    A330-300TECHNICAL TRAINING MANUAL

    GENERAL FAMILIARIZATION COURSE

    21 AIR CONDITIONING

    GE Metric

  • 8/12/2019 TTM GEN FAM 21

    2/146

  • 8/12/2019 TTM GEN FAM 21

    3/146

    This document must be used

    for training purpose only.

    Under no circumstances

    should this document be used as a reference.

    All rights reserved.

    No part of this manual may be reproduced in any form,

    by photostat, microfilm, retrieval system, or any other means,

    without the prior written permission of Airbus Industrie.

  • 8/12/2019 TTM GEN FAM 21

    4/146

  • 8/12/2019 TTM GEN FAM 21

    5/146

    ** System Presentation (1) 1..................................

    System Controls and Indicating - General (1) 7...........................

    TEMPERATURE CONTROL

    ** System Design Philosophy (1) 15..............................

    ** System Controls and Indicating (1) 19............................

    ** Pack Presentation (1) 29.................................

    ** ECAM Page Presentation (1) 35..............................

    COCKPIT/CABIN VENTILATION

    ** System Presentation (1) 53................................

    ** System Controls and Indicating (1) 59............................

    AFT GALLEY HEATING

    ** System Presentation (1) 63................................

    AVIONICS/AIR CONDITIONING BAY VENTILATION

    ** System Presentation (1) 67................................

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    F5M0100GEMetric

    _

    F5M0100 TABLE OF CONTENTS

    DATE : JUN 1999 Page i F5M0121

  • 8/12/2019 TTM GEN FAM 21

    6/146

    ** System Controls and Indicating (1) 73............................

    ** Avncs Eqpt Gnd Cooling Sys Ctl & Indicating (1 77......................

    FWD CARGO COMPT VENT/TEMP CONTROL

    ** System Presentation (1) 81................................

    ** System Controls and Indicating (1) 87............................

    AFT CARGO COMPARTMENT VENTILATION

    System Presentation (1) 93.................................

    System Controls and Indicating (1) 97.............................

    BULK CARGO COMP VENTILATION/HEATING

    ** System Presentation (1) 101...............................

    ** System Controls and Indicating (1) 105...........................

    PRESSURIZATION

    System Design Philosophy (1) 111..............................

    ** System Controls and Indicating (1) 115...........................

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    F5M0100GEMetric

    _

    F5M0100 TABLE OF CONTENTS

    DATE : JUN 1999 Page ii F5M0121

  • 8/12/2019 TTM GEN FAM 21

    7/146

  • 8/12/2019 TTM GEN FAM 21

    8/146

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    F5M0100GEMetric

    _

    F5M0100 TABLE OF CONTENTS

    DATE : JUN 1999 Page iv F5M0121

    THIS PAGE INTENTIONALLY LEFT BLANK

  • 8/12/2019 TTM GEN FAM 21

    9/146

    SYSTEM PRESENTATION

    IntroductionPresentation

    21 - AIR CONDITIONING

    DATE : SEP 1996 Page 1 F21G010

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    Page 1

    _

    F5M0100GEMetric

  • 8/12/2019 TTM GEN FAM 21

    10/146

  • 8/12/2019 TTM GEN FAM 21

    11/146

    21 - AIR CONDITIONING

    DATE : SEP 1996 Page 3 F21G010

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    Page 3

    _

    F5M0100GEMetric

  • 8/12/2019 TTM GEN FAM 21

    12/146

    PRESENTATION

    Bleed air coming from pneumatic system is controlled in flow before

    reaching two air conditioning packs which ensure basic temperatureregulation.Air delivered by the packs is mixed with recirculated air from the cabin zoneswhich is also used for avionics ventilation purpose.

    Fine temperature adjustment of air distributed in the pressurized zones isobtained by controlling the amount of hot air added to the air coming fromthe mixer unit.

    Correct pressurization is obtained by controlling the conditioned air dischargethrough two outflow valves.

    21 - AIR CONDITIONING

    DATE : SEP 1996 Page 4 F21G010

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    Page 4

    _

    F5M0100GEMetric

  • 8/12/2019 TTM GEN FAM 21

    13/146

    21 - AIR CONDITIONING

    DATE : SEP 1996 Page 5 F21G010

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    Page 5

    _

    F5M0100GEMetric

  • 8/12/2019 TTM GEN FAM 21

    14/146

    STUDENT NOTES

    21 - AIR CONDITIONING

    DATE : SEP 1996 Page 6 F21G010

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    Page 6

    _

    F5M0100GEMetric

  • 8/12/2019 TTM GEN FAM 21

    15/146

    SYSTEM CONTROLS AND INDICATING -

    GENERAL

    Overhead Panel

    Main Instrument PanelForward Attendant Panel

    21 - AIR CONDITIONING

    DATE : APR 1999 Page 1 F21G210

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    Page 7

    _

    F5M0100GEMetric

  • 8/12/2019 TTM GEN FAM 21

    16/146

    OVERHEAD PANELThe air conditioning system controls are located on the overhead panel.

    21 - AIR CONDITIONING

    DATE : APR 1999 Page 2 F21G210

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    Page 8

    _

    F5M0100GEMetric

  • 8/12/2019 TTM GEN FAM 21

    17/146

    21 - AIR CONDITIONING

    DATE : APR 1999 Page 3 F21G210

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    Page 9

    _

    F5M0100GEMetric

  • 8/12/2019 TTM GEN FAM 21

    18/146

    MAIN INSTRUMENT PANELThe air conditioning system can be monitored on the ECAM system display.System information is shown on the following pages :

    - BLEED page : pack and emergency ram air.- AIR COND page : temperature control, cabin ventilation, cargoventilation, cooling and heating (optional).

    - PRESS page : pressurization and avionics ventilation.- CRUISE page : zone temperature and main pressurization systemparameters.

    21 - AIR CONDITIONING

    DATE : APR 1999 Page 4 F21G210

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    Page 10

    _

    F5M0100GEMetric

  • 8/12/2019 TTM GEN FAM 21

    19/146

    21 - AIR CONDITIONING

    DATE : APR 1999 Page 5 F21G210

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    Page 11

    _

    F5M0100GEMetric

  • 8/12/2019 TTM GEN FAM 21

    20/146

    FORWARD ATTENDANT PANELAt the forward attendant station, the Programming and Indication Moduleallows cabin crew to slightly adjust the temperature regulation in the threecabin zones.

    21 - AIR CONDITIONING

    DATE : APR 1999 Page 6 F21G210

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    Page 12

    _

    F5M0100GEMetric

  • 8/12/2019 TTM GEN FAM 21

    21/146

    21 - AIR CONDITIONING

    DATE : APR 1999 Page 7 F21G210

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    Page 13

    _

    F5M0100GEMetric

  • 8/12/2019 TTM GEN FAM 21

    22/146

    STUDENT NOTES

    21 - AIR CONDITIONING

    DATE : APR 1999 Page 8 F21G210

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    Page 14

    _

    F5M0100GEMetric

  • 8/12/2019 TTM GEN FAM 21

    23/146

    TEMPERATURE CONTROL:

    SYSTEM DESIGN PHILOSOPHY

    Basic Principle

    Pack ControllersZone ControllerSelf Examination

    21 - AIR CONDITIONING

    DATE : DEC 1997 Page 1 F21TA02

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    Page 15

    _

    F5M0100GEMetric

  • 8/12/2019 TTM GEN FAM 21

    24/146

    BASIC PRINCIPLEAir flow is regulated by two flow control valves. Two packs provide air basictemperature regulation.Both packs provide air at the same temperature.Trim air pressure regulating valves maintain the downstream pressure abovethe cabin pressure allowing hot air and cold air to be mixed.

    Trim air valves optimize the temperature by adding hot air to pack air supply,when necessary.A part of cabin air is recirculated to decrease air supply demand.

    PACK CONTROLLERS

    Each Pack Controller provides:- basic temperature regulation of its associated pack in accordancewith the demand from the zone controller.

    - and flow control setting and monitoring.

    ZONE CONTROLLERThe Zone Controller provides:

    - A basic temperature regulation signal elaboration which is the lowestdemanded zone temperature.- An optimized temperature control which is the demandedtemperature on the control panel.

    - An optimized flow control demand.Optimized temperature is provided by control of the trim air valves.In case of cooling demand not satisfied due to low air flow, the zone

    controller sends a signal to the EIVMU or ECB in order to provide necessaryflow to the packs.EIVMU : Engine Interface Vibration and Monitoring Unit.ECB : Electronic Control Box (APU).If the selected temperature cannot be maintained, the bleed monitoring

    computer receives a signal in order to control the bleed air deliveredtemperature, at a decreased level.The bleed air temperature is reduced from 200C to 150C. This mode isinhibited if the wing anti-ice system is in operation.

