TopLineL_hmv_11302_2011-03_en_DE

Embed Size (px)

Citation preview

  • 8/4/2019 TopLineL_hmv_11302_2011-03_en_DE

    1/32

    The sliding door system with a varietyo options or huge fexibility. TopLine L

  • 8/4/2019 TopLineL_hmv_11302_2011-03_en_DE

    2/322

  • 8/4/2019 TopLineL_hmv_11302_2011-03_en_DE

    3/323

    Sliding doors leave no margin o doubt when

    it comes to practical unctionality and clearly

    deined, purist beauty. Supreme user riendli-

    ness and individually tailored design versatility

    make them the ideal answer to the demands

    o modern living. The TopLine L sliding door

    itting rom Hettich satisies these demands

    with perection rom ease o installation to

    convenience o use.

    Combination with the Silent System Flexible 50

    and 80 gently closing systems provides addedconvenience. This way, even heavy, large doors

    reliably close with a mere whisper. That's advan-

    ced technology rom Hettich.

    A talented all-rounder with many qualitiesTopLine L

  • 8/4/2019 TopLineL_hmv_11302_2011-03_en_DE

    4/324

    The easy-to-install sliding door systemwith integrated height adjustment eatureTopLine L

  • 8/4/2019 TopLineL_hmv_11302_2011-03_en_DE

    5/325

    Suitable or use with door thicknesses ranging

    rom 16 to 40 mm, TopLine L easily meets the

    modern-day wish or individuality and ultimate

    lexibility.

    The same running and guiding components can

    be used or solid and aluminium-ramed ronts.

    TopLine L provides an astonishing range o op-

    tions or selecting aluminium door rame pro-

    iles. The multitalented itting among sliding

    door hardware ensures unrestricted use rom

    a rame width o just 50 mm.

    The doors are simply placed onto the running

    proile. Quick-mounting guiding components

    guarantee the greatest possible convenience

    right rom the word go. The guides simply clip

    into the bottom guidingproile.

    Height is conveniently adjusted with the doors

    in place without having to undo the ixing screws

    on the runners. This also makes child's play o

    positioning doors or neat gap alignment.

    Perected design to excite, lasting quality and

    impressive user riendliness: TopLine L sets new

    standards or tomorrow's urniture.

    Technical details in brief

    2-track, top-running

    sliding door tting Overlay door position

    Door weight up to 50 kg

    Door height up to 2600 mm

    Door width 700 mm - 1500 mm

    Door thickness16, 18, 19, 21, 22, 25, 40 mm

    Height adjustment 3 mm

    Rack plated running and guidingcomponents

    2 opening options:completely parallel or oset whenusing projecting handles

    Quick-mounting guiding components

  • 8/4/2019 TopLineL_hmv_11302_2011-03_en_DE

    6/326

    Hettich and the environment: committed to responsiblepractice, active protection, innovative thinking.

    Hettich takes a responsibility or the world we live in. This awa-

    reness deines the strict policy o environmental management

    we practise. Our environmental oicer has taken personal re-

    sponsibility or these aspects throughout the company group

    over a period o many years. In addition, a separate environment

    committee has been established or each production site. We

    regard statutory provisions as minimum requirements. At signii-

    cant sites we also implement the stringent EMAS Directive. And

    we drive orward developments that in uture will help to save

    even more raw materials and support the necessary endeavours

    towards sustainability.

    Hettich environmental management

    Hettich started introducing eective environmental management

    systems under the stringent EMAS Regulation (currently: EC Re-

    gulation No. 761/2001, including EN ISO 14.001/2004) as long ago

    as 1996. This not only enables us to improve our environmental

    perormance on a broad ront but also achieve a high level o

    saety which, not least, also beneits our customers. This is why

    we also require our suppliers to meet the necessary minimum

    standards o environmental protection, industrial saety, health

    care and social welare.

