A330-300TECHNICAL TRAINING MANUAL
GENERAL FAMILIARIZATION COURSE
21 AIR CONDITIONING
GE Metric
8/12/2019 TTM GEN FAM 21
2/146
8/12/2019 TTM GEN FAM 21
3/146
This document must be used
for training purpose only.
Under no circumstances
should this document be used as a reference.
All rights reserved.
No part of this manual may be reproduced in any form,
by photostat, microfilm, retrieval system, or any other means,
without the prior written permission of Airbus Industrie.
8/12/2019 TTM GEN FAM 21
4/146
8/12/2019 TTM GEN FAM 21
5/146
** System Presentation (1) 1..................................
System Controls and Indicating - General (1) 7...........................
TEMPERATURE CONTROL
** System Design Philosophy (1) 15..............................
** System Controls and Indicating (1) 19............................
** Pack Presentation (1) 29.................................
** ECAM Page Presentation (1) 35..............................
COCKPIT/CABIN VENTILATION
** System Presentation (1) 53................................
** System Controls and Indicating (1) 59............................
AFT GALLEY HEATING
** System Presentation (1) 63................................
AVIONICS/AIR CONDITIONING BAY VENTILATION
** System Presentation (1) 67................................
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
F5M0100GEMetric
_
F5M0100 TABLE OF CONTENTS
DATE : JUN 1999 Page i F5M0121
8/12/2019 TTM GEN FAM 21
6/146
** System Controls and Indicating (1) 73............................
** Avncs Eqpt Gnd Cooling Sys Ctl & Indicating (1 77......................
FWD CARGO COMPT VENT/TEMP CONTROL
** System Presentation (1) 81................................
** System Controls and Indicating (1) 87............................
AFT CARGO COMPARTMENT VENTILATION
System Presentation (1) 93.................................
System Controls and Indicating (1) 97.............................
BULK CARGO COMP VENTILATION/HEATING
** System Presentation (1) 101...............................
** System Controls and Indicating (1) 105...........................
PRESSURIZATION
System Design Philosophy (1) 111..............................
** System Controls and Indicating (1) 115...........................
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
F5M0100GEMetric
_
F5M0100 TABLE OF CONTENTS
DATE : JUN 1999 Page ii F5M0121
8/12/2019 TTM GEN FAM 21
7/146
8/12/2019 TTM GEN FAM 21
8/146
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
F5M0100GEMetric
_
F5M0100 TABLE OF CONTENTS
DATE : JUN 1999 Page iv F5M0121
THIS PAGE INTENTIONALLY LEFT BLANK
8/12/2019 TTM GEN FAM 21
9/146
SYSTEM PRESENTATION
IntroductionPresentation
21 - AIR CONDITIONING
DATE : SEP 1996 Page 1 F21G010
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
Page 1
_
F5M0100GEMetric
8/12/2019 TTM GEN FAM 21
10/146
8/12/2019 TTM GEN FAM 21
11/146
21 - AIR CONDITIONING
DATE : SEP 1996 Page 3 F21G010
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
Page 3
_
F5M0100GEMetric
8/12/2019 TTM GEN FAM 21
12/146
PRESENTATION
Bleed air coming from pneumatic system is controlled in flow before
reaching two air conditioning packs which ensure basic temperatureregulation.Air delivered by the packs is mixed with recirculated air from the cabin zoneswhich is also used for avionics ventilation purpose.
Fine temperature adjustment of air distributed in the pressurized zones isobtained by controlling the amount of hot air added to the air coming fromthe mixer unit.
Correct pressurization is obtained by controlling the conditioned air dischargethrough two outflow valves.
21 - AIR CONDITIONING
DATE : SEP 1996 Page 4 F21G010
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
Page 4
_
F5M0100GEMetric
8/12/2019 TTM GEN FAM 21
13/146
21 - AIR CONDITIONING
DATE : SEP 1996 Page 5 F21G010
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
Page 5
_
F5M0100GEMetric
8/12/2019 TTM GEN FAM 21
14/146
STUDENT NOTES
21 - AIR CONDITIONING
DATE : SEP 1996 Page 6 F21G010
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
Page 6
_
F5M0100GEMetric
8/12/2019 TTM GEN FAM 21
15/146
SYSTEM CONTROLS AND INDICATING -
GENERAL
Overhead Panel
Main Instrument PanelForward Attendant Panel
21 - AIR CONDITIONING
DATE : APR 1999 Page 1 F21G210
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
Page 7
_
F5M0100GEMetric
8/12/2019 TTM GEN FAM 21
16/146
OVERHEAD PANELThe air conditioning system controls are located on the overhead panel.
21 - AIR CONDITIONING
DATE : APR 1999 Page 2 F21G210
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
Page 8
_
F5M0100GEMetric
8/12/2019 TTM GEN FAM 21
17/146
21 - AIR CONDITIONING
DATE : APR 1999 Page 3 F21G210
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
Page 9
_
F5M0100GEMetric
8/12/2019 TTM GEN FAM 21
18/146
MAIN INSTRUMENT PANELThe air conditioning system can be monitored on the ECAM system display.System information is shown on the following pages :
- BLEED page : pack and emergency ram air.- AIR COND page : temperature control, cabin ventilation, cargoventilation, cooling and heating (optional).
- PRESS page : pressurization and avionics ventilation.- CRUISE page : zone temperature and main pressurization systemparameters.
21 - AIR CONDITIONING
DATE : APR 1999 Page 4 F21G210
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
Page 10
_
F5M0100GEMetric
8/12/2019 TTM GEN FAM 21
19/146
21 - AIR CONDITIONING
DATE : APR 1999 Page 5 F21G210
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
Page 11
_
F5M0100GEMetric
8/12/2019 TTM GEN FAM 21
20/146
FORWARD ATTENDANT PANELAt the forward attendant station, the Programming and Indication Moduleallows cabin crew to slightly adjust the temperature regulation in the threecabin zones.
21 - AIR CONDITIONING
DATE : APR 1999 Page 6 F21G210
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
Page 12
_
F5M0100GEMetric
8/12/2019 TTM GEN FAM 21
21/146
21 - AIR CONDITIONING
DATE : APR 1999 Page 7 F21G210
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
Page 13
_
F5M0100GEMetric
8/12/2019 TTM GEN FAM 21
22/146
STUDENT NOTES
21 - AIR CONDITIONING
DATE : APR 1999 Page 8 F21G210
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
Page 14
_
F5M0100GEMetric
8/12/2019 TTM GEN FAM 21
23/146
TEMPERATURE CONTROL:
SYSTEM DESIGN PHILOSOPHY
Basic Principle
Pack ControllersZone ControllerSelf Examination
21 - AIR CONDITIONING
DATE : DEC 1997 Page 1 F21TA02
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
Page 15
_
F5M0100GEMetric
8/12/2019 TTM GEN FAM 21
24/146
BASIC PRINCIPLEAir flow is regulated by two flow control valves. Two packs provide air basictemperature regulation.Both packs provide air at the same temperature.Trim air pressure regulating valves maintain the downstream pressure abovethe cabin pressure allowing hot air and cold air to be mixed.
Trim air valves optimize the temperature by adding hot air to pack air supply,when necessary.A part of cabin air is recirculated to decrease air supply demand.
PACK CONTROLLERS
Each Pack Controller provides:- basic temperature regulation of its associated pack in accordancewith the demand from the zone controller.
- and flow control setting and monitoring.
ZONE CONTROLLERThe Zone Controller provides:
- A basic temperature regulation signal elaboration which is the lowestdemanded zone temperature.- An optimized temperature control which is the demandedtemperature on the control panel.
- An optimized flow control demand.Optimized temperature is provided by control of the trim air valves.In case of cooling demand not satisfied due to low air flow, the zone
controller sends a signal to the EIVMU or ECB in order to provide necessaryflow to the packs.EIVMU : Engine Interface Vibration and Monitoring Unit.ECB : Electronic Control Box (APU).If the selected temperature cannot be maintained, the bleed monitoring
computer receives a signal in order to control the bleed air deliveredtemperature, at a decreased level.The bleed air temperature is reduced from 200C to 150C. This mode isinhibited if the wing anti-ice system is in operation.