    21 - AIR CONDITIONING

    DATE : DEC 1997 Page 2 F21TA02

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    Page 16

    _

    F5M0100GEMetric

  • 8/12/2019 TTM GEN FAM 21

    25/146

    21 - AIR CONDITIONING

    DATE : DEC 1997 Page 3 F21TA02

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    Page 17

    _

    F5M0100GEMetric

  • 8/12/2019 TTM GEN FAM 21

    26/146

    SELF EXAMINATION

    What is the purpose of the pack?

    A - To regulate hot air pressure.

    B - To adjust the temperature in the four zones.C - To regulate basic temperature.

    What is the function of each pack controller?

    A - To control the corresponding pack and flow control valve.B - To control the trim air valves.

    C - To control the zone controller.

    What is the purpose of the zone controller?

    A - To control zone temperature.B - To control the flow control valves.C - To control the packs.

    21 - AIR CONDITIONING

    DATE : DEC 1997 Page 4 F21TA02

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    Page 18

    _

    F5M0100GEMetric

  • 8/12/2019 TTM GEN FAM 21

    27/146

    TEMPERATURE CONTROL:

    SYSTEM CONTROLS AND INDICATING

    AIR Panel

    Ram Air Pushbutton SwitchPack 1(2) Pushbutton Switches

    Pack Flow SelectorZone Temp SelectorsHot Air 1(2) Pushbutton Switches

    P.I.M.Cabin Temp HardkeyTemperature Preselection SoftkeysReset Softkey

    Reset Panel

    21 - AIR CONDITIONING

    DATE : DEC 1997 Page 1 F21TC10

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    Page 19

    _

    F5M0100GEMetric

  • 8/12/2019 TTM GEN FAM 21

    28/146

    AIR PANELRAM AIR PUSHBUTTON SWITCH

    When the RAM AIR pushbutton is set to ON, on the AIR COND panel, theemergency ram air flaps open provided the ditching pushbutton switch is innormal position on the PRESS panel.

    When it is released out, the emergency ram air inlet flap closes.ON : ON light comes on white. Provided the DITCHING pushbuttonswitch is in normal position:

    - The ram air inlet flap opens- Both outflow valves open at 50% when P is lower than 1 psi.OFF : The ram air inlet flap closes and the outflow valves return totheir normal position.

    PACK 1(2) PUSHBUTTON SWITCHES

    When pack 1 ( or pack 2 ) pushbutton is pressed in, the pack flow controlvalve operates if pneumatic pressure is available. When set to OFF, the packflow control valve is maintained closed electrically.

    ON : The flow control valve opens provided there is no pack overheat,no engine starting sequence, no upstream pressure below minimum, nocorresponding fire pushbutton released out, no passenger/crew dooropen nor ditching selected.

    OFF : The flow control valve closes.FAULT : comes on amber when the flow control valve positiondisagrees with the selected position or in case of pack overheat.

    PACK FLOW SELECTOR

    The PACK FLOW selector serves to select the pack flow.The PACK FLOW selector enables the pack flow setting to be selected in

    accordance with the number of passengers and the ambient conditions.LO : 80% of normal flowNORM : 100%HI : 125% of normal flow.

    ZONE TEMPERATURE SELECTORS

    The COCKPIT and CABIN temperature selectors enable the selection of thedesired ambient temperature in the corresponding zone.

    12 oclock position: 24C

    COLD position: 18CHOT position: 30C

    HOT AIR 1(2) PUSHBUTTON SWITCHES

    When the HOT AIR pushbutton is pressed in, the trim air pressure regulatingvalve opens and pneumatically regulates hot air pressure above the cabinpressure. When set to OFF, the valve is electrically closed.

    ON : The valve regulates hot air pressure.

    OFF : The valve closes, the trim air valves close and the FAULTcircuit is reset.FAULT : Comes on amber when a duct overheat temperature isdetected (88C). FAULT light goes off when the duct temperature

    drops below 70C or OFF is selected .

    21 - AIR CONDITIONING

    DATE : DEC 1997 Page 2 F21TC10

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    Page 20

    _

    F5M0100GEMetric

  • 8/12/2019 TTM GEN FAM 21

    29/146

    21 - AIR CONDITIONING

    DATE : DEC 1997 Page 3 F21TC10

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    Page 21

    _

    F5M0100GEMetric

  • 8/12/2019 TTM GEN FAM 21

    30/146

    P.I.M.CABIN TEMP HARDKEY

    When the CABIN TEMP hardkey is pressed on the Programming andIndicating Module (P.I.M.), the cabin temperature page is displayed. Itprovides the menu for cabin temperature and remote control of the three cabin

    zones.

    The actual temperature is simultaneously represented by a figure and abargraph. The preselected range is centered on the cockpit selectedtemperature and covers 5 degrees celcius (+/-2.5 DEG C).

    The three arrows initially indicate the cockpit selected temperature.The seat row values for each zone depend on the cabin layout selected on the

    Cabin Attendant Module (C.A.M.).As an option, all temperatures can be indicated in degrees fahrenheit (64-86

    DEG F).

    If the actual temperature is lower than 18 DEG C or greater than 30 DEG C,a green arrow is respectively displayed on the left or the right of the bargraph.

    21 - AIR CONDITIONING

    DATE : DEC 1997 Page 4 F21TC10

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    Page 22

    _

    F5M0100GEMetric

  • 8/12/2019 TTM GEN FAM 21

    31/146

    21 - AIR CONDITIONING

    DATE : DEC 1997 Page 5 F21TC10

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    Page 23

    _

    F5M0100GEMetric

  • 8/12/2019 TTM GEN FAM 21

    32/146

    P.I.M.TEMPERATURE PRESELECTION SOFTKEYSThere are two softkeys per zone wich enable the cabin crew to add orsubstract by increments of 0.5 degrees celcius up to a 2.5 degrees celciusrange around the cockpit selected temperature.The arrow indicating this preselected value moves accordingly on the

    temperature bargraph.

    respectively disappear if the upper or lowerlimit is reached.

    RESET SOFTKEYIf any preselection has been applied, the reset command is available and the

    reset indication displayed in white.

    When the reset softkey is pressed in, the three arrows indicating the threepreselected values move back to the cockpit selected temperature.

    The reset indication becomes green and disappears.

    If the cockpit selected temperature is changed, then the three preselectable

    ranges are repositioned on the bargraphs and the preselected values reset.

    21 - AIR CONDITIONING

    DATE : DEC 1997 Page 6 F21TC10

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    Page 24

    _

    F5M0100GEMetric

  • 8/12/2019 TTM GEN FAM 21

    33/146

    21 - AIR CONDITIONING

    DATE : DEC 1997 Page 7 F21TC10

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    Page 25

    _

    F5M0100GEMetric

  • 8/12/2019 TTM GEN FAM 21

    34/146

    RESET PANELA reset control is provided for each controller.Reset is performed by pulling and pushing the corresponding circuit breaker.

    21 - AIR CONDITIONING

    DATE : DEC 1997 Page 8 F21TC10

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    Page 26

    _

    F5M0100GEMetric

  • 8/12/2019 TTM GEN FAM 21

    35/146

    21 - AIR CONDITIONING

    DATE : DEC 1997 Page 9 F21TC10

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    Page 27

    _

    F5M0100GEMetric

  • 8/12/2019 TTM GEN FAM 21

    36/146

    STUDENT NOTES

    21 - AIR CONDITIONING

    DATE : DEC 1997 Page 10 F21TC10

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    Page 28

    _

    F5M0100GEMetric

  • 8/12/2019 TTM GEN FAM 21

    37/146

    TEMPERATURE CONTROL:

    PACK PRESENTATION

    Introduction

    Exchangers / CompressorPlenum ChamberCheck ValveHigh Pressure Water Separation Loop

    Turbine / FanTemperature Control Valve, Ram Air Inlet and Ram AirOutlet FlapsBy Pass Valve

    Anti Icing ValveSensors

    Downstream Check ValveSelf Examination

    21 - AIR CONDITIONING

    DATE : FEB 1998 Page 1 F21TE10

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    Page 29

    _

    F5M0100GEMetric

  • 8/12/2019 TTM GEN FAM 21

    38/146

  • 8/12/2019 TTM GEN FAM 21

    39/146

    21 - AIR CONDITIONING

    DATE : FEB 1998 Page 3 F21TE10

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    Page 31

    _

    F5M0100GEMetric

  • 8/12/2019 TTM GEN FAM 21

    40/146

    ANTI ICING VALVE

    An anti-icing valve prevents ice formation across the condenser by supplyinghot air at the turbine outlet.The anti-ice valve operates according to delta pressures sensed across thecondenser in order to prevent ice build-up at any time.In case of pack controller failure, the anti-icing valve is used also as a

    temperature control valve back-up.Its solenoid is then de-energized and the anti-icing valve pneumaticallyoperates under the control of the Pneumatic Temperature Sensor to maintaina pack discharge temperature of approximately 11C (52F).