    The results achieved in the drawer-runner and drawer-system

    product segment at the Kirchlengern operation illustrate the

    impressive eects these measures have and veriiably demon-

    strate our tireless endeavours to translate words into action:

    Relie to the environment between 1997 and 2008:

    Speciic water consumption: 56 per cent

    Speciic power consumption: 21 per cent

    Speciic heat consumption: 84 per cent

    Speciic CO2

    emissions: 29 per cent

  • 8/4/2019 TopLineL_hmv_11302_2011-03_en_DE

    7/327

    Hettich standard for product materials

    Hettich underpins its commitment by applying an internal

    standard or product materials. This ensures that every pro-

    duct rom production to disposal satisies all environ-

    mental requirements. Products rom Hettich come with a

    long lie. Appropriately oresighted, our rigorous standards

    are ormulated to ensure that international legislation is

    met as well. This provides a reliable basis or marketing

    urniture world-wide.

    Zero-energy building - Hettich Forum

    The Hettich Forum building with its neutral energy balance is

    a shining example o uture-proo building design.

    Photovoltaic panels and solar collection system providing hot

    water as well as extensive roo greening and use o rain water

    underscore this building's overall sustainability concept in just

    the same way as the broad use o cellulose insulation material

    rom recycled newspapers, highly eicient heat recovery and

    the bulb-ree lighting concept do.

    With the Hettich Group having acquired European Commissi-

    on GreenBuilding Partner status on 5 March 2009, the com-

    prehensive approach demonstrated by the Hettich Forum has

    also convinced the adjudicating panel o the national "Green

    Building Award 2009". Hettich received the irst prize to be

    presented in the "New Building" category.

  • 8/4/2019 TopLineL_hmv_11302_2011-03_en_DE

    8/32

    10

    8

    Sliding door system TopLine LQuality that meets all of demands

    Horizontal safety test

    Pressure is applied to the middle o the door with a

    dened orce. The door must neither come o or allout o the carcase.

    Endurance test

    The door is required to withstand a specic number

    o opening and closing cycles at a dened speed.

    Closing test

    The door is required to withstand a specic number o

    closing cycles perormed under a dened tensile load.

    Test to DIN EN 15706

    Lift-out guard

    The door is pulled up and orwards at an angle with adened orce and must neither come o or all out o

    the cabinet.

    Quality criteria

    Endurance test over 40,000 cycles

    Closing test with a tensile load o 4 kg Lit-out test with 250 N

    Load test in horizontal directionwith 250 N

    The TopLine L sliding door system is constantly moni-

    tored or quality. The varying quality standards de-

    manded by dierent markets and segments are each

    taken into account. The diagrams below show exam-ples o some o the testing processes and what they

    involve.

  • 8/4/2019 TopLineL_hmv_11302_2011-03_en_DE

    9/32

    l l

    l

    l -

    l l -l

    ll l

    l l -

    l -

    l

    l - l l

    l

    l l -l

    l l -l

    l -

    9

    Test to DIN EN 15706

    Sliding door system TopLine LInstallation options

    3-panel

    2-panel,inner panel right

    2-panel,inner panel left

    Rear-most doorRunner let long pin

    Rear-most doorRunner let long pin

    Rear-most doorRunner let short pin

    Front-most doorRunner let

    Front-most doorRunner let

    Front-most doorRunner right

    Front-most doorRunner right

    Rear-most doorRunner right short pin

    Rear-most doorRunner rightshort pin

    Rear-most doorRunner right long pin

    Rear-most doorRunner right long pin

    Front-most doorRunner right

    Front-most doorRunner let

    Rear-most doorRunner let short pin

  • 8/4/2019 TopLineL_hmv_11302_2011-03_en_DE

    10/32

  • 8/4/2019 TopLineL_hmv_11302_2011-03_en_DE

    11/32

  • 8/4/2019 TopLineL_hmv_11302_2011-03_en_DE

    12/32

    6,2

    min. 160

    c 230

    6,26,2

    13

    230

    5,5

    6,2

    c

    max. 320

    a1

    30-50

    35

    min. 160max. 320

    a1

    30-50

    6,26,2

    min. 160max. 320

    c 230

    6,26,2

    13

    230

    35

    5,5

    c

    a1

    30-50min. 160max. 320

    a1

    30-50

    min. 160max. 320

    309

    6,4

    a130-100

    aX

    Gesamtlnge

    12

    Sliding door system TopLine LInstallation in front of top panelInformation for ordering running proles and running components

    Article Colour MM*Order no.