21 - AIR CONDITIONING
DATE : DEC 1997 Page 2 F21TA02
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
Page 16
_
F5M0100GEMetric
8/12/2019 TTM GEN FAM 21
25/146
21 - AIR CONDITIONING
DATE : DEC 1997 Page 3 F21TA02
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
Page 17
_
F5M0100GEMetric
8/12/2019 TTM GEN FAM 21
26/146
SELF EXAMINATION
What is the purpose of the pack?
A - To regulate hot air pressure.
B - To adjust the temperature in the four zones.C - To regulate basic temperature.
What is the function of each pack controller?
A - To control the corresponding pack and flow control valve.B - To control the trim air valves.
C - To control the zone controller.
What is the purpose of the zone controller?
A - To control zone temperature.B - To control the flow control valves.C - To control the packs.
21 - AIR CONDITIONING
DATE : DEC 1997 Page 4 F21TA02
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
Page 18
_
F5M0100GEMetric
8/12/2019 TTM GEN FAM 21
27/146
TEMPERATURE CONTROL:
SYSTEM CONTROLS AND INDICATING
AIR Panel
Ram Air Pushbutton SwitchPack 1(2) Pushbutton Switches
Pack Flow SelectorZone Temp SelectorsHot Air 1(2) Pushbutton Switches
P.I.M.Cabin Temp HardkeyTemperature Preselection SoftkeysReset Softkey
Reset Panel
21 - AIR CONDITIONING
DATE : DEC 1997 Page 1 F21TC10
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
Page 19
_
F5M0100GEMetric
8/12/2019 TTM GEN FAM 21
28/146
AIR PANELRAM AIR PUSHBUTTON SWITCH
When the RAM AIR pushbutton is set to ON, on the AIR COND panel, theemergency ram air flaps open provided the ditching pushbutton switch is innormal position on the PRESS panel.
When it is released out, the emergency ram air inlet flap closes.ON : ON light comes on white. Provided the DITCHING pushbuttonswitch is in normal position:
- The ram air inlet flap opens- Both outflow valves open at 50% when P is lower than 1 psi.OFF : The ram air inlet flap closes and the outflow valves return totheir normal position.
PACK 1(2) PUSHBUTTON SWITCHES
When pack 1 ( or pack 2 ) pushbutton is pressed in, the pack flow controlvalve operates if pneumatic pressure is available. When set to OFF, the packflow control valve is maintained closed electrically.
ON : The flow control valve opens provided there is no pack overheat,no engine starting sequence, no upstream pressure below minimum, nocorresponding fire pushbutton released out, no passenger/crew dooropen nor ditching selected.
OFF : The flow control valve closes.FAULT : comes on amber when the flow control valve positiondisagrees with the selected position or in case of pack overheat.
PACK FLOW SELECTOR
The PACK FLOW selector serves to select the pack flow.The PACK FLOW selector enables the pack flow setting to be selected in
accordance with the number of passengers and the ambient conditions.LO : 80% of normal flowNORM : 100%HI : 125% of normal flow.
ZONE TEMPERATURE SELECTORS
The COCKPIT and CABIN temperature selectors enable the selection of thedesired ambient temperature in the corresponding zone.
12 oclock position: 24C
COLD position: 18CHOT position: 30C
HOT AIR 1(2) PUSHBUTTON SWITCHES
When the HOT AIR pushbutton is pressed in, the trim air pressure regulatingvalve opens and pneumatically regulates hot air pressure above the cabinpressure. When set to OFF, the valve is electrically closed.
ON : The valve regulates hot air pressure.
OFF : The valve closes, the trim air valves close and the FAULTcircuit is reset.FAULT : Comes on amber when a duct overheat temperature isdetected (88C). FAULT light goes off when the duct temperature
drops below 70C or OFF is selected .
21 - AIR CONDITIONING
DATE : DEC 1997 Page 2 F21TC10
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
Page 20
_
F5M0100GEMetric
8/12/2019 TTM GEN FAM 21
29/146
21 - AIR CONDITIONING
DATE : DEC 1997 Page 3 F21TC10
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
Page 21
_
F5M0100GEMetric
8/12/2019 TTM GEN FAM 21
30/146
P.I.M.CABIN TEMP HARDKEY
When the CABIN TEMP hardkey is pressed on the Programming andIndicating Module (P.I.M.), the cabin temperature page is displayed. Itprovides the menu for cabin temperature and remote control of the three cabin
zones.
The actual temperature is simultaneously represented by a figure and abargraph. The preselected range is centered on the cockpit selectedtemperature and covers 5 degrees celcius (+/-2.5 DEG C).
The three arrows initially indicate the cockpit selected temperature.The seat row values for each zone depend on the cabin layout selected on the
Cabin Attendant Module (C.A.M.).As an option, all temperatures can be indicated in degrees fahrenheit (64-86
DEG F).
If the actual temperature is lower than 18 DEG C or greater than 30 DEG C,a green arrow is respectively displayed on the left or the right of the bargraph.
21 - AIR CONDITIONING
DATE : DEC 1997 Page 4 F21TC10
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
Page 22
_
F5M0100GEMetric
8/12/2019 TTM GEN FAM 21
31/146
21 - AIR CONDITIONING
DATE : DEC 1997 Page 5 F21TC10
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
Page 23
_
F5M0100GEMetric
8/12/2019 TTM GEN FAM 21
32/146
P.I.M.TEMPERATURE PRESELECTION SOFTKEYSThere are two softkeys per zone wich enable the cabin crew to add orsubstract by increments of 0.5 degrees celcius up to a 2.5 degrees celciusrange around the cockpit selected temperature.The arrow indicating this preselected value moves accordingly on the
temperature bargraph.
respectively disappear if the upper or lowerlimit is reached.
RESET SOFTKEYIf any preselection has been applied, the reset command is available and the
reset indication displayed in white.
When the reset softkey is pressed in, the three arrows indicating the threepreselected values move back to the cockpit selected temperature.
The reset indication becomes green and disappears.
If the cockpit selected temperature is changed, then the three preselectable
ranges are repositioned on the bargraphs and the preselected values reset.
21 - AIR CONDITIONING
DATE : DEC 1997 Page 6 F21TC10
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
Page 24
_
F5M0100GEMetric
8/12/2019 TTM GEN FAM 21
33/146
21 - AIR CONDITIONING
DATE : DEC 1997 Page 7 F21TC10
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
Page 25
_
F5M0100GEMetric
8/12/2019 TTM GEN FAM 21
34/146
RESET PANELA reset control is provided for each controller.Reset is performed by pulling and pushing the corresponding circuit breaker.
21 - AIR CONDITIONING
DATE : DEC 1997 Page 8 F21TC10
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
Page 26
_
F5M0100GEMetric
8/12/2019 TTM GEN FAM 21
35/146
21 - AIR CONDITIONING
DATE : DEC 1997 Page 9 F21TC10
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
Page 27
_
F5M0100GEMetric
8/12/2019 TTM GEN FAM 21
36/146
STUDENT NOTES
21 - AIR CONDITIONING
DATE : DEC 1997 Page 10 F21TC10
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
Page 28
_
F5M0100GEMetric
8/12/2019 TTM GEN FAM 21
37/146
TEMPERATURE CONTROL:
PACK PRESENTATION
Introduction
Exchangers / CompressorPlenum ChamberCheck ValveHigh Pressure Water Separation Loop
Turbine / FanTemperature Control Valve, Ram Air Inlet and Ram AirOutlet FlapsBy Pass Valve
Anti Icing ValveSensors
Downstream Check ValveSelf Examination
21 - AIR CONDITIONING
DATE : FEB 1998 Page 1 F21TE10
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
Page 29
_
F5M0100GEMetric
8/12/2019 TTM GEN FAM 21
38/146
8/12/2019 TTM GEN FAM 21
39/146
21 - AIR CONDITIONING
DATE : FEB 1998 Page 3 F21TE10
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
Page 31
_
F5M0100GEMetric
8/12/2019 TTM GEN FAM 21
40/146
ANTI ICING VALVE
An anti-icing valve prevents ice formation across the condenser by supplyinghot air at the turbine outlet.The anti-ice valve operates according to delta pressures sensed across thecondenser in order to prevent ice build-up at any time.In case of pack controller failure, the anti-icing valve is used also as a
temperature control valve back-up.Its solenoid is then de-energized and the anti-icing valve pneumaticallyoperates under the control of the Pneumatic Temperature Sensor to maintaina pack discharge temperature of approximately 11C (52F).