    SENSORS

    Pack sensors are used for pack temperature control, monitoring andindicating.

    DOWNSTREAM CHECK VALVE

    A downstream check valve prevents reverse flow back to the pack.

    21 - AIR CONDITIONING

    DATE : FEB 1998 Page 4 F21TE10

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    Page 32

    _

    F5M0100GEMetric

    A330 300 TECHNICAL TRAINING MANUAL

  • 8/12/2019 TTM GEN FAM 21

    41/146

    21 - AIR CONDITIONING

    DATE : FEB 1998 Page 5 F21TE10

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    Page 33

    _

    F5M0100GEMetric

    A330 300 TECHNICAL TRAINING MANUAL

  • 8/12/2019 TTM GEN FAM 21

    42/146

    SELF EXAMINATION

    What is the purpose of the temperature control valve ?

    A - To reduce the air flow to the compressor stage.

    B - To modulate the pack discharge temperature.C - To increase the air flow to the turbine stage.

    What is the main purpose of the anti-icing valve ?

    A - The anti-icing valve prevents ice formation across theprimary heat exchanger.

    B - The anti-icing valve prevents ice formation across the mainheat exchanger.C - The anti-icing valve prevents ice formation across the packcondenser.

    What is the purpose of the ram air flaps ?

    A - To ensure cabin ventilation if both packs fail.B - To provide air to the pack compressor.C - To modulate the main air flow through the heat exchangers.

    What is the purpose of the by-pass valve ?

    A - To by-pass the air cycle machine when it is faulty.

    B - To by-pass the air cycle machine when its associated packcontroller is faulty.C - To modulate the air flow through the air cycle machine.

    What is the purpose of the reheater ?

    A - To condense humidity of air into water particles.B - To revaporise remaining water particles not extracted by thewater extractor.

    C - To reheat air leaving the turbine.

    21 - AIR CONDITIONING

    DATE : FEB 1998 Page 6 F21TE10

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    Page 34

    _

    F5M0100GEMetric

    A330 300 TECHNICAL TRAINING MANUAL

  • 8/12/2019 TTM GEN FAM 21

    43/146

    TEMPERATURE CONTROL :

    ECAM PAGE PRESENTATION

    Pack Flow Control Valve

    Pack Inlet FlowCompressor Outlet TemperatureTemperature Control ValvePack Discharge Temperature

    By-pass ValveEmergency Ram AirBleed UsersHot Air 1 (2)

    Trim Air Pressure Regulating ValveTrim Air Shut Off Valve

    Trim Air ValvesZone Duct Temperature

    Zone TemperatureZone Controller StatusAir Ducts

    21 - AIR CONDITIONING

    DATE : OCT 1997 Page 1 F21TM10

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    Page 35

    _

    F5M0100GEMetric

    A330-300 TECHNICAL TRAINING MANUAL

  • 8/12/2019 TTM GEN FAM 21

    44/146

    PACK FLOW CONTROL VALVE

    The flow control valves indications are normally green.

    PACK INLET FLOW

    The position of the needle represents the actual rate of pack flow.

    COMPRESSOR OUTLET TEMPERATURE

    The compressor outlet temperature indications are normally green. The valuevaries by steps of 2C (4F).

    GREEN

    : Valve not fully closed.

    : The pack airflow data is not available.

    AMBER CROSSES

    : LO = 70% of airflow.

    : HI =130% of airflow.

    The needle can vary from

    62% to 137% of airflow.GREEN NEEDLE

    AMBER

    : Valve fully closed.

    AMBER CROSSES

    : Valve position data not available.

    AMBER

    : The temperature indication exceeds 260C(500F). It becomes green again when thetemperature drops below 180C (356F).

    AMBER

    : The temperature data is not available.

    21 - AIR CONDITIONING

    DATE : OCT 1997 Page 2 F21TM10

    _A330 300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    Page 36

    _

    F5M0100GEMetric

  • 8/12/2019 TTM GEN FAM 21

    45/146

    A330-300 TECHNICAL TRAINING MANUAL

  • 8/12/2019 TTM GEN FAM 21

    46/146

    TEMPERATURE CONTROL VALVE

    The needle position represents the position of the temperature control valve.

    PACK DISCHARGE TEMPERATURE

    The value represents the pack outlet temperature controlled by the pack

    controller. It is normally displayed in green. The value varies by steps of 2C(4F).

    : C (Cold) corresponds to a fully closed position.

    : H (Hot) corresponds to a fully opened position.

    GREEN NEEDLE

    : The TCV position data is not available.

    AMBER CROSSES

    AMBER

    : The temperature indication exceeds 95C (203F). It

    becomes green again when the temperature drops

    below 60C (140F).

    AMBER

    : The temperature data is not available.

    : The TCV is determined faulty.

    AMBER NEEDLE

    21 - AIR CONDITIONING

    DATE : OCT 1997 Page 4 F21TM10

    _

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    Page 38

    _

    F5M0100GEMetric

    A330-300 TECHNICAL TRAINING MANUAL

  • 8/12/2019 TTM GEN FAM 21

    47/146

    21 - AIR CONDITIONING

    DATE : OCT 1997 Page 5 F21TM10

    _

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    Page 39

    _

    F5M0100GEMetric

  • 8/12/2019 TTM GEN FAM 21

    48/146

    21 AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

  • 8/12/2019 TTM GEN FAM 21

    49/146

    21 - AIR CONDITIONING

    DATE : OCT 1997 Page 7 F21TM10

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    Page 41

    _

    F5M0100GEMetric

    21 AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    50/146

    EMERGENCY RAM AIR

    The Ram air valve indications are normally displayed in green.

    BLEED USERS

    GREEN

    : Valve normally closed.

    AMBER VALVE

    GREEN DUCTS

    : Undetermined position, valve in transit.

    GREEN

    : Valve normally open.

    AMBER CROSSES

    : Valve position data not available.

    AMBER VALVE

    GREEN DUCT

    : Valve fully closed and disagrees with command.

    AMBER VALVE

    GREEN DUCTS

    : Valve open on ground or valve position

    open but disagrees with command.

    GREEN

    In normal operation, bleed users are displayed in green

    AMBER

    The two flow control valves and the Ram-air valve are fully closed.

    21 - AIR CONDITIONING

    DATE : OCT 1997 Page 8 F21TM10

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    Page 42

    _

    F5M0100GEMetric

    21 AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    51/146

    21 - AIR CONDITIONING

    DATE : OCT 1997 Page 9 F21TM10

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    Page 43

    _

    F5M0100GEMetric

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    52/146

    HOT AIR 1 (2)

    Hot air color indications give the pack flow control valve positions.

    TRIM AIR PRESSURE REGULATING VALVE

    These indications give the Trim Air Pressure Regulating Valve positions.

    GREEN

    : Respective flow control valve not fully

    closed or valve position data not available

    AMBER

    : Flow control valve fully closed.

    GREEN

    : Valve normally closed.

    GREEN

    : Valve normally open.

    AMBER

    : Valve abnormally closed.

    AMBER

    : Valve abnormally open.

    AMBER CROSSES

    GREEN CIRCLE

    : Position data not available.

    21 - AIR CONDITIONING

    DATE : OCT 1997 Page 10 F21TM10

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    Page 44

    _

    F5M0100GEMetric

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    53/146

    21 AIR CONDITIONING

    DATE : OCT 1997 Page 11 F21TM10

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

    Page 45

    _

    F5M0100GEMetric

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    54/146

    TRIM AIR SHUT OFF VALVE

    These indications give the Trim Air Shut-off Valve position.

    TRIM AIR VALVES

    The position of the needle represents the valve position and consequently thehot air flow.

    GREEN

    : Valve normally closed.

    GREEN

    : Valve normally open.

    AMBER

    : Valve abnormally closed.

    AMBER CROSSES

    : Position data not available.

    : H (Hot), valve fully open.

    : C (Cold), valve fully closed.

    GREEN NEEDLE

    : Valve position data is not available.

    AMBER CROSSES

    21 AIR CONDITIONING

    DATE : OCT 1997 Page 12 F21TM10Page 46

    _

    F5M0100GEMetric

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    55/146

    DATE : OCT 1997 Page 13 F21TM10Page 47

    _

    F5M0100GEMetric

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    56/146

    ZONE DUCT TEMPERATURE

    The zone duct temperature indications are normally displayed in green. The

    temperature varies by steps of 2C (4F).

    ZONE TEMPERATUREThe zone temperature indications are always displayed in green. Thetemperature varies by steps of 1C (2F).

    These indications are also displayed on the ECAM CRUISE page.The temperature varies by steps of 1C (2F).