    TopLine L running profile

    Any length on request

    Steel LA 02233 100 1

    Aluminium silver LA 01233 100 1

    TopLine L covering profile

    Any length on requestPlastic grey LA 01341 100 1

    * MM = Minimum

    ** Quantity required for 2-door unit

    Quantity **

    Overall length

  • 8/4/2019 TopLineL_hmv_11302_2011-03_en_DE

    13/3213

    Article left / rightEB PU* MM* Quantitya) *

    Quantityb) *

    Quantityc) *

    Quantityd) *

    Quantitye) *

    Order no.

    let (pic.) 911 924 4 50 100 1 1

    right 911 924 3 50 100 1 1

    TopLine L runnerfor rear-most door,with long pin

    For projectinghandles, positionedat cabinet side

    With ball-bearingroller With height-adjuster

    let (pic.) 911 924 5 50 100 1 1 1 2

    right 911 924 6 50 100 1 1 1 2

    TopLine L runnerfor rear-most door,with short pin

    For projectinghandles, positionedat cabinet centre

    For doors openingparallel with each other,positioned at cabinetside and cabinet centre

    With ball-bearing roller With height adjuster Galvanised steel

    28 let (pic.) 911 926 2 50 100 1 1 1 1 1

    right 911 926 3 50 100 1 1 1 1 1

    31 let 911 926 5 50 100 1 1 1 1 1

    right 911 926 6 50 100 1 1 1 1 1

    34 let 911 926 7 50 100 1 1 1 1 1

    right 911 926 8 50 100 1 1 1 1 1

    37 let 911 926 9 50 100 1 1 1 1 1

    right 911 927 0 50 100 1 1 1 1 1

    TopLine L runner

    for front-most door With ball-

    bearing roller With height

    adjustment Galvanised steel

    * PU = Packaging units MM = Minimum

    a) Quantity required or 2-door unit, let door ront-mostb) Quantity required or 2-door unit, right door ront-most

    c) Quantity required or 3-door unit

    d) Parallel opening, 2-door

    e) Parallel opening, 3-door

    TopLine L runnerfor front-most doorEB 52

    With ball-bearing roller

    With height adjustment Galvanised steel

    52 let (pic.) 911 927 1 50 100 1 1 1 1 1

    right 911 927 2 50 100 1 1 1 1 1

  • 8/4/2019 TopLineL_hmv_11302_2011-03_en_DE

    14/32

  • 8/4/2019 TopLineL_hmv_11302_2011-03_en_DE

    15/32

  • 8/4/2019 TopLineL_hmv_11302_2011-03_en_DE

    16/32

    c c

    6,2 6,2

    b1 95 4,1

    8

    34

    35

    min. 160max. 320

    309

    6,4

    a130-100

    aX

    Gesamtlnge

    16

    Sliding door system TopLine LInstallation on top of top panelInformation for ordering running proles and running components

    Article Colour MM* Quantity **Order no.

    TopLine L running profile

    Any length on request

    Aluminium silver LA 10150 100 1

    TopLine L covering profile

    Any length on requestPlastic grey LA 01341 100 1

    * MM = Minimum

    ** Quantity required for 2-door unit

    Overall length

  • 8/4/2019 TopLineL_hmv_11302_2011-03_en_DE

    17/3217

    Article left / rightEB PU* MM* Quantityd) *

    Quantitye) *

    Order no.

    let (pic.) 911 924 7 50 100 1 1

    right 911 925 0 50 100 1 1

    let (pic.) 911 924 9 50 100 1 1 1 2

    right 911 926 1 50 100 1 1 1 2

    TopLine L runnerfor rear-most door,with long pin

    For projectinghandles, positionedat cabinet side

    With ball-bearing roller With height-adjuster

    TopLine L runnerfor rear-most door,with short pin

    For projectinghandles, positionedat cabinet centre

    For doors openingparallel with each other,positioned at cabinetside and cabinet centre