SENSORS
Pack sensors are used for pack temperature control, monitoring andindicating.
DOWNSTREAM CHECK VALVE
A downstream check valve prevents reverse flow back to the pack.
21 - AIR CONDITIONING
DATE : FEB 1998 Page 4 F21TE10
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
Page 32
_
F5M0100GEMetric
A330 300 TECHNICAL TRAINING MANUAL
8/12/2019 TTM GEN FAM 21
41/146
21 - AIR CONDITIONING
DATE : FEB 1998 Page 5 F21TE10
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
Page 33
_
F5M0100GEMetric
A330 300 TECHNICAL TRAINING MANUAL
8/12/2019 TTM GEN FAM 21
42/146
SELF EXAMINATION
What is the purpose of the temperature control valve ?
A - To reduce the air flow to the compressor stage.
B - To modulate the pack discharge temperature.C - To increase the air flow to the turbine stage.
What is the main purpose of the anti-icing valve ?
A - The anti-icing valve prevents ice formation across theprimary heat exchanger.
B - The anti-icing valve prevents ice formation across the mainheat exchanger.C - The anti-icing valve prevents ice formation across the packcondenser.
What is the purpose of the ram air flaps ?
A - To ensure cabin ventilation if both packs fail.B - To provide air to the pack compressor.C - To modulate the main air flow through the heat exchangers.
What is the purpose of the by-pass valve ?
A - To by-pass the air cycle machine when it is faulty.
B - To by-pass the air cycle machine when its associated packcontroller is faulty.C - To modulate the air flow through the air cycle machine.
What is the purpose of the reheater ?
A - To condense humidity of air into water particles.B - To revaporise remaining water particles not extracted by thewater extractor.
C - To reheat air leaving the turbine.
21 - AIR CONDITIONING
DATE : FEB 1998 Page 6 F21TE10
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
Page 34
_
F5M0100GEMetric
A330 300 TECHNICAL TRAINING MANUAL
8/12/2019 TTM GEN FAM 21
43/146
TEMPERATURE CONTROL :
ECAM PAGE PRESENTATION
Pack Flow Control Valve
Pack Inlet FlowCompressor Outlet TemperatureTemperature Control ValvePack Discharge Temperature
By-pass ValveEmergency Ram AirBleed UsersHot Air 1 (2)
Trim Air Pressure Regulating ValveTrim Air Shut Off Valve
Trim Air ValvesZone Duct Temperature
Zone TemperatureZone Controller StatusAir Ducts
21 - AIR CONDITIONING
DATE : OCT 1997 Page 1 F21TM10
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
Page 35
_
F5M0100GEMetric
A330-300 TECHNICAL TRAINING MANUAL
8/12/2019 TTM GEN FAM 21
44/146
PACK FLOW CONTROL VALVE
The flow control valves indications are normally green.
PACK INLET FLOW
The position of the needle represents the actual rate of pack flow.
COMPRESSOR OUTLET TEMPERATURE
The compressor outlet temperature indications are normally green. The valuevaries by steps of 2C (4F).
GREEN
: Valve not fully closed.
: The pack airflow data is not available.
AMBER CROSSES
: LO = 70% of airflow.
: HI =130% of airflow.
The needle can vary from
62% to 137% of airflow.GREEN NEEDLE
AMBER
: Valve fully closed.
AMBER CROSSES
: Valve position data not available.
AMBER
: The temperature indication exceeds 260C(500F). It becomes green again when thetemperature drops below 180C (356F).
AMBER
: The temperature data is not available.
21 - AIR CONDITIONING
DATE : OCT 1997 Page 2 F21TM10
_A330 300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
Page 36
_
F5M0100GEMetric
8/12/2019 TTM GEN FAM 21
45/146
A330-300 TECHNICAL TRAINING MANUAL
8/12/2019 TTM GEN FAM 21
46/146
TEMPERATURE CONTROL VALVE
The needle position represents the position of the temperature control valve.
PACK DISCHARGE TEMPERATURE
The value represents the pack outlet temperature controlled by the pack
controller. It is normally displayed in green. The value varies by steps of 2C(4F).
: C (Cold) corresponds to a fully closed position.
: H (Hot) corresponds to a fully opened position.
GREEN NEEDLE
: The TCV position data is not available.
AMBER CROSSES
AMBER
: The temperature indication exceeds 95C (203F). It
becomes green again when the temperature drops
below 60C (140F).
AMBER
: The temperature data is not available.
: The TCV is determined faulty.
AMBER NEEDLE
21 - AIR CONDITIONING
DATE : OCT 1997 Page 4 F21TM10
_
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
Page 38
_
F5M0100GEMetric
A330-300 TECHNICAL TRAINING MANUAL
8/12/2019 TTM GEN FAM 21
47/146
21 - AIR CONDITIONING
DATE : OCT 1997 Page 5 F21TM10
_
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
Page 39
_
F5M0100GEMetric
8/12/2019 TTM GEN FAM 21
48/146
21 AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
8/12/2019 TTM GEN FAM 21
49/146
21 - AIR CONDITIONING
DATE : OCT 1997 Page 7 F21TM10
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
Page 41
_
F5M0100GEMetric
21 AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
50/146
EMERGENCY RAM AIR
The Ram air valve indications are normally displayed in green.
BLEED USERS
GREEN
: Valve normally closed.
AMBER VALVE
GREEN DUCTS
: Undetermined position, valve in transit.
GREEN
: Valve normally open.
AMBER CROSSES
: Valve position data not available.
AMBER VALVE
GREEN DUCT
: Valve fully closed and disagrees with command.
AMBER VALVE
GREEN DUCTS
: Valve open on ground or valve position
open but disagrees with command.
GREEN
In normal operation, bleed users are displayed in green
AMBER
The two flow control valves and the Ram-air valve are fully closed.
21 - AIR CONDITIONING
DATE : OCT 1997 Page 8 F21TM10
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
Page 42
_
F5M0100GEMetric
21 AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
51/146
21 - AIR CONDITIONING
DATE : OCT 1997 Page 9 F21TM10
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
Page 43
_
F5M0100GEMetric
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
52/146
HOT AIR 1 (2)
Hot air color indications give the pack flow control valve positions.
TRIM AIR PRESSURE REGULATING VALVE
These indications give the Trim Air Pressure Regulating Valve positions.
GREEN
: Respective flow control valve not fully
closed or valve position data not available
AMBER
: Flow control valve fully closed.
GREEN
: Valve normally closed.
GREEN
: Valve normally open.
AMBER
: Valve abnormally closed.
AMBER
: Valve abnormally open.
AMBER CROSSES
GREEN CIRCLE
: Position data not available.
21 - AIR CONDITIONING
DATE : OCT 1997 Page 10 F21TM10
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
Page 44
_
F5M0100GEMetric
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
53/146
21 AIR CONDITIONING
DATE : OCT 1997 Page 11 F21TM10
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
Page 45
_
F5M0100GEMetric
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
54/146
TRIM AIR SHUT OFF VALVE
These indications give the Trim Air Shut-off Valve position.
TRIM AIR VALVES
The position of the needle represents the valve position and consequently thehot air flow.
GREEN
: Valve normally closed.
GREEN
: Valve normally open.
AMBER
: Valve abnormally closed.
AMBER CROSSES
: Position data not available.
: H (Hot), valve fully open.
: C (Cold), valve fully closed.
GREEN NEEDLE
: Valve position data is not available.
AMBER CROSSES
21 AIR CONDITIONING
DATE : OCT 1997 Page 12 F21TM10Page 46
_
F5M0100GEMetric
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
55/146
DATE : OCT 1997 Page 13 F21TM10Page 47
_
F5M0100GEMetric
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
56/146
ZONE DUCT TEMPERATURE
The zone duct temperature indications are normally displayed in green. The
temperature varies by steps of 2C (4F).
ZONE TEMPERATUREThe zone temperature indications are always displayed in green. Thetemperature varies by steps of 1C (2F).
These indications are also displayed on the ECAM CRUISE page.The temperature varies by steps of 1C (2F).
A green pulsing flow increase request warning is displayed when the flow is
insufficient to reach the selected temperature.
AMBER
: The temperature indication exceeds 88C
(190F). It becomes green again when the
temperature drops below 70C (158F).
