CE EMC Conformity Test
Report No: BWS-17-EC-0010 CE EMC Conformity Test
Page Number : Page 2 of 40
BWS TECH Inc. Issue Date : 17 January 2017
TABLE OF CONTENTS
1. General Description of EUT 3
2. General Information of Test 4-6
3.1 Conducted Emission Tests 7-10
3.2 Radiated Emission Tests 11-13
3.3 Radiated Electromagnetic disturbance Test 14-18
3.4 Power Frequency Harmonics and Flicker Emission Tests 19-24
3.5 Electrostatic Discharge Immunity Test 25-27
3.6 Radiated, radio-frequency, electromagnetic field immunity test 28-29
3.7 Electrical fast transient/burst immunity test 30-31
3.8 Surge immunity test 32-33
3.9 Conducted immunity test 34-35
3.10 Voltage Dips and Short interruptions immunity test 36-37
4. EUT Photographs 38-40
CE EMC Conformity Test
Report No: BWS-17-EC-0010 CE EMC Conformity Test
Page Number : Page 3 of 40
BWS TECH Inc. Issue Date : 17 January 2017
1. General Description of EUT
1.1 Applicant
Company Name : SoluM Co., Ltd.
Address : 150, Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16674
Republic of Korea
Contact Person : Ki-Dong, Lee
E mail : [email protected]
Phone / FAX : TEL : +82-31-8006-7677 FAX : -
1.2 Manufacturer
Company Name : SoluM Co., Ltd.
Address : 150, Maeyeong-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 16674
Republic of Korea
Contact Person : Ki-Dong, Lee
E mail : [email protected]
Phone / FAX : TEL : +82-31-8006-7677 FAX : -
1.3 Basic Description of EUT
Trade Name :
Product Name : LED CONVERTER
Model Name : SLB450N801N1A
ADD Model : SLB400N701N1A
Serial Number : Prototype
Test Voltage : AC 230 V, 50 Hz
Rating : Input: AC (200 - 250) V, (50/60) Hz, MAX 0.45 A, 47 W
Output: DC (23 - 50) V, 0.8 A, 40 W
CE EMC Conformity Test
Report No: BWS-17-EC-0010 CE EMC Conformity Test
Page Number : Page 4 of 40
BWS TECH Inc. Issue Date : 17 January 2017
2. General Information of Test
2.1 Test Facility This test was carried out by BWS TECH Inc.
Test Site Location : 23, Gokhyeon-ro 480 Beon-gil, Mohyeon-myeon, Cheoin-gu, Yongin-si,
Gyeonggi-do 449-853, Korea
TEL : 82-31-333-5997
FAX : 82-31-333-0017
2.2 Standard for Methods of Measurement
Basic Standard Description Test Result
EN 55015:2013
Limits and methods of measurement of radio
disturbance characteristics of electrical lighting and
similar equipment
Pass Fail
EN 61547:2009 Equipment for general lighting purposes — EMC
immunity requirements Pass Fail
EN 61000-3-2:2014 Mains harmonics equipment up to 16A. Pass Fail
EN 61000-3-3:2013 Voltage fluctuations equipment up to 16A. Pass Fail
EN 61000-4-2:2009 Testing and measurement techniques.
Electrostatic discharge immunity test. Pass Fail
EN 61000-4-3:2006+A2:2010 Testing and measurement techniques.
Radiated Immunity. Pass Fail
EN 61000-4-4:2012 Testing and measurement techniques.
Electrical fast transient/burst immunity test. Pass Fail
EN 61000-4-5:2014 Testing and measurement techniques.
Surge immunity test. Pass Fail
EN 61000-4-6:2014
Testing and measurement techniques.
Immunity to conducted disturbances induced by
radio frequency fields.
Pass Fail
EN 61000-4-8:2010 Testing and measurement techniques.
Power frequency magnetic field Immunity Test. N/A #Note 1
EN 61000-4-11:2004
Testing and measurement techniques.
Voltage Dips, Short Interruptions and Voltage
Variations Immunity Tests.
Pass Fail
#Note 1. This test was excluded, because EUT was not containing any devices susceptible to magnetic fields.
2.3 Description of EUT Modification
- N/A
2.4 Variations covered by this report - N/A
2.5 Additional information related to Testing Test results apply only to the particular sample tested and functionality described in this test report. This report may be
reproduced in full. Partial reproduction may only be made with the written permission of the BWS Tech Inc.
CE EMC Conformity Test
Report No: BWS-17-EC-0010 CE EMC Conformity Test
Page Number : Page 5 of 40
BWS TECH Inc. Issue Date : 17 January 2017
2.6 Model Difference
Basic Model is SLB450N801N1A
- Variant Model is SLB400N701N1A
Additional models derived by the buyer’s request.
2.7 Test Conditions
EUT Operating Mode EUT was tested according to the following operation modes provided by the specifications given by the manufacturer, and
reported the worst emissions.