    With ball-bearing roller With height adjuster Galvanised steel

    28 let (pic.) 911 926 2 50 100 1 1 1 1 1

    right 911 926 3 50 100 1 1 1 1 1

    31 let 911 926 5 50 100 1 1 1 1 1

    right 911 926 6 50 100 1 1 1 1 1

    34 let 911 926 7 50 100 1 1 1 1 1

    right 911 926 8 50 100 1 1 1 1 1

    37 let 911 926 9 50 100 1 1 1 1 1

    right 911 927 0 50 100 1 1 1 1 1

    TopLine L runner

    for front-most door With ball-

    bearing roller With height adjustment Galvanised steel

    TopLine L runnerfor front-most doorEB 52

    With ball-bearing roller

    With height adjustment Galvanised steel

    52 let (pic.) 911 927 1 50 100 1 1 1 1 1right 911 927 2 50 100 1 1 1 1 1

    Quantitya) *

    Quantityb) *

    Quantityc) *

    * PU = Packaging units MM = Minimum

    a) Quantity required or 2-door unit, let door ront-mostb) Quantity required or 2-door unit, right door ront-most

    c) Quantity required or 3-door unit

    d) Parallel opening, 2-door

    e) Parallel opening, 3-door

  • 8/4/2019 TopLineL_hmv_11302_2011-03_en_DE

    18/32

    min. 15max. 22

    min. 25

    EB 28 - 52 13

    7

    16

    35

    8

    24,5

    Y XX 8

    13

    11,5

    32

    5,2

    min. 15max. 22

    min. 55Sockelhhe

    24

    13

    34min. 46

    20

    7

    fix 24

    3,5

    min. 15max. 22

    min. 25

    EB 28 - 52 13

    7

    16

    35

    8

    24,5

    X XY 8

    13

    11,5

    32

    5,2

    13

    min. 15max. 22

    min. 55Sockelhhe

    24

    1334

    min. 46

    20

    7

    fix 24

    3,5

    1

    8

    5

    c = 49,5 versetztes ffnenc = 52,5 deckungsgleiches ffnen

    4,5 x 25

    18

    Sliding door system TopLine LInstallation in front of bottom panelFitting situation for running proles and running components

    Wooden door Aluminium frame door

    DoorthicknessX

    DistancebetweendoorsY

    Instal-lationwidthEB

    16 12 28

    18 13 31

    19 12 31

    21 13 34

    22 12 34

    25 12 37

    40 12 52

    End stop position

    plinth heightplinth height

    oset opening

    parallel opening

  • 8/4/2019 TopLineL_hmv_11302_2011-03_en_DE

    19/32

    8,1 5,5

    24

    min. 160max. 320

    5,5

    a130-50

    8c c

    8

    19

    Sliding door system TopLine LInstallation in front of bottom panelInformation for ordering running proles and running components

    28 911 931 0 100 100 2 2 2

    31 911 931 2 100 100 2 2 2

    34 911 931 3 100 100 2 2 2

    37 911 931 4 100 100 2 2 2

    52 911 931 5 100 100 2 2 2

    911 930 8 100 100 2 2 4

    LA 01171 100 1 1 1Guiding profile STB 15

    Proile positioned inront o bottom panel

    Any length on request Aluminium

    Guiding STB 15for rear-most door

    Proile positioned inront o bottom panel

    With plastic glide Galvanised steel

    Guiding STB 15for front-most door

    Proile positioned inront o bottom panel

    With plastic glide Galvanised steel

    Article EB PU* MM*Order no. Quantitya) *

    Quantityb) *

    Quantityc) *

    * PU = Packaging units MM = Minimuma) Quantity required or 2-door unit, let door ront-most