AMBER
: The temperature data is not available.
GREEN
: Temperature normal display.
AMBER
: The temperature data is not available.
: This green pulsing message is displayed
when the air flow is insufficient to reach
the selected zone temperature.
Not displayed otherwise.GREEN
GREEN
: Temperature normal display.
AMBER
: The temperature data is not available.
DATE : OCT 1997 Page 14 F21TM10Page 48
_
F5M0100GEMetric
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
57/146
DATE : OCT 1997 Page 15 F21TM10Page 49
_
F5M0100GEMetric
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
58/146
ZONE CONTROLLER STATUS
The PACK REG indication appears in green when the zone controller isinoperative.
AIR DUCTS
The ducts are normally colored in green.
: The zone controller is inoperative (both
channels are faulty) or the data related to
the zone controller state is not available.GREEN
The air distribution is not yet operative
(engine starting sequence) or air system
failure or associated FCV fully closed..
AMBER
DATE : OCT 1997 Page 16 F21TM10Page 50
_
F5M0100GEMetric
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
59/146
DATE : OCT 1997 Page 17 F21TM10Page 51
_
F5M0100GEMetric
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
60/146
STUDENT NOTES
DATE : OCT 1997 Page 18 F21TM10Page 52
_
F5M0100GEMetric
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
61/146
COCKPIT / CABIN VENTILATION :
SYSTEM PRESENTATION
COCKPIT/CABIN
GeneralFiltersClogging Indicators
Recirculation FansCheck ValvesRecirculation ValvesAir Outlets
LAVATORY/GALLEY
General
Extraction FanDifferential Pressure SwitchSafety SwitchSelf Examination
DATE : OCT 1997 Page 1 F21CA10Page 53
_
F5M0100GEMetric
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
62/146
COCKPIT/CABIN
GENERALCabins are ventilated by mixed air from the mixer unit and hot airfrom the trim air valves.
The cockpit is ventilated with fresh air from pack 1 mainly and hot airfrom its dedicated trim air valve.
FILTERSFilters are installed at the inlet of the cabin air recirculation circuit.
CLOGGING INDICATORSThe clogging indicators are differential pressure switches used togenerate maintenance information in case of filter clogging.
RECIRCULATION FANSTwo recirculation fans feed the mixer unit with air from the cabin.In addition, they are used as blowers for the avionics ventilation.
The recirculation fans are controlled from the CAB FANS pushbuttonswitch on the overhead panel.The fans automatically stop in case of DITCHING.
CHECK VALVES
Check valves are installed to prevent reverse flow when recirculationfans are OFF.
RECIRCULATION VALVESThe recirculation valves are normally open.
They close when both packs are OFF to keep the avionics equipmentsufficiently ventilated.
The signal indicating that both packs are OFF is sent by the zonecontroller.
AIR OUTLETSConditioned air tapped from the main distribution ducts is sent to the
individual and fixed air outlets.
DATE : OCT 1997 Page 2 F21CA10Page 54
_
F5M0100GEMetric
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
63/146
DATE : OCT 1997 Page 3 F21CA10Page 55
_
F5M0100GEMetric
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
64/146
LAVATORY/GALLEY
GENERALLavatory and galley ventilation air is ducted from the main cabin airdistribution supply.
Air is discharged overboard by differential pressure or by anExtraction Fan.
Cabin temperature sensors are ventilated with cabin air drawn by the
Extraction Fan.
EXTRACTION FAN
The Extraction Fan operates on ground when electrical power isavailable and in flight when delta P is lower than 1 psi.
The Extraction Fan is controlled by the ventilation controller.
The ground/flight signal comes from Landing Gear Control InterfaceUnit 2 (LGCIU).
DIFFERENTIAL PRESSURE SWITCHThe Differential Pressure Switch serves to detect when delta P is lowerthan 1 psi for extraction fan operation control.
SAFETY SWITCHA Safety Switch detects any abnormal low pressure and sends signals
to the ventilation controller for condition monitoring.
DATE : OCT 1997 Page 4 F21CA10Page 56
_
F5M0100GEMetric
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
65/146
DATE : OCT 1997 Page 5 F21CA10Page 57
_
F5M0100GEMetric
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
66/146
SELF EXAMINATION
When does the lavatory and galley extraction fan operate ?
A - On ground when P is higher than 1 psi and in flight whenP is lower than 1 PSI.B - Always when electrical power is available.
C - On ground when electrical power is available and in flight
when P is lower than 1 psi.
When do the recirculation valves close ?
A - When both packs are OFF.B - When pack 1 is OFF.C - When pack 2 is OFF.
DATE : OCT 1997 Page 6 F21CA10Page 58
_
F5M0100GEMetric
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
67/146
COCKPIT / CABIN VENTILATION :
SYSTEM CONTROLS AND INDICATING
Cab Fans Pushbutton Switch
Fans Reset Pushbutton
Fan Indication
DATE : OCT 1997 Page 1 F21CB10Page 59
_
F5M0100GEMetric
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
68/146
CAB FANS PUSHBUTTON SWITCH
The CAB FANS pushbutton switch enables the crew to simultaneously stopboth recirculation fans. When the CAB FANS pushbutton switch is pressedin, both recirculation fans run provided there is no overheat condition.
Both recirculation fans are switched off.
FANS RESET PUSHBUTTON
The Fan Reset pushbutton indicates an overheat of at least one fan controlledby the ventilation controller and enables the crew to reset it.
There is a recirculation fan overheat.
When the P/B is pressed, the fan restarts and the fault
light goes off provided the overheat condition hasdisappeared.
FAN INDICATION
The fan indication is not displayed in normal operation or when the fan statedata is not available.
The respective recirculation fan is faulty, or the CAB
FANS pushbutton switch is selected OFF or theventilation controller is faulty.
DATE : OCT 1997 Page 2 F21CB10Page 60
_
F5M0100GEMetric
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
69/146
DATE : OCT 1997 Page 3 F21CB10Page 61
_
F5M0100GEMetric
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
70/146
STUDENT NOTES
DATE : OCT 1997 Page 4 F21CB10Page 62
_
F5M0100GEMetric
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
71/146
AFT GALLEY AREA HEATING SYSTEM
PRESENTATION
General
Power Supply Logic
Control And IndicatingThermal Protection
DATE : APR 1999 Page 1 F21EA01Page 63
_
F5M0100GEMetric
GENERAL
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
72/146
GENERAL
The aft galley-area heating system increases the temperature of the air in theaft galley area.The air comes from the cabin air supply area and flows through a heaterlocated in the upper part of the aft galley.
POWER SUPPLY LOGIC
The heater is powered by the 115 VAC service bus.The 115 VAC is available only if at least one air conditioning pack operatesand galley power is "ON", provided the cargo loading is not operating.
CONTROL AND INDICATINGAs soon as all the heater supply initial conditions are fulfilled, the "AVAIL"indication illuminates on the aft GALLEY AREA HEATING panel meaning
that the heater is available.
Two temperature settings (low or high) can be selected through two p/bswitches located on the GALLEY AREA HEATING panel.
The "LOW ON" selection powers one heating element while the "HIGH ON"selection powers the three elements.
THERMAL PROTECTION
In case of heater overheat the thermal switch opens. This causes the heatersupply to be interrupted.The "AVAIL" indication on the GALLEY AREA HEATING panel willextinguish as long as the overheat exits.
DATE : APR 1999 Page 2 F21EA01Page 64
_
F5M0100GEMetric
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
73/146
DATE : APR 1999 Page 3 F21EA01Page 65
_
F5M0100GEMetric
STUDENT NOTES
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
74/146
STUDENT NOTES
DATE : APR 1999 Page 4 F21EA01Page 66
_
F5M0100GEMetric
8/12/2019 TTM GEN FAM 21
75/146
INTERFACEGROUND REFRIGERATION SYSTEM (OPTIONAL)
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
76/146
INTERFACE
RECIRCULATION SYSTEM
The recirculation fans of the cockpit and cabin ventilation system arealso used as blower fans for the avionics equipment ventilation.
The recirculation fans are controlled, via the ventilation controller,from the VENTILATION panel.
The recirculation valves are normally open.They close when both packs are OFF to keep the avionics equipment
sufficiently ventilated.
The valves are controlled and monitored by the ventilation controller.