Operation Modes Worst Case Mode
Normal Operation Mode
Performance Criteria
A) Performance Criterion A
During the test, no change of the luminous intensity shall be observed and the regulating control, if any, shall
operate during the test as intended.
B) Performance Criterion B
During the test, the luminous intensity may change to any value. After the test, the luminous intensity shall
be restored to its initial value within 1 min. Regulating controls need not function during the test, but after
the test the mode of the control shall be the same as before the test provided that during the test no mode
changing commands were given.
C) Performance Criterion C
During and after the test, any change of the luminous intensity is allowed and the lamp(s) may be
extinguished. After the test, within 30 min, all functions shall return to normal, if necessary by temporary
interruption of the mains supply and/or operating the regulating control
CE EMC Conformity Test
Report No: BWS-17-EC-0010 CE EMC Conformity Test
Page Number : Page 6 of 40
BWS TECH Inc. Issue Date : 17 January 2017
Test System layout on EUT and peripherals
Interface cable Power cable
2.8 Description of Test System (EMI and EMS)
Type of Peripheral Equipment Used:
Description Model Name Serial No. Manufacturer
EUT SLB450N801N1A Prototype SoluM Co., Ltd.
LED N/A N/A N/A
JIG N/A N/A N/A
Type of Cables Used:
Device from I/O Port Device to I/O Port Length(m) Type of Shield
EUT
AC IN Power Socket - 1.0 Unshielded
DC OUT LED DC IN 0.3 Unshielded
JIG
- EUT - Direct -
- LED - Direct -
JIG
LED
EUT
CE EMC Conformity Test
Report No: BWS-17-EC-0010 CE EMC Conformity Test
Page Number : Page 7 of 40
BWS TECH Inc. Issue Date : 17 January 2017
3.1 Conducted Emission Tests
Conducted Emissions were measured from 9 kHz to 150 kHz with a bandwidth of 200 Hz, 150 kHz to 30 MHz with a
bandwidth of 9 kHz on the 230 V AC power and return leads of the EUT according to the methods defined in
European Standard EN 55015:2013 Clause 8. The EUT was placed on a nonmetallic stand in a shielded room 0.8
meters above the ground plane as shown in section 3.1.5. The interface cables and equipment positioning were varied
within limits of reasonable applications to determine the position producing maximum conducted emissions.
3.1.1 Test Condition
Frequency Range of Test : 9 kHz to 30 MHz
Test Standard : EN 55015:2013
Test Date : 12 January 2017
Temperature/Humidity : 16 C / 36 % R.H.
3.1.2 Test Standard
Item Frequency Range
(MHz)
Limit dB(uV)
Quasi-Peak Average-Peak
Main Terminal
0.009 - 0.05 110 -
0.05 - 0.15 90 to 80 -
0.15 - 0.5 66 to 56 56 to 46
0.5 - 5.0 56 46
5.0 - 30 60 50
Item Frequency Range
(MHz)
Limit dB(uV)
Quasi-Peak Average-Peak
Control Terminal 0.15 - 0.5 84 to 74 74 to 64
0.5 - 30 74 64
3.1.3 Test Equipment List
Equipment Type Model Manufacture Serial No Cal Due Date Use
EMI Test Receiver ESPI ROHDE & SCHWARZ 100063 01. 05. 2018
LISN LN2-16N EMCIS LN16004 03. 24. 2017
CE EMC Conformity Test
Report No: BWS-17-EC-0010 CE EMC Conformity Test
Page Number : Page 8 of 40
BWS TECH Inc. Issue Date : 17 January 2017
3.1.4 Test Result of Conducted Emission
Conducted Emission Test Results: PASS
Test data sheets follow.
Conducted Emission Test Data
EUT : SLB450N801N1A
Input Voltage : AC 230 V, 50 Hz
Test Mode : L1
CE EMC Conformity Test
Report No: BWS-17-EC-0010 CE EMC Conformity Test
Page Number : Page 9 of 40
BWS TECH Inc. Issue Date : 17 January 2017
Conducted Emission Test Results: PASS
Test data sheets follow.
Conducted Emission Test Data
Notes
1. Margin = Limit - Emission Level
2. All modes of operation were investigated and the worst-case emissions are reported.
See the plots in next pages.
3. Measurement uncertainty estimated at 3.72 dB.
The measurement uncertainty is given with a confidence of 95 % with the coverage factor, k = 2.
