX]

    FINISHING 13.0

    TOTAL [X]

    Page 11 of 104

    CIVIL TCIL

  • 8/16/2019 Telicom Tener

    12/104

    S

    No

    BSR

     2011 DESCRIPTIONUNIT LVL II QTY RATE

    (in Rs)

     AMOUNT

    (in Rs)37 23.3   Boring providing and installing cast in situ single rubber reamed piles of specified

    diametre and length below pile cap in cement concrete piles with mix 1:1.5:3 (1

    Cement: 1.5 Coarse Sand :3graded stone aggregate 20mm nominal size) to carry

    a safe working load not less than specified. excluding the cost of steel

    reinforcement but including the cost of boring with bentonite solution and the

    legth of the pile to be embedded in pile cap etc all complete. (Length of pile for

    payment shall be measured upto the bottom of pile cap).

    23.3.1   300mm dia piles RM 345.00 373.70 128,926.50

    38 23.7   Vertical load testing of pile in accordance with IS 2911 (Part IV) includinginstallation of loading plateform and preparation of pile head or construction of 

    test cap and dismantling of test cap after test etc. complete as per specification & 

    the direction of En ineer-in-Char e.23.7.2 Group of two or more pile

    23.7.2.1 Upto 50 tonne capacity each Per test 2.00 53362.40 106,724.80

    235651.30

    XII

    39   24.1 Providing and fixing aluminium work for doors, windows, ventilators and

    partitions with extruded built up standard tubular and other sections of approved

    make conforming to IS: 733 and IS: 1285, anodised transparent or anodic

    coating of grade AC15), fixed with rawl plugs and screws or with fixing clips, orwith expansion hold fasteners including necessary filling up of gaps at junctions,

    at top, bottom and sides with required PVC/neoprene felt etc. Aluminium

    sections shall be smooth, rust free straight, mitred and jointed mechanically

    wherever required including cleat angle, Aluminium snap beading for glazing /

    panelling, C.P. brass / stainless steel screws, all complete as per architectural

    drawings and the directions of Engineer-in-charge. (Glazing and panelling to be

     i   24.1.1 Fox fixed portion kg 477.50 359.00 171,422.50

    ii   24.1.2 For shutters of doors, windows & ventilators including providing and fixing hinges

     / pivots and making provision for fixing of fittings wherever required including thecost of PVC / neoprene gasket required (Fittings shall ber paid for separately).

    kg 200.12 376.20 75,285.14

    TOTAL [XI]

     ALUMINIUM WORKS 24.0

    Page 12 of 104

    CIVIL TCIL

  • 8/16/2019 Telicom Tener

    13/104

    S

    No

    BSR

     2011 DESCRIPTION

    UNIT LVL II QTY RATE

    (in Rs)

     AMOUNT

    (in Rs)40   24.2 Providing and fixing 12mm thick prelaminated three layer medium density

    (exterior grade) particle board Grade I, Type II, conforming to IS : 12823 bonded

    with phenol for maidhyde synthetic resin, of approved brand and manufacture in

    panelling, fixed in aluminium doors, windows shutters and partition frames with

    C.P. brass / stainless steel screws etc. complete as per architectural drawings and

    directions of engineer-in-charge.24.2.2 Pre-laminated particle board with decorative lamination on both Sides Sq.M 2.69 980.40 2,637.28

    41   24.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and

    partitions etc. with PVC / neoprene gasket etc. complete as per the architectural

    drawings and the directions of engineer-in-charge. (Cost of aluminium snap

    beading shall be paid in basic item):

    24.3.1 With glass panes of 4.0 mm thickness (weight not less than 10.0kg/sqm) Sq.M 58.15 652.60 37,948.69

    287293.61

    XIII

    42   25.8   Providing and laying integral cement based water proofing treatment includingpreparation of surface as required for treatment of roofs, balconies, terraces etc,

    conisting of following operations: a) Applying and grouting a slurry coat of neat cementusing 2.75 kg/sqm. of cement admixed with proprietary water -proofing compound

    cleaning the surface before treatment, (b) Laying cement concrete using broken bricks /

    brick bats 25mm to 100 mm size with 50% of cement mortar 1:5 (1 cement: 5 coarse

    sand) admixed with proprietary water proofing compound conforming to IS: 2645 over

    20 mm thick layer of cement mortar of mix 1:5 (1 cement : 5 coarse sand) admixed with

    proprietary water proofing compound conforming to IS: 2545 to required slope and

    treating similarly the adjoining walls upto 300 mm height including rounding of junctions,

    or walls and slabs (c) After two days of proper curing applying a second coat of cement

    slurry admixed with proprietary water proofing compound conforming to IS: 2645. (d)

    Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement : 4

    coarse sand) admixed with proprietary water proofing compound conforming to IS: 2645and finally finishing the surface with trowel with neat cement slurry and making pattern

    of 300x300 mm square. (e) The whole terrace so finished shall be flooded with water for

    a minimum period of two weeks for curing and for final test. All above operations to be

    done in order and as directed and specified by the Engineer-in-Charge:

    TOTAL [XII]

    WATER PROOFING 25.0

    Page 13 of 104

    CIVIL TCIL

  • 8/16/2019 Telicom Tener

    14/104

    S

    No

    BSR

     2011 DESCRIPTION

    UNIT LVL II QTY RATE

    (in Rs)

     AMOUNT

    (in Rs)

    25.8.1 With average thickness of 120mm and minimum thickness at khurra as 65 mm. Sq.M 373.74 476.10 177,937.61

    177937.61

    XIV

    43   BRICKS 1000 Nos 45.99 473.60 21,780.86

    44   Coarse Sand Cu.M 69.25 510.00 35,317.50

    45   Stone Aggregate Cu.M 92.67 1082.00 100,268.94

    157367.30

    XV

    46 DSR 4.17  Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement :3

    coarse sand : 6 graded stone aggregate 20mm nominal size) over 75mm bed bydry brick ballast 40mm nominal size well rammed and consolidated and grouted

    with fine sand including finishing the top smooth

    Sq.M 80.97 222.65 18,027.97

    18027.97

    XVI

    47 5.22 Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position

    and binding all complete.

    5.22.6 Thermo Mechanically Treated bars Kg 6276.73 42.70 268,016.37

    48 5.22A Reinforcement for R.C.C. work including straightening, cutting, bending, placing in posit ion

    and binding all complete. Above Plinth Level

    5.22A.6 Thermo Mechanically Treated bars. Kg 13338.02 42.70 569,533.45837549.82

    XVII

    49 9.95   Providing and fixing ISI marked aluminium butt hings ISI marked anodised

    (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed

    to refquired colour or shade with necessary screws etc. complete:

    9.95.4   100x63x4 mm Each 52.00 55.05 2,862.60

    TOTAL [XVI]

    WOOD WORK 9.0

    CARRIAGE OF MATERIALS

    TOTAL [XIV]

    DSR 2007 ITEM

    CONCRETE WORK 4.0

    TOTAL [XV]

    REINFORCED CEMENT CONCRETE 5.0

    TOTAL [XIII]

    Page 14 of 104

    CIVIL TCIL

  • 8/16/2019 Telicom Tener

    15/104

    S

    No

    BSR

     2011 DESCRIPTION

    UNIT LVL II QTY RATE

    (in Rs)

     AMOUNT

    (in Rs)2862.60

    XVIII

    50 11.21   Providing and fixing 10 mm thick acid and or alkali resistant tiles of approved

    make and colour using acid and or alkali resisting mortar bedding and joints filld

    with acid and or alkali rsisting cement as per IS: 4457 complete as per the

    direction of Engineer-in charge

    11.21.1   In flooring on a bed of 10 mm thick mortar 1:4 (1 appropriatecement: 4 coarse

    sand)11.21.1.1   Acid and alkali resistant tile Sq.M 6.43 873.00 5,613.39

    51 11.21.2   In dado / skirting on 12 mm thick mortar 1:4 (1 appropriate cement: 4 coarse

    sand)11.21.2.1   Acid and alkali resistant tile Sq.M 1.23 909.15 1,118.25

    6731.64

    XIX

    52   13.46 Finishing walls with Acrylic Smooth exterior paints of required shade:

    13.46.1 New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including base

    coat of water proofing cement paint applied @ 2.20kg/10 sqm).

    Sq.M 72.27 50.40 3,642.41

    3642.41XX

    53 20.4 Extra over item No. 20.3 for providing additional bulb in under reamed piles, under specified

    dia meter (Only the quantity of extra bulbs are to be paid)

    20.4.1 300 mm dia piles Each 69.00 1030.25 71,087.25

    71087.25

    XXI

    54 NS.1 VINYL FLOORING

    Providing and fixing 3mm thick Antistatic and Electro Conductive vinyl flooring in roll form laid

    over 40mm thick PCC floor 1:2:4 type B1 with adhesive as recommended by the

    manufacturers.