AVIONICS VENTILATION SYSTEM
GENERAL
Vent air is supplied either from the recirculation system or from thepacks.Air is extracted by means of an extraction fan.Air is discharged either overboard through the overboard valve or
under the cargo floor through the underfloor valve.
When the overboard valve is open, the underfloor valve is closed andvice versa.
A ground horn sounds in case of abnormal operation on ground.
The cooling capacity is monitored by two sensors (Cooling EffectDetector and pressure switch).
All avionics ventilation system components are controlled andmonitored by the Avionics Equipment Ventilation Computer (AEVC).
The ground refrigeration system cools the air of the avionicsventilation system.The Ground Refrigeration Unit (GRU) is a freon gas closed-cyclerefrigeration system which operates on a compression expansionprinciple. The GRU is designed to meet the new environmental
requirements.
It operates when the aircraft is on ground with all engines and bothpacks stopped, ditching not selected, GND COOL pushbutton switch
on AUTO and the recirculated air temperature higher than 27C.
Control and monitoring are performed by the Avionics EquipmentVentilation Computer.
The ground/flight signal comes from LGCIU 1 and 2.The engines 1 and 2 stopped signal comes from the oil low pressureswitches (1 and 2). The ditching signal comes from the PRESS panel.
When the system operates, the fan runs and the heat accumulated in
the condenser is extracted through the skin air valve.
EXTRACTION FAN
The extraction fan draws the air from the avionics equipment.It is monitored by the Avionics Equipment Ventilation Computer.
It runs continuously whenever electrical power is available.
DATE : APR 1999 Page 2 F21VA04Page 68
_
F5M0100GEMetric
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
77/146
DATE : APR 1999 Page 3 F21VA04Page 69
_
F5M0100GEMetric
OVERBOARD VALVE PRESSURE SWITCH
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
78/146
In AUTO mode, air is extracted through the overboard valve providedthe aircraft is on ground and engines 1 and 2 stopped.
The overboard valve will receive a signal to close if DITCHING isselected on the PRESS panel.
Manual OVRD selection on EXTRACT pushbutton switch controlspartial opening of the overboard valve.In flight it will ensure equipment ventilation by differential pressure.
This manual selection is done in case of low flow detection or avionicssmoke procedure.
UNDERFLOOR VALVE
The underfloor valve is closed and the overboard valve is open,provided the EXTRACT pushbutton switch is in AUTO position,
engines 1 and 2 stopped, and the aircraft on ground.
In flight, the extracted air is discharged below the forward cargocompartment floor via the underfloor valve, the overboard valve being
closed.
If the OVRD position is selected, the underfloor valve closes to allowthe air to be sent overboard via the overboard valve.
COOLING EFFECT DETECTOR (CED)
The Cooling Effect Detector provides a warning signal when the
cooling capacity of the recirculated air is insufficient.
The Pressure Switch signals a low pressure to the Avionics EquipmentVentilation Computer in order to detect any low flow.
In case of low flow, the FAULT light on the EXTRACT pushbuttonswitch comes on and an electrical signal is sent to the ECAM and
ground horn.
AIR CONDITIONING BAY VENTILATION
TURBOFAN AND SUPPLY VALVE
The air conditioning bay is ventilated by external air to preventstructural damage. With the aircraft on ground, the turbofan boosts airinto the ventilation circuit.The turbofan is driven as soon as it receives air from the cross bleed
duct via the supply valve.
In flight, the supply valve being closed, ventilation is performed byram air from NACA air inlet.
When the turbofan is in windmilling configuration, the overflowbypasses the turbofan through the check valve.
PRESSURE SWITCH
A pressure switch signals an abnormal ventilation to the AvionicsEquipment Ventilation Computer.
DATE : APR 1999 Page 4 F21VA04Page 70
_
F5M0100GEMetric
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
79/146
DATE : APR 1999 Page 5 F21VA04Page 71
_
F5M0100GEMetric
SELF EXAMINATION
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
80/146
What is the position of the avionics ventilation valves on ground,engines 1 and 2 stopped and in AUTO mode ?
A - Underfloor valve closed - Overboard valve open.B - Underfloor valve open - Overboard valve closed.C - Underfloor valve closed - Overboard valve partially open.
What is the position of the avionics ventilation valves in flight in AUTOmode ?
A - Underfloor valve open - Overboard valve closed.B - Underfloor valve closed - Overboard valve open.C - Underfloor valve closed - Overboard valve partially open.
What is the position of the avionics ventilation valves when OVRD is
selected on the EXTRACT pushbutton ?
A - Underfloor valve open - Overboard valve partially open.B - Underfloor valve closed - Overboard valve open.C - Underfloor valve closed - Overboard valve partially open.
On ground, what is the correct configuration for the air conditioning bayventilation system ?
A - Supply valve open - Turbofan operating.B - Supply valve closed - Turbofan in windmilling.C - Supply valve open - Turbofan stopped.
DATE : APR 1999 Page 6 F21VA04Page 72
_
F5M0100GEMetric
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
81/146
AVIONICS / AIR CONDITIONING BAY
VENTILATION :SYSTEM CONTROLS AND INDICATING
Extract P/B
OVBD ValveVent
DATE : OCT 1997 Page 1 F21VB01Page 73
_
F5M0100GEMetric
8/12/2019 TTM GEN FAM 21
82/146
8/12/2019 TTM GEN FAM 21
83/146
STUDENT NOTES
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
84/146
DATE : OCT 1997 Page 4 F21VB01Page 76
_
F5M0100GEMetric
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
85/146
AVIONICS EQUIPMENT GROUND COOLING :
SYSTEM CONTROLS AND INDICATING
Ground Cooling P/B
Skin ValveGround Cooling Indication
DATE : NOV 1997 Page 1 F21VO01Page 77
_
F5M0100GEMetric
GROUND COOLING P/B
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
86/146
The ground cooling system is automatically controlled by the avionicsequipment ventilation computer provided that the GROUND COOLpushbutton switch is set to AUTO.In case of system malfunction, the GROUND COOL pushbutton switch mustbe set to OFF.
A/C on ground, engines stopped : Skin valve opens.
Skin valve open and recirculation air temperature >27C (80F): fan andcompressor run.FAULT : in amber : Ground Refrigeration Unit (GRU), fan or valve failure.OFF : in white : the skin valve closes , the fan and the GRU stop.
DATE : NOV 1997 Page 2 F21VO01Page 78
_
F5M0100GEMetric
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
87/146
DATE : NOV 1997 Page 3 F21VO01Page 79
_
F5M0100GEMetric
SKIN VALVE
The skin al e position indication is normall green It becomes amber in
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
88/146
The skin valve position indication is normally green. It becomes amber incase of abnormal position.
GROUND COOLING INDICATION
The GROUND COOL indication is normally white. It becomes amber whenthe skin valve position indication is displayed amber or when the groundcooling system is faulty.GND COOL : white : Normal operation or when the ground cooling system
status is not available.GND COOL : amber : When the skin air valve is displayed amber or whenthe ground cooling system is faulty.
DATE : NOV 1997 Page 4 F21VO01Page 80
_
F5M0100GEMetric
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
89/146
FORWARD CARGO COMPARTMENT
VENTILATION / TEMPERATURE CONTROL :SYSTEM PRESENTATION
General
Inlet Isolation ValvesTrim Air ValveCold Air Valve
Outlet Isolation ValveExtraction FanTemp SensorSelf Examination
DATE : OCT 1997 Page 1 F21FA02Page 81
_
F5M0100GEMetric
GENERAL
The forward cargo compartment is ventilated by cabin air cooled by cold airf k 2 d h t d b h t i f t i i l ti l 1
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
90/146
The forward cargo compartment is ventilated by cabin air, cooled by cold airfrom pack 2 and heated by hot air from trim air pressure regulating valve 1.
DATE : OCT 1997 Page 2 F21FA02Page 82
_
F5M0100GEMetric
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
91/146
DATE : OCT 1997 Page 3 F21FA02Page 83
_
F5M0100GEMetric
8/12/2019 TTM GEN FAM 21
92/146
8/12/2019 TTM GEN FAM 21
93/146
SELF EXAMINATION
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
94/146
What is the cold air source for cargo cooling ?
A - Pack 1.
B - Pack 2.C - Mixer unit.
When do the isolation valves close ?
A - In case of Forward cargo smoke warning.B - In case of extraction fan failed.