EUT : SLB450N801N1A
Input Voltage : AC 230 V, 50 Hz
Test Mode : N
CE EMC Conformity Test
Report No: BWS-17-EC-0010 CE EMC Conformity Test
Page Number : Page 10 of 40
BWS TECH Inc. Issue Date : 17 January 2017
3.1.5 Photographs of Conducted Emission Test Configuration
[Conducted Emission Test-Main Terminals]
CE EMC Conformity Test
Report No: BWS-17-EC-0010 CE EMC Conformity Test
Page Number : Page 11 of 40
BWS TECH Inc. Issue Date : 17 January 2017
3.2 Radiated Emission Tests
Radiated emissions form 30 MHz to 300 MHz were measured with a bandwidth of 120 kHz according to the methods
defines in EN 55015:2013. The EUT was placed on a nonmetallic stand in the 10 m chamber, 0.8 meter above the ground
plane, as shown in section 3.2.5. The interface cables and equipment positions were varied within limits of reasonable
applications to determine the positions producing maximum radiated emissions.
3.2.1 Test Condition
Frequency Range of Test : 30 MHz to 300 MHz
Test Standard : EN 55015:2013
Test Date : 12 January 2017
Temperature/Humidity : 19 C / 24 % R.H.
3.2.2 Test Standard
Frequency Range
(MHz)
Limit (dBuV)
Quasi-Peak
30 ~ 230 30
230 ~ 300 37
3.2.3 Test Equipment List
Equipment Type Model Manufacture Serial No Cal Due Date Use
Bilog Antenna VULB 9160 SCHWARZBECK 9160-3052 10. 06. 2017
EMI Test Receiver ESR ROHDE & SCHWARZ 101320 03. 25. 2017
RF AMPLFIER MPA-10-40 RF Bay 21163921 10. 10. 2017
Antenna Mast ( 4 m) AM 4.0 MATURO AM4.0/225/17
240915 N/A
Positioner Controller CO2000 MATURO NCU/459/172
40915 N/A
CE EMC Conformity Test
Report No: BWS-17-EC-0010 CE EMC Conformity Test
Page Number : Page 12 of 40
BWS TECH Inc. Issue Date : 17 January 2017
3.2.4 Test Result of Radiated Emission
Radiated Emission Test Results : PASS
Test data sheets follow.
Radiated Emission Test Data
Notes 1. * H : Horizontal polarization , ** V : Vertical polarization
2. Margin value = Emission Level – Limit (Quasi-Peak)
3. Corr. = Correction factor (Antenna factor + Cable loss – AMP gain)
4. Measurement uncertainty estimated at 5.49 dB.
The measurement uncertainty is given with a confidence of 95 % with the coverage factor, k = 2.
EUT : SLB450N801N1A
Test distance : 10 m
CE EMC Conformity Test
Report No: BWS-17-EC-0010 CE EMC Conformity Test
Page Number : Page 13 of 40
BWS TECH Inc. Issue Date : 17 January 2017
3.2.5 Photographs of Radiated Emission Test Configuration
[Radiated Emission Test]
CE EMC Conformity Test
Report No: BWS-17-EC-0010 CE EMC Conformity Test
Page Number : Page 14 of 40
BWS TECH Inc. Issue Date : 17 January 2017
3.3 Radiated Electromagnetic disturbance Test
Radiated emissions form 9 kHz to 30 MHz were measured with a bandwidth of 200 Hz, 9 kHz according to the
methods defines in EN 55015:2013. The EUT was placed on a nonmetallic stand as shown in section 3.3.5.
3.3.1 Test Condition
Frequency Range of Test : 9 kHz to 30 MHz
Test Standard : EN 55015:2013
Test Date : 12 January 2017
Loop Antenna Size : 2 m
Temperature/Humidity : 16 C / 36 % R.H.
3.3.2 Test Standard
Frequency Range
(MHz)
Limit (dBuV)
Quasi-Peak Average-Peak
0.009 - 0.07 88 N/A
0.07 - 0.15 88 to 58 N/A
0.15 - 3.0 58 to 26 N/A
3.0 - 30 22 N/A
3.3.3 Test Equipment List
Equipment Type Model Manufacture Serial No Cal Due Date Use
Loop Antenna HXYZ 9170 SCHWARZBECK HXYZ9170-215 N/A
EMI Test Receiver ESPI ROHDE & SCHWARZ 100063 01. 05. 2018
CE EMC Conformity Test
Report No: BWS-17-EC-0010 CE EMC Conformity Test
Page Number : Page 15 of 40
BWS TECH Inc. Issue Date : 17 January 2017
3.3.4 Test Result of Radiated Emission
Radiated Electromagnetic disturbance Test Results: PASS
Test data sheets follow.
Radiated Electromagnetic disturbance Test Data
EUT : SLB450N801N1A
Loop Antenna Size : 2 m
Test mode : X-axis
CE EMC Conformity Test
Report No: BWS-17-EC-0010 CE EMC Conformity Test
Page Number : Page 16 of 40
BWS TECH Inc. Issue Date : 17 January 2017
Radiated Electromagnetic disturbance Test Results: PASS
Test data sheets follow.
Radiated Electromagnetic disturbance Test Data
EUT : SLB450N801N1A
Loop Antenna Size : 2 m
Test mode : Y-axis
CE EMC Conformity Test
Report No: BWS-17-EC-0010 CE EMC Conformity Test
Page Number : Page 17 of 40
BWS TECH Inc. Issue Date : 17 January 2017
Radiated Electromagnetic disturbance Test Results: PASS
Test data sheets follow.