    Sq.M 105.25 2198.00 231,339.50

    55 NS.2 Fabrication, supply and installation of SS 304 grade railing made of 38mm baluster and

    38mm top rail of 1.6mm thickness with 3 mid rails of 12 OD tube connected with CNC

    machine made. Modular connectors fixed with dash fastners. Centre distance between each

    baluster 900mm & 950mm high baluster

    R.M. 15.07 9154.00 137,950.78

    TOTAL [XIX]PILE WORK 20.0

    TOTAL [XX]

    NON SCHEDULE ITEMS

    TOTAL [XVII]

    FLOORING

    TOTAL [XVIII]

    FINISHING 13.0

    Page 15 of 104

    CIVIL TCIL

  • 8/16/2019 Telicom Tener

    16/104

    S

    No

    BSR

     2011 DESCRIPTION

    UNIT LVL II QTY RATE

    (in Rs)

     AMOUNT

    (in Rs)56 NS.3 Providing and applying 1 coat of primer +repair check with exterior grade putty + Two coats

    of Mamrino a Lime Plaster as per approved shade and finish.

    Sq.M 461.25 1736.00 800,730.00

    57 NS.4 Providing and fixing ISI marked 35mm thick flush pre-laminated door shutter (with 1mm thick

    lamination on both sides) core of block boazed construction with frame of 1st class hazd

    wood and well matched commercial - 3 ply veneering and as approved by engineer in-

    charge.

    Sq.M 32.25 2859.00 92,202.75

    58 NS.5 Supplying of good earth by mechanical transport including loading, unloading and stacking

    including royalty at site (earch measured in stock will be reduced by 20% for voids)

    Cu.M 80.25 165.08 13,247.67

    59 N.S.6 ANTITERMITE TREATMENT

    Diluting and injecting chemical emulsion for PRE-CONSTRUCTIONAL Anti-termite treatment

    and creating a continous chemical barrier , wall trenches, top surface of plinth filling, along

    the external perimeter of building, over the top surface of consolidated earth of which apron

    is to be laid, surroundings of pipes and conduits etc. complete as per specification. (Plinth

    area of the building at ground floor only shall be measured for payment). Chlorpyriphos

    Emulsifiable concentrate of 20% with 1% Concentration.

    Sq.M 367.00 401.00 147,167.00

    60 N.S-7 Supplying & fixing of sliding window latch with locking arrangement of approved make. Each 48.00 230.00 11,040.0061 NS.8   Providing and applying cementitious crystalline based water proofing for concrete

    rafts, walls, water wanks slabs, concrete roofs etc. with Krystol T-1 system. The

    application to be done from +Ve(positive) side on a wet open pore concrete

    surface with brush @ 1 Kg/Sq.M. as per manufacturer specification

    Sq.M 373.74 468.00   174,910.32

    1608588.02TOTAL [XXI]

    Page 16 of 104

    CIVIL TCIL

  • 8/16/2019 Telicom Tener

    17/104

    S

    No.

     DSR-2007

    (Reprint-2010)DESCRIPTION

    UNIT QTY RATE

    (in Rs)

     AMOUNT

    (in Rs)

    1 4.1   Providing and laying in position cement cncrete of specified grade excluding

    the cost of centring and shuttering - all work upto plinth level.

    4.1.8   1:4:8 (1 cement:4 coarse sand : 8 graded stone aggregate 40 mm nominal

    size)

    Cu.M 1.80 2449.00 4408.20

    2 16.1   Preparation and consolidation of sub grade with power road roller of 8 to 12

    tonne capacity after excavating earth to an average of 22.5 cm. depth,

    dressing to camber and consolidating with road roller including making

    good the undulations etc. and re-rolling the sub grade and disposal of 

    sur lus earth lead u to 50 metres.

    Sq.M 135.00 33.90 4576.50

    3 16.2   Extra for compaction of earth work in embankment under optimum

    moisture conditions to give at least 95% of the maximum dry densite

    roctor densit .

    Cu.M 47.25 4.50 212.63

    4 16.3   Supplying and stacking at site.

    16.3.1   90 mm to 45 mm size stone aggregate Cu.M 13.50 742.30 10021.05

    16.3.2   63 mm to 45 mm size stone aggregate Cu.M 13.50 768.45 10374.08

    16.3.3   53 mm to 22.4 mm size stone aggregate Cu.M 13.50 810.55 10942.43

    5 16.4   Laying spreading and compacting stone aggregate of specified sizes to

    WBM specifications including spreading in uniform thickness, hand picking,

    rolling with 3 wheeled road / vibratory roller 8-10 tonne in stages to proper

    grade and camber, applying brooming requisite type of screening / binding

    material to fill up interstices of coarse agregate watering and compacting

    to the re uired densit .

    Cu.M 40.50 192.55 7798.28

    6 16.6   Supplying, stacking and Spreading 6 mm thick red bajri, watering and

    rolling complete including preparation of the surface and rolling.

    16.6.1   With road roller / hand roller. Sq.M 135.00 6.70 904.50

    ROAD WORK

    XVI ROAD WORKS

    Page 17 of 104

    CIVIL (ROAD) TCIL

  • 8/16/2019 Telicom Tener

    18/104

    S

    No.

     DSR-2007

    (Reprint-2010) DESCRIPTION

    UNIT QTY RATE

    (in Rs)

     AMOUNT

    (in Rs)7 16.30   Providing and applying tack coat using hot straight run bitumen of grade 80

     / 100 including heating the bitumen, spraying the bitumen with

    mechanically operated spray unit fitted on bitumen boiler, cleaning and

    re arin the existin road surface as er s ecifications:16.30.1   On W.B.M. @ 0.75 kg / sqm. Sq.M 135.00 23.90 3226.50

    8 16.33   2.5 cm premix carpet surfacing with 2.25 cum and 1.12 cum of stone

    chippings of 13.2mm and 11.2mm size respectively per 100 sqm and 52

    kg. and 56 kg. of hot bitumen per cum of stone chippings of 13.2 mm and

    11.2 mm size respectively including a tack coat with hot straight run

    bitumen including consolidation with road roller of 6 to 9 tonne capacity

    etc. complete. (tack coat to be paid for separately):

    16.33.1   With paving Asphalt 80/100 heated and then mixed with solvent at the rate

    of 70 grams per kg of asphalt.

    Sq.M 135.00 100.35 13547.25

    9 16.48   Painting road surface markeing with adequate No. of coats to IS: 164, on

    bituminous surface in white/yellow shade including cleaning the surface of 

    all dirt, scales, oil, grease and foreign material etc. complete.

    16.48.1   New work (Two or more coats) Sq.M 20.25 58.10 1176.53

    10 16.63   Providing and laying and making kerb channel 30cm wide and 50 mm thickof cement concrete 1:3:6 (1 cement: 3 coarse sand:6 graded stone

    aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40 mm

    nominal size well rammed and consolidated and grouted with fine sand

    including finishing the top smooth etc. complete and as per direction of 

    En ineer-in-char e.

    Sq.M 18.00 198.80 3578.40

    11 16.69   Providing and laying at or near ground level factory made kerb stone of M-

    25 grade cement in position to the required line, level and curvature

     jointed with cement mortar 1:3 (1 cement: 3 coarse sand) including

    making joints with or without grooves (thickness of joints except at sharp

    curve shall not to more than 5mm) including making drainage opening

    whereever required ccomplete etc. as per direction of Engineer-in-charge(length of finished kerb edging shall be measured for payment). (Precast

    C.C. kerb stone shall be approved by Engineer-in-charge)

    Cu.M 4.95 4252.70 21050.87

    91817.22TOTAL [XVI]

    Page 18 of 104

    CIVIL (ROAD) TCIL

  • 8/16/2019 Telicom Tener

    19/104

    BSR-2011 DSR-2007Re rint 2010

    NON-DSR 

    I SANITARY INSTALLATIONS & C.P. FITTINGS 30332.53 3776.10 38310.00

    II C.I PIPES & FITTINGS 27710.06 23953.95 10000.00

    III UPVC RAIN WATER PIPES & FITTINGS 5268.15 117.00

    IV INTERNAL & EXTERNAL WATER SUPPLY WORKS 59297.73 26037.25 10125.00

    V SEWERAGE SYSTEM (UPTO S.TANK/EXISTING MH.) 126689.89 235053.65

    Total C/F To Summary 249298.36 288937.95 58435.00

    ADD COST INDEX @ 39.57% ON DSR 2007 114332.75

    Total (Headwise) 249298.36 403270.70 58435.00GRAND TOTAL

    PROPOSED CONSTRUCTION OF LVL II (4 NO.) & LVL III (5 NOS.) TRAUMA CENTRES IN THE

    STATE OF BIHAR 

    SUMMARY OF COST PLUMBING WORKS

    S.NO NAME OF SUB-HEADAMOUNT

    711004.06

    Page 19 of 104

    PLUMBING SUMMARY TCIL

  • 8/16/2019 Telicom Tener

    20/104

    S.No Ref DSR

    2007 itemDESCRIPTION UNIT QTY RATE AMOUNT

    I

    Sanitary Instatllations

    BSR 2011

    1 2.2 Providing and fixing white vitreous china pedestal type water closet (European type W.C.

    pan) with seat and lid, CP brass hinges and rubber buffers, 10 litre low level P.V.C.flushing cistern with fittings C.I/MS brackets 40mm diameter flush bend with fittings and

    clamps, overflow arrangement with specials and mosquito proof coupling of approved

    municipal design complete including painting of fittings and brackets, cutting and making

    good the walls and floors wherever required.