    A green pulsing flow increase request warning is displayed when the flow is

    insufficient to reach the selected temperature.

    AMBER

    : The temperature indication exceeds 88C

    (190F). It becomes green again when the

    temperature drops below 70C (158F).

    AMBER

    : The temperature data is not available.

    GREEN

    : Temperature normal display.

    AMBER

    : The temperature data is not available.

    : This green pulsing message is displayed

    when the air flow is insufficient to reach

    the selected zone temperature.

    Not displayed otherwise.GREEN

    GREEN

    : Temperature normal display.

    AMBER

    : The temperature data is not available.

    DATE : OCT 1997 Page 14 F21TM10Page 48

    _

    F5M0100GEMetric

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    57/146

    DATE : OCT 1997 Page 15 F21TM10Page 49

    _

    F5M0100GEMetric

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    58/146

    ZONE CONTROLLER STATUS

    The PACK REG indication appears in green when the zone controller isinoperative.

    AIR DUCTS

    The ducts are normally colored in green.

    : The zone controller is inoperative (both

    channels are faulty) or the data related to

    the zone controller state is not available.GREEN

    The air distribution is not yet operative

    (engine starting sequence) or air system

    failure or associated FCV fully closed..

    AMBER

    DATE : OCT 1997 Page 16 F21TM10Page 50

    _

    F5M0100GEMetric

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    59/146

    DATE : OCT 1997 Page 17 F21TM10Page 51

    _

    F5M0100GEMetric

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    60/146

    STUDENT NOTES

    DATE : OCT 1997 Page 18 F21TM10Page 52

    _

    F5M0100GEMetric

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    61/146

    COCKPIT / CABIN VENTILATION :

    SYSTEM PRESENTATION

    COCKPIT/CABIN

    GeneralFiltersClogging Indicators

    Recirculation FansCheck ValvesRecirculation ValvesAir Outlets

    LAVATORY/GALLEY

    General

    Extraction FanDifferential Pressure SwitchSafety SwitchSelf Examination

    DATE : OCT 1997 Page 1 F21CA10Page 53

    _

    F5M0100GEMetric

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    62/146

    COCKPIT/CABIN

    GENERALCabins are ventilated by mixed air from the mixer unit and hot airfrom the trim air valves.

    The cockpit is ventilated with fresh air from pack 1 mainly and hot airfrom its dedicated trim air valve.

    FILTERSFilters are installed at the inlet of the cabin air recirculation circuit.

    CLOGGING INDICATORSThe clogging indicators are differential pressure switches used togenerate maintenance information in case of filter clogging.

    RECIRCULATION FANSTwo recirculation fans feed the mixer unit with air from the cabin.In addition, they are used as blowers for the avionics ventilation.

    The recirculation fans are controlled from the CAB FANS pushbuttonswitch on the overhead panel.The fans automatically stop in case of DITCHING.

    CHECK VALVES

    Check valves are installed to prevent reverse flow when recirculationfans are OFF.

    RECIRCULATION VALVESThe recirculation valves are normally open.

    They close when both packs are OFF to keep the avionics equipmentsufficiently ventilated.

    The signal indicating that both packs are OFF is sent by the zonecontroller.

    AIR OUTLETSConditioned air tapped from the main distribution ducts is sent to the

    individual and fixed air outlets.

    DATE : OCT 1997 Page 2 F21CA10Page 54

    _

    F5M0100GEMetric

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    63/146

    DATE : OCT 1997 Page 3 F21CA10Page 55

    _

    F5M0100GEMetric

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    64/146

    LAVATORY/GALLEY

    GENERALLavatory and galley ventilation air is ducted from the main cabin airdistribution supply.

    Air is discharged overboard by differential pressure or by anExtraction Fan.

    Cabin temperature sensors are ventilated with cabin air drawn by the

    Extraction Fan.

    EXTRACTION FAN

    The Extraction Fan operates on ground when electrical power isavailable and in flight when delta P is lower than 1 psi.

    The Extraction Fan is controlled by the ventilation controller.

    The ground/flight signal comes from Landing Gear Control InterfaceUnit 2 (LGCIU).

    DIFFERENTIAL PRESSURE SWITCHThe Differential Pressure Switch serves to detect when delta P is lowerthan 1 psi for extraction fan operation control.

    SAFETY SWITCHA Safety Switch detects any abnormal low pressure and sends signals

    to the ventilation controller for condition monitoring.

    DATE : OCT 1997 Page 4 F21CA10Page 56

    _

    F5M0100GEMetric

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    65/146

    DATE : OCT 1997 Page 5 F21CA10Page 57

    _

    F5M0100GEMetric

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    66/146

    SELF EXAMINATION

    When does the lavatory and galley extraction fan operate ?

    A - On ground when P is higher than 1 psi and in flight whenP is lower than 1 PSI.B - Always when electrical power is available.

    C - On ground when electrical power is available and in flight

    when P is lower than 1 psi.

    When do the recirculation valves close ?

    A - When both packs are OFF.B - When pack 1 is OFF.C - When pack 2 is OFF.

    DATE : OCT 1997 Page 6 F21CA10Page 58

    _

    F5M0100GEMetric

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    67/146

    COCKPIT / CABIN VENTILATION :

    SYSTEM CONTROLS AND INDICATING

    Cab Fans Pushbutton Switch

    Fans Reset Pushbutton

    Fan Indication

    DATE : OCT 1997 Page 1 F21CB10Page 59

    _

    F5M0100GEMetric

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    68/146

    CAB FANS PUSHBUTTON SWITCH

    The CAB FANS pushbutton switch enables the crew to simultaneously stopboth recirculation fans. When the CAB FANS pushbutton switch is pressedin, both recirculation fans run provided there is no overheat condition.

    Both recirculation fans are switched off.

    FANS RESET PUSHBUTTON

    The Fan Reset pushbutton indicates an overheat of at least one fan controlledby the ventilation controller and enables the crew to reset it.

    There is a recirculation fan overheat.

    When the P/B is pressed, the fan restarts and the fault

    light goes off provided the overheat condition hasdisappeared.

    FAN INDICATION

    The fan indication is not displayed in normal operation or when the fan statedata is not available.

    The respective recirculation fan is faulty, or the CAB

    FANS pushbutton switch is selected OFF or theventilation controller is faulty.

    DATE : OCT 1997 Page 2 F21CB10Page 60

    _

    F5M0100GEMetric

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    69/146

    DATE : OCT 1997 Page 3 F21CB10Page 61

    _

    F5M0100GEMetric

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    70/146

    STUDENT NOTES

    DATE : OCT 1997 Page 4 F21CB10Page 62

    _

    F5M0100GEMetric

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    71/146

    AFT GALLEY AREA HEATING SYSTEM

    PRESENTATION

    General

    Power Supply Logic

    Control And IndicatingThermal Protection

    DATE : APR 1999 Page 1 F21EA01Page 63

    _

    F5M0100GEMetric

    GENERAL

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    72/146

    GENERAL

    The aft galley-area heating system increases the temperature of the air in theaft galley area.The air comes from the cabin air supply area and flows through a heaterlocated in the upper part of the aft galley.

    POWER SUPPLY LOGIC

    The heater is powered by the 115 VAC service bus.The 115 VAC is available only if at least one air conditioning pack operatesand galley power is "ON", provided the cargo loading is not operating.

    CONTROL AND INDICATINGAs soon as all the heater supply initial conditions are fulfilled, the "AVAIL"indication illuminates on the aft GALLEY AREA HEATING panel meaning

    that the heater is available.

    Two temperature settings (low or high) can be selected through two p/bswitches located on the GALLEY AREA HEATING panel.

    The "LOW ON" selection powers one heating element while the "HIGH ON"selection powers the three elements.

    THERMAL PROTECTION

    In case of heater overheat the thermal switch opens. This causes the heatersupply to be interrupted.The "AVAIL" indication on the GALLEY AREA HEATING panel willextinguish as long as the overheat exits.

    DATE : APR 1999 Page 2 F21EA01Page 64

    _

    F5M0100GEMetric

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    73/146

    DATE : APR 1999 Page 3 F21EA01Page 65

    _

    F5M0100GEMetric

    STUDENT NOTES

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    74/146

    STUDENT NOTES

    DATE : APR 1999 Page 4 F21EA01Page 66

    _

    F5M0100GEMetric

  • 8/12/2019 TTM GEN FAM 21

    75/146

    INTERFACEGROUND REFRIGERATION SYSTEM (OPTIONAL)

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    76/146

    INTERFACE

    RECIRCULATION SYSTEM

    The recirculation fans of the cockpit and cabin ventilation system arealso used as blower fans for the avionics equipment ventilation.

    The recirculation fans are controlled, via the ventilation controller,from the VENTILATION panel.

