TEST & MEASURING INSTRUMENTS

TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

TEST & MEASURING INSTRUMENTS

岩通総合表1表4 00.9.29 11:17 AM ページ 1

Page 2: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

1

1987 The SS-6521 introduced as the world’s highest bandwidthportable oscilloscope.

1989 Japan’s first logic analyzer (SL-4640/4641) with a high-speed 400-MHz clock introduced (the fastest at that time).

1992 Japan’s first logic analyzer (SL-4650/4651) with a high-speed 1GHz clock (the fastest at that time) introduced.Super storage scope with a 400 MHz bandwidth and asuper high speed of 10 div/ns (TS-8421/8422) introduced.Dynamic IWATSU exhibition held (at 7 locations in Japan)

1993 The exhibition and business conference center opened inTokyo metropolitan area (Shinjuku).Agreement with Lecroy Japan for sales partnership.

1994 40th anniversary of the introduction of oscilloscopes.4 analog oscilloscope models — the SS-7800 series— (20 MHz – 100 MHz) introduced.

1995 Fukushima Iwatsu Co. Ltd. — a major electronicmeasuring instrument manufacturing plant — certifiedISO9002 certificate (July). ISO9002 certificate (August).SD-1000 ATM tester and SD-70 PHS field tester forcommunication systems introduced.

1998 TS-8500 analog oscilloscope introduced.

HISTORY OF IWATSU TEST & MEASUREMENT

1954 IWATSU’s first oscilloscope, the first made in Japan,delivered to the Technical Institute of the Self-DefenseAgency.

1960 IWATSU’s first electronic counter and data loggerintroduced.

1961 IWATSU’s first CRT (cathode ray tube) designed andmanufactured.

1962 IWATSU started to design and manufacture the proprietaryIC (integrated circuit).

1969 IWATSU started to design and manufacture the Hybrid IC.

1970 The SS-4100 oscilloscope designed with IC technologyand introduced to the market.

1971 The VOAC-77 introduced as the first Japanese-madehandheld digital multimeter.

1972 IWATSU introduced the SM-1300 data processinginstrument.

1974 The LS-6211 introduced as the first Japanese-made logicanalyzer.

1975 The world’s fastest digitizer DM-901 featuring a 100MS/sclock rate introduced to the market.

1979 The MA-1008 introduced as the first Japanese-madeemulator.

1980 The world’s fastest storage oscilloscope TS-8121 featuringa 3,000 cm/µs writing speed introduced.

1984 The optical test and measurement instruments SA-9601and the SA-9602 introduced.IWATSU awarded by the Science and Technology Agencyfor developing the innovative scan converter tube.

Targeting tomorrow’s electronicsAt IWATSU, our focus is always on the future. With therelentless pace of development in the electronicsindustry, success demands innovation, creativity, andan unwavering commitment to research anddevelopment. Building on our solid base ofaccumulated basic research, we are expanding ourcutting-edge R&D with high technology bothdomestically and overseas.In addition to communication equipment such astelephones, we manufacture a wide range of electronicequipment and systems — from electronic measuringinstruments such as oscilloscopes to electronic offset-plate making machines for printing and a variety ofbusiness machines.

Headquarters office

p01-p26 00.9.28 2:06 PM ページ 1

Page 3: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

2

1. Oscilloscopes 6

2. Logic Analyzers 27

3. B-H Analyzers 30

4. Digital Multimeters 41

5. Universal Counters 59

6. Signal Generators 63

7. Training Instruments 71

8. Probes 78

9. Accessories 84

INDEXESDS-8607A

DS-8608A

DS-8617

DS-8710

DS-8812

FG-330

FG-350

HV-P30

HV-P60

ITF-01

ITF-02

ITF-03

ITF-05

ITF-06

ITF-07

ITF-201

ITF-202

ITF-203

ITF-204

ITF-205

MT-45

MT-555A

PG-230

PS-26

SC-003

SC-005

SC-0107

SC-011

SC-0113

SC-0116

SC-302A

SC-303A

SC-304A

SC-305A

SC-306

SC-340

SC-7205

SC-7206

SC-7207

SG-4101

SG-4102

SG-4112

SK-2101A

SL-4122

SL-4640A/4641A

SL-4650/4651

SS-240

SS-7802A

SS-7804

SS-7804P

SS-7810

SS-7811

SS-7811P

SS-7821

SS-7825

SS-7840

SS-7840H

SS-7840P

SY-8101

SY-8217

SY-8232

TS-8500

VOAC-7411

VOAC-7412

VOAC-7413

VOAC-7510

VOAC-7512

VOAC-7513

60 MHz/20 MS/s DSO......................................................... 21

100 MHz/20 MS/s DSO....................................................... 21

100 MHz/100 MS/s DSO..................................................... 23

100 MHz/20 MS/s DSO....................................................... 20

100 MHz/500 MS/s DSO..................................................... 25

0.01 Hz - 1 MHz/function generator .................................... 68

0.1 Hz - 10 MHz/function generator .................................... 67

DC 30 kV/high voltage probe .............................................. 83

DC 60 kV/high voltage probe .............................................. 83

Circuit training kit................................................................. 72

Logic circuit training kit........................................................ 73

Pulse circuit training kit ....................................................... 73

Semiconductor training kit................................................... 74

Counter circuit training kit.................................................... 74

Arithmetic circuit training kit ................................................ 75

Optical transmission training kit .......................................... 75

Operational amplifier training kit.......................................... 76

AD/DA converter training kit................................................ 76

Frequency modulator/demodulator training kit.................... 77

Laser displacement measurement training kit..................... 77

Scope wagon ...................................................................... 84

Scope wagon ...................................................................... 84

Pulse generator................................................................... 69

Probe power supply ............................................................ 83

High-voltage probe.............................................................. 58

4-wire ohms test cable ........................................................ 58

Sheath type thermocouple .................................................. 58

Clamp-on current probe ...................................................... 58

Measuring leads.................................................................. 58

Surface thermocouple ......................................................... 58

Printer unit........................................................................... 55

GP-IB unit............................................................................ 56

BCD output unit................................................................... 56

D/A converter ...................................................................... 57

Battery unit .......................................................................... 57

Oscilloscope calibrator ........................................................ 70

Universal Counter 230 MHz................................................ 62

Universal Counter 2 GHz .................................................... 61

Universal Counter 3 GHz .................................................... 60

0.1 Hz - 1 MHz/function generator ...................................... 66

10 mHz - 15 MHz/function generator .................................. 65

10 mHz - 15 MHz/function generator .................................. 64

Scope wagon ...................................................................... 84

100 MHz/logic analyzer....................................................... 27

400 MHz/logic analyzer............................................... 27

1 GHz/logic analyzer ................................................... 27

Current probe...................................................................... 83

20 MHz/analog oscilloscope ............................................... 11

40 MHz/analog oscilloscope ............................................... 11

40 MHz/programmable oscilloscope................................... 17

100 MHz/analog oscilloscope ............................................. 11

100 MHz/analog oscilloscope ............................................ 11

40 MHz/programmable oscilloscope................................... 17

200 MHz/analog oscilloscope ............................................. 11

250 MHz/analog oscilloscope ............................................. 9

400 MHz/analog oscilloscope ............................................. 9

470 MHz/analog oscilloscope ............................................. 9

400 MHz/programmable oscilloscope................................. 17

B-H analyzer ....................................................................... 35

B-H analyzer ....................................................................... 33

B-H analyzer ....................................................................... 31

500 MHz Analog storage oscilloscope................................ 7

40999, 4-1/2 digits/digital multimeter .................................. 53

40999, 4-1/2 digits/digital multimeter .................................. 51

40999, 4-1/2 digits/digital multimeter .................................. 49

409999, 5-1/2 digits/digital multimeter ................................ 47

409999, 5-1/2 digits/digital multimeter ................................ 45

409999, 5-1/2 digits/digital multimeter ................................ 43

p01-p26 00.9.28 2:06 PM ページ 2

Page 4: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

3

Quality control

IWATSU believes that customers useIWATSU instruments with confidencebecause of their high quality. In order tomaintain that quality, IWATSUinstruments are thoroughly tested atevery stage of the production process —from designing to manufacturing — toensure that they meet IWATSU qualitystandards.

TRACEABILITY

A major reason why IWATSU instrumentshave such a high reputation is that theyare fully compliant with the Japanesenational standards set by theElectrotechnical Laboratory. Accordingly,they also comply with internationalstandards. The chart below illustrates IWATSUtraceability.

n IWATSU TRACEABILITY CHART

ISO 9000

IWATSU's SS-7840 — SS-7802 analogoscilloscopes and other instruments aremanufactured under a quality assurancesystem in a certified ISO9002 factory,operated by Fukushima Iwatsu Co, Ltd.,a subsidiary company of IWATSU.

QUALITY CONTROL / TRACEABILITY

ELECTRO TECHNICAL LABORATORY

B.I.P.M.(BUREAU INTERNATIONAL DES POIDS ET MESURE)

NIST (USA) NPL (ENGLAND) KRISS (KOREA) COMMUNICATION RESEARCH LABORATORY

JAPAN ELECTRIC METERS INSPECTION CORPORATION JAPAN QUALITY ASSURANCE ORGANIZATION

NATIONAL STANDARD

STANDARD DECADE TRANSFORMER

AC DC COMPARATOR

VOLTAGE STANDARD

STANDARD DC CELL

DC CALIBRATOR

RESISTANCE METER

STANDARD RESISTOR

STANDARD CAPACITOR

STANDARD INDUCTOR

DIGITAL THERMOMETER

STANDARD OPTICAL POWER METER

STANDARD RECEIVER

RF POWER METER

VLF/LF RECEIVER

STANDARD SIGNAL

AC VOLTAGE GENERATOR

DC VOLTAGE GENERATOR

DIGITAL VOLT METER

STANDARD RESISTOR

RESISTANCE TRANSFER LCR METER

MICROWAVE FREQUENCY COUNTER

AC DEFERENTIAL VOLT METER

STANDARD SHUNT

RESISTANCE METER

AC VOLTAGE CURRENT DC VOLTAGE CURRENT RESISTANCE CAPACITANCE INDUCTANCE TEMPERATURE OPTICAL RF POWER FREQUENCY

IWATSU REFERENCE & WORKING STANDARD

p01-p26 00.9.28 2:06 PM ページ 3

Page 5: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

4

1. Frequency bandwidth1-1. What is frequency bandwidth?Iwatsu’s lineup includes 20, 40, 100, 200, 250, 400, and 500 MHz bandwidth oscilloscopes.Selecting the most suitable bandwidth:For example, a 100 MHz oscilloscope displays a 100 MHz 1V (p-p) input signal on the screen with an amplitude of approximately 0.7V (-3 dB). Fig. 1 The displayed amplitude depends on the input signal frequency. The higher the frequency input, the smaller the amplitude display.The relationship between frequency and 0.7 times amplitude can be expressed as

f=1/ (2 πR C)Then what about a 33 MHz input signal?The ratio between 33 MHz to 100 MHz is equal to 3 times.

A = 31+32

310

= = 0.949

Tr = 3.52+102 = 10.59ns

Tr = A2+B2+C2+D2 ···· N2

A = R1+R2

In this case, a 5% error is included.Normalized expression for formula (1): R = RATIO A = Amplitude

The displayed pulse has a rise time about 5% slower than the original 10 ns.Normalized expression for Formula (3): A is scope, B is pulse, C is amplifier, D is cable.

Fig 4 shows the relationship between rise time ratio vs. displayed error.For example, if scope rise time and pulse rise time have the same value, then theTr ratio is 1.In this case, a 41% error is included.If the ratio is 3, the error is only 5%.

1-2. The rise time of an oscilloscopeFormula (2) shows the relationship between the rise time (10% - 90%) Fig. 2 and the frequency bandwidth.

f = 0.35 / Tr (2)

With Formula (2), the rise time of a 100 MHz oscilloscope is calculated as 3.5 ns.The value 3.5 ns is the displayed rise time on the 100 MHz scope screen when 0 ns rise time pulse isapplied to input terminal. Fig. 3How much rise time (Tr) is displayed on the 100 MHz oscilloscope screen when a 10 ns rise time pulse isapplied to input terminal?The calculation is as follows.

(1)

Fig. 1

Fig. 2

Fig. 3

(3)

Fig. 4

Use this rule of thumb when selecting an oscilloscopeThe oscilloscope bandwidth should be at least 3 times the test circuit bandwidth or the rise time should be less than 1/3 of the test circuitswitching time.

Oscilloscope bandwidth > 3 x Circuit bandwidthOscilloscope rise time < 1/3 Circuit switching time

2. ANALOG and DSO (Digital Storage Oscilloscope)There are basically two types of scope — analog and digital storage.This section explains the differences between these scopes so you can better understand which type is best suited to your needs. Iwatsu offersboth types.

ANALOGREAL-TIME Does not have storage capability

SS-78 seriesSTORAGE Stores waveforms on the screen of a special CRT

TS-8500DIGITALStores waveforms as digital data in a semiconductor memory. Uses an A/D converter.

DS-8812, DS-8710, 8706

Iwatsu offers DSO models with a real-time scope: DS-8617, DS-8608A, 8607A

90%

10%

PULSE GENSCOPE 100 MHz

Tr Ratio

Err

or (

%)

Tr

How to select the oscilloscope that best suits your needs

p01-p26 00.9.28 2:06 PM ページ 4

Page 6: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

5

Differences between Analog and DSO are follows.DSO Advantages2-1 Single shot captureAnalog oscilloscope needs trace recording camera.Advanced skill required for capturing.DSO can store a single shot waveform in memory.

2-2 Pre-triggerAnalog oscilloscope can display a waveform only about 20 ns before the trigger point.DSO can display a waveform up to the memory length.

2-3 Low speed motion (low frequency) recordingAnalog Spot beam moves from left to right and disappears.Digital Stable display remains after waveform disappears (same as recorder).

2-4 Analysis and data outDSO can calculate the captured data and output the data to a printer or PC.

Analog Advantages2-5 Easy operation with unknown signals.Even if you have no idea what type of signal is being sent to your checking circuit, you can easily obtain the waveform with an analog scope.With DSO you have to know the signal frequency, amplitude and shape, then set the DSO to the proper range to prevent a aliasing errors.

2-6 No aliasingAliasing occurs when the input signal frequency is higher thanhalf the sampling frequency.Signal frequency (1 MHz) > 1/2 sampling frequency (2 MHz) Aliasing shows a lower frequency waveform with a waveformshape similar to the original waveform.Fig. 5 shows an aliasing waveform.The original waveform is sampled by a sampling pulse. Sampleddata (Dots) are connected to make an aliasing waveform.To avoid aliasing with a DSO, the sweep rate has to be setproperly.An analog scope, on the other hand, can display the waveformwithout aliasing regardless of the sweep rate.

2-7 Fast display update rateA DSO normally captures data at a maximum rate of about 100 times/sec.Fig. 6An analog scope, however, can display a signal waveform at rates of 200kto 1 million times/sec max.With a sweep rate range above 1 ms/div., a DSO may fail to capture anunknown anomalous signal.With a very fast sweep rate of 1 µs/div. or higher, a common analog scopecan capture unusual anomalous signals.In some cases, the waveform may not be visible or may be too dark tosee.In this case, an analog storage scope such as the TS-8500 can be used toview the waveform. The TS-8500 can capture a single shot waveform at500 ps/div.

2-8 Brightness informationAnalog scopes display a signal histogram for brightness information.Frequent signals are displayed in the bright portion and infrequent signalsin the dark portion.A DSO displays any waveform with the same brightness points.Recently, some DSOs have been introduced capable of displaying brightness in the same way as an analog scope.

2-9 Low costFor example, the price of an analog scope capable of displaying a 100 MHz signal at 2 nsec/div. is less than half that for a DSO with higher V, Hresolution.

Fig. 5

Fig. 6

Conclusion

COMPARISON POINTS ANALOG DSO

1. Price vs. Features Low High

2. Aliasing Yes No

3. Easy operation User friendly, Familiar Not intuitive

4. Real time display Yes No

5. Vertical resolution Infinite (S/N ratio) A/DC 8 bit

6. Sweep resolution Infinite Sample rate

7. Waveform update rate 200k display/sec 100 display/secat 100 nsec/div.

8. Brightness information Yes No

Original

SamplingPulse

Anomalous Signal

SIGNAL

ANALOG

SWEEP

HOLDOFF TIME

DSO

SWEEP

DEAD TIME LONG DEAD TIME Approx. 10 ms

Alias

p01-p26 00.9.28 2:06 PM ページ 5

Page 7: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

6

Specification TS-8500 SS-7840H SS-7840 SS-7825 SS-7821 SS-7811 SS-7810 SS-7804 SS-7802A

Display Type TFT Color LCD CRT CRT CRT CRT CRT CRT CRT CRT

Size 5.5" 8x10 cm 6" 8x10 cm 6" 8x10 cm 6" 8x10 cm 6" 8x10 cm 6" 8x10 cm 6" 8x10 cm 6" 8x10 cm 6" 8x10 cm

Accel. Voltage 20 kV 20 kV 20 kV 16 kV 16 kV 16 kV 16 kV 2 kV

Scale Illumination Yes Yes Yes Yes Yes Yes Yes Yes —

V Deflection ADD ALT CHOP Yes Yes Yes Yes Yes Yes Yes Yes Yes

Signal Delay >20 ns >20 ns >20 ns >20 ns >30 ns >30 ns >30 ns >30 ns —

CH 1•2 Range 2 mV ~ 5 V/div 2 mV ~ 5 V/div 2 mV ~ 5 V/div 2 mV ~ 5 V/div 2 mV ~ 5 V/div 2 mV ~ 5 V/div 2 mV ~ 5 V/div 2 mV ~ 5 V/div 2 mV ~ 5 V/div

Accuracy 2% 2% 2% 2% 2% 2% 2% 2% 2%

Variable ~12.5V/div ~12.5V/div ~12.5V/div ~12.5V/div ~12.5V/div ~12.5V/div ~12.5V/div ~12.5V/div ~12.5V/div

Band Width 500 MHz 470 MHz 400 MHz 250 MHz 200 MHz 100 MHz 100 MHz 40 MHz 20 MHz

Coupling AC DC GND AC DC GND AC DC GND AC DC GND AC DC GND AC DC GND AC DC GND AC DC GND AC DC GND

Input R 1MΩ ±1.5% 1MΩ ±1.5% 1MΩ ±1.5% 1MΩ ±1.5% 1MΩ ±1.5% 1MΩ ±1.5% 1MΩ ±1.5% 1MΩ ±1.5% 1MΩ ±1.5%

Input C 16 pF ± 2 pF 16 pF ± 2 pF 16 pF ± 2 pF 16 pF ± 2 pF 20 pF ±2 pF 20 pF ±2 pF 20 pF ±2 pF 20 pF ±2 pF 25 pF ± 2 pF

50 Ω Input 50 Ω ±1% 50 Ω ±1% 50 Ω ±1% 50 Ω ±1% — — — — —

Max. Voltage 400 Vp-p 400 Vp-p 400 Vp-p 400 Vp-p 400 Vp-p 400 Vp-p 400 Vp-p 400 Vp-p 400 Vp-p

B/W Limit 100 M, 20 MHz 100 M, 20 MHz 100 M, 20 MHz 100 M, 20 MHz 20 MHz 20 MHz 20 MHz — —

Probe Sense Yes Yes Yes Yes Yes Yes Yes Yes Yes

CH2 Invert Yes Yes Yes Yes Yes Yes Yes Yes Yes

TV Clamp Yes Yes Yes Yes — — — — —

Offset Yes Yes Yes Yes — — — — —

CH1, CH2 Skew Yes Yes Yes Yes — — — — —

CH3 Range 100, 500 mV 100, 500 mV 100, 500 mV 100, 500 mV 50, 100, 500 mV 50, 100, 500 mV 50, 100, 500 mV — —

Accuracy 3% 3% 3% 3% 2% 2% 2% — —

Band Width 500 MHz 400 MHz 400 MHz 250 MHz 200 MHz 100 MHz 100 MHz — —

Coupling AC DC AC DC AC DC AC DC AC DC AC DC AC DC — —

Input R 1 M ± 1.5% 1 M ± 1.5% 1 M ± 1.5% 1 M ± 1.5% 1 M ± 1.5% 1 M ± 1.5% 1 M ± 1.5% — —

Input C 16 pF ± 3 pF 16 pF ± 3 pF 16 pF ± 3 pF 16 pF ± 3 pF 20 pF ± 3 pF 20 pF ± 3 pF 20 pF ± 3 pF — —

Probe Sense Yes Yes Yes Yes Yes Yes Yes — —

CH4 Same as CH3 Same as CH3 Same as CH3 Same as CH3 — — — — —

Trigger Source CH1, 2, 3, 4, CH1, 2, 3, 4, CH1, 2, 3, 4, CH1, 2, 3, 4, V, CH1, 2, 3, V, CH1, 2, 3, V, CH1, 2, 3, V, CH1, 2, Ext. V, CH1, 2, Ext.Line Line Line Line Line Line Line Line Line

Coupling AC DC HF-R LF-R Yes Yes Yes Yes Yes Yes Yes Yes Yes

Event Count, Burst Yes Yes Yes Yes — — — — —

TV Trig HDTV Yes Yes Yes Yes — — — — —

NTSC, PAL (SECAM) Yes Yes Yes Yes Yes Yes Yes Yes Yes

Line number select Yes Yes Yes Yes Yes Yes Yes Yes Yes

Sweep A Sweep Fastest Sweep Rate 5 ns/div 5 ns/div 5 ns/div 10 ns/div 10 ns/div 20 ns/div 20 ns/div 100 ns/div 200 ns/div

Slowest Sweep Rate 500 ms/div 500 ms/div 500 ms/div 500 ms/div 500 ms/div 500 ms/div 500 ms/div 500 ms/div 500 ms/div

Accuracy 2% 2% 2% 2% 2% 2% 2% 2% 2%

Hold off Yes Yes Yes Yes Yes Yes Yes Yes Yes

B Sweep Trigger Delay Yes Yes Yes Yes Yes Yes Yes — —

Fastest Sweep Rate 5 ns/div 5 ns/div 5 ns/div 10 ns/div 10 ns/div 20 ns/div 20 ns/div — —

Slowest Sweep Rate 20 ms/div 500 ms/div 500 ms/div 20 ms/div 5 ms/div 5 ms/div 5 ms/div — —

Accuracy 2% 2% 2% 2% 2% 2% 2% — —

Trace Separation Yes Yes Yes Yes Yes Yes Yes — —

Dual Delay Yes — — — — — — — —

ALT Sweep Yes Yes Yes Yes Yes Yes Yes — —

B Ends A Yes Yes Yes Yes Yes Yes Yes — —

Magnifier 10 TIMES Yes Yes Yes Yes Yes Yes Yes Yes Yes

Max. Sweep Rate 500 ps/div 500 ps/div 500 ps/div 1 ns/div 1 ns/div 2 ns/div 2 ns/div 10 ns/div 20 ns/div

X-Y X Range CH1 CH1 CH1 CH1 CH1 CH1 CH1 CH1 CH1

Bandwidth 10 MHz 2 MHz 2 MHz 2 MHz 2 MHz 2 MHz 2 MHz 2 MHz 1 MHz

Y Range CH1, 2, 3, 4, Add CH1, 2, 3, 4, Add CH1, 2, 3, 4, Add CH1, 2, 3, 4, Add CH1, 2, 3, Add CH1, 2, 3, Add CH1, 2, 3, Add CH1, 2, Add CH1, 2, Add

Phase 3˚ 5 MHz 3˚ 200 kHz 3˚ 200 kHz 3˚ 200 kHz 3˚ 200 kHz 3˚ 200 kHz 3˚ 200 kHz 3˚ 50 kHz 3˚ 20 kHz

Cursor ∆V, ∆t, 1/∆t Yes Yes Yes Yes Yes Yes Yes Yes Yes

Counter Frequency Range 500 MHz 400 MHz 400 MHz 250 MHz 200 MHz 100 MHz 100 MHz 40 MHz 20 MHz

Accuracy 5 Digits 0.0 1% 5 Digits 0.0 1% 5 Digits 0.0 1% 5 Digits 0.0 1% 5 Digits 0.0 1% 5 Digits 0.0 1% 5 Digits 0.0 1% 5 Digits 0.0 1% 5 Digits 0.0 1%

Auto Setup V, H Posi, V, H Range, Trigger Yes Yes Yes Yes Yes Yes Yes — —

Save/recall 256 256 256 256 32 32 — — —

Z Axis Bandwidth 5 MHz 5 MHz 5 MHz 5 MHz OPTION OPTION OPTION OPTION OPTION

Signal Out CH2 Out Bandwidth 200 MHz 200 MHz 200 MHz 200 MHz OPTION OPTION OPTION OPTION OPTION

Video Out (NTSC) Yes — — — — — — — —

CAL Out 1 kHz 0.6V Yes Yes Yes Yes Yes Yes Yes Yes Yes

Probe power Yes Yes Yes Yes — — — — —

Power AC Range 100 V – 240 V Yes Yes Yes Yes — — — — —

100 V – 120 V/200 V – 240 V — — — — Yes Yes Yes Yes —

100, 110 – 120, 220, 230 V – — — — — — — — — Yes

240 V

Frequency 50 Hz – 60 Hz 50 Hz – 400 Hz 50 Hz – 400 Hz 50 Hz – 400 Hz 50 Hz – 400 Hz 50 Hz – 400 Hz 50 Hz – 400 Hz 50 Hz – 400 Hz 50 Hz – 60 Hz

Consumption 140 VA 120 VA 120 VA 120 VA 110 VA 110 VA 110 VA 110 VA 60 VA

Dimensions W x H x L (mm) 320 x 160 x 420 320 x 160 x 420 320 x 160 x 420 320 x 160 x 420 272 x 152 x 410 272 x 152 x 410 272 x 152 x 410 272 x 152 x 410 272 x 152 x 410

Weight 8.5 kg 8.5 kg 8.5 kg 8.5 kg 7.5 kg 7.5 kg 7.5 kg 7.5 kg 8.5 kg

Accessories Power cord, Manual (1) Yes Yes Yes Yes Yes Yes Yes Yes Yes

Fuse Yes Yes Yes Yes Yes Yes Yes Yes —

Two Probes with probe sense Yes Yes Yes Yes Yes Yes Yes — —

Two Probes without probe sense — — — — — — — Yes Yes

Panel cover (1) Yes Yes Yes Yes Yes Yes Yes Yes Yes

Option Z axis input and CH2 out SS-505 SS-502 SS-502 SS-501 SS-500

ANALOG OSCILLOSCOPE SELECTION GUIDE

p01-p26 00.9.28 2:06 PM ページ 6

Page 8: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

7

Analog Storage Oscilloscope TS-8500

TS-8500DC – 500 MHz, 4 CH

m Ultra-high speed storage capabilityNewly-developed scan converter tube allows capture of single shotphenomena even at the highest sweep rate.For instance, it can display the leading edge of a 6.25 div amplitude,1 nsec rise-time pulse or any part of a 3.2 div amplitude, 500 MHzsine wave in a single shot sweep.

m Maximum writing speed for all rangesand guaranteed wide bandwidth fromDC to 500 MHz

Unlike a digital storage oscilloscope, the TS-8500’s waveform displaycapability and frequency bandwidth are not dependent on the sweeprange. As a result, aliasing does not occur.

m “Burn-free” because waveforms arestored by the CCD

m NTSC video outputConnect the TS-8500 to a video printer for quick, easy printouts. Youcan also connect this scope directly to a personal computer via avideo board, for waveform processing.

m Persistence function allows waveformsto be overwritten

Ultra-High Writing Speed AnalogStorage OscilloscopeThe TS-8500 ultra-high writing speed analog storageoscilloscope allows precise observation of high-speedsingle shot phenomena and sporadic noise (glitch). A newly-developed scan converter tube makes itpossible for this scope to capture noise which appearsin repetitive signals as well as high-speed single shotphenomena.Featuring the same high levels of operability and basicperformance as our popular 470 MHz/400 MHz analogoscilloscopes (SS-7840H/SS-7840), this scope requiresno special training or operation, making it an idealsolution to the common problems encountered everyday in electronics engineering.

m Time base dual delay functionTwo independent delay time settings are provided for B sweeps,allowing delay magnification of two signals.

m Examples of observed waveforms

Constellation waveformShows phase and jitter of a 256QAM signal. This is one of themodem evaluation methods. Jitter can be checked by the sizeof the spot waveform while the phase can be evaluated by theshape of a square formed by four spots.

Read-write signal for hard disk driver byusing B-trigger

p01-p26 00.9.28 2:06 PM ページ 7

Page 9: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

8

Specificationsn Display 5.5-inch, TFT color LCD (240 x 320 dots)n Storage CRT CCD scan converter tube (430 x 600 dots)n Fastest writing speed 5 div/nsn Persistence time Variable to infinityn Vertical deflection system (Y axis)Vertical mode CH1, CH2, CH3, CH4, ADD (CH1 + CH2),

ALT, CHOP CH1, CH2 Sensitivity

Range 2 mV/div – 5 V/div, 11-step (1-2-5)Variable adjuster 2 mV/div – 12.5 V/div, continuously variableAccuracy ±2%

Frequency bandwidth Bandwidth DC – 500 MHz, -3 dBBand limit DC – 20 MHz or DC – 100 MHz

Note: The lower limit frequency is 10 Hz with ACcoupling.

Rise time Approx. 700 psNote: Use the following formula.

350Tr = [ns]

Bandwidth [MHz]

Signal delay time 20 ns or more (delay time on the screen) Input coupling AC, DC, GND Input RC 1 MΩ ± 1.5% // 16 pF ± 2 pF,

50 Ω input: 50 Ω ±1%Max. input voltage

1 MΩ input ±400 V max. (DC + AC peak)50 Ω input 5 Vrms max.

VSWR 1.35 or less (with DC – 500 MHz, 50 Ω)Offset voltage

Vertical range Offset voltage2 mV/div – 50 mV/div ±1 V0.1 V/div – 0.5 V/div ±10 V

1 V/div – 5 V/div ±100 V

Frequency AmplitudeDC – 10 MHz 0.4 div

10 MHz – 100 MHz 1.0 div100 MHz – 500 MHz 2.0 div

Frequency AmplitudeDC – 10 MHz 0.4 div

10 MHz – 100 MHz 1.0 div100 MHz – 250 MHz 2.0 div

Polarity switching CH2 onlyProbe sense 1:1, 10:1, 100:1 CH3, CH4Sensitivity

Range 100 mV/div, 500 mV/divAccuracy ±2%

Frequency bandwidth DC – 500 MHz, -3 dBInput coupling AC, DCInput RC 1 MΩ, ±1.5%//16 pF ±3 pFMax. input voltage ±400 V max. (DC + AC peak)Probe sense 1:1, 10:1, 100:1n Triggering A triggeringSource CH1, CH2, CH3, CH4, LINECoupling AC, DC, HF-REJ, LF-REJSlope +, –Sensitivity

n Horizontal deflection system (X axis)Display (HORIZ DISPLAY) A, ALT, B, X-Y A sweep Sweep mode AUTO, NORMAL, SINGLESweep time

Max. sweep time 500 ps/divRange 5 ns/div – 500 ms/div, (1-2-5 step) switchable in

25 stepsHold-off time Variable

B sweep Delay TRIG’D DELAY

RUNS AFTER DELAYSweep time

Max. sweep time 500 ps/divRange 5 ns/div – 20 ms/div, (1-2-5 step) switchable in

21 stepsAccuracy ±2%

Delay jitter 1/20000 at 1 ms/div for A sweep, 500 ns/div forB sweep

Dual delay Possible Sweep magnificationMagnifier X10n X-Y operation X axis (CH1)Sensitivity

Range Same as CH1Accuracy ±2%Frequency response DC – 10 MHz, -3 dB

Y axis CH1, CH2, CH3, CH4, ADDPhase difference Within 3˚ (DC – 5 MHz)n CAL (calibration signal)Waveform Square-waveFrequency 1 kHz, ±0.1%Duty ratio 49% – 51%Output voltage 0.6 V, ±1%n CH2 OUTOutput voltage 20 mV/div, ±30% (50 Ω load)Frequency bandwidth 200 MHz, -3 dB (50 Ω load)Output resistance 50 Ω, ±20%n Probe powerConnector number 2Voltage +12 V, –12 Vn VIDEO OUT NTSC, 1 Vp-p ±0.3 Vn Z AXIS INIntensity modulation voltage 0.5 Vp-p or morePolarity With positive voltage, dark; with negative

voltage, brightFrequency range DC – 5 MHzInput resistance 5 kΩ ±20%Max. input voltage ±40 V max.n Cursor measurement Time difference (∆t), voltage difference (∆V)n CounterDisplay digits 5-digit (A trigger source)Accuracy ±0.01%Frequency measurement range 2 Hz – 500 MHzn Save/Recall Max. 256 panel settingsBackup time Approx. 27,000H (at 25˚C)n Power supplyVoltage range AC 100 V – 240 VFrequency range 50/60 HzPower consumption Max. 140 VAn Weight and dimensionsWeight Approx. 8.5 kg (without accessories)Dimensions Approx. 320W x 160H x 420L mmn Environmental conditions Performance guaranteed 10˚C – 35˚C

temperatureOperating range

Temperature 0°C – 40°CHumidity 90% RH (0˚C – 40˚C)

Storage rangeTemperature -20°C – 70°CHumidity 80% RH (-20˚C – 70˚C)

n Accessories Power cord (x1), probe (SS-101R) (x2), panelcover (1), fuse (x2), operation manual (x1),accessory bag (x1)

TV triggerFormat NTSC, PAL (SECAM), HDTVTrigger mode TV-V (ODD, EVEN, BOTH), TV-HTV line ODD, EVEN, BOTH, selectable

NTSC 1 H – 525 HPAL (SECAM) 1 H – 625 HHDTV 1 H – 1125 H

TV clampClamp position Back porch levelClamp level Within ±1 divSignal amplitude 1.5 div – 8 div

Event triggerCount mode

Count range 1 – 65535Max. count frequency 50 MHz

Burst modeBurst time range 0.15 µs – 9.99 s

AUTO SETUPInput channel CH1, CH2Frequency range 50 Hz – 100 MHz

B triggeringSource CH1, CH2, CH3, CH4Coupling AC, DC, HF-REJ, LF-REJSlope +, –Sensitivity

p01-p26 00.9.28 2:06 PM ページ 8

Page 10: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

9

SS-7840HDC – 470 MHz, 4 CH, 10 tracesSS-7840DC – 400 MHz, 4 CH, 10 tracesSS-7825DC – 250 MHz, 4 CH, 10 traces

Analog Oscilloscopes SS-7840H/SS-7840/SS-7825

m DC – 470 MHz, 4 CH, 10 tracesFour channels of up to 470 MHz are available with CH1 and CH2boasting the widest frequency range.