    2.2.3 W.C. pan with black solid plastic seat and lid each 4 2251.03 9004.12

    2 2.10A.2 Kitchen sink without drain board

    210A.2.1 610x510mm bowl depth 200 mm each 2 1669.07 3338.14

    3 2.31 Providing and fixing white vitreous china laboratory sink inlcuidng making all connections

    excluding cost of fittings.

    2.31.2 Size 600x450x200mm each 1 1573.15 1573.15

    4 2.33 Providing and fixing rubber plug for sink or wash basin each 3 9.25 27.75

    5 2.34 Providing and fixing CP brass waste for sink or wash basin

    2.34.2 40mm dia each 3 81.91 245.73

    6 2.34A Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings

    complete.

    2.34A.1 Semi rigid pipe

    a 2.34A.1.1 32 mm dia each 5 34.68 173.40

    b 2.34A.1.2 40 mm dia each 3 38.85 116.55

    BILL OF QUANTITIESINTERNAL PLUMBING WORKS

    SANITARY INSTALLATIONS & C.P FITTINGS

    Page 20 of 104

    PLUMBING WORKS TCIL

  • 8/16/2019 Telicom Tener

    21/104

    S.No

     Ref DSR

    2007 item DESCRIPTION UNIT QTY RATE AMOUNT

    7 2.36 Providing and fixing CP brass trap for wash basins and sinks

    a 2.36.1 32 mm dia each 5 108.28 541.40

    b 2.36.2 40 mm dia each 3 137.46 412.38

    8 2.42 Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved

    quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass

    screws and washers complete.

    each 4 500.06 2000.24

    CP Brass fitti ngs

    9 2.44 Providing and fixing towel rail complete with brackets fixed to wooden cleats with CP brass

    screws.

    2.44.1 CP brass towel rail with two CP brass brackets.

    2.44.1.2 600x20mm size. Each 2 190.28 380.56

    10 2.45 Providing and fixing toilet paper holder  

    a 2.45.1 CP brass each 4 112.21 448.84

    11 1.13 Providing and fixing PVC connection pipe with brass unions

    a 1.13.2 45 cm length

    1.13.2.1 15 mm nominal bore each 10 41.61 416.10

    12 1.9 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931

     a) 15 mm nominal bore each 3 204.71 614.13

    13 1.92 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS

    standards and weighing not less than 690 gms. a) 15 mm nominal bore each 5 537.32 2686.60

    14 1.93 Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved

    make conforming to IS: 8931

     a) 15 mm nominal bore each 2 204.71 409.42

    Page 21 of 104

    PLUMBING WORKS TCIL

  • 8/16/2019 Telicom Tener

    22/104

    S.No

     Ref DSR

    2007 item DESCRIPTION UNIT QTY RATE AMOUNT

    15 1.94 Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved

    quality conforming to IS:8931

     a) 15 mm nominal bore each 20 232.25 4645.00

    16 1.95 Providing and fixing C.P. brass close hole basin mixer pillar tap of approved quality and

    make, weighing not less than 1.970 kg.

     a) 15 mm nominal bore each 4 757.42 3029.68

    17 2.38A Providing & fixing Stainless steel jali (grating) with or without hole for waste pipe for  floo/nahani trap

    2.38A.1 75 mm dia weight not less than 70grams Each 2 18.97 37.94

    2.38A.2 100 mm dia weight not less than 100grams Each 10 23.14 231.40

    Total [I] 30332.53

    DSR 2007

    18 17.5 Providing and fixing white vitreous china flat back half stall urinal of size 580*380*350mm

    with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe,

    spreaders with unions and clamps (all in D.P. brass) with waste fitting as per IS : 2556, C.I.trap with outlet grating and other couplings in C.P. brass including painting of fittings and

    cutting and making good the walls and floors wherever required:

    a 17.5.1 Single half stall urinals with 5 li tre PV.C. automatic flushing cistern. each 1 3720.30 3720.30

    19 18.22 Providing and fixing C.P. brass shower rose with 15 or 20mm inlet

    18.22.2 150 mm diameter each 1 55.80 55.80

    Total [I] 3776.10

    II

    BSR 2011

    20 2.48 Providing and fixing soil, waste and vent pipes :

    2.48.1 100 mm dia.

    a 2.48.1.2 Centrifugally cast (spun) iron S&S Pipe metre 50 474.23 23711.50

    21 2.51. Providing and fixing plain bend of required degree.

    CI PIPES & FITTINGS

    Page 22 of 104

    PLUMBING WORKS TCIL

  • 8/16/2019 Telicom Tener

    23/104

    S.No

     Ref DSR

    2007 item DESCRIPTION UNIT QTY RATE AMOUNT

    2.51.1 100 mm

    a 2.51.1.2 Centrifugally cast (spun) iron S&S each 2 170.33 340.66

    22 2.72 Providing and fixing trap of self cleansing design with screwed down or hinged grating with

    or without vent arm complete, including cost of cutting and making good the walls and

    floors :

    a 2.72.1 100 mm inlet and 100 mm outlet each 10 365.79 3657.90

    Total [II] 27710.06

    DSR 2007

    23 18.10 &

    18.11

    Providing and fixing G.I. pipes complete with G.I. fittings and clamps,including cutting and

    making good the walls etc. (internal work)

    Concealed pipe including painting with anti corrosive bitumastic paint, cutting chases and

    making good the wall (for Waste Conn.from WB/Urinals/Sinks)

    18.10.4+18.40.

    4+18.78

    32 mm dia nomina bore

    (226.10+4.55+36.65) metre 10 267.30 2673.00

    bDSRno.(18.1

    0.5+18.40.5+18.78)

    40 mm dia nominal bore

    (264.05+5.20+36.65)metre 5 305.90 1529.50

    (18.10.6+18.4

    0.6+18.78)

    50 mm dia nomina bore

    (342.90+6.10+36.65) metre 5 385.65 1928.25

    24 17.50 Providing and fixing single equal plain invert branch of required degree:

    17.50.1 100x100x100mm

    17.50.1.2 Sand cast iron S&S as per IS-3989 each 1 393.20 393.20

    25 17.58 Providing lead caulked joints to sand cast iron/centrifugally cast (spun) iron pipes andfittings of diameter:

    a 17.58.1 100 mm each 55 126.50 6957.50

    26 4.5.1 Providing and laying cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone

    aggregate 20mm nominal size) 75mm in bed and around C.I Soil and waste pipe

    (embedded in the flooring / ground)

    a 100 mm dia metre 50 209.45 10472.50

    Page 23 of 104

    PLUMBING WORKS TCIL

  • 8/16/2019 Telicom Tener

    24/104

    S.No

     Ref DSR

    2007 item DESCRIPTION UNIT QTY RATE AMOUNTTotal [II] 23953.95

    III

    BSR 2011

    27

    9 Supplying, fitting and fixing PVC, SWR pipe of Prince / Supreme or any ISI make

    conforming with all scaffoldings required etc. all complete work as per specificatio &

    direction of E/I.

    12.40.2 110 mm diameter  metre 20 165.40 3308.00

    28 12.42 Supplying, fitting and fixing PVC, SWR fittings of Prince / Supreme or any ISI make

    conforming with all scaffoldings required etc. all complete work as per specificatio &

    direction of E/I.