C - In case of both packs failed.
Which valve closes in case of duct overheat detection ?
A - Outlet isolation valve.
B - Cold air valve.C - Cargo trim air valve.
DATE : OCT 1997 Page 6 F21FA02Page 86
_
F5M0100GEMetric
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
95/146
FORWARD CARGO COMPARTMENT
VENTILATION / TEMPERATURE CONTROL :SYSTEM CONTROLS AND INDICATING
Isolation Valves P/BCooling SelectorTemperature SelectorFan Reset P/B
Trim Air ValveCold AirCold Air ValveDuct Temperature
Compartment Temperature
DATE : MAY 1999 Page 1 F21FB10Page 87
_
F5M0100GEMetric
As these systems are optional, the indications concerning the FWD cargocompartment temperature control system are displayed on the ECAM CONDand CRUISE pages only if the option is fitted on the aircraft and the
ISOLATION VALVES P/B
When the isolation valves pushbutton switch is pressed in, theisolation valves open and the extraction fan runs provided there is no
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
96/146
ventilation controller pinprogrammed.
These indications are displayed on ECAM only if the BULK CARGO
HEATING system is installed.
smoke detection in the FWD cargo compartment.
FAULT comes on associated with an ECAM caution when
either the inlet or outlet isolation valve is not in agreement withthe selected position.
The pushbutton is released out. The valves close and the
extraction fan stops.
COOLING SELECTOR
The COOLING selector controls the cold air valve via the ventilationcontroller to adjust the quantity of cold air supplied by the mixer unit.The COOLING selector has three positions.
Cold air valve partially open.
Cold air valvefully closed.
Cold air valvefully open.
DATE : MAY 1999 Page 2 F21FB10Page 88
_
F5M0100GEMetric
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
97/146
DATE : MAY 1999 Page 3 F21FB10Page 89
_
F5M0100GEMetric
TEMPERATURE SELECTOR
The forward cargo compartment temperature can be adjusted with thetemperature rotary selector
TRIM AIR VALVE
The forward cargo trim air valve indication is normally displayed ingreen on the ECAM COND page.
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
98/146
temperature rotary selector.
The temperature regulation is performed by changing the FWD cargoTrim Air Valve position.
FAN RESET P/B
The Fan Reset pushbutton indicates an overheat of at least one fan
controlled by the ventilation controller and enables the crew to resetit.
There is an extraction fan overheat.
When the P/B is pressed, the fan restarts and the fault light goesoff provided the overheat condition has disappeared.
Normal operation.C (COLD) = Valve closed.
H (HOT) = Valve open.
The trim air valve has failed.
The trim air valve position data is not available.
COLD AIR
The cold air duct indication is normally displayed in green on theECAM COND page.
The duct is green when the two flow control valves are notfully closed or when their position is not available.
It becomes amber when one of the two flow control valves arefully closed.
DATE : MAY 1999 Page 4 F21FB10Page 90
_
F5M0100GEMetric
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
99/146
DATE : MAY 1999 Page 5 F21FB10Page 91
_
F5M0100GEMetric
COLD AIR VALVE
The cold air valve indication is normally displayed in green on theECAM COND page.
COMPARTMENT TEMPERATURE
The forward cargo compartment temperature is always displayed ingreen on the ECAM COND page.
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
100/146
Valve partially open.
Valve fully closed.
Valve fully open.
Valve abnormal fully closed.
Valve abnormally fully open.
Valve abnormally partially open or in transit position.
Valve position data not available.
DUCT TEMPERATUREThe forward cargo duct temperature is normally displayed in green onthe ECAM COND page.
UDTS = Upper Duct Temp. SensorLDTS = Lower Duct Temp. Sensor
The duct temperature is lower than 88C (190F).
The duct temperature is greater than 88C (190F).
The duct temperature data is not available.
CTS = Compartment Temp. Sensor
Normal configuration.Temperature varies by steps of 1C (2F).
The FWD cargo compartment temperature data is not available.
The FWD cargo compartment temperature is also displayed in greenon the ECAM CRUISE page.
Normal configuration.Temperature varies by steps of 1C (2F).
The FWD cargo compartment temperature data is not available.
DATE : MAY 1999 Page 6 F21FB10Page 92
_
F5M0100GEMetric
AFT CARGO COMPARTMENT VENTILATION :
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
101/146
AFT CARGO COMPARTMENT VENTILATION :
SYSTEM PRESENTATION
General
Inlet Isolation ValvesExtraction Fan
Outlet Isolation ValveSelf Examination
DATE : OCT 1997 Page 1 F21AA02Page 93
_
F5M0100GEMetric
GENERAL
The aft cargo compartment is ventilated with cabin air.
INLET ISOLATION VALVES
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
102/146
INLET ISOLATION VALVES
The inlet isolation valves allow cabin air, from openings in the cabin floor,
to enter the compartment.Control is achieved, via the ventilation controller, by the ISOL VALVESpushbutton switch.
To isolate the cargo compartment, they close if DITCHING is selected or if
smoke is detected in the AFT or Bulk cargo compartment.
EXTRACTION FAN
The extraction fan extracts the air from the cargo compartment.
The extraction fan operates provided at least one inlet isolation valve is open
and the outlet isolation valve is open.It stops if smoke is detected in the AFT or Bulk cargo compartment.
OUTLET ISOLATION VALVE
The outlet isolation valve allows the air to be ducted overboard through theAFT outflow valve.Control is achieved, via the ventilation controller, by the ISOL VALVES
pushbutton switch.
To isolate the cargo compartment, it closes if DITCHING is selected or ifsmoke is detected in the AFT or Bulk cargo compartment.
DATE : OCT 1997 Page 2 F21AA02Page 94
_
F5M0100GEMetric
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
103/146
DATE : OCT 1997 Page 3 F21AA02Page 95
_
F5M0100GEMetric
SELF EXAMINATION
When do the isolation valves close ?
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
104/146
A - In case of AFT cargo smoke warning.
B - In case of extraction fan failed.C - In case of both packs OFF.
DATE : OCT 1997 Page 4 F21AA02Page 96
_
F5M0100GEMetric
8/12/2019 TTM GEN FAM 21
105/146
ISOLATION VALVES P/B
When the isolation valve pushbutton switch is pressed, the isolation valves
open and the extraction fan runs provided there is no smoke detection in theaft cargo compartment.
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
106/146
FAULT (in amber) : comes on associated with ECAM caution when either
inlet or outlet valve is not in agreement with the selected position.
OFF (in white) : the isolation valves pushbutton switch released out, thevalves close and the extraction fan stops.
FANS RESET P/B
The FAN RESET pushbutton switch indicates an overheat of at least one fanof the air conditioning system and enables the crew to reset it.
If there is a fan overheat, a FAULT light (in amber) on the OVHT CONDFANS RESET pushbutton switch comes on and the extraction fan stops.When this reset pushbutton switch is pressed, the extraction fan is reset bymeans of the ventilation controller and the fault light goes off.
DATE : DEC 1997 Page 2 F21AB02Page 98
_
F5M0100GEMetric
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
107/146
DATE : DEC 1997 Page 3 F21AB02Page 99
_
F5M0100GEMetric
STUDENT NOTES :
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
108/146
DATE : DEC 1997 Page 4 F21AB02Page 100
_
F5M0100GEMetric
BULK CARGO COMPARTMENT
VENTILATION / HEATING :
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
109/146
VENTILATION / HEATING :SYSTEM PRESENTATION
GeneralInlet Isolation Valve
Extraction FanOutlet Isolation Valve
Fan Heater (Optional)Duct and Compartment Temperature Sensors (Optional)Self Examination
DATE : OCT 1997 Page 1 F21BA10Page 101
_
F5M0100GEMetri
c
GENERAL
The bulk cargo compartment is ventilated with cabin air by means of an
extraction fan. An optional heating system may be fitted on the aircraft.Heating is then performed by an electrical fan heater.
INLET ISOLATION VALVE
FAN HEATER (OPTIONAL)
The optional fan heater is controlled by the Ventilation Controller according
to the cockpit panel selection. It operates provided the inlet and the outletisolation valves are open.It automatically stops in case of Bulk cargo door open (PSCU), smoke
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
110/146
INLET ISOLATION VALVE
The inlet isolation valve allows cabin air to enter the Bulk cargo compartmentthrough an elbow duct . Control is achieved, via the ventilation controller, bythe ISOL VALVES pushbutton switch.To isolate the cargo compartment, it closes if DITCHING is selected or if
smoke is detected in the Bulk or AFT cargo compartment.