SS-7840H DC – 470 MHz (-3 dB) at 5 mv ~ 50 mV/div

DC – 440 MHz (-3 dB) at 2 mV, 100 mV ~ 5 V/div All other features and specifications are same as SS-7840.

m Input offset functionSuitable for the observation of small amplitude signals, the DC inputoffset function features an offset equivalent to ±500 div. max. that canbe applied to CH1 or CH2.

m Quick auto setup (CH1, CH2)Pressing the button automatically displays the optimum range for theinput waveform on the CRT (for CH1 and CH2).

m TV/HDTV triggerTV triggering is available for NTSC, PAL (SECAM) and HDTV. Field(EVEN/ODD/BOTH) and line select functions are provided.

m Counter measurement functionBuilt-in 5-digit counter displays frequencies of up to 400 MHz.(6 digit: Factory option)

m Save/recall of up to 256 settingsTurning the FUNCTION knob recalls the panel setup. Up to 256settings can be stored in memory.

m Power supply for FET probe

m Pedestal clamp function (CH1 or CH2)

• Save/recall of up to 256 panel settings• Quick auto setup• Full NTSC, PAL (SECAM), HDTV TV

triggering with field and line• 2 mV/div high sensitivity and 500 ps/div

sweep rate (SS-7840, H)• 5-digits frequency counter• Cursor function• 100 mV, 500 mV/div CH3 ranges • Probe power for FET or current probe• Offset function• TV pedestal clamp function

p01-p26 00.9.28 2:06 PM ページ 9

Page 11: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

10

Specificationsn CRTShape 6-inch rectangular. internal graticule, meshless

CRT with scale illuminationEffective area 8 x 10 div (1 div = 10 mm)Accelerating voltage Approx. 20 kVn Vertical deflection system (Y axis)Vertical mode CH1, CH2, CH3, CH4 ADD (CH1 + CH2) ALT,

CHOP (555 kHz ± 1%) CH1, CH2 Sensitivity

Range 2 mV/div – 5 V/div(1-2-5 sequence in 11 steps)Variable adjuster 2 mV/div – 12.5 V/div. continuously variableAccuracy ±2%

Frequency bandwidth Bandwidth DC – 470 MHz -3 dB (SS-7840H)

DC – 400 MHz -3 dB (SS-7840)DC – 250 MHz -3 dB (SS-7825)Note: The lower limit frequency is 10 Hz with ACcoupling

Bandwidth limiter DC –20 MHz, 100 MHz (SS-7840/7840H)DC –20 MHz (SS-7825)

Rise time Approx. 745 ps (SS-7840H)Approx. 875 ps (SS-7840)Approx. 1.4 ns (SS-7825)Note: Calculated from the following formula

350Tr = [ns]

Bandwidth [MHz]

Signal delay time 20 ns or more (on the screen) Input coupling AC, DC, GND Input RC 1 MΩ ± 1.5% // 16 pF ± 2 pF,

50 Ω input: 50 Ω ± 1%Max. input voltage

1 MΩ input ± 400 V (DC + AC peak) 50 Ω input 5 Vrms

VSWR 1.35 or less (with DC – 400 MHz,DC – 250 MHzfor SS-7825)

Offset voltageVertical range Offset voltage

2 mV/div – 50 mV/div ±1 V0.1 V/div – 0.5 V/div ±10 V

1 V/div – 5 V/div ±100 V

Polarity switching CH2 onlyProbe sense 1:1, 10:1, 100:1 CH3, CH4Sensitivity

Range 100 mV/div, 500 mV/divAccuracy ± 3%

Frequency bandwidth DC – 400 MHz, -3 dB (SS-7840)DC – 250 MHz, -3 dB (SS-7825)

Input coupling AC, DCInput RC 1 MΩ, ±1.5%//16 pF ±3 pFMax. input voltage ±400 V max. (DC + AC peak)Probe sense 1:1, 10:1, 100:1n Triggering A triggeringTrigger mode EDGE, EVENT, TVSource CH1, CH2, CH3, CH4, LINECoupling AC, DC, HF-REJ, LF-REJSlope +, –Sensitivity

Event trigger COUNT, BURST Count range 1 – 65535Max. count frequency 50 MHzBurst time range 0.15 µs – 9.99 s

AUTO SETUPInput channel CH1, CH2Frequency range 50 Hz – 100 MHzn Horizontal deflection system (X axis)Display (HORIZ DISPLAY) A, ALT, B, X-Y A sweep Sweep mode AUTO, NORMAL, SINGLESweep rate 5 ns/div – 500 ms/div (1-2-5 sequence in 25

steps) (SS-7840) 10 ns/div – 500 ms/div (1-2-5 sequence in 24steps) (SS-7825)

Max. sweep rate 500 ps/div (SS-7840), 1 ns/div (SS-7825)Hold-off time Variable

B sweep Delay TRIG'D DELAY, RUNS AFTER DELAYSweep rate 5 ns/div – 20 ms/div (1-2-5 sequence in 21

steps) (SS-7840) 0 ns/div – 20 ms/div (1-2-5 sequence in 20steps (SS-7825)

Max. sweep rate 500 ps/div (SS-7840) 1 ns, div (SS-7825)Delay time Range 0.2 div – 10.2 div of A sweep

Delay jitter 1/20000 at 1 ms/div of A sweep, 500 ns/div of Bsweep

Sweep magnification X10n X-Y operation X axis (CH1)Sensitivity Same as CH1

Accuracy ±2%Frequency bandwidth DC – 2 MHz -3 dB

Y axis CH1, CH2, CH3, CH4, ADDPhase difference Within 3˚ (DC – 200 kHz) n CAL (calibration signal)Waveform Square-waveFrequency 1 kHz, ±0.1%Duty ratio 49% – 51%Output voltage 0.6 V, ±1%n CH2 OUTOutput voltage 20 mV/div, ±30% (50 Ω load)Frequency bandwidth 200 MHz, -3 dB (50 Ω load)

(100 MHz for SS-7825)Output resistance 50 Ω, ±20%n Probe powerConnector number 2Voltage +12V, -12Vn Z AXIS INModulation voltage 0.5 Vp-p or morePolarity With positive voltage, dark: with negative

voltage, brightFrequency bandwidth DC – 5 MHzInput resistance 5 kΩ ±20%Max. input voltage ±40 V max.n Cursor measurement Time difference (∆t), voltage difference (∆V)n CounterDisplay digits 5-digit (A trigger source) Accuracy ±0.01%Frequency range 2 Hz – 400 MHz (SS-7840) 2 Hz – 250 MHz

(SS-7825)n Save/ Recall Max. 256 panel settings Backup time Approx. 30,000H (at 25 ˚C)n Power supplyVoltage range AC 100 V – 240 VFrequency range 50 Hz – 400 HzPower consumption Max. 120 VAn Weight and dimensionsWeight Approx. 8.5 kg (without accessories)Dimensions Approx. 320W x 160H x 420L mmn Environmental conditions Performance guaranteed +10 – +35 ˚C

temperatureOperating range

Temperature 0 – +40 ˚CHumidity 90% RH (0 – 40 ˚C)

Storage rangeTemperature -20 – +40 ˚CHumidity 80% RH (-20 – +40 ˚C)

n Accessories Power cord (x1), probe (x2), panel cover (1 ),fuse (x2), operation manual (x1 ), accessory bag(x1 )

HF-REJ: Attenuates at 10 kHz or moreHF-REJ: Attenuates at 10 kHz or less

B triggeringSource CH1, CH2, CH3, CH4Coupling AC, DC, HF-REJ, LF-REJ Slope +, –Sensitivity

*SS-7840/7840H

HF-REJ: Attenuates at 10 kHz or moreHF-REJ: Attenuates at 10 kHz or less

TV triggerFormat NTSC, PAL (SECAM), HDTVTrigger mode TV-V (ODD, EVEN, BOTH), TV-H

NTSC 1 H – 525 HPAL (SECAM) 1 H – 625 HHDTV 1 H – 1125 H

TV clampClamp position Back porch levelClamp level Within ±1 divSignal amplitude 1.5 div – 8 div

Frequency AmplitudeDC – 10 MHz 0.4 div

10 MHz – 100 MHz 1.0 div100 MHz – 400 MHz 2.0 div

Frequency AmplitudeDC – 10 MHz 0.4 div

10 MHz – 100 MHz 1.0 div*100 MHz – 250 MHz 2.0 div

p01-p26 00.9.28 2:06 PM ページ 10

Page 12: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

11

SS-7802A• DC – 20 MHz, 2 CH, + Ext. trigger input,

3 traces • Cursor measurement function• 52% accuracy for vertical axis sensitivity• Input connector with probe sensor (probe with

sensor is optionally available)• Full TV triggering with TV line selection capability• 5-digit frequency counter• Single-sweep function

SS-7804• DC – 40 MHz, 2 CH, + Ext. trigger input,

3 traces • Cursor measurement function• 52% accuracy for vertical axis sensitivity• Input connector with probe sensor (probe with

sensor is optionally available)• Bright and sharp display with 16 kV accelerating

voltage CRT • Full TV triggering with TV line selection capability• 5-digit frequency counter

SS-7810• DC – 100 MHz, 3 CH, 8 traces • Quick auto setup• Full TV triggering with field and line selection• Maximum sensitivity of 2 mV/div• 5-digit frequency counter• Cursor measurement/panel settings readout

function• CH3 sensitivities of 50 mV, 100 mV, 500 mV/div

SS-7821/7811• DC – 200 MHz, 3 CH, 8 traces (SS-7821)

DC – 100 MHz, 3 CH, 8 traces (SS-7811)• Save/recall of up to 32 panel settings• Quick auto setup• Full TV triggering with field and line, HDTV

(SS-7821)• High sensitivity of 2 mV/div, fastest sweep of

1 ns/div (SS-7821)• 5-digit frequency counter• Cursor measurement/panel settings readout

function• CH3 sensitivities of 50 mV, 100 mV, 500 mV/div

comprehensive features make these analogoscilloscopes ideal for use in a broad range ofapplications from R & D to manufacturing andeducation.

Combining high precision with excellent operability,IWATSU's lineup of analog oscilloscopes delivers thehigh performance and multiple functions demanded ofgeneral-purpose oscilloscopes. Proven reliability and

Analog Oscilloscopes SS-7821/7811/7810/7804/7802A

p01-p26 00.9.28 2:06 PM ページ 11

Page 13: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

12

m Sharp, high-brightness CRTHigh-quality CRTs are essential parts for the performance of analogoscilloscopes. To ensure that our oscilloscopes meet the higheststandards, IWATSU designs and manufactures its own CRTs in itsown factory. The IWATSU-developed meshless box lens CRT allowswaveforms to be observed as bright and sharp traces on the screen.

m Full TV triggeringTV-V (ODD, EVEN, BOTH field) and TV-H are available. The linenumber selection in TV-V mode is useful for detailed video signalevaluations. This same function is also featured in all modelsincluding the 20 MHz SS-7820A. SS-7821 can be selected in HDTVformat in addition to NTSC or PAL/SECAM.

m 5-digit counterA 5-digit counter displays the frequency of triggering signals.Accuracy is ±0.01%. (6-digit: Factory option)

m CH3 sensitivity selectable (three ranges)(SS-7821/SS-7811/SS-7810)

While CH3 sensitivity on conventional models can be switched at twolevels or not at all, these models offer 3-range CH3 input, makingthem ideal for various applications such as ECL, TTL and 24-Vsystems.

m Convenient LED displayLEDs show measurement settings and ensure easy operation.

m High accuracy (±2% for all channels) Voltage precision is the key to oscilloscope performance. Withaccuracy of ±2%, all models of this series offer unprecedentedperformance that puts them at the top of their class.

m Convenient auto setup (SS-7821/SS-7811/SS-7810)

Quick auto setup function automatically sets the optimum vertical axissensitivity, time axis, trigger level, etc. for waveform display.

m Instant cancellation of readout and cursor indications

At the touch of a button, the cursor and readout display can be madeto disappear from the screen, leaving only the waveform. Pressingthe button again restores the indications.

m Save/recall of up to 32 panel settings (SS-7821/SS-7811)

Frequently required measurement settings can be saved andrecalled. Sequential recall can be performed easily and items beingrecalled can be changed just by turning the FUNCTION knob. Helpfulfor production lines requiring sequential recall of preset settings.

m Easy-to-use logical layout panel with nomenu selection required

IWATSU's in-depth technical expertise and ergonomic approach hasresulted in oscilloscopes that are extremely easy to use. Instead ofemploying an unwieldy and complex menu system, theseoscilloscopes feature a simple, one-touch system for all frequentlyused basic operations.

m Cursor and readout functionCursor and readout functions are provided on all models including the20 MHz model.

p01-p26 00.9.28 2:06 PM ページ 12

Page 14: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

13

TV triggerFormat NTSC, PAL (SECAM), HDTVTrigger mode TV-V (ODD, EVEN, BOTH), TV-HNTSC 5 H – 2000 HPAL (SECAM),HDTV 2 H – 1997 H

AUTO SETUPInput channel CH1, CH2Frequency range 50 Hz – 50 MHz n Horizontal deflection system (X axis)Display (HORIZ DISPLAY) A, ALT, B, X-Y A sweepSweep mode AUTO NORMAL SINGLESweep rate 10 ns/div – 500 ms/div (1-2-5 sequence in 24

steps)Max. sweep rate 1 ns/divHold-off time Variable B sweepDelay TRIG’D DELAY, RUNS AFTER DELAYSweep rate 10 ns/div – 5 ms/div (1-2-5 sequence in 18

steps)Max. sweep rate 1 ns/divDelay timeRange 0.2 div – 10.2 div of A sweepDelay jitter 1/20000 at 1 ms/div of A sweep, 500 ns/div of B

sweep Sweep magnification X10n X-Y operation X axis CH1Sensitivity Same as CH1Accuracy ±4%Frequency bandwidth DC – 2 MHz –3 dB Y axis CH1, CH2, CH3, ADDPhase difference Within 3˚ (DC – 200 kHz)n CAL (calibration signal)Waveform Square waveFrequency 1 kHz ±0.1%Duty ratio 49% – 51%Output voltage 0.6V ±1%n Cursor measurement Time difference (∆t), voltage difference (∆V) n Counter 5-digit (A trigger source)Accuracy ±0.01%Frequency range 2 Hz – 100 MHzn Save/recall Max. 32 panel settings Backup time Approx. 30,000H (at 25°C)n Power supplyVoltage range AC 100 V – 120 V, 200 V – 240 VFrequency range 50 Hz – 400 HzPower consumption Max. 110 VAWeight and dimensionsWeight Approx. 7.5 kg (without accessories)Dimensions Approx. 272W x 152H x 390L mmn Environmental conditionsPerformance guaranteed +10 – +35°CtemperatureOperating rangeTemperature 0 – +40°CHumidity 90% RH (0 – 40°C)Storage rangeTemperature –20 – +40°CHumidity 80% RH –20 – +40°C)n Accessories Power cord (x1), probe (x2), panel cover (1 ),

fuse (x2), operation manual (x1 )

DC – 200 MHz, 3 CH, 8 traces

Save/recall of up to 32 panel settings Quick auto setup Full NTSC, PAL (SECAM), HDTV TV triggering

with field and line 2 mV/div high sensitivity and 1 ns/div sweep rate 5-digits frequency counter Cursor function 50 mV, 100 mV, 500 mV/div CH3 ranges

n CRTShape 6-inch rectangular. internal graticule, meshless

CRT with scale illumination Effective area 8 x 10 div (1 div = 10 mm)Accelerating voltage Approx. 16 kVn Vertical deflection system (Y axis)Vertical mode CH1, CH2, CH3, ADD (CH1 + CH2)

ALT, CHOP (555 kHz ±1%) CH1, CH2Sensitivity 2 mV/div – 5 V/div (1-2-5 sequence in 11 steps)Variable adjuster 2 mV/div – 12.5 V/div. continuously variableAccuracy ±2 %Frequency bandwidth DC – 200 MHz –3 dB

DC – 50 MHz –3 dB at 2 mV/divNote: The lower limit frequency is 10 Hz with

AC coupling Bandwidth limiter DC – 20 MHzRise time Approx. 1.75 ns

Note: Calculated from the following formula

Signal delay time 30 ns or more (on the screen)Input coupling AC, DC, GNDInput RC 1 MΩ ±1.5% // 20 pF ±2 pFMax. input voltage ±400 V (DC + AC peak)Polarity switching CH2 onlyProbe sense 1:1, 10:1, 100:1 CH3Sensitivity 50 mV, 100 mV, 500 mV/divAccuracy ±3%Frequency bandwidth DC – 200 MHz, –3 dBInput coupling AC, DCInput RC 1 MΩ ±1.5% // 20 pF ±3 pFMax. input voltage ±400 V (DC + AC peak)Probe sense 1:1, 10:1, 100:1n Triggering A triggeringTrigger mode EDGE, TVSource VERT, CH1, CH2, CH3, LINECoupling AC, DC, HF-REJ, LF-REJSlope +, –Sensitivity

HF-REJ: Attenuates at 10 kHz or moreHF-REJ: Attenuates at 10 kHz or less

B triggeringSource CH1, CH2, CH3Coupling AC, DC, HF-REJ, LF-REJSlope +, –Sensitivity

HF-REJ: Attenuates at 10 kHz or moreHF-REJ: Attenuates at 10 kHz or less

350Tr = [ns]

Bandwidth [MHz]

Frequency AmplitudeDC – 10 MHz 0.4 div10 MHz – 100 MHz 1.0 div100 MHz – 200 MHz 1.5 div

Frequency AmplitudeDC – 10 MHz 0.4 div10 MHz – 100 MHz 1.0 div100 MHz – 200 MHz 1.5 div

Specifications

Analog Oscilloscope SS-7821

p01-p26 00.9.28 2:06 PM ページ 13

Page 15: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

14

TV triggerFormat NTSC, PAL (SECAM)Trigger mode TV-V (ODD, EVEN, BOTH), TV-H NTSC 5 H – 2000 HPAL (SECAM) 2 H – 1997 H

AUTO SETUPInput channel CH1, CH2Frequency range 50 Hz – 50 MHzn Horizontal deflection system (X axis)Display (HORIZ DISPLAY) A, ALT, B, X-Y A sweepSweep mode AUTO NORMAL SINGLESweep rate 20 ns/div – 500 ms/div (1-2-5 sequence in 24

steps)Max. sweep rate 2 ns/divHold-off time Variable B sweepDelay TRIG’D DELAY, RUNS AFTER DELAYSweep rate 20 ns/div – 5 ms/div (1-2-5 sequence in 18

steps)Max. sweep rate 2 ns/divDelay timeRange 0.2 div – 10.2 div of A sweepDelay jitter 1/20000 at 1 ms/div of A sweep, 500 ns/div of B

sweep Sweep magnification X10n X-Y operation X axis CH1Sensitivity Same as CH1Accuracy ±4%Frequency bandwidth DC – 2 MHz -3 dB Y axis CH1, CH2, CH3, ADDPhase difference Within 3˚ (DC – 200 kHz)n CAL (calibration signal)Waveform Square wave Frequency 1 kHz ±0.1%Duty ratio 49% – 51%Output voltage 0.6V ±1%n Cursor measurement Time difference (∆t), voltage difference (∆V)n Counter 5-digit (A trigger source)Accuracy ±0.01%Frequency range 2 Hz – 100 MHz

n Save/recall (SS-7811 only) Max. 32 panel settingsBackup time Approx. 30,000H (at 25°C)n Power supplyVoltage range AC 100 V – 120 V, 200 V – 240 VFrequency range 50 Hz – 400 HzPower consumption Max. 110 VAn Weight and dimensionsWeight Approx. 7.5 kg (without accessories)Dimensions Approx. 272W x 152H x 390L mmn Environmental conditionsPerformance guaranteed +10 – +35°CtemperatureOperating rangeTemperature 0 – +40°CHumidity 90% RH (0 – 40°C)Storage rangeTemperature –20 – +40°CHumidity 80% RH (-20 – +40°C)n Accessories Power cord (x1), probe (x2), panel cover (1 ),

fuse (x2), operation manual (x1 )

DC – 100 MHz, 3 CH, 8 traces

Save/recall of up to 32 panel settings (SS-7811only)

Quick auto setup Full NTSC, PAL (SECAM) TV triggering with field

and line 2 mV/div high sensitivity and 2 ns/div sweep rate 5-digits frequency counter Cursor function 50 mV, 100 mV, 500 mV/div CH3 ranges

n CRTShape 6-inch rectangular. internal graticule, meshless

CRT with scale illuminationEffective area 8 x 10 div (1 div = 10 mm)Accelerating voltage Approx. 16 kVn Vertical deflection system (Y axis)Vertical mode CH1, CH2, CH3, ADD (CH1 + CH2)

ALT, CHOP (555 kHz ±1%) CH1, CH2Sensitivity 2 mV/div – 5 V/div (1-2-5 sequence in 11 steps)Variable adjuster 2 mV/div – 12.5 V/div. continuously variableAccuracy ±2 %Frequency bandwidth DC – 100 MHz –3 dB

DC – 50 MHz – 3 dB at 2 mV/divNote: The lower limit frequency is 10 Hz with

AC couplingBandwidth limiter DC –20 MHzRise time Approx. 3.5 ns

Note: Calculated from the following formula

Signal delay time 30 ns or more (on the screen)Input coupling AC, DC, GNDInput RC 1 MΩ ±1.5% // 20 pF ±2 pFMax. input voltage ±400 V (DC + AC peak)Polarity switching CH2 onlyProbe sense 1:1, 10:1, 100:1 CH3Sensitivity 50 mV, 100 mV, 500 mV/divAccuracy ±3%Frequency bandwidth DC – 100 MHz, –3 dBInput coupling AC, DCInput RC 1 MΩ ±1.5% // 20 pF ±3 pFMax. input voltage ± 400 V (DC + AC peak)Probe sense 1:1, 10:1, 100:1n Triggering A triggeringTrigger mode EDGE, TVSource VERT, CH1, CH2, CH3, LINECoupling AC, DC, HF-REJ, LF-REJSlope +, –Sensitivity

HF-REJ: Attenuates at 10 kHz or moreHF-REJ: Attenuates at 10 kHz or less

B triggeringSource CH1, CH2, CH3Coupling AC, DC, HF-REJ, LF-REJSlope +, –Sensitivity

HF-REJ: Attenuates at 10 kHz or moreHF-REJ: Attenuates at 10 kHz or less

350Tr = [ns]

Bandwidth [MHz]

Frequency AmplitudeDC – 10 MHz 0.4 div10 MHz – 100 MHz 1.0 div

Frequency AmplitudeDC – 10 MHz 0.4 div10 MHz – 100 MHz 1.0 div

Specifications

Analog Oscilloscopes SS-7811/7810

p01-p26 00.9.28 2:06 PM ページ 14

Page 16: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

15

n Horizontal deflection system (X axis)Display (HORIZ DISPLAY) A, X-YSweep mode AUTO NORMAL SINGLESweep rate 100 ns/div – 500 ms/div (1-2-5 sequence in 24

steps)Max. sweep rate 10 ns/divHold-off time Variable Sweep magnification X10n X-Y operationX axis CH1Sensitivity Same as CH1Accuracy ±4%Frequency bandwidth DC – 2 MHz –3 dBY axis CH1, CH2, ADDPhase difference Within 3° (DC – 50 kHz)

n CAL (calibration signal)Waveform Square waveFrequency 1 kHz ±0.1%Duty ratio 49% – 51%Output voltage 0.6V ±1%n Cursor measurement Time difference (∆t), voltage difference (∆V)n Counter 5-digit (A trigger source)Accuracy ±0.01%Frequency range 2 Hz – 40 MHz

n Panel setting A panel setup just before power off is savedBackup time Approx. 30,000H (at 25°C)n Power supplyVoltage range AC 100 V – 120 V, 200 V – 240 VFrequency range 50 Hz – 400 HzPower consumption Max. 110 VAWeight and dimensionsWeight Approx. 7.5 kg (without accessories)Dimensions Approx. 272W x 152H x 390L mmn Environmental conditionsPerformance guaranteed +10 – +35°C

temperatureOperating rangeTemperature 0 – +40˚CHumidity 90% RH (0 – 40°C)Storage rangeTemperature –20 – +40°CHumidity 80% RH (-20 – +40°C)n Accessories Power cord (x1), probe (x2), panel cover (1),

fuse (x2), operation manual (x1)

DC – 40 MHz, 2 CH, EXT trigger, 3traces

High brightness CRT by 16 kV acceleratingvoltage

2 mV/div high sensitivity and 10 ns/div sweep rate Full NTSC, PAL (SECAM) TV triggering with field

and line 2% accuracy Input connector with probe sensor (Probe with

sensor is optionally available) 5-digits frequency counter Read out and Cursor function Self auto balance adjust function Trace rotation function

n CRTShape 6-inch rectangular. internal graticule, meshless

CRT with scale illumination Effective area 8 x 10 div (1 div = 10 mm)Accelerating voltage Approx. 16 kVn Vertical deflection system (Y axis)Vertical mode CH1, CH2, ADD (CH1 + CH2)

ALT, CHOP (555 kHz ±1%)CH1, CH2Sensitivity 2 mV/div – 5 V/div (1-2-5 sequence in 11 steps)Variable adjuster 2 mV/div – 12.5 V/div. continuously variableAccuracy ±2 %Frequency bandwidth DC – 40 MHz -3 dB

DC – 20 MHz -3 dB at 2 mV/divNote: The lower limit frequency is 10 Hz with

AC coupling Rise time Approx. 8.75 ns

Note: Calculated from the following formula

Signal delay time 30 ns or more (on the screen)Input coupling AC, DC, GNDInput RC 1 MΩ ±1.5% // 25 pF ±2 pFMax. input voltage ±400 V (DC + AC peak)Polarity switching CH2 onlyProbe sense 1:1, 10:1, 100:1n TriggeringTrigger mode EDGE, TVSource VERT, CH1, CH2, EXT, LINECoupling AC, DC, HF-REJ, LF-REJSlope +, –Sensitivity

HF-REJ: Attenuates at 10 kHz or moreHF-REJ: Attenuates at 10 kHz or less

EXT TRIGCoupling DCInput RC 1 MΩ ± 1.5% // 25 pF ±3 pFMax. input voltage ±400 V (DC + AC peak)TV triggerFormat NTSC, PAL (SECAM) Trigger mode TV-V (ODD, EVEN, BOTH), TV-HNTSC 5 H – 2000 HPAL (SECAM) 2 H – 1997 H

350Tr = [ns]

Bandwidth [MHz]

Frequency CH1, CH2 EXTDC – 5 MHz 0.4 div 80 mV 5 MHz – 40 MHz 1.0 div 200 mV

Specifications

Analog Oscilloscope SS-7804

p01-p26 00.9.28 2:06 PM ページ 15

Page 17: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

16

n Horizontal deflection system (X axis)Display (HORIZ DISPLAY) A, X-YSweep mode AUTO NORMAL SINGLESweep rate 200 ns/div – 500 ms/div (1-2-5 sequence in 24

steps)Max. sweep rate 20 ns/divHold-off time VariableSweep magnification X10n X-Y operationX axis CH1Sensitivity Same as CH1Accuracy ±4%Frequency bandwidth DC – 1 MHz -3 dB

Y axis CH1, CH2, ADDPhase difference Within 3° (DC – 20 kHz)n CAL (calibration signal) Waveform Square wave Frequency 1 kHz ±0.1%Duty ratio 49% – 51%Output voltage 0.6V ±1% n Cursor measurement Time difference (∆t), voltage difference (∆V)n Counter 5-digit (A trigger source)Accuracy ± 0.01%Frequency range 2 Hz – 20 MHzn Panel setting A panel setup just before power off is savedBackup time Approx. 30,000H (at 25˚C)n Power supply Voltage range AC 100 V, 110 – 120 V, 220 V, 230 – 240 VFrequency range 50 Hz – 60 HzPower consumption Max. 60 VAWeight and dimensionsWeight Approx. 8.5 kg (without accessories)Dimensions Approx. 272W x 152H x 390L mmn Environmental conditionsPerformance guaranteed +10 – +35°C

temperatureOperating rangeTemperature 0 – +40°CHumidity 90% RH (0 – 40°C)Storage rangeTemperature –20 – +40°CHumidity 80% RH (-20 – +40°C)n Accessories Power cord (x1), probe (x2), panel cover (1 ),

operation manual (x1)

DC – 20 MHz, 2 CH, EXT trigger, 3traces

2 mV/div high sensitivity and 20 ns/div sweep rate Full NTSC, PAL (SECAM) TV triggering with field

and line 2% accuracy Input connector with probe sensor (Probe with

sensor is optionally available) 5-digits frequency counter Self auto balance adjust function Trace rotation function Single sweep function

n CRTShape 6-inch rectangular, internal graticule CRTEffective area 8 x 10 div (1 div = 10 mm)Accelerating voltage Approx. 2 kVn Vertical deflection system (Y axis)Vertical mode CH1, CH2, ADD (CH1 + CH2)

ALT, CHOP (555 kHz ±1%)CH1, CH2 Sensitivity 2 mV/div – 5 V/div (1-2-5 sequence in 11 steps)Variable adjuster 2 mV/div – 12.5 V/div. continuously variableAccuracy ±2 %Frequency bandwidth DC – 20 MHz –3 dB

DC – 10 MHz –3 dB at 2 mV/divNote: The lower limit frequency is 10 Hz with

AC coupling Rise time Approx. 17.5 ns

Note: Calculated from the following formula

Input coupling AC, DC, GNDInput RC 1 MΩ ±1.5% // 25 pF ±2 pFMax. input voltage ±400 V (DC + AC peak)Polarity switching CH2 onlyProbe sense 1:1, 10:1, 100:1n TriggeringTrigger mode EDGE, TV Source VERT, CH1, CH2, EXT, LINECoupling AC, DC, HF-REJ, LF-REJSlope +, –Sensitivity

HF-REJ: Attenuates at 10 kHzHF-REJ: Attenuates at 10 kHz or less

EXT TRIGCoupling DCInput RC 1 MΩ ±1.5% // 25 pF ±3 pFMax. input voltage ±400 V (DC + AC peak)TV triggerFormat NTSC, PAL (SECAM)Trigger mode TV-V (ODD, EVEN, BOTH), TV-HNTSC 5 H – 2000 HPAL (SECAM) 2 H – 1997 H

350Tr = [ns]

Bandwidth [MHz]

Frequency CH1, CH2 EXTDC – 5 MHz 0.4 div 80 mV 5 MHz – 20 MHz 1.0 div 200 mV

or more

Specifications

Analog Oscilloscope SS-7802A

p01-p26 00.9.28 2:06 PM ページ 16

Page 18: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

17

m Easy-to-save panel setup Panel setup conditions can be saved via front panel operation with nospecial knowledge required, unlike when using GP-IB commands.

m Quick and direct readout requiring no m interface

When used together with an optional Manual Box, setup conditionscan be recalled or saved quickly and easily.

The new Programmable Oscilloscopes SS-7840P/ SS-7811P/SS-7804P have been developed exclusivelyfor manufacturing line use. With a built-in CPU,programming functions are made simple, and the setupdata can be up loaded to the oscilloscope from apersonal computer. This greatly reduces the re-programming procedures that are inevitably requiredwhen the product on the line is changed.Quicker response (when compared with the control viaGP-IB interface) also contributes to improvements inproductivity.Iwatsu's peripheral components (optional accessories),developed using our long experience and waryachievements, also simplify the re-configuration of yourmanufacturing line.

• Quick and direct readout requiring nointerface

• Easy-to-save/recall panel setup• Flexible Bank setting capability• Bulk of panel setup data can be saved in

and loaded from a personal computer

m Concurrent loading of setup conditionsWhen personal computers (IBM PC/AT and compatibles) are used,panel setup data can be downloaded onto the floppy disk or uploadedto the oscilloscope together. This feature greatly reduces setupprocedures required for re-programming two or more SS-7800PSeries oscilloscopes.

m 12-character comment input capabilityfor each setup data

Up to 12 characters can be input as a comment about eachmanufactured product (name, etc.), allowing effective use of setupdata.

m Compatible with 8-bit BCD binary codein conventional automatic control line

The 8-bit BCD (binary coded decimal) binary codes that are used forcontrolling the other equipment in the manufacturing line can be usedfor controlling the bank and program step numbers of the SS-7800P .

m Flexible bank settingThe 255-step memory area can be used in various configurations,from a single bank with 255 steps to 63 banks with 4 steps each. Thisis convenient when 1 bank is used for each manufacturing product.

SETUP THE PANEL PUSH KNOB TURN KNOB TO

Manual Box

RESET

Step 1 Step 2 Step 3SAVE !!

Personal Computer

1 BANK

255 steps 63 steps 4 steps

4 BANK

63 BANK

SS-7840PDC – 400 MHz

SS-7811PDC – 100 MHz, 3 CH

SS-7804PDC – 40 MHz, 2 CH

Programmable Oscilloscopes SS-7840P/7811P/7804P

p01-p26 00.9.28 2:06 PM ページ 17

Page 19: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

18

m Pedestal (DC level) Clamping UnitClamps the composite video signal level in order to stabilize thedisplay.

m Comment Input SoftwareConvenient software enabling the input of comments from yourpersonal computer.

m Input Selector, MPX (Multiplexer)A compact 8-channel input selector can be installed in an aluminumchassis if required. A maximum 32-channel input can be connectedto the oscilloscope when the input selector is expanded.

m ControllerControls the SS-7800P-series oscilloscope and its peripheralequipment according to its specified control signal.

SS-7840P SS-7811P SS-7804P

Programmable function

Setup memory Max. 255 steps, can be divided into 1 bank/255 steps to 63 banks/4 steps

Comment input Up to 12 characters for each step

Save mode

Manual Manually saved from the front panel

Setup data transferring Setup data can be transferred to/from an IBM/PC or compatible PC

Recall mode

Manual Manually recalled from the function knob on the front panel

Manual controller Manually controlled sequentially by UP/DOWN switch with initializing switch

Interfacing Direct recalling by 8-bit binary code

Connector: D-sub 25-pin, input signal: TTL level, input voltage: –0.5 V min. – +7 V max.

Others Same as SS-7840/7811/7804

Specifications

p01-p26 00.9.28 2:06 PM ページ 18

Page 20: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

19

DIGITAL STORAGE OSCILLOSCOPE SELECTION GUIDE

Specification DS-8812 DS-8710 DS-8617 DS-8608A DS-8607AHandy, Battery Full 4CH

2CH Compact operation with real 2CH with real 2CH with realDisplay Type TFT LCD TFT LCD CRT CRT CRT

Size 5.8” 8 x 10 div 5” 8 x 10 div 6” 8 x 10 cm 6” 8 x 10 cm 6” 8 x 10 cmStorage Bandwidth 100 MHz 100 MHz 100 MHz 100 MHz 60 MHz

Input Channels 2 2 4 2 2Max. Sampling rate 500 MS/s 20 MS/s 100 MS/s 20 MS/s 20 MS/sResolution 8 bits 8 bits 8 bits 8 bits 8 bitsMax. Memory length/ch 100 k 8 k 32 k 4 k 4 kEquivalent sampling Yes Yes Yes Yes YesEnvelope or Peak Detect Yes Yes Yes Yes —Roll Yes Yes Yes Yes YesAveraging Yes Yes Yes Yes YesMax. Hold — — Yes Yes YesSmoothing — — Yes Yes YesInterpolation Stair (Pulse) — Yes Yes — —

Linear Yes Yes Yes Yes YesSine — — Yes — —

Math Add, Sub, Multi Add, Sub, Multi Add, Sub, Multi Add, Sub Add, SubHelp Yes — — — —

Interface FDD Yes — — — —ATA Card Yes Yes — — —RS-232C Yes Yes Yes option Yes option Yes option

GP-IB Yes option — Yes Yes option Yes optionCentronics Yes Yes Yes Yes option Yes option

Built in Printer Yes — — — —Vertical CH1, 2 Range 2 mV – 5 V/div 2 mV – 5 V/div 2 mV – 10 V/div 5 mV~5 V/div 5 mV~5 V/div

Coupling AC DC GND AC DC GND AC DC GND AC DC GND AC DC GNDInput R 1 MΩ ±1.5% 1 MΩ ±1.5% 1 MΩ ±1.5% 1 MΩ ±1.5% 1 MΩ ±1.5%Input C 16 pF ± 2pF 25 pF ±2.5 pF 23 pF ±2 pF 25 pF ±2 pF 25 pF ±2 pF

B/W Limit 20 MHz 10 MHz 20 MHz — —Probe Sense Yes — Yes — —

CH3, CH4 — — Same as CH1 — —Trigger Source CH1,2,Ext,Line CH1,2,Ext CH1,2,3,4,Line CH1,2,Ext,Line CH1,2,Ext,Line

Coupling AC, DC, HF-R, LF-R Yes Yes Yes Yes YesEvent Count Yes Yes Yes — —

Burst Yes Yes Yes — —Extra Yes Yes Yes — —

Event Missing Yes Yes Yes — —TV Trig NTSC, PAL(SECAM) Yes Yes Yes TV-V TV-V

Line number select Yes Yes Yes — —Sweep A Sweep Fastest Sweep Rate 5 ns/div 10 ns/div 2 ns/div 2 ns/div 2 ns/div

Slowest Sweep Rate 50 s/div 50 s/div 50 s/div 50 s/div 50 s/divHold off Yes Yes Yes Yes YesB Sweep Trigger Delay — — Yes — —

Fastest Sweep Rate — — 2 ns/div — —Slowest Sweep Rate — — 20 ms/div — —

Trace Separation — — Yes — —ALT Sweep — — Yes — —

X-Y X Range CH1 CH1 CH1 or Ref1 CH1 CH1Bandwidth 100 MHz 100 MHz 100 MHz 100 MHz 2 MHz (real)

Y Range CH2 CH2 CH, Ref, 1to4 CH2 CH2Cursor ∆V, ∆t, 1/∆t Yes Yes Yes Yes YesAuto Measurement 13 items 14 items 9 items 9 items 9 itemsCounter Frequency Range 100 MHz 100 MHz 100 MHz — —Auto Setup V, H Posi, V, H range, Trigger Yes Yes Yes Yes YesSave/recall Yes Yes Yes Yes YesGO/NOGO — — Yes — —Signal OUT — — CH2 CH1 CH1CAL OUT 1 kHz 0.6 V Yes Yes Yes Yes YesPower AC Range 100V– 240V Yes — Yes Yes Yes

100, 115, 230V — AC adapter — — —Frequency 50/60 Hz 50/60 Hz 50/60/400 Hz 50/60/400 Hz 50/60/400 HzConsumption 90 VA 12 W 200 W 80 W 80 WBattery Operation — Yes — — —

Dimensions W x H x L (mm) 215 x 170 x 166 170 x 62 x 250 320 x 160 x 423 330 x 132 x 365 330 x 132 x 365Weight 3 kg 1.3 kg body only 11 kg 6.8 kg 6.8 kgAccessories Power cord, Fuse, Manual (1) Yes Yes Yes Yes Yes

Two Probes with probe sense Yes — Yes — —Two Probes without probe sense — Yes — Yes YesPanel cover (1) — — Yes — —

p01-p26 00.9.28 2:06 PM ページ 19

Page 21: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

20

DS-8710 DC — 100 MHz, 2CH

The DS-8710 is a compact digital storage oscilloscopewith a frequency bandwidth of DC – 100 MHz.Incorporating a high-contrast, high-brightness LCD, thisscope can display varying waveforms at fast speeds.

m Minimum time resolution of 100 ps (Equivalent to10 GS/s)

m PCMCIA-standard card slot

m Automatic Vrms measurement of waveformeffective values

m High-speed waveform refresh function (approx. 90 times/sec.)

m Quick auto set-up functionm Powerful auto measurement function

m Compact and lightm Suitable for field maintenancem Backlit LCD for clear, bright screenm Large 8-kword memorym Automatic skew measurement enables

observation of time difference between twochannels

DS-8710Display High contrast LCD display, 320 dots x 240 dots (High brightness backlit EL)Fastest sampling speed 20 MS/s, simultaneous on both channelsInput channel 2 channels (EXT triggering is available)Sensitivity 2 mV/div – 5 V/div, 11 steps (1-2-5)Frequency bandwidth EQU: DC – 100 MHz, –3 dBVertical resolution 8 bits, 30 levels/divMemory length 8 kW/ch (16 kW/ch at Roll mode)Acquisition modes Equivalent Sample, Envelope. Average, RollSweep range 10 ns/div – 50 s/div, 30 steps (1-2-5)

ROLL: 0.5 s/div – 50 s/divMagnifier 5,000 times maximumAuto setup function AvailableRemote auto measurement AvailableConditional judgement AvailableFrequency counter 5-digit (reciprocal), Accuracy: ±0.01%Clock function AvailableCursor measurement & Tr, Tf. V-rms, Frequency, Period. AverageAuto measurement ±pulse width, ±peak.

Time difference (CH1-CH2).Duty cycle, Vp-p. V at T

Trigger modes Level, Event, TV (TV-Line selectable)Save/Recall Setup: 100 kinds; Waveform data: 10 kindsMemory expansion Available with PCMCIA memory cardPrinter port For connection of external printerInterface RS-232-C/PCMCIABattery operation AvailableDimensions Approx. 170 W x 62 H x 250 L mmWeight Approx. 1.3 kg (w/o accessory)Accessories AC to DC adaptor (x1), SS-0120 probe (x2)

Operation manual (x1), carrying case

Digital Storage Oscilloscope DS-8710

Major Specifications

p01-p26 00.9.28 2:07 PM ページ 20

Page 22: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

21

m 4096 words/ch memory lengthEach channel has a 4096-word acquisition memory, allowing for theobservation of waveforms requiring a large memory capacity.

m Easy operation/setting, 2-channel digitalstorage scope with real-time capability

m High-speed auto set-upJust pressing the AUTO SET key displays a waveform in the optimumsize and position on the CRT screen.

m Equivalent sampling of 60 MHz (DS-8607A)/100 MHz (DS-8608A)

Using the random sampling method, the time resolution is 200 ps(equivalent to 5 GS/s). Also, waveforms before triggering can beobserved.

m Automatic acquisition mode selectiondepending on the sweep range

m Automatic sweep mode selection (with 2-ch measurement in real mode)

m CH1 ± CH2 waveform arithmeticoperation

Allows for CH1 + CH2 and CH1 – CH2 arithmetical operations onstored waveforms.

m Convenient cursor measurementUsing two cursors (2 vertical or 2 horizontal), the voltage difference(∆t), time difference (∆t) and frequency (1/∆t) of a specific waveformcan be measured.

m Three levels of magnification (x10, x20, x50)

With ALT Sweep, simultaneous observation of a x1 and a magnifiedwaveforms is possible.