    12.42.4 Tee with door  

    a 12.42.4.2 110mm dia each 5 150.38 751.90

    12.42.6 Plain Bend

    b 12.42.6.2 110 mm dia each 5 107.40 537.00

    12.42.6 Pipe Clip

    c 12.42.6.2 110 mm dia each 15 44.75 671.25Total [ III] 5268.15

    DSR 2007

    29 12.44 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diametre

    and weighing not less than 440 grams. each 5 23.40 117.00

    Total [III] 117.00

    IV

    BSR 2011

    30 1.2 Providing and fixing G.I. pipes complete with G.I. fittings and clamps,including cutting and

    making good the walls etc. (internal work)

    1.2.1 Exposed on wall

    a 1.2.1.2 20 mm dia nominal bore metre 5 126.94 634.70

    b 1.2.1.3 25 mm dia nominal bore metre 5 181.27 906.35

    c 1.2.1.4 32 mm dia nominal bore metre 10 228.53 2285.30

    d 1.2.1.5 40 mm dia nominal bore metre 5 256.28 1281.40

    INTERNAL & EXTERNAL WATER SUPPLY WORKS

    UPVC RAIN WATER PIPES & FITTINGS

    Page 24 of 104

    PLUMBING WORKS TCIL

  • 8/16/2019 Telicom Tener

    25/104

    S.No

     Ref DSR

    2007 item DESCRIPTION UNIT QTY RATE AMOUNT31 1.3 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling

    etc. (external work)

    a 1.3.6 50 mm dia nominal bore metre 50 310.39 15519.50

    32 1.9 Providing and fixing gun metal gate valve with C.I. wheel of approved quality(screwed end )

    a 1.9.2 20 mm nominal bore each 1 185.00 185.00

    b 1.9.3 25 mm nominal bore each 2 210.96 421.92c 1.9.4 32 mm nominal bore. each 2 288.62 577.24

    d 1.9.5 40 mm nominal bore each 2 359.20 718.40

    e 1.9.6 50 mm nominal bore each 2 533.96 1067.92

    33 1.89 Providing and placing on terrace (at all floor levels) polyethylene water storage tank of  

    approved brand and manufacture with cover and suitable locking arrangement and making

    necessary holes for inlet, outlet and overflow pipes but without fittings and the base support

    for tank Per Litre 5000 7.14 35700.00

    Total [IV] 59297.73

    DSR 2007

    34 18.5 Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes SDR 7.4 U V

    stabilized & anti - microbial fusion welded, having thermal stabil ity for hot & cold water 

    supply including all PP - R plain & brass threaded polypropylene random fittings i/c fixing

    the pipe with clamps at 1.00 m spacing. This includes the cost of cutting chases and

    making good the same including testing of joints complete as per direction of Engineer in

    charge.

    Concealed work inc luding cutting chases and making good the walls etc.,

    a 18.5.1 PN - 16 Pipe, 16 mm OD metre 65 122.65 7972.25

    b 18.5.2 PN - 16 Pipe, 20 mm OD metre 50 153.10 7655.00

    c 18.5.3  PN - 16 Pipe, 25 mm OD metre 25 201.90 5047.50

    d 18.5.4  PN - 16 Pipe, 32 mm OD metre 15 289.30 4339.50

    Page 25 of 104

    PLUMBING WORKS TCIL

  • 8/16/2019 Telicom Tener

    26/104

    S.No

     Ref DSR

    2007 item DESCRIPTION UNIT QTY RATE AMOUNT35 18.32 Constructing masonry Chamber 30X30X50 cm, inside with 75 class designation brick work

    in cement mortar 1:4 (1 Cement : 4 Coarse sand) for stop cock, with C.I. surface box

    100*100*75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix ( 1

    Cement : 2 Coarse sand : 4 graded stone aggregate 20mm nominal size) necessary

    excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate

    40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse

    sand) 12 mm thick finished with a floating coat of neat cement complete as per standard

    design:

    a 18.32.1 With F.P.S. bricks each 1 599.80 599.80

    36 18.13 Making connection of G.I. distribution branch with G.I. main of following sizes by providing

    and fixing tee, including cutting and threading in the pipe etc. complete:

    a 18.13.2 50 to 80 mm nominal bore each 1 423.20 423.20

    Total [IV] 26037.25

    V

    BSR 2011

    37 3.6 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed

    with stiff mixture of cement mortar in the proportion of 1;2 (1 cement : 2 fine sand) includingtesting of joints etc. complete:

    a 3.6.2 150 mm dia. R.C.C. pipe metre 30 196.40 5892.00

    b PBSR 200 mm dia. R.C.C. pipe metre 100 221.76 22176.00

    38 3.11 Constructing brick masonry manhole with 75 class designation briks in cement mortar 1:4 (

    1 cement : 4 coarse sand ) R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4

    graded stone aggregate 20mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4

    coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick

    with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neatcement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4

    graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement

    complete as per standard design:

    39 3.11.1 Inside size 90x80cm and 45cm deep including C.I. cover with frame (light duty)

    455x610mm internal diamensions total weight of cover and frame to be not less than 38kg

    (weight of cover 23kg and weight of frame 15 kg)

    SEWERAGE SYSTEM (UPTO S.TANK/EXISTING MH.)

    Page 26 of 104

    PLUMBING WORKS TCIL

  • 8/16/2019 Telicom Tener

    27/104

    S.No

     Ref DSR

    2007 item DESCRIPTION UNIT QTY RATE AMOUNTa 3.11.1.2 With FPS bricks each 11 5210.71 57317.81

    40 3.11.3 Inside size 120x90cm and 90cm deep including C.I. cover with frame (Medium duty)

    500mm internal diameter, total weight of cover and frame to be not less than 116kg (weight

    of cover 58kg and weight of frame 58 kg) (for Equalisation Tank)

    a 3.11.3.2 With FPS bricks each 1 9120.21 9120.21

    41 3.12 Extra for depth for Manholes

    a 3.12.1 Size 90x80cm3.12.1.2 With F.P.S bricks

    per metre 3 3430.56 10291.68

    42 3.33 Constructing brick masonry road gully chamber 110x50x77.5cm with brick of class

    designation 75 in cement mortar 1:5 (1 cement :5 coarse sand) including 500*450 mm pre-

    cast R.C.C. horizontal grating with frame and vertical grating complete as per standard

    design.

    a 3.33.1 Inside dimensions 455 x 610 mm and 45cm deep for single pipe line

    3.33.1.2 With F.P.S. bricks each 4 2093.20 8372.80

    43 3.39 Making soak pit 2.5m diameter 3.0 m deep with 40x45cm dry brick honey comb shaft with

    bricks of class designation 75 and S.W. drain pipe 100mm diameter, 1.8m long complete

    as per standard design.

    3.39.1 With F.P.S. bricks each 1 13519.39 13519.39

    126689.89

    DSR 2007

    44 19.1 Providing, laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture of cement

    mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc.

    completea 19.1.1 100 mm diameter metre 15 105.90 1588.50

    b 19.1.2 150 mm diameter metre 50 151.65 7582.50

    45 19.2 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone

    aggregate 40 mm nominal size) alround S.W. pipes including bed concrete as per standard

    design:

    Total [V]

    Page 27 of 104

    PLUMBING WORKS TCIL

  • 8/16/2019 Telicom Tener

    28/104

    S.No

     Ref DSR

    2007 item DESCRIPTION UNIT QTY RATE AMOUNTa 19.2.1 100 mm diameter S.W. pipe metre 15 331.20 4968.00

    b 19.2.2 150 mm diameter S.W. pipe metre 50 405.05 20252.50

    46 19.4 Providing and fixing square-mouth S.W. gully trap grade‘A’ complete with C.I. grating, brick

    masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the

    weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per  

    standard design

    a 19.4.2 150 x 100 mm size P type

    19.4.2.2 With Sewer bricks conforming to IS : 4885 each 6 1060.15 6360.90

    47 19.2 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone

    aggregate 40 mm nominal size) all-round SW/RCC pipes including bed concrete as per 

    standard design:

    a 19.2.2 150 mm diameter RCC pipe metre 30 405.05 12151.50

    b 19.2.3 200 mm diameter RCC pipe metre 100 472.15 47215.00

    48 2.10 Excavating trenches of required width for pipes, cables, etc including excavation for  

    sockets,and dressing of sides, ramming of bottoms, depth up to 1.5m including getting outthe excavated soil, and then returning the soil as required, in layers not exceeding 20cm in

    depth including consolidating each deposited layer by ramming, watering, etc. and

    disposing of surplus excvated soil as directed, within a lead of 50m.

    2.10.1 All kinds of soil

    a 2.10.1.2 Pipes, cables etc. exceeding 80mm dia. But not exceeding 300mm dia. metre 195 115.05 22434.75

    49 PDSR Constructing brick masonry Septic Tank of size 3.0x1.5x2.5 (with liquid depth of 1.8m for 

    cleaning interval of 3 years) cement mortar 1:4 ( 1 cement : 4 coarse sand ) R.C.C. top slab

    with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size),

    foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm

    nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse

    sand) finished with floating coat of neat cement and making channels in cement concrete

    1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished

    with a floating coat of neat cement complete as per standard design & dwg.

    Litre 9 12500.00 112500.00

    Page 28 of 104

    PLUMBING WORKS TCIL

  • 8/16/2019 Telicom Tener

    29/104

    S.No

     Ref DSR

    2007 item DESCRIPTION UNIT QTY RATE AMOUNT235053.65

    VI

    50 NS-1 Providing and fixing white vitreous counter top wash basin with specially fabricated MS/CI

    brackets painted white 32mm CP brass waste, 32mm CP cast brass bottle trap and pipe to

    wall with CP wall flange and rubber adopter for waste connection complete including

    cutting and making good the walls wherever required.