    b) Quantity required or 2-door unit, right door ront-most

    c) Quantity required or 3-door unit

  • 8/4/2019 TopLineL_hmv_11302_2011-03_en_DE

    20/32

    19,5

    20

    c = 12,5 versetztes ffnenc = 15,5 deckungsgleiches ffnen

    1

    5

    2x 4 x 20

    20

    1

    5c = 12,5 versetztes ffnenc = 15,5 deckungsgleiches ffnen

    19,5

    2x 4 x 20

    EB 28 - 52 8

    19

    min. 255,2

    11,5

    32

    34

    X Y X 8

    7

    16 3560

    13

    4 x 25

    5

    34

    34

    46

    min. 15max. 22

    min. 60Sockelhhe

    25

    30

    8,5

    7fix 30

    3,5

    EB 28 - 52 8

    19

    min. 255,2

    11,5

    32

    34

    X Y X 8

    7

    16 3560

    13

    13

    4 x 25

    5

    34

    34

    46

    min. 15max. 22

    min. 60Sockelhhe

    25

    30

    8,5

    7fix 30

    3,5

    20

    Wooden door Aluminium frame door

    Sliding door system TopLine LInstallation below bottom panelFitting situation for running proles and running components

    DoorthicknessX

    DistancebetweendoorsY

    Instal-lationwidthEB

    16 12 28

    18 13 31

    19 12 31

    21 13 34

    22 12 34

    25 12 37

    40 12 52

    End stop position

    Rear-mostdoor

    Front-mostdoor

    oset openingparallel opening

    oset openingparallel opening

    plinth heightplinth height

  • 8/4/2019 TopLineL_hmv_11302_2011-03_en_DE

    21/32

    11,5

    19,5 4

    5

    min. 160

    max. 320

    a1

    30-50

    21

    Article EB PU* MM*Order no. Quantitya) *

    Quantityb) *

    Quantityc) *

    * PU = Packaging units MM = Minimuma) Quantity required or 2-door unit, let door ront-most

    b) Quantity required or 2-door unit, right door ront-most

    c) Quantity required or 3-door unit

    Sliding door system TopLine LInstallation below bottom panelInformation for ordering running proles and running components

    911 910 6 100 100 2 2 4

    28 911 927 9 100 100 2 2 2

    31 911 928 0 100 100 2 2 2

    34 911 930 1 100 100 2 2 2

    37 911 930 2 100 100 2 2 2

    52 911 930 4 100 100 2 2 2

    LA 00619 100 1 1 1Guiding profile STB 11

    Proile positionedbelow bottom panel

    Any length on request Aluminium

    Guiding STB 11for front-most door

    Proile positionedbelow bottom panel

    With plain-bearing roller Galvanised steel

    Guiding STB 11for rear-most door

    Proile positionedbelow bottom panel

    With plain-bearing roller Galvanised steel

  • 8/4/2019 TopLineL_hmv_11302_2011-03_en_DE

    22/3222

    Sliding door system TopLine LSystem components for both mounting options

    Article PU* MM*Order no.

    Support block for running profile

    Attachment with 3.5 mm chipboard screws

    Plastic grey

    End stop for running profilefor offset opening

    Not required whenusing Silent System

    Plastic grey

    End stop for running profilefor parallel opening

    Not required whenusing Silent System

    Plastic grey

    Hexagon head screwM6 x 16 mm

    For attaching runningproile end stop

    Galvanised steel

    M6 hexagon nut

    For attaching runningproile end stop

    Galvanised steel

    TopLine L centre stop

    For ront-most door Plastic grey

    Mounting aid forfront-mounted running profile

    When using LA 01233and LA 02233 running proile

    Mounting aid fortop-mounted running profile

    When using LA 10150running proile

    107 830 8 1000 1000 2 2 2

    911 851 5 500 500 2 2 2

    100 900 9 1000 1000 2 2 2

    902 031 9 50 500 2 2 2

    911 820 1 500 500 2 2 2

    107 831 1 500 500 - - 1

    911 992 6 500 500 2 2 4

    911 992 7 500 500 2 2 4

    On request, end stops can be delivered premounted

    On request, end stops can be delivered premounted

    On request, end stops can be delivered premounted

    Quantitya) *

    Quantityb) *

    Quantityc) *

    * PU = Packaging units MM = Minimuma) Quantity required or 2-door unit, let door ront-most

    b) Quantity required or 2-door unit, right door ront-most

    c) Quantity required or 3-door unit

  • 8/4/2019 TopLineL_hmv_11302_2011-03_en_DE

    23/3223

    Article PU* MM*Order no.

