View
31
Download
0
Category
Preview:
DESCRIPTION
RAV MAMAD (RM). A Universal Modular (Assemble & Dismantle) Indoor Protection System. info@defensetechs.com www.defensetechs.com. Registered Patent. The Present Situation & Problem - PowerPoint PPT Presentation
Citation preview
RAV MAMAD (RM)A Universal Modular (Assemble & Dismantle)
Indoor Protection System.
info@defensetechs.com www.defensetechs.com
The Present Situation & ProblemThere is a ballistic threat of high-trajectory weapons aimed towards 1/3
of the Israeli CIVILIAN population (north and south).
The present ALERT time does provide enough time for the citizens to
reach a protected shelter.
Building a “Protected Room” (MAMAD) is not practical in many of the
apartments and houses.
Registered Patent
info@defensetechs.com www.defensetechs.com
A concrete ceiling structure hit by a rocket
Registered Patent
info@defensetechs.com www.defensetechs.com
info@defensetechs.com www.defensetechs.com
A tiled roof and a Ravitz ceiling house hit by a rocket.
The Solution
An indoor protection system created
by a metal protective layer, installed
and adjusted to the ceiling and wall of
a pre-chosen room (or space).
A defense room plan (ceiling + wall)
info@defensetechs.com www.defensetechs.com
The standard RM withstands a direct hit of a “Quassam II” light missile and the “Katyusha” 122mm and 120mm Mortar.
The protection level can be upgraded according to the threat defined by an additional layer and without the need to dismantle the base.
info@defensetechs.com www.defensetechs.com
The Protective SystemThe ceiling and “threatened” walls inside the pre-chosen room are covered with constructive steel panels, combined to create a protective layer against shrapnel and shock waves.
The panels are manually inserted and installed upon supportive hidden columns in the corners of the room.
By this action, it is not required to reinforce the complete structure of the house / apartment, as the weight is diverted to the floor and at its strongest points.
info@defensetechs.com www.defensetechs.com
The Protective System
Combining the panels, creates a strong but flexible (to a limit) continuous surface, enabling it to resist and block the explosion effects.
info@defensetechs.com www.defensetechs.com
Plaster cover
Supporting Steel columns
Protected room by “Rav mamad”
Protection element
info@defensetechs.com www.defensetechs.com
Protection element
A wall protection option
Protected room by “rav mamad”
info@defensetechs.com www.defensetechs.com
IMPS SIMULATIONS
info@defensetechs.com www.defensetechs.com
1.Original Condition
IMPS SIMULATIONS
info@defensetechs.com www.defensetechs.com
2 .Wall Protection
IMPS SIMULATIONS
info@defensetechs.com www.defensetechs.com
IMPS SIMULATIONS
3 .IMPS Ceiling Supporting Steminfo@defensetechs.com www.defensetechs.com
IMPS SIMULATIONS
5 .IMPS Ceilinginfo@defensetechs.com www.defensetechs.com
5 .Paneling Walls & Columns With Chemistry
IMPS SIMULATIONS
info@defensetechs.com www.defensetechs.com
6 .Complete IMPS- Inside View
IMPS SIMULATIONS
info@defensetechs.com www.defensetechs.com
Advantages Creates a possibility to form a protected zone in “unqualified” for reinforcement (construction) structures .Modular, suitable for any room in any structure.
License free Quick installation ( 1 day for protection, 1 day for finishes).Upgrading ability (threat related).
Cost Effective
info@defensetechs.com www.defensetechs.com
From the report made for the test of durability of protection layers for indoor room and spaces towards direct rocket hit.
“...on January 8th, 2007 a test was conducted for checking the
durability of IMPS – indoor modular protection system, towards
a direct rocket hit…”
“…the test was done at the Rosh HaAyin Quarries for the Mifram
co. by Tamar co. and supervised by YY (Yaacov Yerushalmi)
info@defensetechs.com www.defensetechs.com
“… the 2 explosions results showed success for the IMPS
as the system did not collapse, did not tear and no
fragments or shrapnel penetrated beyond the
“… the test included 2 static operational demolitions of rocket simulator
containers.
1. 5Kg TNT upon 8cm thick concrete surface.
2. 7.5Kg TNT upon 20CM cement blocks
info@defensetechs.com www.defensetechs.com