    Make: WB:Parryware or equivalent of Hindware or Cera . Each 4 2400.00 9600.00

    51 NS-2 Providing and Fixing C.P. brass Ablution health faucet assembly with 1.2 m long braided

    PVC hose with mounting bracket fixed on wall complete.[FOR EWC] Each 3 500.00 1500.00

    52 NS-3 Providing and fixing CP brass copper inlet connection of size 15mm nominal bore 45cm

    length with brass unions. Each 10 261.00 2610.00

    53 NS-4 Providing & Fixing CP brass liquid soap container fixed to the wall with PVC rubber plug

    with C.P brass screw complete each Each 1 900.00 900.00

    54NS-5 Supplying & Fixing of CP soap tray fixed to the wall with PVC rubber plug with CP brass

    screws Each 2 770.00 1540.00

    55 NS-6 Providing and fixing hinged stainless steel construction anti-cockroach trap with grating

    including fixing to the floor trap complete in all respects.

    a) a). 100mm dia Each 2 485.00 970.00

    56 NS-7 Providing and fixing C.P. brass Two-way angle valve for EWC points & for fixing AblutionHealth Fauct of approved quality conforming to IS:8931. 15 mm nominal bore

    Each 3 1230.00 3690.00

    57

    NS-8 Providing and Fixing, testing and commissioning of vertical / horizontal storage type hot

    water heater fixed to wall with anchor bolts & nuts, 20mm CP brass cock and 20mm non

    return valve complete including making connection with 15 mm dia CP connecting pipe on

    Inlet and Outlet, suitable length of power cable and 15A plugh.

    Total [V]

    NON-SCHEDULED ITEMS

    SANITARY INSTALLATIONS & C.P FITTINGS

    Page 29 of 104

    PLUMBING WORKS TCIL

  • 8/16/2019 Telicom Tener

    30/104

    S.No

     Ref DSR

    2007 item DESCRIPTION UNIT QTY RATE AMOUNTa) Capacity 15 liters Each 1 4500.00 4500.00

    b) Capacity 25 liters Each 2 6500.00 13000.00

    Total [VI] 38310.00

    VII

    58 NS-9 Providing and fixing G.I Inlet fitting with maximum 3 inlets 32, 40 or 50 mm size fabricated

    from 100 mm dia G.I pipes(approx. length=150mm to 300mm) and welded G.I sockets,

    fixed to CI trap with lead caulked joint and set in cement concrete as per standard drawing

    including cost of Bitumastic paint complete. Each 10 950 9500.0059 NS-10 Providing and fixing floor drain with 65mm x 50mm GI Elbow with cement mortar,

    compelete in all respect Each 2 250 500.00

    10000.00

    VIII

    60 NS-11 Providing and fixing insulation to hot water pipes with Kaiflex or equivalent insulation as per manufacturer specifications

    a) 18mm dia(nominal bore) and 6 mm thick Metre 30 150.00 4500.00

    b) 25mm dia(nominal bore) and 6 mm thick Metre 25 225.00 5625.00

    10125.00

    CI PIPES & FITTINGS

    Total [VII]

    INTERNAL WATER SUPPLY WORKS

    Total [VIII]

    Page 30 of 104

    PLUMBING WORKS TCIL

  • 8/16/2019 Telicom Tener

    31/104

    BSR 2011 NON-DSR  

    1 ELECTRICAL PART-I 392101.00 367518.00

    2 ELECTRICAL PART-II 0.00 126873.00

    3 ELECTRICAL PART-III 160860.00 648956.00

    Total C/F To Summary 552961.00 1143347.00

    GRAND TOTAL

    PROPOSED CONSTRUCTION OF LVL II (4 NO.) & LVL III (5 NOS.) TRAUMA CENTRES INTHE STATE OF BIHAR 

    SUMMARY OF COST ELECTRICAL WORKS

    S.NO NAME OF SUB-HEADAMOUNT

    1696308.00

    Page 31 of 104

    ELECTRICAL SUMMARY TCIL

  • 8/16/2019 Telicom Tener

    32/104

    Rs. Rs.

    I

    1 Point wiring in PVC conduit, with modular type switch :-Wiring for l ight point /fan point/exhaust fan point/call bell point with 1.5 sqmm FR PVC

    insulated copper conductor single core cable in surface / recessed PVC conduit, with

    modular switch, modular plate,, suitable GI box etc. as required.

    BSR No. 1.3.3 Group C 124 Points 564.00 69936.00

    2 S/F Light plug point with all accessories :-

    BSR No. 1.31 Supplying and fixing suitable size of GI box with modular plate and cover in front on surface

    or in recess, including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6

    amps modular type switch, connection, painting etc. as required. (For light plugs to be used

    in non residential buildings).

    56 Each 237.00 13272.00

    3 S/F power plug point with all accessories :-

    BSR No. 1.32 Supplying and fixing suitable size of GI box with modular plate and cover in front on surface

    or in recess, including providing and fixing 6 pin 20/16 amps modular socket outlet and

    20/16 amps modular switch, connection, painting etc. as required.

    32 Each 313.00 10016.00

    4 S/F Modular type electronic fan regulator :-

    BSR No. 1.25 Supply and fixing of stepped type electronic fan regulator on the existing modular plateswitch box including connections but excluding modular plate etc. as required.

    22 Each 321.00 7062.00

    6 S/F Modular Boxes, Base & Cover plate :-

    POINT WIRING AND SUB MAIN WIRING

    BILL OF QUANTITIESELECTRICAL WORKS PART-I

    S.No. Ref BSR

     2011 item

     DESCRIPTION QTY UNIT RATE

    (in Rs)

     AMOUNT

    (in Rs)

    Page 32 of 104

    ELECTRICAL PART-I TCIL

  • 8/16/2019 Telicom Tener

    33/104

    S.No. Ref BSR DESCRIPTION QTY UNIT RATE AMOUNTSupplying and fixing following size / modules, GI box along with modular base & cover plate

    for modular switches in recess etc as required

    BSR No. 1.27.1 1 or 2 Module (75 mm x 75 mm) 22 Each 115 2530.00

    7 Circuit/Sub main wiring in PVC conduit :-

    Wiring for  Submain/Circuit wiring along with earth wire with the following sizes of PVC

    insulated, copper conductor single core cable in surface/ recessed PVC conduit as

    required.

    BSR No. 1.7.2 2X2.5 sq. mm + 1X2.5 sq. mm Earth wire. 600 Mtrs 125.00 75000.00

    BSR No. 1.7.3 2X4.0 sq. mm + 1X4.0 sq. mm Earth wire. 150 Mtrs 169.00 25350.00

    BSR No. 1.7.4 2X6.0 sq. mm + 1X6.0 sq. mm Earth wire. 125 Mtrs 244.00 30500.00

    BSR No. 1.7.10 4X4.0 sq. mm + 2X4.0 sq. mm Earth wire. 50 Mtrs 260.00 13000.00

    BSR No. 1.7.11 4X6.0 sq. mm + 2X6.0 sq. mm Earth wire. 25 Mtrs 387.00 9675.00

    BSR No. 1.7.12 4X10.0 sq. mm + 2X10.0 sq. mm Earth wire. 20 Mtrs 592.00 11840.00

    S/F PVC Condu it8 Supplying and fixing of following sizes of PVC conduit along with accessories in

    surface/recess including cutting the wall and making good the same in case of recessed

    conduit as required.

    BSR No. 1.21.2 25 mm 50 Mtrs 52 2600.00

    BSR No. 1.5 Power plug wiring in PVC Conduit :

    9 Wiring for light / Power plug with 2x4 sqmm FR PVC insulated copper conductor  

    single core cable in surface / recessed PVC conduit, along with 1 no. 4sqmm FR PVC

    insulated copper conductor single core cable for loop earthing as required.

    100 Mtrs 170 17000.00

    287781.00

    (II)

    S/F prewired TP MCB DB :

    TOTAL [I]

    DISTRIBUTION BOARD'S, MCB's AND MCCB's

    Page 33 of 104

    ELECTRICAL PART-I TCIL

  • 8/16/2019 Telicom Tener

    34/104

    S.No. Ref BSR DESCRIPTION QTY UNIT RATE AMOUNT10 Supplying and fixing following way, three pole and neutral,prewired, sheet steel, MCB

    distribution board, 415 volts,on surface /recess, complete with loose wire box,terminal

    blocks,duly prewired with suitable size FR PVC insulated copper busbar, neutral linkr, earth

    bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted

    including earthing etc. as required (But without MCB / RCCB / Isolators).

    BSR No. 2.9.4 4 way (4 + 12), Double door, horizontal type 1 Each 2024.0 2024.00

    BSR No. 2.9.5 6 way (4 + 18), Double door, horizontal type 2 Each 2529.0 5058.00BSR No. 2.9.6 8 way (4 + 24), Double door, horizontal type 2 Each 3078.0 6156.00

    S/F TPN RCCB :

    11 Supplying and fixing following rating, T,P&N, (three phase and neutral) 415 volts, residual

    current circuit breaker  (RCCB), having a sensivity current upto 300 miliampere in the

    existing MCB DB complete with connections,testing and commissioning etc. as required :

    BSR No. 2.18.2 40 Amps 2 Each 2311 4622.00

    BSR No. 2.18.3 63 Amps 3 Each 2691 8073.00

    S/F FP MCB isolator :

    12 Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB

    complete with connections, testing and commissioning etc.