    The recirculation valves are normally open.They close when both packs are OFF to keep the avionics equipment

    sufficiently ventilated.

    The valves are controlled and monitored by the ventilation controller.

    AVIONICS VENTILATION SYSTEM

    GENERAL

    Vent air is supplied either from the recirculation system or from thepacks.Air is extracted by means of an extraction fan.Air is discharged either overboard through the overboard valve or

    under the cargo floor through the underfloor valve.

    When the overboard valve is open, the underfloor valve is closed andvice versa.

    A ground horn sounds in case of abnormal operation on ground.

    The cooling capacity is monitored by two sensors (Cooling EffectDetector and pressure switch).

    All avionics ventilation system components are controlled andmonitored by the Avionics Equipment Ventilation Computer (AEVC).

    The ground refrigeration system cools the air of the avionicsventilation system.The Ground Refrigeration Unit (GRU) is a freon gas closed-cyclerefrigeration system which operates on a compression expansionprinciple. The GRU is designed to meet the new environmental

    requirements.

    It operates when the aircraft is on ground with all engines and bothpacks stopped, ditching not selected, GND COOL pushbutton switch

    on AUTO and the recirculated air temperature higher than 27C.

    Control and monitoring are performed by the Avionics EquipmentVentilation Computer.

    The ground/flight signal comes from LGCIU 1 and 2.The engines 1 and 2 stopped signal comes from the oil low pressureswitches (1 and 2). The ditching signal comes from the PRESS panel.

    When the system operates, the fan runs and the heat accumulated in

    the condenser is extracted through the skin air valve.

    EXTRACTION FAN

    The extraction fan draws the air from the avionics equipment.It is monitored by the Avionics Equipment Ventilation Computer.

    It runs continuously whenever electrical power is available.

    DATE : APR 1999 Page 2 F21VA04Page 68

    _

    F5M0100GEMetric

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    77/146

    DATE : APR 1999 Page 3 F21VA04Page 69

    _

    F5M0100GEMetric

    OVERBOARD VALVE PRESSURE SWITCH

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    78/146

    In AUTO mode, air is extracted through the overboard valve providedthe aircraft is on ground and engines 1 and 2 stopped.

    The overboard valve will receive a signal to close if DITCHING isselected on the PRESS panel.

    Manual OVRD selection on EXTRACT pushbutton switch controlspartial opening of the overboard valve.In flight it will ensure equipment ventilation by differential pressure.

    This manual selection is done in case of low flow detection or avionicssmoke procedure.

    UNDERFLOOR VALVE

    The underfloor valve is closed and the overboard valve is open,provided the EXTRACT pushbutton switch is in AUTO position,

    engines 1 and 2 stopped, and the aircraft on ground.

    In flight, the extracted air is discharged below the forward cargocompartment floor via the underfloor valve, the overboard valve being

    closed.

    If the OVRD position is selected, the underfloor valve closes to allowthe air to be sent overboard via the overboard valve.

    COOLING EFFECT DETECTOR (CED)

    The Cooling Effect Detector provides a warning signal when the

    cooling capacity of the recirculated air is insufficient.

    The Pressure Switch signals a low pressure to the Avionics EquipmentVentilation Computer in order to detect any low flow.

    In case of low flow, the FAULT light on the EXTRACT pushbuttonswitch comes on and an electrical signal is sent to the ECAM and

    ground horn.

    AIR CONDITIONING BAY VENTILATION

    TURBOFAN AND SUPPLY VALVE

    The air conditioning bay is ventilated by external air to preventstructural damage. With the aircraft on ground, the turbofan boosts airinto the ventilation circuit.The turbofan is driven as soon as it receives air from the cross bleed

    duct via the supply valve.

    In flight, the supply valve being closed, ventilation is performed byram air from NACA air inlet.

    When the turbofan is in windmilling configuration, the overflowbypasses the turbofan through the check valve.

    PRESSURE SWITCH

    A pressure switch signals an abnormal ventilation to the AvionicsEquipment Ventilation Computer.

    DATE : APR 1999 Page 4 F21VA04Page 70

    _

    F5M0100GEMetric

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    79/146

    DATE : APR 1999 Page 5 F21VA04Page 71

    _

    F5M0100GEMetric

    SELF EXAMINATION

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    80/146

    What is the position of the avionics ventilation valves on ground,engines 1 and 2 stopped and in AUTO mode ?

    A - Underfloor valve closed - Overboard valve open.B - Underfloor valve open - Overboard valve closed.C - Underfloor valve closed - Overboard valve partially open.

    What is the position of the avionics ventilation valves in flight in AUTOmode ?

    A - Underfloor valve open - Overboard valve closed.B - Underfloor valve closed - Overboard valve open.C - Underfloor valve closed - Overboard valve partially open.

    What is the position of the avionics ventilation valves when OVRD is

    selected on the EXTRACT pushbutton ?

    A - Underfloor valve open - Overboard valve partially open.B - Underfloor valve closed - Overboard valve open.C - Underfloor valve closed - Overboard valve partially open.

    On ground, what is the correct configuration for the air conditioning bayventilation system ?

    A - Supply valve open - Turbofan operating.B - Supply valve closed - Turbofan in windmilling.C - Supply valve open - Turbofan stopped.

    DATE : APR 1999 Page 6 F21VA04Page 72

    _

    F5M0100GEMetric

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    81/146

    AVIONICS / AIR CONDITIONING BAY

    VENTILATION :SYSTEM CONTROLS AND INDICATING

    Extract P/B

    OVBD ValveVent

    DATE : OCT 1997 Page 1 F21VB01Page 73

    _

    F5M0100GEMetric

  • 8/12/2019 TTM GEN FAM 21

    82/146

  • 8/12/2019 TTM GEN FAM 21

    83/146

    STUDENT NOTES

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    84/146

    DATE : OCT 1997 Page 4 F21VB01Page 76

    _

    F5M0100GEMetric

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    85/146

    AVIONICS EQUIPMENT GROUND COOLING :

    SYSTEM CONTROLS AND INDICATING

    Ground Cooling P/B

    Skin ValveGround Cooling Indication

    DATE : NOV 1997 Page 1 F21VO01Page 77

    _

    F5M0100GEMetric

    GROUND COOLING P/B

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    86/146

    The ground cooling system is automatically controlled by the avionicsequipment ventilation computer provided that the GROUND COOLpushbutton switch is set to AUTO.In case of system malfunction, the GROUND COOL pushbutton switch mustbe set to OFF.

    A/C on ground, engines stopped : Skin valve opens.

    Skin valve open and recirculation air temperature >27C (80F): fan andcompressor run.FAULT : in amber : Ground Refrigeration Unit (GRU), fan or valve failure.OFF : in white : the skin valve closes , the fan and the GRU stop.

    DATE : NOV 1997 Page 2 F21VO01Page 78

    _

    F5M0100GEMetric

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    87/146

    DATE : NOV 1997 Page 3 F21VO01Page 79

    _

    F5M0100GEMetric

    SKIN VALVE

    The skin al e position indication is normall green It becomes amber in

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    88/146

    The skin valve position indication is normally green. It becomes amber incase of abnormal position.

    GROUND COOLING INDICATION

    The GROUND COOL indication is normally white. It becomes amber whenthe skin valve position indication is displayed amber or when the groundcooling system is faulty.GND COOL : white : Normal operation or when the ground cooling system

    status is not available.GND COOL : amber : When the skin air valve is displayed amber or whenthe ground cooling system is faulty.

    DATE : NOV 1997 Page 4 F21VO01Page 80

    _

    F5M0100GEMetric

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    89/146

    FORWARD CARGO COMPARTMENT

    VENTILATION / TEMPERATURE CONTROL :SYSTEM PRESENTATION

    General

    Inlet Isolation ValvesTrim Air ValveCold Air Valve

    Outlet Isolation ValveExtraction FanTemp SensorSelf Examination

    DATE : OCT 1997 Page 1 F21FA02Page 81

    _

    F5M0100GEMetric

    GENERAL

    The forward cargo compartment is ventilated by cabin air cooled by cold airf k 2 d h t d b h t i f t i i l ti l 1

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    90/146

    The forward cargo compartment is ventilated by cabin air, cooled by cold airfrom pack 2 and heated by hot air from trim air pressure regulating valve 1.

    DATE : OCT 1997 Page 2 F21FA02Page 82

    _

    F5M0100GEMetric

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    91/146

    DATE : OCT 1997 Page 3 F21FA02Page 83

    _

    F5M0100GEMetric

  • 8/12/2019 TTM GEN FAM 21

    92/146

  • 8/12/2019 TTM GEN FAM 21

    93/146

    SELF EXAMINATION

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    94/146

    What is the cold air source for cargo cooling ?

    A - Pack 1.

    B - Pack 2.C - Mixer unit.