    Special screw 4 x 20 mm

    For attaching end stopo guiding proile STB 11

    Galvanised steel

    Mounting plate for

    guiding components

    End stop forguiding profile STB 11

    When using > EB 37 Must only be used with

    Silent System Flexible 50

    End stop forguiding profile STB 11

    When using > EB 37 Must only be used with

    Silent System Flexible 50

    End stop for guidingprofile STB 15

    Mounted withchipboard screw

    912 046 3 1000 1000 5 5 4

    911 834 8 500 500 4 4 6

    911 992 8 500 500 2 2 2

    911 993 0 500 500 2 2 2

    911 251 1 1000 1000 2 2 2

    Quantitya) *

    Quantityb) *

    Quantityc) *

    * PU = Packaging units MM = Minimuma) Quantity required or 2-door unit, let door ront-most

    b) Quantity required or 2-door unit, right door ront-most

    c) Quantity required or 3-door unit

  • 8/4/2019 TopLineL_hmv_11302_2011-03_en_DE

    24/32

    2

    3

    3

    1

    2

    1

    24

    Sliding door system TopLine LInstallation

    Installing running and guiding profile

    Mounting end stop

    for guiding profile STB 11

    Please always carry out trial door mounting.

    Front-most door

    Rear-most door

  • 8/4/2019 TopLineL_hmv_11302_2011-03_en_DE

    25/32

    32 32 32

    Trbild oben

    Trbild unten

    11,5

    32

    32

    32

    35

    67 3232

    STB 11 = 25

    5

    STB 15 = 20

    5

    5

    32 32 32

    Trbild oben

    Trbild unten

    11,5

    32

    32

    32

    35

    67 3232

    STB 11 = 25

    5

    STB 15 = 20

    5

    5

    50

    32 32 32

    Trbild oben

    Trbild unten

    11,5

    32

    32

    32

    35

    67 3232

    STB 11 = 25

    2,5

    2,5

    STB 15 = 20

    5

    5

    4

    95

    4

    3,5 x 20

    8

    95

    32

    11,5

    3564

    95

    129,5

    32

    11,

    3564

    25

    Please always carry out trial door mounting.

    Aluminium frame doorWooden doorInstallation centre stop

    Drilling patterns on the door

    EB 28-37

    EB 52

    drilling patternat top

    drilling patternat bottom

    drilling patternat top

    drilling patternat bottom

    drilling patternat top

    drilling patternat bottom

  • 8/4/2019 TopLineL_hmv_11302_2011-03_en_DE

    26/3226

    Removing safety guardRear-most door

    Sliding door system TopLine LInstallation

    Installing runners

    Rear-most door

    Front-most door

    Installing guiding components STB 11 STB 15

    Please always carry out trial door mounting.

  • 8/4/2019 TopLineL_hmv_11302_2011-03_en_DE

    27/32

    1 2

    3

    12

    43 4

    4

    2,5

    27

    Height adjustmentFront-most door

    Rear-most door

    Please always carry out trial door mounting.

    I a door is set high up, the guiding components canbe lowered by 4.0 mm i necessary (e.g. STB 11).

  • 8/4/2019 TopLineL_hmv_11302_2011-03_en_DE

    28/32

    5

    16,5

    23

    14

    = 66 a2 = 128

    Gesamtlnge

    a1 a7

    =256

    a8

    = 288 aX

    5

    20

    14

    = 66 a2 = 128

    Gesamtlnge

    16,5

    29

    a1 a7

    =256

    a8

    = 288 aX

    5

    23

    14

    min. 45 a2

    Gesamtlnge

    min. 4519,5

    29

    a1 a1

    28

    Door handle profile For door thicknesses o 15 - 16 mm Any length on request

    Door handle profile

    For door thicknesses o 18 - 19 mm Any length on request

    Door end profile, L-shaped

    For door thicknesses o 15 - 16 mm Any length on request

    Article Order no.

    Sliding door system TopLine LSystem componentsDoor and cabinet proles

    Working principle

    The cabinet end profiles allow a cabinet constructionto be used for hinged doors or sliding doors.