    BSR No. 2.16.1 40 Amps 2 Each 675 1350.00

    BSR No. 2.16.2 63 Amps 3 Each 703 2109.00

    BSR No. 2.16.3 80/100 Amps 1 Each 907 907.00

    S/F "C" series, SP MCB :

    13 Supplying and fixing following rating, 240 volts `C' series, miniature circuit breaker  (MCB)

    suitable for inductive load of following poles in the existing MCB DB complete with

    connections, testing and commissioning etc. as required.

    BSR No. 2.12.1 Single Pole (2 amp to 32 Amp) 96 Each 156 14976.00

    BSR No. 2.12.3 Single pole and Neutral ( 2 Amp to 32 Amp) 5 Each 440 2200.00

    BSR No. 2.12.5 Triple Pole (10 Amp to 63 Amp 4 Each 927 3708.00

    Page 34 of 104

    ELECTRICAL PART-I TCIL

  • 8/16/2019 Telicom Tener

    35/104

    S.No. Ref BSR DESCRIPTION QTY UNIT RATE AMOUNT

    S/F vertical type TP MCB DB:

    14 Supplying, and fixing following way, three pole and neutral, sheet steel, MCB distribution

    board, 415V, on surface / recess, complete with tinned copper busbar, neutral busbar, earth

    bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted

    including earthing etc. as required (but without MCB/RCCB/Isolator)

    BSR No. 2.10.1 4 way (8+12), single door, vertical type 1 Each 3339.0 3339.00

    54522.00

    (III)

    S/F modular type switch/socket :

    15 Supplying and fixing following modular switch / socket on the existing modular plate & switch

    box including connections but excluding modular plate etc as required.

    BSR No. 1.24.6 Telephone Socket outlet 9 Each 77 693.00

    16 S/F Modular Boxes, Base & Cover plate :-

    Supplying and fixing following size / modules, GI box along with modular base & cover plate

    for modular switches in recess etc as required

    BSR No. 1.27.1 1 or 2 Module (75 mm x 75 mm) 9 Each 115 1035.00

    Telephone wiring in existing conduit :

    17 Supply and drawing following pair, 0.5 sq.mm. FR PVC insulated copper conductor,

    unarmoured telephone cable in the existing surface / recessed conduit as required.

    BSR No. 1.16.2 2 Pair 200 Each 20 4000.00

    S/F PVC Condu it

    TOTAL [II]

    TELEPHONE AND DATA SYSTEM

    Page 35 of 104

    ELECTRICAL PART-I TCIL

  • 8/16/2019 Telicom Tener

    36/104

    S.No. Ref BSR DESCRIPTION QTY UNIT RATE AMOUNT18 Supplying and fixing of following sizes of PVC conduit along with accessories in

    surface/recess including cutting the wall and making good the same in case of recessed

    conduit as required.

    BSR No. 1.21.2 25 mm 200 Mtrs 52 10400.00

    16128.00

    (IV)

    Salt/coke for pipe earth electrode :

    19 BSR No. 3.4 Extra for using salt and coke for pipe earth electrode as required. 2 Set. 2421.00 4842.00

    G.I earth pipe electrode :

    20 BSR No. 3.1 Supplying and Earthing with GI earth pipe, 4.5mtr long, 40mm dia including accessories

    and providing masonary enclosure with cover plate having locking arrangement etc, (but

    without charcoal / coke and salt ) as required.

    2 Set. 1910 3820.00

    S/L 25 mm x 5 mm G.I earth strip in ground:

    21 BSR No. 3.11 Supplying and Laying of 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth

    electrode, including soldering etc. as required.

    50 Mtrs 52.00 2600.00

    P/L 25 mm x 5 mm G.I earth strip in pipe :

    22 BSR No. 3.14 Providing and fixing of 25mm x 5mm G.I strip in 40mm dia G.I Pipe from earth electrode as

    required.

    50 Mtrs 295.00 14750.00

    26012.00

    (V)

    ITC Fluorescent fitting directly on surface :

    23 BSR No. 1.40 Installation, testing and commissioning of  prew ired , f lou rescen t f it ti ng / compact

    fluorescent fitt ing of all types, complete with all accessories and tubes etc. directly on

    ceiling / wall, including connection with 1.5 sq. mm. PVC insulated, copper conductor, single

    core cable etc. as required.

    84 Each 36 3024.00

    S/F call bell / buzzer :

    EARTHING SYSTEM

    TOTAL [IV]

    INSTALLATION OF LIGHT FIXTURES

    TOTAL [III]

    Page 36 of 104

    ELECTRICAL PART-I TCIL

  • 8/16/2019 Telicom Tener

    37/104

    S.No. Ref BSR DESCRIPTION QTY UNIT RATE AMOUNT24 BSR No. 1.36 Supplying and fixing of call bell / buzzer suitable for D.C/A.C single phase, 230 V, complete

    as required.

    11 Each 60 660.00

    S/F Ding Dong Call Bell :

    25 BSR No. 1 .37 Supplying and fixing ding dong call bell suitable for D.C/A.C single phase, 230 V, complete

    as required.

    11 Each 106 1166.00

    4850.00

    (VI)

    ITC ceiling fan :

    26 BSR No. 1.43 Installation, testing and commissioning of  cei ling fan including wiring the down rod of 

    standard length (upto 30 cm.) with 1.5 sq. mm. FR PVC insulated, copper conductor, single

    core cable etc. as required.

    22 Each 44 968.00

    ITC exhaust fan upto 450 mm sweep :

    27 BSR No. 1.47 Installation of exhaust fan upto 450 mm sweep in the existing opening, including making the

    hole to suit the size of the above fan, making good the damage, connections, testing,

    commissioning etc. as required.

    7 Each 192 1344.00

    Fixing louvers / shutters for exhaust fan :

    28 BSR No. 1.49 Extra for fixing the louvers / shutters complete with frame fro exhaust fans of all sizes. 7 Each 50 350.00

    2662.00

    (VII)P/F M.V danger notice plate :

    29 BSR No. 2.20 Providing and fixing M.V. danger not ice p late of 200mmx150mm made of mild steel,

    atleast 2mm thick and vitreous enamelled white on both sides and with inscription single red

    colour on front side as required.

    2 Each 73 146.00

    146.00

    MISCELLANEOUS ITEMS

    TOTAL [VII]

    TOTAL [V]

    INSTALLATION OF FANS AND EXHAUST FANS

    TOTAL [VI]

    Page 37 of 104

    ELECTRICAL PART-I TCIL

  • 8/16/2019 Telicom Tener

    38/104

    S.No. Ref BSR DESCRIPTION QTY UNIT RATE AMOUNT

    (VIII)

    30 Supplying, fixing, connecting & testing of Telephone Tag Block krone type in a suitable

    size 1.6 mm thick dust and vermin proof Sheet steel enclosure duly painted by synthetic

    enamel over anti corrosive primer, lockable and hinged cover with provision for cable

    through glands complete in all respects.

    NS 50 pair krone 1 Nos. 1359 1359.00

    31 Supplying, laying, testing and commissioning of following size anealed tinned copper  

    conductor PVC insulated and sheathed armoured copper telephone cables with suitable

    clamps, saddles and including making terminal joints complete as required.

    NS 50 pair 20 Metre 637 12740.00

    32 N.S Supply and Erecting modular type computer jack RJ 45 ISI mark approved make with

    mounting plate and box with wiring connections complete.

    11 Nos. 643 7073.00

    33 N.S Supplying & installing UTP networking Cat-6 cable suitable for LAN/WAN computer net

    working as per catalog no. DC6CAUTP4P3X.

    250 Metre 26 6500.00

    34 N.S Supply, installation, testing and commissioning of CAT 6 giga speed patch cord 2m or  

    equivalent feet and factory terminal at both ends as per catalog no. DC6PCURJO2GYM.

    11 Nos. 268 2948.00

    35 N.S Supply and installation of 24 port CAT 6 patch panel modular type complete as required as

    per catalog no. DC6PP24UKY1U.

    1 Nos. 7686 7686.00

    36 N.S Supply, installation, testing and commissioning of CAT 6 giga speed patch cord 1.2m or  

    equivalent feet and factory terminal at both ends as per catalog no.DC6PCURJ01GYM.

    11 Nos. 251 2761.00

    37 N.S Supply, installation, testing and commissioning of wall mounted data rack 12 U with glass

    door hardware, cable manager, cooling fans power points etc.

    1 Nos. 8176 8176.00

    NON-DSR ITEMS

    Page 38 of 104

    ELECTRICAL PART-I TCIL

  • 8/16/2019 Telicom Tener

    39/104

    S.No. Ref BSR DESCRIPTION QTY UNIT RATE AMOUNT

    38 N.S Supply, laying and end terminations including connections of 6 core outside plant cable

    corrugated steel tape armoured, loose tube, gel filled 50/125 micron OM cube fiber multi

    mode armoured fibre optical cable in wall/floor/ground complete as required in one segment

    with fiber connector as per catalog no. DFCA051GSTO6.