Magnifiedwaveform

Originalwaveform

Magnified display

n Basic functions and performancecombined with simple operation andsetting

n 2-channel digital storage with real-timeoscilloscope

• DC–60 MHz (DS-8607A) /100 MHz (DS-8608A) +20 MS/s, 8 bits

• 2-channel simultaneous operationn 4096-word display of stored waveforms

DC – 100 MHz, 2 CH, 20 MS/s (DS-8608A)DC – 60 MHz, 2 CH, 20 MS/s (DS-8607A)

Digital Storage Oscilloscopes DS-8608A/8607A

p01-p26 00.9.28 2:07 PM ページ 21

Page 23: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

22

Specifications

n DisplayCRT 6-inch rectangular, internal graticule

(with scale illumination)Accelerating voltage approx. 16 kV

n Vertical deflection system (common to CH1 and CH2)Sensitivity 5 mV/div – 5 V/div 10 steps (1-2-5)

5 mV/div – 12.5 V/div (with variable)Accuracy (at real mode) 5 mV/div –5 V/div ±3%Accuracy (storage mode) ±(3% +1/32 div)

In the envelope mode, add 3.5%Frequency bandwidth DC – 100 MHz (*60 MHz), –3 dBRise time 3.5 nsec or less (*<5.8 nsec)Input coupling AC, DC, GNDInput RC 1 MΩ ±1.5% // 25 pF ±2 pF (direct)

10 MΩ ±3% // 13 pF ±2 pF (using SS-0120 probe)

Max. input direct; 400 V (DC + AC peak)using SS-0120; 600 V (DC + AC peak)

Mode CH1, ADD, CH2, X-Y (real mode)ALT 0.5 msec/div – 20 nsec/divCHOP 0.2 sec/div – 1 msec/div

Signal delay 30 nsec (displayed on CRT, realmode)

Polarity switching Possible only for CH2 (real mode)CMRR

1 kHz sine wave 50:1 (at 5 mV/div, real mode)20 MHz sine wave 15:1 (at 5 mV/div, real mode)

n TriggeringSource CH1, CH2, EXT, LINECoupling AC, DC, HF REJ (>10 kHz), LF

REJ, TV-VPolarity +, –EXT input

Level DC – 10 MHz: 0.1 V10 MHz – 100 MHz (*60 MHz): 0.25 V

Input RC 1 MΩ ±5% // 25 pF ±3pFMax. input direct; 400 V (DC + AC peak)

n Horizontal deflection systemMode AUTO, NORM, SINGLESweep system Normal, magnified (x10, 20, 50),

alternateSweep time

Real mode 20 ns/div – 0.2 s/div 22 steps (1-2-5)20 ns/div – 5 s/div (with variable)

Accuracy (real mode) 20 ns/div – 0.2 s/div ±3%Storage mode 20 ns/div – 5 s/div 27 steps (1-2-5)

Magnifier 10, 20 or 50 times, selectableFastest sweep 2 ns/divHold-off time Variable

n X-Y operationReal mode

Operating channels CH1: X, CH2: YSensitivity Same as CH1 and CH2Bandwidth DC – 2 MHz, –3 dBPhase difference 3° or less through DC – 100 kHz

Storage mode only available for DS-8608An CRT read-out

Read-out Sensitivity (range, variable)sweep timemagnification valuevalue at cursorcomment message, etc.

Cursor measurement ∆V (voltage measurement)∆T (time measurement)1/∆T

Comment input Number of characters: up to 40characters

n Storage modeFastest sampling speed 20 MS/s, simultaneous at both

channelsVertical resolution 8 bits, 32 points/div,

256 points/8 divMemory length Acquisition memory: 4 kW/ch

Display memory: 4 kW/ch x 4Frequency bandwidth EQU: DC – 100 MHz

(*DC – 60 MHz), –3 dBAcquisition mode (automatically switchable)

Equivalent sampling 20 ns/div – 10 ms/divSampling method Random samplingNormal sampling 20 µs/div – 0.2 s/divRoll mode 0.5 s/div – 50 s/divEnvelope (DS-8608A CH1) 50 µs/div – 50 s/div

Waveform magnification Horizontal: x1 – x100 timesafter freeze Mag. point: 0/8 – 7/8 in 10 div,

1/8 stepTrigger point 0/4 – 3/4 in 10 div, 1/4 stepArithmetic function CH1 +CH2, CH1–CH2

between 20 ns/div – 0.2 s/divAveraging 8, 16, 32, 64 or 128 times

between 20 µs/div – 0.2 s/divMax. hold 16, 32, 64, 128 or ∞

between 20 ms/div – 0.2 s/divInterpolation LINEAR (at magnifying)Save/Recall Setup: 2 kinds, data: 2 kinds

(REF 1, 2)n CH1 signal output

Output voltage 25 mV/div ±20% (with load of 50 Ω)Frequency bandwidth DC – 50 MHz, –3 dB (with load of

50 Ω)Output resistance 50 Ω ±20%

n CalibratorWaveform Square-wave

(duty ratio 49% – 51%)Frequency 1 kHz ±5%Voltage 0.6 Vp-p ±2%

n Z-axis input (real mode)Bandwidth DC – 1 MHzMax. input 50 V peakInput resistance 10 kΩ ±10%

n Options (factory option)Interface DS-520 GP-IB (IEEE488.1 – 1987 or

for GP-IB & RS-232-C compatible)RS-232-C (EIA-232-D or compatible)

Interface DS-521 GP-IB (IEEE488.1 – 1987 or for GP-IB & PRINTER compatible)

PRINTER (ESC/P or compatible)n Power supply

Voltage range AC 90 V – 250 VFrequency range 48 Hz – 440 HzPower consumption MAX 80 watts

(operating at AC 100 V)n Dimensions and weight

Dimensions Approx. 330(W) x 132(H) x 365(L)mm

Weight Approx. 6.8 kg (w/o accessory)n Accessories Power cord (x1), SS-0120 probe

(x2), Fuse (x2), Operational manual(x1), Accessory bag (x1)

n Environmental conditionsOperating temperature 0°C – +40°CPerformance guaranteed +10°C – +35°COperating humidity 40°C/90% RHStorage temperature –20°C – +70°CStorage humidity 70°C/80% RHPre-heat time Accuracy is guaranteed after 30

min. since power is on.

* for DS-8607A

p01-p26 00.9.28 2:07 PM ページ 22

Page 24: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

23

n Digital storage with real-timeoscilloscope

n Maximum sampling rate of 100 Msamples (4 channels, simultaneous), 8-bit resolution and 32 kwords/ch.

n DC — 100 MHz, 4 channels, 5 waveforms,10 traces, fastest sweep time of 1 ns/div

The need for digital storage oscilloscopes is increasingrapidly as more automated systems are constructedthat have various waveform analyses, processingfunctions and controllers. The DS-8617 is a digitalstorage oscilloscope with a 4-channel full-rangeattenuator, a maximum sampling rate of 100 MS/s (4-channel simultaneous operation) and an 8-bit resolutioncombined with a DC — 100 MHz, 4-channel real-timeoscilloscope capability.The DS-8617 has a memory capacity of 32 kwords/ch.Other abundant functions include a TV trigger, an eventtrigger, automatic measurement and printer output. Everything is specially designed to meet the user'sneeds in various types of fields.

m 4-channel scope equipped with 4-channel full-range attenuator

m Independent 32-kword memory for eachchannel

32-kword/ch memory is provided as standard. This long memoryallows the acquirement of waveforms for long periods of time.

m Combination of high-performance digitalstorage and real-time oscilloscope

Full-scale measurement is possible with high speed and highperformance in every area.Storage capability: 100 MS/s, 8 bits, 32 kwords/ch, high-speedwaveform refresh rate of 140 times/s max.Real-time capability: DC — 100 MHz, 4 channels, 5 waveforms, 10traces

m Auto setup functionThe required trace can be shown in the optimum position by simplypressing the auto setup key.

m Various functions for flexiblemeasurements

Provided with a TV trigger (NTSC, PAL/SECAM, HDTV, field or lineselectable), an event trigger, automatic measurement, automaticcalibration, save/recall, comment, original waveformacquisition/processing, nonstop motion waveform indication, andquick auto setup function, the DS-8617 covers a wide range of userrequirements.

m GP-IB interface provided as standardFull remote control can be performed from an external controller forwaveform data transfer or panel setting conditions.

DC – 100 MHz, 4 CH100 MS/s

Digital Storage Oscilloscope DS-8617

p01-p26 00.9.28 2:07 PM ページ 23

Page 25: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

24

Specifications

B sweep delay (only in real-time mode)Delay time (A sweep sec/div) x from 0.2 to 10.2Delay jitter 1/20,000 or less (at A: 1 ms/div, B: 0.5 µs/div)

n Horizontal deflection system (X axis)HORIZ DISPLAY A, ALT, B, X-YA sweep

Sweep mode AUTO LEVEL, AUTO, NORM, SINGLESweep time Real-time mode: 10 ns/div – 500 ms/div

(with variable), 1-2-5 stepsAccuracy: ±2% at 8 div at the center of thescreenStorage mode: 10 ns/div – 5 s/div

B sweepDelay method Triggered after delayed, run after delayed Sweep time 10 ns/div – 20 ms/div, 1-2-5 steps

Sweep magnification X10 (fastest sweep time of 1 ns/div)

Rise time 3.5 ns (5 mV/div), calculated from rise time (ns) x bandwidth (MHz) = 350

Input coupling AC, DC, GNDInput RC Direct; 1 MΩ ±1.5%, 23 pF ±2 pF

When using SS-0130R probe;10 MΩ ±3%, 12.5 pF ±2 pF

Maximum input voltage Direct; ±400 V max.When using SS-0130R probe; ±600 V max.

Polarity switching Possible only for CH2, CH4n Triggering

Triggering modes NORMAL, TV, COUNT (Real time), EVENT(Storage)

n A triggeringSources CH1, CH2, CH3, CH4, LINE, VERTCoupling DC, HF REJ, LF REJ, AC, TV-V, TV-HPolarity +, –

n B triggeringTV triggering

Compatible systems NTSC, PAL/SECAM and HDTVLINE SEL 1 – 2000H

Event trigger Real-time mode: COUNT (1 – 65535 times,maximum count frequency of 20 MHz)Storage mode: COUNT, MISSING, BURST,EXTRA

n DelayData position (A sweep delay in storage mode)

Sensitivity Frequency bandwidth2 mV/div, 5 V/div, 10 V/div DC – 100 MHz, –3.5 dB5 mV/div – 2 V/div DC – 100 MHz, –3 dB

Memory length Maximum (div) Minimum (div)1k –10.24 +10.042k –20.48 +20.2832k –327.68 +327.48

n CRTShape 6-inch, rectangular, electrostatic deflectionEffective area 8 x 10 div (1 div = 10 mm)Vertical deflection system (Y axis)Display modes Real-time mode: CH1, CH2, CH3, CH4, ADDCH1, CH2, CH3, CH4

Sensitivity 2 mV/div – 10 V/div (with variable)Accuracy Real-time mode: ±2%

Storage mode: ±2% ±1/32 div, 2% increasedwith envelope

Frequency characteristicsIn real-time mode or with the equivalent sampling in storage mode

n Storage functionsA/D conversion

Resolution 8 bits (32 level/div, for full-scale CRT 8 div)Maximum sampling rate 100 MS/s, 4 channels simultaneously

Memory length 1 kwords/ch, 2 kwords/ch, 32 kwords/ch,switchable

External clock Clock signal input to CH4 using B trigger, upto 50 MHz

ModesEquivalent sampling Sweep time: 10 ns/div – 0.5 µs/divEnvelope Detection pulse width: 40 ns minimum

(indicated by at least 50% of originalamplitude)Sweep time: 20 µs/div – 5 s/div

Roll 4 channels can be operated simultaneouslyProcessing

Averaging Times: 2 – 256 timesSpeed: Approx. 72 times/s

MAX HOLD Times: 2 – 255 times and infinitySpeed: Approx. 80 times/s

Smoothing Moving average of (2n – 1) point before andafter data at each sampling point, n = 1 –20

Arithmetic operation CH1 ± CH2, CH3 ± CH4, CH1 x CH2, CH3 x between waveforms CH4

DisplayWaveform display memory 1 kword x 8 waveformsDisplay renewal speed Approx. 140 times/s (1 channel input, 1

ms/div, memory length of 1 kword)Interpolation function Pulse interpolation, linear interpolation, sine

interpolationWaveform Vertical axis: 250 times – 1/250 times around magnification/reduction GND

Horizontal axis: 1000 times – 1/1000 timesaround triggering point (A waveform) orscreen leftmost end (B waveform)

n X-Y operationX axis

Input Real-time mode: CH1Storage mode: CH1, REF1

Frequency bandwidth Real-time mode: DC – 3 MHz, –3 dBStorage mode: Same as CH1

Y axisInput Real-time mode: CH1, CH2, CH3, CH4, ADD

Storage mode: CH1, CH2, CH3, CH4,CALC1, CALC2, REF1, REF2, REF3, REF4

Phase difference Within 3° (DC – 100 kHz in real-time mode)n Measurements

Counter Measures A trigger frequency 10 Hz – 100MHz, 4-digit indication, measurement error of ±10counts

n Copy output (in storage mode only)Interface Printer output via Centronics and plotter

output via the specified interface (option)Output data Waveforms, cursors, scale, readout

n Interface GP-IB, Centronicsn Data storage Backed up by built-in batteries

Type of stored data Setup, waveform data, commentNumber of stored data Possible to store 149 setups, 149 comments,

49 waveforms (1 kword), 29 (2 kwords),2 (32 kwords)

n Power supplyVoltage range AC 90 V – 250 VFrequency range 48 Hz – 440 HzPower consumption Approx. 200 W, max. (with AC 100 V)

n Dimensions and weightDimensions Approx. 320(W) x 160(H) x 423(L) mmWeight Approx. 11 kg

n Accessories Power cord (1), probe SS-0130R (2), fuse(2), panel cover (1), accessory bag (1),instruction manual (1)

p01-p26 00.9.28 2:07 PM ページ 24

Page 26: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

25

n Portability With a total weight of only about 3 kg (including the printer), thiscompact scope is easy to carry and fits easily into narrow spaces oncrowded workbenches.

n High-speed sampling rate and longmemory

The DS-8812 operates at 500 MS/s sampling rate with 100 MHzfrequency bandwidth. Each channel has a long 100k-word acquisitionmemory.

n Built-in printerDisplay data or waveform data can be printed out on the built-inprinter.

n Optimum design for DSO beginners With a variety of interfaces and triggers provided, this scope can beconnected to a wide selection of external devices. The wide choice ofsignal outputs is something only possible with a digital oscilloscope.

n Help menuExplains the various menu functions (shown in reverse). This menuis useful if a user needs to know what a particular function does.Four display modes (English, Japanese, traditional Chinese,simplified Chinese) are available.

Digital Storage Oscilloscope DS-8812

GP-IB RS-232C

Floppydisk

PCMCIAcard

Built-in printer

Printer interface

System flexibilityA built-in PCMCIA card slot and floppy disk drive are provided soyou can save measurement data direct to a PCMCIA card orfloppy disk and print it out as needed using either the built-inprinter or an external printer via the printer interface. GP-IB(optional) and RS-232C interfaces are also provided, letting youcontrol the scope via a personal computer.

(optional)

n Event triggerA wide range of triggers are available, including event triggers(count/burst/extra/missing) and TV triggers (NTSC, PAL/SECAM).

n Hardware 5-digit frequency counterInput signal frequency can be shown in five digits, making aliasingdisplay checking easier.

n Various automatic measurementsAll the basic automatic measurement functions required for commonmeasurements are provided, assuring quick, accurate results andimproving efficiency.

n 25 GS/s equivalent samplingUsing the equivalent sampling method, the time resolution isincreased up to 40 ps (equivalent to 25 GS/s). Waveforms can beobserved before triggering.

Help menuMenu

selectionTraditional Chinese mode Simplified Chinese mode

DC – 100 MHz, 2 CH, 500 MS/s

p01-p26 00.9.28 2:07 PM ページ 25

Page 27: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

n Vertical CH1, CH2Sensitivity 2 mV/div – 10 V/div (1-2-5 steps),

(0.8 mV/div zoomed)Accuracy ±2%Frequency Bandwidth (From 10 Hz at AC coupling)

2 mV – 10V/div DC – 100 MHz, –3 dBBandwidth Limiter DC – 10 MHz (CH1, CH2 can be set

individually)Input coupling AC, DC, GNDInput RC 1 MΩ ± 1.5%// 20 pF ± 2 pFMaximum input voltage ±400 V DC + AC peak.Probe sense AUTO, Manual (1:1, 10:1, 100:1, 1000:1)Rise time Approx. 3.5 ns

Note: Calculated from the following formula

Offset voltage

n TriggeringTrigger mode EDGE, EVENT, TVSource CH1, CH2, EXT, LINECoupling DC, AC, HF-REJ, LF-REJ Slope +, – Sensitivity

Event trigger COUNT, BURST, MISSING, EXTRATV trigger

Format NTSC, PAL/SECAMTV–V ODD, EVEN, BOTH (line number selectable)TV–H

n HorizontalA sweep

Sweep mode AUTO, NORMAL, SINGLESweep rate 5 ns – 50 s/div (1-2-5 sequence)

Trigger delay

–500s ~ +750 s (fixed) when waveform acquisition stops Hold off 200 ns – 2 s, OFF

n Storage functionsA/D converter

Acquisition memoryShort memory 5 k words/chLong memory 100 k words/ch

Storage mode Normal, Equivalent Sampling, Peak detect,Average, Roll

Waveform processingAverage 2 – 256 times

26

Specificationsn Display functionsDisplay 5.8-inch high contrast LCD display, 320 x

240dots (high brightness backlight EL)Waveform display Waveform display area of 8 x 10 divDot join On, OffPersistence (infinity only) On, OffArithmetic functions +, –, xX–Y display X = CH1, Y = CH2Reference waveform Up to 10 tracesScale type Frame, axes, gridComment display AvailableHelp function English/Japanese, Chinese (Simplified,

Traditional) selectable

n Waveform storageRef. Save/clear Ref. save and clear functions are available with

individual key (internal memory only)Setup save/clear, undo Setup data save, clear and undo functions are

available with individual key (internal memoryonly)

Save and recallMedia ATA card, floppy disk (3.5-inch)Data type Setup data, waveformNumber of record ATA: Max. 9999

Floppy: Max. 200Record format Binary/ASCII format are available for waveform

dataComment AvailableAuto copy Waveform data can be automatically stored

when the waveform is triggered (ATA card,floppy disk, built-in printer)

n Other functionsAuto setup Automatically setup V, H range and trigger for

repetitive signalCursor measurement ∆V, ∆t (1/∆t), V at tAutomatic measurement

Channels CH1, CH2Items Tr, Tf, Vrms, Vmean, f, T, +PW, –PW,

Duty,+Peak, –Peak, P-P, SkewSimultaneous Four (4) items

Frequency counterDisplay digit 5 digitsAccuracy ±0.01%Frequency range 1 Hz - 100 MHz

Interface RS-232C, GP-IB (option)RS-232C

Baud rate 2.4 k, 4.8 k, 9.6 k, 19.2 k, 38.4 k, 57.6 k, 115.2 kData bit 7, 8-bitParity NoneDelimiter LF or CR/LF

Data output Built-in printer, Floppy disk (3.5-inch), ATA cardCentronics

Built-in printer Type Line thermal printerPaper width 80 mmRoll print Available

Floppy, ATA cardOutput format TIFF, BMP

Centronics DPU-414, ESC-P09, ESC-P24, PC-PR201Output format TIFF, BMP

Calibration signalWaveform Square waveOutput voltage 0.6 V ± 1%Frequency 1 kHz ± 0.01%

n Power supplyVoltage range AC 100 – 240 VFrequency 50 – 60 HzPower consumption 90 VA max. (with built-in printer operation)n Dimensions & weightDimensions Approx. 215 (W) x 170 (H) x 166 (L) mmWeight Approx. 3.0 kg excluding accessoriesn Accessories Power cord (1 ), probe (SS-0130R x 2), fuse (2),

roll paper (1 ), instruction manual (1 ),

350Tr = [ns]

Bandwidth [MHz]

Vertical range Offset voltage2 mV/div – 50 mV/div ±1 V0.1 V/div – 0.5 V/div ±10 V

1 V/div – 5 V/div ±100 V

Frequency bandwidth CH1, CH2 EXTDC – 10 MHz 0.5 div 50 m Vp-p10 MHz – 100 MHz 1.5 div 150 m Vp-p

Memory length Sweep time Set rangeShort 5 ns/div ~ 1 ms/div –5 div ~ +10 ms

2 ms/div ~ 50 s/div –5 div ~ +500sLong 5 ns/div ~ 20 ms/div –5 div ~ +200 ms

50 ms/div ~ 50 s/div –5 div ~ +500s

Maximum sampling rate simultaneous for two channelsResolution Max. sampling Peak detect8-bit 500 MS/s 250 MS/s

p01-p26 00.9.28 2:07 PM ページ 26

Page 28: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

27

Max. 1 GHz, max 112 CH, 65536bits/ch

The SL-4650/4651 are upgraded versions (1 GHz) ofthe SL-4640A/4641A series. With asynchronousmeasurement, the maximum sampling rate is 1 GHzwith 16 CH (8 CH with 1 GHz clock rate) and 65536bits/ch. Optional 100 MHz (async measurement), 48CH or 40 MHz (sync measurement), 96 CHcapabilities can be added, allowing 8-bit to 32-bitµP disassemble support and 4-time axis display.Superior performance and expandability plusdigital storage scope functions such as max. 200MS/s, 2 CH make these multi-purpose analyzersideal for professional use.

Max. 400 MHz, max. 112 CH, 16384bits/ch

The SL-4640/4641 have a maximum sampling rateof 400 MHz, 16 CH and 16348 bits/ch. Optional 100MHz (async measurement), 48 CH or 40 MHz (syncmeasurement), 96 CH capabilities can be added,allowing 8-bit to 32-bit µP disassemble support and4-time axis display. Superior performance andexpandability plus digital storage scope functionssuch as max. 200 MS/s, 2 CH make these multi-purpose analyzers ideal for professional use.

100 MHz, 16 CH, 4096 bits/ch

Rapid developments in digital equipment such asmicroprocessors (µP) make it important thattroubleshooting equipment designed to cope withthe unique problems peculiar to digital systems beflexible and up-to-date. With the SL-4122 — whichoffers a sampling rate of 100 MHz (10 ns), 16 CHand 4096 bits/ch, you can choose from eitherparallel data analysis or serial data analysis. At thesame time, you can automate your troubleshootingprocedures with the convenient remote controlfunction.

SL-4650/4651

SL-4640A/4641A

SL-4122

Logic Analyzers SL-4650/4651/4640A/4641A/4122

p27-p29 00.9.28 2:43 PM ページ 27

Page 29: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

28

Model names SL-4651 SL-4650 SL-4641A SL-4640A SL-4122

1 GHz/8 CH65536 bits/ch500 MHz/16 CH32768 bits/ch200 MHz/16 CH16384 bits/chOPTSL-233

50 MHz/48 CH,100 MHz/24 CH,4096 bits/ch

SL-233 – 23450 MHz/96 CH,100 MHz/48 CH,4096 bits/ch

2 ns at 200 MHz

400 MHz/8 CH200 MHz/16 CH16384 bits/ch

OPTSL-233

50 MHz/48 CH,100 MHz/24 CH,4096 bits/ch

SL-233 – 23450 MHz/96 CH,100 MHz/48 CH,4096 bits/ch

3 ns at 200 MHz

400 MHz/8 CH200 MHz/16 CH16384 bits/ch

OPTSL-23350 MHz/48 CH, 100MHz/24 CH, 4096bits/chSL-233 – 23450 MHz/96 CH, 100MHz/48 CH, 4096bits/ch3 ns at 200 MHz

100 MHz/16 CH50 MHz/32 CH4096 bits/ch

10 ns (at 50 MHz)

OPTSL-233

40 MHz/48 CHSL-233 + SL-234

40 MHz/96 CH4096 bits/ch100 MHz timingMeasurable

OPTSL-233

40 MHz/48 CHSL-233 + SL-234

40 MHz/96 CH4096 bits/ch100 MHz timingMeasurable

OPTSL-233

40 MHz/48 CHSL-233 + SL-234

40 MHz/96 CH4096 bits/ch100 MHz timingMeasurable

10 MHz/32 CH

4096 bits/CH

Analog waveform measurementClock/channel

Memory lengthResolution

OPT

SL-232200 MHz/ 1 CH100 MHz/2 CH8192 words/CH8 bits

OPT

SL-232200 MHz/ 1 CH100 MHz/2 CH8192 words/CH8 bits

OPT

SL-232200 MHz/ 1 CH100 MHz/2 CH8192 words/CH8 bits

Measurement and results 4 types of timing,states (2 analyzers),and analogwaveforms aresimultaneouslymeasured anddisplayed in relationto time.

4 types of timing,states (2 analyzers),and analogwaveforms aresimultaneouslymeasured anddisplayed in relationto time.

Display switchablebetween timing andstate display.

Microprocessorsystem, 8 - 32-bitsystem, interfacebus system, GP-IB,SCSI

Microprocessorsystem, 8 - 32-bitsystem, interfacebus system, GP-IB,SCSI

Microprocessorsystem, 8 - 32-bitsystem, interfacebus system, GP-IB,SCSI

Microprocessorsystem, 8 - 32-bitsystem, interfacebus system, GP-IB,SCSI

Microprocessorsystem, 8-bitsystem, interfacebus system, GP-IB

OPT OPT OPT OPT OPT

Battery backup function Data, setupconditions

Data, setupconditions

Data, setupconditions

Data, setupconditions

Data, setupconditions

External recording media Memory card Memory card Memory card Memory card —

Display Color Monochrome Color Monochrome Monochrome

External color CRT output Digital RGBAnalog RGB

Digital RGBAnalog RGB

Digital RGBAnalog RGB

Digital RGBAnalog RGB

Digital RGB

Interface

Remote control GP-IBRS-232-C

GP-IBRS-232-C

GP-IBRS-232-C

GP-IBRS-232-C

OPTSL-233

40 MHz/48 CHSL-233 + SL-234

40 MHz/96 CH4096 bits/ch100 MHz timingMeasurable

4 types of timing,states (2 analyzers),and analogwaveforms aresimultaneouslymeasured anddisplayed in relationto time.

VideooutputParallelGP-IBRS-232-C

Standard

VideooutputParallelGP-IBRS-232-C

Standard

VideooutputParallelGP-IBRS-232-C

Standard

VideooutputParallelGP-IBRS-232-C

StandardParallelGP-IBRS-232-C

Standard Videooutput

OPT

OPT

Major features and performance

1 GHz/8 CH65536 bits/ch500 MHz/16 CH32768 bits/ch200 MHz/16 CH16384 bits/chOPTSL-233

50 MHz/48 CH,100 MHz/24 CH,4096 bits/ch

SL-233 – 23450 MHz/96 CH,100 MHz/48 CH,4096 bits/ch

2 ns at 200 MHz

State (sync) measurementExternal clock/channel

Memory lengthOthers

Timing (asynchronous) measurement

Internal clock/channelMemory length

Glitch detection ability

OPT

SL-232200 MHz/ 1 CH100 MHz/2 CH8192 words/CH8 bits

4 types of timing,states (2 analyzers),and analogwaveforms aresimultaneouslymeasured anddisplayed in relationto time.

Disassemble support (mnemonicdisplay) probe, software are optional.

Serial data analysis

GP-IBRS-232-C

p27-p29 00.9.28 2:43 PM ページ 28

Page 30: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

29

Table for SL-4650/4651/4640A/4641A options

: Asynchronous measurement 1 GHz/500 MHz, 8/16 CH

(SL-4650/4651), 400/200 MHz, 8/16 CH

(SL-4640A/4641A)

A

+ serial data (RS-232-C) analysis (simultaneous analysis fortransmission and reception)

SL-4650/4651(SL-054 x 2)

SL-4640A/4641A(SL-047 x 2)

+ SCSI analysis

+ 6809/E analysis

+ 6800/02 analysis

+ 8086 analysis

+ 80286 analysis

+ 68000/10 analysis

+ 8085A analysis

+ Z-80 analysis

+ GP-IB analysis

Main unit Acquisition Disassemble Personalitymodule software probe

Basic acquisitionmodule SL-233

(SL-037 x 3)

SL-814

SL-038

SL-039

SL-040

SL-041

SL-042

SL-043

SL-044P

SL-045

SL-051

SL-050

SL-815

SL-816

SL-817

SL-821

Add-onacquisition

module SL-234

(SL-037 x 3)

SL-818 SL-046

SL-050

+ 68020 analysis

: analog waveform measurement (2 CH)

+ serial data (RS-232-C) analysis (either transmission or reception)

AnalogAcquisition

module1

1

1

1

1

1

1

1

1

1

1

1

1

1

4

4

4

4

4

4

4

4

4

4

4

4

4

4

4B A: + 48 CH async (50 MHz)/sync (40 MHz) measurementor 24 CH async (100 MHz) measurement

B

B

B

B

B

B

B

B

B

C

C

C

C A: + 96 CH async (50 MHz)/sync (40 MHz) measurementor 48 CH asynchronous (100 MHz) measurement

D+

D+

D+

D+

D+

D+

D+

D+

D+

D+

D+

D+

D+

D+

SL-23221170-06-66(SS-0042 x 2)

D+

1

SL-4122 options Async measurement

100 MHz, 16 CH, 4096 bits/ch,50 MHz, 32 CH, 4096 bits/ch

Sync measurement10 MHz, 32 CH, 4096 bits/ch

GP-IB analysis display External monitor output

(composite + color)

Main unit SL-4122(provided with 2 SL-028)

Serial data analyzer and interface SL-501

4-ch clock qualifier probe SL-035

SL-038 GP-IB personality probeSL-039 Z80 personality probeSL-040 8085A personality probeSL-041 6809 personality probeSL-042 6800/02 personality probe

Serial dataanalysis

Remote control(GP-IB, RS-232C)

Hard copy(graphic printer)

4

4

p27-p29 00.9.28 2:43 PM ページ 29

Page 31: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

30

Soft magnetic parts made of ferrite play important rolein electric components as they are used in a broadscope of applications ranging from lower frequenciessuch as yokes for micromotors, to high frequenciessuch as flyback transformers, deflecting yokes, high-frequency transformers and magnetic heads.In actual operation, these magnetic parts displaycharacteristics different from direct current magneticcharacteristics or characteristics measured with anLCR meter.

IWATSU’s Ultrawide-bandwidth B-H Analyzers are designed to meethigh-performance requirements for various applications related tothe research, development and inspection of soft magnetic materials.

n Core loss measurementHigh-frequency transformers used in switching power supplies andDC-DC converters suffer current leakage, which increases as thehandled frequency increases. The causes of the leakage includehysteresis loss and eddy-current loss. The heat generated by lostcurrent causes the temperature of the equipment to rise, making itdifficult to reduce the size of equipment. Measuring core loss of softmagnetic parts provides the best solution to minimizing loss andenabling further reductions in equipment size.

n B-H curve measurementRapid progress has been made in production of magnetic heads andthin-film sensors. However, no systems for measuring the B-H curvein the high-frequency domain have been available. Until now,measurement of thin-film materials has been done using DC B-Hcurve measurement by VSM or µ-measurement by LCR meters. TheSY-8232 and SY-8217 B-H analyzers are equipped with a thin-filmmeasurement function for use in measurement of high-frequency B-Hcurves of thin films. As a result, more accurate analysis of thin-filmmaterials is now possible.

n Permeability measurementYoke materials used in motors, actuators and relays are usually madeof silicon steel, soft iron, permalloy and stainless steel. However,these materials tend to cause differences in magnetic characteristicsaccording to the processing and heat treatment.The B-H analyzers are capable of measuring the magneticcharacteristics of these parts, providing data that will facilitateimprovement of these materials.As for ordinary ferrite cores, the B-H analyzer can measureinductance characteristics (SY-8232) and m-characteristics.

<Development system>All IWATSU’s magnetic characteristic measurement instruments aredeveloped using our original analog technologies, extensive fieldexperience, and by anticpating and responding to user demands.

10 Hz (1 Hz option) ~ 10 MHzSY-8232

10 Hz ~ 5 MHzSY-8217

Simplified type50 Hz, 60 Hz ~ 100 kHz

SY-8101

Automatictemperature characteristicmeasurementsystem

n Options

SY-922Pulse Generator

SY-924Thin Film Measurement Pod

SY-931 DC Bias Power Supply

SY-928 Expansion Pod

SY-927 High-Frequency,

High-Sensitivity Pod

SY-943 Pulse Generator

SY-937 Single PlateMeasurement

System

Model Measuring Frequencies Major Applications

SY-8232

SY-8217

SY-8101

10 Hz to 5 MHz

R&D of magnetic heads, power ferrite,ultrathin amorphous plates, etc.

AC magnetic characteristicmeasurement of magnetic materialsand parts for use in switching powersupplies, DC-DC converters, etc.

Development & inspection of magneticcores for high-frequency power andmicromotor yokes. Substitution for a U-function meter in core lossmeasurement.

50 Hz, 60 Hz to 100 kHz

10 Hz (1 Hz option) to10 MHz

B-H ANALYZER SELECTION GUIDE

p30-p40 00.9.28 2:46 PM ページ 30

Page 32: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

31

The SY-8232 high-frequency B-H analyzer is theflagship of IWATSU’s line of B-H analyzers. It has ahigh-frequency B-H curve tracing capability over anultrawide-range measurement frequency from 10Hz (optionally 1 Hz) to 10 MHz.The SY-8232’s compact design makes it ideal fordesktop use. It incorporates features required formeasuring high-frequency magnetic characteristics,including an oscillation circuit, power amplifiercircuit, high-speed digitizer, operation control circuitand a printer.The built-in 25 VA power amplifier allows directmeasurement of small specimens such as magneticheads, while use of an external power amplifierenables measurement of large amplitudecharacteristics and saturation characteristics ofpower ferrite or ultrathin amorphous materials. Thelower limit frequency is as low as 10 Hz (optionally1 Hz), permitting the measurement of near DCmagnetic characteristics of soft magnetic materials.As the analyzer allows both near DC and AC, themeasurements of coercive force (Hc) related tomagnetic wall production, migration and extinctioncan be more effective and research and testing inmaterials development can be performed morequickly.

The standard of B-H Analyzer.The top model of IWATSU B-H Analyzers.

n Ultrawide measurement frequencybandwidth

The frequency range for measurement is exceptionally wide,from 10 Hz (optionally 1 Hz) to 10 MHz.

n Desktop size, all-in-one constructionA compact design incorporating an oscillation circuit, power amplifiercircuit, high-speed digitizer, operation control circuit and printer.Magnetic head material can be directly measured by the built-inpower amplifier (25 VA) for excitation. (An optional external poweramplifier can also be used.)

n Continuous measurement function andan extensive selection of othermeasuring functions

Continuous measurement with up to 12 steps, and variousmeasurements including a B-H curve, core loss curve, µ-characteristics and L-characteristics, are available.

n High-speed, high-precisionmeasurement

High-speed measurement in approx. 3 seconds can be performed. Inaddition, an FFT arithmetic circuit permits automatic compensationand calibration of frequency characteristics, enabling high-precisionmeasurements.

n Printer provided as standard (built-in)Measurement results can be printed out immediately. Convenient fordata sorting.

n GP-IB interface provided as standardAn automated measurement system in combination with a PC can beconfigured.

n Easy-to-view 9-inch color CRT display

n Easy operation with pop-up menusystem

Pop-up menus are displayed on the CRT to facilitate operation.Results are displayed as graphs or lists.

n Enhanced measurement efficiency witha wide range of options

Options include an external power amplifier and sample connectionpod for various use.

SY-8232 with SY-924 (Option)10 Hz (1 Hz Option) to 10 MHz

B-H Analyzer SY-8232

p30-p40 00.9.28 2:46 PM ページ 31

Page 33: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

32

Measurement modesCore loss measurement: Frequency (f) or maximum magnetic flux density

(Bm) can be varied.B-H curve measurement: Frequency (f) or maximum magnetic field (Hm) can

be varied.Permeability measurement: Frequency (f) can be varied.

Measured itemsCore loss measurement: Max. magnetic flux density (Bm), residual magnetic

flux density (Br), max. magnetic field (Hm), coercive force (Hc), coreloss (Pc, Pcv, Pcm), phase (θ), amplitude permeability (µa), hysteresisloss (Ph), eddy-current loss (Pe).

B-H curve measurement: Max. magnetic flux density (Bm), residual magneticflux density (Br), max. magnetic field (Hm), coercive force (Hc), coreloss (Pc, Pcv, Pcm), phase (θ), amplitude permeability (µa),differential permeability (µdiff), square ratio (Br/Bm), total magneticflux change (2φ m)

Permeability measurement: Max. magnetic flux density (Bm), max. magneticfield (Hm), core loss (Pc), phase (θ), amplitude permeability (µa),inductance (L), complex permeability (µ’, µ”).

Operation modesSingle: One measurement step with one operation.Continuous: Up to 12-step preset schedules (frequencies or amplitudes) can

be measured continuously with one operation.Set frequency

10 Hz (optionally 1 Hz) to 10 MHz, 2 digits effectiveAccuracy: ±0.1% for the set value.

Measurement accuracy (23°C ±5°C )*

H amplitude measurement (dH):

B amplitude measurement (dB):

Phase accuracy (dθ):

n Core loss measurement of transformersfor high-frequency power supplies

R&D of magnetic heads, power ferrite, ultrathin amorphous materials, etc.

When an EI core FE122 is measured with the above combination, the following measurements are available.At 1 MHz, max. 100 mT (millitesla): Windings = 5.At 3 MHz, max. 50 mT (millitesla): Windings = 3.

Excitation sectionOutput voltage ±50 V max., output current ±1 A max. ( 1.1 kHz) or ±4 A max. (10 Hz (optionally 1 Hz) to 1 kHz).Output impedance 1 Ω + 0.1 µH, output power 25 VA.

Detection section (standard)Excitation current detectionSystem: Voltage drop across two ends of non-inductive

resistance.Detection sensitivity: ±50 mA to ±5 A (1-2-5 steps)Frequency bandwidth: DC to 100 MHzMagnetic flux detection System: Detection of voltage (induced voltage) across

two ends of detection coil.Detection sensitivity: ±50 mA to ±50 V (1-2-5 steps)Frequency bandwidth: DC to 100 MHz

Storage sectionSampling rate: 512 times the set frequency (synchronized with

the built-in oscillator).Resolution: 16 bits

Display sectionSystem: 9-inch color CRTContents: Measuring condition, characteristic values, B-H

curve, characteristic graphsPrinter (Built-in)

Heat-sensitive dot line system. Paper width approx. 112 mm, printing time nomore than approx. 5 sec.

