1
L Air Injection Depth (S = 4*L) Air Delivery Pressure (L + S) Tank Water Level Air Flowrate (Q Air = 0.275*Q f ) Screen Elevation is 8” below Tank Water Level H Filter ID Flowrate (Q f , gpm) Outlet Pipe Size (in) Flow Velocity (ft/s) Filter Height (in) Air Lift Requirement (in) Air Injection Depth (in) Air Delivery Pressure (in) Air Flowrate (Q Air , scfm) (D down ) (D up ) (V down ) (V up ) (H) (L) (S) (L+S) PG-6000 45 (2) x 3 (2) x 3 1.02 1.02 47 8 32 40 12 PG-12000 90 (2) x 4 (2) x 4 0.97 0.97 54 8 32 40 25 Q f D down D up Airlift Pump p PolyGeyser ® Bead Filter TYPICAL AIRLIFT PUMP CONFIGURATION FOR THE POLYGEYSER ® 6OOO and 12OOO AST Aquaculture Systems Technologies, LLC 2120 North 3rd Street Baton Rouge, LA 70802 www.as�ilters.com info@as�ilters.com Phone: 504.837.5575 T oll-Free:800.939.3659 Fax: 504.837.5585

TYPICAL AIRLIFT PUMP CONFIGURATION FOR THE …

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

LL

AAiirr IInnjjeeccttiioonn DDeepptthh((SS == 44**LL))

AAiirr DDeelliivveerryy PPrreessssuurree((LL ++ SS))

TTaannkkWWaatteerr LLeevveell

AAiirr FFlloowwrraattee ((QQAAiirr == 00..227755**QQff))

SSccrreeeenn EElleevvaattiioonniiss 88”” bbeellooww TTaannkkWWaatteerr LLeevveell

HH

Filter ID

Flowrate (Qf, gpm)

Outlet Pipe Size (in)

FlowVelocity (ft/s)

FilterHeight (in)

Air Lift Requirement (in)

Air Injection Depth (in)

Air DeliveryPressure (in) Air Flowrate

(QAir, scfm) (Ddown) (Dup) (Vdown) (Vup) (H) (L) (S) (L+S)

PG-6000 45 (2) x 3 (2) x 3 1.02 1.02 47 8 32 40 12 PG-12000 90 (2) x 4 (2) x 4 0.97 0.97 54 8 32 40 25

QQff

DDddoowwnn

DDuupp

AAiirrlliifftt PPuummpp

PPoollyyGGeeyysseerr®® BBeeaadd FFiilltteerr

TYPICAL AIRLIFT PUMP CONFIGURATION FOR THE POLYGEYSER® 6OOO and 12OOO

AST Aquaculture Systems Technologies, LLC2120 North 3rd StreetBaton Rouge, LA 70802www.as�ilters.com

info@as�ilters.comPhone: 504.837.5575

Toll-Free:800.939.3659Fax: 504.837.5585