    15 Mtrs 200 3000.00

    39 N.S Supply, installation, testing and commissioning of 24 Port 10/100 Edge Switch. 1 Nos. 80000 80000.00

    132243.00

    (IX)

    S/L armoured cable :

    40 Supplying and Laying of following sizes and core PVC/XLPE insulated PVC sheated, heavy

    duty, armoured, electrical cable with aluminium conductor for working voltage upto and

    including 1100 volts.(conforms to IS:1554,part-1).

    N.S 3.5 x 70 sq.mm. Aluminium Cable 20 Mtrs. 606.00 12120.00

    N.S 3.5 x 35 sq.mm. Aluminium Cable 20 Mtrs. 349.00 6980.00

    41 Supplying and making end terminations with brass compression glands and aluminium lugs

    for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 

    1.1 KV grade as required.

    N.S 3.5 x 70 sq.mm. Aluminium Cable 4 Each 200 800.00

    N.S 3.5 x 35 sq.mm. Aluminium Cable 4 Each 150 600.00

    20500.00

    (X)S/F box type fitting with lamp.

    42 N.S Supplying and fixing mounting rail / box type fitting complete with copper ballast 4'x40 watt

    fluorescent lamp etc. directly on ceiling / wall, including connection with 1.5 sqmm FR PVC

    insulated copper conductor cable etc. as required.

    Single 15 Nos. 487 7305.00

    SUPPLY OF LIGHT FIXTURES

    TOTAL [VIII]

    NON-DSR

    TOTAL [IX]

    Page 39 of 104

    ELECTRICAL PART-I TCIL

  • 8/16/2019 Telicom Tener

    40/104

    S.No. Ref BSR DESCRIPTION QTY UNIT RATE AMOUNT43 N.S Supply of surface/wall mounting 1x 18 watt CFL satin finish diffuser , low loss magnetic

    gear, IP23. with lamp complete in all respects.

    29 Nos. 1874 54346.00

    44 N.S Supply of surface mounting 2 x 18 watt CFL satin finish diffuser, low loss magnetic gear,

    IP23. with lamp complete in all respects.

    25 Nos. 3065 76625.00

    45 N.S Supply of surface mounting 2 x 36 watt T8 Lamp, low loss magnetic gear (PF>.9) with lamp

    complete in all respects.

    10 Nos. 1450 14500.00

    46 N.S Supply of surface/wall mounting 1 x 18 watt mirror light T8 Lamp, low loss magnetic gear  with lamp complete in all respects. 5 Nos. 547 2735.00

    155511.00

    (XI)

    47 N.S Supply of Ceiling Fan of 1200mm sweep complete erected in position with all accessories. 22 Nos. 1675 36850.00

    48 N.S Supplying of Exhaust Fan Heavy duty 230V A.C 50 cycles 375 mm 1400 RPM complete

    erected in position with all accessories.

    7 Nos. 3202 22414.00

    59264.00

    GRAND TOTAL OF DSR [I+II+III+IV+V+VI+VII] 392101.00

    GRAND TOTAL OF NON DSR [VIII+IX+X+XI] 367518.00

    TOTAL [X]

    SUPPLY OF FANS AND EXHAUST FANS

    TOTAL [XI]

    Page 40 of 104

    ELECTRICAL PART-I TCIL

  • 8/16/2019 Telicom Tener

    41/104

    S.No. BSR 2011 DESCRIPTION QTY UNIT RATE

    (in Rs)

     AMOUNT

    (in Rs)

    (I)

    1

    Supply, laying, jointing, testing and commissioning of ISI marked (IS : 14930, part 2)

    H.D.P.E. (DWC) Double wall Corrugated pipe for cable laying having corrugation on

    outer wall and plain smooth surface at inner side including transportation upto the site,

     jointing, providing and fixing all fittings i.e. sockets, couplers, reducers, end caps etc to

    complete the works in all respects.

    N.S 50 mm. ID / 65 mm OD 40 Nos. 88 3520.00

    2 Supplying and laying of following sizes of RCC hume pipes NP2 grade in road crossings

    and below paved areas laid and jointed complete with collars as required including

    excavation, road cutting and making good the damages etc including Cement concrete in

    foundations filling and mass concrete.1:4:8 (1cement 4 coarse sand and 8 grit 40 mm and

    below.( below Hume pipes)

    N.S 100 mm. dia 20 Nos. 209.00 4180.00

    7700.00

    (II)

    3 Design, manufacturing, testing at works, supply, installation, testing and commissioning

    of floor mounting free standing totally enclosed indoor cubical extensible

    compartmentalized front operational vertical dust and vermin proof D.G Isolator Panel

    fabricated out of 2 mm thick CRCA sheet steel provided with hinged detachable lockable

    and front and back openable comparmentalised individual chamber doors including

    strengthening and stiffening complete as requiredand as per specifications. The panel

    shall be powder coated after proper treatment with 8 tank process and shall be providedwith following components :-

    Incoming:

    1 No. 160 amp FP MCCB of minimum 20 KA breaking capacity.

    Metering:

    BILL OF QUANTITIES

    ELECTRICAL WORKS PART-II

    HDPE & HUME PIPE :

    TOTAL [I]

    ELECTRICAL PANEL:

    Page 41 of 104

    ELECTRICAL PART-II TCIL

  • 8/16/2019 Telicom Tener

    42/104

    S.No. BSR 2011 DESCRIPTION QTY UNIT RATE

    (in Rs)

     AMOUNT

    (in Rs)The Indicating panel of the incomer shall be provided with the following :

    One (1) No. (0-500V) 96 x 96 Sq.mm voltmeter and voltage selector switch

    3 Nos. phase indicating lamps; backed up with 2 A MCB.

    Bus Bar:

    200A, TPN aluminium bus bar of suitable length with colour coded sleeves.

    Outgoings:

    2 Nos. 63 A FP MCB of 10 KA breaking capacity.1 Nos. 63 A FP MCCB of 20 KA breaking capacity.

    N.S 2 Nos. 40 A FP MCB, of 10 KA breaking capacity. 1 Nos. 69733 69733.00

    69733.00

    (III)

    4 N.S Supplying and fixing of Post top lantern with 400 mm prismatic clear globe suitable for 36

    watt CFL including lamp with 6.0 mtr. Long casted aluminium pole with base and all

    accessories with suitable size of junction box and connectors.

    Note : Foundat ion work fo r Post top Po le i s not i nvol ve in Elec tr ical works i t w ill

    come on Civil work.

    2 Nos. 19890 39780.00

    S/L armoured cable :

    5 Supplying and Laying of following sizes and core PVC/XLPE insulated PVC sheated,

    heavy duty, armoured, electrical cable with aluminium conductor for working voltage upto

    and including 1100 volts.(conforms to IS:1554,part-1).

    N.S 2.0 x 10 sq.mm. Aluminium Cable 60 Mtrs. 153.0 9180.00

    6 Supplying and making end terminations with brass compression glands and aluminium

    lugs for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade as required.

    N.S 2.0 x 10 sq.mm. Aluminium Cable 4 Each 120 480.00

    49440.00

    GRAND TOTAL OF BSR

    GRAND TOTAL OF NON-BSR 126873.00

    EXTERNAL LIGHTING & CABLING :

    TOTAL [III]

    TOTAL [II]

    Page 42 of 104

    ELECTRICAL PART-II TCIL

  • 8/16/2019 Telicom Tener

    43/104

    S.No.BSR 2011 DESCRIPTION QTY UNIT RATE

    (in Rs)

     AMOUNT

    (in Rs)

    (I)

    S/F PVC Condu it

    1

    Supplying and fixing of following sizes of PVC conduit along with accessories in surface/recess

    including cutting the wall and making good the same in case of recessed conduit as required.

    BSR No. 1.21.2 25 mm 150 Mtrs 52 7800.00

    TOTAL [I] 7800.00

    (II)

    Salt/coke for plate earth electrode :

    2 BSR No. 3.8 Extra for using salt and coke for G.I or copper plate earth electrode as required. 8 Set. 3286.00 26288.00

    G.I earth plate electrode :3 BSR No. 3.5 Earthing with G.I earth plate 600mm x 600mm x 6mm thick including accessories, and providing

    masonary enclosure with cover plate having locking arrangement and watering pipe etc. (but

    with out charcoal or coke and salt) as required.

    4 Set 2255.00 9020.00

    Copper earth plate electrode :

    4 BSR No. 3.6 Earthing with Copper earth plate 600mm x 600mm x 6mm thick including accessories, and

    providing masonary enclosure with cover plate having locking arrangement and watering pipe

    etc. (but with out charcoal or coke and salt) as required.

    4 Set 5578 22312.00

    5 BSR No. 3.11 Supplying and Laying of 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth

    electrode, including soldering etc. as required.