    When do the isolation valves close ?

    A - In case of Forward cargo smoke warning.B - In case of extraction fan failed.

    C - In case of both packs failed.

    Which valve closes in case of duct overheat detection ?

    A - Outlet isolation valve.

    B - Cold air valve.C - Cargo trim air valve.

    DATE : OCT 1997 Page 6 F21FA02Page 86

    _

    F5M0100GEMetric

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    95/146

    FORWARD CARGO COMPARTMENT

    VENTILATION / TEMPERATURE CONTROL :SYSTEM CONTROLS AND INDICATING

    Isolation Valves P/BCooling SelectorTemperature SelectorFan Reset P/B

    Trim Air ValveCold AirCold Air ValveDuct Temperature

    Compartment Temperature

    DATE : MAY 1999 Page 1 F21FB10Page 87

    _

    F5M0100GEMetric

    As these systems are optional, the indications concerning the FWD cargocompartment temperature control system are displayed on the ECAM CONDand CRUISE pages only if the option is fitted on the aircraft and the

    ISOLATION VALVES P/B

    When the isolation valves pushbutton switch is pressed in, theisolation valves open and the extraction fan runs provided there is no

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    96/146

    ventilation controller pinprogrammed.

    These indications are displayed on ECAM only if the BULK CARGO

    HEATING system is installed.

    smoke detection in the FWD cargo compartment.

    FAULT comes on associated with an ECAM caution when

    either the inlet or outlet isolation valve is not in agreement withthe selected position.

    The pushbutton is released out. The valves close and the

    extraction fan stops.

    COOLING SELECTOR

    The COOLING selector controls the cold air valve via the ventilationcontroller to adjust the quantity of cold air supplied by the mixer unit.The COOLING selector has three positions.

    Cold air valve partially open.

    Cold air valvefully closed.

    Cold air valvefully open.

    DATE : MAY 1999 Page 2 F21FB10Page 88

    _

    F5M0100GEMetric

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    97/146

    DATE : MAY 1999 Page 3 F21FB10Page 89

    _

    F5M0100GEMetric

    TEMPERATURE SELECTOR

    The forward cargo compartment temperature can be adjusted with thetemperature rotary selector

    TRIM AIR VALVE

    The forward cargo trim air valve indication is normally displayed ingreen on the ECAM COND page.

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    98/146

    temperature rotary selector.

    The temperature regulation is performed by changing the FWD cargoTrim Air Valve position.

    FAN RESET P/B

    The Fan Reset pushbutton indicates an overheat of at least one fan

    controlled by the ventilation controller and enables the crew to resetit.

    There is an extraction fan overheat.

    When the P/B is pressed, the fan restarts and the fault light goesoff provided the overheat condition has disappeared.

    Normal operation.C (COLD) = Valve closed.

    H (HOT) = Valve open.

    The trim air valve has failed.

    The trim air valve position data is not available.

    COLD AIR

    The cold air duct indication is normally displayed in green on theECAM COND page.

    The duct is green when the two flow control valves are notfully closed or when their position is not available.

    It becomes amber when one of the two flow control valves arefully closed.

    DATE : MAY 1999 Page 4 F21FB10Page 90

    _

    F5M0100GEMetric

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    99/146

    DATE : MAY 1999 Page 5 F21FB10Page 91

    _

    F5M0100GEMetric

    COLD AIR VALVE

    The cold air valve indication is normally displayed in green on theECAM COND page.

    COMPARTMENT TEMPERATURE

    The forward cargo compartment temperature is always displayed ingreen on the ECAM COND page.

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    100/146

    Valve partially open.

    Valve fully closed.

    Valve fully open.

    Valve abnormal fully closed.

    Valve abnormally fully open.

    Valve abnormally partially open or in transit position.

    Valve position data not available.

    DUCT TEMPERATUREThe forward cargo duct temperature is normally displayed in green onthe ECAM COND page.

    UDTS = Upper Duct Temp. SensorLDTS = Lower Duct Temp. Sensor

    The duct temperature is lower than 88C (190F).

    The duct temperature is greater than 88C (190F).

    The duct temperature data is not available.

    CTS = Compartment Temp. Sensor

    Normal configuration.Temperature varies by steps of 1C (2F).

    The FWD cargo compartment temperature data is not available.

    The FWD cargo compartment temperature is also displayed in greenon the ECAM CRUISE page.

    Normal configuration.Temperature varies by steps of 1C (2F).

    The FWD cargo compartment temperature data is not available.

    DATE : MAY 1999 Page 6 F21FB10Page 92

    _

    F5M0100GEMetric

    AFT CARGO COMPARTMENT VENTILATION :

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    101/146

    AFT CARGO COMPARTMENT VENTILATION :

    SYSTEM PRESENTATION

    General

    Inlet Isolation ValvesExtraction Fan

    Outlet Isolation ValveSelf Examination

    DATE : OCT 1997 Page 1 F21AA02Page 93

    _

    F5M0100GEMetric

    GENERAL

    The aft cargo compartment is ventilated with cabin air.

    INLET ISOLATION VALVES

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    102/146

    INLET ISOLATION VALVES

    The inlet isolation valves allow cabin air, from openings in the cabin floor,

    to enter the compartment.Control is achieved, via the ventilation controller, by the ISOL VALVESpushbutton switch.

    To isolate the cargo compartment, they close if DITCHING is selected or if

    smoke is detected in the AFT or Bulk cargo compartment.

    EXTRACTION FAN

    The extraction fan extracts the air from the cargo compartment.

    The extraction fan operates provided at least one inlet isolation valve is open

    and the outlet isolation valve is open.It stops if smoke is detected in the AFT or Bulk cargo compartment.

    OUTLET ISOLATION VALVE

    The outlet isolation valve allows the air to be ducted overboard through theAFT outflow valve.Control is achieved, via the ventilation controller, by the ISOL VALVES

    pushbutton switch.

    To isolate the cargo compartment, it closes if DITCHING is selected or ifsmoke is detected in the AFT or Bulk cargo compartment.

    DATE : OCT 1997 Page 2 F21AA02Page 94

    _

    F5M0100GEMetric

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    103/146

    DATE : OCT 1997 Page 3 F21AA02Page 95

    _

    F5M0100GEMetric

    SELF EXAMINATION

    When do the isolation valves close ?

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    104/146

    A - In case of AFT cargo smoke warning.

    B - In case of extraction fan failed.C - In case of both packs OFF.

    DATE : OCT 1997 Page 4 F21AA02Page 96

    _

    F5M0100GEMetric

  • 8/12/2019 TTM GEN FAM 21

    105/146

    ISOLATION VALVES P/B

    When the isolation valve pushbutton switch is pressed, the isolation valves

    open and the extraction fan runs provided there is no smoke detection in theaft cargo compartment.

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    106/146

    FAULT (in amber) : comes on associated with ECAM caution when either

    inlet or outlet valve is not in agreement with the selected position.

    OFF (in white) : the isolation valves pushbutton switch released out, thevalves close and the extraction fan stops.

    FANS RESET P/B

    The FAN RESET pushbutton switch indicates an overheat of at least one fanof the air conditioning system and enables the crew to reset it.

    If there is a fan overheat, a FAULT light (in amber) on the OVHT CONDFANS RESET pushbutton switch comes on and the extraction fan stops.When this reset pushbutton switch is pressed, the extraction fan is reset bymeans of the ventilation controller and the fault light goes off.

    DATE : DEC 1997 Page 2 F21AB02Page 98

    _

    F5M0100GEMetric

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    107/146

    DATE : DEC 1997 Page 3 F21AB02Page 99

    _

    F5M0100GEMetric

    STUDENT NOTES :

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    108/146

    DATE : DEC 1997 Page 4 F21AB02Page 100

    _

    F5M0100GEMetric

    BULK CARGO COMPARTMENT

    VENTILATION / HEATING :

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    109/146

    VENTILATION / HEATING :SYSTEM PRESENTATION

    GeneralInlet Isolation Valve

    Extraction FanOutlet Isolation Valve

    Fan Heater (Optional)Duct and Compartment Temperature Sensors (Optional)Self Examination

    DATE : OCT 1997 Page 1 F21BA10Page 101

    _

    F5M0100GEMetri

    c

    GENERAL

    The bulk cargo compartment is ventilated with cabin air by means of an

    extraction fan. An optional heating system may be fitted on the aircraft.Heating is then performed by an electrical fan heater.

    INLET ISOLATION VALVE

    FAN HEATER (OPTIONAL)

    The optional fan heater is controlled by the Ventilation Controller according

    to the cockpit panel selection. It operates provided the inlet and the outletisolation valves are open.It automatically stops in case of Bulk cargo door open (PSCU), smoke

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    110/146

    INLET ISOLATION VALVE

    The inlet isolation valve allows cabin air to enter the Bulk cargo compartmentthrough an elbow duct . Control is achieved, via the ventilation controller, bythe ISOL VALVES pushbutton switch.To isolate the cargo compartment, it closes if DITCHING is selected or if

    smoke is detected in the Bulk or AFT cargo compartment.

