Prüfbescheinigungnach EN 10204: 2004
Werkszeugnis (2.2) [1] TyptestHersteller: SIEMENS AKTIENGESELLSCHAFT Getestet von / Tested by:
Industry Sector SIEMENS AKTIENGESELLSCHAFT
Drive Technologies Large Drives Industry Sector
I DT LD MF/MOH R&D 3 1
Anschrift: Vogelweiherstr. 1-15 Nádražní 25
D 90441 Nürnberg CZ 78985 Mohelnice
Made in Czech Republic
3~MOT
IEC/EN 60034 200L IP55
Th.Cl. 155(F) -20°C <=TAMB<=40°C
DE 6208 2ZC3
NDE
V Hz A kW PF rpm NOM.EFF IE-CL CL
400 D 50 56,0 30,00 0,84 1470 92,3 IE2 K
690 Y 50 32,5 30,00 0,84 1470 92,3 IE2 K
460 D 60 55,0 34,50 0,85 1770 93,0 IE2 J
460 D 60 48,0 30,00 0,84 1778 93,0 IE2 K
Ständer [4]
Bemess.-
Daten
Mot-
Nr
f
[3]
[Hz]
U
[5]
[V]
I
[6]
[A]
n
[7]
[min-1
]
P1
[9]
[kW]
P2
[8]
[ kW]
cos φ
T
[16]
[Nm]
eta
[17]
[%]
IA/IN
[22]
Tl/TN
[23]
p
[15]
Leerl. [10] 50 400,00 21,34 1500 0,806 0,054 4
60 460,00 19,54 1800 0,927 0,058 4
Last [18] 50 400,00 56,27 1474 32,853 30,000 0,836 194,40 91,97 4
60 460,00 55,27 1772 37,633 34,500 0,846 186,31 92,54 4
60 460,00 48,96 1778 32,460 30,000 0,827 161,13 92,92 4
Anzug [19] 50 400,00 394,50 134,600 0,494 476,10 6,97 2,45 4
60 460,00 408,20 147,300 0,465 461,60 7,32 2,48 4
Kurzschlussläufer [11] Ausführung: IEC/EN 60034; TEST ACC. IEC 60034-2-1 [12]
%PN 25 50 75 100
Input Power [9] P1 kW 8,486 16,408 24,432 32,853
50Hz - partial load values Output Power [8] P2 kW 7,500 15,000 22,500 30,000
Power Factor cos φ - 0,478 0,695 0,792 0,836
Efficiency [17] h % 88,96 92,30 92,58 91,97
U1-V1 0,1769 W
Widerstand zwischen Klemmen [13] V1-W1 0,1769 W bei 18,9 °C
W1-U1 0,1768 W
Prüfung der Isolierung bestanden [14] Kühllufttemperatur max. 40 °C [20]
bzw. nach Leistungsschildangabe [21]
English / Francais / česky [13] Resistance between terminals / Résistance entre bornes / Odpor na svorkách
[1] Test report / Fiche d´essais / Osvědčení o zkoušce [14] Withstand voltage test / Essais de tension de tenue / Zkouška vinutí
[2] Reference / Réference / Objednavatel [15] Number of poles / Nombres des póles / Polarita
[3] Frequency / Fréquence / Kmitočet [16] Torque / Couple / Moment
[4] Stator / Stator / Stator [17] Efficiency / Rendement / Účinnost
[5] Voltage / Tension / Napětí [18] Load / Mesure á..charge / Zátěž
[6] Current / Courant / Proud [19] Locked rotor test / Test en court circuit / Zkouška nakrátko
[7] Speed r.p.m. / Vitesse tr/min / Otáčky [20] Cooling air temperature max...°C / Temp. de l´air de
[8] Output / Puissance nominale / Výkon refroifdissement max...°C / Teplota okolí max...°C
[9] Input / Puissance absorbée / Příkon 21] or indication on name plate / ou indiques
[10] No load test / Marche á vide / Naprázdno sur la plaque / pro údaj na výkonovém štítku
[11] Squirrel-cage rotor / [22] Starting current related to rated current / courant rotor bloqué en
Rotor en court-circuit / Rotor nakrátko
[12] According to standard / [23] Starting torque related to rated torque / couple rotor bloqué en proportion
Exécution selon prescription/Provedení de couple assigné / Poměr momentu záběrového k momentu jmenovitému
Datum:gez. Jiří Rajčula
Load
I DT LD P R&D 2
Mohelnice8.1.2014
Bearing
6208 2ZC3
Leistung
1CV2205B
T12200L-672,685,686-4 5 889 18705 50 034
H
DV erstellt, ohne Unterschrift gültig
1LE15012AB534