External interfaceGP-IB interface

Power supply100 V AC (90 ~ 132 V) or 200 V AC (180 – 250 V) models. Approx. 800 W (100 V AC)

Dimensions & weightMain unit: Approx. 420W x 350H x 520L mm (excluding the pod),

approx. 34 kg (SY-8232 mainframe + SY-301 measurement unit)Environment

Operating temperatures +5°C to +35°C (+10°C to +30°C when the printer isused)

Performance guaranteed temperatures+18°C to +28°C

Provided accessoriesSY-921 measurement pod (1 set), power cords (2), connection cables (1 set),estimation samples (1 set), adapters for calibration (1 set), Thermal paper (2rolls), fuses (4), instruction manual (1), dust cover (1), accessory case (1).

By combining the SY-8232 B-H analyzer with the GB-12145 power amplifier (optional), core loss up to 3 MHzcan be measured.* GB-12145 will be alternated with IE-1125 on and after the 2nd half

of 2000.

Measurement timeApprox. 3 sec./step (when the measured frequency is 1 kHz or more)

Oscillating sectionOscillation frequency: 10 Hz to 10 MHz, sine waveOutput voltage/resistance: 0 to ±2.5 V/50 ΩBuilt-in excitation control in 3 steps of approximate value, asymptotic anddemagnetization.

VF±(2% + 0.2% x ( – 1))**Vr

VF IF±(0.15° + 0.07° x ( + – 2) + 0.02°)**Vr Ir

IF±(2% + 0.2% x ( – 1))**Ir

* Defined as the basic accuracy. Themeasurement accuracy may differ dependingon the D.U.T. and the measuring condition.For details, please contact to Iwatsu.

** · VF, IF : Amplitude of Full scale· Vr, Ir : Amplitude of Reading

Specifications

Major Applications

Example of Combination

p30-p40 00.9.28 2:46 PM ページ 32

Page 34: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

33

The SY-8217 measures themagnetization characteristics of softmagnetic materials with high accuracyand in a short time over a widefrequency range from 10 Hz to 5 MHz. Itis a powerful tool for research,development, manufacturing andinspection of low-loss magneticmaterials for use in compact motoryokes, flyback transformers for TV, high-frequency power transformer, etc.Incorporating an oscillator formeasurements and digitizer in acompact, desktop type cabinet, the SY-8217 is the ideal repalcement for anexisting U-function meter as thestandard tool for core lossmeasurement.

B-H curve measurement over 10 Hz to 5 MHz.The standard core loss measurement tool toreplace U-function meters.

n Wide measurement frequencybandwidth

The frequency range for measurement ranges from 10 Hz to 5 MHz.

n High-precision measurementAn FFT arithmetic circuit permits automatic compensation andcalibration of frequency characteristics of the measurement system.

n High-speed measurementHigh-speed measurement can be performed in approx. 3 seconds,considerably improving measurement efficiency.

n Compliance with JIS C2514, JIS H7153and EMAS 5003.

Ideal for estimation of everything from yoke materials for compactmotors to the materials for high-frequency transformers.JIS C2514: E-shaped ferrite core.JIS H7153: High-frequency core loss test method for amorphous

metallic cores.EMAS 5003: Test method for ferrite cores of power applications.

n Color TFT displayThe bright color TFT display shows the characteristic values, B-Hcurves and excitation waveforms simultaneously.

n Printer and 3.5-inch FDD provided asstandard

The measurement results can be printed out immediately. Convenientfor data sorting. The results can also be output to a 3.5-inch floppydisk in the csv format, then loaded in a PC and sorted usingtabulation software.

n GP-IB interface provided as standardAn automated measurement system can be constructed witha PC.

n Compact, desktop size(Rack mountable)

n Easy operationSimple and easy to use design.

10 Hz to 5 MHz

B-H Analyzer SY-8217

p30-p40 00.9.28 2:46 PM ページ 33

Page 35: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

Measurement methodCross power spectrum method

Measurement modesCore loss measurement: Frequency (f) and maximum magnetic flux density

(Bm) can be set.B-H curve measurement: Frequency (f) and maximum magnetic field (Hm)

can be set.Measured items

Core loss measurement: Max. magnetic flux density (Bm), residual magneticflux density (Br), max. magnetic field (Hm), coercive force (Hc), coreloss (Pc, Pcv, Pcm), phase (θ), amplitude permeability (µa).

B-H curve measurement: Max. magnetic flux density (Bm), residual magneticflux density (Br), max. magnetic field (Hm), coercive force (Hc), coreloss (Pc, Pcv, Pcm), phase (θ), amplitude permeability (µa),differential permeability (µdiff), square ratio (Br/Bm), total magneticflux change (2φ m), complex permeability (µ’, µ’’ )

Operation modesSingle: One measurement step with one operation.

Set frequency10 Hz to 99 Hz, 2 digits effective100 Hz to 5 MHz, 3 digits effectiveAccuracy: ±0.1% for the set value.

Measurement accuracy (23°C ±5°C)*

H amplitude measurement (dH):

B amplitude measurement (dB):

Phase accuracy (dθ):

Core loss measurement (dPc):

Measurement timeApprox. 3 sec./step (when the measured frequency is 1 kHz or more)

34

Development and inspection of high-frequency power cores, micromotor yokes, etc. Core loss measurement by replacing a U-function meter. Manufacturing and inspection of amorphous thin films and amorphous cores.

Oscillating sectionOscillation frequency: 10 Hz to 5 MHz, sine waveOutput voltage/resistance: 0 to ±2.5 V/50 ΩBuilt-in excitation control in 3 steps of approximate value, asymptotic anddemagnetization.

Detection section (standard)Excitation current detectionSystem: Voltage drop across two ends of non-inductive

resistance.Detection sensitivity: ±5 mA to ±5 A (1-2-5 steps)Frequency bandwidth: DC to 50 MHzMagnetic flux detectionSystem: Detection of voltage (induced voltage) across

two ends of detection coil.Detection sensitivity: ±5 mV to ±200 V (1-2-5 steps)Frequency bandwidth: DC to 50 MHz

Storage sectionSampling rate: 512 times the set frequency (synchronized with

the built-in oscillator).Resolution: 16 bits

Display sectionSystem: Color 8.4-inch TFTContents: Measuring condition, characteristic values, B-H

curve, excitation current and induced voltagewaveforms

Printer (Built-in)Heat-sensitive dot line system. Paper width approx. 112 mm, printing time nomore than approx. 5 sec.

Floppy disk drive3.5-inch FDD (DOS format)

External interfaceGP-IB interface

Power supply100 to 240 V AC, approx. 400 VA (when the built-in printer is running)

Dimensions & weightMain unit: Approx. 420W x 266H x 480L mm (excluding the pod), approx. 17 kg

EnvironmentOperating temperatures +5°C to +35°C (+10°C to +30°C when the printer is used)

Performance guaranteed temperatures+18°C to +28°C (after power on 60 min.)

Provided accessoriesMeasurement pod (1 set), power cord (1), sample cores (1 set), adapters forcalibration (1 set), thermal paper (2 rolls), fuses (2), instruction manual (1),dust cover (1), accessory case (1).

For R&D

For manufacturing& inspection

For automatedtemperaturemeasurement

B-H analyzer SY-8217

B-H analyzerSY-8217

B-H analyzerSY-8217

Power amplifierIE-1119

Power amplifierIE-1125

Power amplifierIE-1125

Data filing option (3.5” FDD and software)

IE-833

Scanner (with oven)

IE-1123, IE-832, No controller including a

PC is required.

+

+

+

+

+

Power amplifier

* Defined as the basic accuracy. Themeasurement accuracy may differ dependingon the D.U.T. and the measuring condition.For details, please contact to Iwatsu.

Specifications

Major Applications

Example of Combination

VF= ±(1% + 0.2% x ( – 1))**Vr

IF VF= ±(0.1° + 0.05° x ( + – 2) + 0.01°)**Ir Vr

IF= ±(1% + 0.2% x ( – 1))**Ir

π= ±3.5% ±( | dH | + | dB | + | x dθ x tanθ | x 100)%180°

** · VF, IF : Amplitude of Full scale· Vr, Ir : Amplitude of Reading

p30-p40 00.9.28 2:46 PM ページ 34

Page 36: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

35

Simplified B-H analyzer is ideal forproduction line monitoring or training.

n Measurement frequency bandwidth50 Hz, 60 Hz to 100 kHz

n Excitation current (from built-in poweramplifier)

2A (max.) (An external power amplifier can be connected.)

n GP-IB connection with a controller PC(required)

The measurement is executed by the controller PC, and the resultsare shown on the PC display.* The GP-IB cable, GP-IB interface card and controller PC are not included in the product.

n Continuous measurement at approx. 2-sec. intervals using the high-speedmeasurement (optional)

AC magnetic characteristic measurement of magnetic materials and parts for use inswitching power supplies, DC-DC converters, etc.

In combination with the single-plate magnetic characteristic measurement system (SY-937): AC magnetic characteristic measurement of thin plate materials such aselectromagnetic steel.

In combination with the high-speed measurement function (optional): Incorporation ofan automatic tester for continuous measurement at about 2-sec. intervals.

Method Waveform storage methodMeasurement frequencies 50 Hz, 60 Hz to 100 kHz (1-2-5 steps)Oscillating section

Oscillation frequency: 50 Hz, 60 Hz to 100 kHz (1-2-5 steps)Frequency accuracy: ±0.1%Output waveform: Sine wave (Built-in asymptotic

excitation/demagnetization control)Output amplitude: Max. ±3 V ±3%Output impedance: 50 Ω ±2%Output connector: SMA receptacle (jack)

Built-in power amplifierOutput current: Max. ±2 A ±3%Output amplitude: Max. ±30 V ±3%Output impedance: (1 Ω ±2%), (0.1 µH ±2% at 1 kHz)Input connector: SMA receptacle (jack)Output connector: BNC receptacle (jack)Amplifier selection: Built-in or external power amplifier can be

selected according to the connection method.Excitation current detection

System: Voltage drop across two ends of non-inductiveresistance.

Non-inductive resistance: 1 Ω ±0.5%Sensitivity: ±50 mA to ±5 A (1-2-5 steps), auto range

Induction voltage detection System: Voltage across two ends of secondary coilDetection sensitivity: ±50 mV to ±50 V (1-2-5 steps), auto range

Measurement modesCore loss measurement: Measurement by specifying the frequency (f)

and max. flux density (Bm)B-H curve measurement: Measurement by specifying the frequency (f)

and max. magnetic field (Hm)

Measurement items (Displayed on the controller PC)Waveforms: Excitation current waveform, i(t), (256 points/interval)

Total magnetic flux waveform, N2φ(t), (256 points/interval)Induced voltage waveform, V2(t), (256 points/interval)Magnetic flux density waveform, B(t), (256 points/interval)B-H curve

Characteristic values: Max. magnetic field (Hm), coercive force (Hc),max. magnetic flux density (Bm), residual fluxdensity (Br), square ratio (Br/Bm), total magneticflux change (2φ m), core loss (Pc, Pcv, Pcm),amplitude permeability (µa), phase angle (θ).

External interface GP-IB interface (standard) (for connection withthe controller PC)

Power supply 100 V AC ±10%, 50/60 HzDimensions & weight Approx. 430W x 150H x 450L mm (excluding

projections), approx. 8kgOperating temperatures +58 C to +358 C, 85%RHSample connection pod Approx. 180W x 60H x 100L mm (excluding

projections), approx. 0.6kgProvided accessories Power cord (1), 3 A fuses (2), pod cover (1), AC

couple module (1), BNC-BNC cable 120 cm (1),BNC-SMA cable 100 cm (1), SMA-SMA cable12 cm (1), IE-512 test adapter (1), instructionmanual (1), control program (3.5” 2HD disks)(2), control program manual (1), rack-mount L-brackets (2), rackmount L-bracket mountingscrews (8), accessories list (1), sample cores(1 set), accessory case (1).

(A PC and GP-IB cable/interface card are optional.)

50 Hz, 60 Hz to 100 kHz

Specifications

Major Applications

B-H Analyzer SY-8101

p30-p40 00.9.28 2:46 PM ページ 35

Page 37: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

36

NamesModel

Applications/SpecificationsApplicable Analyzers

Names SY-8232 SY-8217 SY-8101

Used to estimate pulse exciting characteristics of transformers for switching power supplies, materials

Pulse excitation measurement functionSY-502 for solenoid valves, relays, injectors and step motors. Adds sync pulse output signals to a B-H Yes

analyzer SY-8232 (Can be connected to a user’s drive circuit.)

Used to estimate pulse exciting characteristics of transformers for switching power supplies, materialsIE-514* for solenoid valves, relays, injectors and step motors. Adds sync pulse output signals to a B-H Yes

analyzer SY-8217 (Can be connected to a user’s drive circuit.)

Used to estimate the relationship between magnetic characteristics and pulse duration. Also used to SY-922 estimate electromagnetic parts, transformers for DC-DC power supplies and inductors. (Can be Yes Yes Yes

Pulse generator connected to a user’s drive circuit.) 50 ns to 100 ms.

SY-943 Used to estimate magnetic characteristics by pulse excitation. Control of unnecessary ringing based Yes Yes Yeson unipolarity, bipolarity and built-in filter. (Can be connected to a user’s drive circuit.)

DC combolution characteristic SY-805 Adds DC combolution characteristic measurement function to the B-H analyzer SY-8232. Yesmeasurement addition IE-830* Adds DC combolution characteristic measurement function to the B-H analyzer SY-8217. Yes

DC bias power supply SY-931 Used to estimate DC combolution characteristics. Yes Yes YesCurrent output: 10 A max., 1 mH. Frequency response: 1 MHz max.

200 V input pod SY-925 Applied to exciting voltages up to 200 V. Voltage detection sensitivity: ±200 V. YesCurrent detection sensitivity: ±5 A.

SY-942 Low-frequency, high-magnetic field measurement of thin film materials. Yes1 kHz to 100 kHz, 100 mOe to 10 Oe.

Thin film measurement pod SY-924 Used to measure high-frequency saturation characteristics and permeability of rectangular magnetic Yesthin films. 10 Oe, 100 kHz to 10 MHz with a B-H analyzer SY-8232.

SY-948* Used to measure high-magnetic field of thin film materials including amorphous materials. 5 kHz to Yes500 kHz, 10 Oe with a B-H analyzer SY-8217.

Function addition SY-505 Adds 1 Hz excitation function to the B-H analyzer and extends the measurement frequency from 1 Hz Yes1 Hz excitation to 10 MHz.

Pod SY-938 High-sensitivity pod exclusively for near DC current measurement of magnetic materials. The SY-505 Yesis also required to use this pod.

Low-frequency high-sensitivity pod SY-926 Used to estimate low-frequency magnetic characteristics (Bms, Hcm) of small items. YesVoltage detection sensitivity: ±500 µV to 20 mV.

High-frequency high-sensitivity pod SY-927 Used to measure high-frequency initial permeability. Current detection sensitivity: ±1 mA to 200 mA. Yes

Single plate measurement system SY-937 Used to measure permeability, iron loss, B-H curve, etc. of plate type samples such as silicon steel plates. Sample size: Thickness 0.2 mm to 1.0 mm, width 10 mm to 30 mm, height 60 mm or more. Yes Yes Yes50/60 Hz

Impedance measurement function IE-831 Adds impedance characteristic value computations and characteristic graph display/printing functions Yesaddition to the B-H analyzer. Ls, Rs, tan δ , Z.

Expansion pod SY-928 Pod provided with a BNC input terminal for the detection of current and voltage in a scanner system Yesfor temperature characteristic measurement, user circuit, etc.

Automatic measurement of temperature characteristics of core. Temperature setting –30°C to + Large scanner system for SY-8247 150°C. Max. number of samples 20. Voltage sensitivity ±200 V max. Current sensitivity ±5 A max. Yes Yestemperature characteristic measurement GP-IB interface provided. Volume approx. 100 liters.

IE-1122 Same as the SY-8247, except that the temperature setting is from –10°C to +150°C. Yes Yes

Compact scanner system for Automatic measurement of temperature characteristics of core. Temperature setting –30°C to +130°C

IE-1123 (+150°C – Optional). Max. number of samples 20. Voltage sensitivity ±200 V max. Current sensitivity Yes Yestemperature characteristic measurement ±5 A max. GP-IB interface provided. Volume approx. 40 liters

Wide-temperature scanner system for IE-1124* Temperature setting is available from –80°C to +180°C . Yes Yestemperature characteristic measurement

Turntable SY-918 Auxiliary turntable for use with a scanner system for temperature characteristic measurement. Yes YesMaximum number of samples 20.

Automatic temperature characteristic IE-835 Automatic measurement of the temperature characteristics of samples by controlling the B-H analyzer Yes

measurement softwareSY-8232 and a scanner system for temperature characteristic measurement.

IE-832* Automatic measurement of the temperature characteristics of samples by controlling the B-H analyzer YesSY-8217 and a scanner system for temperature characteristic measurement.

IE-815 Records the results of core loss and B-H curve measurements. The files are in the CSV format and YesMeasurement data recording can be loaded in tabulation software.application software IE-833* Records the results of core loss and B-H curve measurements. The files are in the CSV format and Yes

can be loaded in tabulation software.

Continuous measurement at approx. 2-sec. intervals for incorporation in an automated tester. High-speed measurement function IE-515* Features enhancement of both main unit and controller software (statistical processing, go/no-go Yes

judgment, data logging).

DC - 1 MHz medium amplitude HSA4014IW DC to 1 MHz, 200 VA, ±5.6 A, ±65 V, 0.125 Ω. Manufactured by NF Inc. Yes Yes Yes

DC - 10 MHz medium amplitude 4055 DC to 10 MHz, ±2 A, ±75 V. Approx. 1.5 Ω Manufactured by NF Inc. Yes Yes Yes

10 kHz - 10 MHz medium amplitude 2100L 10 kHz to 10 MHz, 100 VA, 70 Vrms, 50 Ω. Manufactured by ENI Inc. Yes Yes Yes

DC - 3 MHz large amplitude IE-1125 DC to 3 MHz, 400 VA ±5 A, ±150 V, 1 Ω. Manufactured by NF Inc. Yes Yes Yes

1 kHz - 5 MHz large amplitude IE-1119 1 kHz to 5 MHz, 200 VA, ±2 A, ±150 V, 1 Ω. Manufactured by NF Inc. Yes Yes Yes

Trolley for measuring instruments MT-600S Can hold a B-H analyzer and power amplifier. With transport casters. Yes Yes Yes

Thermal paper TF50KS-E2 112 mm wide, 10 rolls/carton. Yes Yes

AC couple SY-504 Eliminates DC components below 10 kHz from the signal applied to the samples. 5 A max. Yes Yes Yes

GP-IB cable 408JE-102 GP-IB interface connection cable. 2 m. Yes Yes Yes

408JE-104 GP-IB interface connection cable. 4 m. Yes Yes Yes

Exci

tatio

n po

wer

ampl

ifier

s

Accessories, Options and Applications For B-H analyzers (SY-8232, SY-8217, SY-8101)B-H analyzers are ideal for evaluation of magnetic materials in many fields.The accessories listed below have been designed to optimize the efficiency and versatility of our B-H analyzers.

• If you use a GP-IB interface, we recommend the one manufactured by NI (National Instruments).• If you want to add any of the above options to your B-H analyzer or ancillary equipment, please contact the sales or engineering staff

at your nearest IWATSU representative.• To select an excitation power amplifier, please contact the sales or engineering staff at your nearest IWATSU representative.

* Under development

p30-p40 00.9.28 2:46 PM ページ 36

Page 38: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

37

The SY-924 measurement pod has been designedfor high-frequency, high-magnetic field measurementof thin film samples (> 100 kHz, 100m Oe to 10 Oe).In the pod, an excitation winding and acompensation coil-system detection winding are builtin.Measurement can be performed easily by insertingrectangular samples, which are vacuum-evaporatedon a glass plate (or a non-magnetic substrate), intothe sample insertion hole on the SY-924.

Thin Film Measurement Pod SY-924 Option for B-H analyzers

<Major applications> Thin film materials for magnetic heads

Measurement of high-frequencysaturation characteristics (Magnetic field > 100m Oe)

Measurement of high-frequencypermeability characteristics (Magnetic field > 100m Oe)

The SY-942 measurement pod has been designedfor low-frequency, high-magnetic field measurementof thin film materials with thickness around 500 Å (> 1 kHz, 100m Oe to 10 Oe). In the pod, anexcitation winding and a compensation coil-systemdetection winding are built in.Measurement can be performed easily by insertingrectangular samples, which are vacuum-evaporatedon a glass plate (or a non-magnetic substrate), intothe sample insertion hole on the SY-942.Low-frequency measurements (1 kHz to 100 kHz)are required to provide high sensitivity in detectionbecause the induced voltage level is about µV atthese frequencies. The S-942 pod features inducted

Thin Film Measurement Pod SY-942 Option for B-H analyzers

voltage detection and excitation current detectionsensitivities about 1,000 times that of the SY-924pod, enabling measurement and estimation of low-permeability materials and very thin film materials (< 1000 Å).<Major applications> Thin film materials for magnetic heads

Measurement of high-frequency saturationcharacteristics (Magnetic field > 100m Oe)

Measurement of high-frequency permeability characteristics (Magnetic field > 100m Oe)

High accuracy is difficult to achieve when measuringlow-frequency magnetic characteristics such assaturation B-H curves of small soft magneticsamples or low-permeability samples because theamount of voltage induced by magnetization is small.The induced voltage detection sensitivity of the SY-926 pod is increased 100 times (compared to thestandard pod) for low-frequency magneticcharacteristic measurement. By combining it with theS-8232 B-H analyzer, it can be used with excitationfrequencies from 10 Hz to 100 Hz.

Low-Frequency High-Sensitivity Pod SY-926 Option for B-H analyzers

<Major applications> Toroidal sample for magnetic heads Sheet toroidal samples

(Permalloy, stainless steel, etc.) Saturation B-H curve measurement Permeability curve measurement

Rod or rectangular board materials (metallic, ferrite, etc.)

Effective permeability measurement

The SY-927 is the optimum choice for measuringand estimating the AC initial permeability andinductance in high frequencies for ferrite cores, dustcores and magnetic head materials.This pod was developed by enhancing the detectionsensitivity of the standard pod (SY-921) in order todeal with measurement in low magnetic fields andlow magnetic flux density. The excitation anddetection windings of the sample to be measured areconnected to four terminals on the pod. In the pod,an excitation current detection circuit for ±1 mA to±200 mA and an induced voltage detection circuit for±50 mV to ±50 V are built in.

High-Frequency High-Sensitivity Pod SY-927 Option for B-H analyzers

<Major applications> Ferrite core materials Dust core materials Magnetic head materials

AC initial permeability and inductance measurements

The SY-928 includes all the functions of the standardpod (SY-921) plus general-purpose 2-channel inputconnectors (BNC).For ordinary measurements, the excitation windingand detection winding of the sample are connectedto the pod’s excitation and detection terminals.External current and voltage detection circuits canbe connected as well (using the 2-channel inputconnectors).

Expansion Pod SY-928 Option for B-H analyzers

<Major applications> Power ferrite materials

Temperature characteristicmeasurement using a constanttemperature oven (adding an impedanceconversion circuit to the constanttemperature chamber).

Large iron core materials Current detection using a current probe.

The SY-931 can be used to measure the DCsuperimposed inductance characteristics of a choketransformer for DC power supply, etc.The choke transformer (core) is provided to eliminatenoise in DC current, but it is necessary to apply a DCcurrent to the sample in order to measure the relatedcharacteristics. Since an ordinary DC constantcurrent power supply cannot be used for thispurpose because the AC impedance is low, the SY-931 incorporates an inductor for AC insulation.

DC Bias Power Supply SY-931 Option for B-H analyzers

<Major applications> For LCR meter: DC superimposed inductance

measurement of choke transformers. For the SY-8232 B-H analyzer:Core loss

characteristic measurement under DCsuperimposition.

Other: Automated measurement system throughGP-IB with a PC.

<Features> Current output 0A–1A (1 mA resolution)/

0A–10A (10 mA resolution),RL: 1 Ω max

Incorporated inductor 1 mH at 1 MHz, 10A Setting Manual setting or GP-IB

Accessories, Options and Applications

p30-p40 00.9.28 2:46 PM ページ 37

Page 39: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

38

The optional SY-505 and SY-938 add a low-frequency magnetic characteristic measurementfunction for 1 Hz. This can be used to measurevarious magnetic characteristic values at lowfrequencies in the manufacturing research of metallicmaterials, etc. with the SY-8232 B-H analyzer.

1 Hz excitation measurement option (SY-505)This option expands the excitation frequency of theS-8232 B-H analyzer to between 1 Hz and 10 MHz,making it capable of measuring near DC magneticcharacteristics of electromagnetic steel sheets, etc.

1 Hz Excitation Measurement Option SY-505High-Sensitivity Low-Frequency Measurement Pod for 1 Hz Measurement SY-938

Option for B-H analyzers

High-sensitivity low-frequency pod for 1 kHzmeasurement (SY-938)This option is a high-sensitivity pod exclusivelydesigned for excitation measurement of 1 Hz near DCcurrent. The 1 Hz excitation measurement option (SY-505) is requisite for this option.

This function is available as a factory option. Pleaseconsult your nearest IWATSU representative fordetails.

The SY-937 is optimized for measuring thepermeability, iron loss and B-H curves of platesamples such as silicon steel sheets. Until now,Epstein frames have been used to measure the platespecimens. However, they have some problemsincluding the need for a large quantity of samples formeasurement and limited sample size.The SY-937 overcomes these problems by providingthe capability to perform measurements using only apiece of sample, allowing a wider range of samplesizes and data compatibility with Epstein frames.

Single Plate Measurement System SY-937 Option for B-H analyzers

<Major applications> Estimation of magnetic characteristic values including the

saturation magnetic characteristics and core lossand the B-H curves of plate samples made of siliconsteel, permalloy, amorphous alloys, etc.

<Features>Capable of estimation equivalent to Epstein methodwith using a single rectangular sample. Results canbe obtained quickly and easily. Measurable sample size: Thickness 0.2 to 1.0 mm,

width 10 to 30 mm, length 60 mm or more. Measurement frequencies: 50 Hz, 60 Hz., Please consult IWATSU if you measure a sample over the sizes and

frequencies listed above., The SY-928 expansion pod is required when using the SY-937 with the

SY-8232.

m Standard permeability measurement functionThe standard permeability measurement functionoffers the following characteristic values andcharacteristic graphs:

Impedance Measurement Function Addition IE-831 Option for B-H analyzers

L-f characteristic graph/|µ|, θ- f characteristic/ µ’, µ”- fcharacteristic/B-H curves/i, V-t waveform/characteristicvalue list (Hm, Bm, Pc, µa, µ’, µ”, L, θ , VA)m Added functionsThe impedance measurement function addition offersthe following additional functions. L, R-f characteristic graph tan σ -f characteristic graph |Z|, θ -f characteristic graph Characteristic value list (Hm, Bm, Pc, µa, µ’, µ’’,

R, L, |Z|, tan σ ,θ , VA).

The SY-943 is a bipolar or unipolar pulsegenerator. As it can set the pulse duration and amplitudesof the positive and negative pulsesindependently, it can be used to measure themagnetic characteristics of magnetic materialsby pulse signals that are the approximate actualwaveforms of a switching power supply or DC-DC converter.

Pulse Generator SY-943 Option for B-H analyzers<Major applications>1. Loss estimation of transformers for switching

power supplies and DC-DC converters.2. Estimation of response characteristics of relays.3. Estimation of response characteristics of solenoid

valves.4. Pulse duration.5. Output levels.<Features>1. The pulse duration and amplitudes of the positive

and negative pulses can be set independently.Setting can be done manually using the frontpanel switches and dials as well as by automaticsetting via the GP-IB interface.

2. Pulse signals can be generated in synch with thetrigger signal output from the B-H analyzer.

This option adds functions of computingcharacteristics representing the impedance andof displaying and printing the characteristicgraphs to the permeability measurementfunction of the SY-8232 B-H analyzer.

Example of L, R-f characteristic graph Example of tan D-f characteristic graph

3. A built-in filter can vary the positive-going time ofpulse signals. This makes it possible to reduce theeffects of ringing when driving the inductance.

4. With very low jitter (below 5 ns, or belowmeasuring limit of general-purpose pulsegenerators), measurement at high resolution isavailable.

Trigger intervalTRIG INPUT

Positive amplitude

OUTPUT 0 V OFFSET

Positive pulse duration

Negative pulse duration

The SY-922 is used to measure the pulse excitationcharacteristics of power transformers for switchingpower supplies and electromagnetic parts(electromagnetic relays, pulse motors, etc.).The SY-922 outputs a pulse signal in synch with theinput pulse (TTL level), at the set pulse duration andamplitude. The output pulse signal is a 10 Vp-p, 1Asignal. It is suitable for driving a bipolar or MOSpower transistor by the ±10 V variable DC offsetfunction.

Pulse Generator SY-922 Option for B-H analyzers

<Main applications & specifications> Transformer for SWPS:The core loss of a

transformer can be estimated by applying thepulse to the power transistors in a SWPS.

Electromagnetic relay:The pulse excitationcharacteristics can be estimated by directlydriving the coil of electromagnetic relay.

Other: Used to the output booster of a pulseoscillator.

Pulse input: TTL signal, 10 Hz to 10 MHz Pulse duration: 100 ns to 100 s Output level: 10 Vp-p max.(Offset: ±10 V), 1A max.

p30-p40 00.9.28 2:46 PM ページ 38

Page 40: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

Frequency range 1 MHz 5 MHz

Temperature range -307C to +1507C -307C to +1507C

Number of samples Max. 20 Max. 20

39

n Core loss measurement in high-frequency power transformers (using an optional external poweramplifier)

The core loss characteristics of ferrite cores used in high-frequency power transformers can be measured easily by usingan external power amplifier (optional). When the continuousmeasurement function is used, frequency characteristics (Pcv - f) of the core loss can be quickly obtained.

By changing the display mode, the hysteresisloss and eddy-current loss can be approximatedusing the least square method, permittingestimation of the differences in composition andconstruction of materials.

Furthermore, the frequencycharacteristics of amplitude permeability(µ - f) can be shown by changing thedisplay mode.

(Example of a MnZn ferrite material)

g g

m SY-8247: For the SY-8232 (~ 10 MHz),For the SY-8217 (~ 5 MHz)

The SY-8247 has been developed as a constant temperature chamber systemfor use in estimation or tests of core loss temperature characteristics of powerferrite cores. It is designed for the core loss measurement at high frequencies(10 kHz to 5 MHz or 10 MHz).

Temperature control Manual or remote setting of temperatures from -30°C to+150°C.

Cooling system Electric cooling pump, rendering CO2 gas unnecessary.Built-in scanner Manual/remote switching by an exclusive scanner

(4 terminals) with max. 20-sample loading capacity.Optimized for core loss measurement

Excitation circuit, excitation current detection circuit andinduced voltage detection circuit for core lossmeasurement are built in.

Large Scanner Systems for Temperature Characteristic MeasurementSY-8247

Applications

This is a fully automatic measurement system fortemperature characteristics of core loss of switchingpower supply transformer materials.The SY-8628 is ideal for labor saving inmanufacturing inspection processes while the SY-8638 is best for the development of high-frequency and low-loss materials.

Automatic Temperature Characteristic Measurement System SY-8628/SY-8638

Applications

<Measurement example>Measurement example of core loss-temperaturecharacteristic of a low-loss MnZn ferrite materialusing the SY-8628/SY-8638

SY-8628 SY-8638

OthersIE-1123 (Compact Scanner for TemperatureCharacteristic Measurement)

SY-918 (Turntable)

Scanner system

Control circuit

Scanner (Interface)

Heat exchanger

GP-IB

B-H analyzer SY-8217

Power amplifier

Printer For graph &

data output

Construction of SY-8628

Construction of SY-8638

GP-IBScanner system

Control circuit

Scanner (Interface)

Heat exchanger

B-H analyzer SY-8232

Power amplifier

Printer For graph &

data output

IBM PC/AT compatible

PC Windows

SY-928

Accessories, Options and Applications

Major applications of the SY-8232

<= <=

p30-p40 00.9.28 2:47 PM ページ 39

Page 41: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

40

n B-H curve measurementn Measuring the high-frequency

amorphous coreSmall-amplitude to supersaturating B-H curves can bemeasured and the results can be overlapped by using anexternal power amplifier (optional). This is suitable for theanalytical measurement of magnetic cores foroversaturating reactors.

By changing the display mode, a permeability curve (µ -Hm) or magnetization curve (Bm - Hm) can be obtained.This ensures much more stable results with high-frequencymaterials than can be obtained with conventional DCmagnetization measurement.

n Measuring the low-frequency B-Hcurve by substituting the DC-BHcurve tracer

The SY-8232 is optionally capable of measuring 1 Hz, so itcan be used to estimate static characteristics (instead ofusing the more complicated DC-BH curve tracer). Withordinary size samples, it can effectively be used for thestable measurement of Bms and Hc.

n Permeability measurementIn general, tan s is used as the loss factor for magneticmaterials used in inductors. With the SY-8232, complexmagnetic permeability (µ’, µ’’ ) can be measured toestimate loss.

In addition, the SY-8232 can measure permeabilitywith either the primary coil or secondary coil method.This makes it possible to estimate the winding loss(copper loss) separately.

n Thin film material measurementThin film materials can be measured with the B-H curvemeasurement and permeability measurement. The thin filmmeasurement pod (optional) is required for thesemeasurements.

n Measurement of magnetic headmaterials

Magnetic heads are measured in the toroidal shape beforemachining and in the head assembly stage after machining.As the SY-8232 can perform excitation at max. 10 MHz andmin. 10 Hz (optionally 1 Hz), the unit can estimatecharcateristics ranging from static to high-frequency on itsown.

n Measuring material in the form ofmagnetic head assembly

Measuring material in the form of magnetic head assembly

n Measurement of magnetizationdynamic characteristics ofelectromagnetic parts

Electromagnetic parts such as relays, solenoids and valvescan be estimated using the optional pulse excitationmeasurement function.

n Measuring a single-crystal ferritematerial in toroidal shape

(Example of an amorphous core)

(Example with MnZn sintered ferrite)

(Example of MnZn ferrite)

(Example of processing by PC)

Example ofmeasurement ofbcc-Fe-Hf-C thin film(40 mm x 3 mm)

Low-Hc materials can beestimated with excellentreproducibility because themeasurement results areobtained in quantitative figures.

(Example of measurement of the magnetization-frequencycharacteristic of relay)

n Inspection of high-frequency powertransformer core

More accurate inspection must be performed onthe core of a SWPS transformer, in order todecrease core loss. The B-H analyzers havebeen specifically developed as optimummeasurement tools for manufacturing andinspection. They can perform stable core lossmeasurement quickly and simply.

n Saturation B-H curvemeasurement of MnZnpower ferrite cores

The results of measurement at 50 Hz present agood correlation with the DC-BH curve tracermeasurement, and offer highly stable results. Itcan be applied to the inspection of the Hc value.

n Measurement of metallic materials using pulseexcitation

When metallic materials used in step motors and actuators are measured byapplying pulse excitation, magnetic characteristics close to what would bedisplayed in actual operation can be identified.

(Example of measurement of low-loss MnZn ferrite)

Note) Both the DC curve tracer and B-Hanalyzer excite Bms at 1000 A/m and Hcat 100 A/m.

B-H curve and current-voltagewaveform with excitation at arepeating frequency of 100 Hz,pulse duration of 2 ms and appliedvoltage of 2.2 V.

B-H curve and current-voltagewaveform with excitation at arepeating frequency of 100 Hz,pulse duration of 1 ms and appliedvoltage of 2.2 V.

(using the low-frequency measurement pod)

(Printer output example)

(Differences in magnetization depending on pulse duration)

No.

STD1

STD2

Bms(mT)Br(mT)Hc(A/m)Bms(mT)Br(mT)Hc(A/m)

510124

13.7550012515.0

519.9128.7713.437507.66123.6414.5

MeasuringItem

DC CurveTracer

B-HAnalyzer

ff

Other Applications

p30-p40 00.9.28 2:47 PM ページ 40

Page 42: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

Ω

41

Features

Accuracy Range Accuracy Range Frequency RMS Accuracy Range

VOAC7513 ±0.0035%

40 mVto

1000 V1 µV ±0.2%

400 mVto

750 V

15 Hzto

300 kHzTRUE 0.1 mΩ ±0.005%

40 Ωto

400 MΩ

VOAC7512 0.1 µV ±0.0035%

40 mVto

1000 V1 µV ±0.2%

400 mVto

750 V

15 Hzto

100 kHzTRUE 0.1 mΩ ±0.005%

40 Ωto

400 MΩ

VOAC7510 1 µV ±0.0035%

400 mVto

1000 V1 µV ±0.2%

400 mVto

750 V

15 Hzto

100 kHzTRUE 0.1 mΩ ±0.005%

40 Ωto

400 MΩ

VOAC7413 1 µV ±0.04%

40 mVto

1000 V10 µV ±0.2%

400 mVto

750 V

15 Hzto

100 kHzTRUE 1 mΩ ±0.06%

40 Ωto

400 MΩ

VOAC7412 1 µV ±0.04%

40 mVto

1000 V10 µV ±0.2%

400 mVto

750 V

20 Hzto

100 kHzAVE 1 mΩ ±0.06%

40 Ωto

400 MΩ

VOAC7411

High speedauto ranging

Max. samplerate: 20 times/s

REL/AVG math True RMS

1 µV ±0.07%40 mV

to1000 V

10 µV ±0.25%400 mV

to750 V

20 Hzto

100 kHzTRUE 1 mΩ ±0.08%

40 Ωto

400 MΩ

DCV ACV

Max. reso

lution

Temperaturemeasurement:-200°C to+1600°C

Max. samplerate: 100times/s

4-wire ohmsmeasurement

3000 datamemories

Max. samplerate:100 times/s

4-wire ohmsmeasurement

3000 datamemories

5-1/2

409999

5-1/2

409999

4-1/2

40999

Frequencymeasurement:Up to 200 kHz

Temperaturemeasurement

Max. samplerate: 100times/s

REL/AVG/P-Pmath

Average RMS

0.1 µV

Powermeasurement:

Temperaturemeasurement

Max. samplerate: 100times/s

1000 datamemories

MAX/MINfunction

Numberof digits

Full-scale

Frequencymeasurement:10 Hz to 400kHz

Max. samplerate: 100times/s

4-wire ohmsmeasurement

3000 datamemories

Max. reso-lution

Max.reso-lution

DIGITAL MULTIMETER SELECTION GUIDE

5-1/2

409999

4-1/2

40999

4-1/2

40999

p41-p58 00.9.28 3:10 PM ページ 41

Page 43: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

REL%

AVGMAX/MIN

STORE

REL%

AVGMAX/MIN

STORE

REL%

AVGMAX/MIN

STORE

RELAVGMAX/MIN

STORE

SC-302A PrinterunitSC-303A GPIBunitSC-304A BCDout unitSC-305A D/AunitSC-306 Batteryunit

LED

42

4-wire

Max.reso-lution

Range Range Range

Yes 10 nA4 mA

to4 A

N/A10 Hz

to400 kHz

Yes 10 nA4 mA

to4 A

–200°Cto

+1600°CN/A N/A

N/A 10 nA400 µA

to10 A

–50°Cto

+1370°C

Up to1,250 W at 100 V.