    Door handleprole

    Door handleprole

    Door handleprole

    Door handleprole

    Door handleprole

    Door handleprole

    Door handleprole

    Door end prole,U-shaped

    Door end prole,L-shaped

    Brush sealingstrip

    Brush sealingstrip

    MM* Quantitya) *

    Quantityb) *

    Overall length

    Overall length

    Overall length

    Steel silver(protective ilm)

    LA 10197 on request 3 4

    Aluminiumanodised

    LA 10333 100 3 4

    Steel silver(protective ilm)

    LA 10198 on request 3 4

    Steelgalvanised

    LA 10203 on request 1

    Aluminiumanodised

    LA 10336 100 1

    Colour

  • 8/4/2019 TopLineL_hmv_11302_2011-03_en_DE

    29/32

    8

    7

    5

    23,75

    16,5

    14

    = 66 a2 = 128

    Gesamtlnge

    a1 a7

    =256

    a8

    = 288 aX

    5

    20,75

    14

    min. 45 a2

    Gesamtlnge

    min. 4519,5a1 a1

    29

    Door end profile, U-shaped

    For door thicknesses o 15 - 16 mm Any length on request

    Door end profile, U-shaped For door thicknesses o 18 - 19 mm Any length on request

    Article Order no.

    Brush sealing strip

    Sel-adhesive For dust-proo seals Any length on request

    MM* Quantitya) *

    Quantityb) *

    * PU = Packaging units MM = Minimum

    a) Quantity required or 2-door unit

    b) Quantity required or 3-door unit

    Connecting plate

    For connection o segmentedsliding door ront panels

    Overall length

    Overall length

    Steel silver

    (protective ilm)

    LA 10199 on request 2

    Aluminiumanodised

    LA 10337 100 2

    Steel silver(protective ilm)

    LA 10200 on request 2

    LA 10209 100

    Steelgalvanised

    911 013 2

    Colour

  • 8/4/2019 TopLineL_hmv_11302_2011-03_en_DE

    30/32

    min. 15max. 22

    min. 25

    EB 28 - 52

    13

    24,5

    X Y X 8

    13

    11,5

    32

    5,2

    46

    36,25

    13

    EB 28 - 52 8

    19

    min. 255,2

    11,5

    32

    34

    X Y X 8

    7

    1636,25 60

    13

    13

    34

    4 x 25

    5

    30

    Installation in ront o top panel

    Installation on top o ront panel

    Sliding door system TopLine LSystem componentsGently closing system for sliding doors

    Working principle

    The optional Silent System Flexible 50 and Silent System Flexible 80 gently

    closing systems provide evenly cushioned closure no matter how ast the

    door is closed by the user.

    Silent System Flexible 80

    Article PU* MM*Order no.

    Set Silent System Flexible 80,without adapter

    Support bracket Essential

    907 809 7 1 100 1 1

    905 236 4 100 100 1 1

    Quantitya) *

    Quantityb) *

    * PU = Packaging units MM = Minimum

    a) Quantity required for 2-door unit

    b) Quantity required for 3-door unit

  • 8/4/2019 TopLineL_hmv_11302_2011-03_en_DE

    31/32

    min. 15

    max. 22

    min. 25

    EB 28 - 52 13

    7

    16

    35

    8

    24,5

    13

    11,5

    32

    5,2

    72

    X Y X 8

    31

    Silent System Flexible 50

    Article PU* MM*Order no.

    Set Silent System Flexible 50for installation width of 28 / 31 / 34 / 37

    Includes new activator

    Set Silent System Flexible 50for installation width of 52

    Includes new activator

    911 980 2 1 100 1 -

    911 980 3 1 100 - 1

    912 551 1 1 100 1 -

    911 980 3 1 100 - 1

    Quantitya) *

    Quantityb) *

    * PU = Packaging units MM = Minimum

    a) Quantity required for 2-door unit

    b) Quantity required for 3-door unit

  • 8/4/2019 TopLineL_hmv_11302_2011-03_en_DE

    32/32

    1009-023-TLL-0311-HMV/ENGHettich Marketing-und Vertriebs GmbH & Co. KG

    Vahrenkampstrasse 12-16

    32278 Kirchlengern

    Germany

    Phone +49 5223 77-0

    Fax +49 5223 77-1948

    [email protected]

    www.hettich.com