53_1000832_02_WWNCardFRU_v600

Embed Size (px)

Citation preview

  • 7/25/2019 53_1000832_02_WWNCardFRU_v600

    1/8

  • 7/25/2019 53_1000832_02_WWNCardFRU_v600

    2/8

    2 of 8 WWN Card Replacement Procedure

    53-1000832-02

    Corporate HeadquartersBrocade Communications Systems, Inc.

    1745 Technology Drive

    San Jose, CA 95110

    Tel: 1-408-333-8000

    Fax: 1-408-333-8101

    Email: [email protected]

    Asia-Pacific HeadquartersBrocade Communications Singapore Pte. Ltd.

    9 Raffles Place

    #59-02 Republic Plaza 1

    Singapore 048619

    Tel: +65-6538-4700

    Fax: +65-6538-0302

    Email: [email protected]

    European and Latin American Headquarters

    Brocade Communications Switzerland Srl

    Centre Swissair

    Tour A - 2me tage

    29, Route de l'Aroport

    Case Postale 105

    CH-1215 Genve 15

    SwitzerlandTel: +41 22 799 56 40

    Fax: +41 22 799 56 41

    Email: [email protected]

    Document Title Publication

    Number

    Summary of Changes Publication Date

  • 7/25/2019 53_1000832_02_WWNCardFRU_v600

    3/8

    WWN Card Replacement Procedure

    3 of 853-1000832-02

  • 7/25/2019 53_1000832_02_WWNCardFRU_v600

    4/8

    4 of 8 WWN Card Replacement Procedure

    53-1000832-02

    3

    1

    2

  • 7/25/2019 53_1000832_02_WWNCardFRU_v600

    5/8

    WWN Card Replacement Procedure

    5 of 853-1000832-02

    switch:admin> frureplace wwn

    This is the WWN card hot swap interface.

    Continuing from this point will require

    the whole process to be completed.

    If this process is not complete due to a

    power cycle, or CP failover, please follow

    the recovery procedure in

    Core Switch WWN Card Removal and

    Replacement document.

    Do you wish to continue [y/n]?

    Backing up WWN card data, please wait about 25 seconds for further instruction.

    Please install the new FRU now.

    If this session lost for any reason, please re-enter the frureplace command and

    follow the instructions to complete the operation.

    Please enter the word continue after the new WWN card has been installed:

    , [EM-1050], ,, INFO,

    , FRU WWN # removal detected.

    , [EM-1049], ,, INFO,

    , FRU WWN # insertion detected.

    , [EM-1004], ,, CRITICAL,

    , WWN # failed to power on

    , [EM-1034], ,, ERROR,

    , WWN # set to faulty, rc=

  • 7/25/2019 53_1000832_02_WWNCardFRU_v600

    6/8

    6 of 8 WWN Card Replacement Procedure

    53-1000832-02

  • 7/25/2019 53_1000832_02_WWNCardFRU_v600

    7/8

    WWN Card Replacement Procedure

    7 of 853-1000832-02

    Please enter the word continue after the new WWN card has been installed: continue

    Restoring the information to the replacement FRU now, please wait about 20 seconds to

    complete

    Verifying the replacement FRU now...WWN card hot swap is now complete.

    FRU replacement completed successfully!

  • 7/25/2019 53_1000832_02_WWNCardFRU_v600

    8/8

    8 of 8 WWN Card Replacement Procedure

    53-1000832-02