Up to2,500 Wat 200 V

N/A

N/A 10 nA400 µA

to10 A

–50°Cto

+1370°CN/A

10 Hzto

200 kHz

10 nA400 µA

to10 A

–20°Cto

+120°Cusing

optionalTD-70

N/A

ACA

N/A

10 nA

10 nA

10 nA

10 nA

10 nA

Ω

Max.reso-lution

Range

4 mAto

4 A

4 mAto

4 A

400 µAto

10 A

400 µAto

10 A

400 µAto

10 A

DCA Temperature

–200°Cto

+1600°C

PowerFre-

quency

N/A

Con-tinuity

test

Autorange

Yes 100 Yes

191 Wx 80 Hx 260 L

1.9 kg

Yes 100 Yes

191 Wx 80 Hx 260 L

1.9 kg

Yes 100 Yes

191 Wx 80 Hx 260 L

1.8 kg

Yes 100 Yes

191 Wx 80 Hx 260 L

1.8 kg

Yes 20 Yes

191 Wx 80 Hx 260 L

1.8 kg

Math

RELAVGp-p

RELAVG

Dis-play

LED

LED

LED

LED

Samplerate

(times/s)(at DCVmode)

Size(mm)

WeightOptions

Yes 10 nA4 mA

to4 A

–20°Cto

+120°Cusing

optionalTD-70

N/A N/A10 nA4 mA

to4 A

Yes 100 Yes

191 Wx 80 Hx 260 L

1.9 kg

LED

p41-p58 00.9.28 3:10 PM ページ 42

Page 44: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

Sample rate mode Reading rateSLOW ≈4 times/secMID ≈20 times/secFAST ≈100 times/sec

Resolution Voltage dropRange

23±5°C, 23±5°C,Slow,Mid Fast across input90days one year

5-1/2 4-1/2 terminal4 mA 10 nA 100 nA40 mA 0.05 + 5 0.08 + 7 100 nA 1 µA 600 mV400 mA 1 µA 10 µA

4000 mA2 A 0.05 + 5 0.08 + 7

10 µA 100 µA 1 V>2 A 0.1 + 5 0.13 + 7

40 Ω to 400 kΩ 50 ms4000 kΩ 0.1s Zero to full scale within the same40 MΩ 0.5s range400 MΩ 5s

Sample rate mode Reading rateSLOW ≈4 times/sec

MID ≈20 times/secFAST 40 Ω to 4000 kΩ ≈100 times/sec

40 MΩ, 400 MΩ ≈20 times/sec

ResolutionRange

23±1°C, 23±5°C, 23±5°C,Slow,Mid Fast Test current24hrs 90days one year

5-1/2 4-1/2 40 Ω 0.01 + 10 0.02 + 10 0.025 + 10 0.1 mΩ 1 mΩ ≈10 mA400 Ω 1 mΩ 10 mΩ ≈10 mA4k Ω 0.005 + 3 0.01 + 3 0.014 + 3 10 mΩ 100m Ω ≈1 mA40 kΩ 100 mΩ 1 Ω ≈100 µA400 kΩ 0.006 + 3 0.011 + 3 0.015 + 3 1 Ω 10 Ω ≈10 µA4000 kΩ 0.012 + 10 0.03 + 10 0.033 + 10 10 Ω 100 Ω ≈1 µA40 MΩ 0.05 + 20 0.2 + 20 0.25 + 20 100 Ω 1 kΩ ≈100 nA400 MΩ 0.5 + 50 1.5 + 50 1.5 + 50 1 kΩ 10 kΩ ≈10 nA

Frequency Crest factor1–1.5 1.5–2 2–3

15 Hz~20 kHz 0.05% 0.15% 0.3%20 kHz~300 kHz 0.2% — —

Range Resolution Frequency23±5°C, 23±5°C, Input90days one year resistance

400 mV 1 µV 15 Hz–45 Hz 0.5 + 100 0.5 + 1504 V 10 µV 45 Hz–100 Hz 0.25 + 100 0.25 + 150 ≈2 MΩ/40 V 100 µV 100 Hz–50 kHz 0.2 + 100 0.2 + 150 100 pF or400 V 1 mV 50 kHz–100 kHz 0.5 + 300 0.5 + 300 below750 V 10 mV 100 kHz–300 kHz 2.5 + 1000 2.5 + 1000

Sample rate mode Reading rate NMR CMRSLOW ≈4 times/sec

>55 dB 110 dBMID ≈20 times/secFAST ≈100 times/sec 0 dB 55 dB

ResolutionRange

23±1°C,s 23±5°C, 23±5°C,Slow,Mid Fast

Input24hr 90days one year

5-1/2 4-1/2resistance

40 mV 0.008 + 10 0.015 + 10 0.025 + 10 0.1 µV — 100 MΩ400 mV 0.0035 + 5 0.008 + 5 0.012 + 5 1 µV 10 µV

1000 MΩ4 V 0.0035 + 2 0.008 + 2 0.012 + 2 10 µV 100 µV40 V 0.004 + 5 0.012 + 5 0.016 + 5 100 µV 1 mV400 V 0.004 + 2 0.012 + 2 0.016 + 2 1 mV 10 mV ≈10 MΩ1000 V 10 mV 100 mV

43

VOAC 7513

5-1/2 digits, full-scale 409999 Max. sample rate 100 times/sec. (at 4-1/2 digits

mode) High resolution

DCV: 0.1 µV, ACV: 1 µV, Ω: 0.1 mΩDCA/ACA: 10 nA, °C: 0.1°C, Hz: 0.1 mHz

TRUE RMS ACV/ACA (DC+AC)V/(DC+AC)A Temperature measurement from –200°C to

1600°C Frequency measurement of 10 Hz to 400 kHz 4-wire ohms measurement Storage of 3,000 data A variety of optional units enhance measuring

efficiency.

Specifications

1. DC VOLTSAccuracy

Sample rate : SLOW/MID : ± (% of reading + digits)

* The accuracy at 23±1°C, and 24 hrs. is relative to the calibration standards.* The accuracy at 400 mV range is specified after zero compensation through the REL

operation.* Add 0.003% of reading when used with SC-306 battery unit. * In FAST sample mode, add 5 digits to the accuracy in SLOW and MID sample modes.Temperature coefficient (0°C to 18°C, 28°C to 50°C)

(1/10 of the accuracy for each range)/°CMaximum input voltage 40 mV to 4 V range : ±1100 V DC (5sec.)

±500 V DC (continuous)40 V to 1000 V range : ±1100 V DC (continuous)

Sample rate and noise rejection

* Reading rates are specified with math function OFF.* NMR : 50/60 Hz : ±0.1%* CMR :1 kΩ unbalance, DC, 50/60 Hz : ±0.1%

2. AC VOLTSAccuracy (For sine wave only) : ±(% of reading + digits)

400 mV to 400 V range : Accuracy is specified for 20,000 counts or more.750 V range : Accuracy is specified for 10,000 counts or more.

* In the 400V range, accuracy is specified at 100 kHz or lower.* In the 750V range, accuracy is specified at 20 kHz or lower.* In SLOW sample mode, accuracy is specified at 15 Hz or higher. * In FAST sample mode, accuracy is specified at 200 Hz or higher.Temperature coefficient (0°C to 18°C, 28°C to 50°C)

(1/10 of the accuracy for each range)/°CMaximum input voltage All range : 780 Vrms (continuous), 1100 V peakAC converter True RMS.

Signals other than sine wave : add the following values to the accuracy of the sine wave.

* Response time is the time for meter reading to reach within 100 counts of final value in thesame range.

Sample rate

3. RESISTANCE Ω (2WΩ/4WΩ)Accuracy Sample rate : SLOW/MID : ± (% of reading + digits)

* The accuracy at 23±1°C, and 24 hrs. is relative to the calibration standards.* The accuracy at 40 Ω to 4 kΩ ranges are specified after zero compensation through the

REL operation.* Add 0.003% of reading when used with SC-306 battery unit.* In FAST sample mode, add the following values to the accuracy in SLOW and MID sample

modes. 40 Ω to 4 kΩ ranges . . . . . . . 5 digits40 kΩ to 4000 kΩ ranges . . . . . 30 digits40 MΩ to 400 MΩ ranges . . . . . 10 digits

Temperature coefficient (0°C to 18°C, 28°C to 50°C)(1/10 of the accuracy for each range)/°C

Maximum input voltage ±500 V DC Between V/Ω and COM terminals, and between 4 WΩSENSE H and L terminals

Open circuit test voltage 6.8 V or less

Sample rate Sample rate and noise rejection

Response time

4. DC CURRENTAccuracy Sample rate : SLOW/MID : ± (% of reading + digits)

* In FAST sample mode, add 10 digits to the accuracy in SLOW and MID sample modes. Temperature coefficient (0°C to 18°C, 28°C to 50°C)

(1/10 of the accuracy for each range)/°C Maximum current Protected by a 4 A fuse.

4mA to 400 mA range : 4 A DC or rms (5 sec.) 1.5 A DC or rms (continuous)

4000 mA range : 4 A DC or rms (continuous)Sample rate

Sample rate mode Reading rate Frequency Response timeSLOW ≈4 times/sec 15 Hz–300 kHz 2secFAST ≈20 times/sec 200 Hz–300 kHz 1sec

>=

>=

>=

>=

>=>=

<=

<=<=

p41-p58 00.9.28 3:10 PM ページ 43

Page 45: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

Sample rate mode Reading rateSLOW ≈4 times/secFAST ≈8.3 times/sec

Sample rate mode Reading rateSLOW ≈4 times/secFAST ≈20 times/sec

Sample rate mode Reading rate Gated timeSLOW ≈1 times/sec ≈1 sec

MID ≈4 times/sec ≈200 msecFAST ≈20 times/sec ≈20 msec

Thermocouple type Temperature range Resolution AccuracyR 0°C – +1600°C 0.2 + 30K (CA) –200°C – +1370°C 0.1 + 15T (CC) –200°C – +380°C 0.1°C 0.15 + 15J (IC) –200°C –+900°C 0.15 + 15E (CRC) –200°C – +1000°C 0.15 + 15

Maximum reading Resolution(Hz)Range Slow Mid Fast Slow Mid Fast

5-1/2 4-1/2 3-1/240 Hz 40.9999 40.999 — 0.1–0.8 m 1–4 m —400 Hz 409.999 409.99 409.9 1–8 m 10–40 m 0.1–0.44 kHz 4.09999 4.0999 4.099 10–80 m 0.1–0.4 1–440 kHz 40.9999 40.999 40.99 0.1–0.8 1–4 10–40400 kHz 209.999 409.99 409.9 1–8 10–40 100–400

Frequency Crest factor1–1.5 1.5–2 2–3

15 Hz~1 kHz 0.05% 0.15% 0.3%

44

5. AC CURRENTAccuracy 23±5°C, one year

Accuracy is specified for 20,000 counts or more: ± (% of reading + digits)

* Accuracy is specified at 15 Hz or higher in SLOW and 200 Hz or higher in FAST samplemode.

* DC component must be smaller than five times of the range.Temperature coefficient (0°C to 18°C, 28°C to 50°C)

(1/10 of the accuracy for each range)/°CAC converter True RMS.Maximum current Protected by a 4 A fuse.

4 mA to 400 mA range : 4 A DC or rms (5 sec.) 1.5 A DC or rms (continuous)

4000 mA range : 4 A DC or rms (continuous)Signals other than sine wave : Add the following values to the accuracy of the sine wave

Sample rate

6. TemperatureAccuracy 23±5°C, one year : ±(% of reading + digits)

* Not includes the accuracy of thermocouple.Temperature coefficient (0°C to 18°C, 28°C to 50°C)

±0.1°C/°C (for any thermocouples)Interporation Linear interpolation

Sample rate

7. FREQUENCY (Hz)Accuracy Sample rate : 23±5°C one year : ±0.5 (% of reading + digits)

Temperature coefficient (0°C to 18°C, 28°C to 50°C)(±0.005% of reading)/°C

Measuring method Reciprocal methodInput range ACV 400 mV to 400V range

10 Hz to 100 kHz : 5% to five times of the range100 kHz to 400 kHz : 30% to three times of the range

Maximum input voltage Up to 200 kHz for input of 200 V to 400 V rms and up to100 kHz for an input of 400 V rms or more.

Sample rate and gated time

Range Resolution Frequency Accuracy Voltage drop across(Sine wave only) input terminal

4 mA 10 nA40 mA 100 nA 15 Hz–45 Hz 1.0 + 200 600 mVrms400 mA 1 µA 45 Hz–1 kHz 0.4 + 2004000 mA 1 µA 1 Vrms

8. MATH and MISCELLANEOUS FUNCTIONS8–1. REL and % MATH1 REL math

Y=X-A Y : Reading value X : Measurement value. A : Reference value.

2 % math Y = X/A x 100 Y : Reading value.

X : Measurement value. A : Reference value.

* The function shall be same for all values. * Full scale is + 999999 under no over-range condition. * Math ON/OFF and reference value are stored in each function. * The % indicator lights at % math function.

8-2. MAX/MIN math Maximum and minimum values are stored in the internal memory in the samefunction and the same range. * Data are read out in the RECALL mode.

8-3. AVG math Moving average of 0 to 100 times (from the keys) or 0 to 255 times (via GP-IB) is available. Setting the number of average to 0 disables AVG math function with AVGindicator off * When used in TRIG or remote mode, the AVG math is run once up to thespecified number of average.

8-4. STORE function The internal memory stores up to 3,000 data with the address from 0 to 2999. * Data are read out in the RECALL mode.

8-5. Continuity test Continuity test is available by pushing the Ω•) ) ) key at the 2WΩ function. Threshold level : 17,000 counts ±10,000 counts Accuracy : Two times of the resistance measurement accuracy. Sample rate : Approx. 20 times/sec. * The resistance measurement is available in continuity test.

8-6. A/D converter Converting method: Triple slope integration. Integration time

SLOW/MID : 20 m sec (200 m sec) at 50 Hz power line frequency16.67 m sec (200 m sec) at 60 Hz Power line frequency The number in the parentheses is at DCV 40 mV range forVOAC 7512 and VOAC 7513.

FAST : 2msec at 50 Hz and 60 Hz power line frequencies. Samespecification as SLOW/ MID mode at ACV/ ACA function and 40 MΩ or higher range in 2 WΩ/4 WΩ function.

* Integration time is automatically adjusted depends on the power linefrequency, when used with AC power source.

* Manual set of integration time is available, when used with DC powersource

8-7. Battery back-up The last setup before the power off including STORE data is recalled atturning power on when SET UP function is ON..

9. GENERALDisplay : 7-segment LED of 11mm height. Full scale : 409999 (A/D converter full scale)

999999 (REL math full scale) Over range display : UUUUUUConverting method : Drift compensated triple slope integration. Polarity indication : “—” indication at negative polarity. Range selection : AUTO/MANUAL or remote control by using option

unit. AUTO ranging : Range up when more than 409999 counts.

Range down when less than 036000 counts. Function selection : MANUAL or remote control by using option unit.Withstand voltage : ±500 V DC (between COM input and ground

terminals) Power supply : AC100V ±10% 50/60 Hz or battery operation by

using SC-306 option unit. Option : AC117V, 217V, or 234VPower consumption : Less than 8W without option unit Operating temperature : 0°C to 50°COperating humidity : Less than 80% RH (0°C to 40°C)

Less than 60% RH (40°C to 50°C) Warm up time : 1hour after turning power on. Dimensions : Approx. 191 (W) x 80 (H) x 260 (L) mm Weight : Approx. 1.9 kg Accessories : Power code (1), Test lead (1 set). Fuses (4),

Alignment screw driver (1), Accessory bag (1),Instruction manual (1)

<=

<=

p41-p58 00.9.28 3:10 PM ページ 44

Page 46: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

Sample rate mode Reading rateSLOW ≈4 times/secMID ≈20 times/secFAST ≈100 times/sec

45

Specifications

5-1/2 digits, full-scale 409999 Max. sample rate 100 times/sec. (at 4-1/2 digits

mode) High resolution

DCV: 1 µV, ACV: 1 µ V, Ω: 0.1 mΩ, DCA/ACA : 10 nA, °C: 0.1°C

TRUE RMS ACV/ACA Temperature measurement from –200°C to

1600°C 4-wire ohms measurement Storage of 3,000 data A variety of optional units enhance measuring

efficiency.

ResolutionRange

23±1°C,s 23±5°C, 23±5°C,Slow,Mid Fast

Input24hr 90days one year

5-1/2 4-1/2resistance

40 mV 0.008 + 10 0.015 + 10 0.025 + 10 0.1 µV — 100 MΩ400 mV 0.0035 + 5 0.008 + 5 0.012 + 5 1 µV 10 µV

1000 MΩ4 V 0.0035 + 2 0.008 + 2 0.012 + 2 10 µV 100 µV40 V 0.004 + 5 0.012 + 5 0.016 + 5 100 µV 1 mV400 V 0.004 + 2 0.012 + 2 0.016 + 2 1 mV 10 mV ≈10 MΩ1000 V 10 mV 100 mV

Sample rate mode Reading rate NMR CMRSLOW ≈4 times/sec

>55 dB 110 dBMID ≈20 times/secFAST ≈100 times/sec 0 dB 55 dB

Range Resolution Frequency23±5°C, 23±5°C, Input90days one year resistance

400 mV 1 µV 15 Hz–45 Hz 0.5 + 100 0.5 + 1504 V 10 µV 45 Hz–100 Hz 0.25 + 100 0.25 + 150 ≈2 MΩ/40 V 100 µV 100 Hz–50 kHz 0.2 + 100 0.2 + 150 100 pF or400 V 1 mV 50 kHz–100 kHz 0.5 + 300 0.5 + 300 below750 V 10 mV

Frequency Crest factor1–1.5 1.5–2 2–3

15 Hz~20 kHz 0.05% 0.15% 0.3%20 kHz~300 kHz 0.2% — —

Sample rate mode Reading rate Frequency Response timeSLOW ≈4 times/sec 15 Hz–100 kHz 2 secFAST ≈20 times/sec 200 Hz–100 kHz 1 sec

* Response time is the time for meter reading to reach within 100 counts of final value in thesame range.

Sample rate

1. DC VOLTSAccuracy

Sample rate : SLOW/MID : ± (% of reading + digits)

* The accuracy at 23±1°C, and 24 hrs. is relative to the calibration standards.* The accuracy at 400 mV range is specified after zero compensation through the REL

operation.* Add 0.003% of reading when used with SC-306 battery unit. * In FAST sample mode, add 5 digits to the accuracy in SLOW and MID sample modes.Temperature coefficient (0°C to 18°C, 28°C to 50°C)

(1/10 of the accuracy for each range)/°CMaximum input voltage 40 mV to 4 V range : ±1100 V DC (5sec.)

±500 V DC (continuous)40 V to 1000 V range : ±1100 V DC (continuous)

Sample rate and noise rejection

* Reading rates are specified with math function OFF.* NMR : 50/60 Hz : ±0.1%* CMR :1 kΩ unbalance, DC, 50/60 Hz : ±0.1%

2. AC VOLTSAccuracy (For sine wave only) : ±(% of reading + digits)

400 mV to 400 V range : Accuracy is specified for 20,000 counts or more.750 V range : Accuracy is specified for 10,000 counts or more.

* In the 750 V range, accuracy is specified at 20 kHz or lower.* In SLOW sample mode, accuracy is specified at 15 Hz or higher. * In FAST sample mode, accuracy is specified at 200 Hz or higher.Temperature coefficient (0°C to 18°C, 28°C to 50°C)

(1/10 of the accuracy for each range)/°CMaximum input voltage All range : 780 Vrms (continuous), 1100 V peakAC converter True RMS.

Signals other than sine wave : add the following values to the accuracy of the sine wave.

Resolution Voltage dropRange

23±5°C, 23±5°C,Slow,Mid Fast across input90days one year

5-1/2 4-1/2 terminal4 mA 10 nA 100 nA40 mA 0.05 + 5 0.08 + 7 100 nA 1 µA 600 mV400 mA 1 µA 10 µA

4000 mA2 A 0.05 + 5 0.08 + 7

10 µA 100 µA 1 V>2 A 0.1 + 5 0.13 + 7

40 Ω to 400 kΩ 50 ms4000 kΩ 0.1s Zero to full scale within the same40 MΩ 0.5s range400 MΩ 5s

Sample rate mode Reading rateSLOW ≈4 times/sec

MID ≈20 times/secFAST 40 Ω to 4000 kΩ ≈100 times/sec

40 MΩ, 400 MΩ ≈20 times/sec

ResolutionRange

23±1°C, 23±5°C, 23±5°C,Slow,Mid Fast Test current24hrs 90days one year

5-1/2 4-1/2 40 Ω 0.01 + 10 0.02 + 10 0.025 + 10 0.1 mΩ 1 mΩ ≈10 mA400 Ω 1m Ω 10 mΩ ≈10 mA4 kΩ 0.005 + 3 0.01 + 3 0.014 + 3 10 mΩ 100 mΩ ≈1 mA40 kΩ 100 mΩ 1 Ω ≈100 µA400 kΩ 0.006 + 3 0.011 + 3 0.015 + 3 1 Ω 10 Ω ≈10 µA4000 kΩ 0.012 + 10 0.03 + 10 0.033 + 10 10 Ω 100 Ω ≈1 µA40 MΩ 0.05 + 20 0.2 + 20 0.25 + 20 100 Ω 1 kΩ ≈100 nA400 MΩ 0.5 + 50 1.5 + 50 1.5 + 50 1 kΩ 10 kΩ ≈10 nA

3. RESISTANCE Ω (2WΩ/4WΩ)Accuracy Sample rate : SLOW/MID : ± (% of reading + digits)

* The accuracy at 23±1°C, and 24 hrs. is relative to the calibration standards.* The accuracy at 40 Ω to 4 kΩ ranges are specified after zero compensation through the

REL operation.* Add 0.003% of reading when used with SC-306 battery unit.* In FAST sample mode, add the following values to the accuracy in SLOW and MID sample

modes. 40 Ω to 4 kΩ ranges . . . . . . . 5 digits40 kΩ to 4000 kΩ ranges . . . . . 30 digits40 MΩ to 400 MΩ ranges . . . . . 10 digits

Temperature coefficient (0°C to 18°C, 28°C to 50°C)(1/10 of the accuracy for each range)/°C

Maximum input voltage ±500 V DC Between V/Ω and COM terminals, and between 4 WΩSENSE H and L terminals

Open circuit test voltage 6.8 V or less

Sample rate Sample rate and noise rejection

Response time

4. DC CURRENTAccuracy Sample rate : SLOW/MID : ± (% of reading + digits)

* In FAST sample mode, add 10 digits to the accuracy in SLOW and MID sample modes. Temperature coefficient (0°C to 18°C, 28°C to 50°C)

(1/10 of the accuracy for each range)/°C Maximum current Protected by a 4 A fuse.

4 mA to 400 mA range : 4 A DC or rms (5 sec.) 1.5 A DC or rms (continuous)

4000 mA range : 4 A DC or rms (continuous)Sample rate

>=

<=<=

<=

>=

>=

>=

<=

VOAC 7512

<=

p41-p58 00.9.28 3:10 PM ページ 45

Page 47: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

Sample rate mode Reading rateSLOW ≈4 times/secFAST ≈20 times/sec

Sample rate mode Reading rateSLOW ≈4 times/secFAST ≈8.3 times/sec

46

Thermocouple type Temperature range Resolution AccuracyR 0°C – +1600°C 0.2 + 30K (CA) –200°C – +1370°C 0.1 + 15T (CC) –200°C – +380°C 0.1°C 0.15 + 15J (IC) –200°C – +900°C 0.15 + 15E (CRC) –200°C – +1000°C 0.15 + 15

5. AC CURRENTAccuracy 23±5°C, one year

Accuracy is specified for 20,000 counts or more: ± (% of reading + digits)

* Accuracy is specified at 15 Hz or higher in SLOW and 200 Hz or higher in FAST samplemode.

* DC component must be smaller than five times of the range.Temperature coefficient (0°C to 18°C, 28°C to 50°C)

(1/10 of the accuracy for each range)/°CAC converter True RMS.Maximum current Protected by a 4 A fuse.

4 mA to 400 mA range : 4 A DC or rms (5 sec.) 1.5 A DC or rms (continuous)

4000 mA range : 4 A DC or rms (continuous)Signals other than sine wave : Add the following values to the accuracy of the sine wave

Sample rate

6. TemperatureAccuracy 23±5°C, one year : ±(% of reading + digits)

* Not includes the accuracy of thermocouple.Temperature coefficient (0°C to 18°C, 28°C to 50°C)

±0.1°C/°C (for any thermocouples)Interporation Linear interpolation

Sample rate

Range Resolution Frequency Accuracy Voltage drop across(Sine wave only) input terminal

4 mA 10 nA40 mA 100 nA 15 Hz–45 Hz 1.0 + 200 600 mVrms400 mA 1 µA 45 Hz–1k Hz 0.4 + 2004000 mA 1 µA 1 Vrms

7. MATH and MISCELLANEOUS FUNCTIONS

7–1. REL and % MATH1 REL math

Y=X-A Y : Reading value X : Measurement value. A : Reference value.

2 % math Y = X/A x 100 Y : Reading value.

X : Measurement value. A : Reference value.

* The function shall be same for all values. * Full scale is + 999999 under no over-range condition. * Math ON/OFF and reference value are stored in each function. * The % indicator lights at % math function.

7-2. MAX/MIN math Maximum and minimum values are stored in the internal memory in the samefunction and the same range. * Data are read out in the RECALL mode.

7-3. AVG math Moving average of 0 to 100 times (from the keys) or 0 to 255 times (via GP-IB) is available. Setting the number of average to 0 disables AVG math function with AVGindicator off * When used in TRIG or remote mode, the AVG math is run once up to thespecified number of average.

7-4. STORE function The internal memory stores up to 3,000 data with the address from 0 to 2999. * Data are read out in the RECALL mode.

7-5. Continuity test Continuity test is available by pushing the Ω•) ) ) key at the 2 WΩ function. Threshold level : 17,000 counts ±10,000 counts Accuracy : Two times of the resistance measurement accuracy. Sample rate : Approx. 20 times/sec. * The resistance measurement is available in continuity test.

7-6. A/D converter Converting method: Triple slope integration. Integration time

SLOW/MID : 20 m sec (200 m sec) at 50 Hz power line frequency16.67 m sec (200 m sec) at 60 Hz Power line frequency The number in the parentheses is at DCV 40 mV range forVOAC 7512 and VOAC 7513.

FAST : 2msec at 50Hz and 60Hz power line frequencies. Samespecification as SLOW/ MID mode at ACV/ ACA function and 40 MΩ or higher range in 2 WΩ/ 4 WΩ function.

* Integration time is automatically adjusted depends on the power linefrequency, when used with AC power source.

* Manual set of integration time is available, when used with DC powersource

7-7. Battery back-up The last setup before the power off including STORE data is recalled atturning power on when SET UP function is ON..

8. GENERALDisplay : 7-segment LED of 11mm height. Full scale : 409999 (A/D converter full scale)

999999 (REL math full scale) Over range display : UUUUUUConverting method : Drift compensated triple slope integration. Polarity indication : “—” indication at negative polarity. Range selection : AUTO/MANUAL or remote control by using option

unit. AUTO ranging : Range up when more than 409999 counts.

Range down when less than 036000 counts. Function selection : MANUAL or remote control by using option unit.Withstand voltage : ±500 V DC (between COM input and ground

terminals) Power supply : AC100V ±10% 50/60 Hz or battery operation by

using SC-306 option unit. Option : AC117V, 217V, or 234VPower consumption : Less than 8W without option unit Operating temperature : 0°C to 50°COperating humidity : Less than 80% RH (0°C to 40°C)

Less than 60% RH (40°C to 50°C) Warm up time : 1hour after turning power on. Dimensions : Approx. 191 (W) x 80 (H) x 260 (L) mm Weight : Approx. 1.9 kg Accessories : Power code (1), Test lead (1 set). Fuses (4),

Alignment screw driver (1), Accessory bag (1),Instruction manual (1)

Frequency Crest factor1–1.5 1.5–2 2–3

15 Hz~1 kHz 0.05% 0.15% 0.3%

<=

<=

p41-p58 00.9.28 3:10 PM ページ 46

Page 48: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

Sample rate mode Reading rateSLOW ≈4 times/secMID ≈20 times/secFAST ≈100 times/sec

47

Specifications

5-1/2 digits, full-scale 409999 Max. sample rate 100 times/sec. (at 4-1/2 digits

mode) High resolution

DCV: 1 µV, ACV: 1 µV, Ω: 0.1 mΩ, DCA/ACA : 10 nA

TRUE RMS ACV/ACA 4-wire ohms measurement Storage of 3,000 data A variety of optional units enhance measuring

efficiency.

ResolutionRange

23±1°C,s 23±5°C, 23±5°C,Slow,Mid Fast

Input24hr 90days one year

5-1/2 4-1/2resistance

400 mV 0.0035 + 5 0.008 + 5 0.012 + 5 1 µV 10 µV1000 MΩ

4 V 0.0035 + 2 0.008 + 2 0.012 + 2 10 µV 100 µV40 V 0.004 + 5 0.012 + 5 0.016 + 5 100 µV 1 mV400 V 0.004 + 2 0.012 + 2 0.016 + 2 1 mV 10 mV ≈10 MΩ1000 V 10 mV 100 mV

Sample rate mode Reading rate NMR CMRSLOW ≈4 times/sec

>55 dB 110 dBMID ≈20 times/secFAST ≈100 times/sec 0 dB 55 dB

Range Resolution Frequency23±5°C, 23±5°C, Input90days one year resistance

400 mV 1 µV 15 Hz–45 Hz 0.5 + 100 0.5 + 1504 V 10 µV 45 Hz–100 Hz 0.25 + 100 0.25 + 150 ≈2 MΩ/40 V 100 µV 100 Hz–50 kHz 0.2 + 100 0.2 + 150 100 pF or400 V 1 mV 50 kHz–100 kHz 0.5 + 300 0.5 + 300 below750 V 10 mV

Frequency Crest factor1–1.5 1.5–2 2–3

15 Hz~20 kHz 0.05% 0.15% 0.3%20 kHz~300 kHz 0.2% — —

Sample rate mode Reading rate Frequency Response timeSLOW ≈4 times/sec 15 Hz–100 kHz 2 secFAST ≈20 times/sec 200 Hz–100 kHz 1 sec

* Response time is the time for meter reading to reach within 100 counts of final value in thesame range.

Sample rate

1. DC VOLTSAccuracy

Sample rate : SLOW/MID : ± (% of reading + digits)

* The accuracy at 23±1°C, and 24 hrs. is relative to the calibration standards.* The accuracy at 400 mV range is specified after zero compensation through the REL

operation.* Add 0.003% of reading when used with SC-306 battery unit. * In FAST sample mode, add 5 digits to the accuracy in SLOW and MID sample modes.Temperature coefficient (0°C to 18°C, 28°C to 50°C)

(1/10 of the accuracy for each range)/°CMaximum input voltage 40 mV to 4 V range : ±1100 V DC (5 sec.)

±500 V DC (continuous)40 V to 1000 V range : ±1100 V DC (continuous)

Sample rate and noise rejection

* Reading rates are specified with math function OFF.* NMR : 50/60 Hz : ±0.1%* CMR :1 kΩ unbalance, DC, 50/60 Hz : ±0.1%

2. AC VOLTSAccuracy (For sine wave only) : ±(% of reading + digits)

400 mV to 400 V range : Accuracy is specified for 20,000 counts or more.750 V range : Accuracy is specified for 10,000 counts or more.

* In the 750 V range, accuracy is specified at 20 kHz or lower.* In SLOW sample mode, accuracy is specified at 15 Hz or higher. * In FAST sample mode, accuracy is specified at 200 Hz or higher.Temperature coefficient (0°C to 18°C, 28°C to 50°C)

(1/10 of the accuracy for each range)/°CMaximum input voltage All range : 780 Vrms (continuous), 1100 V peakAC converter True RMS.

Signals other than sine wave : add the following values to the accuracy of the sine wave.

Resolution Voltage dropRange

23±5°C, 23±5°C,Slow,Mid Fast across input90days one year

5-1/2 4-1/2 terminal4 mA 10 nA 100 nA40 mA 0.05 + 5 0.08 + 7 100 nA 1 µA 600 mV400 mA 1 µA 10 µA

4000 mA2A 0.05 + 5 0.08 + 7

10 µA 100 µA 1 V>2A 0.1 + 5 0.13 + 7

40 Ω to 400 kΩ 50ms4000 kΩ 0.1s Zero to full scale within the same40 MΩ 0.5s range400 MΩ 5s

Sample rate mode Reading rateSLOW ≈4 times/sec

MID ≈20 times/secFAST 40 Ω to 4000 kΩ ≈100 times/sec

40 MΩ, 400 MΩ ≈20 times/sec

ResolutionRange

23±1°C, 23±5°C, 23±5°C,Slow,Mid Fast Test current24hrs 90days one year

5-1/2 4-1/2 40 Ω 0.01 + 10 0.02 + 10 0.025 + 10 0.1 mΩ 1 mΩ ≈10 mA400 Ω 1 mΩ 10 mΩ ≈10 mA4 kΩ 0.005 + 3 0.01 + 3 0.014 + 3 10 mΩ 100 mΩ ≈1 mA40 kΩ 100 mΩ 1 Ω ≈100 µA400 kΩ 0.006 + 3 0.011 + 3 0.015 + 3 1 Ω 10 Ω ≈10 µA4000 kΩ 0.012 + 10 0.03 + 10 0.033 + 10 10 Ω 100 Ω ≈1 µA40 MΩ 0.05 + 20 0.2 + 20 0.25 + 20 100 Ω 1 kΩ ≈100 nA400 MΩ 0.5 + 50 1.5 + 50 1.5 + 50 1 kΩ 10 kΩ ≈10 nA

3. RESISTANCE Ω (2WΩ/4WΩ)Accuracy Sample rate : SLOW/MID : ± (% of reading + digits)

* The accuracy at 23±1°C, and 24 hrs. is relative to the calibration standards.* The accuracy at 40 Ω to 4 kΩ ranges are specified after zero compensation through the

REL operation.* Add 0.003% of reading when used with SC-306 battery unit.* In FAST sample mode, add the following values to the accuracy in SLOW and MID sample

modes. 40 Ω to 4 kΩ ranges . . . . . . . 5 digits40 kΩ to 4000 kΩ ranges . . . . . 30 digits40 MΩ to 400 MΩ ranges . . . . . 10 digits

Temperature coefficient (0°C to 18°C, 28°C to 50°C)(1/10 of the accuracy for each range)/°C

Maximum input voltage ±500 V DC Between V/Ω and COM terminals, and between 4 WΩSENSE H and L terminals

Open circuit test voltage 6.8 V or less

Sample rate Sample rate and noise rejection

Response time

4. DC CURRENTAccuracy Sample rate : SLOW/MID : ± (% of reading + digits)

* In FAST sample mode, add 10 digits to the accuracy in SLOW and MID sample modes. Temperature coefficient (0°C to 18°C, 28°C to 50°C)

(1/10 of the accuracy for each range)/°C Maximum current Protected by a 4 A fuse.

4 mA to 400 mA range : 4 A DC or rms (5 sec.) 1.5 A DC or rms (continuous)

4000 mA range : 4 A DC or rms (continuous)Sample rate

<=

<=

<=<=

>=

>=

>=

VOAC 7510

<=

p41-p58 00.9.28 3:10 PM ページ 47

Page 49: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

Sample rate mode Reading rateSLOW ≈4 times/secFAST ≈20 times/sec

48

6. MATH and MISCELLANEOUS FUNCTIONS

6–1. REL and % MATH1 REL math

Y=X-A Y : Reading value X : Measurement value. A : Reference value.

2 % math Y = X/A x 100 Y : Reading value.

X : Measurement value. A : Reference value.

* The function shall be same for all values. * Full scale is + 999999 under no over-range condition. * Math ON/OFF and reference value are stored in each function. * The % indicator lights at % math function.

6-2. MAX/MIN math Maximum and minimum values are stored in the internal memory in the samefunction and the same range. * Data are read out in the RECALL mode.

6-3. AVG math Moving average of 0 to 100 times (from the keys) or 0 to 255 times (via GP-IB) is available. Setting the number of average to 0 disables AVG math function with AVGindicator off * When used in TRIG or remote mode, the AVG math is run once up to thespecified number of average.

6-4. STORE function The internal memory stores up to 3,000 data with the address from 0 to 2999. * Data are read out in the RECALL mode.

6-5. Continuity test Continuity test is available by pushing the Ω•) ) ) key at the 2 WΩ function. Threshold level : 17,000 counts ±10,000 counts Accuracy : Two times of the resistance measurement accuracy. Sample rate : Approx. 20 times/sec. * The resistance measurement is available in continuity test.

6-6. A/D converter Converting method: Triple slope integration. Integration time

SLOW/MID : 20 m sec (200 m sec) at 50Hz power line frequency16.67 m sec (200 m sec) at 60Hz Power line frequency The number in the parentheses is at DCV 40 mV range forVOAC 7512 and VOAC 7513.

FAST : 2msec at 50 Hz and 60 Hz power line frequencies. Samespecification as SLOW/ MID mode at ACV/ ACA function and 40MΩ or higher range in 2 WΩ/4 WΩ function.

* Integration time is automatically adjusted depends on the power linefrequency, when used with AC power source.

* Manual set of integration time is available, when used with DC powersource

6-7. Battery back-up The last setup before the power off including STORE data is recalled atturning power on when SET UP function is ON..

7. GENERALDisplay : 7-segment LED of 11mm height. Full scale : 409999 (A/D converter full scale)

999999 (REL math full scale) Over range display : UUUUUUConverting method : Drift compensated triple slope integration. Polarity indication : “—” indication at negative polarity. Range selection : AUTO/MANUAL or remote control by using option

unit. AUTO ranging : Range up when more than 409999 counts.

Range down when less than 036000 counts. Function selection : MANUAL or remote control by using option unit.Withstand voltage : ±500 V DC (between COM input and ground

terminals) Power supply : AC100V ±10% 50/60 Hz or battery operation by

using SC-306 option unit. Option : AC117V, 217V, or 234VPower consumption : Less than 8W without option unit Operating temperature : 0°C to 50°COperating humidity : Less than 80% RH (0°C to 40°C)

Less than 60% RH (40°C to 50°C) Warm up time : 1hour after turning power on. Dimensions : Approx. 191 (W) x 80 (H) x 260 (L) mm Weight : Approx. 1.9 kg Accessories : Power code (1), Test lead (1 set). Fuses (4),

Alignment screw driver (1), Accessory bag (1),Instruction manual (1)

5. AC CURRENTAccuracy 23±5°C, one year

Accuracy is specified for 20,000 counts or more: ± (% of reading + digits)

* Accuracy is specified at 15 Hz or higher in SLOW and 200 Hz or higher in FAST samplemode.