Radiated Electromagnetic disturbance Test Data
Notes 1. Margin value = Limit - Emission Level
2. All other emissions not reported were more than 25 dB below the permitted limit.
3. Measurement uncertainty estimated at 2.99 dB.
The measurement uncertainty is given with a confidence of 95 % with the coverage factor, k = 2.
EUT : SLB450N801N1A
Loop Antenna Size : 2 m
Test mode : Z-axis
CE EMC Conformity Test
Report No: BWS-17-EC-0010 CE EMC Conformity Test
Page Number : Page 18 of 40
BWS TECH Inc. Issue Date : 17 January 2017
3.3.5 Photographs of Radiated Electromagnetic disturbance Test.
[Radiated Electromagnetic disturbance Test]
CE EMC Conformity Test
Report No: BWS-17-EC-0010 CE EMC Conformity Test
Page Number : Page 19 of 40
BWS TECH Inc. Issue Date : 17 January 2017
3.4 Power Frequency Harmonics and Flicker Emission Tests
3.4.1 Test Procedure
Power Frequency Harmonics Tests :
The measured values of the harmonics components of the input current, including line current and neutral current, shall
be compared with the limits given in Clause 7 of EN 61000-3-2:2014
Flicker Emission Tests :
The total impedance of the test circuit, excluding the appliance under test, but including the internal impedance of the
supply source, shall be equal to the reference impedance. The stability and tolerance of the reference impedance shall be
adequate to ensure that the overall accuracy of 8 % is achieved during the whole assessment procedure.
3.4.2 Test Condition
EUT : SLB450N801N1A
Test Standard : EN 61000-3-2:2014
EN 61000-3-3:2013
Test Date : 12 January 2017
Device Class : C
Temperature/Humidity : 21 C / 36 % R.H.
3.4.3 Test Equipment List
Equipment Type Model Manufacture Serial No Cal Due Date Use
Compliance Test System PACS-1 California Instruments 71980 N/A
AC Power Source 5001IX California Instruments 54549 01. 05. 2018
3.4.4 Test Result of Power Frequency Harmonics and Flicker Emission Tests
Power Frequency Harmonics : PASS
Flicker Emission Tests : PASS
CE EMC Conformity Test
Report No: BWS-17-EC-0010 CE EMC Conformity Test
Page Number : Page 20 of 40
BWS TECH Inc. Issue Date : 17 January 2017
Harmonics – Class-C
EUT: SLB450N801N1A Tested by: BWS TECH Inc.
Test category: Class-C (European limits) Test Margin: 100
Test duration (min): 3
Customer: SoluM Co., Ltd.
Test Result: Pass Source qualification: Normal
Current & voltage waveforms
- 0 . 6
- 0 . 4
- 0 . 2
0 . 0
0 . 2
0 . 4
0 . 6
- 3 0 0
- 2 0 0
- 1 0 0
0
1 0 0
2 0 0
3 0 0
Cu
rr
en
t
(A
mp
s)
Vo
lta
ge
(
Vo
lts
)
Harmonics and Class C limit line European Limits
0 . 0 0
0 . 0 1
0 . 0 2
0 . 0 3
0 . 0 4
0 . 0 5
0 . 0 6
0 . 0 7
0 . 0 8
0 . 0 9
Cu
rr
en
t
RM
S(
Am
ps
)
H a r m o n i c #4 8 1 2 1 6 2 0 2 4 2 8 3 2 3 6 4 0
Test result: Pass Worst harmonics H7-49.42% of 100% limit, H7-33.61% of 150% limit.
CE EMC Conformity Test
Report No: BWS-17-EC-0010 CE EMC Conformity Test
Page Number : Page 21 of 40
BWS TECH Inc. Issue Date : 17 January 2017
Current Test Result Summary (Run time)
EUT: SLB450N801N1A Tested by: BWS TECH Inc.
Test category: Class-C (European limits) Test Margin: 100
Test duration (min): 3
Customer: SoluM Co., Ltd.