EXTRACTION FAN
The extraction fan extracts the compartment air.
The extraction fan operates provided the isolation valves are open.It stops if smoke is detected in the Bulk or AFT cargo compartment.
OUTLET ISOLATION VALVE
The outlet isolation valve allows air to be sent overboard through the AFToutflow valve. Control is achieved, via the ventilation controller, by the ISOLVALVES pushbutton switch.
To isolate the cargo compartment, it closes if ditching is selected or if smokeis detected in the Bulk or AFT cargo compartment.
detected in the AFT or Bulk cargo compartment (SDCU) or duct or fan
overheat detection.
DUCT AND COMPARTMENT TEMPERATURE SENSORS
(OPTIONAL)
If the optional heating system is fitted on the aircraft, temperature sensors are
installed for temperature control and duct temperature overheat detection.
DATE : OCT 1997 Page 2 F21BA10Page 102
_
F5M0100GEMetric
8/12/2019 TTM GEN FAM 21
111/146
SELF EXAMINATION
When do the isolation valves close ?
A If B lk k i d t t d
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
112/146
A - If Bulk cargo smoke is detected.
B - If the extraction fan fails.C - In case of both packs OFF.
When does the optional fan heater automatically stop ?
A - When the Bulk cargo door is open.B - When the AFT outflow valve is open.
C - When a passenger door is open.
DATE : OCT 1997 Page 4 F21BA10Page 104
_
F5M0100GEMetric
BULK CARGO COMPARTMENT
VENTILATION / HEATING :
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
113/146
SYSTEM CONTROLS AND INDICATING
Isol Valves PushbuttonFans Reset Pushbutton
Heating P/BTemperature Selector
Fan Heater IndicationDuct TemperatureZone Temperature
DATE : OCT 1997 Page 1 F21BB10Page 105
_
F5M0100GEMetric
The indications concerning the bulk cargo compartment temperature controlsystem are displayed on the ECAM COND and CRUISE pages only if the
option is fitted on the aircraft and the ventilation controller pinprogrammed.
These indications are displayed on ECAM only if the FWD CARGO TEMPCONTROL is installed
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
114/146
CONTROL is installed.
DATE : OCT 1997 Page 2 F21BB10Page 106
_
F5M0100GEMetric
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
115/146
DATE : OCT 1997 Page 3 F21BB10Page 107
_
F5M0100GEMetr
ic
ISOL VALVES PUSHBUTTON
When the isolation valves pushbutton switch is pressed in, the isolation
valves open and the extraction fan runs provided there is no smoke detectionin the bulk cargo compartment.
HEATING P/B
When the heating pushbutton switch is pressed in, the fan heater is activated
provided the isolation valves are open.
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
116/146
FAULT comes on associated with an ECAM cautionwhen either the inlet or outlet isolation valve is notin agreement with the selected position.
The pushbutton is released out. The valves close andthe extraction fan stops.
FANS RESET PUSHBUTTON
The Fan Reset pushbutton indicates an overheat of at least one fan controlled
by the ventilation controller and enables the crew to reset it.
There is an extraction fan or fan heater fan partoverheat.
When the P/B is pressed, the fan restarts and the faultlight goes off provided the overheat condition hasdisappeared.
The duct temperature is greater than 88C(190F). The overheat condition can be resetprovided the duct temperature is lower than70C (158F).
The heating pushbutton is released out and thefan heater stopped.
TEMPERATURE SELECTOR
The bulk cargo compartment temperature can be adjusted with the
temperature rotary selector.
The temperature regulation is performed by changing
the fan heater power supply controlled by theventilator controller.
DATE : OCT 1997 Page 4 F21BB10Page 108
_
F5M0100GEMetr
ic
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
117/146
DATE : OCT 1997 Page 5 F21BB10Page 109
_
F5M0100GEMetr
ic
FAN HEATER INDICATION
The arrow representing the bulk cargo fan heater performance is normally
displayed in green on the ECAM COND page.
C (COLD) = minimum performance.H (HOT) = maximum performance.
ZONE TEMPERATURE
The bulk cargo compartment temperature is always displayed in green on the
ECAM COND page.
Normal configuration. Temperature varies by steps
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
118/146
The fan heater has failed.
The fan heater performance data is not available.
DUCT TEMPERATURE
The bulk cargo duct temperature is normally displayed in green on the ECAM
COND page.
The duct temperature is lower than 88C (190F).
The duct temperature is greater than 88C (190F).
The duct temperature data is not available.
of 1C (2F).
The bulk cargo compartment temperature data is notavailable.
The bulk cargo compartment temperature is also displayed in green on the
ECAM CRUISE page.
Normal configuration. Temperature varies by steps
of 1C (2F).
The bulk cargo compartment temperature data is not
available.
DATE : OCT 1997 Page 6 F21BB10Page 110
_
F5M0100GEMetric
PRESSURIZATION :
SYSTEM DESIGN PHILOSOPHY
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
119/146
General
Design Philosophy
DATE : DEC 1997 Page 1 F21PA02Page 111
_
F5M0100GEMetric
GENERAL
The pressurization system ensures a cabin altitude safe and compatible with
crew and passenger comfort.Pressurization is performed by controlling the amount of air dischargedoverboard through two outflow valves.
DESIGN PHILOSOPHY
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
120/146
DESIGN PHILOSOPHY
The system has two identical and independent automatic controllers.Only one controller operates at a time, the other is in active stand-by.
In normal condition, the system operation is fully automatic.The operation of the automatic cabin pressure control depends onpre-programmed control laws and information from the ADIRUs.The automatic cabin pressure control is achieved from internal schedules, or
external schedules if the FMGES inputs are available, such as top of climb.
The CABIN PRESS panel enables manual cabin pressure control in case offailure of both automatic systems. The FWD and AFT valves may be
simultaneously or independently manually controlled.
A mixed mode is available mainly in case of cabin compartment smoke
evacuation. In mixed mode, one outflow valve may be manually controlledwhereas the other one remains under automatic control (active cabin pressurecontroller).
Two safety valves are installed on the aft pressure bulkhead to prevent
excessive positive or negative differential pressure.Due to the large volume of the fuselage, a negative pressure relief valveassists the safety valves to prevent negative differential pressure.
DATE : DEC 1997 Page 2 F21PA02Page 112
_
F5M0100GEMetric
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
121/146
DATE : DEC 1997 Page 3 F21PA02Page 113
_
F5M0100GEMetric
SELF EXAMINATION
What is the number of outflow valves, safety valves and negative pressurerelief valves ?
A - One outflow valve two safety valves and one negative
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
122/146
A One outflow valve, two safety valves and one negativepressure relief valve.B - Two outflow valves, two safety valves and one negativepressure relief valve.
C - Two outflow valves, one safety valve and one negativepressure relief valve.
What is the purpose of the negative pressure relief valve ?
A - To avoid over-temperature.B - To prevent negative differential pressure.
C - To prevent positive differential pressure.
What is the purpose of the safety valves ?
A - To avoid negative differential pressure.B - To replace the outflow valves.C - To prevent excessive differential pressure.
DATE : DEC 1997 Page 4 F21PA02Page 114
_
F5M0100GEMetric
PRESSURIZATION :
SYSTEM CONTROLS AND INDICATING
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
123/146
Active Valve Selector
MAN V/S Toggle SwitchMODE SEL P/B SwitchLanding Field Elevation SelectorDitching P/B Switch
CPC Reset Switches
DATE : DEC 1997 Page 1 F21PC10Page 115
_
F5M0100GEMet
ric
8/12/2019 TTM GEN FAM 21
124/146
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
125/146
DATE : DEC 1997 Page 3 F21PC10Page 117
_
F5M0100GEMetric
STUDENT NOTES
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
126/146
DATE : DEC 1997 Page 4 F21PC10Page 118
_
F5M0100GEMetric
PRESSURIZATION: FLIGHT PROFILE
Ground
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
127/146
GroundTake-off
ClimbCruiseDescent
Ground
DATE : MAR 1999 Page 1 F21PF09Page 119
_
F5M0100GEMetric
8/12/2019 TTM GEN FAM 21
128/146
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
129/146
DATE : MAR 1999 Page 3 F21PF09Page 121
_
F5M0100GEMe
tric
8/12/2019 TTM GEN FAM 21
130/146
SELF EXAMINATION
What is the position of the outflow valves in ground mode?