    EXTRACTION FAN

    The extraction fan extracts the compartment air.

    The extraction fan operates provided the isolation valves are open.It stops if smoke is detected in the Bulk or AFT cargo compartment.

    OUTLET ISOLATION VALVE

    The outlet isolation valve allows air to be sent overboard through the AFToutflow valve. Control is achieved, via the ventilation controller, by the ISOLVALVES pushbutton switch.

    To isolate the cargo compartment, it closes if ditching is selected or if smokeis detected in the Bulk or AFT cargo compartment.

    detected in the AFT or Bulk cargo compartment (SDCU) or duct or fan

    overheat detection.

    DUCT AND COMPARTMENT TEMPERATURE SENSORS

    (OPTIONAL)

    If the optional heating system is fitted on the aircraft, temperature sensors are

    installed for temperature control and duct temperature overheat detection.

    DATE : OCT 1997 Page 2 F21BA10Page 102

    _

    F5M0100GEMetric

  • 8/12/2019 TTM GEN FAM 21

    111/146

    SELF EXAMINATION

    When do the isolation valves close ?

    A If B lk k i d t t d

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    112/146

    A - If Bulk cargo smoke is detected.

    B - If the extraction fan fails.C - In case of both packs OFF.

    When does the optional fan heater automatically stop ?

    A - When the Bulk cargo door is open.B - When the AFT outflow valve is open.

    C - When a passenger door is open.

    DATE : OCT 1997 Page 4 F21BA10Page 104

    _

    F5M0100GEMetric

    BULK CARGO COMPARTMENT

    VENTILATION / HEATING :

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    113/146

    SYSTEM CONTROLS AND INDICATING

    Isol Valves PushbuttonFans Reset Pushbutton

    Heating P/BTemperature Selector

    Fan Heater IndicationDuct TemperatureZone Temperature

    DATE : OCT 1997 Page 1 F21BB10Page 105

    _

    F5M0100GEMetric

    The indications concerning the bulk cargo compartment temperature controlsystem are displayed on the ECAM COND and CRUISE pages only if the

    option is fitted on the aircraft and the ventilation controller pinprogrammed.

    These indications are displayed on ECAM only if the FWD CARGO TEMPCONTROL is installed

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    114/146

    CONTROL is installed.

    DATE : OCT 1997 Page 2 F21BB10Page 106

    _

    F5M0100GEMetric

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    115/146

    DATE : OCT 1997 Page 3 F21BB10Page 107

    _

    F5M0100GEMetr

    ic

    ISOL VALVES PUSHBUTTON

    When the isolation valves pushbutton switch is pressed in, the isolation

    valves open and the extraction fan runs provided there is no smoke detectionin the bulk cargo compartment.

    HEATING P/B

    When the heating pushbutton switch is pressed in, the fan heater is activated

    provided the isolation valves are open.

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    116/146

    FAULT comes on associated with an ECAM cautionwhen either the inlet or outlet isolation valve is notin agreement with the selected position.

    The pushbutton is released out. The valves close andthe extraction fan stops.

    FANS RESET PUSHBUTTON

    The Fan Reset pushbutton indicates an overheat of at least one fan controlled

    by the ventilation controller and enables the crew to reset it.

    There is an extraction fan or fan heater fan partoverheat.

    When the P/B is pressed, the fan restarts and the faultlight goes off provided the overheat condition hasdisappeared.

    The duct temperature is greater than 88C(190F). The overheat condition can be resetprovided the duct temperature is lower than70C (158F).

    The heating pushbutton is released out and thefan heater stopped.

    TEMPERATURE SELECTOR

    The bulk cargo compartment temperature can be adjusted with the

    temperature rotary selector.

    The temperature regulation is performed by changing

    the fan heater power supply controlled by theventilator controller.

    DATE : OCT 1997 Page 4 F21BB10Page 108

    _

    F5M0100GEMetr

    ic

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    117/146

    DATE : OCT 1997 Page 5 F21BB10Page 109

    _

    F5M0100GEMetr

    ic

    FAN HEATER INDICATION

    The arrow representing the bulk cargo fan heater performance is normally

    displayed in green on the ECAM COND page.

    C (COLD) = minimum performance.H (HOT) = maximum performance.

    ZONE TEMPERATURE

    The bulk cargo compartment temperature is always displayed in green on the

    ECAM COND page.

    Normal configuration. Temperature varies by steps

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    118/146

    The fan heater has failed.

    The fan heater performance data is not available.

    DUCT TEMPERATURE

    The bulk cargo duct temperature is normally displayed in green on the ECAM

    COND page.

    The duct temperature is lower than 88C (190F).

    The duct temperature is greater than 88C (190F).

    The duct temperature data is not available.

    of 1C (2F).

    The bulk cargo compartment temperature data is notavailable.

    The bulk cargo compartment temperature is also displayed in green on the

    ECAM CRUISE page.

    Normal configuration. Temperature varies by steps

    of 1C (2F).

    The bulk cargo compartment temperature data is not

    available.

    DATE : OCT 1997 Page 6 F21BB10Page 110

    _

    F5M0100GEMetric

    PRESSURIZATION :

    SYSTEM DESIGN PHILOSOPHY

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    119/146

    General

    Design Philosophy

    DATE : DEC 1997 Page 1 F21PA02Page 111

    _

    F5M0100GEMetric

    GENERAL

    The pressurization system ensures a cabin altitude safe and compatible with

    crew and passenger comfort.Pressurization is performed by controlling the amount of air dischargedoverboard through two outflow valves.

    DESIGN PHILOSOPHY

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    120/146

    DESIGN PHILOSOPHY

    The system has two identical and independent automatic controllers.Only one controller operates at a time, the other is in active stand-by.

    In normal condition, the system operation is fully automatic.The operation of the automatic cabin pressure control depends onpre-programmed control laws and information from the ADIRUs.The automatic cabin pressure control is achieved from internal schedules, or

    external schedules if the FMGES inputs are available, such as top of climb.

    The CABIN PRESS panel enables manual cabin pressure control in case offailure of both automatic systems. The FWD and AFT valves may be

    simultaneously or independently manually controlled.

    A mixed mode is available mainly in case of cabin compartment smoke

    evacuation. In mixed mode, one outflow valve may be manually controlledwhereas the other one remains under automatic control (active cabin pressurecontroller).

    Two safety valves are installed on the aft pressure bulkhead to prevent

    excessive positive or negative differential pressure.Due to the large volume of the fuselage, a negative pressure relief valveassists the safety valves to prevent negative differential pressure.

    DATE : DEC 1997 Page 2 F21PA02Page 112

    _

    F5M0100GEMetric

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    121/146

    DATE : DEC 1997 Page 3 F21PA02Page 113

    _

    F5M0100GEMetric

    SELF EXAMINATION

    What is the number of outflow valves, safety valves and negative pressurerelief valves ?

    A - One outflow valve two safety valves and one negative

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    122/146

    A One outflow valve, two safety valves and one negativepressure relief valve.B - Two outflow valves, two safety valves and one negativepressure relief valve.

    C - Two outflow valves, one safety valve and one negativepressure relief valve.

    What is the purpose of the negative pressure relief valve ?

    A - To avoid over-temperature.B - To prevent negative differential pressure.

    C - To prevent positive differential pressure.

    What is the purpose of the safety valves ?

    A - To avoid negative differential pressure.B - To replace the outflow valves.C - To prevent excessive differential pressure.

    DATE : DEC 1997 Page 4 F21PA02Page 114

    _

    F5M0100GEMetric

    PRESSURIZATION :

    SYSTEM CONTROLS AND INDICATING

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    123/146

    Active Valve Selector

    MAN V/S Toggle SwitchMODE SEL P/B SwitchLanding Field Elevation SelectorDitching P/B Switch

    CPC Reset Switches

    DATE : DEC 1997 Page 1 F21PC10Page 115

    _

    F5M0100GEMet

    ric

  • 8/12/2019 TTM GEN FAM 21

    124/146

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    125/146

    DATE : DEC 1997 Page 3 F21PC10Page 117

    _

    F5M0100GEMetric

    STUDENT NOTES

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    126/146

    DATE : DEC 1997 Page 4 F21PC10Page 118

    _

    F5M0100GEMetric

    PRESSURIZATION: FLIGHT PROFILE

    Ground

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    127/146

    GroundTake-off

    ClimbCruiseDescent

    Ground

    DATE : MAR 1999 Page 1 F21PF09Page 119

    _

    F5M0100GEMetric

  • 8/12/2019 TTM GEN FAM 21

    128/146

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    129/146

    DATE : MAR 1999 Page 3 F21PF09Page 121

    _

    F5M0100GEMe

    tric

  • 8/12/2019 TTM GEN FAM 21

    130/146

    SELF EXAMINATION

    What is the position of the outflow valves in ground mode?