Test Result: Pass Source qualification: Normal
THC(A): 0.01 I-THD(%): 6.21 POHC(A): 0.000 POHC Limit(A): 0.019
Highest parameter values during test:
V_RMS (Volts): 229.77 Frequency(Hz): 50.00
I_Peak (Amps): 0.325 I_RMS (Amps): 0.200
I_Fund (Amps): 0.199 Crest Factor: 1.622
Power (Watts): 45.2 Power Factor: 0.981
Harm# Harms(avg) 100%Limit %of Limit Harms(max) 150%Limit %of Limit Status
2 0.000 0.004 0.0 0.000 0.006 0.00 Pass
3 0.008 0.059 12.8 0.008 0.088 8.73 Pass
4 0.000
5 0.007 0.020 34.8 0.007 0.030 23.64 Pass
6 0.000
7 0.007 0.014 49.4 0.007 0.021 33.61 Pass
8 0.000
9 0.002 0.010 0.0 0.002 0.015 0.00 Pass
10 0.000
11 0.004 0.006 0.0 0.004 0.009 0.00 Pass
12 0.000
13 0.002 0.006 0.0 0.002 0.009 0.00 Pass
14 0.000
15 0.001 0.006 0.0 0.001 0.009 0.00 Pass
16 0.000
17 0.002 0.006 0.0 0.002 0.009 0.00 Pass
18 0.000
19 0.001 0.006 0.0 0.001 0.009 0.00 Pass
20 0.000
21 0.001 0.006 0.0 0.001 0.009 0.00 Pass
22 0.000
23 0.001 0.006 0.0 0.001 0.009 0.00 Pass
24 0.000
25 0.000 0.006 0.0 0.001 0.009 0.00 Pass
26 0.000
27 0.000 0.006 0.0 0.000 0.009 0.00 Pass
28 0.000
29 0.001 0.006 0.0 0.001 0.009 0.00 Pass
30 0.000
31 0.000 0.006 0.0 0.000 0.009 0.00 Pass
32 0.000
33 0.000 0.006 0.0 0.000 0.009 0.00 Pass
34 0.000
35 0.000 0.006 0.0 0.000 0.009 0.00 Pass
36 0.000
37 0.000 0.006 0.0 0.000 0.009 0.00 Pass
38 0.000
39 0.000 0.006 0.0 0.001 0.009 0.00 Pass
40 0.000 Note: Dynamic limits were applied for this test. The highest harmonics values in the above table may not occur at the same window as the maximum
harmonics/limit ratio.
CE EMC Conformity Test
Report No: BWS-17-EC-0010 CE EMC Conformity Test
Page Number : Page 22 of 40
BWS TECH Inc. Issue Date : 17 January 2017
Voltage Source Verification Data (Run time)
EUT: SLB450N801N1A Tested by: BWS TECH Inc.
Test category: Class-C (European limits) Test Margin: 100
Test duration (min): 3
Customer: SoluM Co., Ltd.
Test Result: Pass Source qualification: Normal
Highest parameter values during test:
Voltage (Vrms): 229.77 Frequency(Hz): 50.00
I_Peak (Amps): 0.325 I_RMS (Amps): 0.200
I_Fund (Amps): 0.199 Crest Factor: 1.622
Power (Watts): 45.2 Power Factor: 0.981
Harm# Harmonics V-rms Limit V-rms % of Limit Status
2 0.099 0.459 21.63 OK
3 0.500 2.068 24.18 OK
4 0.025 0.459 5.43 OK
5 0.034 0.919 3.71 OK
6 0.021 0.459 4.58 OK
7 0.026 0.689 3.78 OK
8 0.014 0.459 2.94 OK
9 0.024 0.459 5.21 OK
10 0.012 0.459 2.61 OK
11 0.013 0.230 5.69 OK
12 0.019 0.230 8.40 OK
13 0.013 0.230 5.50 OK
14 0.009 0.230 4.03 OK
15 0.010 0.230 4.24 OK
16 0.011 0.230 4.67 OK
17 0.019 0.230 8.43 OK
18 0.015 0.230 6.42 OK
19 0.015 0.230 6.36 OK
20 0.014 0.230 5.96 OK
21 0.010 0.230 4.31 OK
22 0.008 0.230 3.40 OK
23 0.007 0.230 3.23 OK
24 0.006 0.230 2.69 OK
25 0.010 0.230 4.54 OK
26 0.008 0.230 3.51 OK
27 0.006 0.230 2.78 OK
28 0.006 0.230 2.53 OK
29 0.006 0.230 2.68 OK
30 0.007 0.230 3.09 OK
31 0.006 0.230 2.60 OK
32 0.005 0.230 2.33 OK
33 0.006 0.230 2.67 OK
34 0.003 0.230 1.16 OK
35 0.003 0.230 1.49 OK
36 0.005 0.230 1.97 OK
37 0.005 0.230 2.30 OK
38 0.003 0.230 1.45 OK
39 0.004 0.230 1.93 OK
40 0.009 0.230 3.92 OK
CE EMC Conformity Test
Report No: BWS-17-EC-0010 CE EMC Conformity Test
Page Number : Page 23 of 40
BWS TECH Inc. Issue Date : 17 January 2017
Flicker Test Summary per EN/IEC61000-3-3 (Run time)
EUT: SLB450N801N1A Tested by: BWS TECH Inc.
Test category: All parameters (European limits) Test Margin: 100
Test duration (min): 10
Customer: SoluM Co., Ltd.