* DC component must be smaller than five times of the range.Temperature coefficient (0°C to 18°C, 28°C to 50°C)

(1/10 of the accuracy for each range)/°CAC converter True RMS.Maximum current Protected by a 4 A fuse.

4 mA to 400 mA range : 4 A DC or rms (5 sec.) 1.5 A DC or rms (continuous)

4000 mA range : 4 A DC or rms (continuous)Signals other than sine wave : Add the following values to the accuracy of the sine wave

Sample rate

Range Resolution Frequency Accuracy Voltage drop across(Sine wave only) input terminal

4 mA 10 nA40 mA 100 nA 15 Hz–45 Hz 1.0 + 200 600 mVrms400 mA 1 µA 45 Hz–1 kHz 0.4 + 2004000 mA 1 µA 1 Vrms

Frequency Crest factor1–1.5 1.5–2 2–3

15 Hz~1 kHz 0.05% 0.15% 0.3%

<=

<=

p41-p58 00.9.28 3:10 PM ページ 48

Page 50: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

49

1. DC voltage measurement DCV

Accuracy ± (% of reading + digits)Range Resolution (23~5°C, 80% Rh or less) Input resistance

SLOW / MID FAST40 mV 1 µV 0.04 + 5 0.06 + 20 100 MΩ or more400 mV 10 µV 1000 MΩ or more4 V 100 µV40 V 1 mV 0.04 + 2 0.06 + 7400 V 10 mV Approx. 10 MΩ1000 V 100 mVTemperature coefficient 0°C – 18°C, 28°C – 50°C (Accuracy in the range x 1/10)/°CMax. allowable voltage40 mV – 4 V range +1100 V DC (10 sec), +500 V DC (continuous)40 V – 100 V range ±1100 V DC (continuous)CMR 110 dB or more

(1 kΩ unbalanced resistance, DC, 50/60 Hz ±0.1%.) NMR SLOW ,MID: 55 dB or more (1 kΩ unbalanced resistance,

50/60 Hz ±0.1%) FAST: 0 dB

2. AC voltage measurement ACV AC function : Input exceeding 5%. or more of the range (in the 750 V range 100 V or more)

Range Resolution FrequencyAccuracy ± (% of reading + digits)

(23+5°C, 80% Rh or less)400 mV 10 µV 20 Hz–50 Hz 0.4 + 30*4 V 100 µV 50 Hz–10 kHz 0.2 + 30*40 V 1 mV 10 kHz–30 kHz 0.3 + 30400 V 10 mV 30 kHz–100 kHz 1.2 + 100750 V 100 mV 20 Hz–20 kHz 0.3 + 15*

*In the MID sampling mode, accuracy is guaranteed at 200 Hz or more.

AC + DC function : Input exceeding 5%. or more of the range (in the 750 V range 100 V or more)

Range Resolution FrequencyAccuracy ± (% of reading + digits)

(23+5°C, 80% Rh or less)400 mV 10 µV 15 Hz–50 Hz 0.4 + 40*4 V 100 µV 50 Hz–10 kHz 0.2 + 40*40 V 1 mV 10 kHz–30 kHz 0.3 + 40400 V 10 mV 30 kHz–100 kHz 1.2 + 110750 V 100 mV 15 Hz–20 kHz 0.3 + 30*Temperature coefficient 0°C to 18°C, 28°C to 50°C 400 mV – 400 V range

(1/10 of each range and frequency/°C 750 V range (0.1% of rdg ±7 d)/°C

Conversion method True rms (analog computation)Crest factor 3 or less (full scale)Input Impedance Approx. 2 MΩ// 100 pF or lessMax. allowable voltage 780 Vrms (continuous) 1100V peakResponse time (In the same SLOW: Max. 2 sec (20 Hz to 100 kHz)range, within ±10 counts MID: Max. 1 sec (200 Hz to 100 kHz)from the final value)

3. Resistance measurement ΩΩ function

Accuracy ± (% of reading + digits)Range Resolution (23~5°C, 80% Rh or less) Input resistance

SLOW MID FAST40 Ω* 1 mΩ 0.08 + 5 10 mA400 Ω* 10 mΩ 0.1 + 10 10 mA4 kΩ* 100 mΩ 100 µA40 kΩ 1 Ω 0.06 + 2 100 µA400 kΩ 10 Ω 0.1 + 40 10 µA4000 kΩ 100 Ω 0.10 + 2 0.2 + 100 1 µA40 MΩ 1 kΩ 0.40 + 5 — 100 nA 400 MΩ 10 kΩ 4.00 + 20 — 10 nA

* In the 40, 400, 4 kΩ ranges, accuracy is given after zero Ω adjustment by RELcomputation.

L0-Ω functionAccuracy ± (% of reading + digits)

Range Resolution (23±5°C 80%. Rh or less) Measuring currentSLOW /MID FAST

400 Ω* 10 mΩ 100 µA4 kΩ* 100 mΩ 0.2 + 5 0.3 + 60 100 µA40 kΩ 1 Ω 10 µA400 kΩ 10 Ω 0.4 + 300 1 µA4000 kΩ 100 Ω 0.4 + 10 — 100 nA40 MΩ 1 kΩ 3.0 + 30 — 10 nA

* In the 400, 4 kΩ ranges, accuracy is given after zero Ω adjustment by REL computation.

Temperature coefficient 0°C to 18°C, 28°C to 50°CΩ 40 Ω to 4000 kΩ, LO-Ω 400 Ω to 400 kΩ range (Accuracy in the range or rate x 1/10)/°CΩ 40 MΩ to 400 MΩ, LO-Ω 4000 kΩ to 400 MΩ range (Accuracy in the range or rate x 1/10) ±(0.1% of rdg ± 3 d)/°C

Terminal open-circuit voltage 6.8 V or lessMax. protective voltage ±500 V DC

4. DC current measurement DCA

Accuracy ± (% of reading + digits) Voltage drop acrossRange Resolution (23 + 5°C, 80%. Rh or less) input terminals

SLOW / MID FAST (full scale)400 µA 10 nA 500 mV or less4 mA 100 nA40 mA 1 µA 0.2 + 5 0.2 + 20400 mA 10 µA 1.1 V or less4 A 100 µA 200 mV or less10 A 1 mA 0.2 + 5 0.2 + 15Temperature coefficient 0°C to 18°C, 28°C to 50°C

(Accuracy in the range or rate x1/10)/°CMax. allowable current 400 µA to 400 mA range: 0.5 A DC (continuous),

4 A, 10 A range: 10 A DC (continuous)Auto ranging Possible only for the same input terminals

(not possible with auto ranging between 400 mA and 4 A range)*In the MID sampling mode, accuracy is guaranteed at 200 Hz or more.

Full-scale 40999, Max. sample rate 100times/s, 4-1/2 digits Temperature measurement: –50°C to +1370°C Power measurement up to 2500 W DCV, ACV, Ω, DCA, ACA,°C, Hz, W True RMS ACV/ACA AVG (averaging)

This function is very effective for measurementswhen there is a high variance. Averaging 5, 10,20, 50 and 100 times can be selected using theAVG n button.

REL (relative)The relative value with respect to a referencevalue is indicated, and the deviation and externalthermoelectromotive force in low-voltagemeasurements can be eliminated by single-touchoperations.

VOAC-7413

Specifications

p41-p58 00.9.28 3:10 PM ページ 49

Page 51: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

50

Arithmetic operations Max/min operation

Maximum and minimum values of measured value can be stored inmemory within the same function and range.

Data storage Addresses are assigned together with function, range and presence /absence of arithmetic operations for up to 1000 measured data then heldin memory. The stored data can be read using the REC key.

Averaging (shift averaging) The shift averaging of 5, 10, 20, 50 and 100 times is performed. When theGP-IB unit is used, averaging from 2 to 255 times can be specified using acommand.

REL operation The relative value with respect to the reference measured value isindicated.Y = X-A (X and Y are the same function) where A: reference measured value

X: measured value

Continuity test Range Same as resistance measurement Threshold value: 1700 ±1000 counts Accuracy in measurement (Accuracy in resistance measurement) x 2 Sampling rate Approx. 20 times/sec fixed

Others A/D conversion

Converting method: Triple integration Input integrating time SLOW/MID: 20 msec during 50 Hz

16.67 msec during 60 Hz FAST: 2 msec (50/60 Hz)

In the AC operation, 50/60 Hz is automatically set.50 or 60 Hz can also be set using the LINE f key.

Battery backup When the setup is on, the multimeter is automatically set to the previous statewhen the power is switched on.

What are to be backed up include • Functions when the power is switched OFF • Arithmetic ON/OFF, sampling rate per function • Number of averaging in AVG operation • Standard measured value in REL operation • Stored address, stored data (VOAC 7413)

General specifications Indication 7-segment LED, letter height 11 mm Full scale 40999 (A/D conversion full scale)

99999 (REL operation full scale) Over indication UUUUU (A/D conversion/operation over) Operation method Drift compensation type triple integration Polarity indication “–” is indicated when the polarity is negative Range selection AUTO/MANUAL or external control (when

an optional unit is used) Function selection MANUAL or external control (when an

optional unit is used) Auto ranging UP level: when 40999 counts is exceeded

DOWN level: less than 03600 counts Withstand voltage ±500 V DC Power requirements AC100V ±10%, 50/60 Hz

Options 117V, 217V or 234V AC Power consumption 6 W or less Operating temperature range 0°C to 50°C Operating humidity range 80% Rh or less (0°C to 40°C)

60% Rh or less (40°C to 50°C) Dimensions 191 ±2 W x 80 ±2 H x 260 ±2 L mm Weight Approx. 1.8 kg Accessories Power cord (1), fuse (4), measuring leads

(one set), alignment tool (1), bag to storeaccessories (1), instruction manual (1)

5. AC current measurement ACAAC function : Input exceeding 5% of the range (1A or more in the 10A range)

7. Power measurement Range 1 range on y

Measuring range 0 – 2500 WInput range Voltage 85 – 250 (V) (40 Hz – 400 Hz),

Current 0 – 10 (A) (40 Hz – 400 Hz)Input characteristics DC-coupled 3-wire input (V, A, COM)

V: (DC + AC)V same as 400V range, Crest factor: 2 or lessA: (DC + AC)A same as 400V range, Crest factor: 3 or less

Conversion method Analog computation methodAccuracy 100V line 0.5 + 20 (cos φ =1, 40 Hz – 70 Hz), ± (% of reading + digits) 1.0 + 30 (cos φ =1, 70 Hz - 400 Hz)

200V line 0.7 + 30 (cos φ = 1 , 40 Hz - 70 Hz), 1.2 + 40 (cos φ =1, 70 Hz - 400 Hz)Influence of power factor: within ±0.5% or rdg(cos φ = ±0.5, 50/60 Hz)

Temperature coefficient 0°C to 18°C, 28°C to 50°C (±0.08%. of rdg ±3d)/°C

Accuracy ± (% of reading + digits) Voltage drop across Range Resolution (23 ± 5°C, 80% Rh or less) input terminals

15 Hz – 50 Hz* 50 Hz – 1 kHz* (full scale)400 µA 10 nA4 mA 100 nA

0.7 + 30 0.5 + 30500 mVrms or less

40 mA 1 µA400 mA 10 µA 1.1 Vrms or less4 A 100 µA

1.0 + 30 0.7 + 30 200 mVrms or less10 A 1 mA

6 Temperature measurement °C (range: 1 range only)

Range ResolutionAccuracy ± (% of reading + digits)

(23 ± 5°C, 80% Rh or less)–50°C – +1370°C 0.1°C –50°C – +256°C 0.1 + 15

+256°C – +1370°C 0.1 + 20Temperature 0°C to 18°C, 28°C to 50°C ±0.1°C/°CcoefficientThermocouple Type K (JIS) used

Function SLOW MID FASTDCV DCA Approx. 4 times sec Approx. 20 times sec Approx. 100 times secHI-Ω Lo-ΩACV ACA Approx. 4 times sec Approx. 20 times sec —°C Approx. 2 times sec Approx. 10 times sec —W Approx. 1 times sec — —

Sampling rate

*In the MID sampling mode, accuracy is guaranteed at 200 Hz or more

AC + DC function : Input exceeding 5% of the range (1A or more in the 10A range)

Accuracy ± (% of reading + digits) Voltage drop across Range Resolution (23 ± 5°C, 80% Rh or less) input terminals

15 Hz – 50 Hz* 50 Hz – 1 kHz* (full scale)400 µA 10 nA4 mA 100 nA

0.7 + 40 0.5 + 40500 mVrms or less

40 mA 1 µA400 mA 10 µA 1.1 Vrms or less4 A 100 µA

1.0 + 40 0.7 + 40 200 mVrms or less10 A 1 mATemperature coefficient 0°C to 18°C, 28°C to 50°C

(Accuracy in the range or frequency x 1/10) °CConversion method True rms (analog computation)Crest factor 3 or less (full scale)Max. allowable current 400 µA to 400 mA range: 0.5 A DC + AC (continuous),

4 A, 10 A range: 10 A DC + AC (continuous)Auto ranging Possible only for the same input terminals

(not possible with auto ranging between 400 mA and 4 A range)

Response time (in the same SLOW: Max. 2 sec (20 Hz – 1 kHz)range, within + 10 counts MID: Max. 1 sec (200 Hz – 1 kHz)from the final value)

*The accuracy of the thermocouple is not included

*In the MID sampling mode, accuracy is guaranteed at 200 Hz or more

p41-p58 00.9.28 3:10 PM ページ 50

Page 52: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

51

1. DC voltage measurement DCV

2. AC voltage measurement ACV

Range Resolution FrequencyAccuracy ± (% of reading + digits)

(23+5°C, 80% Rh or less)400 mV 10 µV 20 Hz–50 Hz 0.4 + 15*4 V 100 µV 50 Hz–10 kHz 0.2 + 15*40 V 1 mV 10 kHz–30 kHz 0.3 + 20400 V 10 mV 30 kHz–100 kHz 1.2 + 40750 V 100 mV 20 Hz–20 kHz 1.3 + 15*

* In the MID sampling mode, accuracy is guaranteed at 200 Hz or more.

Temperature coefficient 0°C to 18°C, 28°C to 50°C 400 mV – 400 V range (1/10 of each range and frequency/°C 750 V range (0.1% of rdg ±7 d)/°C

Conversion method True rms (analog computation)Input Impedance Approx. 2 MΩ// 100 pF or lessMax. allowable voltage 780 Vrms (continuous) 1100V peakResponse time (In the same SLOW: Max. 2 sec (20 Hz to 100 kHz)range, within ±10 counts MID: Max. 1 sec (200 Hz to 100 kHz)from the final value)

3. Resistance measurement ΩΩ function

* In the 40, 400, 4 kΩ ranges, accuracy is given after zero Ω adjustment by RELcomputation.

L0-Ω function

* In the 400, 4 kΩ ranges, accuracy is given after zero Ω adjustment by REL computation.

4. DC current measurement DCA

Accuracy ± (% of reading + digits)Range Resolution (23~5°C, 80% Rh or less) Input resistance

SLOW / MID FAST40 mV 1 µV 0.04 + 5 0.06 + 20 100 MΩ or more400 mV 10 µV

1000 MΩ or more4 V 100 µV40 V 1 mV 0.04 + 2 0.06 + 7400 V 10 mV Approx. 10 MΩ1000 V 100 mVTemperature coefficient 0°C – 18°C, 28°C – 50°C (Accuracy in the range x 1/10)/°CMax. allowable voltage40 mV – 4V range +1100 V DC (10 sec), +500 V DC (continuous)40V – 100V range ±1100 V DC (continuous)CMR 110 dB or more

(1 kΩ unbalanced resistance, DC, 50/60 Hz ±0.1%.) NMR SLOW ,MID: 55 dB or more (1 kΩ unbalanced resistance,

50/60 Hz ±0.1%)FAST: 0 dB

Accuracy ± (% of reading + digits)Range Resolution (23~5°C, 80% Rh or less) Input resistance

SLOW MID FAST40 Ω* 1 mΩ 0.08 + 5 10 mA400 Ω* 10 mΩ

0.1 + 1010 mA

4 kΩ* 100 mΩ 100 µA40 kΩ 1 Ω

0.06 + 2100 µA

400 kΩ 10 Ω 0.1 + 40 10 µA4000 kΩ 100 Ω 0.10 + 2 0.2 + 100 1 µA40 MΩ 1 kΩ 0.40 + 5 — 100 nA 400 MΩ 10 kΩ 4.00 + 20 — 10 nA

Accuracy ± (% of reading + digits)Range Resolution (23±5°C 80%. Rh or less) Measuring current

SLOW /MID FAST400 Ω* 10 mΩ 100 µA4 kΩ* 100 mΩ

0.2 + 50.3 + 60 100 µA

40 kΩ 1 Ω 10 µA400 kΩ 10 Ω 0.4 + 300 1 µA4000 kΩ 100 Ω 0.4 + 10 — 100 nA40 MΩ 1 kΩ 3.0 + 30 — 10 nA

Temperature coefficient 0°C to 18°C, 28°C to 50°CΩ 40 Ω to 4000 kΩ, LO-Ω 400 Ω to 400 kΩ range (Accuracy in the range or rate x 1/ 10)/°CΩ 40 MΩ to 400 MΩ, LO-Ω 4000 kΩ to 400 MΩ range (Accuracy in the range or rate x 1/10) ±(0.1% of rdg ± 3 d)/°C

Terminal open-circuit voltage 6.8 V or lessMax. protective voltage ±500 V DC

Accuracy ± (% of reading + digits) Voltage drop acrossRange Resolution (23 + 5°C, 80%. Rh or less) input terminals

SLOW / MID FAST (full scale)400 µA 10 nA4 mA 100 nA 500 mV or less40 mA 1 µA 0.2 + 5 0.2 + 20400 mA 10 µA 1.1 V or less4 A 100 µA

200 mV or less10 A 1 mA 0.2 + 5 0.2 + 15Temperature coefficient 0°C to 18°C, 28°C to 50°C

(Accuracy in the range or rate x1/10)/°CMax. allowable current 400 µA to 400 mA range: 0.5 A DC (continuous),

4 A, 10 A range: 10 A DC (continuous)Auto ranging Possible only for the same input terminals

(not possible with auto ranging between 400 mA and 4 A range)

Full-scale 40999, Max. sample rate 100times/s, 4-1/2 digits Temperature measurement: –50°C to +1370°C DCV, ACV, Ω, DCA, ACA,°C, Hz Average RMS ACV/ACA P-P (sine) measurement AVG (averaging)

This function is very effective for measurementswhen there is a high variance. Averaging 5, 10,20, 50 and 100 times can be selected using theAVG n button.

REL (relative)The relative value with respect to a referencevalue is indicated, and the deviation and externalthermoelectromotive force in low-voltagemeasuremens can be eliminated by single-touchoperations.

VOAC-7412

Specifications

p41-p58 00.9.28 3:10 PM ページ 51

Page 53: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

52

5. AC current measurement ACA

*In the MID sampling mode, accuracy is guaranteed at 200 Hz or more

Temperature coefficient 0°C to 18°C, 28°C to 50°C (Accuracy in the range or frequency x 1/10) °C

Conversion method True rms (analog computation)Max. allowable current 400 µA to 400 mA range: 0.5A DC + AC (continuous),

4 A, 10 A range: 10 A DC + AC (continuous)Auto ranging Possible only for the same input terminals

(not possible with auto ranging between 400 mA and 4 A range)

Response time (in the same SLOW: Max. 2 sec (20 Hz – 1 kHz)range, within + 10 counts MID: Max. 1 sec (200 Hz – 1 kHz)from the final value)

6 Temperature measurement °C (range: 1 range only)

Sampling rate

Range Max.Accuracy

Input(auto range only)

± (% of reading + digits)resolution

(23±5°C, 80%Rh or less)sensitivity

10 Hz–40 Hz 0.001 Hz40 Hz–400 Hz 0.01 Hz 50 mV400 Hz–4 kHz 0.1 Hz

0.05 + 2(400 mV range)

4 kHz–40 kHz 1 Hz40 kHz–200 kHz 10 Hz 200 mV

(400 mV range)Temperature coefficient 0°C to 18°C 28°C to 50°C ±0.5 digit/°CMeasuring method Reciprocal methodInput attenuator Selected by the range key 400 mV range to 400 V range

Arithmetic operations P-P operation

The peak-to-peak value of the input can be obtained when measuring ACVand ACA

Y = 2u2 • X Y: Indication

X: Measured value * Digits other than those indicated are rounded off.

Averaging (shift averaging) The shift averaging of 5, 10, 20, 50 and 100 times is performed. When theGP-IB unit is used, averaging from 2 to 255 times can be specified using acommand.

REL operation The relative value with respect to the reference measured value isindicated.Y = X-A (X and Y are the same function) where A: reference measured value

X: measured value

Continuity test Range Same as resistance measurement Threshold value: 1700 ±1000 counts Accuracy in measurement (Accuracy in resistance measurement) x 2 Sampling rate Approx. 20 times/sec fixed

Others A/D conversion

Converting method: Triple integration Input integrating time SLOW/MID: 20 msec during 50 Hz

16.67 msec during 60 Hz FAST: 2 msec (50/60 Hz)

In the AC operation, 50/60 Hz is automatically set.50 or 60 Hz can also be set using the LINE f key.

Battery backup When the setup is on, the multimeter is automatically set to the previous statewhen the power is switched on.

What are to be backed up include • Functions when the power is switched OFF • Arithmetic ON/OFF, sampling rate per function • Number of averaging in AVG operation • Standard measured value in REL operation

General specifications Indication 7-segment LED, letter height 11 mm Full scale 40999 (A/D conversion full scale)

99999 (REL operation full scale) Over indication UUUUU (A/D conversion/operation over) Operation method Drift compensation type triple integration Polarity indication “–” is indicated when the polarity is negative Range selection AUTO/MANUAL or external control (when

an optional unit is used) Function selection MANUAL or external control (when an

optional unit is used) Auto ranging UP level: when 40999 counts is exceeded

DOWN level: less than 03600 counts Withstand voltage ±500 VDC Power requirements AC100V ±10%, 50/60 Hz

Options 117V, 217V or 234V AC Power consumption 6 W or less Operating temperature range 0°C to 50°C

Operating humidity range 80% Rh or less (0°C to 40°C) 60% Rh or less (40°C to 50°C)

Dimensions 191 ±2W x 80±2H x 260±2L mm Weight approx. 1.8 kg Accessories Power cord (1), fuse (4), measuring leads

(one set), alignment tool (1), bag to store accessories (1), Instructionmanual (1)

*The accuracy of the thermocouple is not included

7. Frequency measurement Hz

Accuracy ± (% of reading + digits) Voltage drop across Range Resolution (23 ± 5°C, 80% Rh or less) input terminals

20 Hz – 50 Hz* 50 Hz – 1 kHz* (full scale)400 µA 10 nA4 mA 100 nA

0.5 + 20 0.4 + 20500 mVrms or less

40 mA 1 µA400 mA 10 µA 1.1 Vrms or less4 A 100 µA

0.8 + 20 0.5 + 20 200 mVrms or less10 A 1 mA

Range Resolution Accuracy ± (% of reading + digits)(23 ± 5°C, 80% Rh or less)

–50°C – +1370°C 0.1°C –50°C – +256°C 0.1 + 15+256°C – +1370°C 0.1 + 20

Temperature 0°C to 18°C, 28°C to 50°C ±0.1°C/°CcoefficientThermocouple Type K (JIS) used

Function SLOW MID FASTDCV DCA Approx. 4 times sec Approx. 20 times sec Approx. 100 times secHI-Ω Lo-ΩACV ACA Approx. 4 times sec Approx. 20 times sec —Hz Approx. 2.5 times sec — —°C Approx. 2 times sec Approx. 10 times sec —

p41-p58 00.9.28 3:10 PM ページ 52

Page 54: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

53

1. DC voltage measurement DCV

Range ResolutionAccuracy ± (% of reading + digits)

Input resistance(23~5°C, 80% Rh or less)

40 mV 1 µV 0.08 + 7 100 MΩ or more400 mV 10 µV

1000 MΩ or more4 V 100 µV40 V 1 mV 0.07 + 2400 V 10 mV Approx. 10 MΩ1000 V 100 mVTemperature coefficient 0°C – 18°C, 28°C – 50°C

(Accuracy in the range x 1/10)/˚CMax. allowable voltage40 mV – 4V range +1100 V DC (10 sec), +500 V DC (continuous)40V – 100V range ±1100 V DC (continuous)CMR 110 dB or more

(1 kΩ unbalanced resistance, DC, 50/60 Hz ±0.1%.) NMR 55 dB or more

(1 kΩ unbalanced resistance 50/60 Hz ±0.1%)

2. AC voltage measurement ACV AC function : Input exceeding 5%. or more of the range(in the 750 V range 100V or more)

* In the FAST sampling mode, accuracy is guaranteed at 200 Hz or more.

AC + DC function : Input exceeding 5%. or more of the range (in the 750 V range 100 V or more)

3. Resistance measurement ΩΩ function

Range ResolutionAccuracy ± (% of reading + digits)

Measuring current(23±5°C 80%. Rh or less)

40 Ω 1 mΩ 0.09 + 4 10 mA400 Ω 10 mΩ 10 mA4 kΩ 100 mΩ 100 µA40 kΩ 1 Ω

0.08 + 2100 µA

400 kΩ 10 Ω 10 µA4000 kΩ 100 Ω 0.12 + 2 1 µA40 MΩ 1 kΩ 0.50 + 5 100 nA 400 MΩ 10 kΩ 5.00 + 20 10 nA

* In the 40, 400, 4 kΩ ranges, accuracy is given after zero Ω adjustment by RELcomputation.

L0-Ω function

Range ResolutionAccuracy ± (% of reading + digits)

Measuring current(23±5°C 80%. Rh or less)

400 Ω* 10 mΩ 100 µA4 kΩ* 100 mΩ

0.3 + 5100 µA

40 kΩ 1 Ω 10 µA400 kΩ 10 Ω 1 µA4000 kΩ 100 Ω 0.5 + 10 100 nA40 MΩ 1 kΩ 3.5 + 30 10 nA

Temperature coefficient 0°C to 18°C, 28°C to 50°CΩ 40 Ω to 4000 kΩ, LO-Ω 400 Ω to 400 kΩ range (Accuracy in the range or rate x 1/ 10)/˚CΩ 40 MΩ to 400 MΩ, LO-Ω 4000 kΩ to 400 MΩ range (Accuracy in the range or rate x 1/10) ±(0.1% of rdg ± 3 d)/°C

Terminal open-circuit voltage 6.8 V or lessMax. protective voltage ±500 V DC

4. DC current measurement DCAAccuracy Voltage drop across

Range Resolution ± (% of reading + digits) input terminals(23 + 5°C, 80%. Rh or less) (full scale)

400 µA 10 nA4 mA 100 nA

0.2 + 7500 mV or less

40 mA 1 µA400 mA 10 µA 1.1 V or less4 A 100 µA 0.3 + 710 A 1 mA 0.4 + 5

200 mV or less

Temperature coefficient 0°C to 18°C, 28°C to 50°C (Accuracy in the range or rate x1/10)/°C

Max. allowable current 400 µA to 400 mA range: 0.5 A DC (continuous), 4 A, 10 A range: 10 A DC (continuous)

Auto ranging Possible only for the same input terminals(not possible with auto ranging between 400 mA and 4 A range)

* In the 400, 4 kΩ ranges, accuracy is given after zero Ω adjustment by REL computation.

Full-scale 40999, Max. sample rate 20times/s, 4-1/2 digits DCV, ACV, Ω, DCA, ACV True RMS ACV/ACA Maximum sampling rate: 20 times/sec. AVG (averaging)

This function is very effective for measurementswhen there is a high variance. Averaging 5, 10,20, 50 and 100 times can be selected using theAVG n button.

REL (relative)The relative value with respect to a referencevalue is indicated, and the deviation and externalthermoelectromotive force in low-voltagemeasuremens can be eliminated by single-touchoperations.

VOAC-7411

Range Resolution FrequencyAccuracy ± (% of reading + digits)

(23+5°C, 80% Rh or less)400 mV 10 µV 20 Hz–50 Hz 0.5 + 30*4 V 100 µV 50 Hz–10 kHz 0.25 + 30*40 V 1 mV 10 kHz–30 kHz 0.4 + 30400 V 10 mV 30 kHz–100 kHz 1.2 + 100750 V 100 mV 20 Hz–20 kHz 1.5 + 30*

Range Resolution FrequencyAccuracy ± (% of reading + digits)

(23+5°C, 80% Rh or less)400 mV 10 µV 15 Hz–50 Hz 0.5 + 40*4 V 100 µV 50 Hz–10 kHz 0.25 + 40*40 V 1 mV 10 kHz–30 kHz 0.4 + 40400 V 10 mV 30 kHz–100 kHz 1.2 + 100750 V 100 mV 15 Hz–20 kHz 0.5 + 30*Temperature coefficient 0°C to 18°C, 28°C to 50°C 400 mV – 400 V range

(1/10 of each range and frequency/°C 750 V range (0.1% of rdg ±7 d)/°C

Conversion method True rms (analog computation)Crest factor 3 or less (full scale)Input Impedance Approx. 2 MΩ// 100 pF or lessMax. tolerable voltage 780 Vrms (continuous) 1100V peakResponse time (In the same SLOW: Max. 2 sec (20 Hz to 100 kHz)range, within ±10 counts FAST: Max. 1 sec (200 Hz to 100 kHz)from the final value)

Specifications

* In the FAST sampling mode, accuracy is guaranteed at 200 Hz or more.

p41-p58 00.9.28 3:10 PM ページ 53

Page 55: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

54

5. AC current measurement ACAAC function : Input exceeding 5% of the range (1A or more in the 10A range)

Accuracy ± (% of reading + digits) Voltage drop across Range Resolution (23 ± 5°C, 80% Rh or less) input terminals

20 Hz – 50 Hz* 50 Hz – 1 kHz* (full scale)400 µA 10 nA4 mA 100 nA

0.8 + 30 0.6 + 30500 mVrms or less

40 mA 1 µA400 mA 10 µA 1.1 Vrms or less4 A 100 µA10 A 1 mA

1.5 + 30 1.2 + 30 200 mVrms or less

* In the FAST sampling mode, accuracy is guaranteed at 200 Hz or more.

Sampling rateSLOW approx. 4 times sec FAST approx. 20 times sec

DC + AC function : Input exceeding 5% of the range (1A or more in the 10A range)

Accuracy ± (% of reading + digits) Voltage drop across Range Resolution (23 ± 5°C, 80% Rh or less) input terminals

20 Hz – 50 Hz* 50 Hz – 1 kHz* (full scale)400 µA 10 nA4 mA 100 nA

0.8 + 40 0.6 + 40500 mVrms or less

40 mA 1 µA400 mA 10 µA 1.1 Vrms or less4 A 100 µA10 A 1 mA

1.5 + 40 1.2 + 40 200 mVrms or less

Temperature coefficient 0°C to 18°C, 28°C to 50°C (Accuracy in the range or frequency x 1/10) °C

Conversion method True rms (analog computation)Crest factor 3 or less (full scale)Max. allowable current 400 µA to 400 mA range: 0.5 A DC + AC (continuous),

4 A, 10 A range: 10 A DC + AC (continuous)Auto ranging Range shift between 400 mA and

4 A ranges Is not possibleResponse time (in the same SLOW: Max. 2 sec (20 Hz - 1 kHz)range, within + 10 counts FAST: Max. 1 sec (200 Hz - 1 kHz)

from the final value)

Arithmetic operations Averaging (shift averaging)

The shift averaging of 5, 10, 20, 50 and 100 times is performed. When theGP-IB unit is used, averaging from 2 to 255 times can be specified using acommand.

REL operation The relative value with respect to the reference measured value isindicated.Y = X-A (X and Y are the same function) where A: reference measured value

X: measured value

Continuity test Range Same as resistance measurement Threshold value: 1700 ±1000 counts Accuracy in measurement (Accuracy in resistance measurement) x 2 Sampling rate Approx. 20 times/sec fixed

Others A/D conversion

Converting method: Triple integration Input integrating time SLOW/FAST: 20 msec during 50 Hz

16.67 msec during 60 Hz In the AC operation, 50/60 Hz is automatically set.50 or 60 Hz can also be set using the LINE f key.

Battery backup When the setup is on, the multimeter is automatically set to the previous statewhen the power is switched on.

What are to be backed up include • Functions when the power is switched OFF • Arithmetic ON/OFF, sampling rate per function • Number of averaging in AVG operation • Standard measured value in REL operation

General specifications Indication 7-segment LED, letter height 11 mm

Full scale 40999 (A/D conversion full scale) 99999 (REL operation full scale)

Over indication UUUUU (A/D conversion/operation over) Operation method Drift compensation type triple integration Polarity indication “–” is indicated when the polarity is negative Range selection AUTO/MANUAL or external control

(when an optional unit is used) Function selection MANUAL or external control (when an

optional unit is used) Auto ranging UP level: when 40999 counts is exceeded

DOWN level: less than 03600 counts Withstand voltage ±500 VDC Power requirements AC100V ±10%, 50/60 Hz

Options 117V, 217V or 234V AC Power consumption 6 W or less Operating temperature range 0°C to 50°C Operating humidity range 80% Rh or less (0°C to 40°C)

60% Rh or less (40°C to 50°C) Dimensions 191 ±2W x 80±2H x 260±2L mm Weight approx. 1.8 kg Accessories Power cord (1), fuse (4), measuring leads

(one set), alignment tool (1), bag to storeaccessories (1), Instruction manual (1)

p41-p58 00.9.28 3:10 PM ページ 54

Page 56: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

55

Optional units for the digital multimeterPowerful and compact units (available for VOAC 7500/7400 series)Any of these units can be attached with one-touch operation. Any of these units are electrically isolated from the multimeter (withstand input voltage 500V) (SC-303A to 305A)Using microprocessor control, these units are designed to be multifunctional. (SC-302A to 305A)

Arithmetic functions Stored data printing Timer measurement Max./Min. measurement printing Limit judgment

Specifications

PrinterPrinting methods ThermalNumber of characters 16 characters/linePrinting speed 0.8 ±0.2 sec/linePaper Thermal paper roll

TP50ks 4 A 38 mm x 20 m Print times Approx. 5000 lines

Print format HeaderTime unitMeasuring Function Math item

DataLapse timeLimit judgment resultsMeasured value

Print modes 0: NORMAL Printing is done regardless of limit judgment results 1: GO Printing is done when the limit judgment results are GO. 2: ALARM Printing is done when the limit judgment results are either

Hl or LO. 3: n.SAMPLE Measurement are done n times then printed out (n=input

parameter) 4: STORE Any address data from stored 3000 data is printed out.

The address is set by STORE ADR parameter.

Print data (1) Measurement data with decimal point and unit. (2) Limit judgment result, math operation result (3) Time, data number or recall data address

Setting unit and decimal point for printoutOther than standard unit set up, it is possible to change the unit and decimalpoint using the digital switch on the rear panel. Using (X-A) x B operation, thedata of the multimeter is scaled, and can be converted into other unit.

Limit judgment Critera 6-digit values between ±000000 to ±999999 set by

the Hl Limit or LO Limit parameter.Conditions Hl : measured data > Hl LIMIT

GO : Hl LIMIT measured data LO LIMIT LO : measured data < LO LIMIT

Buzzer Hl, GO or LO LED lamp comes on.When the judgment result is GO, the buzzer soundsfor approx. 30 ms.

Output +30 V DC max. +50 mA DC max.

Math operation Type 0 : No arithmetic operation

1 : (X-A) x B X : data A : Constant ±0.000001 to ±999999. B : Constant ±00.00001 to ±99.9999 (fixed

decimal point) 2 : Maximum, Minimum, Average 3 : Maximum, minimum and average values after

(X-A) x B math operation Full scale ±99999

Timer Time interval Continuous (from 0000), 01 to 59 sec or 01 to 99 min,

in 1 sec or 1 minute increment. Accuracy Within 25 seconds per 99 minutes.

Generals Power supply Supplied from the multimeter Power consumption 13W or less (including the multimeter) Withstand voltage ±500 VDC (between the COM terminal of the

multimeter and the output connector) Dimensions 191W x 65.5H x 65.5L (mm) Weight Approx. 500 g (with roll paper) Operating temperature 0°C to 40°C, 80% Rh or less Accessories Connector plug 57-30140 (1), thermal paper

TP 50ks-4A 38 x 20 m(2), roll paper bin (1),alignment screwdriver (1), instruction manual(1)

>= >=

SC-302A Printer Unit

p41-p58 00.9.28 3:10 PM ページ 55

Page 57: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

56

Unit address 31 addresses from 0 to 30 As a delimiter, CR, LF, or CRLF can be selected.

External trigger input TTL level, negative logic

Power supply Supplied from the multimeter Power consumption 12 W or less (including the multimeter) Withstand voltage ±500 VDC (between the multimeter COM

terminal and output connectors) Dimensions 191W X 65.5H X 65.5L (mm) Operating temperature 0°C to 40°C, 80% Rh or less;

40°C to 50°C, 60% Rh or lessAccessory Instruction manual (1)

Specifications

SC-303A GP-IB Unit

Full remote control External TRIG input connector Data transport

Type Code Function

Control command C Device clear

G Measurement start

Fn Function

Measuring Rn Range

Sn Sampling rate

Xn Trigger mode

J An Talker data set command

Talker data JHn Header ON/OFF of the output data

Wn Delimiter set command

SRQ command AEn SRQ masking command

PRn ON/OFF of REL math operation

Math operation PAn ON/OFF of AVG math operation

command PCn ON/OFF of % math operation

PXn ON/OFF of max/min math

PSn ON/OFF of data storage

AAn Setting the number of averaging

Parameter set AZn Setting full-scale calibration data

A5m,n Setting storage address

Calibration command ZAn Setting calibration mode

Complies with IEEE standard 488-1978 TTL level open collector output (negative logic) TTL level input (negative logic)

GP-IB interface functionSH1, AH1 T5, L4, SR1, RL1, PP0, DC1, DT1, C0, E1

Remote control code (ASCII format)

Data outputData BCD parallel 100 to 104 (Positive logic) Function 4-bit parallel (coded) Decimal point 3-bit parallel (coded) at % math only Range 3 bit parallel (coded) P.COM Positive logic approx 135 µ sec Busy Negative logic, approx. 35 µ sec PolarityOver range

Remote control inputRemote enable Negative logic Function 4-bit code input Range 4-bit code input Sampling rate 2-bit code input RUN/HOLD

Connector plug57-30500 (manufactured by DDK)

TimerThe periodic measurement interval can be set from 00 min. 00 sec. to 99 min.59 sec. using the rotary digital switch on the rear panel.