    A - Half open.

    B - Fully closed.C - Fully open.

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    131/146

    y p

    DATE : MAR 1999 Page 5 F21PF09Page 123

    _

    F5M0100GEMe

    tric

    STUDENT NOTES

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    132/146

    DATE : MAR 1999 Page 6 F21PF09Page 124

    _

    F5M0100GEMe

    tric

    PRESSURIZATION:

    ECAM PAGE PRESENTATION

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    133/146

    Packs

    Outflow ValvesSafety ValvesActive System

    ManLFE Selection ModeLFE Value

    Cabin PCabin V/SCabin Altitude

    DATE : DEC 1997 Page 1 F21PG10Page 125

    _

    F5M0100GEMe

    tric

    OUTFLOW VALVES

    The Outflow Valve indication gives the respective outflow valve position.

    The needle is normally green and the FWD and AFT indications white.

    : The valve is opened more than 95% during flight or

    it is determined faulty (only in auto press mode).

    ECAM CAB PRESS PAGE

    WHITE LETTERS

    GREEN NEEDLE

    : These indications are displayed on ECAM

    only if the optional ground cooling system isfitted on the aicraft.

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    134/146

    PACKS

    The Pack indication gives the respective flow control valve status.

    ECAM CRUISE PAGE

    GREEN LETTERS

    AMBER TRIANGLE

    AND LETTERS

    : The respective flow control valve is fully closed.

    GREEN TRIANGLE

    :The respective flow control valve is not fully closed.

    AMBER CROSSES

    WHITE LETTERS

    : The respective flow control valve

    position data is not available.

    AMBER LETTERS

    AND NEEDLE

    WHITE LETTERS

    AMBER CROSSES

    : The valve position data is not available.

    : These indications are displayed on ECAM

    only if the optional FWD and BULK cargo

    temperature control systems are fitted on the

    aircraft.

    DATE : DEC 1997 Page 2 F21PG10Page 126

    _

    F5M0100GEMe

    tric

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    135/146

    DATE : DEC 1997 Page 3 F21PG10Page 127

    _

    F5M0100GEMe

    tric

    SAFETY VALVES

    The safety valve indication gives the safety valve status. The position signals

    are provided to the SDAC by a discrete signal from the valves sensor.

    ACTIVE SYSTEM

    It indicates which system is active and what is the system status.

    Only one system is active at a time.When both systems are faulty, the "FAULT" light on the MODESEL pushbutton comes on.

    : System 1 is active and not faulty.

    : Both safety valves are fully closed.

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    136/146

    MAN

    The MAN indication appears in green above the outflow valve indication

    when its corresponding valve is manually controlled.MAN indication is not displayed otherwise.

    AMBER

    GREEN

    AMBER

    : System 1 is faulty.

    : System status data is not available.

    GREEN

    : The corresponding outflow valve is manually controlled.

    WHITE LETTERS

    AMBER CROSSES

    : Both safety valves position data are not available

    or one is not available and the other valve is closed.

    AMBER LETTERS

    AND NEEDLE

    : At least one of the safety valves is not fully closed.

    GREEN NEEDLE

    WHITE LETTERS

    DATE : DEC 1997 Page 4 F21PG10Page 128

    _

    F5M0100GEMe

    tric

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    137/146

    DATE : DEC 1997 Page 5 F21PG10Page 129

    _

    F5M0100GEMe

    tric

    LFE SELECTION MODE

    It indicates if the Landing Field Elevation data comes either from the FMGESor the landing elevation selector. It also provides the LFE source status.Nothing is displayed when the LDG ELEV selector is completely faulty orduring manual pressure regulation.The LFE selection indication is also displayed on the CRUISE ECAM page.

    LFE VALUE

    The Landing Field Elevation value is provided by the FMGES in normalcondition.Nothing is displayed in manual pressure regulation.The LFE value indication is also displayed on the CRUISE ECAM page.

    : LFE data is available.

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    138/146

    GREEN

    : LFE data from FMGES is valid and

    LDG ELEV selector set to AUTO.

    AMBER

    : LFE data from FMGES invalid and

    LDG ELEV selector set to AUTO.

    GREEN

    : LDG ELEV selector set to a value

    AMBER

    : At least one parameter from CPCs

    automatic part is not available.

    GREEN

    (From FMGES or LDG ELEV selector).

    AMBER

    : LFE data is not available.

    GREEN ZERO

    AND CYAN

    LETTERS

    : LFE from FMGES is invalid, (AUTO in amber)

    or LDG ELEV selector is completely faulty.

    DATE : DEC 1997 Page 6 F21PG10Page 130

    _

    F5M0100GEMetric

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    139/146

    DATE : DEC 1997 Page 7 F21PG10Page 131

    _

    F5M0100GEMetric

    CABIN PThe needle and the cabin differential pressure value are normally displayed

    in green. The

    P value can vary from -9.9 to 31.9 by steps of 0.1 PSI, but

    the needle can only vary from -0.5 to 10.5 PSI.

    The cabin differential pressure is also displayed on the CRUISE ECAM page.

    : -0.2 P8.85 PSIDuring final approach the P value and the needle

    : -0.2 P 8.85 PSIDuring final approach, the P value and theneedle pulse in green if 1.5 < P < 8.85 PSI.

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    140/146

    GREEN NEEDLE

    During final approach, the P value and the needlepulse in green if 1.5 8.85 PSI.

    AMBER NEEDLE

    AND VALUE

    : P data is not available.

    AMBER

    CROSSES

    GREEN The pulsing stops when the P drops below 1 PSI.

    AMBER

    : P < -0.2 PSI orP > 8.85 PSI.

    AMBER

    :P data is not available.

    DATE : DEC 1997 Page 8 F21PG10Page 132

    _

    F5M0100GEMetric

  • 8/12/2019 TTM GEN FAM 21

    141/146

    CABIN V/S

    on CAB PRESS ECAM page and CRUISE ECAM page during manual

    press regulation

    The needle and the cabin vertical speed value are normally displayed ingreen. The CAB V/S value can vary from -6350 to 6350 by steps of 50 ft/mn.The needle can only vary from -2250 to 2250 ft/mn. The needle disappears

    and the cabin vertical speed value is replaced by amber crosses when thecabin vertical speed data is not available.

    on DOOR/OXY ECAM page and CRUISE ECAM page during autopress regulation

    GREEN

    : 25 CAB V/S 1800 ft/mn.It pulses green when CAB V/S > 1800 ft/mn.

    It stops pulsing when the CAB V/S value

    drops below 1600 ft/mn.

    1800 CAB V/S 25 f /

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    142/146

    Nothing is displayed when -25 < CAB V/S < 25 ft/mn or the CAB V/S datais not available.

    The cabin vertical speed value is normally displayed in green. It can varyfrom 0 to 6350 by steps of 50 ft/mn.

    The cabin vertical speed indication on the DOOR/OXY ECAM page is

    displayed in flight from lift up to touch down only.

    GREEN NEEDLE

    : The CAB V/S value and the needle pulse in green if

    CAB V/S < -1800 ft/mn or CAB V/S > 1800 ft/mn.

    The pulsing stops when the value drops below

    1600 ft/mn or goes above -1600 ft/mn.

    AMBER

    CROSSES

    : CAB V/S data is not available

    GREEN

    : -1800 CAB V/S -25 ft/mn.It pulses green when CAB V/S < -1800 ft/mn.

    It stops pulsing when the CAB V/S value

    goes above -1600 ft/mn.

    GREEN

    : The CAB V/S value pulses in green when

    CAB V/S < -1800 ft/mn or CAB V/S > 1800 ft/mn.

    It stops pulsing when the value drops

    below 1600 ft/mn or goes above -1600 ft/mn.

    AMBER: CAB V/S data is not available.

    DATE : DEC 1997 Page 10 F21PG10Page 134

    _

    F5M0100GEMetric

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    143/146

    DATE : DEC 1997 Page 11 F21PG10Page 135

    _

    F5M0100GEM

    etric

  • 8/12/2019 TTM GEN FAM 21

    144/146

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    145/146

    DATE : DEC 1997 Page 13 F21PG10Page 137

    _

    F5M0100GEM

    etric

    STUDENT NOTES

    21 - AIR CONDITIONING

    _A330-300 TECHNICAL TRAINING MANUAL

    21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE

  • 8/12/2019 TTM GEN FAM 21

    146/146

    DATE : DEC 1997 Page 14 F21PG10Page 138