Test Result: Pass Status: Test Completed
Psti and limit line European Limits
0 . 2 5
0 . 5 0
0 . 7 5
1 . 0 0
Ps
t
14
:1
8:
54
Parameter values recorded during the test:
Vrms at the end of test (Volt): 229.67
Highest dt (%): 0.00 Test limit (%): 3.30 Pass
Time(mS) > dt: 0.0 Test limit (mS): 500.0 Pass
Highest dc (%): 0.00 Test limit (%): 3.30 Pass
Highest dmax (%): 0.00 Test limit (%): 4.00 Pass
Highest Pst (10 min. period): 0.064 Test limit: 1.000 Pass
CE EMC Conformity Test
Report No: BWS-17-EC-0010 CE EMC Conformity Test
Page Number : Page 24 of 40
BWS TECH Inc. Issue Date : 17 January 2017
3.4.5 Photographs of Power Frequency Harmonics and Flicker Emission Tests Configuration.
[Power Frequency Harmonics and Flicker Emission Tests- Harmonics]
[Power Frequency Harmonics and Flicker Emission Tests- Flicker]
CE EMC Conformity Test
Report No: BWS-17-EC-0010 CE EMC Conformity Test
Page Number : Page 25 of 40
BWS TECH Inc. Issue Date : 17 January 2017
In order to minimize the impact of environmental parameters on test results, the tests shall be carried out in climatic and electromagnetic reference conditions as specified in EN 61547:2009. The test programs and software shall be chosen so as to exercise all normal modes of operation of the EUT. The use of special exercising software is encouraged, but permitted only where it can be shown that the EUT is being comprehensively exercised. The testing shall be performed by direct and indirect application of discharges to the EUT according to a test plan.
3.5.1 Test Condition
EUT : SLB450N801N1A
Test Standard : EN 61547:2009
Test Method : EN 61000-4-2:2009
Test Date : 12 January 2017
Test Voltage : Contact 4 kV, Air (2,4,8) kV
Performance criterion : B
Temperature/Humidity/Pressure : 19 C / 31 % R.H. / 100.5 kPa
3.5.2 Test Equipment List
Equipment Type Model Manufacture Serial No Cal Due Date Use
ESD Simulator EDS30V 3CTEST ES0121601 04. 01. 2017
3.5.3 Test Result of Electrostatic Discharge Immunity Test
3.5 Electrostatic Discharge Immunity Test
Electrostatic Discharge Immunity Test : PASS
The equipment meets the requirements.
CE EMC Conformity Test
Report No: BWS-17-EC-0010 CE EMC Conformity Test
Page Number : Page 26 of 40
BWS TECH Inc. Issue Date : 17 January 2017
Test data sheet follows.
Test Point
Discharge Type
CD=Contact
AD=Air
Test
Voltage(kV) Tested No Observation Result
VCP CD 4 kV Each 10 times Normal PASS (A)
HCP CD 4 kV Each 10 times Normal PASS (A)
EUT Case AD (2,4,8) kV Each 10 times Normal PASS (A)
[Test Point] AD CD
Front
Rear
Left
Right
Remarks 1. The primary functions as described below were fully functional during and after test.
- Normal Operation Mode
2. The direct contact discharge test was excluded because there is no applicable surface on EUT.
CE EMC Conformity Test
Report No: BWS-17-EC-0010 CE EMC Conformity Test
Page Number : Page 27 of 40
BWS TECH Inc. Issue Date : 17 January 2017
3.5.4 Photographs of Electrostatic Discharge Immunity Test Configuration
[Electrostatic Discharge Immunity Test]
CE EMC Conformity Test
Report No: BWS-17-EC-0010 CE EMC Conformity Test
Page Number : Page 28 of 40
BWS TECH Inc. Issue Date : 17 January 2017
3.6 Radiated, radio-frequency, electromagnetic field immunity test
Tests were conducted in accordance with EN 61547:2009 over the frequency range of 80 MHz to 1 000 MHz. The transmitting antenna was located 3 meters from the EUT at a height of 1 meter above the floor. Front, sides and back of the EUT were exposed to a uniform field of 3 V/m using both horizontal and vertical antenna polarizations.
3.6.1 Test Condition
EUT : SLB450N801N1A
Test Standard : EN 61547:2009
Test Method : EN 61000-4-3:2006+A2:2010
Test Date : 12 January 2017
Test field strength (V/m) : 3 V/m
Performance criterion : A
Temperature/Humidity/Pressure : 21 C / 32 % R.H. / 100.5 kPa
3.6.2 Test Equipment List
Equipment Type Model Manufacture Serial No Cal Due Date Use
Signal Generator SME06 ROHDE & SCHWARZ 838529/090 06. 08. 2017
RF Power Amplifier ITA0300KL-500 Infinitech N/A 06. 22. 2017
RF Power Amplifier ITA0750KL-500 Infinitech N/A 06. 22. 2017
Log periodic Antenna K9128 Airlinklab 2016-001 N/A
3.6.3 Test Result of Radiated, radio-frequency, electromagnetic field immunity test
Electromagnetic field immunity test : PASS
The equipment meets the requirements.