A - Half open.
B - Fully closed.C - Fully open.
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
131/146
y p
DATE : MAR 1999 Page 5 F21PF09Page 123
_
F5M0100GEMe
tric
STUDENT NOTES
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
132/146
DATE : MAR 1999 Page 6 F21PF09Page 124
_
F5M0100GEMe
tric
PRESSURIZATION:
ECAM PAGE PRESENTATION
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
133/146
Packs
Outflow ValvesSafety ValvesActive System
ManLFE Selection ModeLFE Value
Cabin PCabin V/SCabin Altitude
DATE : DEC 1997 Page 1 F21PG10Page 125
_
F5M0100GEMe
tric
OUTFLOW VALVES
The Outflow Valve indication gives the respective outflow valve position.
The needle is normally green and the FWD and AFT indications white.
: The valve is opened more than 95% during flight or
it is determined faulty (only in auto press mode).
ECAM CAB PRESS PAGE
WHITE LETTERS
GREEN NEEDLE
: These indications are displayed on ECAM
only if the optional ground cooling system isfitted on the aicraft.
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
134/146
PACKS
The Pack indication gives the respective flow control valve status.
ECAM CRUISE PAGE
GREEN LETTERS
AMBER TRIANGLE
AND LETTERS
: The respective flow control valve is fully closed.
GREEN TRIANGLE
:The respective flow control valve is not fully closed.
AMBER CROSSES
WHITE LETTERS
: The respective flow control valve
position data is not available.
AMBER LETTERS
AND NEEDLE
WHITE LETTERS
AMBER CROSSES
: The valve position data is not available.
: These indications are displayed on ECAM
only if the optional FWD and BULK cargo
temperature control systems are fitted on the
aircraft.
DATE : DEC 1997 Page 2 F21PG10Page 126
_
F5M0100GEMe
tric
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
135/146
DATE : DEC 1997 Page 3 F21PG10Page 127
_
F5M0100GEMe
tric
SAFETY VALVES
The safety valve indication gives the safety valve status. The position signals
are provided to the SDAC by a discrete signal from the valves sensor.
ACTIVE SYSTEM
It indicates which system is active and what is the system status.
Only one system is active at a time.When both systems are faulty, the "FAULT" light on the MODESEL pushbutton comes on.
: System 1 is active and not faulty.
: Both safety valves are fully closed.
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
136/146
MAN
The MAN indication appears in green above the outflow valve indication
when its corresponding valve is manually controlled.MAN indication is not displayed otherwise.
AMBER
GREEN
AMBER
: System 1 is faulty.
: System status data is not available.
GREEN
: The corresponding outflow valve is manually controlled.
WHITE LETTERS
AMBER CROSSES
: Both safety valves position data are not available
or one is not available and the other valve is closed.
AMBER LETTERS
AND NEEDLE
: At least one of the safety valves is not fully closed.
GREEN NEEDLE
WHITE LETTERS
DATE : DEC 1997 Page 4 F21PG10Page 128
_
F5M0100GEMe
tric
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
137/146
DATE : DEC 1997 Page 5 F21PG10Page 129
_
F5M0100GEMe
tric
LFE SELECTION MODE
It indicates if the Landing Field Elevation data comes either from the FMGESor the landing elevation selector. It also provides the LFE source status.Nothing is displayed when the LDG ELEV selector is completely faulty orduring manual pressure regulation.The LFE selection indication is also displayed on the CRUISE ECAM page.
LFE VALUE
The Landing Field Elevation value is provided by the FMGES in normalcondition.Nothing is displayed in manual pressure regulation.The LFE value indication is also displayed on the CRUISE ECAM page.
: LFE data is available.
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
138/146
GREEN
: LFE data from FMGES is valid and
LDG ELEV selector set to AUTO.
AMBER
: LFE data from FMGES invalid and
LDG ELEV selector set to AUTO.
GREEN
: LDG ELEV selector set to a value
AMBER
: At least one parameter from CPCs
automatic part is not available.
GREEN
(From FMGES or LDG ELEV selector).
AMBER
: LFE data is not available.
GREEN ZERO
AND CYAN
LETTERS
: LFE from FMGES is invalid, (AUTO in amber)
or LDG ELEV selector is completely faulty.
DATE : DEC 1997 Page 6 F21PG10Page 130
_
F5M0100GEMetric
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
139/146
DATE : DEC 1997 Page 7 F21PG10Page 131
_
F5M0100GEMetric
CABIN PThe needle and the cabin differential pressure value are normally displayed
in green. The
P value can vary from -9.9 to 31.9 by steps of 0.1 PSI, but
the needle can only vary from -0.5 to 10.5 PSI.
The cabin differential pressure is also displayed on the CRUISE ECAM page.
: -0.2 P8.85 PSIDuring final approach the P value and the needle
: -0.2 P 8.85 PSIDuring final approach, the P value and theneedle pulse in green if 1.5 < P < 8.85 PSI.
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
140/146
GREEN NEEDLE
During final approach, the P value and the needlepulse in green if 1.5 8.85 PSI.
AMBER NEEDLE
AND VALUE
: P data is not available.
AMBER
CROSSES
GREEN The pulsing stops when the P drops below 1 PSI.
AMBER
: P < -0.2 PSI orP > 8.85 PSI.
AMBER
:P data is not available.
DATE : DEC 1997 Page 8 F21PG10Page 132
_
F5M0100GEMetric
8/12/2019 TTM GEN FAM 21
141/146
CABIN V/S
on CAB PRESS ECAM page and CRUISE ECAM page during manual
press regulation
The needle and the cabin vertical speed value are normally displayed ingreen. The CAB V/S value can vary from -6350 to 6350 by steps of 50 ft/mn.The needle can only vary from -2250 to 2250 ft/mn. The needle disappears
and the cabin vertical speed value is replaced by amber crosses when thecabin vertical speed data is not available.
on DOOR/OXY ECAM page and CRUISE ECAM page during autopress regulation
GREEN
: 25 CAB V/S 1800 ft/mn.It pulses green when CAB V/S > 1800 ft/mn.
It stops pulsing when the CAB V/S value
drops below 1600 ft/mn.
1800 CAB V/S 25 f /
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
142/146
Nothing is displayed when -25 < CAB V/S < 25 ft/mn or the CAB V/S datais not available.
The cabin vertical speed value is normally displayed in green. It can varyfrom 0 to 6350 by steps of 50 ft/mn.
The cabin vertical speed indication on the DOOR/OXY ECAM page is
displayed in flight from lift up to touch down only.
GREEN NEEDLE
: The CAB V/S value and the needle pulse in green if
CAB V/S < -1800 ft/mn or CAB V/S > 1800 ft/mn.
The pulsing stops when the value drops below
1600 ft/mn or goes above -1600 ft/mn.
AMBER
CROSSES
: CAB V/S data is not available
GREEN
: -1800 CAB V/S -25 ft/mn.It pulses green when CAB V/S < -1800 ft/mn.
It stops pulsing when the CAB V/S value
goes above -1600 ft/mn.
GREEN
: The CAB V/S value pulses in green when
CAB V/S < -1800 ft/mn or CAB V/S > 1800 ft/mn.
It stops pulsing when the value drops
below 1600 ft/mn or goes above -1600 ft/mn.
AMBER: CAB V/S data is not available.
DATE : DEC 1997 Page 10 F21PG10Page 134
_
F5M0100GEMetric
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
143/146
DATE : DEC 1997 Page 11 F21PG10Page 135
_
F5M0100GEM
etric
8/12/2019 TTM GEN FAM 21
144/146
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
145/146
DATE : DEC 1997 Page 13 F21PG10Page 137
_
F5M0100GEM
etric
STUDENT NOTES
21 - AIR CONDITIONING
_A330-300 TECHNICAL TRAINING MANUAL
21 AIR CONDITIONINGGENERAL FAMILIARIZATION COURSE
8/12/2019 TTM GEN FAM 21
146/146
DATE : DEC 1997 Page 14 F21PG10Page 138
_
F5M0100GEM
etric