Accuracy Within 25 sec per 99 min 59 sec.Power supply Supplied from the multimeter Power consumption 10 W or less (including the multimeter)

Withstand voltage ±500 VDC (between the multimeter's COMterminal and output connector)

Dimensions 191W x 65.5H x 65.5L (mm)Weight Approx. 410g Operating temperature 0°C to 40°C, 80% Rh or less;

40°C to 50°C, 60% Rh or lessAccessories Connector plug 57-30500 (1), alignment screw

driver(1) , instruction manual (1 )

SC-304A BCD Output Unit

Remote control Periodic measurement by timer control BCD parallel data output

Specifications

p41-p58 00.9.28 3:10 PM ページ 56

Page 58: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

Output voltage ±99.9 mV or ±999 mV for full scaleConverter accuracy ±0.35% of full scale

(23°C ±5°C , 80% Rh or less)Temperature coefficient ±0.03% of full scale/°C

(0°C to 18°C, 28°C to 50°C )D/A output range 3 digits are output out of 6-digit data. Using the

column select pushbutton switch, the range can beswitched as in the following four steps.4 0 0 0 0 0 ← Multimeter data

n n n ← Lowest 3 digitsn n n ← Lower 3 digits Analog

n n n ← Middle 3 digits output n n n ← Higher 3 digits

Output resistance Approx 90 Ω (±99.9 mV full scale)Approx. 500 Ω (±999 mV full scale)

Offset Offset 500 is available to adjust the D/A converteroutput range.

Power supply Supplied from the multimeter Power consumption 10W or less (including the multimeter)Withstand voltage ±500 VDC

(between the multimeter’s COM terminal and theoutput terminal)

Dimension 191W x 65.5H x 65.5L (mm)Weight Approx. 370 gOperating temperature 0°C to 40°C, 80% Rh or less;

40°C to 50°C, 60% Rh or lessAccessory Instruction manual (1)

57

Specifications

SC-305A D/A Converter Unit SC-306 Battery Unit

Analog output of measured values Self-diagnosis mode

Battery operation Built- in charger

Battery NiCd batteryContinuous operation time Minimum 2 hours after full charge (at normal

temperature) Charging time Approx. 18 hours until fully charged when the

multimeter power switch is off.Battery capacity 6V (1.2 V x 5) , 2000 mAhDimension 191W x 65.5H x 65.5L (mm)Weight Approx. 690gOperating temperature 0°C to 40°C, 80% Rh or less;

40°C to 50°C, 60% Rh or lessAccessory Instruction manual (1)

Specifications

p41-p58 00.9.28 3:10 PM ページ 57

Page 59: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

58

Other options

SC-003High-Voltage Probe30 kV max.

SC-0054-Wire Ohms Test Cable

Soft Case 740

SC-0116SurfaceThermocouple0°C to +500°C for VOAC 7513/7512VOAC 7413/7412

SC-0107Sheath TypeThermocouple-200°C to 800°C forVOAC 7513/7512VOAC 7413/7412

SC-0113Measuring Leads

SC-011Clamp OnCurrent Probe

p41-p58 00.9.28 3:10 PM ページ 58

Page 60: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

59

SC-7207 SC-7206 SC-7205Features 10 mHz to 3 GHz 1 mHz to 2 GHz 1 mHz to 230 MHz

3 GHz, 230 MHz (2) inputs 2 GHz and 230 MHz inputs 230 MHz (2) inputs(A.B.C inputs) (A.C inputs) (A.B inputs)

100 MHz base clock 10 MHz base clock 10 MHz base clock1 ppm/year stability 1 ppm/year stabilty 1 ppm/year stability

10 digits display 10 digits display 10 digits displayMath operation Math operation Math operation

Frequency C 50 MHz to 3 GHz 50 MHz to 2 GHz —Frequency A 10 mHz to 230 MHz 1 mHz to 230 MHz 1 mHz to 230 MHzFrequency Line 45 Hz to 440 Hz — 45 Hz to 440 HzPeriod A 5 ns to 100s (DC) 5 ns to 1000s (DC) 5 ns to 1000s (DC)

5 ns to 0.1s (AC) 5 ns to 0.1s (AC) 5 ns to 0.1s (AC)Duty A 0 to 100% 0 to 100% 0 to 100%Pulse width A 10 ns to 5s (1 ms to 5s gate) 100 ns to 5s (1ms to 5s gate) 100 ns to 5s (1 ms to 5s gate)

10 ns to 100s (Single gate) 100 ns to 1000s (Single gate) 100 ns to 1000s (Single gate)Frequency ratio A/B 1 x 10–10 to 1 x 1010 — 5 x 10-10 to 2 x 1011

Time interval A→B 10 ns to 5s (1 ms to 10s gate) — 100 ns to 5s (1ms to 10s gate)10 ns to 100s (Single) — 100 ns to 100s (Single)

Phase A→B 0 to 360 degree — 0 to 360 degreeTotal A (Accumulation) up to 4,294,967,293 counts up to 4,294,967,293 counts up to 4,294,967,293 counts

Min pulse 2.5 ns 2.5 ns 2.5nsPeak value Vp-A, Vp-B ±2.5 V (1:1), ±50 V (20:1) ±2.5 V (1:1), ±50 V (20:1) ±2.5 V (1:1), ±50 V (20:1)

(A only) (Both A,B)Resolution 10 mV (1:1), 100 mV (20:1) 10 mV (1:1), 100 mV (20:1) 10 mV (1:1), 100 mV (20:1)

(A only) (Both A,B)Bandwidth 150 Hz to 50 MHz 150 Hz to 50 MHz 150 Hz to 50 MHz

A, B input Input RC 1 MΩ approx. //30 pF 1 MΩ approx. //30 pF (A only) 1 MΩ approx. //30 pF (Both A,B)Max input voltage 200 V peak 200 V peak (A only) 200 V peak (Both A,B)

C input Input RC 50 Ω approx. 50 Ω approx. —Max input +30 dBm +30 dBm —

Standard time base 100 MHz 10 MHz 10MHz(Synthesized from 10 MHz)

Temperature coefficient ±2.5 ppm (0 to +40°C) ±2.5 ppm (0 to +40°C) ±2.5 ppm (0 to +40°C)Stability ±1 ppm/year ±1 ppm/year ±1 ppm/year

Output 10 MHz CMOS 10 MHz CMOS 10 MHz CMOSInput 10 MHz ±50 Hz 10 MHz ±50 Hz 10 MHz ±50 HzDisplay 16 digits (10 digits data) 16 digits (10 digits data) 16 digits (10 digits data)Math Scaling (X-a)/b, c/X, X-Xref (X-a)/b, c/X, X-Xref (X-a)/b, c/X, X-Xref

Statistics Max, Min, Ave, Div Max, Min, Ave, Div Max, Min, Ave, DivComparison 2 Threshold values 2 Threshold values 2 Threshold values

GP-IB Installed Installed OptionOptions SC-701 — — GP-IB

SC-702 Comparator out/Ext trigger Comparator out/Ext trigger Comparator out/Ext triggerSC-703 0.02 ppm/day and 0.1 ppm/year 0.02 ppm/day and 0.1 ppm/year 0.02 ppm/day and 0.1 ppm/yearSC-704 0.002 ppm/day and 0.002 ppm/day and 0.002 ppm/day and

0.05 ppm/year 0.05 ppm/year 0.05 ppm/year

UNIVERSAL COUNTER SELECTION GUIDE

p59-p62 00.9.28 3:16 PM ページ 59

Page 61: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

60

Counter SC-7207

C inputInput R 50 Ω approx.Max input voltage +30 dBmSensitivity –20 dBm (100 M to 300 MHz),

–25 dBm (300 M to 1.5 GHz),–20 dBm (1.5 G to 3 GHz)

Coupling ACBurst detect Available

Standard time base 100 MHz (Synthesized from 10 MHz)Temperature coefficient ±2.5 ppm (0 to +40°C)Stability ±1 ppm/year

Output 10 MHz CMOSIntensity modulation output

Input 10 MHz ±50 HzCoupling ACInput R 6.4 kΩ approx.Input voltage 1 Vrms to 5 Vrms

Display 16 digits (10 digits data)Update rate 0.1 to 200s with 0.1s resolution)Masking 1 to 9 digits

MathScaling (X-a)/b, c/X, X-XrefStatistics Max, Min, Ave, DivComparison 2 Threshold values

GP-IB AvailableEnvironmental condition

Operating 0 to +40°C/85%RHStorage –20 to +60°C/90%RH

PowerVoltage AC100/110 to 120/220 to 240 VFrequency 50, 60, 400 HzConsumption 36 VA max. (Included Full Option)

Weight 4 kg max. (Included Full Option)Dimensions 260(W) x 100(H) x 310(L) mmAccessories 2.4 m Power cord (1), Manual (1)Options

SC-702 Comparator out/Ext triggerSC-703 0.02 ppm/day and 0.1 ppm/year 10 MHzSC-704 0.002 ppm/day and 0.05 ppm/year 10 MHz

Note: Only one of the SC-703 and SC-704 models is available.

Frequency C 50 MHz to 3 GHzMeasuring time 1 ms to 10s (5 steps gate), Input B

Frequency A 10 mHz to 230 MHz (DC)10 Hz to 230 MHz (AC)

Measuring time 1 ms to 10s (5 steps gate),Single, Input B

Frequency Line 45 Hz to 440 HzMeasuring time 1 ms to 10s (5 steps gate)

Period A 5 ns to 100s (DC)5 ns to 0.1s (AC)

Measuring time 1 ms to 10s (5 steps gate),Single, Input B

Duty A 0 to 100%Measuring time 1 ms to 10s (5 steps gate),

SinglePulse width A 10 ns to 5s (1 ms to 10s gate)

10 ns to 100s (Single gate)Measuring time 1 ms to 10s (5 steps gate),

SingleFrequency ratio A/B 1 x 10-10 to 1 x 1010

Measuring time 1 ms to 10s (5 steps gate)Time interval A→B 10 ns to 5s (1 ms to 10s gate)

10 ns to 100s (Single)Measuring time 1 ms to 10s (5 steps),

SinglePhase A→B 0 to 360 degree

Measuring time 1 ms to 10s (5 steps gate),Single

Total A (Accumulation) Up to 4,294,967,295 countsMin pulse 2.5 nsMeasuring time Input B, Manual

Peak value Vp-A, Vp-B ±2.5 V (1:1), ±50 V (20:1)Resolution 10 mV (1:1), 100 mV (20:1)Bandwidth 150 Hz to 50 MHz

A, B inputInput RC 1 MΩ approx. //20 pF max.Max input voltage 200 V peakSensitivity 30 mVrms (DC to 230 MHz:

Manual Trigger, ATT 0 dB)Coupling AC/DCAttenuator 0 dB (1:1), 26 dB (20:1)Filter 10 kHz (on/off)Trigger Auto, Manual (±2.5 V)Slope +/–

10 mHz to 3 GHz 3 GHz, 230 MHz (2), 3 inputs (A, B, C inputs) 100 MHz base clock 1 ppm/year stability 10 digits display Math operation GP-IB

The SC-7200 series is a lineup of highly reliable anduser friendly multi-function universal counters. The SC-7207 — the top model of the SC-7200 series— provides full capabilities, including frequency, period,time interval, pulse width, phase, frequency ratio, dutyfactor and event accumulation measurement, with anexcellent time base specification of 1 ppm/year stability.This model is suitable for R&D, QA and production.

Specifications

p59-p62 00.9.28 3:16 PM ページ 60

Page 62: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

61

Frequency C 50 MHz to 2 GHzMeasuring time 1 ms to 10s (5 steps gate)

Frequency A 1 mHz to 230 MHz (DC)10 Hz to 230 MHz (AC)

Measuring time 1 ms to 10s (5 steps gate),Single

Period A 5 ns to 1000s (DC)5 ns to 0.1s (AC)

Measuring time 1 ms to 10s (5 steps gate),Single

Duty A 0 to 100%Measuring time 1 ms to 10s (5 steps gate),

SinglePulse width A 100 ns to 5s (1ms to 10s g gate)

100 ns to 1000s (Single gate)Measuring time 1 ms to 10s (5 steps gate),

SingleTotal A (Accumulation) Up to 4,294,967,295 counts

Min pulse width 2.5 nsMeasuring time Manual

Peak value Vp-A ±2.5 V (1:1), ±50 V (20:1)Resolution 10 mV (1:1), 100 mV (20:1)Bandwidth 150 Hz to 50 MHz

A inputInput RC 1 MΩ approx. //20 pF max.Max input voltage 200 V peakSensitivity 30 mVrms (DC to 230 MHz:

Manual Trigger, ATT 0 dB)Coupling AC/DCAttenuator 0 dB (1:1), 26 dB (20:1)Filter 10 kHz (on/off)Trigger Auto, Manual (±2.5V)Slope +/–

C inputInput R 50 Ω approx.Max input voltage +30 dBmSensitivity –20 dBm (100 M to 300 MHz),

–25 dBm (300 M to 2 GHz)Coupling ACBurst detect Available

Standard time base 10MHzTemperature coefficient ±2.5 ppm (0 to +40°C)Stability ±1 ppm/year

Output 10 MHz CMOSIntensity modulation output

Input 10 MHz ±50 HzCoupling ACInput R 6.4 kΩ approx.Input voltage 1 Vrms to 5 Vrms

Display 16 digits (10 digits data)Update rate 0.1 to 200s with 0.1s resolutionMasking 1 to 9 digits

MathScaling (X-a)/b, c/X, X-XrefStatistics Max, Min, Ave, DivComparison 2 Threshold values

GP-IB AvailableEnvironmental condition

Operating 0 to +40°C/85%RHStorage –20 to +60°/90%RH

PowerVoltage AC100/110 to 120/220 to 240 VFrequency 50, 60, 400 HzConsumption 33 VA max. (Included Full Option)

Weight 4 kg max. (Included Full Option)Dimensions 260(W) x 100(H) x 310(L) mmAccessories 2.4 m Power cord (1), Manual (1)Options

SC-702 Comparator out/Ext triggerSC-703 0.02 ppm/day and 0.1 ppm/year 10 MHzSC-704 0.002 ppm/day and 0.05 ppm/year 10 MHz

Note: Only one of the SC-703 and SC-704 models is available.

Counter SC-7206

1 mHz to 2 GHz 2 GHz, 230 MHz, 2 inputs (A, C inputs) 10 MHz base clock 1 ppm/year stability 10 digits display Math operation GP-IB

The SC-7200 series is a lineup of highly reliable anduser friendly multi-function universal counters. The SC-7206 — the second model of the SC-7200series — provides full capabilities, including frequency,period, time interval, pulse width, phase, frequencyratio, duty factor and event accumulation measurement,with an excellent time base specification of 1 ppm/yearstability. This model is suitable for R&D, QA andproduction.

Specifications

p59-p62 00.9.28 3:17 PM ページ 61

Page 63: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

62

Frequency A 1 mHz to 230 MHz (DC)10 Hz to 230 MHz (AC)

Measuring time 1 ms to 10s (5 steps gate),Single, Input B

Frequency Line 45 Hz to 440 HzMeasuring time 1 ms to 10s (5 steps gate)

Period A 5 ns to 1000s (DC)5 ns to 0.1s (AC)

Measuring time 1 ms to 10s (5 steps gate),Single, Input B

Duty A 0 to 100%Measuring time 1 ms to 10s (5 steps gate),

SinglePulse width A 100 ns to 5s (1 ms to 10s gate)

100 ns to 1000s (Single gate)Measuring time 1 ms to 10s (5 steps gate),

SingleFrequency ratio A/B 5 x 10-10 to 2 x 1011

Measuring time 1 ms to 10s (5 steps gate)Time interval A→B 100 ns to 5s (1ms to 10s gate)

100 ns to 100s (Single)Measuring time 1 ms to 10s (5 steps gate),

SinglePhase A→B 0 to 360 degree

Measuring time 1 ms to 10s (5 steps gate),Single

Total A (Accumulation) Up to 4,294,967,295 countsMin pulse width 2.5n sMeasuring time Manual

Peak value Vp-A, Vp-B ±2.5 V (1:1), ±50 V (20:1)Resolution 10 mV (1:1), 100 mV (20:1)Bandwidth 150 Hz to 50 MHz

A, B inputInput RC 1MΩ approx. //20 pF max.Max input voltage 200 V peakSensitivity 30 mVrms (DC to 230 MHz:

Manual Trigger, ATT 0 dB)Coupling AC/DCAttenuator 0 dB (1:1), 26 dB (20:1)Filter 10 kHz (on/off)Trigger Auto, Manual (±2.5 V)Slope +/–

Standard time base 10 MHzTemperature coefficient ±2.5 ppm (0 to +40°C)Stability ±1 ppm/year

Output 10 MHz CMOSIntensity modulation output

Input 10 MHz ±50HzCoupling ACInput R 6.4 kΩ approx.Input voltage 1 Vrms to 5 Vrms

Display 16 digits (10 digits data)Update rate 0.1 to 200s with 0.1s resokutionMasking 1 to 9 digits

MathScaling (X-a)/b, c/X, X-XrefStatistics Max, Min, Ave, DivComparison 2 Threshold values

Environmental conditionOperating 0 to +40°C/85%RHStorage –20 to +60°C/90%RH

PowerVoltage AC100/110 to 120/220 to 240 VFrequency 50, 60, 400 HzConsumption 31 VA max. (Included Full Option)

Weight 4 kg max. (Included Full Option)Dimensions 260(W) x 100(H) x 310(L) mmAccessories 2.4 m Power cord (1), Manual (1)Options

SC-701 GP-IBSC-702 Comparator out/Ext triggerSC-703 0.02 ppm/day and 0.1 ppm/year 10 MHzSC-704 0.002 ppm/day and 0.05 ppm/year 10 MHz

Note: Only one of the SC-703 and SC-704 models is available.

Counter SC-7205

1 mHz to 230 MHz 230 MHz (2) inputs (A, B inputs) 10 MHz base clock 1 ppm/year stability 10 digits display Math operation GP-IB (option)

The SC-7200 series is a lineup of highly reliable anduser friendly multi-function universal counters. The SC-7205 — the basic model of the SC-7200 series— provides full capabilities, including frequency, period,time interval, pulse width, phase, frequency ratio, dutyfactor and event accumulation measurement, with anexcellent time base specification of 1 ppm/year stability.The model is suitable for R&D, QA and production.

Specifications

p59-p62 00.9.28 3:17 PM ページ 62

Page 64: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

63

Function Function Function Function Function Pulse ScopeModel generator generator generator generator generator generator Calibrator

SG-4112 SG-4102 FG-4101 FG-350 FG-330 PG-230 SC-340(Tentative) (Tentative) Function Function Function Pulse For up to

Features generator genarator genarator genarator 100 MHzDDS Function DDS Scopeand arbitrary generator Calibrator

generator

Output Frequency Sine 10 mHz to 10 mHz to 0.1 Hz to 1 MHz 0.1 Hz to 10 MHz 0.01 Hz to 1 MHz —

15 MHz 15 MHz

Square 10 mHz to 10 mHz to 0.1 Hz to 1 MHz 0.1 Hz to 10 MHz 0.01 Hz to 1 MHz —

15 MHz 15 MHz

Pulse 10 mHz to 10 mHz to — 0.1 Hz to 10 MHz 0.1 Hz to 1 MHz 20 Hz to 50 MHz

100 kHz 100 kHz

Triangle 10 mHz to 10 mHz to 0.1 Hz to 1 MHz 0.1 Hz to 10 MHz 0.01 Hz to 1 MHz —

100 kHz 100 kHz

Ramp 10 mHz to — — — — —

100 kHz

Arbitrary 10 mHz to — — — — —

1.6 MHz

Accuracy 50 ppm 50 ppm ±2% 5% — —

Waveform: Sine Yes Yes Yes Yes Yes —

Square Yes Yes Yes Yes Yes —

Pulse Yes Yes — — — Single/Double

Triangle Yes Yes Yes Yes Yes —

Ramp Yes Yes — — — —

DC Yes Yes — Yes Yes —

Noise Yes — — — — —

Arbitrary Yes — — — — —

Rise/Fall time <100 ns <100 ns <50 ns <20 ns — <5 ns

Number of 2 1 1 1 1 1+TTL

waveform out

Output R: 50 Ω 50 Ω 50 Ω/600 Ω 50 Ω 50 Ω 50 ΩAmplitude Open 20 Vp-p 20 Vp-p 20 Vp-p 20 Vp-p 20 Vp-p 0 to ±10 V

50 Ω 10 Vp-p 10 Vp-p 10 Vp-p 10 Vp-p 10 Vp-p 0 to ±5 V/±10 V

600 Ω — — 10 Vp-p — — —

Duty Square 20–80% 20–80% 15–85% 15–85% 15–85% —

Pulse 1–99% 1–99% — — — —

Triangle 1–99% 1–99% 15–85% 15–85% 15–85% —

Ramp 1–99% 1–99% — — — —

Offset: Open ±10 V ±10 V ±10 V ±10 V Not specified —

50 Ω ±5 V ±5 V ±5 V ±5 V ±5 V —

Modulation AM Yes — Yes — — —

FM Yes — — VCF VCF —

PM Yes — — — — —

PWM Yes — — — — —

FSK Yes — — — — —

PSK Yes — — — — —

MODE Trigger Yes Yes — Yes Yes Yes

Gate Yes Yes — Yes Yes Yes

Sweep Yes — — Yes — —

Other output SYNC Yes (2) Yes Yes Yes Yes Yes (Trig)

Other input Ext. Trigger Yes Yes — Yes Yes Yes

SIGNAL GENERATOR SELECTION GUIDEIwatsu offers wide variety of generators ranging from a synthesized function generator to a scope calibration signalgenerator. A function generator basically outputs square, sine, and triangle waveforms. Some models can alsooutput arbitrary waveforms. Synthesized function generator offers high frequency stability and accuracy.Pulse generators output short transition time pulses and offer a wide range of duration, delay and frequency.

p63-p70 00.9.28 4:18 PM ページ 63

Page 65: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

64

Output waveform: Sine, Square, Pulse, Triangle, Ramp,DC, Noise, Arbitrary waveform

Oscillation frequency range:Sine, Square 10m Hz to 15 MHzPulse, Triangle, Ramp 10m Hz to 100kHzArbitrary waveform 10m Hz to 1.6 MHzAccuracy: 50 ppmResolution 10m Hz(1m Hz) or 9 digits

OutputCH 2CHAmplitude 20 Vp-p or more (output terminal

open), 10 Vp-p or more (50 Ω load)Resolution 3 digits 1mV MinRise time Less than 100 nsOutput R: 50 Ω/±5% (BNC)Offset: ±10 V or more (output terminal open)

±5 V or more (50 Ω load).

Mode CONT, TRIG, GATEDuty

Square 20%~80% (up to 5 MHz)Pulse, Triangle, Ramp 1%~99%

Sweep Linear, LogBurst up to 65536 wavesModulation AM, FM, PM, PWM, FSK, PSK

Frequency range Up to 100kHzArbitrary waveform 16k words x 10 typesIsolation 42V Between signal GND and

chassisInterface RS-232C

GP-IB (option)Power 100, 120, 220,240 V

Specifications

Function Generator SG-4112 (Tentative)

Wide oscillation bandwidth; from 10 mHzto 15 MHz (Sine, Square)

2 simultaneous channel outputs withindependent frequency, waveform andduty setting

Simultaneous display of the frequencyand output voltage with VFD (VacuumFluorescent Display).

High frequency accuracy: 50 ppm Direct Synthesize frequency and

amplitude: Continuously switches thewaveforms

Max. 20 Vp-p (output terminal open) Large offset with a small signal

amplitude wave is available Sweeps with linear or log Various modulation: AM, FM, PM, PWM,

FSK, PSK Arbitrary waveform output Isolated output from chassis

The SG-4112 is a 2-channel output, DDS (Direct DigitalSynthesize) function generator.It features high frequency stability due to the DDS, pluslow distortion and multiple functions, all in a compact,lightweight size.

p63-p70 00.9.28 4:18 PM ページ 64

Page 66: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

65

Specifications

Output waveform: Sine, Square, Pulse, Triangle, Ramp,DC

Oscillation frequency range:Sine, Square 10m Hz to 15 MHzPulse, Triangle, Ramp 10m Hz to 100 kHzAccuracy: 50 ppmResolution 10m Hz or 5 digits

OutputCH 1CHAmplitude 20 Vp-p or more (output terminal

open), 10 Vp-p or more (50 Ω load)Resolution 3 digits 1mV MinRise time Less than 100 nsOutput R: 50 Ω/±5 % (BNC)Offset: ±10 V or more (output terminal open)

±5 V or more (50 Ω load).

Mode CONT, TRIG, GATEDuty

Square 20%~80% (up to 5 MHz)Pulse, Triangle, Ramp 1%~99%

Sweep Linear, LogBurst up to 65536 wavesInterface RS-232C

GP-IB (option)

Power 100, 120, 220,240 V

Wide oscillation bandwidth; from 10 mHzto 15 MHz. (Sine, Square)

Simultaneous display of the frequencyand the output voltage with VFD (VacuumFluorescent Display).

High frequency accuracy: 50 ppm Direct Synthesize frequency and

amplitude: Continuously switches thewaveforms

Max. 20 Vp-p (output terminal open) Large offset with a small signal

amplitude wave is available Sweeps with linear or log 1% – 99% duty controllable (Pulse,

Triangle, Ramp) Up to 65536-waves burst mode

The SG-4102 is DDS (Direct Digital Synthesize)function generator.It features high frequency stability due to the DDS, pluslow distortion and multiple functions, all in a compact,lightweight size.

Function Generator SG-4102 (Tentative)

p63-p70 00.9.28 4:18 PM ページ 65

Page 67: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

66

0.1 Hz to 1 MHz The compact and lightweight SG-4101 FunctionGenerator can be used to generate sine, triangular andsquare waves with frequencies from 0.1 Hz to 1 MHz.The oscillation frequencies can be easily read out fromthe large, bright LED display. The SG-4101 can also beused as a pulse generator as the square wave caneither be symmetrical with a 50:50 duty ratio orasymmetrical with a variable duty ratio.

Oscillation frequency display of 3-1/2digits using large LEDs

Wide oscillation range from 0.1 Hz to 1MHz

Simultaneous 50 Ω and 600 Ω outputs Pulse generation with variable duty ratio Fast 50 ns square wave rise/fall time Max. 20 Vp-p high output voltage (with

terminals open) TTL-level synchronized output Compact, lightweight and portable

Oscillation frequencyFrequency range: 0.1 Hz to 1 MHz, 7 rangesFrequency display: 3-1/2 digit LEDsAccuracy: ±2% or less of set value

(+15 to +35°C) OutputWaveform: Sine wave, triangular wave, square

wave, square wave with variable duty(15:85 or more)

Voltage: 20 Vp-p or more (with output terminalopen), 10 Vp-p or more (50 Ω and600 Ω load)

Attenuator: 3 ranges; 0 dB, 20 dB, 40 dB (50 Ωoutput only) with accuracy ±5%continuously variable for 20 dB andmore

Output R: 50 Ω (BNC), 600 Ω (C typeconnector)

DC offset: Possible to ±10 V or more (withoutput terminal open), ±5 V or more (50 Ω or 600 Ω load)

Sine wave distortion: Less than 1% (10 Hz to 10 kHzrange) (+15 to +35°C)

Triangular wavenonlinearity: Less than 0.5%

(10 Hz to 10 kHz range)Square wavecharacteristics: Rise/fall time less than 50 ns Synchronized outputWaveform: Square waveOutput voltage: +2 V or more (with output terminal

open), +1 V or more (50 Ω load)Output R: 50 Ω (BNC)StabilityFrequency, output voltage: ±0.1% (over 10 min.),

±0.5% (over 24 hrs.)Operating temperature: 0 to 50°CStrorage temperature: –20 to 70°CPower supply Voltage: AC 100/120/220/240 V ±10%, 50 to

400 HzPower consumption: Less than 20 WWeight (approx.): 2.6 kgDimensions (appprox.): 210(W) X 100(H) X 310(L) mmProvided accessories: Power cord (X1), fuse (X2),

accessory bag (X1), operationmanual (X1)

Specifications

Function Generator SG-4101

p63-p70 00.9.28 4:18 PM ページ 66

Page 68: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

67

Function Generator FG-350

0.1 Hz to 10 MHz The FG-350 Frequency Generator provides a widebandwidth (0.1 Hz – 10 MHz), 6 types of waveforms,VCF/VCA facilities and high output (10 Vp-p).

• 6 waveform outputs are selectable —sine, triangle, square (50:50), square(variable), DC, and AM

• Frequency range is continuouslyvariable between 0.1 Hz and 10 MHz

• VCF (Voltage Controlled Frequency)and VCA (Voltage ControlledAmplitude) are provided

• Variable duty ratio up to 85:15 permitsuse as a pulse generator

• Simplified panel design

Frequency range : 0.1 Hz to 10 MHz in 7 ranges andcontinuously variable between ranges

Dial : 0.1 – 10 continuously variableAccuracy : 5% of full scale (at x1 – x100 k range)

10% of full scale (at x1 M range)Signal output

Waveforms : Sine, triangle, square (50:50), square(variable), DC, AM

Variable duty ratio : 50:50 to 85:15 continuously variableOutput R : 50 Ω ±5%Amplitude : 10 Vp-p (50 Ω load), 20 Vp-p (output

terminal open)Attenuator : Three pushbutton selection

0 dB, 20 dB, 40 dB and continuouslyvariable between ranges

DC offset : More than ±10 V (output terminal open)More than ±5 V (50 Ω load)

Sine-wave distortion : Less than 0.5% (at 10 Hz – 1 kHz)Triangle wave non-linearity : Less then 1% (at 10 Hz – 1 kHz)

Square waveRise and Fall time : Less than 20 ns

Sync. outputWaveform : Square waveOutput voltage : More than +2 V (open circuit)

More than +1 V (50 Ω load)Ext. gate trigger

Input R : Approx. 10 kΩInput sensitivity : Min. 2 Vp-p (Sine)

Min. +1 V (Pulse)Pulse Width: More than 50 ns

Input frequency : DC – 5 MHzOSC mode

CONT : Continuous oscillatingGATE : Signal appears continuously while a signal

is applied to GATE/TRIG IN.TRIG : Single oscillatingMAN : Manual operation of GATE, TRIG and

TRIG SWEEP

Sweep modeCONT SWEEP : Continuous sweepTRIG SWEEP : Single sweepSweep width : Max. 100: 1 (in 1 range)Sweep Time : 1 ms – 10s in 4 ranges and continuously

variable with FINE tuningSweep out

Sawtooth out : 0 – 10 V peak (output terminal open)0 – 5 V peak (50 Ω load)

Square out : More than +2 V (output terminal open)More than +1 V (50 Ω load)

VCF (Voltage controlled frequency)Input R : Approx. 100 kΩControllable frequencyRange : All ranges possibleMax. input voltage : +10 VInput voltage : 10 V. [Dial Scale + Input Voltage (V)]

0.01 V (at Dial "ON")OSC frequency is controlled by VCF inputvoltage (at Dial "OFF").Frequency Variable: up to 1,000 : 1

VCA (Voltage controlled amplitude)Input R : Approx. 10 kΩControllable frequencyRange : All ranges possibleOutput voltage : Max. 20 Vp-p (open circuit)

(at ±5 V input)Input frequency : DC – 1 MHz, –3 dB

Power supply : AC 100/117/200/217/234 V ±10%,50 – 400 Hz, less than 50 Watts

Dimensions and weight : Approx. 210(W) x 100(H) x 410(L) mmAccessories : Fuse . . . . . . 2

Accessory bag . . 1Instruction manual . 1

Specifications

p63-p70 00.9.28 4:18 PM ページ 67

Page 69: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

68

Specifications

0.01 Hz to 1 MHz

• 5 waveform outputs are selectable —sine, triangle, square, pulse and DC

• Simultaneous 50 Ω and 600 Ω outputs• Frequency range from 0.01 Hz to 1 MHz• VCF (Voltage Controlled Frequency) • Pulse generation with up to 85:15

variable duty ratio

Frequency range : 0.01 Hz – 1 MHz in 7 rangesContinuously variable between ranges

OutputWaveform : Sine, triangle, square, pulse, DCVariable duty ratio : 50:50 to 85:15Amplitude : 10 Vp-p min. (50 Ω or 600 Ω load)

20 Vp-p (open circuit)Attenuator : 0 dB, 20 dB, 40 dBOutput R : 50 Ω (BNC terminal)

600 ΩSine-wave distortion : Less than:

0.5% at x0.1, x1, x10, x100, x1 k ranges3% at x10 k range

DC offset : ±5 V min. (50 Ω or 600 Ω load)Frequency modulation

VCF : x1000 max. by (±) external signalx100 max. by only (+) external signal

Sync. outputWaveform : Square waveAmplitude : 2.7 Vp-p min. (50 Ω load)Impedance : 50 Ω (BNC terminal)

ModesCONTINUOUS : Output frequency is selected by a front

panel control knob, or the some ofexternal control voltage (VCF IN) and thefront panel control knob.

TRIGGER : One cycle of waveform is output at 50 Ω OUT terminal when pulse is appliedto GATE/TRIG IN, or when a manualswitch is pushed.

GATE : Gate signal appears continuously while asignal is applied to GATE/TRIG IN.

GATE/TRIG INInput voltage : 500 mV – 30 VInput R : 22 kΩ (BNC)

Power supply : AC 100/117/217/234 V ±10%Approx. 15 W

Dimensions and weight : Approx. 210 (W) x 100 (H) x 300 (L) mm

Approx. 3 kgAccessories : Fuse . . . . . . . . . . 2

Accessory bag . . . . . . 1Instruction manual . . . . 1

Function Generator FG-330

p63-p70 00.9.28 4:18 PM ページ 68

Page 70: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

69

• Wide range of repetition ratesInternal: 20 Hz — 50 MHzExternal: DC — 50 MHz

• Wide range of output voltage0 V — ±10 V (with 50 Ω load)

• Fast rise and fall time of 5 ns• TTL-level output terminal• Compact and lightweight design

m Output waveform at a repetition rate of50 MHz

Sweep rate: 20 ns/divVertical deflection factor: 2 V/divPolarty: Positive

m Output waveform at low frequencySweep rate: 10 ms/divVertical deflection factor: 2 V/divPolarity: Positive

m Leading edge of positive polarity pulseSweep rate: 2 ns/divVertical deflection factor: 2 V/div

m Trailing edge of negative polarity pulseSweep rate: 2 ns/divVertical deflection factor: 2 V/div

Output pulseRepetition rate : 20 Hz – 50 MHzPulse delay : 10 ns – 50 msPulse width : 10 ns – 50 msAmplitude : At HIGH internal impedance

0V – ±10 V (50 Ω load)At 50 V internal impedance0V – ±5 V (50 Ω load)

Rise & fall time : 5 ns or fasterWaveform distortion : 5% or lessDuty factor : 50% or moreOutput impedance : 50 ΩSingle pulse : AvailableDouble pulse : Available

External trigger inputPulse input : +1 V – +5 V (positive going)Pulse width : 10 ns or widerSine-wave input : 2 Vp-p – 5 Vp-pFrequency : DC – 50 MHzInput impedance : 50 Ω ±5%Coupling : DC

Trigger outputAmplitude : At open load +2 V

At 50 V load +1 VWaveform : Square waveOutput impedance : 50 Ω ±5%Coupling : DC

TTL output : TTL level (at open load)FAN OUT 1

Power requirements : AC 100/117/217 V ±10%50/60 Hz, 30 W approx.

Net weight : 4.5 kg approx.Dimensions : Approx. 210(W) x 100(H) x 350(L) mm Standard Accessories : Fuse . . . . . . 2

Accessory bag . . 1Instruction manual . 1

DC — 50 MHz, 0 V — ±10 V

Pulse Generator PG-230

Specifications

p63-p70 00.9.28 4:18 PM ページ 69

Page 71: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

70

Oscilloscope Calibrator SC-340

Specifications

The SC-340 is a signal generator for checking andcalibrating the deflection factor, sweep rate, pulseresponse, and triggering of oscilloscopes withbandwidths up to 100 MHz.

The SC-340 allows users to adjust theiroscilloscope for more efficient usage. Not only that,but the SC-340 also allows major adjustments to beperformed, making measurements more reliable.

It serves also as a general purpose signalgenerator.

Adjustment items are as follows:1. Deflection factor and attenuator compensation

(maximum output voltage: 100 V, square-wave: 1kHz)

2. Sweep rate (high accuracy by using a highlystable crystal oscillator)

3. Pulse response (square wave with low distortion)4. Leading edge of square wave (rise time: 300 ps

or less)5. Trigger checking

Voltage caribrator (calibrates deflection factor)Output voltage : 0.12 mV – 60 V, 18 steps (1.2-3-6)

0.2 mV – 100 V, 18 steps (1-2-5)accuracy; within ±0.5% (into 1 MΩ load)

Output waveform : Square wavePolarity : Positive going from 0 V base lineRise time : 5 µs or lessWaveform distortion : ±0.5% or lessOutput R : 50 Ω (0.12 mV – 0.2 V range)

Time calibrator (calibrates sweep rate)1) Pulse train : 0.1 µs – 2s, 23 steps (1-2-5)

accuracy; within ±0.05%Output voltage : 0.1 V or more (into 50 Ω)Output waveform : PulsePolarity : Positive going

2) HF : 10 ns, 20 ns accuracy; within ±0.05%

Output voltage : 0.2 V or more (into 50 Ω)Output waveform : Sine wave (10 ns), square wave (20 ns)

Sine-wave generator (checks triggering)Frequency : Line frequency; 50/60 Hz or

1 kHz ±20%Waveform calibrator (calibrates pulse response)

Output waveform : Square waveRise time : 5 ns or lessOutput frequency : 0.5 Hz – 1 MHz, 20 steps (1-2-5)Output voltage : Approx. 50 mV (50 Ω load) min.

High-speed rise calibrator (calibrates rise of square wave)Output waveform : Oscillation of tunnel diodeRepetitive frequency : 10 kHz – 200 kHzRise time : 300 ps or lessWaveform distortion : 3% or less

(measured with 100 MHz oscilloscope)Temperature range forguaranteed accuracy : +10°C – +35°COperating temperaturerange : 0°C – +50°CPower supply : AC 100/117/217/234 V ±10%,

50/60 Hz, approx. 15 WWeight : Approx. 3.5 kgDimensions : Approx. 210(W) X 100(H) X 350(L)mm

0.12 mV – 60 V0.2 mV – 100 V0.1 ms – 2 s0.5 Hz – 1 MHz

p63-p70 00.9.28 4:18 PM ページ 70

Page 72: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

77

ITF-205Laser Displacement MeasurementTraining KitLearning how to perform displacement measurementusing a laser diode and photodetector (i.e. a digital linesensor) is made possible with the ITF-205.