CE EMC Conformity Test
Report No: BWS-17-EC-0010 CE EMC Conformity Test
Page Number : Page 29 of 40
BWS TECH Inc. Issue Date : 17 January 2017
Test data sheet follows.
Frequency
Range
(MHz)
Position
(Angle)
Antenna
Polarity
Field
Strength
(V/m)
Modulation Result
80 - 1 000 Front Vertical 3 80 % AM (1 kHz) PASS (A)
80 - 1 000 Rear Vertical 3 80 % AM (1 kHz) PASS (A)
80 - 1 000 Right Vertical 3 80 % AM (1 kHz) PASS (A)
80 - 1 000 Left Vertical 3 80 % AM (1 kHz) PASS (A)
80 - 1 000 Front Horizontal 3 80 % AM (1 kHz) PASS (A)
80 - 1 000 Rear Horizontal 3 80 % AM (1 kHz) PASS (A)
80 - 1 000 Right Horizontal 3 80 % AM (1 kHz) PASS (A)
80 - 1 000 Left Horizontal 3 80 % AM (1 kHz) PASS (A)
Remarks 1. The primary functions as described below were fully functional during and after test.
- Normal Operation Mode
3.6.4 Photographs of Radiated, radio-frequency, electromagnetic field immunity test Configuration
[Radiated, radio-frequency, electromagnetic field immunity test]
CE EMC Conformity Test
Report No: BWS-17-EC-0010 CE EMC Conformity Test
Page Number : Page 30 of 40
BWS TECH Inc. Issue Date : 17 January 2017
3.7 Electrical fast transient/burst immunity test
Tests were conducted in accordance with EN 61547:2009. Tests were performed to 1 kV to AC power lines.
3.7.1 Test Condition
EUT : SLB450N801N1A
Test Standard : EN 61547:2009
Test Method : EN 61000-4-4:2012
Test Date : 12 January 2017
Test Voltage : 1 kV (power lines)
Performance criterion : B
Temperature/Humidity/Pressure : 19 C / 31 % R.H. / 100.5 kPa
3.7.2 Test Equipment List
Equipment Type Model Manufacture Serial No Cal Due Date Use
Compact Immunity Simulator CCS600 3CTEST ES0801543 09. 10. 2017
3.7.3 Test Result of Electrical fast transient/burst immunity test
Electrical fast transient/burst immunity test : PASS
The equipment meets the requirements.
CE EMC Conformity Test
Report No: BWS-17-EC-0010 CE EMC Conformity Test
Page Number : Page 31 of 40
BWS TECH Inc. Issue Date : 17 January 2017
Test data sheet follows.
Line Voltage Coupling Inject Time
(sec) Result
L1-N 1 kV Direct 120 PASS (A)
Remarks 1. The primary functions as described below were fully functional during and after test.
- Normal Operation Mode
2. PE port test was excluded because there was no PE port on the power for the test.
3.7.4 Photographs of Electrical fast transient/burst immunity test Configuration
[Electrical fast transient/burst immunity test]
CE EMC Conformity Test
Report No: BWS-17-EC-0010 CE EMC Conformity Test
Page Number : Page 32 of 40
BWS TECH Inc. Issue Date : 17 January 2017
3.8 Surge immunity test
Tests were conducted in accordance with EN 61547:2009. Tests were performed to 1.0 kV to AC Line to Line and 2.0 kV to Line to Ground.
3.8.1 Test Condition
EUT : SLB450N801N1A
Test Standard : EN 61547:2009
Test Method : EN 61000-4-5:2014
EUT Input : AC 230 V, 50 Hz
Test Date : 12 January 2017
Test Voltage : 1.0 kV (Line to Line), 2.0 kV (Line to Ground)
Performance criterion : B
Temperature/Humidity/Pressure : 19 C / 31 % R.H. / 100.5 kPa
Test Voltage
Characteristics
Test levels
Device
Self-ballasted lamps and
semi-luminaires
Luminaries and independent auxiliaries
Input Power
≤ 25 W > 25 W
Wave-shape data 1.2/50 µS 1.2/50 µS 1.2/50 µS
Test levels Line to Line 0.5 kV 0.5 kV 1.0 kV
Line to Ground 1.0 kV 1.0 kV 2.0 kV
3.8.2 Test Equipment List
Equipment Type Model Manufacture Serial No Cal Due Date Use
Compact Immunity Simulator CCS600 3CTEST ES0801543 09. 10. 2017
3.8.3 Test Result of Surge immunity test
Surge immunity test : PASS
The equipment meets the requirements.
CE EMC Conformity Test
Report No: BWS-17-EC-0010 CE EMC Conformity Test
Page Number : Page 33 of 40
BWS TECH Inc. Issue Date : 17 January 2017
Test data sheet follows.