    80 Mtrs 52.00 4160.00

    P/F 25mm x 5mm G.I earth strip in pipe :

    BILL OF QUANTITIES

    ELECTRICAL WORKS PART-III

    PVC CONDUIT :

    EARTHING SYSTEM

    Page 43 of 104

    ELECTRICAL-III TCIL

  • 8/16/2019 Telicom Tener

    44/104

    S.No.BSR 2011 DESCRIPTION QTY UNIT RATE

    (in Rs)

     AMOUNT

    (in Rs)6 BSR No. 3.14 Providing and fixing of 25mm x 5mm G.I strip in 40mm dia G.I Pipe from earth electrode as

    required.

    80 Mtrs 295.00 23600.00

    P/F 25mm x 5mm copper earth strip in pipe :

    7 BSR No. 3.13 Providing and fixing of 25mm x 5mm copper strip in 40mm dia G.I Pipe from earth electrode as

    required.

    80 Mtrs 846.00 67680.00

    TOTAL [II] 153060.00

    (III)

    8 N.S Supply, installation, testing & commissioning of 1 No. 30 KVA / 24 KW UPS in stand alone

    configuration, UPS should be DSP(Digital Signal Processing), controlled true on line double

    conversion 3 phase input & 3 phase output UPS system with each UPS module having IGBT

    based Rectifier. THD(I) shall be less than 5% at 100% linear load. input power factor should be

    0.99 across the load spectrum DSP (Digital Signal Processing) technology invertor fully digital

    direct control, sealed maintainence free batteries.(26AH X 32 Nos.) for UPS for total 10 minutes

    back up time. external 30KVA/24KW three phase output isolation transformer. also including

    Batteries, Batteries Rack, cable from UPS to Batteries, MCCB, Connectors and including all

    accessories.(85% Loading shall be considered.)

    1 Nos. 541650 541650.00

    TOTAL [I II] 541650.00

    (IV)

    Supplying, installation testing and commissioning of Conventional Type Fire Detection

    and Alarm System

    9 N.S Supplying, installation testing and commissioning of Conventional, Microprocessor Fire alarmand Detection Control Panel-1 Zone.

    1 Nos. 14501 14501.00

    10 N.S Supply, Installation, Testing and Commisssiong of Manual Call Point. 1 Nos. 870 870.00

    11 N.S Supply, Installation, Testing and Commisssiong of Hooter. 1 Nos. 1160 1160.00

    UPS SYSTEM

    FIRE ALARM AND DETECTION SYSTEM

    Page 44 of 104

    ELECTRICAL-III TCIL

  • 8/16/2019 Telicom Tener

    45/104

    S.No.BSR 2011 DESCRIPTION QTY UNIT RATE

    (in Rs)

     AMOUNT

    (in Rs)12 N.S Supply, Installation, Testing and Commisssiong of End Resistance Box. 1 Nos. 181 181.00

    13 N.S Supply, Installation, Testing and Commisssiong of Smoke Detector. 8 Nos. 943 7544.00

    14 N.S Supplying, and Laying of 2 core 1.5 sqmm flexible sheated circular cable with electrolytic grade

    annealed bare copper conductor 1100 V grade.

    150 Nos. 54 8100.00

    TOTAL [ IV] 32356.00

    (VI)

    15 N.S Supplying and erecting,testing and commissioning ampl if ier 150 W for PA system suitable tooperate on 230 Volts. AC/12 Volt DC supply.

    1 Nos. 16000 16000.00

    16 N.S Supplying, Erecting, Testing and Commissioning speaker 10 watts complete with allaccessories.

    4 Nos. 2500 10000.00

    17 N.S Supplying, Erecting, Testing and Commissioning microphone . 1 Nos. 5750 5750.00

    18 N.S Supplying, and Erecting, stand for microphone. 1 Nos. 2300 2300.00

    19 N.S Supplying, erecting, testing to 2 core sheilded speaker and microphone cable.. 75 Nos. 40 3000.00

    S/F PVC Condu it

    Supplying and fixing of following sizes of PVC conduit along with accessories in surface/recess

    including cutting the wall and making good the same in case of recessed conduit as required.

    20 N.S 25 mm 75 Mtrs 52 3900.00

      TOTAL (V) 40950.00

    (VII)

    PUBLIC ADDRESSABLE SYSTEM

    LIGHTING FIXTURES (CLEAN ROOM LIGHT FIXTURES)

    Page 45 of 104

    ELECTRICAL-III TCIL

  • 8/16/2019 Telicom Tener

    46/104

    S.No.BSR 2011 DESCRIPTION QTY UNIT RATE

    (in Rs)

     AMOUNT

    (in Rs)21 N.S Supply, installation, testing and commissioning of Surface mounting T8, 2X36 Watt G13, PC

    Housing, PC diffuser, SS Toggles with T8 Lamp and integral HF(THD

  • 8/16/2019 Telicom Tener

    47/104

    BSR-2011 DSR-2007 (Reprint 2010) NON-DSR 

    Sub-Head -I Down Comer System 68,485.00 

    Sub-Head -II Hand Appliances 11,585.00 

    Sub-Head -III Fire Pumps & Ancillaries 137,700.00 

    Total C/F To Summary 217770.00

    GRAND TOTAL

    PROPOSED CONSTRUCTION OF LVL II (4 NOS.) & LVL III (5 NOS.) TRAUMA CENTRES IN THESTATE OF BIHAR

    SUMMARY OF COST FIRE FIGHTING/PROTECTION SYSTEM

    S.NO NAME OF SUB-HEADAMOUNT

    217770.00

    Page 47 of 104

    FIRE FIGHTINGPROTECTION SUMMARY TCIL

  • 8/16/2019 Telicom Tener

    48/104

    S.No NSR Description Qty. Unit Rate Amount

    Sub-Head - I - Down Comer System

    1 NSR S/L/J/T of following sizes of Heavy class (C class) mild steel pipe, flanges and fitting such as

    bends, tees, reducers, rubber insertions and galvanized nuts and bolts 'heavy class '

    confirming to IS:1239-1974 part -I and amendment I/c fixing the pipe on wall / ceiling with

    suitable MS strip/clamps/bracket and painting with one coat of primer and two or more coats

    of synthetic enamel paint etc. complete as required.(Internal works).

    a) 25mm dia 5 metre 230.00 1,150.00 

    b) 50mm dia 5 metre 460.00  2,300.00 

    c) 65mm dia 5 metre 600.00  3,000.00 

    d) 80mm dia 5 metre 735.00 3,675.00 

    2 NSR Providing and fixing internal fire hydrant comprising of SS Fire Hydrant Valve 80mm inlet

    with single headed with single outlet with control and fitted with 63mm dia instantaneousfemale coupling on the outlet complete with orifice flange as required, blank cap and chain

    locations as per drawings (inlet flanges to I.S 5290-1977 class C)

    1 each 6,500.00  6,500.00 

    3 NSR Providing and fixing first aid fire hose reel equipment confirming to IS : 884-1969 with upto

    date amendments finished with post office red spray paint and complete with following as

    required :

    a) 20mm dia 36.5 metres long hose tubing of approved make confirming to IS : 5132-1969 withupto date amendments.

    b) Swinging type hose guide fixing bracket assembly

    c) 25mm dia gate valve

    d) 6mm outlet SS nozzle with shut off valve as required 1 each 8,500.00  8,500.00 

    Bill of Quantities (BOQ)

    Fire Fighting / Protection System

    Page 48 of 104

    FIRE FIGHTING TCIL

  • 8/16/2019 Telicom Tener

    49/104

    S.No NSR Description Qty. Unit Rate Amount

    4 NSR Providing and fixing 63mm dia 15m long Reinforced Rubber lined (RRL) woven jacketedhose tested to bursting pressure 32 Kg/sqcm including gunmetal male and female

    instantaneous type coupling approved by fire authority, machine would with G.I wire

    complete in all respects. Hose shall conform to I.S 636 Type II and coupling to I.S 903-1985

    with ISI certification (Two per hydrant station)

    2 each 4,500.00  9,000.00 

    5 NSR Providing and fixing fire hose cabinet fabricated from 16 gauge MS sheet of fully welded

    construction with hinged double front door with locking arrangement and partially glazed

    with 4mm thick glass, stove enameled fire red finish with "fire hose" written on front suitableto house 2x15m two length of canvas hose with couplings, branch pipe. One fireman's axe,

    first aid fire hose reel and hydrant outlet.

    a) Size 2100 x 900 x 600mm (HxBxD) 1 each 7,600.00  7,600.00 

    6 NSR Providing and fixing standard short size gunmetal branch pipe with gunmetal nozzle 16mm

    dia outlet with standard male instantaneous spring lock type 63mm dia coupling. Branch

    pipe and nozzle shall confirm to IS : 903-1985.

    1 each 1,950.00  1,950.00 

    7 NSR Providing and fixing standard fireman's axe with heavy insulated rubber handle complete. 1 each 1,500.00  1,500.00 

    8 NSR Providing and fixing gunmetal collecting head with 63mm dia instantaneous type inlet and

    150mm dia flanged outlet with built-in check valve for fire brigade connection to

    undergro