The main features of this kit are:1. Well-defined panel layout and test terminals2. LED indicators for the photodetector that show the current

position of the moving target3. Visible laser beam allows easy identification of the beam

path4. Target positioning device for moving the target back and

forth slightly

ITF-204Frequency Modulator/DemodulatorTraining KitThis kit demonstrates the basic operation of an FMreceiver as well as the principles of frequencymodulation and demodulation using a radio detector.

Learning items:1. Frequency modulation using a varactor diode2. Demodulation using a ratio detector

A built-in microphone and speaker make the ITF-204ready to use, while an external microphone jack offersextra flexibility. In addition, test points at each circuitblock allow students to easily check how each oneworks. This training kit can also be installed in theITF-015 rack mount.

Meter panelSampling frequency Approx. 50 times/sec. (approx. 20 ms)Laser (semiconductor laser)

Wavelength 670 nmOutput 1 mW (class 2)Spot Approx. 0.5 to 2 mm in diameter

Displacement display 4-digit decimal displayOutput

Start signal TTL level, load signalVideo signal Approx. 2 Vp-p Analog data Approx. 10 mV/10 µm, zero displacement

range approx. ±10 VSensor

ProjectorElement Visible light laser diode (semiconductor laser)Output 2 mW or less

Receiving light elementElement 512-bit digital line sensorAngle 33° triangulation measuring systemMeasuring range ±5 mm (45 mm center)

Resolution Approx. 20 µmPositioning stage

Stroke Approx. ±10 mmDisplay 3-1/2 digit LED display for

measurement results, LED indicatorsfor line sensor

Power supply AC 100/117/200/217/234 V, 50/60 Hz,approx. 15 W

Size and weight 350 (W) X 83 (H) X 250 (L) mm, 6 kgOperating temperature 0° to 40°C, 85% RH

Input amplifier sectionExternal microphone 500 kΩ input impedanceGain 50 dB ±3 dBLoad impedance allowed 50 kΩ or moreOutput maximum voltage 1 Vp-p or moreDistortion 1% or less at 1 kHz

Modulator sectionModulation Varactor diodeDemodulation Ratio detectorCenter frequency 10.7 MHz ±50 kHzMaximum voltage 110 dBµ (0.3 Vp-p) or more

Receiver sectionAntenna matched impedance 75 Ω unbalanced (external antenna

connection available)Receiving frequency 75 MHz to 110 MHzIF frequency 10.7 MHz Practical sensitivity Within 10 dBFrequency characteristic 50 Hz to 15 kHz (±3 dB, 0.2 W

output)Output impedance 8 Ω (4 to 16 Ω load available)Maximum output Approx. 0.5 W

Power supply DC 15 V ±1 V/150 mA DC (external power supply required)

Size and weight 350 (W) X 83 (H) X 250 (L) mm,approx. 3 kg

Operating temperature 0° to 40°C, 85% RH

Training Kits ITF-204/205

Specifications

Specifications

p71-p77 00.9.28 4:25 PM ページ 77

Page 73: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

76

ITF-202Operational Amplifier Training KitThis kit demonstrates how an operational amplifierworks, how its specifications can be evaluated, as wellas the applications it can be used for. Eventually, this kitmakes it possible learn how to design an analog circuitusing an operational amplifier.

External resistors and capacitors can beadded to increase the design flexibility.

The training kit consists of the following sixsections:1. Power supply section2. Amplifier section3. Active filter section4. Wien bridge oscillator section5. Differentiator/Integrator section6. Test power source section

Amplifier sectionOscillator section

Oscillation Wien bridge oscillatorFrequency 1 kHz to 50 kHzAmplitude ±6 Vp-pLimiter Diode limiter

Active filter sectionCircuit Voltage source typeAttenuation 2nd order (-12 dB/Oct)Frequency range 1 kHz to 10 kHz

Integrator sectionFrequency 16 Hz or more

Differentiator sectionFrequency 16 kHz or less

Test power source sectionOutput voltage 1.0 V (0.990 V to 1.010 V)

–3 V to 3 V (3.030 V to 2.970 V)Output current 2 mA max.

Power supply AC 100/117/200/217/234 V,50/60 Hz, approx. 3 W

Size and weight 350 (W) X 250 (L) X 83 (D)mm,4.2kg

Operating temperature 0° to 40°C, 85% RH

ITF-203AD/DA Converter Training KitThe ITF-203 shows how one of today's most importantcircuit techniques — analog to digital conversion anddigital to analog conversion — works.

Learning items:1. Successive-approximation A/D conversion2. D/A conversion3. What vertical resolution is and how it works4. What a sampling clock is and how it works5. Data communication via a GPIB or RS-232C interface

using a personal computer

A built-in microphone and speaker offer a simple audiodigitizer circuit. Featuring test points at each circuitblock allows students to easily check how each oneworks.

DA output –5.12 V to +5.08 V or audio outputMemory length 20 kwordsPower supply AC 100/117/200/217/234 V, 50/60 Hz,

approx. 13 WSize and weight 350 (W) X 83 (H) X 250 (L) mm, 4.5 kgOperating temperature 0° to 40°C, 85% RH

AD input ±5.12 V, 0 to 10.24 V, or audio sourceInput frequency DC to 20 kHz or moreAD resolution 8 bits or 4 bitsSampling rate INT: 5 µs to 0.5 s (1-2-5 steps)

EXT: External clock up to 5 µsDA resolution 8 bits

Training Kits ITF-202/203

Specifications

Specifications

p71-p77 00.9.28 4:25 PM ページ 76

Page 74: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

75

ITF-07Arithmetic Circuit Training KitThe ITF-07 kit incorporates the basic circuits of acalculator on its panel to provide visual training in fourarithmetic operations.

Characteristics: The circuit elements necessary for arithmetic calculation

are indicated graphically on the panel for easyunderstanding.

While inputs are in decimal and calculations are in binary,results can be given in decimal or binary.

Register contents are indicated as [0] or [1] on the LEDdigit indicator.

Learning items: Adding calculators Subtracting calculators Multiplying calculators Dividing calculators

Calculating system Binary calculating system by manualcontrol

Addition 1-digit addition (0+0=0 ~ 9+9=18),Accumulation: 19 max.

Subtraction 1-digit subtraction,Accumulation: –15 max.

Multiplication 1-digit multiplication (0x0=0 ~ 9x9=81)Division 1-digit division (0÷1=0 ~ 9÷1=9)Power supply AC 100/110/117/200/220/234 V,

50/60 Hz, 10 W Size and weight 450 (W) X 330 (H) X 80 (L) mm, 5.8 kgOperating temperature 0° to 50°C, 90% RH

ITF-201Optical Transmission Training KitThe ITF-201T functions as a transmitter and the ITF-201R functions as a receiver, with an optical fiberconnecting the two together. This kit is a suitable aid fortraining in:

1. Analog data transmission using optical modulation2. Digital data transmission using A/D and D/A converters3. Electric/optical and optical/electric converter devices

ITF-201R ReceiverITF-201T TransmitterInput

Internal signal 1 Hz square wave, two kinds ofartificial IC music

Microphone Internal or external (optional)External input 0.1 V to 10 V

Transmission mode Analog, digitalA/D converter

Mode of operation Successive-approximation converterResolution 8 bitsInput voltage –10.24 V to +10.16 VSampling period 0.5 ms to 10 ms in 5 steps

OutputMode of operation Optical modulation using LED diodeWavelength 660 nmBias Analog, digital, variable

Data transmissionMode of operation RS-232C, NRZ, 19,200 baud ratePower supply AC 100/117/200/217/234 V, 50/60 Hz,

approx. 12 WSize and weight 350 (W) X 150 (H) X 83 (D) mm, 4 kg

Operating temperature 0° to 40°C, 85% RH

InputInput signal Optical signal (PIN photo diode)Bias Analog, digital, variable

Serial D/A converterResolution 8 bitsD/A output –10.24 V to +10.16 V

Output SpeakerPower supply AC 100/117/200/217/230 V, 50/60 Hz,

approx. 10 WSize and weight 350 (W) X 150 (H) X 83 (D) mm, 4 kgOperating temperature 0° to 40°C, 85% RH

Training Kits ITF-07/201

Specifications

Specifications

p71-p77 00.9.28 4:25 PM ページ 75

Page 75: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

74

ITF-05Semiconductor Training KitThe ITF-05 kit is used to master two-terminal andthree-terminal semiconductors, by focusing on theoperation and characteristics of various semiconductordevices.

Characteristics: This is a general-use training kit that allows various two-

terminal and three-terminal semiconductor devices to bemeasured.

A variable source (current and voltage) controlling thecontrol electrodes (transistor gate, FET gate, SCR gate,etc.) of three-terminal semiconductors is integrated,reducing the need for external sources when performingthe same kind of training in a single session.

The self-contained voltage source allows mastery of two-terminal power semiconductors.

AC measurement of the h parameter is possible intransistor training.

Protection from short-circuits, miswiring, etc. is built into theunit.

Learning items: Characteristic (voltage and current) measurement of two-

terminal devices (measurements: diode, zener diode,selenium rectifier, varistor, thyristor, etc.)

Characteristic (voltage, current and various parameters)measurement of three-terminal devices.

Transistors (static characteristic and h parameter (ACoverlapping))

FET (static characteristic, amplitude and impedance) SCR (static characteristic)

ITF-06Counter Circuit Training KitBy studying circuits on the ITF-06 kit’s panel and thencombining them, the basic operation of an electroniccounter can be understood.

Characteristics: Each circuit element is indicated graphically on the panel

for easy understanding. Each circuit element has input/output terminals, allowing for

easy circuit configuration for each function. Training for 5 functions can be performed (frequency

measurement, period measurement, time intervalmeasurement, frequency ratio measurement, totalizingmeasurement)

Learning items: Frequency measurements Period measurements Time interval measurements Frequency ratio measurements Totalizing measurements

Control power source Voltage: 0 V to +10 V (50 mA max.),0 V to -10 V (0.1 mA max.)Current: 0.01 to 10 mA (3 steps)

Power supply AC 100/117/220 V, 50/60 Hz, 5 W(typical)

Size and weight 340 (W) X 240 (H) X 80 (L) mm, 3 kgOperating temperature 0° to 50°C, 90% RH

Frequency measurement 1 MHz max.Counting time 1 ms, 10 ms, 0.1 s, 1 s

Period measurement 1 ms to 10 sTime base 1 ms, 10 msNumber of periods 1, 10, 100

Time interval measurement 1 ms to 1000 sTime base 1 ms, 10 ms, 0.1 s, 1 s

Frequency ratio measurement f1: 1 MHz max., f2: 1 MHz max., Magnification: 1X, 10X, 100X

Totalizing Capacity: 999, Resolution: 1 µsInput sensitivity 0.1 VrmsDisplay of digits 3 digitsPower supply AC 100/110/117/200/220/234 V,

50/60 Hz, 20 WSize and weight 450 (W) X 330 (H) X 80 (L) mm,

5.5 kgOperating temperature 0° to 50°C, 90% RH

Training Kits ITF-05/06

Specifications

Specifications

p71-p77 00.9.28 4:25 PM ページ 74

Page 76: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

73

ITF-02Logic Circuit Training KitThe ITF-02 is provided with circuit elements, signalsources and an indicator on its panel to promote visuallearning, from the foundation to practical applications oflogic circuits.

Characteristics: Each circuit element is indicated graphically on the panel

for easy understanding. The level of input/output is indicated as [0] or [1] on the

LED on the panel. Each circuit element has input/output terminals, allowing for

numerous combinations of connections between circuitelements.

Many circuit elements are provided (45 gates, 10 flip flops)to meet all requirements.

Because signal sources are built-in, most training exercisescan be performed without an external generator.

Learning items: Basic operation of AND, OR, NOT, NAND, NOR and

Exclusive OR Assembly and operation of half adders and full adders Assembly and operation of encoders and decoders Basic operation of R-S and J-K flip flops Basic operation of shift registers and other applications

ITF-03Pulse Circuit Training KitThe ITF-03 is provided with circuit elements and signalsources on its panel to promote visual learning, fromthe foundation to practical applications of pulse circuits.

Characteristics: Each circuit element is indicated graphically on the panel

for easy understanding. Constants can be designed and connected by students,

allowing them to compare standard operation withoperation changed by the new constant, facilitating easierunderstanding of applications.

Each circuit element has input/output terminals, allowing fornumerous combinations of connections between circuitelements.

Many circuit elements are provided (13 kinds) to meet allrequirements.

Because signal sources are built-in, most training exercisescan be performed without an external generator.

Learning items: Differentiation circuits and integration circuits Clip circuits and clamp circuits Logic circuits (AND, OR and NOT) Miller circuits and bootstrap circuits Multi-vibrators (mono-stable, astable, bistable and Schmitt

trigger)

Circuit elements AND, OR, NOT, NAND, NOR,Exclusive OR, R-S FF, J-K, half-shiftregister, [0] and [1] LED indicator (10digits)

Signal sources 1 kHz square wave, about 5 Vp-p; 10Hz square wave, about 5 Vp-p; resetpulse 0 V to +5 V; one-shot clockpulse, about 4 Vp-p, 0.3 µs

Power supply AC 100/110/117/200/220/234 V, 50/60 Hz, 10 W

Size and weight 570 (W) X 400 (H) X 80 (L) mm, 7.5 kgOperating temperature 0° to 50°C, 90% RH

Circuit elements 13 kinds (differentiation, integration,clamp, clip, AND, OR, NOT, Miller,bootstrap, mono-stable multi-vibrator,astable multi-vibrator, bistable multi-vibrator, Schmitt trigger)

Signal sources 1 kHz square wave, about 10 Vp-p; 1kHz sine wave, about 10 Vp-p; 100Hz square wave, about 10 Vp-p

Power supply AC 100/110/117/200/220/234 V,50/60 Hz, 20 W or less

Size and weight 570 (W) X 400 (H) X 80 (L) mm, 7 kgOperating temperature 0° to 50°C, 90% RH

Training Kits ITF-02/03

Specifications

Specifications

p71-p77 00.9.28 4:25 PM ページ 73

Page 77: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

72

ITF-01Electronic Circuit Training KitThe ITF-01 is composed of four units with rack mountthat offer a practical way to study a various circuits thatform the basis of a larger electronic circuit. Since thecombination of the ITF-012, 013 and 014 composes aradio receiver, students will gain an understanding ofthe basic circuits as well as how they interact overall.

Characteristics: The four training kits can be assembled in the ITF-015 rack mount

to form a radio receiver, on which training exercises can beperformed.

Since an amplifier circuit is the basis of most other electroniccircuits, by studying it students will gain fundamental knowledge ofcircuits in general.

The standard basic operation of each circuit is only possible whenall are connected together, however, constants designed byinstructors can also be attached, expanding the possibilities forstudent learning.

The ITF-014 training kit also operates as the power source for allfour kits, making an external power source unnecessary.

ITF-011

ITF-012

ITF-013

ITF-014

ITF-015 Learning items:1. ITF-011 Oscillator and Modulator Training Kit Collector tuning (bias, frequency and oscillation) CR-type phase shift oscillators Collector modulation circuits

Collector tuning type oscillation circuitOscillating frequency 100 kHz ±5%, 5 Vp-p or more

CR-phase-shifting type oscillation circuitOscillation frequency 1 kHz ±20%, 5 Vp-p or more,

external setting possibleCollector modulation circuit

Carrier wave frequency 100 kHzSignal wave frequency Approx. 1 kHz

2. ITF-012 AM Receiver Circuit Training Kit IF tuning characteristics AGC and non-AGC bias characteristics Detection characteristics Receiver circuits and frequency converters

Antenna Built-in bar antenna, external antennaterminal

Receiving frequency 520 kHz to 1650 kHz, adjustableIF adjustment 455 ±10 kHz or moreAGC selection AGC on/off switchable

3. ITF-013 Audio Amplifier Circuit Training Kit Bias setting, amplitude, frequency characteristics, phase

characteristics and wide band amplification (feedback, peakingand low-frequency boosts)

2-stage amplifier circuits Power amplifier circuits (bias, power, efficiency and distortion)

4. ITF-014 Rectifier Circuit Training Kit Half-wave and full-wave rectifier circuits) Smoothing circuits (C, LC and π)

Transformer secondary winding 18 Vrms, 0.3 Arms15 V stabilizing power source +15 V ±5% or more, 0.15 A

(current limiter approx. 0.25 A)Power supply AC 100/220 V, 50/60 Hz, 10 W

Training Kits ITF-01

Specifications

Specifications

Specifications

p71-p77 00.9.28 4:25 PM ページ 72

Page 78: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

71

ITF SERIESIWATSU Trainer Family

ITF Series (IWATSU Trainer Family)ITF-201 Optical Transmission Training KitITF-202 Operational Amplifier Training KitITF-203 AD/DA Converter Training KitITF-204 Frequency Modulator/Demodulator Training KitITF-205 Laser Displacement Measurement Training KitITF-01 Electronic Circuit Training KitITF-02 Logic Circuit Training KitITF-03 Pulse Circuit Training KitITF-05 Semiconductor Training KitITF-06 Counter Circuit Training KitITF-07 Arithmetic Circuit Training Kit

Training EquipmentThe fast-evolving and ever-changing nature of theelectronics industry has created a need for easy-to-usetraining kits that can effectively increase understandingof semiconductors, optical transmission, frequency anddisplacement gauges. Especially designed for use inapplications such as integrated circuitry, the teachingmodels in IWATSU’s ITF series allow operation to beseen and understood visually, dramatically enhancingstudent comprehension.

Training modules are designed so that theory and practicecomplement one another. In addition, practical exercises andapplications are provided.

Each product is designed so thatit can be installed in a standardinstrument cabinet for easycontrol and storage.

The provided manuals can be used in a variety of ways. Forexample, an optimum training curriculum can be created to suit yourneeds.

Curriculum

Instruction manual

Common Features

Stacking OK

p71-p77 00.9.28 4:25 PM ページ 71

Page 79: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

78

1. OverviewThe key measurement method used by oscilloscopes is probing. When measuring a circuit, a small amount of energy is taken out throughthe probe. The less energy taken out, the less effect on the circuit. It is necessary to consider the influence of the probe on the circuit beingtested (Loading effect). Even if you have a high bandwidth scope, improper probing can result in low bandwidth measurement and low fidelity.

2. Classification of ProbesProbes are categorized as passive probes, simple resistance dividers, and active probes, which require an external power supply (such asFET probes). These categories are further divided into voltage probes and current probes.

Probe Passive Voltage 1:1 Probe 10:1 Probe High voltage Wide bandwidth

Current

Active Voltage FET probeDifferential, etc.

Current

3. Reasons For Using ProbesWhat problems will occur if a wire is connected directly from the input terminal of the oscilloscope to the circuit being tested?1) Easily affected by noise.2) The frequency bandwidth is reduced.3) Loading effect is greater.

Problem 1): Can be mitigated by the use of coaxial cable or shielded wire. However, this solution does not work for problems 2) and 3).

Problem 2): When a wire is directly connected, the frequency bandwidth is limited by the inductance and stray capacitance of the wire. The use of a 10:1 probe, however, can eliminate this influence.

Problem 3): If the wire is connected directly when the oscilloscope input is viewed from the side of the circuit being measured, thecapacitance and inductance constitute a load as is the case in problem 2). In this case, there is still a high load even if a shielded wire is used for connection.

Then, what will happen when a 10:1 probe is used?Let's compare the 10:1 probe and shielded wire.Probe: 1.5 m 10:1 probe with an input capacitance of 15 pF

Shielded wire: 1.5 m total capacitance 150 pF(unit capacitance 100 pF/m)Oscilloscope : Input capacitance of 30 pF

Conclusion: Loading effect of the capacitance will be reduced from 180 pF (150+30) to 15 pF.

But the amplitude will be attenuated to 1/10.

4. How to Use Probes4-1 Probe compensationBefore starting the probing, it is necessary to compensate the probe. Probe compensation means compensation for the probe frequency characteristics. Fig. 1Adjust C3 so that the following relationship can be obtained:R1 x C1 = R2 x (Cc + C2 + C3) : Cc = Cable capacitanceIf measurement is performed with no probe compensation, an extreme error in signal amplitude may occur around 10 kHz.

4-2 Input capacitanceInput capacitance can be reduced to 15 pF by using a probe as described in Section 3. This section looks at the influence of the inputcapacitance. (Loading effect).

Fig. 1

Probing

p78-83 00.9.28 4:39 PM ページ 78

Page 80: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

5. Special purpose probes

5-1 FET ProbeThe prime feature of the FET probe is that it has a low input capacitance of approx. 2 pF.

5-2 Wide bandwidth probeThis probe is most suitable for measuring a 50 Ω signal system, etc.Although the input resistance and capacitance are lower than other passive probes (500 Ω and 0.7 pF for 10:1 and 5 kΩ and 0.6 pF for100:1), the values are high enough for a 50-ohm system.At the same time, these probes maintain a high impedance of 100 MHz or more.

5-2-1 Comparison of probe specifications and input impedanceThe input impedance and frequency characteristics of these three types of probes and 1:1 probe are as shown in Fig. 8. Input impedance ofthe 10:1 probe is lower than that of the FET probe when the frequency exceeds 10 kHz. The input impedance of 10:1 and 1:1 probes is lower than that of the wide bandwidth probe within the range of 10 MHz to 1 GHz.

5-5 Current ProbeCommon probes pick up voltages, but a current probe is used to directly measure currents by clamping a wire without cutting.

Insertion impedanceCurrent probes can affect a circuit with insertion impedance.The value of insertion impedance depends on the individual model, but as a rule of thumb, the value is normally less than 0.1 ohm.

Fig. 9 shows the measurement of the ripple current that flows into a smoothing capacitor in a power circuit.

Isolation voltageThe isolation voltage of a current regulator is 300 V. Be careful when measuring a switching regulator circuit (Fig. 10).

Point 1 is best, point x is worst. (1 > 2 > 3 > x)Point 2 is slightly affected by voltage interference.Point 3 is equal to the rating limit (300 V).Point x is over the rating limit, and is greatly affected by voltage interference.

80

Fig. 9

Fig. 10

Fig. 8

AC

+300 V

SW Reg

(Ω)

Frequency (Hz)

IMP

ED

AN

CE

10 M

1 M

10 100 1 k 10 k 100 k 1 M 10 M 100 M 1 G

1 k

100

10

0

3

x

2

1

Probe impedance vs Frequency

p78-83 00.9.28 4:39 PM ページ 80

Page 81: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

82

SS-0012SS-0016

SS-078R

SS-101R

SS-0062

SS-082R

SFP-4ASFP-5A

SS-0012RSS-017R

HZ-501AHZ-502A

SS-084R

SS-0130RSS-0131R

SS-0110SS-0120SS-0121

p78-83 00.9.28 4:39 PM ページ 82

Page 82: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

84

MT-45• For DS-9121/DS-9122/TS-8422• Two 3-pin power supply sockets• Tray is adjustable in five steps of -10°,

-20°, +10°, and +20° with one-touchoperation of the lever.

Carrying capacity: 50 kg (30 kg for tray, 20 kgfor lower tray)Dimensions: Approx. 468 (W) x 620 (L) mmWeight: Approx. 32 kg

MT-555A• For mid-sized models• Drawer provided under the lower tray

for accessories• Casters with stoppers

Carrying capacity: 40 kg (27 kg for tray, 13 kgfor lower tray)Dimensions: Approx. 500(W) x 500(L) mmWeight: Approx. 17 kg

SCOPE WAGONS

SK-2101A• Designed for use with lightweight

oscilloscopes• Main tray is adjustable in five steps for

easy visibility; 10° down, and 10, 20and 30˚ up

Carrying capacity: Within 17 kg Main tray dimensions: Approx. 330 (W) x 470(L) mm Weight: 13.5 kg approx.

TerminationsSpecifications

BP-50M1 BP-75M1 BB-50M1

Frequency Range DC – 3 GHz DC – 1 GHz

Impedance 50 Ω 75 Ω 50 Ω

Max. VSWR 1.37 (– 1 GHz)1.25 (– 1 GHz)

1.1 (– 500 MHz)1.25 (– 1 GHz)

Power Rating Ave.: 0.5 W Peak: 500 W

Connectors BNC typeplug

BNC typeplug

BNC feed-through type

Peak power; measured at pulse width 5 ms max.

1.1 (– 1 GHz) 1.2 (– 3 GHz)

B-50D3 B-50D4

Impedance 50 ΩFrequency DC – 3 GHz

Nominal Insertion Loss 6 dB 9.5 dB

Max. VSWR

Power Rating Ave.: 2 WPeak: 2 kW*

Ave.: 1 WPeak: 1 kW*

DividersSpecifications

Connectors BNC type

Terminals 3 4

Peak power; measured at pulse width 5 ms max.

1.2

Conversion PadSpecifications

B-5P7J1

Connectors

Frequency Range DC – 2 GHz

BNC feedthrough type

Impedance 50 Ω (BNC-P) – 75 Ω (BNC-J)

VSWR 50 Ω terminal: 1.25 or less75 Ω terminal: 1.30 – 1.80

Power Rating

Peak power; measured at pulse width 5 ms max.

Ave.: 0.5 W Peak: 500 W

Connectors

Length 120 cm (4 ft)

BNC type

Impedance 50 ΩCable RG-58A/U

CablesSpecifications

BB-150CBB-120C

150 cm (4.75 ft)

Max. VSWR

Attenuation

1.2

Accuracy ±1 dB (DC, ±0.2 dB)

Frequency Range DC – 2 GHz

Impedance 50 Ω

AttenuatorSpecifications

Connectors BNC feedthrough type

Power Rating

AA-20B

20 dB

Peak power; measured at pulse width 5 ms max.

Ave.: 0.5 W Peak: 500 W

Accessories

p84-End 00.9.28 4:52 PM ページ 84

Page 83: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

85

POWER CORDIwatsu products are equipped with a power cord with a 3-prong plugfor export from Japan.The type of power cord attached varies according to AC line voltage.100 to 120V area : Type D is attached (some model Type C).220 to 240V area : Type E is attached.

Type A and B are for Japan only.Other available types of power cords are listed below. Please specifyyour requirements on your purchase order.

Type DescriptionVoltageRange

UsingAreas

RatedVoltage

Plug ShapeApplied

Specification

250 V,10A

China

UKHong-Kong

Singapore

Europe

Japan, North

America

250 V,10A

Fused

250 V,10A

250 V, 7A

250 V, 6A

CCEE

ASTA

CSA

CEE

ULCSA

180 V –250 V

180 V –250 V

180 V –250 V

90 V –125 V

G

A

B

C

D

E

F

(Used in ITF-014, ITF-02/03/04/05/06/07/, PG-230, SC-340, FG-330.350)

250V-10A-2.5L (for Inlet), length 2.5 m

MP5004 (for Inlet), length 1.8 m

V3203CA (for Inlet), length 1.8 m

P34-SVT-C0025 (for Inlet), length 2.5 m

C33-L3 (for Inlet), length 3 mC33-L2 (for Inlet), length 2 m

C116-L3For Inlet, length 3 m

P6A3VDirect from instruments, length 3 m

p84-End 00.9.28 4:52 PM ページ 85

Page 84: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

86

Iwatsu DistributorsArranged alphabetically by country

INDIA INDIAM.V.Karve & Co. DEALC35, Sopan Society #4 (Basement) Nathan's Arcade,Veer Sawarkar 21, Malaviya Avenue (LB Road),Marg, Thane 400-602 Thiruvanmiyur, Chennai - 41TEL +91-22-543-3912 FAX +91-22-536-6115 TEL +91-44-4919138 FAX +91-44-4919135

INDONESIA INDONESIAPT STIMEC ELCOM P.T. GEMAbangun PROnaperkasaGraha Astri Aniela Anggun Kompleks Mangga Dua Plaza (RUKO)Jalan Tanah Abang III/15, Block G No. 20, JL Mangga Dua RayaJakarta 10160 Jakarta 10730TEL +62-21-352-4821 FAX +62-21-381-2468 TEL +62-21-6121847 FAX +62-21-6120094

HONG KONG & CHINA KOREAMIKO-KINGS INSTRUMENTS LTD. Woojoo HI-TECH CORPRM 615, 6/F, TOWER A, Sinkang Bldg., 160–8 Karak 2-Dong,Hung Hom Commercial Center, Songpa-ku37-39 Matauwai Road, Hung Hom, Kowloon Seoul 138-162TEL +852-2764-0603 FAX +852-2764-0079 TEL +82-2-449-5500 FAX +82-2-449-5523

MALAYSIA MALAYSIASILICON INSTRUMENTATION SDN. BHD. Nihon Denkei (M) SDN. BHD.No. 24A, Jalan SS 19/5, No73&75, Jalan3/76D,Subang Jaya, Desa Pandan47500 Petaling Jaya, 55100Selangor Kuala LumpurTEL +60-3-7347077,7341461 FAX +60-3-7334627 TEL +60-3-9878671 FAX +60-3-9878670

PHILIPPINES SINGAPOREAVESCO MARKETING CORPORATION Silicon instrumentation PTE LTDAurora Blvd. cor. Yale St., 705, Sims Drive #05-04,Cubao, Quezon City Shun Li Industrial Comlex, 387384TEL +63-2-912-8881 FAX +63-2-912-2911 TEL +65-743-3318 FAX +65-743-4818

SINGAPORE TAIWAN R.O.C.Nihon Denkei Co., Ltd. Pau Chung Trading Co., Ltd.Singapore Branch 7F,No.23, Sec. 1,745 Toa Payoh Lorong 5, Chang An East Road#02-02 HBM Building, 319455 TaipeiTEL +65-355-0851 FAX +65-355-0751 TEL +886-2-2561-2211 FAX +886-2-2541-5840

THAILAND THAILANDInternational Reserch Corporation Limited UI ELECTRONICS CO., LTD.23/106-108 Soi Soonvijai, Rama 9 Rd. Home Place Bldg. 283/68,Bangkapi 14 Floor, Soi Thonglor 13,Huay-Kwang Sukhumvit 55, Klongtonnua,Bangkok 10320 Klongtoey, Bangkok 10110TEL +66-2-203-0009 FAX +66-2-203-0260 TEL +66-2-712-7290 FAX +66-2-712-7292

THAILANDNIHON DENKEI (THAILAND) CO., LTD.889 Thai CC Tower 23rd FL.,South Sathorn Rd., YannawaSathorn, Bangkok 10120TEL +66-2-675-5688~91 FAX +66-2-675-5692

p84-End 00.9.28 4:52 PM ページ 86

Page 85: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

84

MT-45• For DS-9121/DS-9122/TS-8422• Two 3-pin power supply sockets• Tray is adjustable in five steps of -10°,

-20°, +10°, and +20° with one-touchoperation of the lever.

Carrying capacity: 50 kg (30 kg for tray, 20 kgfor lower tray)Dimensions: Approx. 468 (W) x 620 (L) mmWeight: Approx. 32 kg

MT-555A• For mid-sized models• Drawer provided under the lower tray

for accessories• Casters with stoppers

Carrying capacity: 40 kg (27 kg for tray, 13 kgfor lower tray)Dimensions: Approx. 500(W) x 500(L) mmWeight: Approx. 17 kg

SCOPE WAGONS

SK-2101A• Designed for use with lightweight

oscilloscopes• Main tray is adjustable in five steps for

easy visibility; 10° down, and 10, 20and 30˚ up

Carrying capacity: Within 17 kg Main tray dimensions: Approx. 330 (W) x 470(L) mm Weight: 13.5 kg approx.

TerminationsSpecifications

BP-50M1 BP-75M1 BB-50M1

Frequency Range DC – 3 GHz DC – 1 GHz

Impedance 50 Ω 75 Ω 50 Ω

Max. VSWR 1.37 (– 1 GHz)1.25 (– 1 GHz)

1.1 (– 500 MHz)1.25 (– 1 GHz)

Power Rating Ave.: 0.5 W Peak: 500 W

Connectors BNC typeplug

BNC typeplug

BNC feed-through type

Peak power; measured at pulse width 5 ms max.

1.1 (– 1 GHz) 1.2 (– 3 GHz)

B-50D3 B-50D4

Impedance 50 ΩFrequency DC – 3 GHz

Nominal Insertion Loss 6 dB 9.5 dB

Max. VSWR

Power Rating Ave.: 2 WPeak: 2 kW*

Ave.: 1 WPeak: 1 kW*

DividersSpecifications

Connectors BNC type

Terminals 3 4

Peak power; measured at pulse width 5 ms max.

1.2

Conversion PadSpecifications

B-5P7J1

Connectors

Frequency Range DC – 2 GHz

BNC feedthrough type

Impedance 50 Ω (BNC-P) – 75 Ω (BNC-J)

VSWR 50 Ω terminal: 1.25 or less75 Ω terminal: 1.30 – 1.80

Power Rating

Peak power; measured at pulse width 5 ms max.

Ave.: 0.5 W Peak: 500 W

Connectors

Length 120 cm (4 ft)

BNC type

Impedance 50 ΩCable RG-58A/U

CablesSpecifications

BB-150CBB-120C

150 cm (4.75 ft)

Max. VSWR

Attenuation

1.2

Accuracy ±1 dB (DC, ±0.2 dB)

Frequency Range DC – 2 GHz

Impedance 50 Ω

AttenuatorSpecifications

Connectors BNC feedthrough type

Power Rating

AA-20B

20 dB

Peak power; measured at pulse width 5 ms max.

Ave.: 0.5 W Peak: 500 W

Accessories

p84-End 00.9.28 4:52 PM ページ 84

Page 86: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

85

POWER CORDIwatsu products are equipped with a power cord with a 3-prong plugfor export from Japan.The type of power cord attached varies according to AC line voltage.100 to 120V area : Type D is attached (some model Type C).220 to 240V area : Type E is attached.

Type A and B are for Japan only.Other available types of power cords are listed below. Please specifyyour requirements on your purchase order.

Type DescriptionVoltageRange

UsingAreas

RatedVoltage

Plug ShapeApplied

Specification

250 V,10A

China

UKHong-Kong

Singapore

Europe

Japan, North

America

250 V,10A

Fused

250 V,10A

250 V, 7A

250 V, 6A

CCEE

ASTA

CSA

CEE

ULCSA

180 V –250 V

180 V –250 V

180 V –250 V

90 V –125 V

G

A

B

C

D

E

F

(Used in ITF-014, ITF-02/03/04/05/06/07/, PG-230, SC-340, FG-330.350)

250V-10A-2.5L (for Inlet), length 2.5 m

MP5004 (for Inlet), length 1.8 m

V3203CA (for Inlet), length 1.8 m

P34-SVT-C0025 (for Inlet), length 2.5 m

C33-L3 (for Inlet), length 3 mC33-L2 (for Inlet), length 2 m

C116-L3For Inlet, length 3 m

P6A3VDirect from instruments, length 3 m

p84-End 00.9.28 4:52 PM ページ 85

Page 87: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

86

Iwatsu DistributorsArranged alphabetically by country

INDIA INDIAM.V.Karve & Co. DEALC35, Sopan Society #4 (Basement) Nathan's Arcade,Veer Sawarkar 21, Malaviya Avenue (LB Road),Marg, Thane 400-602 Thiruvanmiyur, Chennai - 41TEL +91-22-543-3912 FAX +91-22-536-6115 TEL +91-44-4919138 FAX +91-44-4919135

INDONESIA INDONESIAPT STIMEC ELCOM P.T. GEMAbangun PROnaperkasaGraha Astri Aniela Anggun Kompleks Mangga Dua Plaza (RUKO)Jalan Tanah Abang III/15, Block G No. 20, JL Mangga Dua RayaJakarta 10160 Jakarta 10730TEL +62-21-352-4821 FAX +62-21-381-2468 TEL +62-21-6121847 FAX +62-21-6120094

HONG KONG & CHINA KOREAMIKO-KINGS INSTRUMENTS LTD. Woojoo HI-TECH CORPRM 615, 6/F, TOWER A, Sinkang Bldg., 160–8 Karak 2-Dong,Hung Hom Commercial Center, Songpa-ku37-39 Matauwai Road, Hung Hom, Kowloon Seoul 138-162TEL +852-2764-0603 FAX +852-2764-0079 TEL +82-2-449-5500 FAX +82-2-449-5523

MALAYSIA MALAYSIASILICON INSTRUMENTATION SDN. BHD. Nihon Denkei (M) SDN. BHD.No. 24A, Jalan SS 19/5, No73&75, Jalan3/76D,Subang Jaya, Desa Pandan47500 Petaling Jaya, 55100Selangor Kuala LumpurTEL +60-3-7347077,7341461 FAX +60-3-7334627 TEL +60-3-9878671 FAX +60-3-9878670

PHILIPPINES SINGAPOREAVESCO MARKETING CORPORATION Silicon instrumentation PTE LTDAurora Blvd. cor. Yale St., 705, Sims Drive #05-04,Cubao, Quezon City Shun Li Industrial Comlex, 387384TEL +63-2-912-8881 FAX +63-2-912-2911 TEL +65-743-3318 FAX +65-743-4818

SINGAPORE TAIWAN R.O.C.Nihon Denkei Co., Ltd. Pau Chung Trading Co., Ltd.Singapore Branch 7F,No.23, Sec. 1,745 Toa Payoh Lorong 5, Chang An East Road#02-02 HBM Building, 319455 TaipeiTEL +65-355-0851 FAX +65-355-0751 TEL +886-2-2561-2211 FAX +886-2-2541-5840

THAILAND THAILANDInternational Reserch Corporation Limited UI ELECTRONICS CO., LTD.23/106-108 Soi Soonvijai, Rama 9 Rd. Home Place Bldg. 283/68,Bangkapi 14 Floor, Soi Thonglor 13,Huay-Kwang Sukhumvit 55, Klongtonnua,Bangkok 10320 Klongtoey, Bangkok 10110TEL +66-2-203-0009 FAX +66-2-203-0260 TEL +66-2-712-7290 FAX +66-2-712-7292

THAILANDNIHON DENKEI (THAILAND) CO., LTD.889 Thai CC Tower 23rd FL.,South Sathorn Rd., YannawaSathorn, Bangkok 10120TEL +66-2-675-5688~91 FAX +66-2-675-5692

p84-End 00.9.28 4:52 PM ページ 86

Page 88: TEST & MEASURING INSTRUMENTSISO 9000 IWATSU's SS-7840 — SS-7802 analog oscilloscopes and other instruments are manufactured under a quality assurance system in a certified ISO9002

Some of the products are Regulated Products subject to theForeign Exchange and Foreign Trade Control Law of Japan.Export should not be allowed without appropriategovernmental authorization. Please ask our sales officewhether the product concerned is a Regulated Product.

SC(U)-0009-802-2-03

Test and Measuring Equipment Dept.:7-41 1-CHOME KUGAYAMA, SUGINAMI-KU, TOKYO, 168-8501 JAPANTEL:+81-3-5370-5483, FAX:+81-3-5370-5492Homepage: http://www.iwatsu.co.jp/E-Mail Address: [email protected]

The Key toAccuracy and Reliability

Distributed by

岩通総合表1表4 00.9.28 5:05 PM ページ 2