Line Voltage
(kV) Coupling Phase(Degree)
Inject
(count - min) Result
L1-N (0.5, 1.0) kV 18 F 90, 270 5 times - 5 min PASS (A)
Remarks 1. The primary functions as described below were fully functional during and after test.
- Normal Operation Mode
2. PE port test was excluded because there was no PE port on the power for the test.
3. The input power of EUT is over 25 W.
3.8.4 Photographs of Surge immunity test Configuration
[Surge immunity test]
CE EMC Conformity Test
Report No: BWS-17-EC-0010 CE EMC Conformity Test
Page Number : Page 34 of 40
BWS TECH Inc. Issue Date : 17 January 2017
3.9 Conducted immunity test
Tests were conducted in accordance with EN 61547:2009. Over the frequency range of 150 kHz to 80 MHz. Tests
were performed at 3 V on power line.
3.9.1 Test Condition
EUT : SLB450N801N1A
Test Standard : EN 61547:2009
Test Method EN 61000-4-6:2014
Test Date : 12 January 2017
Test Voltage : 3 V
Performance criterion : A
Temperature/Humidity/Pressure : 19 C / 31 % R.H. / 100.5 kPa
3.9.2 Test Equipment List
Equipment Type Model Manufacture Serial No Cal Due Date Use
RF Power Amplifier 75A250 AmplifierReseach 0325567 02. 28. 2017
Signal Generator SMT02 ROHDE & SCHWARZ DE27053 08. 09. 2017
Attenuator 100W6dB N/A N/A 03. 25. 2017
CDN CDN M250E COM POWER CORPORATION 511237 07. 21. 2017
3.9.3 Test Result of Conducted immunity test
Conducted immunity test : PASS
The equipment meets the requirements.
CE EMC Conformity Test
Report No: BWS-17-EC-0010 CE EMC Conformity Test
Page Number : Page 35 of 40
BWS TECH Inc. Issue Date : 17 January 2017
Test data sheet follows.
Test port Frequency
(MHz) Coupling Dwell time Modulation Step Size Result
Power 0.15 – 80 CDN (M2) 1 s 80 % AM (1 kHz) 1.0 % PASS (A)
Remarks 1. The primary functions as described below were fully functional during and after test.
- Normal Operation Mode
3.9.4 Photographs of Conducted immunity test Configuration
[Conducted immunity test]
CE EMC Conformity Test
Report No: BWS-17-EC-0010 CE EMC Conformity Test
Page Number : Page 36 of 40
BWS TECH Inc. Issue Date : 17 January 2017
3.10 Voltage Dips and Short interruptions immunity test
Voltage variations tests were conducted in accordance with EN 61547:2009.
3.10.1 Test Condition
EUT : SLB450N801N1A
Test Standard : EN 61547:2009
Test Method : EN 61000-4-11:2004
Test Date : 12 January 2017
Voltage Dip : 70 % (10 periods)
Short interruptions : 0 % (0.5 periods)
Performance criterion : 70 % (10 periods) - C, 0 % (0.5 periods) - B
Temperature/Humidity/Pressure : 19 C / 31 % R.H. / 100.5 kPa
3.10.2 Test Equipment List
Equipment Type Model Manufacture Serial No Cal Due Date Use
Compact Immunity Simulator CCS600 3CTEST ES0801543 03. 24. 2017
3.10.3 Test Result of Voltage Dips and Short interruptions immunity test
Voltage Dips and Short interruptions immunity test : PASS
The equipment meets the requirements.
CE EMC Conformity Test
Report No: BWS-17-EC-0010 CE EMC Conformity Test
Page Number : Page 37 of 40
BWS TECH Inc. Issue Date : 17 January 2017
Test data sheet follows.
Test voltage level
% Number of periods
Angle
( ) Criteria Result
70 10 0, 180 C PASS (B)
0 0.5 0, 180 B PASS (A)
Remarks
1. EUT was turned off at the test of Short interruptions in 70 % (10 periods), but it was fully functional after test.
2. Except for the test of Short interruptions in 70 % (10 periods), the primary functions as described below were fully functional
during and after test.
3.10.4 Photographs of Voltage Dips and Short interruptions immunity test Configuration
[Voltage Dips and Short interruptions immunity test]
CE EMC Conformity Test
Report No: BWS-17-EC-0010 CE EMC Conformity Test
Page Number : Page 38 of 40
BWS TECH Inc. Issue Date : 17 January 2017
4. EUT PHOTOGRAPHS
[Front of EUT]
[Rear of EUT]
CE EMC Conformity Test
Report No: BWS-17-EC-0010 CE EMC Conformity Test
Page Number : Page 39 of 40
BWS TECH Inc. Issue Date : 17 January 2017
[Front of PCB board]
[Rear of PCB board]
CE EMC Conformity Test
Report No: BWS-17-EC-0010 CE EMC Conformity Test
Page Number : Page 40 of 40
BWS TECH Inc. Issue Date : 17 January 2017
[Multi model label]